AXA DALI P20. DALI Broadcast Controller. Installation Manual

Similar documents
DALI Emergency LED Driver - 350/700/1000mA Constant Current

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

c-go 24V/6A 24V/8A 24V/12A

AUTOMATE AC MECHANICAL LIMIT TUBULAR MOTOR

G+ LOCKSET. User Guide

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

AUTOMATE Li-ion ARC TUBULAR MOTOR

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

DALI 650mA LED Driver

2.0Ah BATTERY INSTRUCTION MANUAL

500 / 630 / 720 / 760 / 800 / 850 / 900

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

PowerPlex 40V MAX Standard Battery Pack/Charger

DIN Rail Power Module

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Residential Energy Storage System SH5K PV ESS

INTECH Micro 2300-RTD6

Domestic Water Supply Pressure Pumps

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

EcoSystemT 5-Series LED Driver ( V~, CE)

AVOUTLET.com SELECTABLE RPM

AUTOMATE FT MOTOR INSTRUCTIONS

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

GSM Series MPPT PV Controller. Version 1.0. Manual

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Residential Energy Storage System SH 5K

KEPCO Will Point You In The Right Direction!

Language specific user manuals are available on

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Sectional and Tilting Door Opener

Language specific user manuals are available on

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

AccuPower AQU126B Installation Instructions

C3 Operating Instructions

GP Dimming Panels 230 Volt (CE)

Adaptive Power Module

Adaptive Power Module

AUTOMATE ARC CORD LIFT MOTORS

OPERATION & MAINTENANCE INSTRUCTIONS

OpenEVSE - 40A Charging Station

Sectional and Tilting Door Opener Installation Instructions and User Guide

TeckNet BLUETEK iep517 Power Bank

Installation and Operation Instructions

Emergency lighting units EM series

THREE-PHASE FOUR-WIRE, CT TYPE, 1.5(6A) User Manual for SGE-353

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

AUTOMATE VT 1.0 ARC VENETIAN BLIND TILT MOTOR

OPERATION & MAINTENANCE INSTRUCTIONS

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

AUTOMATE Li-ion Solar Charging Power Panel

Oscillating Tower Fan with Remote Control

X Cube Lift. Model: XCU 190 XCU 180 Installation Instructions

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

Instruction Manual. Instruction Manual LIFETIME PLU Manufactured and packaged for SRGS PTY LTD ABN CONDITIONAL

Switching DC Power Supply

Air duct switching damper

80W &100W Folding Solar Panel Kit

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Scissor Lift Model : SC60 SC40 Installation Instructions

1000mA - 650mA Phase Dimmable LED Driver

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC DIMMER CONTROLLER BY BROMIC IMPORTANT

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

User Manual. SUN FLUX II Hot Water Controller. Model SEI 02. Off Grid/Hybrid PV Solar Hot Water Controller -1-

PowerPlex 40V Max Standard Battery Pack/Charger

OWNER S MANUAL POWER INVERTER

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Operating instructions EWB 200

INSTALLATION. **Microprocessor Status LED:

System Monitoring SCHOOLMETERBOX AU

AS/NZS AS/NZS

TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE

User Manual. Solar Charge Controller 3KW

3 Uninterruptible Power Systems

230VAC Power Inverter 400W Owner s Manual

Low Frequency Inverter. User Manual

Microcare Inverter Manual

ELECTRICAL DRIVE. Roller blind system. uadro. single buttons. Motors

BLUE 3 INSTALLATION GUIDE

Universal Battery Charger Cat. No.: Instruction Manual

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

650mA Phase Dimmable LED Driver

ABB i-bus KNX DG/S x DALI-Gateway Basic

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Advanced Hybrid Wind / Solar Charge Controller. User Manual

IES GRID FEED-IN LIMITER

Accessories for power generation plants in Italy SMA GRID GATE

MICROCARE 3 PHASE INVERTER MANUAL

PSU EN54-4 Power Supplies

AccuPower AQU128B Installation Instructions

User Manual 1KVA-5KVA INVERTER / CHARGER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

User Manual Solar Charge Controller 3KW

X24 Projector Original Instructions

Transcription:

AXA DALI P20 DALI Broadcast Controller Installation Manual

THE DALI P20 MUST BE INSTALLED BY A LICENSED ELECTRICIAN IMPORTANT INFORMATION ELECTRICIANS MUST READ PRIOR TO INSTALLATION 1) This product must only be installed by persons who are appropriately licensed by the applicable State regulatory body. 2) This product must be connected to circuits that incorporate 10 A rated circuit breaker protection. 3) Hazardous voltage exists at the terminals of this product. Ensure the circuit is isolated before removing this product from the wall or electrical enclosure. 4) Damage caused by incorrect installation, force-majeure, electrical surges, lightning, power grid fluctuations, water or by connection to alternative power supply sources (such as solar inverters, etc.) is not eligible for warranty repair. 5) Appliance not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge. 6) Children should be supervised by a person responsible for their safety to ensure that they do not play with the appliance DEVICE OVERVIEW The DALI P20 is a DALI broadcast controller for control of up to 20 DALI fittings. Its integral DALI power supply means no other hardware is required for this controller to operate. With an input for a movement detector and programmable options for Turn on Level, Sensor mode, Run on Timer and Minimum Level the DALI P20 is not only simple to install and use but also extremely flexible in its functionality. 2

INSTALLATION INSTRUCTIONS Before installing this product read all instructions carefully and please keep this installation manual for future reference. WARNING: To prevent electric shock, please ensure that power is isolated before installation. This product is designed for indoor use only. The DALI P20 wall plate must be surface mounted onto a fully enclosed wall cavity or be installed on a suitable surface mount enclosure. The DALI P20 circuitry must be electrically concealed. Installation must be carried out by a qualified electrician in accordance with National Wiring Regulations and other applicable regulations. Compliance to AS/NZS Standards and Low Voltage Directives may be invalidated if not used or installed according to the published specification. The DALI P20 contains no user serviceable parts and should be returned to the manufacturer for repair. Wall Cut-out Requirements The cut-out required is 63mm (L), 50mm (W), 50mm (D) There are four options for wall mounting of the DALI P20. These are: Plasterboard with C-Clip mounting flange Brick with a mounting block Timber with a mounting block Direct screwing onto a suitable material Wiring Diagram 3

The rear of the DALI P20 has a terminal block that accommodates up to 1.5mm 2 wire for electrical and control cable connection. Terminal Description S Sensor Input (220 240V a.c. Trigger Input) A Electrical Active N Electrical Neutral DA+ DALI Data + DA- DALI Data - 220-240V AC 50HZ, Controller Rating 2Watt. Model Number DALI P20 AXA Design Manufacturer DALI Technical Information Installer technical information for DALI based products: DALI requires 2 wires to connect between devices. These wires are not polarity dependant. These wires are at ELV (Extra Low Voltage) potential and are daisy chained to all devices. Some devices, such as HF ballasts are mains powered, and only provide functional isolation between the mains and the DALI control. This means that DALI control wire must be treated as if it were at mains potential. Cable size DALI Cable Run Length Recommended Minimum DALI Cable Conductor Size Less than 100 Meters 0.5mm² 100 to 150 Meters 0.75mm² More than 150 Meters 1.5mm² More than 300 Meters Not recommended, avoid runs over 300 Meters DALI Standard IEC 62386 PROGRAMMING OPTIONS Option 1: Turn on level Mode 1. 100% (default) Mode 2. Last level Option 2: Sensor mode. Mode 1. Manual on, Auto off (default) Mode 2. Auto on, Auto off Mode 3. Disabled Option 3: Sensor run on time (amount of extra time after no 240 input from sensor) Mode 1. 0 Minutes (default) Mode 2. 15 Minutes Mode 3. 30 Minutes Mode 4. 60 Minutes 4

Changing Programming Options 1. Press and hold the push button for 10 seconds and you're in programming mode. The Blue LED will flash to indicate which programming option you are in and what mode that option is set to. 2. Press the push button to change to the next mode. 3. Rotate the knob to change to the next option. 4. To exit programming press and hold the push button for 10 seconds or wait 30 seconds and it will exit programming automatically. Example Press and hold for 10 seconds.... Option 1 mode 1 Press the push button...... Option 1 mode 2 Rotate the knob...... Option 2 mode 1 Press the push button........ Option 2 mode 2 SPECIFICATIONS Electrical Nominal Operating Voltage Nominal Operating Frequency Maximum Load 220 to 240V AC 50Hz 24VA Maximum Wire Size 1.5mm 2 Environmental Ambient Operating Temperature Range Relative Humidity Altitude Control 0 to 50 o C 5 to 95% non-condensing 0 to 3000m MSL% Load Per DALI ballast 2mA Maximum Number of DALI Ballasts 20 DALI Operating Mode Broadcast DALI Data Encoding Manchester DALI Data Baud Rate 1200 DALI Data Cable Requirement 2 wire double insulated Maximum DALI Cable Length 300m with 1.5mm cable (2V line drop maximum) Physical Product Dimension Installation Cut-out Installation 117mm (L), 73(W), 60mm (D) 63mm (L), 50mm (W), 50mm (D) Indoor Use Only Standard AS/NZS 60335.1:2011(IEC 60335-1 Ed. 5 MOD) including Amendment 1, Including AU variations. 5

CONTACT DETAILS Postal and Delivery Address Smartscape Automation 15 Locust St, The Gap Qld. 4061 Australia Phone +61 (07) 3357 1922 Website Email http://www.ssqld.com.au sales@ssqld.com.au DISCLAIMER Smartscape Automation reserves the right to alter specifications and design without further notice. Smartscape Automation will not be held responsible for the misinterpretation of printed material contained in this manual. Further enquiries should be directed to Smartscape Automation using the listed contact details. 6