Positive displacement flowmeter for continuous flow measurement

Similar documents
Positive displacement flowmeter

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

INSERTION flow sensor for continuous flow measurement

Positive displacement batch controller

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller for On/Off control

INSERTION flowmeter with paddle wheel, ELEMENT design

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Paddle-wheel flow controller for On/Off control

Inductive conductivity meter

Insertion magnetic inductive flowmeter

Inductive conductivity meter

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

INLINE sensor-fitting with paddle wheel for flow measurement

INLINE fitting with paddle-wheel for flow measurement

Inline Paddle Wheel Flow Switch

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

macnaught flow measurement

INLINE fitting with paddle-wheel for flow measurement

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

Digital ph transmitter

OM004, OM006 & OM008 Oval Gear Meter

Digital ph transmitter

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

macnaught flow measurement

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

MX-SERIES OVAL GEAR FLOW METERS

OMP POSITIVE DISPLACEMENT FLOWMETERS

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

POSITIVE DISPLACEMENT FLOW METERS

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

POSITIVE DISPLACEMENT FLOW METERS

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

OMP Positive Displacement Flowmeters

Electrical position feedback for actuator sizes Ø mm

INSERTION Adaptor for analysis

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

2/2 or 3/2 way direct acting rocker solenoid valve

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

macnaught flow measurement

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

Positive Displacement Flowmeters GM020 series instruction manual

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Direct-acting 3/2 way plunger valve

RCM - Direct Reading Flowmeters

Simple float switch TCL001/8181

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

G2 Industrial Grade Meters

Positive Displacement Flowmeters GM020 series instruction manual

Industrial OG meter series IOG Inline and flanged oval gear meter

2/2 way Angle-Seat Valve for medium up to C, DN15-50

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Pneumatic control unit for decentralized automation of ELEMENT process valves

Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

DPT TARGET TYPE FLOWMETERS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Positive Displacement Flowmeters GM007 series instruction manual

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Types 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre

MODEL MX75 3 OVAL GEAR FLOWMETER

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Flow Controller, flow control system for gases

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

DTK. OEM Pelton Wheel Flow Sensor

I N S T R U C T I O N M A N U A L

3/2-way Solenoid Valve, direct-acting, NC or NO

MODEL MX12 1/2 OVAL GEAR FLOWMETER

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Positive Displacement Flowmeters GM515 series instruction manual

2/2-way Globe Control Valve, threaded port connection, DN 10-65

Flow Sensors & Instruments

SIGNET 7002 Vortex Flow Sensor ENGLISH

POSITIVE DISPLACEMENT FLOWMETERS

The experts in fluid technology

Turbotron // VTH15, VTM15, VTP15, VTI15

Transcription:

8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices in remote versions Type 8070 can be combined with... Type 8025 Type 8025 Konti-Dos Type 8611 Type 2712 (8630) PLC Flow transmitter remote version Batch control system econtrol Universal controller Continuous TopControl system The positive displacement flowmeter for continuous flow measurement is especially designed for use in highly viscous fluid like glue, honey or oil. It is made up of a compact sensor fitting (S070) with integrated oval rotor and an electronic module (SE30) with pulse signal (Hall transducer), quickly and easily connected together by a Quarter-Turn. The Bürkert designed fitting system ensures simple installation of the devices into all pipes from DN15 to DN100. The flowmeter produces frequency signal (pulse), proportional to the flow rate, which can easily be transmitted and processed by: - a Bürkert remote transmitter (Type 8025/8032...) - a batch control system 8025 Konti-Dos - a PLC Technical data General data Compatibility with sensor fittings S070 (see corresponding data sheet) Materials Housing, cover PC Cable plug PA Wetted parts materials Sensor fitting Aluminium, stainless steel (316F/1.4401) Rotor PPS, aluminium, stainless steel (316F/1.4401) Shaft / Seal Stainless steel / FKM or FEP/PTFE encapsulated Electrical connection Cable plug EN 175301-803 Connection cable max. 1.5 mm 2 cross section; max. 50 m length, shielded (for pulse sensor version) Complete device data (sensor fitting + electronic module) Pipe diameter DN15 to DN100 Measuring range Viscosity > 5 cps Viscosity < 5 cps Medium temperature max. Aluminium body Stainless steel body Fluid pressure max. DN15 DN25 DN40 / DN50 DN80 DN100 Viscosity Accuracy Repeatability 1) or in accordance to the value of the used flanges 1 to 1200 l/min (0.26 to 320 gpm) 3 to 616 l/min (0.78 to 320 gpm) 80 C (176 F) 100 C (212 F) 55 bar (798.05 PSI) (threaded process connection) 55 bar (798.05 PSI) 1) 18 bar (261.18 PSI) 12 bar (174.12 PSI) 10 bar (145.1 PSI) 1000 cps. max (higher on request) ±0.5% of Reading ±0.03% of Reading www.burkert.com p. 1/4

8070 Electrical data Operating voltage Pulse version Pulse Low Power version Current consumption with sensor Pulse version Pulse Low Power version Output: Frequency Pulse version Pulse Low Power version Reversed polarity of DC Environment Ambient temperature Relative humidity Standards and approvals Protection class Standard EMC Pressure (Sensor fitting S070, DN15 to DN100, in aluminium or stainless steel) 12-36 V DC, filtered and regulated 12-36 V DC filtered and regulated (via Bürkert transmitter) < 30 ma < 0.8 ma Transistor NPN/PNP, open collector, max. 100 ma, frequency: 0... 300 Hz; duty cycle 50% Transistor NPN, open collector, max. 10 ma, frequency: 0... 300 Hz; duty cycle 50% Protected 0 to +60 C (32 to 140 F) (operating and storage) 80%, without condensation IP65 with connector plugged-in and tightened EN 50081-1, 50082-2 Complying with article 3 of Chap. 3 from 97/23/CE directive.* (without CE mark) * For the 97/23/CE pressure directive, the device can only be used under following conditions (dependent on max. pressure, pipe diameter and fluid). Type of fluid Conditions Fluid group 1, chap. 1.3.a Forbidden Fluid group 2, chap. 1.3.a Fluid group 1, chap. 1.3.b Fluid group 2, chap. 1.3.b DN 32 or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 Design and principle of operation The flowmeter 8070 is built up with an electronic module SE30 associated to a sensor fitting S070 with integrated measurement oval rotor. This connection is made by means of a Quarter-Turn. Quarter-Turn Technology SE30 8070 In a 3-wire system (transistor output), the signal can be displayed or processed directly. The output signal is provided via cable plug according to EN 175301-803. S070 When liquid flows through the pipe, the rotors turn. This rotation produces a measuring signal in the transducer. The frequency and amplitude are proportional to the flow. A conversion coefficient (K factor, available in the instruction manual of the sensor fitting S070), specific to each pipe (size and material) enables the conversion of this frequency into a flow rate. Two electronic module versions with frequency output are available: - with one pulse output (either NPN or PNP transistor output). An external power supply of 12-36 V DC is required. It is designed for connection to any system with open collector NPN or PNP frequency input. - with one pulse Low Power output (NPN transistor output). An external power supply of 12-36 V DC is required. Can only be connected to separate versions of flow transmitters Type 8025/8032, to 4... 20 ma module Type 8023 or a universal controller econtrol Type 8611. Installation The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane (see figures to the right) and the flow of the fluid is in the direction of the arrow marked on the body. Correct The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system which would cause damages and to prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. Correct Incorrect p. 2/4

8070 Dimensions Orifice H 15 101 25 116 40 133 50 151 80 191 100 192 DN15 DN25 DN40 DN50 Threaded connection DN80 DN25 DN40 DN50 DN80 Flanged connection DN100 Ordering chart for flowmeter Type 8070 A flowmeter Type 8070 consists of: - an electronic module with pulse signal Type SE30 - an INLINE sensor fitting S070 (DN15 - DN100 - Refer to corresponding data sheet) Electronic module Type SE30 - for sensor fitting Type S070 (to be ordered separately) Description Operating voltage Output Electrical connection Pulse flowmeter version (pluggable to PLC) Pulse Low Power flowmeter version (only pluggable to Type 8025, 8032, 8023 or 8611) 12-36 V DC Frequency with pulse PNP or NPN, open collector from associated transmitter Frequency with pulse NPN, open collector Cable plug EN 175301-803 423 913 Cable plug EN 175301-803 423 914 p. 3/4

8070 Ordering chart for accessories for flowmeter Type 8070 (to be ordered separately) Version Specifications Operating voltage Outputs Relays Electrical connection Compatible remote transmitter Panelmounted Flow controller Type 8032 12-30 V DC NPN and NPN - Terminal strip 558 181 Universal flow transmitter Type 13-30 V DC 4... 20 ma (3- - Terminal strip 419 538 8025, 2 totalisators wire) + pulse 2 Terminal strip 419 537 Batch controller Type 8025, 12-30 V DC - 2 Terminal strip 419 536 2 totalisators and 1 flowrate Wallmounted Flow controller Type 8032 12-30 V DC NPN and NPN Free positionable 5-pin M12 male and 4-pin M12 female connectors 448 861 Universal flow transmitter Type 8025, 2 totalisators Batch controller Type 8025, 2 totalisators and 1 flowrate 13-30 V DC 4... 20 ma (3- - 3 cable glands 419 541 wire) + pulse 2 3 cable glands 419 540 115-230 V AC 4... 20 ma (3- - 3 cable glands 419 544 wire) + pulse 2 3 cable glands 419 543 13-30 V DC - 2 5 cable glands 433 740 115-230 V AC - 2 5 cable glands 433 741 Specifications 4-pin M12 female connector moulded on cable (2 m., shielded) 448 857 4-pin M12 female connector with plastic threaded locking ring 917 116 5-pin M12 female connector moulded on cable (2 m., shielded) 438 680 8-pin M12 female connector moulded on cable (2 m., shielded) 444 800 Interconnection possibilities with the flowmeter Type 8070 Type 8025 - Remote flow transmitter/ batch controller PLC Type 8032 - Remote flowmeter Type 8070 - Low Power Hall flowmeter with pulse signal NPN output Type 8070 - Hall flowmeter with pulse signal NPN /PNP output To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1209/5_EU-en_00891938 p. 4/4

S070 Positive displacement sensor fitting for continuous flow measurement DN15 to DN100 INLINE Quarter-Turn technology Electronics available for indication, monitoring, transmitting, On/Off control and batch control Type S070 can be combined for... Type 8070 Type 8072 Type 8075 Type 8076 Positive displacement flowmeter Positive displacement flowmeter Positive displacement flowmeter Positive displacement flowmeter This positive displacement sensor fitting is specially designed for flow measurement and/or batch control of highly viscous fluids like glue, honey or oil. This measuring element must be associated to an electronic module SE30, SE32, SE35, SE36 with hall sensor principle only, quickly and easily connected together by a Quarter-Turn. The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design. The low pressure drop and high pressure rating make it suitable for both gravity and pump (in-line) applications. General data Compatibility Wetted parts materials Body Rotor Shaft Seal Environment Ambient temperature With electronic SE30, SE32, SE35, SE36 with Hall sensor principle (see separate data sheet) Aluminium, stainless steel (316F) PPS, aluminium, stainless steel (316F) Stainless steel (316F) FKM or FEP/PTFE encapsulated 0 to 60 C (32 to 140 F) (operation and storage) Standards, directives and approvals Protection class IP66 (NEMA 6) Directives Pressure Complying with article 3 of 3 from 97/23/CE directive*. (without CE mark) * For the 97/23/CE pressure directive, the device can only be used under following conditions (dependent on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.b Fluid group 2, 1.3.b Conditions Forbidden DN 32, or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 Complete device data Pipe diameter Thread connection Flange connection Measuring range Viscosity > 5 cps Viscosity < 5 cps Medium temperature max. Medium pressure max. DN15 DN25 DN40/DN50 DN80 DN100 Viscosity Max. particle size Accuracy Repeatibility 1) or in accordance to the value of the used flanges DN15 to DN100 ½ ; 1 ; 1½ ; 2 ; 3 (G or NPT) 25; 40; 50; 80 or 100 mm DIN PN16 flange 1 ; 1½; 2 ; 3 or 4 ANSI 150LB flange 2 to 1200 l/min (0.26 to 320 gpm) 3 to 616 l/min (0.78 to 160 gpm) Aluminium body: 80 C (176 F) Stainless steel body: 120 C (248 F) 55 bar (798.05 PSI) (threaded process connection) 55 bar (798.05 PSI) 1) 18 bar (261.18 PSI) 12 bar (174.12 PSI) 10 bar (145.1 PSI) 1000 cps. max. (higher on request) 250 m - To prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. ±0.5% of Reading ±0.03% of Reading www.burkert.com p. 1/4

S070 Installation and operation The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane (see figures to the right) and the flow of the fluid is in the direction of the arrow marked on the body. Correct The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system which would cause damages and to prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. Correct Incorrect When fluid passes through the fitting, rotors turn. This rotation produces a measuring frequency in the associated hall sensor, which is proportional to the flow. Dimensions [mm] Threaded connection Orifice DN A B C D E Stainless steel Aluminium 15 96 100 100 61 20 55 25 112 143 133 91 35 85 40 144 124 124 120 45 112 50 178 210 210 150 55 140 80 220 260 302 212 77 202 Flanged connection Orifice DN A B B C D E F G H J K L Stainless Steel Al. DIN ANSI DIN ANSI 25 112 291 294 281 284 91 35 115 16 108 16.0 1.6 1.6 85 40 144 262 270 262 270 120 45 150 16 127 17.5 1.6 1.6 112 50 178 264 264 264 264 150 55 165 18 152 19.0 1.6 1.6 140 80 220 344 348 436 436 212 77 200 22 191 22.5 1.6 1.6 202 100 291 382 390 578 578 230 108 220 22 229 22.5 1.6 1.6 234 p. 2/4

S070 Ordering chart for sensor fitting Type S070 Orifice DN Process connection Flow Range > 5 cps < 5 cps 15 G ½ 2-30 l/min 3-25 l/min Aluminium PPS FKM 443 985 Body material Rotor material Stainless steel Stainless steel FEP/PTFE 443 990 NPT ½ 2-30 l/min 3-25 l/min Aluminium PPS FKM 443 995 Stainless steel Stainless steel FEP/PTFE 444 000 25 G 1 6-120 l/min 10-100 l/min Aluminium PPS FKM 443 986 Stainless steel Stainless steel FEP/PTFE 443 991 NPT 1 6-120 l/min 10-100 l/min Aluminium PPS FKM 443 996 Stainless steel Stainless steel FEP/PTFE 444 001 25 mm DIN PN16 flange 6-120 l/min 10-100 l/min Aluminium PPS FKM 553 637 Stainless steel Stainless steel FEP/PTFE 553 634 1 ANSI 150 LB flange 6-120 l/min 10-100 l/min Aluminium PPS FKM 553 636 Stainless steel Stainless steel FEP/PTFE 553 633 40 G 1½ 10-250 l/min 15-235 l/min Aluminium PPS FKM 443 987 Stainless steel Stainless steel FEP/PTFE 443 992 NPT 1½ 10-250 l/min 15-235 l/min Aluminium PPS FKM 443 997 Stainless steel Stainless steel FEP/PTFE 444 002 40 mm DIN PN16 flange 10-250 l/min 15-235 l/min Aluminium PPS FKM 443 988 Stainless steel Stainless steel FEP/PTFE 443 993 1 1/2 ANSI 150 LB flange 10-250 l/min 15-235 l/min Aluminium PPS FKM 443 998 Stainless steel Stainless steel FEP/PTFE 444 003 50 G 2 15-350 l/min 30-300 l/min Aluminium PPS FKM 553 640 NPT 2 15-350 l/min 30-300 l/min Aluminium PPS FKM 553 641 50 mm DIN PN16 flange 15-350 l/min 30-300 l/min Aluminium PPS FKM 443 989 Stainless steel Stainless steel FEP/PTFE 443 994 2 ANSI 150 LB flange 15-350 l/min 30-300 l/min Aluminium PPS FKM 443 999 Stainless steel Stainless steel FEP/PTFE 444 004 80 G 3 20-733 l/min 66-616 l/min Aluminium Aluminium FKM 553 642 NPT 3 20-733 l/min 66-616 l/min Aluminium Aluminium FKM 553 643 80 mm DIN PN16 flange 20-733 l/min 66-616 l/min Aluminium Aluminium FKM 553 645 3 ANSI 150 LB flange 20-733 l/min 66-616 l/min Aluminium Aluminium FKM 553 644 100 100 mm DIN PN16 flange 120-1200 l/min --- Aluminium Aluminium FKM 553 647 4 ANSI 150 LB flange 120-1200 l/min --- Aluminium Aluminium FKM 553 646 Seal Ordering chart for spare parts for sensor fitting S070 Description Orifice Size [mm] [inch] Materials Rotor DN15 ½ PPS 550 933 Stainless steel 550 934 DN25 1 PPS 550 937 Stainless steel 550 938 DN40 1 ½ PPS 550 941 Stainless steel 550 942 DN50 2 PPS 550 945 Stainless steel 550 946 Description Orifice Size [mm] [inch] Materials O-ring DN15 ½ FEP/PTFE 550 929 FKM 550 930 DN25 1 FEP/PTFE 550 935 FKM 550 936 DN40 1 ½ FEP/PTFE 550 939 FKM 550 940 DN50 2 FEP/PTFE 550 943 FKM 550 944 p. 3/4

S070 Interconnection possibilities with other Bürkert products Transmitter/Controller remote version Compact transmitter Type SE32* Flow switch/ transmitter Type 8025 Flow transmitter/ batch controller Type SE35* Flow transmitter/ batch controller Type SE36 Flow transmitter Type 8032 Flow switch/transmitter Intrinsic safety barrier Type SE30* Flow transmitter Type SE30 Ex - Flow transmitter Fitting with oval rotor Type S070 INLINE sensor fitting * Use only version with Hall transducer To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1209/7_EU-en_00891837 p. 4/4