Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Similar documents
PDU Input Power Cord. Before installation. Specifications

InfraStruXure PDU Power Cable

Cable Ladders with Troughs and Partitions

Operation and Maintenance

Bottom Hose Kit for the High-Density Cooling Enclosure ARACBH1

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Valve Box Assembly for the High-Density Cooling Enclosure ARACVB1

Addendum. Remote Air-Cooled Condenser

Power Distribution Units

Electrical Installation

Power Distribution Units AP9560 & AP9561

Installation. Symmetra MW. 400 kw 480 V. UPS Summary UPS Summary. Normal Normal X017 X012 X008A X014A X014B X013 X008B X011 X405 X010 X007 X021

Smart-UPS VT kva 208/220 V. Site Preparation and Installation Manual

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Safety and General Information

Earthing Principles. Symmetra PX 250/500 kw

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

Installation. Symmetra MW II kw 480 V. UPS Summary Normal Normal

Symmetra PX with Maintenance Bypass

Installing Power Components

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Quick Connection Panel (QCP) Installation Guide

Symmetra PX kw 208 V. Installation 01/

Technical Specifications. Symmetra PX kw 208 V

3000VA 120/208/230VAC

Single and Parallel Installation

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

POWERPLEX PANELBOARD 1

Section 6 Electric Metering: Residential

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

Precision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL

ANZI Transfer Switch and Generator Wiring Installation Addendum

Service Entrance Methods

Single and Parallel Installation. MGE Galaxy kva 208/220 V

Enterprise Power Protection

Symmetra PX. 250/500 kw 400/480 V Single and Parallel Installation 07/

AIS 5000 UPS kva 480 V. Installation Manual

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

Installation Guide. Marine Filter SURT023M SURT024M

Electric Vehicle Charging Station

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

Pow-R-Line 3E Panelboard

Packing Data Installation Instructions

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

RU SERIES UPGRADE TempAssure Compatible

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

F I R S T! Assembly* 4 Battery systems pull toward you, or 8 battery systems Lift up, both sides with a. Fig. B. *performed by licensed electrician

Enterprise Power Protection

Connecting to DC Power

Company Switch Installation Instructions and User Manual

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

Power and Cooling. Chassis Power System

Custom Product Brochure. Custom Design Engineering Team July 1, 2014

INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

SECTION 300 OVERHEAD SERVICE

Electrically Held to Mechanically Latched Contactor

i-energy i-micro inverter GT260

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

CTFRP Series Power Supplies

OVERHEAD SERVICE. Items to consider

Installing and Removing Power Supplies

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Upgrading the Boxer LAD blower module

Installation and Operation

Explosionproof Protection Simplified

COMMERCIAL QUICK REFERENCE

Backup Generation Application

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Features and Benefits

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK

User s Guide Includes Mounting, Installation, and Product Registration

Condenser Fan Pak Installation and Wiring Guide

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

APC Symmetra RM. Installation Manual

INSTALLATION GUIDE AND USER MANUAL

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Solar Photovoltaic (PV) Installation - Updates

1370 DC Loop Contactors and Lug Kits

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

EXTRA LARGE OUTDOOR HOUSINGS

INSTALLATION GUIDE AND USER MANUAL

Sensor3 Rack (SR3 and HSR3 Series) Installation Manual

Solar Power Installation Application

SED2-BT300-XX-C09 Migration Kits. Product Numbers

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

F485 Communications Converter

Operation. Symmetra PX 48, 96, and 160 kw 400 V 100 kw 208 V

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

Operation. Smart-UPS TM VT Rack-mounted kva 200/208 V

Transcription:

Installation InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD806FK1-M PD806FK1-M-14

Contents Certified Electrician s Instructions... 1 How to Connect Utility Conductors and an Emergency Power Off (EPO) Switch to the 80kW InfraStruXure PDU........................................ 1 Connection to Be Performed by a Licensed Electrician Only!.... 1 Procedures in this instruction sheet........................ 1 Electrical requirements................................... 2 Torque specs and tools required overhead wiring............ 2 Torque specs and tools required underfloor wiring........... 3 Ensure Total Power Off.................................... 3 Attach conduit to the PDU for the conductors................. 4 Install a utility/branch circuit breaker........................ 5 Run input conductors..................................... 5 Connect an Emergency Power Off (EPO) switch............... 8 InfraStruXure PDU 80 kw Installation i

How to Connect Utility Conductors and an Emergency Power Off (EPO) Switch to the 80kW InfraStruXure PDU Connection to Be Performed by a Licensed Electrician Only! Electrical Hazard! The following procedures require a licensed electrician: Connection of utility conductors Installation of an upstream circuit breaker Connection to the Main Input switch, Bypass Input switch, Cross Tie Output, MCCB Subfeed circuit breakers, and branch circuit Wiring under the floor Connection of an EPO switch Procedures in this instruction sheet The procedures in this instruction sheet provide instruction for electricians on how to connect to the main input switch, bypass input switch, cross tie output breaker, MCCB sub-feed circuit breaker, and Emergency Power Off switch. Review the information provided in the InfraStruXure Configure-To-Order (CTO) report and accompanying documentation for instructions specific to your installation, and always follow the NEC and local codes. Before an electrician begins connecting your system, an APC Field Service Engineer must: Position and level the Symmetra PX UPS, InfraStruXure PDU, and Battery Enclosure. Exchange side panels and attach the Symmetra PX UPS, InfraStruXure PDU, and Battery Enclosure. Note: Check for updates to this manual by clicking on the User Manuals link on the Support page of the APC Web site (www.apc.com). In the list of InfraStruXure manuals, look for the latest letter revision (A, B, etc.) of the part number on this manual. InfraStruXure PDU 80kW Installation 1

Electrical requirements 208 Vac 480 Vac 600 Vac Upstream Circuit Breaker 350 A 150 A 125 A Conductors to Main Input With transformer: 3 W + + EC to a suitable grounding electrode ** Switch Without transformer: 4 W + Conductors to Bypass Input Switch Conductors to Cross Tie Output Breaker Conductors to MCCB Subfeed Breaker Max. input conductor size (top entry) 4 W + 4 W + 4 W + 500 kcmil for S5 frame 1/0 AW for S3 frame 1/0 AW for S3 frame Lugs for input conductors (top entry) * Max. input conductor size (bottom entry) 600 kcmil for S5 frame 600 kcmil for S3 frame 600 kcmil for S3 frame Lugs for input conductors (bottom entry) Terminal blocks Terminal blocks Terminal blocks Max. bypass input conductor size (top entry) 500 kcmil for S5 frame 500 kcmil for S5 frame 500 kcmil for S5 frame Lugs for bypass input conductors (top entry) * Max. Cross Tie and MCCB 500 kcmil for S5 frame 500 kcmil for S5 conductors (top entry) frame 500 kcmil for S5 frame Lugs for Cross Tie and MCCB conductors (top entry) * Recommended wire sizing L1, L2, L3 400 kcmil (350 A) 1/0 AW (150 A) 2 AW (125 A) N 400 kcmil 1/0 AW 2 AW 3 AW 6 AW 6 AW EC 1/0 AW 1/0 AW 1/0 AW Provided by customer. Consult local and national codes for sizing requirements. Only on PDUs without a transformer. * In top cable entry, compression lugs are not used for the N and wires, a mechanical connection is used. ** EC not run if dual (bypass) input is present. 2 InfraStruXure PDU 80kW Installation

Torque specs and tools required overhead wiring Terminal Torque Tools L1, L2, L3 160 in-lb 11-ton crimping tool for lug onto the wire, 6-mm Allen wrench for compression lug onto the circuit breaker N (transformeless only) 125 in-lb 13-mm socket wrench 45 in-lb slotted screwdriver EC 50in-lb slotted screwdriver Torque specs and tools required underfloor wiring Terminal Torque Tools L1, L2, L3 500 in-lb 1/2-in Allen wrench N (transformeless only) 125 in-lb 13-mm socket wrench 45 in-lb slotted screwdriver EC 50in-lb slotted screwdriver Ensure Total Power Off 1. Set the UPS System Enable switch to the OFF position. 2. Set the Battery Enclosure and any XR Battery Enclosure DC Disconnect circuit breaker to the OFF position. 3. Set the Main Input switch (A), and, if applicable, the Q10 Bypass Input switch (B), and Cross Tie Output or MCCB Sub-feed circuit breaker (X) on the PDU to the OFF position. InfraStruXure PDU 80kW Installation 3

4. Open (turn OFF) the Q1, Q2, and Q3 circuit breakers on the PDU. 5. Set the upstream main input (and bypass input, if applicable) utility circuit breaker to the OFF or Locked Out position. A B Attach conduit to the PDU for the conductors 1. Remove one of the rectangular gland plates by loosening the captive screws, using a Phillips or standard screwdriver. For wiring under a raised floor: remove the plate in the floor of the PDU. 4 InfraStruXure PDU 80kW Installation

For overhead wiring: detach the user connection plate, route it through the opening in the gland plate, carefully set it aside (do not disturb the connected wires), and remove the gland plate in the roof of the PDU. 2. Cut an appropriately sized hole in the gland plate for each switch (or breaker) that you are connecting to. 3. Re-attach the gland plate. 4. Install a lock-nut and bushing to the conduit. 5. Thread the conduit through the hole in the gland plate. InfraStruXure PDU 80kW Installation 5

Install a utility/branch circuit breaker Warning: When you connect the InfraStruXure PDU to utility power, you must install a circuit breaker to protect the PDU from over-current. Determine the amperage of the circuit breaker that you need to install: Input Voltage Run input conductors Circuit Breaker Amperage 208 V 350 A 480 V 150 A 600 V 125 A For overhead wiring, route the conductors directly to the terminals on the Main Input switch, and if applicable, the Bypass Input switch and Cross Tie Output or MCCB Sub-feed circuit breaker. For wiring under the floor, route the conductors to the terminals in the bottom of the PDU that correspond to the Main Input switch, and if applicable, the Bypass Input switch and Cross Tie Output or MCCB Sub-feed circuit breaker. 6 InfraStruXure PDU 80kW Installation

Overhead wiring. See the following illustrations for the input conductors that you need to run for your PDU. The illustrations show PDUs with a Main Input (A), Bypass Input (B), and Cross Tie Output or MCCB Sub-feed circuit breaker (X). If your PDU does not have all three circuit breakers, make the connections shown for the breakers that are on your PDU. For overhead wiring, the PDU is equipped with lugs for the neutral and ground connections that you need to make. Crimp the provided lugs onto each ground and neutral wire. Refer to Torque specs and tools required overhead wiring on page 3 of this instruction sheet when making connections. Warning: Connect the input conductors to the terminals according to the labels on the terminals. Use copper conductors only. 208/480/600V input with a transformer A: 3-phase, 3-wire + ground + EC to building steel B: 208V, 3-phase, X: 208V, 3-phase, EC A L1 L2 L3 B L1 L2 L3 X L1 L2 L3 208V input without a transformer A: 208V, 3-phase, B: 208V, 3-phase, X: 208V, 3-phase, A L1 L2 L3 B L1 L2 L3 X L1 L2 L3 InfraStruXure PDU 80kW Installation 7

Under-floor wiring. See the illustrations below for the input conductors that you need to run for your PDU. The illustrations show PDUs with a Main Input (A), Bypass Input (B), and Cross Tie Output or MCCB Sub-feed circuit breaker (X). If your PDU does not have all three circuit breakers, make the connections shown for the breakers that your PDU has. Referenced Torque specs and tools required underfloor wiring on page 3 of this instruction sheet when making connections. Warning: Connect the input conductors to the terminals according to the labels on the terminals. Use copper conductors only. 208/480/600V input with a transformer A: 3-phase, 3-wire + ground + EC to building steel B: 208V, 3-phase, X: 208V, 3-phase, 208V input without a transformer A: 208V, 3-phase, B: 208V, 3-phase, X: 208V, 3-phase, L3 L1 L2 L1 L2 L3 L1 L2 EC A B X L3 L3 L1 L2 L1 L2 L3 L1 L2 A B X L3 8 InfraStruXure PDU 80kW Installation

Connect an Emergency Power Off (EPO) switch 1. Connect the switch to the EPO connection point terminals located on the bottom side of the PDU user connection plate. Read the label next to the terminal block to determine which terminals to connect to for the signal type you are using: Contact Closure Normally Open USER INTERFACE 2001 APC MADE IN USA External set of Normally Open Dry Contacts 1 2 3 4 Contact Inputs Contact Outputs ATS 0 ATS 1 ATS 2 ATS EN + EPO 24V EPO AC/DC Contact Contact Closure Normally Closed USER INTERFACE 2001 APC MADE IN USA External set of Normally Closed Dry Contacts 1 2 3 4 Contact Inputs Contact Outputs ATS 0 ATS 1 ATS 2 ATS EN + EPO 24V EPO AC/DC Contact 24VAC/VDC Normally Open USER INTERFACE 2001 APC MADE IN USA External set of Normally Open Dry Contacts 24V AC or DC Power Supply 1 2 3 4 Contact Inputs Contact Outputs ATS 0 ATS 1 ATS 2 ATS EN + EPO 24V EPO AC/DC Contact 2. Verify that the EPO DIP switches on the PDU monitoring unit are configured properly for the signal type you are using. The labels above the switches and the figure below show the correct settings for both the Normally Open (NO) and Normally Closed (NC) position. Normally Closed EPO TRIPPED ARMED TEST Location of switches on PDU monitoring unit Normally Open or 24V AC/DC Note: The default setting on the EPO interface on the PDU monitoring unit is for a Normally Open (NO) switch. For information on testing the Emergency Power Off (EPO) switch, see the 80kW InfraStruXure PDU Operation and Configuration manual (990-1468C). NO NC InfraStruXure PDU 80kW Installation 9

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ lobal support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers Direct InfraStruXure Customer Support Line APC headquarters U.S., Canada Latin America Europe, Middle East, Africa Western Europe (inc. Scandinavia) (1)(877)537-0607 (toll free) (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702000 (Ireland) +800 0272 0272 Japan (0) 35434-2021 Australia, New Zealand, South Pacific area (61) (2) 9955 9366 (Australia) Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2007 American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and InfrStruXure are trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-1469D *990-1469D* 07/2007