Manual motor starter MS116

Similar documents
Manual motor starter MS116

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter magnetic only MO325

Manual motor starter MS132

Thermal overload relay TF65 and TF96

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relays EF205 and EF370

Electronic overload relay EF65, EF96 and EF146

Mini contactors B6, BC6 with 3 pole

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Thermal Overload Relays

Phone: Fax: Web: -

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Short form catalogue Motor protection and control Manual motor starters

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Selective main circuit breakers S 750 series Technical Data

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starters Overview and benefits

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

MS General Information Extended Product Type: MS

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

MS25, MST25, MS20, MST20

Data Sheet Manual Motor Starters Ex9SN Series

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX DG/S x DALI-Gateway Basic

AF40... AF96 3-pole contactors Technical data

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Technical data for manual motor starters Type MS325

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Technical Information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

DBL distribution blocks 3x1 pole

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

Technical Information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

ZS4-PE Screw Clamp Terminal Blocks Ground

Short form catalogue. Motor protection & control

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Mini Contactors Applications and Segments

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

Manual Motor Starter MS 116. Technical Catalogue

D509E. Manual Motor - Starters

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

Panorama. Contactors Motor protection Accessories

ZP2.5-PE Spring Terminal Block Ground

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

Data Sheet Manual Motor Starter Ex9S32 Series

ASL09..S 3-pole Contactors - Spring Terminals

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS50-PE Screw Clamp Terminal Blocks Ground

Data Sheet Manual Motor Starter Ex9S32 Series

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-PE Screw Clamp Terminal Blocks Ground

Technical Information

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZP2.5-4P Spring Terminal Block Feed-through

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Transcription:

Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under shortcircuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors. 2CDC241001V0013 Description Overload protection trip class 10 Phase loss sensitivity Disconnect function Temperature compensation from -25 +55 C djustable current setting for overload protection Suitable for three- and single-phase application Trip-free mechanism Clear switch position indication ON/OFF Order data MS116 screw terminal Setting range Type Trip class Order code Packing unit Weight per PCE PCE kg 0.10...0.16 MS116-0.16 10 1SM250000R1001 1 0.225 0.16...0.25 MS116-0.25 10 1SM250000R1002 1 0.225 0.25...0.40 MS116-0.4 10 1SM250000R1003 1 0.225 0.40...0.63 MS116-0.63 10 1SM250000R1004 1 0.225 0.63...1.00 MS116-1.0 10 1SM250000R1005 1 0.225 1.00...1.60 MS116-1.6 10 1SM250000R1006 1 0.265 1.60...2.50 MS116-2.5 10 1SM250000R1007 1 0.265 2.50...4.00 MS116-4.0 10 1SM250000R1008 1 0.265 4.00...6.30 MS116-6.3 10 1SM250000R1009 1 0.265 6.30...10.0 MS116-10 10 1SM250000R1010 1 0.265 8.00...12.0 MS116-12 10 1SM250000R1012 1 0.265 10.0...16.0 MS116-16 10 1SM250000R1011 1 0.265 16.0...20.0 MS116-20 10 1SM250000R1013 1 0.310 20.0...25.0 MS116-25 10 1SM250000R1014 1 0.310 25.0...32.0 MS116-32 10 1SM250000R1015 1 0.310 Note: MS116 with pre-assembled auxiliary contact HKF1-11, please order as follow 1SM250005Rxxxx

Functional description 1 Terminals 1L1, 3L2, 5L3 1 2 Test function 3 Current setting range / djustable current setting for overload protection 4 Terminals 2T1, 4T2, 6T3 2CDC242032F0013 2 3 4 pplication The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for shortcircuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads. The manual motor starters have a setting scale in amperes, which allows the direct adjusting of the device without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current). Operation mode 2CDC242023F0009 2CDC242028F0013 2CDC242024F0009 Single-phase operation Single-phase operation Three-phase operation Wiring diagram 1L1 3L2 5L3 2T1 4T2 6T3 2CDC242025F0009 2-2CDC131025D0202

a Resistance and power loss per pole Type Setting range Resistance per pole Power loss per pole lower value upper value Ω at lower value W at upper value W MS116-0.16 0.10 0.16 66.00 0.7 1.7 MS116-0.25 0.16 0.25 25.50 0.7 1.7 MS116-0.4 0.25 0.40 10.38 0.7 1.7 MS116-0.63 0.40 0.63 4.36 0.7 1.7 MS116-1.0 0.63 1.00 1.605 0.7 1.7 MS116-1.6 1.00 1.60 0.648 0.7 1.7 MS116-2.5 1.60 2.50 0.292 0.7 1.8 MS116-4.0 2.50 4.00 0.114 0.7 1.8 MS116-6.3 4.00 6.30 0.046 0.7 1.8 MS116-10 6.30 10.0 0.024 0.9 2.4 MS116-12 8.00 12.0 0.016 1.0 2.3 MS116-16 10.0 16.0 0.011 1.1 2.8 MS116-20 16.0 20.0 0.0057 1.5 2.3 MS116-25 20.0 25.0 0.0045 1.8 2.8 MS116-32 25.0 32.0 0.0030 1.9 3.1 Technical diagram (Op/h) 140 120 100 switching frequency 80 60 40 20 t a = 3 s t a = 1.5 s t a = 5 s t a = 1 s t = 0.5 s 0 0 20 40 60 80 100 (%) duty ratio 2CDC232005F0211 Intermittent periodic duty, t a : Motor starting time 2CDC131025D0202-3

Dimensions in mm / inches 1.5 0.06" 5.5 0.22" 80.1 3.15" 70 2.76" 43.5 1.71" 1.5 0.06" 5.5 0.22" 79.9 3.15" 69.8 2.75" 43.3 1.7" 90 3.54" 1.7 0.07" 27.5 1.1" 75 2.95" 35 1.38" 45 1.77" 57.8 2.3" 97.8 3.85" 1.7 0.07" 27.5 1.1" 75 2.95" 35 1.38" 45 1.77" 57.8 2.3" 14 0.55" 14 45 1.77" 0.55" 2CDC242002F0010 14 0.55" 14 0.55" 45 1.77" 2CDC242001F0011 MS116 16 MS116 20 Ø 4.5 Ø 0.18" 9 0.35" 5.4 0.21" Ø 4.5 Ø 0.18" 9 0.35" 5.4 0.21" 122 110 122 110 4.8" 4.33" 4.8" 4.33" 17.5 0.69" 2CDC242003F0010 17.5 0.69" 2CDC242002F0011 MS116 16 with screw fixing kit FS116 (accessory) MS116 20 with screw fixing kit FS116 (accessory) 4-2CDC131025D0202

Main accessories for manual motor starter S1-M2-25 PS1-..-65 3-phase busbar up to 65 S1-M1-25 PS1-..-65 BS1-3 S1-M1-25 3-phase busbar up to 100 PS1-..-100 HK1 SK1 BS1-3 HK1 HK1 SK1 S1 CK1 MS116 1 HK1 CK1 U1 MS132 HKF1-11 1SBC500341F0000 2CDC131025D0202-5

Technical data IEC/EN Data at T = 40 C and at rated values, if nothing else indicated Main circuit 1L1-3L2-5L3 2T1-4T2-6T3 Rated operational voltage U e 690 V C - V DC Setting range - thermal overload protection see table Order data on page 1 Rated operational current I e see table below Rated instantaneous short-circuit current setting I i see table below Rated service short-circuit breaking capacity I cs see table Short-circuit breaking capacity and backup Rated ultimate short-circuit breaking capacity I cu fuses on page 8 Trip class see table Order data on page 1 Rated frequency 50/60 Hz Number of poles 3 Resistance per pole see table Resistance and power loss per pole on Power loss per pole page 3 Isolation data Rated impulse withstand voltage U imp 6 kv Rated insulation voltage U i 690 V Pollution degree 3 Electrical connection MS116 16 MS116 20 Connecting capacity solid 1/2 x 1... 4 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² stranded 1/2 x 1... 4 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² flexible with ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 0.75 6 mm² flexible with insulated ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 0.75 6 mm² flexible without ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² Stripping length 9 mm 10 mm Tightening torque 0.8 1.2 Nm 2 Nm Recommended screw driver M3.5 M4 Type Rated instantaneous Rated operational current l e short-circuit current setting l i MS116-0.16 2.00 0.16 MS116-0.25 3.13 0.25 MS116-0.4 5.00 0.40 MS116-0.63 7.88 0.63 MS116-1.0 12.50 1.0 MS116-1.6 20.00 1.6 MS116-2.5 31.25 2.5 MS116-4.0 50.00 4.0 MS116-6.3 78.75 6.3 MS116-10 150 10 MS116-12 180 12 MS116-16 240 16 MS116-20 300 20 MS116-25 375 25 MS116-32 480 32 6-2CDC131025D0202

General data Mechanical durability 100000 Electrical durability MS116 16 100000 MS116 20 50000 Duty time 100 % Operating frequency without early tripping up to 15 operations/h or 60 operations/h with Dimensions (W x H x D) see drawing on page 6 40 % duty ratio, if the motor breaking current 6 x I n and the motor starting time does not exceed 1 s Weight see table Order data on page 1 Mounting DIN-rail (EN 60715) Mounting positions Group mounting position 1-6 (optional for single mounting) on request Minimum distance to other units same type horizontal 0 mm vertical 150 mm Minimum distance to electrical conductive board horizontal, up to 400 V 0 mm horizontal, up to 690 V vertical Degree of protection housing / main circuit terminals IP20 Utilization category Maximum operating altitude permissible Maximum operating frequency > 1.5 mm 75 mm up to 2000 m 170 cycles/h Electromagnetic compatibility Electromagnetic compatibility not applicable Environmental data mbient air temperature Operation open - compensated -25... +55 C open -25... +70 C enclosed (IB132) 0... +40 C Storage -50... +80 C mbient air temperature compensation acc. to IEC/EN 60947-4-1 Resistance to vibrations acc. to IEC 60068-2-6 5g / 3... 150 Hz Resistance to shock acc. to IEC 60068-2-27 25g / 11 ms Standards / directives Standards IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC 2CDC131025D0202-7

Short-circuit breaking capacity and back-up fuses l CS Rated service short-circuit breaking capacity l CU I CC Rated ultimate short-circuit breaking capacity Prospective short-circuit current at installation location Note: Maximum rated current of the back-up fuses if I CC > I CS Type 230 V C 400 V C 440 V C 500 V C 690 V C I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am MS116-0.16 MS116-0.25 MS116-0.4 MS116-0.63 No back-up fuse required up to I CC = 30 MS116-1.0 MS116-1.6 No back-up fuse required up to I CC = 50 MS116-2.5 10 10 25 10 10 25 5 5 25 MS116-4.0 6 6 25 6 6 25 2 2 25 MS116-6.3 6 6 63 6 6 63 2 2 40 MS116-10 6 6 63 6 6 63 2 2 50 MS116-12 25 25 80 25 25 80 6 6 63 6 6 63 2 2 50 MS116-16 16 16 80 16 16 80 6 6 63 4 4 63 2 2 63 MS116-20 10 15 125 10 15 125 3 6 125 3 4 125 2 2 80 MS116-25 10 15 125 10 15 125 3 6 125 3 4 125 2 2 100 MS116-32 10 10 125 10 10 125 3 6 125 3 4 125 2 2 100 8-2CDC131025D0202

Technical data UL/CS Main circuit Maximum operational voltage 600 V Manual Motor Controller ratings see table UL 508 Manual Motor Controller on page 10 Motor ratings Horse power see table below Full load amps (FL) see table below Locked rotor amps (LR) see table below Electrical connection MS116 16 MS116 20 Connecting capacity stranded 1/2 x WG 16... 12 1/2 x WG 16... 8 flexible without ferrule 1/2 x WG 16... 12 1/2 x WG 16... 8 Stripping length 9 mm 10 mm Tightening torque 10... 12 lb-in 18 lb-in Recommended screw driver M3.5 M4 Motor rating, single phase hp Horse power FL Full load amps LR Locked rotor amps Type 120 VC 220-240 VC hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78 MS116-1.0-1 6-1.0 6.0 MS116-1.6-1.6 9.6 1/10 1.5 - MS116-2.5-2.5 15 1/6 2.2 - MS116-4.0 1/8 4 24 1/3 3.6 - MS116-6.3 1/4 6.3 37.8 1/2 4.9 - MS116-10 1/2 9.8 58.8 1-1/2 10 - MS116-12 1/2 9.8 58.8 2 12 - MS116-16 1 16 96 2 12 - MS116-20 1-1/2 20 120 3 17 92 MS116-25 2 24 144 3 17 127 MS116-32 2 24 144 5 28 162 Motor rating, three phase hp Horse power FL Full load amps LR Locked rotor amps Type 220-240 VC 440-480 VC 550-600 VC hp FL LR hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78-0.63 3.78 MS116-1.0-1.0 6.0 1.0 6.0 1/2 0.9 8 MS116-1.6-1.6 9.6 3/4 1.6 12.5 3/4 1.3 10 MS116-2.5 1/2 2.2 20 1 2.1 15 1-1/2 2.4 16 MS116-4.0 1 4.2 30 2 3.4 25 3 3.9 25.6 MS116-6.3 1-1/2 6.4 40 3 4.8 32 5 6.1 36.8 MS116-10 3 9.6 64 5 7.6 46 7-1/2 9 50.8 MS116-12 3 9.6 64 7-1/2 11 63.5 10 11 64.8 MS116-16 5 15.2 92 10 20 81 10 11 64.8 MS116-20 5 15.2 92 10 14 81 15 17 93 MS116-25 7-1/2 22 127 15 21 116 20 22 116 MS116-32 10 28 162 20 27 145 25 27 146 2CDC131025D0202-9

UL 508 Manual Motor Controller Type Maximum fuse type Maximum short-circuit current K5 o. RK5 per UL/NEC for motor disconnect 1) for group installation 480 V / 600 V 480 V 600 V 480 V 600 V MS116-0.16 100 30 5 18 5 MS116-0.25 100 30 5 18 5 MS116-0.4 100 30 5 18 5 MS116-0.63 100 30 5 18 5 MS116-1.0 100 30 5 18 5 MS116-1.6 100 30 5 18 5 MS116-2.5 100 30 5 18 5 MS116-4.0 100 18 5 18 5 MS116-6.3 100 18 5 18 5 MS116-10 100 18 5 18 5 MS116-12 100 18 5 18 5 MS116-16 100 18 5 18 5 MS116-20 100 18 5 18 5 MS116-25 100 18 5 18 5 MS116-32 100 18 5 18 5 1) Suitable as motor disconnect only when provided with padlock S1 or S3... 10-2CDC131025D0202

Contact us BB STOTZ-KONTKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the BB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB G does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB G. Brochure number 2CDC 131 025 D0202 (08.2014) Copyright 2014 BB ll rights reserved