OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

Similar documents
HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Optima ETF-600/ETF-610

Single Handle Faucet, 4 Plate, Ceramic Cartridge, Extended Lever Handle with Pop-Up

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Commercial Products Catalog

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Milano AUTOMATIC FAUCET

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

LIGATURE RESISTANT SENSOR FAUCET

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

ETF-600 Sensor Operated Lavatory Faucet

BASYS Infrared Sensor Activated

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Installation Instructions

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Installation For Service Only

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Electronic Faucet - 591T Series

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

MAC FAUCETS. FA400 Autoluxe Faucets

Installation Instructions

MAC FAUCETS FA400 WALL MOUNT FAUCETS

MAC FAUCETS. FA400 Wall Mount Sensor

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

Installation Instructions

G2 Optima Plus Flushometer

Installation Instructions

Installation Instructions

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Installation Instructions

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION INSTRUCTIONS STUDIO S

SERIN MONOBLOCK LAVATORY FAUCET with

Installation Instructions

Installation Instructions

Installation Instructions

Sloan Automatic Infrared Sensing Faucets

Installation Instructions

Dolphin Blue Infrared Taps

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions Series

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

MAINTENANCE MANUAL DI 16

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

Automatic Sensor Tap Installation Manual

Installation Instructions

G SERIES - E TOUCH MIXER / TAP

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Electronic Hand Washing Faucet

Installation Instructions Series Series

Installation Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

BASYS Infrared Sensor Activated

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

Installation Instructions

Installation Instructions 7024

INSTALLATION INSTRUCTIONS

TAG: Electronic Faucets EC Electronic Sensor Faucet. Architect/Engineering Specifications:

AquaSense TM ZEG Series

Installation Instructions

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Installation Instructions

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Installation Instructions

INSTALLATION INSTRUCTIONS

BC632 / BCL632 BC635 / BC635

IRC urinal flush control valve

Installation Instructions

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Transcription:

Sensor Faucets and Flush Valves OPERATION & MAINTENANCE MANUAL 5000E Series Faucet www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866) 670-5580

Sensor Faucets and Flush Valves 5000E Series U.S. Patent 6192530B1 AC or Battery Powered Sensor Operated Faucet The 5000E Series faucet is an elegant piston operated sensory faucet that provides a vandal resistant, no touch lavatory solution that promotes better hygiene and energy savings. Designed to be easy to install and maintain, all major faucet components are encased above deck, making for easier access. The sensor included in this faucet is self adapting, meaning manual adjustments are not necessary and the innovative sensor placement eliminates ambient reflectivity issues. ADA Compliant. Meets all barrier free codes Conserves water and energy Easily installed in new or retrofit applications Competitively priced for today s commercial market Promotes cleanliness & hygiene Proven Hydrotek craftsmanship and reliability Available in: D H-5000E-LR: Low Lead, AC Powered D HE-5000E-LR: Low Lead, Battery Powered with Enduratek NEW! Features: Proprietary Enduratek energy saving design allows up to 1.5 million on/off cycles Vandal resistant faucet body with chrome plated, solid metal construction Faucet design allows for quick and simple installation. Clam shell design allows for easy above the deck access to all major faucet component parts. Slow closing solenoid valve provides reliable and smooth operation without water hammer. Available in AC powered and battery powered versions. Unique, energy-saving design of electronics and solenoid valve contributes to longer battery life. AC power input cable is armored and vandal resistant (AC powered version). Sensor eye positioning eliminates ambient reflectivity issues. Self-adapting sensor distance adjustment eliminates the need for manual sensor adjustments. 30 second time-out feature prevents accidental sink overflow. Built-in, replaceable filter screen reduces maintenance costs. Low battery indicator light. Unique electronic control module allows for faucet electronic component diagnostics. Standard 0.5 GPM vandal resistant aerator. Single-hole deck mount with optional 4 and 8 cover plate for vandal resistant three point anchoring.

H-5000E (AC Powered) HB-5000E (Battery Powered) HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste 124 Orlando, FL 32807 800.922.9883 (Phone) 866.670.5580 (Fax) www.hydrotekintl.com Hydrotek Automatic Faucets 5000E Series Deck Mounted / Non-mixing Meets ANSI/ASME A112.18.1 M-1989 Operation: 1. A continuous, invisible beam is emitted from the sensor. 2. The faucet is activated by placing hands under the spout within the effective range of the beam. Water starts to flow immediately for as long as the user s hands remain in the sensor range. 3. When hands are removed, the water flow stops. The sensor will automatically reset and be ready for the next user. 4. In the battery powered version, a flashing red light will indicate a low battery condition. Specifications: Faucet Construction:... Metal & chrome plated Control Circuit: Auto. Time-out:... 30 seconds Sensor Range:... Self adapting Shut-off Delay:... 1 second Solenoid Valve:... 6V DC, normally closed Wattage:... 0.2W (idle), 3W (in use) Operating Pressure:... 5 psi to 125 psi Flow Control:... 0.5 GPM Laminar, vandal resistant AC Mode Power Adapter Standard Plug-in:...Input AC 120V 60 Hz (UL/CSA)...Output DC 7.5V, 0.8A/Class 2 Power Cable:...Armored, vandal resistant Optional Multi-Unit Adapter:...Serves up to 8 faucets (UL/CSA)...Input AC 120V, Output DC 7.5V, 3A Battery Mode Battery Powered Models:...(4) AA Alkaline Batteries Enduratek Service Life:...1.5 million on/off cycles, up to 10 years Package Includes: (1) Faucet with sensor/solenoid (1) 7.5V DC plug-in power adaptor (H-5000E & H-5000E-LR Only) (2) Armored steel supply tube with filter (1) Mounting lock nut and washer (1) 0.5 GPM vandal resistant Rosette flow control (4) AA Alkaline batteries (HB-5000E & HB-5000E-LR Only) Dimensions: Base Width (Outside Measurement)...2-3/8 Base Depth... 2-3/8 Faucet Height (Aerator to Base)... 4-7/8 Faucet Height Overall... 6-1/2 Depth (Center of Aerator to Center of Faucet Base)... 4-7/8 Mounting Bolt Length... 2-1/4 Mounting Bolt Size... 1-1/8 Optional Variations and Accessories 1.5 GPM VR Soft Flow or 0.35, 2.2 GPM Laminar Flow Control 4 or 8 Centerset Cover Plate HC-010E Multi-Unit Voltage Adapter (AC Powered Only) HBL-04 Thermostatic Mixing Valve with Checks

H-5000E AC Powered Sensor Operated Mixing Faucet Installation Instructions (AC Powered) 1. Prior to installing this faucet, thoroughly flush all water lines and replace stop washers, if necessary. 2. To ensure proper operation, " DRY TEST " the faucet by plugging the Power Adapter (1) into a wall outlet and connecting the Power Adapter output lead to the faucet Input Wire Lead (12). The faucet should immediately perform a self-adjustment and diagnostic function. If you see the indicator light flash and hear a clicking sound, proceed to the next step. If there is no flash of light or clicking sound, recheck power source and connections. 3. Unplug Power Adapter (1) from the wall outlet. Disconnect the Power Adapter output lead from the faucet s AC Input Lead (12). 4. Rotate the Supply Tube Locking Screw (5) fully clockwise. Insert the end of the Supply Tube (9) (with O-rings) fully into the bottom of the Mounting Rod (4) by twisting and pushing until properly seated. Rotate Supply Tube Locking Screw (5) counter-clockwise to lock the Supply Tube into the Mounting Rod. 5. Attach the faucet s AC Input Lead (12) armored cable bracket to the bottom of the Mounting Rod (4) using the existing Mounting Rod screws. 6. Install In-Line Filter (10) onto stop valve using the Nylon Washer (11). 7. Unscrew the Mounting Nut (8) from the Mounting Rod (4) and completely remove both the Mounting Nut (8) and the Star Locking Washer (7). 8. From above the deck, carefully feed the faucet s AC Input Lead (12), Supply Tube (9), and Mounting Rod (4) into the deck mounting hole and seat the faucet in the correct mounting location. 9. From below the deck, feed the AC Input Lead (12) and Supply Tube (9) through the keyed Star Locking Washer (7) and Mounting Nut (8). Slide the Locking Washer and Mounting Nut up onto the Mounting Rod (4) and tighten Mounting Nut on the Mounting Rod to securely lock faucet to the deck. 10. Connect the Supply Tube (9) to the In-Line Filter compression fitting (10) and securely tighten. 11. Connect the Power Adapter (1) output lead to the faucet s AC Input Lead (12). Plug the Power Adapter into the electrical wall outlet. 12. Turn water on and check for leaks. Place your hands under the faucet spout to activate water flow. Remove hands and water should stop. Model H-5000E Part Number Descriptions 1. Power adapter 7. Star locking washer 2. Flow control 8. Mounting nut 3. Faucet body 9. Supply tube 4. Mounting rod 10. In-line filter 5. Supply tube locking screw 11. Nylon washer 6. Gasket 12. AC input lead HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124 Orlando, FL 32807 1.800.922.9883 (Phone) 1.866.670.5580 (Fax) www.hydrotekintl.com

HB-5000E DC Powered Sensor Operated Mixing Faucet Installation Instructions Model HB-5000E 1. Prior to installing this faucet, thoroughly flush all water lines and replace stop washers, if necessary. 2. To ensure proper operation, " DRY TEST " the faucet by loosening the Cover Screw (7) and removing the Top Cover (1). Loosen the Battery Holder Screws (2) and remove the Battery Holder Cover (3). Insert batteries into the Battery Holder (5) and reinstall the Battery Holder Cover. The faucet should immediately perform a self-adjusting and diagnostic function. If you see the indicator light flash and hear a clicking sound, proceed to the next step. If there is no flash of light or clicking sound, recheck batteries for correct positioning. 3. Remove Battery Holder Cover and batteries. 4. Rotate the Supply Tube Locking Screw (10) fully clockwise. Insert the end of the Supply Tube (14) (with O-rings) fully into the bottom of the Mounting Rod (9) by twisting and pushing until properly seated. Rotate Supply Tube Locking Screw (10) counter-clockwise until the red indicator marking on the Locking Screw is at its closest position to the red indicator marking on the Mounting Rod. This is necessary to ensure that the Supply Tube has been properly locked into the Mounting Rod. 5. Install In-Line Filter (15) onto stop valve using the Nylon Washer (16). 6. Unscrew the Mounting Nut (13) from the Mounting Rod (9) and completely remove both the Mounting Nut (13) and the Star Locking Washer (12). 7. From above the deck, carefully feed the faucet s Supply Tube (14) and Mounting Rod (9) into the deck mounting hole and seat the faucet in the correct mounting location. 8. From below the deck, feed the Supply Tube (14) into the keyed Star Locking Washer (12) and Mounting Nut (13). Slide the Locking Washer and Mounting Nut up onto the Mounting Rod (9) and tighten the Mounting Nut on the Mounting Rod to securely lock the faucet to the deck. 9. Connect the Supply Tube (14) to the In-Line Filter Compression Fitting (15) and securely tighten. 10. Reinstall batteries and secure Battery holder Cover (3) with the Battery Holder Screws (2). 11. Reinstall Top Cover (1) and secure the faucet body with Cover Screw (7). 12. Turn water on and check for leaks. Place your hands under the faucet spout to activate water flow. Remove hands and water should stop. Part Number Descriptions 1. Top cover 9. Mounting rod 2. Battery holder screws (2) 10. Locking screw for supply tube 3. Battery holder cover 11. Rubber gasket 4. AA Alkaline Batteries (4) 12. Star locking washer 5. Battery holder 13. Mounting nut 6. Aerator 14. Supply tube 7. V.R. screw for top cover 15. In-line filter 8. Faucet body 16. Nylon washer HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste. 124 Orlando, FL 32807 1.800.922.9883 (Phone) 1.866.670.5580 (Fax) www.hydrotekintl.com

5000E Series Sensor Operated Mixing Faucet Troubleshooting Guide Normal Operation: When power is connected, the faucet will immediately perform diagnostic function. You will hear a clicking sound and see lights flash. When the user s hands are placed under the spout, the light will flash once and water will start to flow. Water flow will stop when hands are removed. The red indicator light will flash when the batteries are low. Turn the manual handle clockwise to increase temperature and counter-clockwise to decrease. Problem Possible Cause To Diagnose Remedy Faucet will not turn on: Faucet will not shut off, has low glow, or drips: Water not turned on Check water supply Turn water on Power supply failure No light, no clicking: Check batteries Check power adapter Reinstall or replace batteries/ Replace power adapter Low battery Light continues to flash Replace batteries Electronic PCB / Sensor is defective Solenoid valve is clogged In-line filter is clogged Solenoid coil is defective Flow control is clogged No light, no clicking: Reinsert batteries Reattach power adapter Solenoid is clicking but no water is coming out Open clean-out trap and check filter screen Insert new batteries or reattach power adapter. Light blinks but no solenoid is clicking Open flow control device and check Replace electronic PCB Clean solenoid Clean or replace filter screen Replace solenoid coil Celan the flow control device The solenoid valve is normally closed. Turn off water and activate the faucet. If there is a clicking sound, the solenoid valve is dirty. If there is no clicking sound, then check the solenoid valve. If the faucet is dripping, clean the solenoid valve. IMPORTANT: Periodic maintenance is required for smooth and trouble-free operation of this faucet. For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922-9883.

5000E Series Sensor Operated Mixing Faucet Maintenance Tasks HCE-194 Solenoid Valve Assembly Replacement Battery Holder Control Module Body Cover 1. Remove faucet Body Cover. 2. Remove batteries (battery powered faucets) or unplug power adapater (AC powered faucets). 3. Loosen and remove the Battery Holder/Control Module, making sure to disconnect all connectors. 4. Unscrew and remove the Solenoid Coil from the Solenoid Valve Module. 5. Completely loosen the four screws securing the Solenoid Valve Module. List the Solenoid Valve Module from the faucet. 6. Install the new Solenoid Valve Module and reassemble the faucet in reverse order. NOTE: When installing the Solenoid Coil to the Solenoid Valve Module, DO NOT over-tighten. Fit should be snug. Solenoid Coil Solenoid Module CONTROL MODULE (P.C. BOARD) REPLACEMENT 1. Remove faucet Body Cover. 2. Remove batteries (battery powered faucets) or unplug power adapter (AC powered faucets). 3. Unplug the Battery Holder/Control Module connector. 4. Loosen the two screws holding the Battery Holder/ Control Module and remove it. 5. Install the new Battery Holder/Control Module ensuring the sensor eye is fitted correctly to the faucet body. For further questions, please call Hydrotek Technical Support at (800) 922-9883.

5000E Series Sensor Operated Mixing Faucet Assembly Parts r i o e w q t u a s y No Description Part Number 1 Solenoid Module HCE-004 2 Solenoid Coil HCE-019 3 Solenoid Assembly HCE-194 4 Control Module Assembly HCE-018A (AC) HCE-018B (DC) 5 Flexible Supply Tube HCE-026 6 In-Line Filter HC-009A 7 Filter Screen HC-020 8 Aerator Connector HCE-006 9 Copper Supply Tube HCE-016 10 Rubber Gasket HCE-022 11 Mounting Nut & Washer HCE-021 Please visit our website, www.hydrotekintl.com, for our most current Products Pricing Sheet.