This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

Similar documents
SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Engine Does Not Start or Is Hard to Start Cause of Trouble. 1. Open the drain screw, and check Fuel not supplied (1) Fuel tank empty

Lumitester PD-30. Instruction Manual. Table of Contents

SECTION 6 CORROSION PREVENTION AND APPEARANCE CARE. Corrosion prevention and appearance care

Instruction Manual LAMI CORPORATION INC.

ARTICLE BEGINNING SERVICE PRECAUTIONS

Sediment strainer (Type Y)

1. Inspection and Maintenance

Section 10 Chapter 17

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

2003 FORESTER SERVICE MANUAL QUICK REFERENCE INDEX

/ Air Line Kit AL - M1203BS2 / OPERATION MANUAL. P1 - P8 / English P11 - P18 OM-K0652

Service Bulletin Published by Sudden Service, Inc.

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

6 Litre Oil-Less Air Compressor

COOLING SYSTEM ON-VEHICLE INSPECTION CO 1

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

DIGITAL TEMPERATURE CONTROL

ENGINE COOLING SYSTEM

Routine Compressor Maintenance

2010 Toyota Prius Repair Manual

2004 IMPREZA SERVICE MANUAL QUICK REFERENCE INDEX

VAL6 KBE5S. Service Manual

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

GROUP CONTENTS GENERAL DESCRIPTION RADIATOR SPECIAL TOOL THERMOSTAT ENGINE COOLING DIAGNOSIS...

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT...

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

ILLUSTRATION ILLUSTRATION

Diaphragm Valves Type 15

PowerLink GW series Eddy Current Dynamometer User Manual

¼ to 1HP Chiller Service Manual

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

M-3025CB-AV Fuel Pump

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

FPU SYSTEMS OPERATION MANUAL BOH PORTABLE DRAWER MODULE (PDM) (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units CHAPTER 4

SPV Series Slides OPERATING MANUAL. Table of contents 1 Introduction Compliance with the EC Directives Names of parts...

CENTERING DEVICE. Model CE-1 OPERATOR S MANUAL

TURBOCHARGER SYSTEM TURBOCHARGER TC 1

Requests for Daily Care and Maintenance

Cooling System. Table of Contents

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

IGNITION COIL - 2.4L SPARK PLUG

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

Hydraulic Immediate Need Power Pack

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

HEAVY DUTY POWER RELAYS FEATURES

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

ENGINE SPECIFICATIONS

Lubrication & Maintenance Schedule

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

TC Series Cooling Systems

REMOVAL & INSTALLATION

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Table of Contents. 4. Before a New Turbocharger is Installed

HEAVY DUTY ONBOARD AIR SYSTEM

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT...

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

Butterfly Valve Type 58 (PDCPD)

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Water pump Owner's Manual

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

ENGINE AND EMISSION CONTROL

Maintenance Adjustments

For Pneumatic Piping/Fittings & Tubing Prior to Use

MEDIUM DUTY ONBOARD AIR SYSTEM

CHAPTER 7 VAGABOND S HANDBOOK

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Operators Manual. Recirculating Chiller /06/08

Diaphragm Valve Type 72

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

CARBURETOR - HITACHI 2-BBL

SERIES 600 OMNI DIRECTIONAL PARTITIONS

NHRA RACING Ford Stock Replacement 735 CFM Class Legal Carburetor P/N

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Servo drive alarm. PLC error. l Door sensor alarm. -To put the safety cover on the right position. -To open the safety cover

Multistage Air Filtration Systems Instruction Manual

2001 LEGACY SERVICE MANUAL QUICK REFERENCE INDEX

Battery Safety Instructions 4 Garden Fountain Parts List 7 Step1: Battery Installation 8 Step 2: Setting Up Your Fountain 11

Operations and Service Manual. X30208 Load Bank

.$/,7*76(7$ /HDI %ORZHU USER MANUAL

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

Two Hand Control Valve

TURQUOISE STROKE SWITCHES

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

NILFISK BA 500 Service Manual

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Pure sine wave charger inverter Product Manual

Transcription:

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber Chapter 5 Inspection and maintenance This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber. Note <Operations to be performed by the customer> Use the chamber according to the methods indicated in the operation manual and perform independent periodic inspections. Perform inspections before and after operation. Replace the consumables and regular replacement parts indicated by ESPEC. 5.1 Inspection and maintenance items 5.1.1 List of consumables and regular replacement parts The following parts must be replaced periodically to maintain the performance and functionality of the chamber. Promptly replace them at the specified interval if not sooner. Maintenance service is also provided by ESPEC. Contact your distributor or ESPEC to request the maintenance and inspection service and components. Table 5.1 List of consumables Part Oil filter element Air filter element Recommended replacement period 10,000 h 10,000 h ESPEC CORP. 71

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance Table 5.2 List of regular replacement parts Part Test area door packing Damper packing Silicon cord heater (for damper) Silicon cord heater (for drain) Door drive belt Door switch Temperature sensor Temperature switch (OHP3 (TS1), TS2) Air cylinder (for door) (including installation brackets) Air cylinder (for damper) Solenoid valve (for air circuit) AC fan motor (electrical compartment exhaust fan) Recommended replacement period 7 years Replacement method and approximation When the packing is deformed or damaged (hot or cold air leaks from the door) When the packing is deformed or damaged (hot or cold air leaks from the damper) When condensation or icing occurs due to insufficient heating provided by the silicon cord heater When condensation or icing occurs due to insufficient heating provided by the silicon cord heater When the door drive belt is damaged and the door is not driven sufficiently When door malfunctions occur When chamber errors occur due to temperature sensor disconnections or connection failures (temperature control unit sensor disconnection error) When chamber errors occur due to temperature switch malfunctions (external overheating/overcooling) When air leaks from the air cylinder or when strange sounds or door malfunctions occur When air leaks from the air cylinder or when strange sounds or damper malfunctions occur When strange sounds are emitted from the solenoid valve or when solenoid valve malfunctions cause door or damper malfunctions When strange sounds are emitted from the fan motor or when fan motor malfunctions occur * The above recommended replacement periods are the recommended periods and do not indicate exactly when replacements will be needed. The actual values will depend on the usage conditions. If anything strange is detected during daily checks or maintenance, replace the part. 72 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.1.2 Inspection items For a description of each item, see "5.2 Inspection". If the inspection items listed below do not operate properly, contact your distributor or ESPEC. Table 5.3 Inspection items Operation inspection item Circuit breaker (main power switch) trip test Overheat protector operation test Overcool protector operation test Water suspension relay operation test (water-cooled chamber) Inspection period Once a month Before long-time continuous operation Before starting operation Before unattended operation Before starting operation Before unattended operation Once every 3 months 5.1.3 Maintenance items For a description of each item, see "5.3 Maintenance". Table 5.4 Maintenance items Maintenance item Water circuit leakage inspection Test area cleaning Electrical/machinery compartment cleaning Strainer element cleaning and replacement (water-cooled chamber) Cleaning the cooling water circuit Fuse replacement Air filter cleaning and replacement Oil filter cleaning and replacement Door drive belt check and replacement Refrigerator oil check Compressor pressure inspection Cleaning the air cooled condenser (air-cooled chamber) Once a day Maintenance period Before starting operation Once a year Once every 3 months (cleaning) or when the high stage high pressure (G 11 ) read on the gauge exceeds 2 MPa (20 kg/ cm2 ) Once a year Whenever a fuse blows Once a month (cleaning) Once every 10,000 hours (element replacement) Once a month (cleaning) Once every 10,000 hours (element replacement) Once a year (inspection) Once every 7 years (replacement) Once every 6 months Once a month Once a month * For the arrangements to perform when you will not use the chamber for a long time, see "5.3.11 Arrangement before long periods of disuse". ESPEC CORP. 73

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 5.1.4 Adjustment list Adjustments are required to maintain chamber functionality and performance. When the adjustment period is reached, contact your distributor or ESPEC. Table 5.5 Adjustment list Adjustment item Air pressure switch Regulator pressure Damper opening/closing speed Test area door opening/closing speed (optional automatic door) Adjustment period Once every 2 years Once every 2 years Once every 2 years Once every 2 years 74 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.2 Inspection 5.2.1 Circuit breaker (main power switch) trip test Test the circuit breaker (main power switch) operation once a month or before starting long-term continuous operation. With the circuit breaker (main power switch) on, gently press the test button. Pressing the test button should cause the circuit breaker (main power switch) lever to lower. 200, 220 VAC chambers 380, 400, 415 VAC chambers Models TSA-43EL TSA-73EL, 73ESA, 73ESW TSA-103EL, 103ES Test button Test button Test button TSA-73EH TSA-203EL, 203ES TSA-303EL Fig 5.1 Test button position Reference When the circuit breaker (main power switch) lever lowers, it stops at a point halfway between on and off. To turn on the power, lower the lever to the off position, and then raise it to the on position. 5.2.2 Overheat protector operation test Before starting chamber operation, test the operation of the overheat protector. 1) Check that the circuit breaker (main power switch) is on. 2) Press the power switch on the instrumentation panel to turn on the chamber. 3) Press the operating status box to switch to the operation screen. Next, press the START TEST button under <Operation Mode>, and then press Yes on the screen that is displayed to confirm your selection. The test will start. Perform the overheat protector operation test in high temperature exposure mode. 4) Set the overheat protector to a temperature that is approximately 5 C lower than the test area temperature. If the overheat protector is operating normally, a buzzer will sound and an alarm will appear on the instrumentation screen. If no alarm is generated, the chamber is malfunctioning. Contact your distributor or ESPEC. 5) To cancel the buzzer, press the Buzzer Stop button. 6) Turn off the instrumentation panel power switch to return the setting to the previous temperature. ESPEC CORP. 75

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 5.2.3 Overcool protector trip test Before starting chamber operation, test the operation of the overcool protector. 1) Check that the circuit breaker (main power switch) is on. 2) Press the power switch on the instrumentation panel to turn on the chamber. 3) Press the operating status box to switch to the operation screen. Next, press the START TEST button under <Operation Mode>, and then press Yes on the screen that is displayed to confirm your selection. The test will start. Perform the overcool protector operation test in low temperature exposure mode (a temperature of -10 C or lower). 4) Set the overcool protector to a temperature that is approximately 5 C higher than the test area temperature. If the overcool protector is operating normally, a buzzer will sound and an alarm will appear on the instrumentation screen. If no alarm is generated, the chamber is malfunctioning. Contact your distributor or ESPEC. 5) To cancel the buzzer, press the Buzzer Stop button. 6) Turn off the instrumentation panel power switch to return the setting to the previous temperature. 5.2.4 Water suspension relay operation test Once every three months, test the operation of the water suspension relay. 1) Check that the circuit breaker (main power switch) is on. 2) Press the power switch on the instrumentation panel to turn on the chamber. 3) Press the operating status box to switch to the operation screen. Next, press the SETUP ONLY button under <Operation Mode>, and then press Yes on the screen that is displayed to confirm your selection. The chamber starts performing setup operations. 4) Close the primary water supply valve. If the water suspension relay is operating normally, a buzzer sounds and a screen displaying an alarm appears on the instrumentation. If no alarm is generated, the chamber is malfunctioning. Contact your distributor or ESPEC. 5) To cancel the buzzer, press the Buzzer Stop button. 6) Turn off the instrumentation panel power switch, and then open the primary water supply valve. 76 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3 Maintenance 5.3.1 Cleaning the air-cooled condenser (air-cooled chamber only) WARNING Be sure to turn off the circuit breaker (main power switch) before detaching the rear panels. The machinery compartment contains rotating and moving parts such as the fan. Detaching the rear panels with the circuit breaker (main power switch) on may lead to injury. CAUTION Never touch the condenser fins with bare hands. The fins may cut your hands. The air-cooled condenser on the rear of the chamber may be clogged if dust or similar substances affix to the fins. In this situation, sufficient cooled air cannot enter into the condenser. This reduces the performance and activates the safety devices to disable operations. In addition, the condenser operating for a long time in this manner may lead to refrigerator malfunctions. Clean the condenser fins once per month. 1) Turn the circuit breaker (main power switch) off to stop the chamber, and then detach the rear panels. 2) Vacuum up the dust on the slits of the rear panels and on the condenser fins with a vacuum cleaner. If dust cannot be removed, pour water on the condenser to clean it. Rear panels Air-cooled condenser inlet slits (The condenser is installed behind the rear panels.) Fig. 5.2 Cleaning the slits of the rear panels and the condenser fins 3) Reattach the rear panels where they were. Note Do not bend the condenser fins. If the condenser fins are bent, heat cannot be normally exchanged and the performance of the chamber is reduced. ESPEC CORP. 77

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance Energy Saving Advice CHECK! As a guideline, clean the condenser fins once a month. Regular cleaning of the fins can prevent lowered refrigeration capacity and reduce the load on the exhaust fan. 5.3.2 Water circuit leakage inspection Water leaking from the water circuit can adversely affect the installation area and cause problems. Check for water leaks once a day. 1) Check the drain pipe connection ports for leaks. 2) Check the connecting parts of the strainer and nipple for leaks. Nipple Strainer Fig. 5.3 Water leak inspection Note If you find a water leak, identify and repair the leaking location. 78 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3.3 Test area cleaning Dust and impurities that adhere to the test area floor and walls can be carried throughout the system by air currents and eventually stick to heaters, air circulators, and other components. This can lead to problems and distort test results. Clean the test area before and after tests. 1) Open the test area door. 2) Wipe the test area with a soft cloth. 3) Close the test area door. 5.3.4 Electrical/machinery compartment cleaning Dust deposits in the electrical or machinery compartment can lead to malfunctions. Clean these compartments once a year. 1) Check that the circuit breaker (main power switch) is off. 2) Open the electrical compartment door and the machinery compartment door. 3) Use a vacuum cleaner or other means to clean out the dust that has accumulated in the electrical compartment and machinery compartment. 4) Close the electrical compartment door and the machinery compartment door. 5.3.5 Strainer element cleaning and replacement Water deposits and foreign matter can accumulate on the strainer element attached to the cooling water supply pipe, which may lead to clogging. In this situation, the amount of water supplied will be insufficient, which may cause the water suspension relay to activate and make chamber operations impossible. Clean or replace the strainer element approximately once every three months. The frequency with which cleaning or replacement is necessary varies depending on the cleanliness of the cooling water, so exercise your own judgment in determining how often this maintenance is required. ESPEC CORP. 79

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance Notice If the cooling water or cooling tower is being shared with a different device, close the valve on the secondary drainage pipe in advance. Back pressure may be applied to the secondary drainage pipe, causing the cooling water to back-flow, which may lead to water leaking from the strainer. Water-cooled condenser Secondary side Drain water Chamber interior Strainer Fig. 5.4 Sharing cooling water or the cleaning tower Cooling tower or other water supply equipment If cooling water remains within the chamber, water may leak from the strainer when the strainer element is replaced. Valve Valve Primary side Water supply 1) Close the primary valve. If the secondary drainage pipe has a valve, close it as well. 2) Place a tray or other appropriate container with which to catch the water under the strainer. 3) Loosen the strainer cap, and then remove the strainer element. Shared water source Chamber Flow of water Strainer element Gasket Cap Fig. 5.5 Removing the strainer element 4) Use a brush or similar tool to clean the strainer element. If you cannot sufficiently clean the strainer element, replace it with a new part. 80 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3.6 Cleaning the cooling water circuit Scale accumulated inside of the piping may decrease the heat exchange capacity, and the high pressure switch may trip as a result. Clean the inside of the piping once a year. Otherwise, too much scale may cause heat exchange (condenser) malfunction and a replacement will be necessary in the worst case. For cleaning, contact your distributor or ESPEC. (Cleaning is subject to billing.) 5.3.7 Fuse replacement Over prolonged testing, fuses can weaken and blow. When a fuse blows, replace it as explained below. Note If the new fuse blows as soon as the power is turned back on, contact your distributor or ESPEC. 1) Check that the circuit breaker (main power switch) is off. 2) Remove the screws from the electrical compartment door, and then open the electrical compartment door. 3) Replace the blown fuse with a new one. <TSA-43EL> F3 F1 TBA MS3 MS2 MS1 TC1 <TSA-73EL, 73ES, 103EL, 103ES> Fuse Fuse capacity F1: 5 A F3: 5 A F3 F1 TBA NF1 MS3 MS1 TC1 ESPEC CORP. 81

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance <TSA-73EH> F3 F1 CP2 PR1 TC1 <TSA-203EL, 203ES, 303EL> Fuse Fuse capacity F1: 5 A F3: 5 A Th2-2 F3 F1 CP2 PR1 TC1 Fig. 5.6 Fuse replacement 4) Close the electrical compartment door. 82 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3.8 Air filter and oil filter cleaning and replacement As dirt, tar, carbon, dust, or other substances accumulate on the air and oil filters of the air circuit, drainage gets obstructed. Incomplete drainage may lead to problems and even breakdowns in the air circuit parts. Clean or replace the air filter and oil filter about once a month. CAUTION Do not remove the bowl guards until the pressure gauge reads 0 MPa. If air remains in the air circuit, the bowl guards can separate from the chamber with sufficient force to injure someone. 1) Check that the circuit breaker (main power switch) is off. 2) Close the primary air supply valve, then disconnect the air supply tube from air supply port at the chamber rear to release air. 3) Open the machinery compartment door. 4) Press on the bowl guard lock, turn it to the mark, and then detach the bowl guard. Pressure gauge Regulator Air filter element Pressure switch Baffle Oil filter element Filter bowl Bowl guard Lock Fig. 5.7 Removing the bowl guards 5) Turn the baffle until it is loose, and then remove the air filter element. Use an M6 box wrench to remove the oil filter element. ESPEC CORP. 83

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 6) Wash the air filter, oil filter bowls, and the air filter element with a neutral detergent, and then rinse these parts clean. 7) Use a soft, dry cloth to blot the moisture on the filter bowls and air filter element. Note Do not wash the parts with synthetic oils (phosphate ester base), organic solvents, or chemicals (thinner, carbon tetrachloride, etc.). Do not expose the parts to direct sunlight. Reference If badly soiled, the oil filter element cannot be reused even if it is washed. In this situation, replace the element. (Replace the element once every 10,000 hours.) 84 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3.9 Door drive belt check Inspect the door drive belt once a year. 1) Check that the circuit breaker (main power switch) is off. 2) Remove the screws that lock the front right and left panels to open them. Power-fail air purge button Front panel Door drive belt Front panel Fig. 5.8 Door drive belt 3) Press the power-fail air purge button in the top left-hand corner of the chamber front. 4) Slide the test area door up and down, checking that there are no cracks in either of the belts. If there are any problems with the belts, contact your distributor or ESPEC. 5) Close the front right and left panels, and then lock them in place with the screws. ESPEC CORP. 85

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 5.3.10 Refrigerator oil check To maintain refrigerator functionality and performance, inspect the refrigerator oil once every 6 months. WARNING Be sure to turn off the circuit breaker (main power switch) before detaching the rear panels. The machinery compartment contains rotating and moving parts such as the fan. Detaching the rear panels with the circuit breaker (main power switch) on may lead to injury. 1) Check that the circuit breaker (main power switch) is off. 2) Detach the rear panels. 3) Use the level gauge at the bottom of the refrigerator to inspect the refrigerator oil. Inspection details The oil level should appear within the gauge. The oil should not be discolored. (The color should not be black.) If there are any problems with the refrigerator oil, contact your distributor or ESPEC. 4) Reattach the rear panels where they were. Level Fig. 5.9 Level gauge 86 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 5.3.11 Arrangement before long periods of disuse If the chamber will not be used for an extended period of time, be sure to perform the steps shown below. Failure to do so may result in inaccurate testing and reduce the operating life of the chamber. Dry the test area (run the chamber). Turn off the circuit breaker (main power switch) and the primary power supply, and then use the circuit breaker handle stopper to prevent accidental operations of the circuit breaker (main power switch). Dry the test area (run the chamber) Operate the chamber to dry out its test area and cold chamber. Periodically dry out the test area and the cold chamber. 1) Check that the circuit breaker (main power switch) is on. 2) Press the power switch on the instrumentation panel to turn on the chamber. 3) Press the operating status box to switch to the operation screen. Next, press the DRY MODE button under <Operation Mode>, and then press Yes on the screen that is displayed to confirm your selection. The chamber starts performing dry operation. 4) The chamber will perform dry operation and will automatically stop when the time set for Dry Time on the Recovery Conditions screen (Chamber setup) elapses. 5) Press the instrumentation panel power switch. Press Yes on the screen that is displayed to confirm your selection. The instrumentation turns off. Turn the power off 1) Turn the circuit breaker (main power switch) off. 2) Prepare the included circuit breaker handle stopper. ESPEC CORP. 87

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 3) Set the circuit breaker handle stopper as shown below. 1 Setting the 200 V, 220 V (TSA-43EL, 73EL, 73ES, 103EL, 103ES) circuit breaker handle stopper Align the protrusion of the circuit breaker handle stopper with the circuit breaker (main power switch) handle. Attach the circuit breaker handle stopper to the circuit breaker (main power switch), and then slide the circuit breaker handle stopper all the way to the back to lock it in place. Attach padlocks. Fig. 5.10 200 V, 220 V type (TSA-43EL, 73EL, 73ES, 103EL, 103ES) 2 Setting the 200 V, 220 V (TSA-73EH, 203EL, 203ES, 303EL) circuit breaker handle stopper In slide mode, set the circuit breaker handle stopper in place on the circuit breaker (main power switch), and then change the circuit breaker handle stopper to lock mode. Attach padlocks. Fig. 5.11 200 V, 220 V type (TSA-73EH, 203EL, 203ES, 303EL) 88 ESPEC CORP.

Basic guide Chapter 5 Inspection and maintenance Air to Air Thermal Shock Chamber 3 Setting the 380 V, 400 V/415 V (all models) circuit breaker handle stopper Padlock Handle Circuit breaker handle stopper Lock plate Attach a padlock. Fig. 5.12 380 V, 400 V/415 V type (all models) 4) Turn off the primary power supply. 5) Close the cooling water supply valve. 6) Turn off the water supply system (cooling tower). Energy Saving Advice CHECK! Turn off the instrumentation panel power switch and the circuit breaker (main power switch) on the chamber. Reduce the standby power. If the chamber will not be used for an extended period of time, turn off the circuit breaker (main power switch) to reduce the standby power. Turn on the circuit breaker (main power switch) one hour before using the chamber. (When the ambient temperature is 20 C.) ESPEC CORP. 89

Air to Air Thermal Shock Chamber Basic guide Chapter 5 Inspection and maintenance 5.3.12 Compressor pressure check Abnormal compressor pressure can lead to the pressure switch tripping and problems with the refrigeration circuit. Check the pressure once a month. 1) Check that the circuit breaker (main power switch) is on. 2) Press the power switch on the instrumentation panel to turn on the chamber. 3) Press the operating status box to switch to the operation screen. Next, press the START TEST or SETUP ONLY button under <Operation Mode>, and then press Yes on the screen that is displayed to confirm your selection. The chamber starts performing the test or setup operations. 4) 30 minutes after starting operation, use the pressure gauge in the machinery compartment to check that the pressure is within the normal range. Table 5.6 Normal pressure ranges Pressure gauge Low stage low pressure Low stage high pressure High stage low pressure High stage high pressure Normal range (MPa) Air-cooled Water-cooled -0.04 to 0.60-0.04 to 0.60 0.40 to 2.10 0.50 to 2.10-0.04 to 0.80-0.04 to 0.70 0.70 to 2.60 1.00 to 2.10 5) Press the STOP button under <Stop Ope.> to stop operation. Note If the pressure value is outside of the normal range, try correcting the problem as explained in "HI STAGE REFRIG. PRESSURE ERR" or "LOW STAGE REFRIG. PRESSURE ERR" of "Table 6.1 List of alarms". 90 ESPEC CORP.