CDN Resource Laboratories Ltd.

Similar documents
AMIS0448. Certified Reference Material. Platinum (PGM) Platreef Ore Bushveld Complex, South Africa

CERTIFICATE VO SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

QC CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

AMIS0318. Certified Reference Material. Certificate of Analysis

Certificate of Anatfrb. multi-element standard, Bakouma, Central African Republic. AMrS0054. Certifi ed Con ce ntrati o n s

AMIS0454 Certified Reference Material. Certificate of Analysis

AMIS0388. Certified Reference Material. Certificate of Analysis

AMIS0257 Certified Reference Material. Certificate of Analysis

Quality Control in Mineral Exploration

Appendix DRA. THE EFFECTS OF WEATHERING ON THE COMPOSITION OF A SENTINEL BLUFFS MEMBER FLOW (GRANDE RONDE BASALT)

GeoPT26 AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 26 (Ordinary Portland Cement, OPC-1) / Jan 2010

DATA REPOSITORY. Table DR1. Coring sites. Table DR2. Geochemistry of tephra grains. Table DR3. Geochemistry of tephra standards

TRACE ELEMENTS IN URINE. Event #3, 2012

Ambient PM 10 Monitoring Sechelt, B.C Update

TEMPERATURE RISE TESTS

SPECTRO XRF Report SPECTRO XEPOS. Analysis of Raw Material prepared as Fused Bead in the Cement Industry. Summary

TRACE ELEMENTS IN URINE

Rio Alto completes 2014 oxide drilling program at La Arena

TRACE ELEMENTS IN WHOLE BLOOD. Event #2, 2010

ATILH, Frankreich - Zement 16/3215/06

Combustion and Boiler Performance Assessment of Kardia Power Plant

WESTONE ONYX BLACK WEI-408B2

To the participants of AQS Baden-Württemberg Dear Madam or Sir,

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

The San Juan Mine has been developed and production will commence during the fourth quarter at a rate of tpd.

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Incinerator Monitoring Program Ash Characterization Summary

Successful Implementation of Cormetech Catalyst. in High Sulfur Coal-Fired SCR Demonstration Project

QUALITY ASSURANCE & LAB ACCREDITATION

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

GC MERGE OF LIGHT ENDS WITH ASTM D7169 BOILING POINT DISTRIBUTION

Water analysis, QC and more:

Voting Draft Standard

Fission Winter Program; 26.41% U3O8 over 12.0m (line 855E); Three New High-Grade Holes

Evaluation of Bruker s Tracer Family Factory Obsidian Calibration for Handheld Portable XRF Studies of Obsidian

Headwaters Resources Performance Pozzolan

Incinerator Monitoring Program Ash Characterization Summary

Set-Up Guide. Part # , Rev 1.0, Sep

ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION

Backup Power. Renewable Resources. Fleet Fueling. Industrial Applications Community Fueling. Personal Energy Station

Page. Table of Contents. 2 SAE 100R5 HOSE: 151 & 151H Bulk Hose...3 Reusable Fittings...3-4

Transatlantic Mining Corporation Kearsarge Drilling Update.

GeoPT 32, England - WG-1, Woodstock Basalt

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

Licence Application Decision

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

Product Evaluation Report

Elliot Lake Research Field Station Swastika Ore Samples from Good Mining Three Acid Digest with ICP-MS Analysis

Calibration & Verification Standards

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

Water Consumption Statistics Report

lubricants analysis. complete solutions for your lab. Lubricants Analysis

ASTM International: Proficiency Test Programs and Technical and Professional Training Courses

Pursuing high precision, speed, and ease of use

MAJOR- AND TRACE-ELEMENT GEOCHEMICAL DATA FROM THE PANTS LAKE INTRUSIONS AND SPATIALLY ASSOCIATED ROCK UNITS, CENTRAL LABRADOR (NTS 13M AND 13N)

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

THE ROLE OF AN AUTO RECYCLER IN NORTH AMERICA

The National Marine Biological Analytical Quality Control Scheme

The National Marine Biological Analytical Quality Control Scheme

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Toxics Substance Reduction Plan Summary For

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

CMP266 Removal of Demand TNUoS charging as a barrier to future elective Half Hourly settlement

2012 Water Consumption Statistics Report. Water Services Department

DETAIL SPECIFICATION SHEET SLEEVE, SWAGING-WIRE ROPE

Obtaining ASTM D6400- D6868 Approval

BUREAU OF MINERAL RESOURCES, GEOLOGY AND GEOPHYSICS

Hospitality SeatingTM

CUSC Panel 30 September 2016 John Martin National Grid

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Measure of all Things. Volumetric Solutions from Merck

2016 MASTER CATALOGUE

INTERPRETATION OF USED COOLANT ANALYSIS

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005.

ISO INTERNATIONAL STANDARD

An Overview of Warn Range Administrative Licence Suspension Programs in Canada 2010

The Metso series of. Mill discharge pumps. Innovative sustainable technology

HIGH TEMPERATURE SUSTAINED LOAD TEST ON A COMPRESSION DEAD-END CONNECTOR INSTALLED ON 1020 KCMIL, ACCC/TW DRAKE CONDUCTOR

Country Contract Price. Contract # or. Location. (exclusive of HST) (PROVINCE/

New Challenges for the Transatlantic Cooperation N. LOHL, EASA

thousands of PLN a b c d e f g h i j k l

Supplementary Table 4. U-Pb geochronology of detrital zircons from the Kobuk Koyukuk Basin

Global Economic Briefing: Merchandise Trade

Next Release: 16 May Next Release: 16 May January

APPENDIX 1: FIGURE 3 COLOR VERSION

breakthrough versatility

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE

White Paper: Ensure Accuracy and Maximize the Value of Your Cable Testing Equipment with Calibration from Fluke Networks

Specifications for Refrigerants

Title 29: MOTOR VEHICLES

COUNTY OF ROCKLAND Department of General Services Purchasing Division

MEASURES TO IMPROVE AIR QUALITY IN THE SUBWAY SYSTEM

LUBRICANT (OIL) ANALYSIS COMPARISON

Transcription:

CDN Resource Laboratories Ltd. #2, 20148 102nd Ave, Langley, B.C., Canada, V1M 4B4, 604-882-8422, Fax: 604-882-8466 (www.cdnlabs.com) REFERENCE MATERIAL: CDN-ME-1606 Recommended values and the Between Lab Two Standard Deviations Gold 1.069 ± 0.092 30 g FA, instrumental Certified value Silver 114 ppm ± 7 ppm 30 g FA, gravimetric Certified value Silver 116 ppm ± 5 ppm 4-Acid / ICP Certified value Copper 0.197 % ± 0.008 % 4 Acid / ICP Certified value Lead 1.76 % ± 0.06 % 4 Acid / ICP Certified value Zinc 0.60 % ± 0.02 % 4 Acid / ICP Certified value Note: Standards with an RSD of near or less than 5% are certified; RSD s of between 5% and 15% are Provisional; RSD s over 15% are Indicated. Provisional and Indicated values cannot be used to monitor accuracy with a high degree of certainty. PREPARED BY: CDN Resource Laboratories Ltd. CERTIFIED BY: Duncan Sanderson, B.Sc., Licensed Assayer of British Columbia INDEPENDENT GEOCHEMIST: Dr. Barry Smee., Ph.D., P. Geo. DATE OF CERTIFICATION: April 28, 2017 ORIGIN OF REFERENCE MATERIAL: Standard CDN-ME-1606 was prepared by combining a variety of low and high grade ores. METHOD OF PREPARATION: Reject ore material was dried, crushed, pulverized and then passed through a 270-mesh screen. The +270 material was discarded. The -270 material was mixed for 5 days in a double-cone mixer. Splits were taken and sent to 15 commercial laboratories for round robin assaying. Approximate chemical composition (from whole rock analysis) is as follows: Percent Percent SiO2 61.1 Na2O 0.3 Al2O3 8.8 MgO 3.0 Fe2O3 11.5 K2O 1.4 CaO 2.2 TiO2 0.3 MnO 0.3 LOI 8.0 S 4.8 C 1.2 Statistical Procedures: The final limits were calculated after first determining if all data was compatible within a spread normally expected for similar analytical methods done by reputable laboratories. Data from any one laboratory was removed from further calculations when the mean of all analyses from that laboratory failed a t test of the global means of the other P a g e 1 5

laboratories. The means and standard deviations were calculated using all remaining data. Any analysis that fell outside of the mean ±2 standard deviations was removed from the ensuing data base. The mean and standard deviations were again calculated using the remaining data. This method is different from that used by Government agencies in that the actual between-laboratory standard deviation is used in the calculations. This produces upper and lower limits that reflect actual individual analyses rather than a grouped set of analyses. The limits can therefore be used to monitor accuracy from individual analyses, unlike the Confidence Limits published on other standards. Assay Procedures: : Ag: Cu, Pb, Zn: Fire assay pre-concentration, AA or ICP finish. Fire assay pre-concentration, Gravimetric Finish, and 4-acid digestion, AA or ICP finish. 4-acid digestion, AA or ICP finish. Results from round-robin assaying: ME-1606-1 1.12 1.02 1.12 1.11 1.10 1.16 1.07 1.10 1.11 1.03 1.05 1.05 1.10 1.06 1.01 ME-1606-2 1.14 1.05 1.06 1.07 1.15 1.03 1.01 1.14 1.11 0.99 1.09 1.10 1.14 0.98 0.99 ME-1606-3 1.12 1.02 1.07 1.12 1.07 1.18 0.96 1.16 1.09 1.05 1.06 1.09 1.08 1.03 1.08 ME-1606-4 1.14 1.05 1.03 1.01 1.10 1.08 1.04 1.16 1.03 1.05 1.11 1.08 1.12 1.01 1.04 ME-1606-5 1.10 0.98 1.13 0.99 1.07 1.10 0.99 1.10 1.03 1.03 1.09 1.08 1.07 0.99 1.06 ME-1606-6 1.11 1.03 1.05 1.08 1.05 1.04 0.97 1.13 1.06 1.00 1.05 1.15 1.05 1.09 0.95 ME-1606-7 1.12 0.98 1.06 1.06 1.06 1.11 1.06 1.18 1.11 0.99 1.02 1.15 1.06 1.14 0.98 ME-1606-8 1.14 1.00 1.08 1.03 1.07 1.05 1.09 1.13 1.08 1.07 1.02 1.09 1.07 1.05 1.04 ME-1606-9 1.10 0.99 1.11 1.13 1.13 1.03 1.03 1.12 1.09 1.08 1.03 1.11 1.12 1.10 1.04 ME-1606-10 1.12 1.04 1.06 1.05 1.08 1.03 1.02 1.14 1.04 1.00 1.03 1.08 1.09 1.10 1.09 Mean 1.12 1.02 1.08 1.06 1.09 1.08 1.02 1.14 1.07 1.03 1.06 1.10 1.09 1.06 1.03 Std. Devn. 0.0147 0.0276 0.0336 0.0468 0.0323 0.0572 0.0427 0.0248 0.0322 0.0325 0.0314 0.0316 0.0280 0.0528 0.0449 % RSD 1.31 2.72 3.12 4.41 2.97 5.31 4.17 2.18 3.00 3.16 2.97 2.87 2.57 5.00 4.37 P a g e 2 5

Gravimetric Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag ME-1606-1 113 121 116 109 114 114 117 106 115 111 109 114 118 105 ME-1606-2 112 119 117 112 114 113 120 108 115 110 110 117 116 110 ME-1606-3 114 119 117 115 113 114 116 114 116 109 113 116 117 110 ME-1606-4 115 118 119 114 110 109 117 111 115 111 115 116 110 110 ME-1606-5 112 116 116 113 108 109 118 112 116 110 118 115 120 110 ME-1606-6 114 115 116 111 109 112 121 107 116 110 104 114 112 103 ME-1606-7 114 120 117 112 117 112 120 107 117 110 103 113 113 102 ME-1606-8 114 116 117 104 117 109 113 111 114 112 112 115 112 103 ME-1606-9 115 120 117 112 113 115 120 111 116 110 108 114 118 117 ME-1606-10 113 117 119 117 115 112 115 113 114 111 109 115 112 115 Mean 113 118 117 112 113 112 118 110 115 110 110 115 115 108 Std. Devn. 1.0750 2.0248 1.0231 3.5418 3.1269 2.2336 2.5841 2.7889 0.9140 0.8433 4.6296 1.1972 3.3928 5.1478 % RSD 0.95 1.71 0.87 3.17 2.77 2.00 2.20 2.54 0.79 0.76 4.20 1.04 2.96 4.74 Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag Ag ME-1606-1 118 117 114 114 116 114 118 120 121 110 120 115 116 120 ME-1606-2 118 117 112 116 118 112 118 118 120 113 114 114 115 119 ME-1606-3 117 120 114 121 115 115 121 118 123 113 116 114 118 117 ME-1606-4 117 116 113 120 116 113 116 116 124 111 114 112 119 117 ME-1606-5 116 118 112 117 116 113 117 117 118 112 113 110 118 116 ME-1606-6 119 117 114 120 114 114 119 119 119 114 121 110 116 121 ME-1606-7 116 118 116 118 111 111 121 117 120 113 118 114 116 120 ME-1606-8 117 116 111 119 115 114 116 115 118 113 115 115 116 119 ME-1606-9 118 119 111 116 115 114 117 115 124 116 121 114 117 118 ME-1606-10 118 116 112 117 115 113 118 117 119 112 112 115 117 119 Mean 117 117 113 118 115 113 118 117 121 113 116 113 117 119 Std. Devn. 0.9661 1.3499 1.5515 2.2010 1.7920 1.1595 1.7920 1.6193 2.3190 1.6364 3.3731 1.9465 1.2293 1.5776 % RSD 0.82 1.15 1.37 1.87 1.56 1.02 1.52 1.38 1.92 1.45 2.90 1.72 1.05 1.33 Notes: Laboratory 7 did not report fire assay, gravimetric data for Ag. Laboratory 6 did not report 4-acid instrumental data for Ag. P a g e 3 5

Results from round-robin assaying: % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu % Cu ME-1606-1 0.21 0.192 0.191 0.196 0.203 0.192 0.194 0.197 0.200 0.201 0.190 0.19 0.199 0.195 0.202 ME-1606-2 0.20 0.191 0.190 0.196 0.203 0.202 0.187 0.199 0.199 0.202 0.200 0.20 0.198 0.196 0.200 ME-1606-3 0.21 0.191 0.197 0.202 0.204 0.203 0.190 0.202 0.202 0.199 0.190 0.19 0.197 0.200 0.197 ME-1606-4 0.21 0.199 0.194 0.200 0.197 0.194 0.182 0.198 0.201 0.203 0.200 0.20 0.198 0.197 0.195 ME-1606-5 0.21 0.191 0.193 0.199 0.196 0.192 0.182 0.198 0.200 0.203 0.190 0.19 0.196 0.198 0.200 ME-1606-6 0.21 0.195 0.196 0.203 0.195 0.200 0.193 0.196 0.200 0.202 0.200 0.20 0.198 0.196 0.199 ME-1606-7 0.21 0.195 0.196 0.199 0.194 0.200 0.183 0.196 0.197 0.202 0.200 0.20 0.201 0.201 0.202 ME-1606-8 0.21 0.195 0.193 0.200 0.198 0.195 0.187 0.199 0.196 0.200 0.200 0.19 0.198 0.194 0.201 ME-1606-9 0.21 0.196 0.190 0.195 0.198 0.199 0.194 0.196 0.194 0.203 0.200 0.19 0.198 0.196 0.200 ME-1606-10 0.21 0.194 0.190 0.195 0.197 0.197 0.192 0.197 0.199 0.201 0.200 0.20 0.202 0.197 0.197 Mean 0.209 0.194 0.193 0.199 0.199 0.197 0.188 0.198 0.199 0.202 0.197 0.195 0.199 0.197 0.199 Std. Devn. 0.0032 0.0026 0.0028 0.0029 0.0036 0.0040 0.0049 0.0018 0.0024 0.0013 0.0048 0.0053 0.0018 0.0022 0.0023 % RSD 1.51 1.36 1.44 1.45 1.80 2.03 2.59 0.89 1.23 0.67 2.45 2.70 0.90 1.10 1.16 % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb % Pb ME-1606-1 1.85 1.71 1.685 1.71 1.78 1.700 1.870 1.741 1.775 1.757 1.730 1.83 1.792 1.75 1.82 ME-1606-2 1.85 1.80 1.713 1.72 1.79 1.715 1.86 1.765 1.770 1.753 1.75 1.79 1.804 1.76 1.78 ME-1606-3 1.84 1.72 1.752 1.77 1.80 1.715 1.81 1.749 1.760 1.736 1.75 1.79 1.817 1.77 1.76 ME-1606-4 1.85 1.72 1.735 1.77 1.80 1.685 1.82 1.743 1.775 1.745 1.76 1.82 1.796 1.77 1.76 ME-1606-5 1.85 1.75 1.721 1.78 1.81 1.695 1.76 1.746 1.755 1.764 1.76 1.78 1.805 1.79 1.76 ME-1606-6 1.85 1.74 1.752 1.77 1.78 1.690 1.87 1.756 1.765 1.745 1.76 1.82 1.792 1.78 1.78 ME-1606-7 1.85 1.75 1.757 1.77 1.78 1.710 1.78 1.745 1.745 1.757 1.79 1.79 1.782 1.79 1.79 ME-1606-8 1.84 1.70 1.723 1.77 1.80 1.710 1.82 1.740 1.735 1.733 1.78 1.80 1.784 1.78 1.79 ME-1606-9 1.84 1.73 1.711 1.71 1.80 1.700 1.82 1.734 1.750 1.759 1.81 1.81 1.803 1.76 1.79 ME-1606-10 1.85 1.75 1.726 1.74 1.80 1.715 1.80 1.739 1.740 1.725 1.79 1.81 1.804 1.77 1.78 Mean 1.847 1.74 1.727 1.75 1.794 1.704 1.82 1.746 1.757 1.747 1.768 1.804 1.798 1.77 1.781 Std. Devn. 0.0048 0.0283 0.0224 0.0268 0.0107 0.0111 0.0370 0.0091 0.0144 0.0128 0.0239 0.0165 0.0107 0.0132 0.0185 % RSD 0.26 1.63 1.30 1.53 0.60 0.65 2.03 0.52 0.82 0.73 1.35 0.91 0.60 0.74 1.04 % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn % Zn ME-1606-1 0.61 0.59 0.586 0.61 0.63 0.594 0.620 0.599 0.631 0.600 0.57 0.59 0.632 0.60 0.60 ME-1606-2 0.61 0.59 0.585 0.62 0.64 0.622 0.59 0.600 0.621 0.605 0.57 0.59 0.636 0.60 0.59 ME-1606-3 0.60 0.60 0.602 0.63 0.63 0.609 0.58 0.610 0.631 0.597 0.57 0.58 0.629 0.61 0.59 ME-1606-4 0.61 0.61 0.595 0.63 0.60 0.608 0.59 0.601 0.630 0.607 0.57 0.60 0.599 0.60 0.59 ME-1606-5 0.60 0.59 0.593 0.63 0.60 0.601 0.59 0.608 0.620 0.606 0.58 0.59 0.607 0.61 0.59 ME-1606-6 0.60 0.60 0.603 0.64 0.59 0.612 0.61 0.603 0.625 0.597 0.57 0.61 0.608 0.61 0.60 ME-1606-7 0.60 0.60 0.602 0.63 0.59 0.623 0.60 0.601 0.617 0.605 0.58 0.60 0.610 0.61 0.60 ME-1606-8 0.60 0.61 0.592 0.63 0.60 0.603 0.61 0.603 0.613 0.598 0.59 0.60 0.597 0.61 0.60 ME-1606-9 0.60 0.60 0.587 0.61 0.60 0.615 0.60 0.604 0.618 0.604 0.59 0.60 0.595 0.61 0.60 ME-1606-10 0.60 0.60 0.592 0.62 0.60 0.623 0.60 0.607 0.619 0.601 0.58 0.60 0.598 0.60 0.60 Mean 0.603 0.60 0.594 0.62 0.608 0.611 0.60 0.603 0.623 0.602 0.577 0.596 0.611 0.61 0.596 Std. Devn. 0.0048 0.0065 0.0066 0.0096 0.0181 0.0100 0.0120 0.0037 0.0064 0.0039 0.0082 0.0084 0.0156 0.0053 0.0056 % RSD 0.80 1.08 1.10 1.55 2.98 1.63 2.00 0.61 1.03 0.64 1.43 1.41 2.55 0.88 0.93 P a g e 4 5

Notes: Cu data from laboratory 1 was removed for failing the t test. Pb data from laboratory 1 was removed for failing the t-test. Zn data from laboratory 11 was removed for failing the t-test. Participating Laboratories: (not in same order as table of assays) Legal Notice: Bureau Veritas, Vancouver, BC, Canada Activation Laboratories, Ancaster, Ontario, Canada Activation Laboratories, Thunder Bay, Ontario, Canada ALS Canada, North Vancouver, BC, Canada ALS, Loughrea, Ireland ALS, Lima, Peru Argetest, Ankara, Turkey Certimin S.A., Lima, Peru AGAT Labs, Mississauga, Ontario, Canada MS Analytical, Langley, BC, Canada SGS, Vancouver, BC, Canada SGS, Lima, Peru SGS, Lakefield, Ontario, Canada TSL Laboratories Ltd., Saskatoon, SK, Canada Andes Analytical Assay Ltda., Santiago, Chile This certificate and the reference material described in it have been prepared with due care and attention. However CDN Resource Laboratories Ltd. or Barry Smee accept no liability for any decisions or actions taken following the use of the reference material. Our liability is limited solely to the cost of the reference material. Certified by Duncan Sanderson, Certified Assayer of B.C. Geochemist Dr. Barry Smee, Ph.D., P. Geo. P a g e 5 5