INSTALLATION INSTRUCTIONS

Similar documents
POWERED ELECTRONIC LOCK. TECHNICAL DATA and INSTRUCTIONS XT.E01.../E21.../G01.../G21...

SPARE PARTS AND VARIOUS ACCESSORIES

QUICK UNLOCKING AND REARMING LOCKS

SECURITY LOCKS WITH ELECTRONIC LOCK MECHANISM

ELECTRONIC LOCKS AND BARS BLOCK POWERED ELECTRIC LOCKS

SPARE PARTS AND VARIOUS ACCESSORIES

The best in security is at your fingertips

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Switching DC Power Supply

SUSPENSION MODULE by

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

COOKSON OWNER'S MANUAL

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

SAFEGUARDING YOUR SECURITY EUROPROFILE CYLINDER VERTICAL RIM LOCKS

Mod: KLD6-12/35XLAS-N

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

AWZ 200. AWZ 13,8V/2A/7Ah/L

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

DOUBLE-BITTED MULTI-SYSTEM LOCKS + EURO- PROFLE CYLINDER

DOUBLE-BITTED MULTI-SYSTEM LOCKS + EURO- PROFLE CYLINDER

USE AND MAINTENANCE MANUAL. J-Giotto-Top GB-IST-JGIOT-0112

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

Powers TM Controls EA 338 Electronic Actuator

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Ex m Solenoid Operator Type 0519

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-0112

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

EStrong-series Emergency Stop

MKey9-series Safety Interlock Switch with Guard Locking

EC DECLARATION OF CONFORMITY


USB Charge Port Installation Instructions

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

PSU-S-12V/L-3A/9/FTA/PTC-TR-MC AWZ v.1.0

Installation Instructions & Users Manual

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Installing Power Components

Automatic concealed bollards 275 H600 and 275 H800 with pit

OPERATING INSTRUCTIONS

Fuse state indicator MEg72. User manual

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

GTS 15/25/40/50/60/75/90/120A

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

LESTRONIC II BATTERY CHARGER MODEL 19740

M100F Incremental Motor Actuator R81F Interface Board

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-1113

Emergency lighting units EM powerled

Uninterruptible power supply Supply MEg101.4

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Installation Instructions Central Battery Units

Model 1693, 1694 Switching DC Power Supply

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

USE AND INSTALLATION HANDBOOK

CVR-625. Compact Vibrating Rod Instruction Manual

Astor 20 Colony Counter User s Manual

Please read and understand all precautions prior to use.

Triple Output Power Supply

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

SPACESAVER EC-300 A ELECTRICS

Owner's/Installation Manual

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

GL1200T Cut & Seal. (GL1200 Seal only)

9 VOLT ALKALINE. not included

BMRX Series ROTARY LEVEL CONTROL

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

CRD610 Automatic Fitting Inserter

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

C3 Operating Instructions

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Safety switches with solenoid and separate actuator

HPSB 2512B v.1.0 HPSB 13,8V/2A/7Ah Buffer, switch mode power supply unit.

CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:

FHC-1D user manual. Features

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Installation and Maintenance Manual

Tina 4A Connection block

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

CRD600 Automatic Fitting Inserter

ISTRUCTION MANUAL Italian Movements Italian Movements

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

MODEL ELC-12/60-D BATTERY CHARGER

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

GENERALITIES TECHNICAL FEATURES

Model 1672, 1673 Triple Output Power Supply

DC Master 24/ A

Transcription:

POWERED ELECTRONIC LOCK INSTALLATION INSTRUCTIONS RECHARGEABLE F 1.0

TABLE OF CONTENTS 1 - GENERAL INSTRUCTIONS... pag. 3 1.1 - WARRANTY TERMS 1.2 - LIMITS OF LIABILITY 2 - INSTALLATION... 4 2.1 - DRILLING DIAGRAM AND DIMENSIONS 2.2 - CYLINDER FIXING 3 - ESCUTCHEONS... 6 3.1 - INTERNAL BOARD VERSION 3.2 - EXTERNAL BOARD VERSION 4 - CONNECTING REMOTE CONTROL DEVICES... 8 4.1 - EXTERNAL PERIPHERAL VOLTAGE-FREE CONTACT - INTERNAL BOARD VERSION 4.2 - EXTERNAL PERIPHERAL VOLTAGE-FREE CONTACT - EXTERNAL BOARD VERSION 4.3 - EXTERNAL PERIPHERAL MOTTURA REMOTE CONTROL - INTERNAL BOARD VERSION 4.4 - EXTERNAL PERIPHERAL MOTTURA REMOTE CONTROL - EXTERNAL BOARD VERSION 5 - CONNECTING THE POWER SUPPLY... 10 6 - ELECTRICAL WIRING... 17 6.1 - ELECTRIC WIRING - INTERNAL BOARD VERSION 6.2 - ELECTRIC WIRING - EXTERNAL BOARD VERSION 7 - AC/DC ADAPTER CONNECTION... 19 7.1 - MECHANICAL FIXING 7.2 - ELECTRICAL CONNECTION 7.3 - TECHNICAL DATA 2 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

1 - GENERAL INSTRUCTIONS Mottura Serrature di Sicurezza S.p.A. thanks you for choosing this product and reminds you : - To read all of these instructions very carefully before installing the lock or doing any maintenance work on the product. - That all assembly and connection procedures must be done in conformity to the rules of Good Practice and to current law. DO NOT install this product in rooms or atmospheres at risk of explosion or in the presence of flammable fumes/gases. - Do not install the lock on doors with risk of contact with water or atmospheric agents if not properly protected. - To switch off the power supply and disconnect all live parts before doing any installation or maintenance work on the product. Take all possible precautions to eliminate the risk of electrical shock when doing the installation or maintenance procedures described in this manual. - The installer must deliver these instructions and all of the maintenance instructions to the user. - Keep these instructions for future reference and attach the sales receipt to validate the warranty. - In case of problems contact authorized dealers only. This manual explains how to connect the lock according to a logical-functional sequence. First connect all of the selected peripherals and then the power supply. 1. Connecting the escutcheons (allow lock to be controlled on door) 2. Connecting the remote control units (allow remote control of the lock) 3. Connecting the power supplies. If you have to disconnect the wires, do the above steps in the reverse order, i.e., always disconnect the power supplies first. Mottura Serrature di Sicurezza S.p.A. may change the characteristics of the products described in these instructions at any time and without notice. 1.1 - WARRANTY TERMS This product has been inspected by Mottura Serrature di Sicurezza S.p.A. and is guaranteed to be free of all manufacturing defects for the time specified by current Italian law, starting on the date of purchase indicated on the sales receipt. The warranty is in force if the sales receipt, showing details identifying the product, is exhibited to customer service personnel. The warranty covers the replacement or repair of parts found defective at origin due to manufacturing defects. Costs of shipping to and from service centers will be paid by the customer. In case of repeated malfunctions of the same type or unrepairable defects, Mottura Serrature di Sicurezza S.p.A. may, at its own discretion, replace the complete product. The warranty on the replaced product will continue until expiration of the original warranty. If work is necessary at the customer s home, the customer will be required to pay a charge for the costs of transfer of authorized technical personnel. Transport will be at the customer s risk if the product is sent by the customer and at the authorized technician s risk if the product is picked up and transported by the technician. 1.2 - LIMITS OF LIABILITY The warranty does not cover damage due to: - negligence, carelessness or use in any manner not described in these instructions - lack of protection of the lock prior to carrying out any work operations on the door, such as drilling or welding (welds, panel holes, structure holes, etc.), which may generate waste materials that will hinder the correct operation of the lock upon entering its mechanism - maintenance performed in any manner not described in these instructions or by unauthorized personnel - use of non-original accessories/components Mottura - transport without the necessary precautions and from any circumstances that cannot be attributed to manufacturing defects. Work temperature: -10 C to +55 C. The batteries guarantee correct operation of the lock in the specified temperature range. If such temperature extremes are approached or exceeded, battery performance may decrease rapidly, with possible malfunction of the electrical part. In case of extremely low temperatures, it is advisable to power the lock from the mains by using the 230/12 V transformer. In addition, Mottura Serrature di Sicurezza S.p.A. declines all liability for any damage to persons or property deriving from failure to observe all of the precautions described herein. N.B. Mechanical lock operation is guaranteed even when the electronics of the lock has no anomaly. This excludes any electronic safety level. Mechanical keys should therefore only be used by the owner and/or by extremely trustworthy persons. 3

2 - INSTALLATION Fix the lock to the door structure by using all of the fasteners: side attachments (A), bushings (B) or mortise-type (C) (Fig. 1). In order to work correctly, the lock should be fixed in a vertical position. The lock may not work properly if installed or used in a different position. For correct operation of the lock, the spring latch must be able to protrude freely without frictioning when the door is open or closed. If necessary, drill spaces in the door structure to hold the battery pack and the box for the electronic board (supplied in the pack for the selected version) in a non-binding position defined only by the length of the wires and by internal dimensions due to door configuration (opening limiter, switchlocks, etc.). Drill the frame for the door status sensor. For these drillings, see the attached mounting diagram in Fig. 2. Place correctly the striker according to instructions TOP/BOTTOM indicated on the PCB.,Set, if necessary, the the detector contacts depth on the lock by means of the adjustment screw (Fig.2A) at a maximum distance of 4 mm from the keeper. DO NOT lubricate the contacts, periodically clean with alcohol. If you are mounting switchlocks, always provide sufficient clearance between the bar and the upper and lower tabs both when the lock is open and when it is closed, so as to prevent strain that could damage the motor. Fasten the battery pack, if required, and wire it as shown in paragraphs 3, 4, 5, 6 (diagrams Fig.3RH and Fig.3LH), (depending on door version), preparing the connections for the board holder, lock and the internal and external escutcheons using the wires supplied as standard. Protect the lock before doing any work on the door that could produce waste material (soldering, drilling of panels, drilling of structure, etc.) that might enter the lock and impair its functioning. Do not insert the batteries into the battery holder until finished fixing to avoid short circuits that may damage the system. WARNING! When the door is completely mounted and perfectly positioned, run the first checks on the lock (opening/closing) in mechanical mode to make sure there is no frictioning on the levers (bars/switchlocks) or on the key when turning. These problems could impair correct electronic operation of the lock and cause permanent malfunction. Mottura Serrature di Sicurezza S.p.A. declines all liability if this procedure is not performed and, in such case, all warranties on the product will lapse. If a mains powered connection is provided, it is advisable to use grommet 99144 (not included) between fixed upright and leaf, attaching it as shown in the detail (Fig. 3RH and Fig. 3LH) and instructions attached to the grommet pack. A A C B B A = SIDE ATTACHEMENTS B = BUSHINGS C = MORTISE- TYPE B B Variation in bolt centre distances A A SENSOR Fig.1 4 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

2.1 - DRILLING DIAGRAM (CHANGEABLE POSITIONS) AND DIMENSIONS BOARD HOLDER EXTERNAL ELECTRONIC BOARD VERSION Variation in bolt centre distances 20 TOP 43 BOTTOM DETECTOR STRIKER DOOR ELECTRIC STRIKER BATTERY HOLDER DOUBLE TUBE VERSION Fig.2A BATTERY HOLDER CASSETTE VERSION Fig.2 2.2 - CYLINDER FIXING For proper functioning of the lock, we recommend installation of a MOTTURA CHAM- PIONS double or half Europrofile cylinder (according to application) (DO NOT use cylinders with knobs). For better protection of the cylinder from the outer side of the door, we recommend the use of MOTTURA DEFEN- DER systems. For these articles (not included in the pack), please see MOTTURA catalogs. Alternatively use European cylinder with the dimension shown in the diagram. Defender 1 2 99.293/L 99.066 5

3 - ESCUTCHEONS 3.1 - INTERNAL BOARD VERSION The escutcheon is designed for installation on the door panel in a position near the two other user work zones (handle and cylinder escutcheon). When installing, use the drilling diagram shown below and remember that the connection is 1000 mm long. For installation other than as indicated, check that the length allows for such installation without hinder movement of the bars or limiter; otherwise, contact your authorized dealer. Before fixing the escutcheon to the panel (with the 2 screws equipped), position the sealing strip in its seat in the rear of the escutcheon (see detail rear view), then insert the connector securely into place. When fixing is complete, insert the metallic escutcheon cover, which is available in different finishes. The escutcheons have an IP51 protection rating. O-RING O-RING Ø40 Ø40 OUTSIDE DOOR INSIDE DOOR KEYBOARD VERSION (ART. 99.685) Protect the s against tampering. O-RING N 2 Ø2 N 2 Ø2 Cable 99.698 Ø40* N 2 Ø2 DISPLAY VERSION (ART. 99.688) Cable 99.699 O-RING Cable 99.699 Cable 99.698 Ø40* N 2 Ø2 * 40 mm diameter hole to be drilled only on the external panel. Cut a 36x20 mm opening on the plate if the external panel has thickness less than/ equal to 6 mm; otherwise, cut a 32x8 mm slot. KEYBOARD + TRANSPONDER VERSION (ART. 99.686) TRANSPONDER VERSION (ART. 99.687) The internal and external escutcheons are interchangeable. You can replace keyboard version (Art.99685) with display version (Art. 99688) and the transponder-only escutcheon (Art. 99687) with the keyboard/transponder escutcheon (Art. 99686) at any time. Always switch off the power supply before making any replacement. Remember that all of the codes and transponder keys are memorized in the lock card. 6 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

3.2 - EXTERNAL BOARD VERSION Connections for version with board external to the lock. O-RING O-RING Ø40 Ø40 INSIDE DOOR N 2 Ø2 N 2 Ø2 KEYBOARD VERSION (ART. 99.685) Cable 99.698 DISPLAY VERSION (ART. 99.688) Cable 99.700 Protect the s against tampering. Cable 99.698 Cable 99.699 Cable 99.699 O-RING O-RING OUTSIDE DOOR Ø40* N 2 Ø2 Ø40* N 2 Ø2 * 40 mm diameter hole to be drilled only on the external panel. Cut a 36x20 mm opening on the plate if the external panel has thickness less than/ equal to 6 mm; otherwise, cut a 32x8 mm slot. KEYBOARD + TRANSPONDER VERSION (ART. 99.686) TRANSPONDER VERSION (ART. 99.687) The internal and external escutcheons are interchangeable. You can replace keyboard version (Art.99685) with display version (Art. 99688) and the transponder-only escutcheon (Art. 99687) with the keyboard/transponder escutcheon (Art. 99686) at any time. Always switch off the power supply before making any replacement. Remember that all of the codes and transponder keys are memorized in the lock card. 7

4 - CONNECTING REMOTE CONTROL DEVICES 4.1 - EXTERNAL PERIPHERAL VOLTAGE-FREE CONTACT INTERNAL BOARD VERSION You can operate the lock with a Normally Open button or with a device fit with a Normally Open voltage-free contact (not supplied) to be connected to the lock by means of 99.701 (not supplied). Closing this contact for an interval from 0.5 to 2.0 seconds is equivalent to using button E on the internal escutcheon. If the remote opening button/device is located more than 4 meters away from the lock, install a relay (not supplied) between the door and the device, with the coil connected to the remote control and the Common and Normally Open contacts of the relay connected to the lock with 99.701. The has to run through a grommet (Art. 99.144 available on request). Connect 99.701 as shown on the following diagrams. 4 meters max. Cable 99.701 REMOTE CONTROL DEVICE if longer than 4 meters Cable 99.701 REMOTE CONTROL DEVICE RELAY Cable 99.701 TRANSFORMER 4.2 - EXTERNAL PERIPHERAL VOLTAGE-FREE CONTACT EXTERNAL BOARD VERSION Connections for version with board external to the lock. 4 meters max. REMOTE CONTROL DEVICE Cable 99.701 Cable 99.700 if longer than 4 meters Cable 99.701 REMOTE CONTROL DEVICE RELAY Cable 99.701 Cavo 99.700 TRANSFORMER 8 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

4.3 - EXTERNAL PERIPHERAL MOTTURA REMOTE CONTROL (99.684) INTERNAL BOARD VERSION You can remotely operate and control the lock with the REMOTE CONTROL device (code 99.684 available on request), to be connected to the lock by means of 99.702 (not supplied). Thanks to this device (which transmits an encrypted signal to the lock), any attempt to short-circuit the connection will have no effect. The has to run through a grommet (Art. 99.144 available on request) and is connected to the lock with the 6-pin connector. See the installation manual supplied with the remote control for information on its connection and use. 4 meters max. Cable 99.702 4.4 - EXTERNAL PERIPHERAL MOTTURA REMOTE CONTROL (99.684) EXTERNAL BOARD VERSION Connections for version with board external to the lock. Cable 99.700 Cable 99.700 Cable 99.702 4 meters max. 9

5 - CONNECTING THE POWER SUPPLY The XMODE lock offers a number of options based on the type of power supply and electronic board chosen for the system. TYPE OF ELECTRONIC BOARD: - Internal (board inside lock) - External (board is in a black plastic box outside the lock) POWER SUPPLY ALKALINE MAINS INTERNAL ELECTRONIC BOARD ALKALINE + MAINS by ELECTRIC STRIKER XMODE F1.0 WIRINGS ALKALINE + MAINS by GROMMET RECHAR- GEABLE + MAINS by ELECTRIC STRIKER POWER SUPPLY SYSTEM (with dedicated optional accessories): - Non-rechargeable alkaline batteries - Mains - Non-rechargeable alkaline batteries + mains - Rechargeable batteries + mains Before switching on the power supply and/or putting the batteries in their housings, make all of the connections and check that all wirings are correct. The AC/DC Adaptor (Art. 99.683) must be placed as close as possible to the door because it is always preferable to keep the 230 VAC main power s long rather than the 12 VDC lock power s in order to minimize voltage drop on the. If you have to lengthen the lock power s, never exceed 15 meters with a section of at least 1.5 mm2 (AWG15). WARNING! The electric is not provided, it must have a larger cross-section of 0.5 mm2 (AWG19) and maximum lengths 4 meters, otherwise for upper section for lengths over meters. We recommend to use coloured s RED (positive) and BLACK (negative) to distinguish the polarity. The following table shows the possible power supply combinations, specifies the wiring diagram to be used for each, and lists the codes for wirings and the components used. RECHAR- GEABLE + MAINS by GROMMET ALKALINE MAINS EXTERNAL ELECTRONIC BOARD ALKALINE + MAINS by ELECTRIC STRIKER ALKALINE + MAINS by GROMMET RECHAR- GEABLE + MAINS by ELECTRIC STRIKER BATTERY PACK Fig. A Fig. E Fig. G Fig. B Fig. F Fig. H MAINS Fig. C Fig. E Fig. G Fig. D Fig. F Fig. H RECHAR- GEABLE + MAINS by GROMMET WIRING BATTERY CHARGER Fig. G Fig. H EXTERNAL BOARD Fig. B Fig. D Fig. F Fig. H BYPASS STRIKER Fig. F -- Fig. H -- COMPONENT BATTERY CHARGER Fig. G Fig. H AC/DC ADAPTER Fig. C Fig. E Fig. G Fig. D Fig. F Fig. H STATE OF JUMPER INDIFFE- RENT OPEN CLOSE OPEN CLOSE OPEN NOTE : If you use the battery charger (art. 99 711), please note that the s have been designed to be mounted inside the door. Refer to the installation instructions provided with the article. STATE OF JUMPER Set the jumper according to the way in which it supplies power to mains and independently of the use of batteries. Lock supplied with CLOSED jumper, if the power supply is taken from the striker plate or if the lock is operated only by batteries, then nothing has to be done. If on the contrary, lock is operated directly by mains power (by 99.697 ), it is mandatory to OPEN the jumper. The jumper is located in the back of the lock below the connector of the battery protected by an adhesive label, and its state is described in detail in the wiring table. To OPEN the jumper, disconnect all power supplies and batteries, be careful not to cause a short circuit between the outer casing of the lock and the electronic board. Remove the protection and pull out the jumper using the tweezers. 1 2 WARNING! DO NOT CONNECT THE TWO CONTACTS OF THE STRIKER The connection CAN IRREVERSIBLY damage the device compromising the operation lock. 10 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

BATTERY PACK WIRING 99.703 Wired tube battery pack battery pack wire 99.704 Wired cassette battery pack CHECK JUMPER STATE Fig. A BATTERY PACK WIRING EXTERNAL BOARD 99.703 Wired tube battery pack battery pack wire 99.704 Wired cassette battery pack 99.700 Fig. B 11

WIRING MAINS POWERED 99.683 AC/DC Adapter (see chapter 7) 230VAC 12VDC Grommet 99.144 99.697 CHECK JUMPER STATE Fig. C WIRING MAINS POWERED EXTERNAL BOARD 99.683 AC/DC Adapter (see chapter 7) 99.697 230VAC 12VDC 99.700 Grommet 99.144 Fig. D 12 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

WIRING MAINS POWERED + 99.703 Wired tube battery pack battery pack wire 99.704 Wired cassette battery pack 99.683 AC/DC Adapter (see chapter 7) CHECK JUMPER STATE 99.697 230VAC 12VDC RED BLACK Grommet 99.144 WARNING! The power can be supplied to the lock or directly using the 99697 via grommet, or via striker. ONES EXCLUDES THE OTHER ONE POWER VIA GROMMET 99.697 POWER VIA STRIKER NOT provided (red/black) Fig. E 13

WIRING MAINS POWERED + EXTERNAL BOARD 99.703 Wired tube battery pack battery pack wire 99.704 Wired cassette battery pack 99.700 99.683 AC/DC Adapter (see chapter 7) BYPASS 99.715 ONLY IF POWER SOURCE FROM STRIKER 99.697 230VAC 12VDC RED BLACK Fig. F Grommet 99.144 WARNING! The power can be supplied to external board - directly using the 99697, via grommet - via striker using the BYPASS 99715. ONES EXCLUDES THE OTHER ONE POWER VIA GROMMET 99.697 POWER VIA STRIKER NOT provided (red/black) Fig. F 14 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

WIRING MAINS POWERED + RECHARGEABLE 99.703 Wired tube battery pack battery pack wire 99.704 Wired cassette battery pack 99.712 99.711 Battery charger CHECK JUMPER STATE 99.697 99.683 AC/DC Adapter (see chapter 7) RED BLACK 230VAC 12VDC Grommet 99.144 WARNING! The power can be supplied to the lock or directly using the 99697 via grommet, or via striker. ONES EXCLUDES THE OTHER ONE POWER VIA GROMMET 99.697 POWER VIA STRIKER NOT provided (red/black) Fig. G 15

WIRING MAINS POWE- RED + RECHARGEABLE EXTERNAL BOARD 99.703 Wired tube battery pack battery pack wire 99.712 99.704 Wired cassette battery pack 99.700 99.711 Battery charger BYPASS 99.715 ONLY IF POWER SOURCE FROM STRIKER 99.697 99.683 AC/DC Adapter (see chapter 7) RED BLACK Fig. F 230VAC 12VDC Grommet 99.144 WARNING! The power can be supplied to external board - directly using the 99697, via grommet - via striker using the BYPASS 99715. ONES EXCLUDES THE OTHER ONE POWER VIA GROMMET 99.697 POWER VIA STRIKER NOT provided (red/black) Fig. H 16 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

6 - ELECTRICAL WIRING 6.1 - ELECTRIC WIRING - INTERNAL BOARD VERSION Internal Escutcheon N.B. Escutcheons vary depending on the selected configuration External Escutcheon RIGHT-HAND OPENING(RH) the left-hand opening version (LH) is specular FOR SPECIFIC WIRINGS SEE PARAGRAPHS 3,4,5,6 N.B. The diagram represents a full installation where the batteries only serve in the event of a blackout. The lock can also be wired only to the MAINS POWER or exclusively by BAT- TERY power (cassette or double tube version). 99.684 Remote control EXTERNAL PERIPHERAL Voltage-free contact 99.683 AC/DC Adapter Door status sensor MAINS Battery pack cassette version Grommet Fig.3dx In the MAINS POWERED configuration, AC/DC Adapter 99.683 must be installed outside the door. N.B. Make all connections with power switched off and batteries disconnected. double tube version 17

6.2 - ELECTRIC WIRING - EXTERNAL BOARD VERSION LEFT-HAND OPENING (LH) the right-hand opening version (RH) is specular FOR SPECIFIC WIRINGS SEE PARAGRAPHS 3,4,5,6 N.B. The diagram represents a full installation where the batteries only serve in the event of a blackout. The lock can also be wired only to the MAINS POWER or exclusively by BAT- TERY power (cassette or double tube version). Board holder EXTERNAL PERIPHERAL Voltage-free contact External Escutcheon N.B. Escutcheons vary depending on the selected configuration Internal Escutcheon 99.684 Remote control Door status sensor MAINS 99.683 AC/DC Adapter cassette version Battery pack Fig.3sx Grommet double tube version In the MAINS POWERED configuration, AC/DC Adapter 99.683 must be installed outside the door. N.B. Make all connections with power switched off and batteries disconnected. 18 99293GB- XMODE F1.0 - INSTALLATION INSTRUCTIONS - REV 01

7 - AC/DC ADAPTER CONNECTION (99.683) 7.1 - MECHANICAL FIXING The AC/DC adapter transforms the 230VAC 50/60Hz home power supply into a 12 VDC isolated non-stabilized supply to power the lock. It can be fixed to the wall: the 2 slots on the bottom of the box allow it to be hooked to screws fixed to the wall (follow the drilling instructions on the bottom). As an alternative, the box can be hooked to a DIN guide (EN 60715) (not supplied) and snapped into place (black hook facing downward). To release it, pull the black hook downward with a flat-blade screwdriver. 7.2 - ELECTRICAL CONNECTION All connections must be made by trained technical personnel in conformity to electrical safety standards and according to rules of Good Practice. INPUT: Connect the 230VAC 50/60Hz home power supply to input terminals L and N, inserting a cut-out and two-way switch up-line. Connect the ground of the power supply to the input terminal with the ground symbol. OUTPUT: Connect the lock power supply (code 99.697) to the 12 VDC output terminals, taking care to respect polarity (red to positive (+), black to negative (-)) to prevent permanent damage to the system. Double output terminals are provided ONLY to power any other Mottura devices. Using these terminals for any other purpose may permanently damage the system. MAIN 230VAC PHASE NEUTRAL GROUND LOCK 12 VDC POSITIVE + NEGATIVE - 19

REPLACING THE OUTPUT FUSE: The transformer is protected in output by a fuse. An integral fuse is indicated by the MAINS/RETE LED on the front panel; if the LED is off with power switched on, the fuse is blown. Before replacing the fuse, switch off the 230 VAC mains power supply and take all possible precautions to avoid electrical shock. Remove the terminal cover from the 12 VDC OUTPUT side by inserting a small flat-blade screwdriver a few millimeters into the center housing on the cover, then gently tilt it from the other side of the box until the fastening tab is released. Remove the screwdriver and gently slide off the terminal cover with your hands. Remove the plastic cover of the fuse holder, remove and replace the fuse with one with the same rating (see technical data, paragraph 7.3). Reposition the terminal cover before switching voltage back on. 7.3 - TECHNICAL DATA INPUT POWER SUPPLY VOLTAGE / FREQUENCY 230 VAC / 50-60Hz MAX. CURRENT DRAW MAX. POWER PROTECTION RATING < 0,105 A 24 VA IP10 (with terminal covers on) WORK TEMPERATURE Min -10 C Max.+40 C ENCAPSULATED TRANSFORMER PROTECTION T 0.125 A MECHANICAL WEIGHT 0.7 Kg DIMENSIONS MATERIAL 142 x 110 x 62 mm Blend PC/ABS self-extinguishing UL94-V0 OUTPUT VOLTAGE 12 VDC non-stabilized IMPULSE ABSORPTION ( 5 sec. max) FUSE 2 A DELAYED ACTION T 3.15 A (5 x 20) mm TERMINAL BOARD RATED SECTION OF CABLES 0.5mm 2 (AWG20) to 2 mm 2 (AWG12) 99293GB - a_013658-02/2016 REV.01 www.mottura.it SAFEGUARDING YOUR SECURITY