FLOW METERS. 90 left. 90 right. Sensor. Rotary display. Models. FA Series

Similar documents
The Multivariable Air Flow Meter

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

The Multivariable Air Flow Meter

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

MULTISTAGE MICRO EJECTORS

2-Color Display High-Precision Digital Pressure Switch

ACTUATORS GENERAL CATALOG

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Flow sensor for compressed air

ACTUATORS GENERAL CATALOG

Model Pressure range ON/OFF output Linear output

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

2-Color Display High-Precision Digital Pressure Switch

Flow sensor for compressed air

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

Series 10-ZSE40A(F)/10-ISE40A

A superb way to save energy when using compressed air or nitrogen. Air Flow Meter CP-PC-1474E

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Vacuum pump system type

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Stroke Sensors INDEX. Actuators CAUTION. RoHS directive compliant products

DPS280 / DVS280 Series

Sensor specifications Model no.

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Model Pressure range ON/OFF output Linear output

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Digital Flow Switch (Sensor Part) Operation Manual

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

PD3/PDV3-20A/25A/40A Series

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Differential Pressure Sensor

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Pressure sensor with built-in amplification and temperature compensation circuit

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Series AV2000/3000/4000/5000

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Motorized Two-Way Ball Valve with Screwed-End Connection

The mechanism that generates mist (moisture) Principles of water removal valve operation

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch

Gas Flow Monitor CMG152/252/402/502 USA Model User's Manual

Low Profile Insertion Vortex

SRT1000 Series THERMAL FLOWMETER

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

TOWA SEIDEN INDUSTRIAL CO., LTD.

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Related vacuum products

Standard Specifications. Model. Port (Bypass lubrication adapter)

Precision Clean Regulator

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Differential Pressure Transmitter

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

4 Note 1) Value for communications type. (PROFIBUS DP)

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Air Operated Valve Control Valve

MULTI SLIDERS CONTENTS

POWER REGULATOR LD -40PSU

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Seven Features of the Koganei Vacuum Valve

Digital Flow Switch (Integrated display type)

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

SPEED CONTROLLERS WITH QUICK FITTINGS

Vortex Plate. Model VP General Specification. Product Features

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Electro-Pneumatic Regulator Electronic Vacuum Regulator

SOLENOID VALVES, SERIES

Hot Tap Insertion Vortex

Transcription:

FLOW METERS FA Series Sensor A thermal mass sensor enables accurate measurement even in the case of gas temperature and pressure fluctuations. Sensor structure The FA Series measure flow rates using heat from the heater and a temperature sensor. In a no flow state, the air temperature distribution around the heater is uniform, so there is no difference in the temperature between the upstream and downstream temperature sensor positions. When flow is received in this state, the downstream temperature rises while the upstream temperature falls, so a temperature difference between the upstream and downstream sensor positions is generated. This temperature different is measured and a flow rate is calculated. Diaphragm Ambient temperature sensor Silicon chip FLOW Upstream temperature sensor Heater temperature sensor Measurement principles Rotary display The display of the can be rotated 9 to the left or 18 to the right, making it easy to read regardless of whether piping is horizontal or vertical. 9 left 18 right Standard position 9 right Temperature distribution Temperature distribution FLOW No flow state Flow received state Note: Do not try to rotate the display more than 9 to the left or 18 to the right. Models Practical measuring range of 5:1 (excluding some mounting directions) helps to provide an idea of air leaks. Model Port size Flow measurement range (±3% FS accuracy guaranteed range)r/min (normal) FAS-2 FAS-5 FAS-3 Rc1/4 Rc1/2 Rc1 4(1) Note 2 1(25) Note 5 6(15) Note 3 FAS-6 Rc1 1/2 12(3) Note 6 FAS-12 Rc2 24(6) Note 12 Note: Values in parentheses are flow measurement ranges for mounting directions 2 and 3. Refer to page 1675 for information about mounting directions. 1636

Features Separation measurement using an orifice for large-volume flow measurement at each piping port and small pressure load. A self-diagnostic function simplifies troubleshooting in the case of product trouble. In the case of the FAS-3, FAS-6, and FAS-12 models, replacement required in the case of malfunction can be achieve by replacing the bypass unit only, without detaching piping. However, the ±3%FS guaranteed accuracy of the replacement product becomes ±5%FS. Range extension function The FA Series displays up to double the maximum flow measurement range, and support analog output and switch output. However, the measurement accuracy of the additional part is approximately ±1%RD. * Remark: RD stands for "reading" (read value). With the FAS-2, error is ±3 ℓ/min (ANR) [±1.6 ft3/min] (normal) for an instantaneous flow display of 3 ℓ/min (ANR) [1.6 ft3/min] (normal) and error is ±4 ℓ/min (ANR) [±1.413 ft3/min] (normal) for an instantaneous flow display of 4 ℓ/min (ANR) [14.1 ft3/min] (normal). Reverse flow detection function FA Series s can display a reverse flow (flow in the opposite direction from unit's flow arrow) up to 3% of the maximum flow measurement range, and flow integration. However, reverse flow measurement accuracy is approximately ±6%FS, and analog output and switch output (except for some integrating functions) is not possible. Example of use A wide flow measurement range makes it possible to obtain an understanding of line stoppage time and the amount of leakage. The integrated reverse flow makes it possible to integrate reverse flows as well. Knowing the flow over time provides a means to reduce power consumption by optimization of compressor operations (load, unload, power off). Flow measurement between lines and divisions enables division-specific cost allocation. It also helps to avoid over use of air. The results of air consumption reduction is readily apparent from values that are produced. 1637

Safety Precautions (Flow Meters FA Series) The safety precautions below are specific to FA Series flow meters. For other safety precautions in addition to the information below, also be sure to read the safety precautions at the front of the general personal catalog. DANGER Do not attempt any adjustment (connecting or disconnecting wire connectors, piping work, etc.) to mechanisms attached to the product while the product is operating. Abnormal operation creates the risk of personal injury. WARNING Do not apply external magnetic field to the while it is operating. Unintended operations could damage equipment or cause injury. When wiring, take care to ensure that wiring polarity is correct. Incorrect polarity could result in damage to the. CAUTION Do not subject cables that have connectors to excessive loads by pulling on them, lifting the product by them, or by placing heavy objects on them. Doing so may cause current leakage or defective continuity leading to fire, electric shock, or abnormal operation. While handling the, do not subject them to excessive shock (49 m/s 2 [5 G] or greater) by hitting, dropping or bumping it. Even if the product appears undamaged, damage to internal components can cause abnormal operation. Avoid short circuiting loads. Turning on switch output while a load short-circuit condition exists can cause damage to the due to over current. Load short-circuit example: output lead of switch output connected to DC power supply. Handling Instructions and Precautions General precautions Mounting location Avoid installing the FA Series Flow Meter in the following types of locations. 1. Locations where the ambient temperature or product temperature is -1 [14 ] or lower, or exceeds 6 [14 ]. 2. Locations where the ambient humidity exceeds 9%RH. 3. Locations subjected to sudden temperature changes that can cause condensation. 4. Locations subjected to concentrations of corrosive and/or flammable gasses. 5. Locations subjected to high amounts of dust, salt, iron powder, or other conductive matter, moisture, oil mist, or organic solvents. 6. Locations where the product is directly subjected to vibration and/or impact. 7. Locations exposed to direct sunlight. 8. Locations where water, rain, or other moisture can get on the product. 9. Locations where oil or chemicals can get on the product. 1. Locations that are always wet or dusty, or subject to water or dust. 11. Locations where strong magnetism or strong electric fields are being generated. Operation outside the maximum flow range When the flow rate exceeds the maximum flow rate range of the FA Series Flow Meter, the alarm message " " will alternate on the display with the flow rate reading. Always use this within the specified maximum flow rate range. Piping Mounting and piping 1. The FA Series Flow Meter is a precision instrument. Take care when handling it. It can be damaged by dropping it or otherwise subjecting it to strong impact. 2. Whenever connecting piping to the FA Series Flow Meter, make sure that the direction of the arrow marked on it matches the flow direction of the fluid. 3. When connecting piping, do not apply force to the bypass unit section. 4. When connecting piping, secure the main flow channel and rotate the pipe to the suitable tightening torque range. Bypass unit Main flow path Model FAS-2 FAS-5 FAS-3 FAS-6 FAS-12 Port size Rc 1/4 1/2 1 1 1/2 2 Suitable tightening torque N m [in lbf] 12 to 14 [16.212 to 123.914] 31 to 33 [274.381 to 292.83] 36 to 38 [318.636 to 336.338] 59 to 61 [522.29 to 539.911] 74 to 76 [654.974 to 672.676] 1638 5. Take care to keep foreign matter from flowing into the FA Series Flow Meter. Any rust, water droplets, oil mist, dust, or other foreign matter inside piping that gets into the FA Series Flow Meter creates the risk of measurement error and damage to the. Before installation, be sure to thoroughly flush both the upstream and downstream piping (pipe cleaning) and check to make sure there is no foreign matter present.

Handling Instructions and Precautions 6. When connecting piping, apply an appropriate amount of sealant. Do not apply sealant to the first two threads of the end of the pipe. Over-application of sealant can cause it to get inside the piping, creating the risk of measurement error and damage to the FA Series Flow Meter. Liquid sealant Mounting direction 3: Horizontal piping mounting with display leftwards relative to the flow level meter IN size pipe. When using this installation attitude, set the low flow cut parameter value to 5. Failure to do so will cause the flow rate to be displayed (output) even when there is no fluid flowing. The normal flow side and back flow side integral functions activate, causing the flow rate values to be integrated. Direction of wrapping Sealing tape Up Direction of flow Leave 2 threads open. Leave 2 threads open. 7. If different-diameter piping, a regulator, filter, valve, or other piping equipment is installed upstream from the FA Series Flow Meter, be sure to provide a straight pipe section as recommended. See "Specification accuracy and straight pipe section" for more information. Failure to provide a straight pipe section can cause flow rate errors. 8. Connecting expansion pipe or a tube coupler without providing a straight pipe section can produce a negative flow rate reading due to back flow in bypass unit, even though there is normal flow as far as the product is concerned. 9. Installing the display section on horizontal piping so it is in a downward orientation may cause rust, water droplets, oil mist, dust, or other foreign matter to adhere to the sensor, creating the risk of measurement errors and damage to the FA Series Flow Meter. Do not use the display section in a downward orientation. Installing the display section on horizontal piping in a sideways orientation will cause errors due to the effect of the attitude. For details, see "Installation Attitudes" below. 1. Do not install in locations where the effects of pulsating flow or flow maldistribution are present, such as in the vicinity of the compressor delivery port, on bellows piping, etc. Also, do not install in a location where a regulator or check valve is performing hunting. Doing so creates the risk of measurement error. Mounting direction Viewed from IN side piping. Operating pressure range to 1 MPa [ to 145 psi] -.7 to MPa [-1 to psi] Down Mounting direction 4: With horizontal piping, display downwards. Do not use this mounting direction. Up Flow range 5 to 1% of FS flow 5 to 1% of FS flow Direction of flow Side drawing Instantaneous flow display change volume -.5% FS/.1 MPa [1.5 psi] 1 digit or lower -.5% FS/.1 MPa [1 psi] 1 digit or lower Example At a pressure of. 3 MPa when the is installed on horizontal piping with the display facing to the right when viewed from the flow meter IN side pipe, causes a change in the flow rate that is no more than 1. 5% FS 1 digit compared to the normal installation attitude. -.5[%FS/.1 MPa].3[MPa]=-1.5[%FS] Mounting direction 1: With horizontal piping, display upwards. (Standard direction) Up Direction of flow Down Side diagram Down Side diagram Mounting direction 2: Horizontal piping with the display on the right when viewed from the IN side pipe. When using this installation attitude, set the low flow cut parameter value to 5. Failure to do so will cause the flow rate to be displayed (output) even when there is no fluid flowing. The normal flow side and back flow side integral functions activate, causing the flow rate values to be integrated. Up Mounting direction 5: With vertical piping Up Direction of flow Direction of flow Viewed from IN side piping. Down Side diagram Direction of flow Down Operating pressure range to 1 MPa [ to 145 psi] -.7 to MPa [-1 to psi] Flow range 5 to 1% of FS flow Note 5 to 1% of FS flow Instantaneous flow display change volume.5% FS/.1 MPa [1.5 psi] 1 digit or lower.5% FS/.1 MPa [1 psi] 1 digit or lower Note: "FS flow" is the full scale flow. Example. At a pressure of.3 MPa when the is installed on horizontal piping with the display facing to the right, when viewed from the IN side pipe, causes a change in the flow rate that is no more than 1. 5% FS 1 digit compared to the normal installation attitude..5[% FS/.1 MPa].3[MPa]=1.5[%FS] 1639

Handling Instructions and Precautions Filter Whenever there is the risk of foreign matter (dust, sediment, oil mist, etc.) being mixed in with the measured fluid, be sure to install upstream from the FA Series Flow Meter a filter and mist filter that can remove foreign matter measuring 1 m or larger. Periodically inspect and replace filters, and perform other periodic maintenance as required. Specification accuracy and pipe section Install the FA Series Flow Meter so the arrow marked on its label is pointed in the same direction as the fluid flow direction. When connecting different diameter tubing, valves, filters, and other equipment, provides straight pipe in accordance with the information in the table below. A "straight pipe" is straight piping that is the same bore diameter as the. The following types of pipes are suitable as straight pipe: carbon steel pipes for ordinary piping (JIS G3452), carbon steel pipes for pressure service (JIS G3454), Schedule 4 or less, and stainless steel pipes (JIS G3459), Schedule 4. Note1 For equipment not included in the table below, provide 1 or larger straight piping when installing it upstream from the FA Series Flow Meter, and or larger straight piping when installing it downstream from the FA Series Flow Meter. The letter D represents the bore diameter. Note2 When measuring back flow in addition to normal flow, the same length as the upstream straight pipe is required downstream from the FA Series Flow Meter. Note 4: Contact Koganei for information about 1 1/2B and 2B size filters and mist filters. 5: Required direct piping when connecting a filter with the same diameter as the. 6: A reduction pipe connection example (within the product specification range ( 3%FS)) for the FAS-2 is shown below. FAS-2 3/8B 1/4B 3/8B When connecting one size larger piping (for example, 1/2B for the FAS-2), take the specified value*+ for direct piping before the and the specified value*+ for the direct piping after the. FAS-2 * Piping length when connecting piping one size larger than the specified value. 7: A reduction pipe connection example (within the product specification range ( 3%FS)) for the FAS-5is shown below. FAS-5 3/8B 1/2B 3/8B Piping, connection equipment Connection location Mist filter For FAS-2, FAS-5, FAS-3 Note3, 5 Mist filter For FAS-6, FAS-12 Note4, 5 1-size large port diameter piping (Reduction pipe connection) FAS-2 3/8B 1/4B FAS-5 3/4B 1/2B FAS-3 1 1/4B 1B FAS-6 2B 1 1/2B Note6 1-size larger port diameter piping (Reduction pipe connection) FAS-12 2 1/2B 2B Note6 1-size small port diameter piping (Expansion pipe connection) FAS-2 1/8B 1/4B FAS-5 3/8B 1/2B FAS-3 3/4B 1B FAS-6 1 1/4B 1 1/2B Note7 More than 1-size smaller small port diameter piping (Expansion pipe connection) FAS-12 1 1/2B 2B Note7 from from from from Straight pipe section with FA Series Specification ranges Within 3%FS 1D 2D Accuracy Within 5%FS Not required Not required Note 1: Note that accuracy deteriorates when piping carbon steel pipes for pressure service (JIS G3454) or stainless steel pipes (JIS G3459), larger than Schedule 4 is connected. A larger schedule results in a smaller pipe inside diameter which causes a pipe effect and deteriorated accuracy. 2: The approximate D (bore diameter) for FAS-2 (1/4B) is 8 mm [.315 in], for FAS-5 (1/2B) is 15 mm [.591 in], for FAS-3 (1B) is 25 mm [.984 in], for FAS-6 (1 1/2B) is 4 mm [1.575 in], and for FAS-12 (2B) is 5 mm [1.969 in]. 3: Always provide a filter upstream from the mist filter. Not required 1D 1 Not required 2 Not required Not required Not required Not required 1D 1D Not required Single elbow Note8 from Not required Not required 1D 1D Double elbow Note8 from Not required Not required Ball valve 2D 1D (Fully open elbow type) Note9 from 1D Regulator Note1 2D Not required FAS-2 from 1D Not required Regulator Note1 3D Not required FAS-5, FAS-3, FAS-6, FAS-12 from Not required Air filter 2 Not required 1 Do not connect piping that is thinner than the connection port without direct piping. Reverse flow by the bypass unit is possible even though the product is providing normal direction flow, and produce a negative reading on the flow display. Or an extremely low flow value may be displayed in place of the actual flow. Or when connecting one size smaller piping (for example, 1/4B for the FAS-5), take the specified value*+1d for direct piping before the and the specified value*+ for the direct piping after the. 2 FAS-5 1/4B 1/2B 1/2B 1/4B * Piping length when connecting piping one size smaller than the specified value. 8: Reference diagrams for a single elbow and double elbow are shown below. 1D 1D Single elbow Double elbow 9: Install valves for flow adjustment downstream from the. 1: Install when the distance from the is greater than the specified distance. It makes no difference whether piping from the regulator to the is constructed of tubing or an elbow bend. However, install the required direct piping when connecting with the flow meter with an elbow bend. Allow for distance even if a filter or mist filter is inserted. Regulator Distance from FAS-2: 2D or more Other machines: 3D or more Elbow Straight pipe minimum of 1D 164

For connection with a quick fitting Provide the straight pipe section noted in the table below when connecting the FA Series Flow Meter to a quick fitting. Connecting without a straight pipe section can produce a negative reading due to bypass unit back flow, even if flow in the main channel itself is normal direction flow. Also, the readout may show an extremely low flow rate instead of the actual flow rate. Quick fitting Tube Piping, connection equipment Quick fitting Tube size 8 [.315 in] (With FAS-2) Quick fitting Tube size 12 [.472 in] (With FAS-2) Direction of flow Quick fitting Tube size 12 [.472 in], 16 [.63 in] (With FAS-5) Quick fitting Tube size 12 [.472 in], 16 [.63 in] (With FAS-3) Direct piping Filling type Straight type Elbow type Straight type Elbow type Straight type Elbow type Straight type Elbow type Connection location Straight pipe section with FA Series Specification ranges Note Within 3%FS Accuracy Note Within 5%FS 1 from Not required Not required 2D 1D from Not required from Not required Not required 1D from 1D from Not required Not required 1 1D from 1D 8D from 1 13D from 1D 1D Note: Characteristics for connection when tubing from fitting is virtually straight for approximately 3 mm [11.8 in]. Connections 1. Use a power supply that is within the specification range. 2. Wire a cable with connector separately from power lines and high voltage lines (use a separate conduit). Noise from these lines may cause the equipment to operate erratically. 3. When connecting a cable with connector, align the core wire and push it in as far as it will go. Next, tighten the connector nut by hand. When tightening the nut, be sure to keep it within the prescribed torque (.4 to.6 N m [3.54 to 5.311 in lbf] range). Failure to do so creates the risk of damage to the FA Series Flow Meter and inability to maintain the IP65 protective structure, and loosening of the nut due to vibration. 4. Do not pull on the cable with strong force and do not lift the FA Series Flow Meter by the cable (pull out strength: 4 N [8.992 lbf] or less; bend strength; 2 N [4.496 lbf] or less). Also, do not subject the cable to repeated bending or pulling force. 5. Do not rotate the center part of the connector (see figure below) while the connector is inserted fully into the FA Series Flow Meter. Doing so will cause the FA Series Flow Meter connector to rotate, which can cause internal wiring to twist and become damaged. Cable with connector Connector root Connector nut 6. Always turn off the power supply before doing any wiring. 7. Keep load resistance connected to the instantaneous flow rate output below 3. 8. Keep cable and connector ends away from moisture when doing wiring. 9. Double-check to make sure that wiring is correct before turning on power. Wiring error creates the risk of damage and erratic operation. Pin number 1 2 3 4 Signal name V+ I+ COM EV Description 24 VDC Instantaneous flow output (4 to 2 ma) COM Switch output Key Relationship between connector cable colors and pin numbers Pin number 1 2 3 4 Signal name V+ I+ COM EV Wire colors Brown White Blue Black Example connection 1 V (brown) 2 3 I (white) + Instantaneous flow output Allowable load 4 to 2mA Load resistance COM (blue) 3 or less 22.8 to 25.2 VDC Inner circuit 4 EV (black) Load 3 VDC, 5 ma or less + 3 VDC or less Example external connection 1641

Specifications Item Model Media Port size Flow measurement range Note6 /min (normal) [ft 3 /min] Minimum sensitivity flow /min (normal) [ft 3 /min] Maximum flow range /min (normal) [ft 3 /min] Display resolution Note5 Instantaneous flow /min (normal) [ft 3 /min] Integrated flow /min(normal) [ft 3 /min] m Maximum display range 3 /h (normal) m 3 /min(normal) kg/h Instantaneous flow display accuracy Instantaneous flow display repeatability Temperature characteristics Operating pressure to 1 MPa [ to 145 psi] Pressure characteristics Operating pressure -.7 to MPa [-1 to psi] Operating pressure Instantaneous flow display to 1 MPa [ to 145 psi] change volume by mounting Operating pressure direction 2 Note 8 -.7 to MPa [-1 to psi] Operating pressure Instantaneous flow display to 1 MPa [ to 145 psi] change volume by mounting Operating pressure direction 3 Note 8 -.7 to MPa [-1 to psi] Operating pressure range Operating temperature range Operating humidity range Storage temperature range Storage humidity range Proof pressure Amount of external leakage Rated voltage Power supply voltage range Consumption current Calculation cycle Instantaneous flow output Note1 Response time Switch output Note11 FAS-2 4 2 (1 2) [.141 7.1 (.353 7.1)] 2 [.71] 6 4 [ 2.119 14.1] 1 [.35] 1 [.353] 6 4 [-2.119 14.1] 3.6 24..6.4 4.7 31. FAS-5 FAS-3 FAS-6 FAS-12 1 5 (25 5) [.353 17.7 (.883 17.7)] 5 [.177] 15 1 [ 5.3 35] 1 [.35] 1 [.353] 15 1 [ 5.3 35] 9. 6..15 1. 11.6 77.6 Air, nitrogen However, dry air that does not include corrosive elements (salt, sulfur, acid, etc.) ( Clean gas that does not include dust and/or oil mist ) Rc1/4 Rc1/2 Rc1 Rc1 1/2 Rc2 6 3 (15 3) [2.119 16 (5.3 16)] 3 [1.6] 9 6 [ 31.8 212] 5 [.177] 1 [.353] -9 6 [-31.8 212] 54. 36.9 6. 7 465.5 -.7 1. MPa [-1 145 psi] (gauge pressure) -1 +6 C [14 14 F] (non-freezing) 9% RH (Non-condensation) -2 +7 C [-4 158 F] (non-freezing) 9% RH (Non-condensation) 1.5 MPa [218 psi] (gauge pressure) 1 ml/h (normal) (When internal pressure is 1.5 MPa [218 psi]) 24 VDC 22.8 25.2 VDC 12mA Max. 5 5ms (when shipped) 12 6 (3 6) [4.2 212 (1.6 212)] 6 [2.119] 18 12 [ 64 424] 1 [.353] 1 [3.5] 18 12 [ 64 424] 18. 72. 1.8 12. 14. 931. 24 12 (6 12) [8.5 424 (21.2 42.4)] 12 [4.2] 36 24 [ 127 848] 1 [.353] 1 [3.5] 36 24 [ 127 848] 22. 144. 3.6 24. 279. 1862. 3% FS 1digit (2 1% of FS flow, 5 1% in the case of mounting directions 2 and 3) Note9 6% FS (-3 % of FS flow) 1% RD (1 2% of FS flow) Note7 1.% FS 1digit (2 1% of FS flow) 2% FS (-3 % of FS flow) 1% RD (1 2% of FS flow) Note7.15% FS/ C 1digit or lower -.25% FS/.1 MPa [1.5 psi] 1digit or lower (2 4% of FS flow) -.55% FS/.1 MPa [1.5 psi] 1digit or lower (4 1% of FS flow).25% FS/.1 MPa [1 psi] 1digit or lower (2 4% of FS flow).55% FS/.1 MPa [1 psi] 1digit or lower (4 1% of FS flow).5% FS/.1 MPa [1.5 psi] 1digit or lower (5 1% of FS flow).5% FS/.1 MPa [1 psi] 1digit or lower (5 1% of FS flow) -.5% FS/.1 MPa [1.5 psi] 1digit or lower (5 1% of FS flow) -.5% FS/.1 MPa [1 psi] 1digit or lower (5 1% of FS flow) Current output, 1 point: 4-2mA (Output range: 3.2 2.8 ma) Alarm time fixed output (up): 21.6.4 ma (Default, can be changed by setting) Alarm time fixed output (down):..4ma fixed Allowable load resistance: 3 or less Maximum output current: 24 ma Within 1.5s (Time reach 95% of final value upon step input of 1%FS; Calculation cycle: 5 ms) Open collector output, 1 point: 3 VDC, 5 ma or less One of the functions below can be selected. Instantaneous flow upper limit, lower limit, range Integrated flow count up, count down Alarm generation Integration pulse output (3-level selectable pulse weight) 1642

Specifications Item Model Data recording Dielectric strength Insulation resistance Cable Mounting direction Protective structure Main flow path Gas contact part material Bypass unit Gasket Bypass unit case material Load mass kg [lb] FAS-2 FAS-5 FAS-3 FAS-6 FAS-12 Semiconductor non-volatile memory EEPROM Recorded data: Function settings, parameters, integrated values, etc. Leakage current of 1 ma or less 5 VAC applied for one second between the connector pin and main flow path or mounting bolt 5 M or more 5 VDC megger applied for one second between the connector pin and main flow path or mounting bolt Option (with connector, oil resistant, flame retardant cable; UL2464EN standard) Refer to "Mounting direction" on page 1675. IP65 (JISC92 and IEC529); splash resistant and dust resistant, assuming indoor installation) Aluminum alloy (anodized) SUS34, PBT, H-NBR (hydrogenated nitrile rubber) H-NBR (hydrogenated nitrile rubber) Denatured PPO.4 [.882].4 [.882].5 [1.12].7 [1.543] 1.1 [2.425] Note 1: (normal) is a value converted to a C [32 F], 11.325 kpa [29.9 inhg] (abs) flow. 2: "FS flow" is the maximum flow of the flow measurement range. 3: "RD" stands for "reading" (read value). 4: A minus ( ) flow rate value indicates a back flow rate (flow in the direction opposite that indicated by the arrow). 5: Regardless of the unit of display and the decimal point position, this indicates resolution from the lowest display digit. 6: A flow rate inside of parentheses ( ) is for installation attitudes 2 and 3. 7: This accuracy is a value representing instantaneous flow rate display accuracy along with instantaneous display repeatability. 8: See the installation attitudes on page 1675. 9: Replacing the bypass unit with a new unit causes instantaneous flow rate display accuracy to become 5 FS 1 digit. (FAS-3, FAS-6, FAS-12) 1: The back flow side cannot output. 11: Back flow side settings cannot be configured. Order Codes FAS - - - - Flow Meters FA series Flow rate ranges 2: to 2 /min(normal) [ to 7.1 ft 3 /min] 5: to 5 /min(normal) [ to 17.7 ft 3 /min] 3: to 3 /min(normal) [ to 16 ft 3 /min] 6: to 6 /min(normal) [ to 212 ft 3 /min] 12: to 12 /min(normal) [ to 424 ft 3 /min] Length of cable with connector Blank : no cable Mounting bracket Note 2L : 2 mm [79 in] Blank : None 5L : 5 mm [197 in] B : With mounting bracket Note: Mounting brackets are for FAS-2, -5, and -3 only. Inspection report Blank : None T : Inspection report appended Additional Parts Bypass unit (For FAS-3, -6, -12 only.) FAB Mounting bracket (For FAS-2, -5, -3 only.) B-FAS Cable with connector (Azbil Corporation) PA5-4ISX2SK (Cable length: 2 mm [79 in]) PA5-4ISX5SK (Cable length: 5 mm [197 in]) 1643

Pressure Loss FAS-2 Pressure loss kpa 6 4 2 5 1 15 2 Flow volume R/min (normal) Primary side pressure.1mpa.3mpa.5mpa.7mpa Pressure loss kpa 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi 2 15 1 5 1 2 3 4 Flow volume R/min (normal) Primary side pressure.1mpa.3mpa.5mpa.7mpa 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi FAS-5 15 Primary side pressure.1mpa 6 Primary side pressure.1mpa Pressure loss kpa 1 5.3MPa.5MPa.7MPa Pressure loss kpa 4 2.3MPa.5MPa.7MPa 1 2 3 4 5 Flow volume R/min (normal) 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi 2 4 6 8 1 Flow volume R/min (normal) 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi FAS-3 Pressure loss kpa 2 15 1 5 Primary side pressure.1mpa.3mpa.5mpa.7mpa Pressure loss kpa 8 6 4 2 Primary side pressure.1mpa.3mpa.5mpa.7mpa 5 1 15 2 25 3 Flow volume R/min (normal) 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi 1 2 3 4 5 6 Flow volume R/min (normal) 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi FAS-6 2 Pressure loss kpa 15 1 5 1 2 3 4 5 6 Flow volume R/min (normal) Primary side pressure.1mpa.3mpa.5mpa.7mpa Pressure loss kpa 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi 8 6 4 2 2 4 6 8 1 12 Flow volume R/min (normal) Primary side pressure.1mpa.3mpa.5mpa.7mpa 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi FAS-12 1644 Pressure loss kpa 25 2 15 1 5 Primary side pressure.1mpa.3mpa.5mpa.7mpa 1kPa =.2954 inhg 1 /min (ANR) = 2 4 6 8 1 12.3532 ft 3 /min (SCFM) Flow volume R/min (normal) 1 MPa = 145 psi Pressure loss kpa 1 8 6 4 2 4 8 12 16 2 24 Flow volume R/min (normal) Primary side pressure.1mpa.3mpa.5mpa.7mpa 1kPa =.2954 inhg 1 /min (ANR) =.3532 ft 3 /min (SCFM) 1 MPa = 145 psi

Dimensions mm [in] FAS-2 FAS-5 9 [3.543] 78 [3.71] Cable with connector (option) -2L: Cable length 2 mm [79 in] ( -5L: Cable length 5 mm [197 in] ) 75 [2.953] 63 [2.48] 5.5 [.217] 4.5 [.177] Mounting bracket (-B) M12 Connector ( 6 [.236]) 73.8 [2.96] 65.8 [2.591] IN OUT (46.5 [1.831]) 15 [.591] 34 [1.339] 1.5 [.59] 2-M4.7, depth 7 [.276] (Mounting screw hole) 75 [2.953] 48 [1.89] 24 [.945] 13.5 [.531] 23.5 [.925] 47 [1.85] FAS-2 : 2-Rc1/4 FAS-5 : 2-Rc1/2 27 [1.63] FAS-3 9 [3.543] 78 [3.71] Cable with connector (option) -2L: Cable length 2 mm [79 in] ( -5L: Cable length 5 mm [197 in] ) 5.5 [.217] (6.5 [2.382]) 23.5 [.925] 48 [1.89] 9 [3.543] 48 [1.89] 24 [.945] 13.5 [.531] 2-Rc1 27 [1.63] 75 [2.953] 63 [2.48] ( 6 [.236]) 4.5 [.177] Mounting bracket (-B) M12 Connector 87.8 [3.457] 79.8 [3.142] IN OUT 1.5 [.59] 2-M4.7, depth 7 [.276] (Mounting screw hole) 23.5 [.925] 47 [1.85] 1645

Dimensions mm [in] FAS-6 Cable with connector (option) -2L: Cable length 2 mm [79 in] ( -5L: Cable length 5 mm [197 in] ) M12 Connector ( 6 [.236]) 61 [2.42] 3.5 [1.21] 17 [.669] 6 [2.362] 2-Rc1 1/2 34 [1.339] 93.8 [3.693] IN OUT (74.5 [2.933]) 3 [1.181] 62 [2.441] 2-M5.8, depth 7 [.276] (Mounting screw hole) 1 [3.9] 3 [1.181] FAS-12 Cable with connector (option) -2L: Cable length 2 mm [79 in] ( -5L: Cable length 5 mm [197 in] ) 16.8 [4.2] (87.5 [3.445]) 11 [4.3] 61 [2.42] 3.5 [1.21] 2-Rc2 34 [1.339] ( 6 [.236]) M12 Connector IN OUT 37.5 [1.476] 75 [2.953] 37.5 [1.476] 75 [2.953] 2-M5.8, depth 7 [.276] (Mounting screw hole) 17 [.669] 1646

Additional Parts Dimensions mm [in] Bypass unit FAB 72 [2.835] 61 [2.42] (1 [.39]) 4-5.5 [.217] (6 [.236]) 34 [1.339] 45 [1.772] 51 [2.8] (11.5 [.453]) 27 [1.63] 5 [1.969] 63 [2.48] 75 [2.953] 3 [.118] (12.5 [.492]) 31.8 [1.252] Mounting bracket B-FAS 4-4.5 [.177] 1.5 [.59] 8 [.315] 48 [1.89] 78 [3.71] 9 [3.543] 4.5 [.177] 5.5 [.217] Cross head pan screw M4.7 Length6 [.236] Two attached Cable with connector (Azbil Corporation) PA5-4ISX2SK (Cable length: 2 mm [79 in]) PA5-4ISX5SK (Cable length: 5 mm [197 in]) PA5-4ISX2SK : 2 [79] ( PA5-4ISX5SK : 5 [197]) ( 14 [.551]) (4 [1.575]) (4 [1.575]) ( 6 [.236]) 1647

Setting Guidelines Nomenclature and functions q Mounting bolts Integration functions The function setting can be configured for integrated count up or integrated count down. y Bypass unit t r Display w e Connector When the integrated count up reaches 999999999, it reverts to and continues from there. Integrated count down continues from the specified starting value until it reaches. Count down stops when the integrated value becomes. The integrated count up values are recorded in non-volatile memory every 1 counts. This means that, depending on when power is cut, the exact current integrated count up value may not be stored in memory. Also, note that the integrated count down value is not recorded. To reset the integrated value to, check to make sure that the count screen upper order digits or lower digits are displayed, and then hold down both the and for at least five seconds. In the case of a integrated countdown, the above operation resets the integrated value to the integration event set value. An integrated value reset records the current integrated value to non-volatile memory. IN Main flow path OUT Integrated process and operations during back flow The integrated process when back flow occurs is performed in accordance with the selected integrated option as shown in the table below. 1 Flow rate display : 5-digit, 7-segment LED that normally shows the instantaneous flow rate and integrated flow rate. For integrated flow rate, the displayed value is divided between the four highest digits and five lowest digits. In setting mode, the display shows setting items and values. When an alarm occurs, it shows an alarm code. Integrated flow rate display of highest digits Integrated flow rate display of lowest digits C12 Setting : Normal flow and back flow integrated separately Process details Normal flow and back flow are integrated separately. Instantaneous flow rate Normal flow rate integration Integration counter + + Normal flow rate integration Back flow counter Back flow rate integration Integrated flow rate 9 9 9 9 9 9 9 9 9 2 LED lamps : L/min Lights during instantaneous flow rate display. L/min Lights during integrated flow rate display. EV Remains lit while switch output is on. AL Lights when an alarm occurs. Key switches : 6 Used to switch the display screen, enter setting mode, etc. 5 4 Used to configure function settings and parameter settings, to switch between the instantaneous flow rate peak value, lower value, and information display, and to reset the integrated value. 3 Used to check configuring function and parameter setting contents, and to go to the information display. 1: Integration with back flow compensation When an instantaneous back flow is generated, the normal flow integrated counter counts up after the back flow integration amount reaches zero. Instantaneous flow rate Normal flow Normal flow rate integration Integration counter Back flow counter Back flow Normal flow Main flow path : Connects to piping. There is an IN side and an OUT side. Bypass unit : FAS-3, FAS-6, and FAS-12 suppor t replacement with new bypass unit. Display: Connector: The display on top of the bypass unit can be rotated so it is parallel with the flow path. From the basic position shown in the illustration above, the display can be tilted 18 right or 9 left, a range of 27. Used for power input and signal connection. Mounting bolts : Secures the bypass unit to the main channel. 1648 Count up is suspended during back flow Back flow rate integration The back flow counter integration remains during this period, so suspension continues The stock of the back flow counter reaches, so the integration counter starts count up again after this point The integration counter stops counting up during back flow and the back flow is stocked to the back flow counter. After that, if the flow becomes normal, the portion stocked on the back flow counter is consumed and then the integration counter starts count up again. Note: In either case, the back flow integrated volume can be viewed on the information display.

Switch output Switches One of the switches shown in the table below can be selected. Except for integrated pulse output, you can also select inverted output. Switch Instantaneous flow rate upper limit switch Instantaneous flow rate lower limit switch Instantaneous flow rate range switch Integrated flow rate count up switch Integrated flow rate countdown switch Integrated pulse output Alarm output Model-specific pulse weight Model Minimum unit Operation Outputs when the value set with the instantaneous flow rate switch 1 parameter is exceeded. Outputs when the value set with the instantaneous flow rate switch 1 parameter is subceeded. Outputs when instantaneous flow rate is within the range set by instantaneous flow rate switch 1 and instantaneous flow rate switch 2. Outputs when the value set with the integrated switch setting parameter is exceeded. Outputs when a value of zero results after the value set with the integrated switch setting parameter is decremented. Performs pulse output of the integrated flow rate with the pulse weight set by switch output of the function setting. Function settings can be used to select a pulse width of 5 ms, 25 ms, or 5 ms. For information about the pulse weights see the table below. Outputs when an alarm is generated. Setting [R/pulse] Minimum unit x 1 Setting [m 3 /pulse, kg/pulse] Minimum Minimum Minimum Minimum unit x 1 unit unit x 1 unit x 1 FAS-2 1 1 1.1.1 1 FAS-5 1 1 1.1.1 1 FAS-3 1 1 1.1.1 1 FAS-6 1 1 1.1 1. 1. FAS-12 1 1 1.1 1. 1. Switch hysteresis When the instantaneous flow rate switch is selected, sets the hysteresis (operation interval). Switch on delay When the instantaneous flow rate switch is selected, sets the delay until switch operation. Switch wait When the instantaneous flow rate lower limit switch of the instantaneous flow rate switch is selected, specifies switch operation wait unit a lower limit setting value is exceeded once before power is turned on. Displays Instantaneous flow rate screen and integrated flow rate screen The seven segments of the display can be switched between instantaneous flow rate and integrated flow rate. Up to five digits are used for instantaneous flow rate display. A total of nine digits are shown for integrated flow rate value, with the displayed value is divided between the four highest digits five lowest digits. When the four highest digits are displayed, the leftmost 7-segment LED shows for countup or for countdown. If there is no countdown/up indication, it means that the lowest digits are displayed. Instantaneous flow rate peak value and lower value These values show the instantaneous flow rate peak value and low value during the measurement period. The measurement period can be reset (started) using a operation. Information display The information display function can be used to view the model ID, firmware version, cumulative integrated values, and integrated value before integration reset. Flow rate display unit The display unit for instantaneous flow rate and integrated flow rate can be changed as required. Flow rate display example Display unit setting C2 : C2 : 1 C2 : 2 C2 : 3 Unit /min (ANR) [ft 3 /min (SCFM)], R m 3 /h, m 3 [ft 3 ] m 3 /min, m 3 [ft 3 ] kg/h, kg [lb] Instantaneous flow rate 2 [7.1] 12. [423.72].2 [7.62] 15.5 [34.172] Integrated flow rate 1 [3532] 1. [3531] 1. [3531] 1. [22462] Conversion from R/min to each unit are shown below. 3 /h=r/min 6 1 kg/h=r/min 6 1 1. 293 Density at [32 ], 11.325 kpa [29.9 inhg] (abs) is assumed to be 1. 293. Note: After changing the unit of flow rate display, select the applicable sticker from among those provided and affix it to the. Analog output The instantaneous flow rate is output as an analog current (4 to 2 ma). Parameter settings can be used to change the flow rate value (display value) at 2 ma output. Setting resolution can be set in display value 1-digit intervals. Initial default settings are 4 ma at flow rate, and 2 ma at 1% FS flow rate. Operating pressure selection Selecting a value that is in the vicinity of operating pressure will perform output compensation of the selected pressure and reduce the effects of pressure characteristics. Reference temperature selection The flow rate display reference temperature can be set in 1 [34 ] steps within the range of to 35 [32 to 95 ]. (Factory default temperature is. ) Low flow cut Low flow cut can be set in 1% steps within the range of 1 to 5% of FS flow rate (factory default: 1%). At a setting of 1%, for example, is always displayed as the flow rate when the FS flow rate is within the range of 1 to 1%. The low flow cut setting is applied to instantaneous flow rate and integrated display values, and to the analog output value. Self-diagnostic function The self-diagnostic function automatically causes the FA Series Flow Meter to display an alarm whenever there is an abnormality in the output signal of the sensor that measures the flow rate or a memory abnormality. Back flow measurement Enables measurement of back flow up to 3% of the FS flow rate. Note: For information about accuracy, see the specifications on page 1678 and 1679. Flow rate range expansion function Enables measurement up to 2% of the FS flow rate. Note: For information about accuracy, see the specifications on page 1678 and 1679. 1649

Setting Guidelines Settings State transition Key 2 seconds Maintenance mode Function settings qwhile the basic screen is displayed, hold down the for about two seconds. The three digits on the left will show the function number, while the two digits on the right will show the current setting of the function. Power on Instantaneous flow rate display Key Integrated flow low-order digit display Key Integrated flow high-order digit display Key Home display Note1 Key 2 seconds Key 2 seconds Key 2 seconds Instantaneous flow rate peak value Key display Key 2 seconds Instantaneous flow rate lower value Key display Key 2 seconds Key Function setting mode Parameter setting mode Information display + 2 seconds Key 2 seconds Note 1: The basic screen shows instantaneous flow rate, integrated flow rate lowest digits, or integrated flow rate highest digits, in accordance with the function number setting. When an alarm is generated, the alarm code and basic screen alternate at an interval of two seconds. Each press of the cycles through the screens in the following sequence: Instantaneous flow rate Integrated flow rate lowest digits Integrated flow rate highest digits Alarm code Instantaneous flow rate. 2: Integrated value reset While the integrated flow rate highest digits or lowest digits are displayed, hold down the and s at the same time for about five seconds. Normally this will reset the integrated value to " ". However, when the switch output select is configured for integration countdown ( or ), the integration switch setting values ( and ) will be set. Example of display Function number Current setting value wuse the and s to scroll through the function numbers and display the one you want to change. Next, press the. This will cause the function number to disappear, leaving the two-digit setting value on the display. euse the and s to scroll through the settings and display the one you want. Next, press the. This will apply the setting and display the corresponding function number and setting value. Instead of pressing the in the above procedure, pressing the will return to the function number/ setting value display without changing the setting. rto configure other settings, repeat steps w and e as many time as required. To exit function selection, hold down the for about two seconds to change to the parameter setting screen. Next, hold down the again for about two seconds to return to the basic screen. Basic screen Function selection Setting number selection 2 seconds Function settings mode (Return without confirming the setting number) (Confirm the setting number and return) CAUTION Do not operate s by pressing with a mechanical pencil, a screw driver, or any other pointed object. Doing so can lead to malfunction. 2 seconds Setting parameters mode 2 seconds Basic screen 165

Function setting list Function number Description Setting lock Setting number and description : No lock 1: Key lock Default Remarks You can also use this setting to cancel lock. Performing a change operation while lock is engaged will cause " " to be displayed. Setting parameters qwhile the basic screen is displayed, hold down the for about two seconds to enter the function select mode. Next, hold down the again for about two seconds to enter parameter setting mode. Example of display when setting parameter items Example of display during setting Display unit setting Instantaneous flow rate, integrated flow rate Note :R/min, R 1: m 3 /h, m 3 2: m 3 /min, m 3 3: kg/h, kg Caution: After changing the unit, existing integrated values continue to be integrated in the previous unit. They are not converted automatically. After changing the unit, reset integration before using it again. The peak value and lower value are reset when the unit is changed. wuse the and s to scroll through the setting items and display the one you want. Next, press the. This will display a value with the rightmost digit flashing. epress the to move the flashing to the left. flashing flashing Switch output Basic screen Switch wait : Not used 1: Instantaneous flow rate upper limit 2: Instantaneous flow rate lower limit 3: Instantaneous flow rate range 4: Instantaneous flow rate upper limit (inverted) 5: Instantaneous flow rate lower limit (inverted) 6: Instantaneous flow rate range (inverted) 7: Integrated count up 8: Integrated count up (inverted) 9: Integrated countdown 1: Integrated count down (inverted) 11: Integrated pulse (minimum unit) 12: Integrated pulse (Minimum unit x 1) 13: Integrated pulse (Minimum unit x 1) 14: Alarm generation switch 15: Alarm generation switch (inverted) : Instantaneous flow rate screen 1: Integrated lowest digit screen 2: Integrated highest digit screen : Not used 1: Use Inversion causes output ON and OFF to be inverted. Determines the content of the flow rate display when power is turned on. The function setting mode is entered from the basic screen. Gas type : Air, nitrogen (fixed) Cannot be changed. Operating pressure Reference value conversion Integration options Integrated pulse width Fixed output during alarm :. 3 MPa standard 1:. 1 MPa standard 2:. 5 MPa standard 3:. 7 MPa standard to 35 (1 steps) : Integration with only normal flow rate 1: Integration with back flow compensation : 5 ms 1: 25 ms 2: 5 ms : Not used 1: Up 2: Down (fixed) When the installation attitude is "Installation attitude 2" or "Installation attitude 3", error due to installation attitude can be reduced by maintenance mode pressure compensation adjustment value and operating pressure. For details, see " Maintenance Mode" on page 169. Changing setting resets peak value and lower value. Outputs a fixed value from instantaneous flow rate output when a sensor abnormality or memory abnormality occurs. Flow rate indication is zero when an alarm occurs. Note: After changing the display unit setting, select the provided sticker that corresponds to the new unit and affix it to the. ruse the and s to change the value of the currently flashing digit. Use the and s to change each of the digits until the value is the one you want. tafter the value is the one you want, press the This will display the setting item and its set value.. yto configure other settings, repeat steps w through t as many time as required. uto exit the setting procedure, while a setting item is displayed hold down the for about two seconds to return to the basic screen. Basic screen Function settings mode Display item selection Settings Note 2 seconds 2 seconds 2 seconds Basic screen Setting parameters mode Note: As the setting values increase, 9 becomes and the value to the left increases by 1. In the same way, as the value decreases becomes 9 and the value to the left decreases by 1. 1651

Setting Guidelines Parameter setting list Display item Item content Setting range Default Remarks Analog output 2 ma flow rate specification Note 1 Analog output 4mA flow rate specification Note 1 Instantaneous flow rate switch Output 1 Note 2 Switch output hysteresis 1 Note 2 Switch output on delay 1 Note 3 Instantaneous flow rate switch output 2 Note 2 Switch output hysteresis 2 Note 2 Flow rate value equivalent to to 4% FS can be set. Note 5 Depends on model number. Flow rate value equivalent to to 4% FS can be set. Note 5 Flow rate value equivalent to to 4% FS can be set. Note 5 to 1% FS flow rate 1 to 6 s Flow rate value equivalent to to 4% FS can be set. Note 5 to 1% FS flow 1 rate Switch output on to 6 s delay 2 Note 3 Output compensation factor.1 2. 1. Initial default depends on model. FAS-2 2 FAS-5 5 FAS-3 3 FAS-6 6 FAS-12 12 Setting ranges are values with decimal points removed. Decimal points will be added with model settings. Expected output cannot be obtained when the setting values is less than 1% of FS. Setting zero outputs fixed output during an alarm. Reconfigure this setting after changing the display unit setting with function selection. Settings are values with decimal points removed. Decimal points will be added with model settings. This setting can be configured when function selection is set to through. Settings are values with decimal points removed. Decimal points will be added with model settings. Reconfigure this setting after changing the display unit setting with function selection. This setting can be configured when function selection is set to or. Settings are values with decimal points removed. Decimal points will be added with model settings. Reconfigure this setting after changing the display unit setting with function selection. Can be set in. 1 steps. Display value is reflected in output. Changing setting resets peak value and lower value. Low flow cut 1 5 1 Applied to both normal and back flow. Maximum display value Integration switch setting value lowest digits Integration switch setting value highest digits 1 2 2 9999 9999 Cost rate Note 4 1. 1. 1. Changes display range maximum value from standard 2% of FS. When flow rate exceeds setting value, set maximum display value alternates with error display (flow rate over). Can be configured when function selection is set to through. Specifies the cost rate when cost is displayed on information display. Note 1: Analog output scaling Output for an instantaneous flow rate value is calculated using the formula below. 1652 ([Indicated Flow Rate] [4 ma Setting Value]) 16 4 [ma] ([2 ma Setting Value] [4 ma Setting Value]) 4 A setting value : Instantaneous flow rate when 4 ma is output 2 A setting value : Instantaneous flow rate when 2 ma is output Minus flow output limit is 3. 2 ma, plus side output upper limit is 2. 8 ma. When [4 ma Setting Value ] [2 ma Setting Value ], a fixed output value will be output during an alarm. When [2 ma Setting Value] [4 ma Setting Value] 1% of FS flow rate, resolution is insufficient so desired output may not be possible. Note 2: Instantaneous flow rate switch operation Operation depends on the setting of function selection. (1) When function selection is set to or (instantaneous flow rate upper limit switch) After exceeding the instantaneous flow rate upper limit value and the switch turning on, the settings for conditions to turn the switch off are set to hysteresis. [Switch OFF Conditions] = [Instantaneous Flow Rate Upper Limit Value] [Hysteresis] Hysteresis is specified as a percentage (%) of the FS flow rate. ON (OFF) OFF (ON) Flow rate low ( ) indicate inverted output Hysteresis Setting value Flow rate high Note: If the hysteresis threshold value is set below, the threshold value becomes and if the flow rate is minus, it turns off. (2) When function selection is set to or (instantaneous flow rate lower limit switch) After falling below the instantaneous flow rate lower limit value and the switch turns on, the settings for conditions to turn the switch off are set to hysteresis. [Switch OFF Conditions] = [Instantaneous Flow Rate Lower Limit Value] + [Hysteresis] Hysteresis is specified as a percentage (%) of the FS flow rate. ON (OFF) OFF (ON) Flow rate low ( ) indicate inverted output Setting value Hysteresis Flow rate high (3) When function selection is or (instantaneous flow rate range switch) When, the setting value is the upper limit and the setting value is the lower limit. When, the setting value is the lower limit and the setting value is the upper limit. Operation does not work when =. Hysteresis operation can be taken outside of the lower and upper limit setting values as shown below. Hysteresis is specified as a percentage (%) of the FS flow rate. Different settings can be specified for the upper limit value and lower limit value. When setting value setting value ON (OFF) OFF (ON) Flow rate low ( ) indicate inverted output ON (OFF) OFF (ON) Flow rate low ( ) indicate inverted output Hysteresis Hysteresis Setting value Setting value Setting value Flow rate high Hysteresis When setting value setting value Setting value Flow rate high Hysteresis Note: If the hysteresis threshold value is set below, the threshold value becomes and if the flow rate is minus, it turns off.