ORPscan20 Pocket ORP Tester Instruction Manual
|
|
- Donald Washington
- 5 years ago
- Views:
Transcription
1 ORPscan20 Pocket ORP Tester Instruction Manual BANTE INSTRUMENTS CO., LTD
2 ORPscan20 Pocket ORP Tester 1 Thank you for selecting the ORPscan20 pocket ORP tester. This manual provides a step-by-step guide to help you operate the meter, please carefully read the following instructions before use. Installing the Batteries Twist the electrode collar counter clockwise, pull the BNC connector away from the tester. Insert two AAA batteries into the battery compartment, note polarity. Align the slot on connector, gently push the connector into the tester. Twist the electrode collar clockwise until it is tight. Display ORPscan20 pocket ORP tester is equipped with an easy-to-read LCD display that used to show the measured value and mode icons. The following table describes the function of each icon. INDEX: ICON MEAS CAL SETUP HOLD DESCRIPTION Indicates the tester is in the measurement mode. Indicates the tester is in the calibration mode. Indicates the tester is in the setting mode. Indicates the measuring value has been locked. When the battery is depleted, the icon will disappear.
3 ORPscan20 Pocket ORP Tester 2 Keypad The tester has a succinct membrane keypad, names and symbols describe the each function key controls. INDEX: KEY MEAS/HOLD CAL FUNCTION Switches the tester ON/OFF. Locks the measured value, press the key again to resume measuring. Exits the calibration or setting and returns to the measurement mode. Press the key to start the calibration. Press and hold the key to enter the setup menu. In the calibration mode, press the key to set the calibration value. In the setting mode, press the key to select the default option. ENTER Confirms the calibration or selected option. Connecting the ORP Electrode 1. Take out the ORP electrode from the carrying case. 2. Insert the connector into the BNC connector socket on the tester. Rotate and push the connector clockwise until it locks. After the connection is completed, DO NOT pull on the cable. Always make sure that the connector is clean and dry. Prior to Use Remove the protective cap from the bottom of the ORP electrode. Soak the electrode in 4M KCL solution for at least 15 minutes.
4 ORPscan20 Pocket ORP Tester 3 Switching the Tester On and Off Press the Meas key to switch on the tester, the display shows measured value. Press and hold the Meas key for 5 seconds, the tester will switch off. To enable the Auto-Power Off function, please refer to chapter SETUP MENU. Power On 5 sec. Power Off Setup Menu ORPscan20 pocket ORP tester contains an integrated setup menu that is used to customize the displayed option to meet measurement requirements. MENU DESCRIPTION OPTIONS DEFAULT When the option is enabled, the tester will automatically sense a stable reading and lock the measurements. When the option is enabled, the tester will automatically switch off if no key is pressed within 8 minutes. Reset the tester to factory default settings. Enable Enable Enable Setting the default option 1. Press and hold the Cal key for 3 seconds to enter the setup menu, the tester shows a menu item and default option. 2. If necessary, press the Cal key again to select the desired option. 3. Press the Enter key to confirm, the tester moves to the next menu item. 4. Repeat the steps above until the tester returns to the measurement mode. Setting is completed. Option During the setting process, press the Meas key, the tester will exit the setup menu and return to the measurement mode. The Reset function will restore the tester back to factory default settings. If enabled, all of the calibration data and selected parameters will be lost or reset, the tester must be recalibrated.
5 ORPscan20 Pocket ORP Tester 4 ORP Calibration The tester allows 1 point calibration, but calibration is not necessary unless exact readout agreement with a work standard and at a specific ORP value is needed. 1. Rinse the electrode with distilled water. Place the electrode into a known calibration solution. Stir the electrode gently until the reading stabilizes. 2. Press the Cal key, the display shows 000/CAL and waits for entering the calibration value. 3. Press the Cal key to set the value, press the Enter key to confirm. When the setting is completed, ensure the displayed value match your calibration standard (e.g., 200mV). 4. Press the Enter key, the tester begins the calibration. 5. Wait for the reading to stabilize, the display automatically shows END. Calibration is completed. After the calibration, the measurement unit mv will convert to R.mV indicating that currently displayed value is a relative mv value. If you want to resume the absolute mv measurement, please reset the tester (Refer to chapter SETUP MENU). Absolute mv Relative mv
6 ORPscan20 Pocket ORP Tester 5 ORP Measurement Rinse the ORP electrode thoroughly with distilled water. Place the electrode into the sample solution, stir the electrode gently. Record the measured value when the reading is stable. Auto-Hold ORPscan20 pocket ORP tester contains an Auto-Hold function. If enabled, the tester will automatically sense a stable reading and lock the measurements. The icon appears on the display. If disabled, press the Hold key, the meter will immediately lock the displayed value. Press the Meas key to resume measuring. Electrode Care and Maintenance Ensure that the ORP electrode is thoroughly washed with distilled water after each use. In aggressive chemicals, dirty or viscous solutions, and solutions with heavy metals or proteins, take readings quickly and rinse electrode immediately after. If you do not use the tester for long periods, store the electrode into the 4M KCL solution. Cleaning the Electrode Contamination of the sensing element often results in slow response and inaccurate readings. If necessary, clean the element by one of the following procedures. Inorganic Deposits: 1.1 Soak the ORP electrode in 0.1M HCl for 10 minutes. 1.2 Remove and rinse with distilled water, then place in alcohol for 5 minutes. 1.3 Remove and rinse again, and soak in ph4.01 buffer solution for 15 minutes. Oil and Grease Films: 2.1 Wash the electrode gently in some detergents and water. 2.2 Dip the electrode in the 4M KCL solution for at least 30 minutes. Troubleshooting LCD DISPLAY CAUSE CORRECTIVE ACTION Electrode dried out Measured value is out of range Setting value does not match the calibration solution Electrode is broken Soak the electrode in 4M KCL solution at least 20 minutes. Check the electrode whether clogged, dirty or broken. Reset the calibration value. Replace the electrode.
7 ORPscan20 Pocket ORP Tester 6 Specifications Model Range Accuracy Resolution Calibration Point ORPscan20-999~999mV ± 2mV 1mV 1 point Measurement Modes mv and Relative mv Connector BNC Operating Temperature 0~60 C, 32~140 F Relative Humidity < 80% Power Requirements 3 1.5V "G13A" batteries Dimensions 175 (L) 40 (Dia.) mm Weight 100g
8 Hazardous Substance Statement Bante Instruments is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our product in the coming years. We welcome our customer suggestions on how to speed up these efforts. Warranty The warranty period for tester is one year from the date of shipment. Above warranty does not cover the sensor and calibration solutions. Out of warranty products will be repaired on a charged basis. The warranty on your tester shall not apply to defects resulting from: Improper or inadequate maintenance by customer. Unauthorized modification or misuse. Operation outside of the environment specifications of the products. For more information, please contact the nearest authorized distributor. BANTE INSTRUMENTS CO., LTD banteinstruments@yahoo.com Phone: Website: The information in this document is subject to change without notice. Copyright Bante Instruments, All rights reserved.
PHscan30S Pocket ph Meter Instruction Manual
PHscan30S Pocket ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan30S Pocket ph Meter 1 Thank you for selecting the PHscan30S pocket ph meter. This manual provides a step-by-step guide to help
More informationPHscan10S Pocket ph Tester Instruction Manual
PHscan10S Pocket ph Tester Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan10S Pocket ph Tester 1 Thank you for selecting the PHscan10S pocket ph tester. This manual provides a step-by-step guide to
More informationECscan20 Pocket Conductivity Tester Instruction Manual
ECscan20 Pocket Conductivity Tester Instruction Manual BANTE INSTRUMENTS CO., LTD ECscan20 Pocket Conductivity Tester 1 Thank you for selecting the ECscan20 pocket conductivity tester. This manual provides
More informationTDSscan10M Pocket TDS Tester Instruction Manual
TDSscan10M Pocket TDS Tester Instruction Manual BANTE INSTRUMENTS CO., LTD TDSscan10M Pocket TDS Tester 1 Thank you for selecting the TDSscan10M pocket TDS tester. This manual provides a step-by-step guide
More informationECscan30 Pocket Conductivity/TDS Tester Instruction Manual
ECscan30 Pocket Conductivity/TDS Tester Instruction Manual BANTE INSTRUMENTS CO., LTD ECscan30 Pocket Conductivity/TDS Tester 1 Thank you for selecting the ECscan30 pocket conductivity tester. This manual
More informationECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED
ECscan10H Pocket Conductivity Tester Instruction Manual BANTE INSTRUMENTS LIMITED ECscan10H Pocket Conductivity Tester 1 Introduction Thank you for selecting the ECscan10H pocket conductivity tester. This
More informationBante220 Portable ph Meter Instruction Manual
Bante220 Portable ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante220 Portable ph Meter 1 Introduction Thank you for selecting the Bante220 portable ph meter. This manual provides a step-by-step
More informationECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual
ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual BANTE INSTRUMENTS LIMITED Technology to create the future... ECSCAN40 POCKET CONDUCTIVITY/TDS/SALINITY TESTER 1 Introduction Thank you
More informationOperation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331
Operation Manual MODEL EC331 Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331 CONTENTS INITIAL INSPECTION AND ASSEMBLY...2 VISIONPLUS EC331 OVERVIEW...2 A. Meter Description...2
More informationSalt 1 Pocket Salinity Tester Instruction Manual
Salt 1 Pocket Salinity Tester Instruction Manual OAKTON INSTRUMENTS www.4oakton.com v1.2 Salt 1 Pocket Salinity Tester Instruction Manual 1. Battery Installation Please install batteries according to the
More informationEC20 Pocket Conductivity Tester Instruction Manual
EC20 Pocket Conductivity Tester Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com EC20 Pocket Conductivity Tester Instruction Manual 1. Battery Installation Please install batteries according
More informationPH20 Value ph Tester Instruction Manual
PH20 Value ph Tester Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com v 3.3 1 1. Battery Installation Please install batteries according to the following steps. *Please note the correct direction
More informationEC1 Pocket Conductivity Tester Instruction Manual
EC1 Pocket Conductivity Tester Instruction Manual OAKTON INSTRUMENTS www.4oakton.com v2.2 EC1 Pocket Conductivity Tester Instruction Manual 1. Battery Installation Please install batteries according to
More informationTRACER. POCKETESTER ä ORP CODE 1742
TRACER POCKETESTER ä ORP CODE 1742 TRACER ORP POCKETESTER TM CODE 1742 Table of Contents Introduction... 4 Specifications... 4 Contents... 4 Parts & Accessories... 4 Meter Description Front Panel Description...
More informationPH60 Series Premium ph Testers
PH60 Series Premium ph Testers Instruction Manual PH60 ph Tester PH60S Spear ph Tester PH60F Flat ph Tester APERA INSTRUMENTS (Europe) GmbH www.aperainst.de v5.6 Thank you for purchasing the Apera Instruments
More informationTracer ORP PockeTester TM Code 1742
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Tracer ORP PockeTester TM Code 1742 Water Testing Leader Since 1919! TRACER ORP
More informationHI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL
HI99181 Portable Waterproof Skin ph Meter INSTRUCTION MANUAL Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this meter. This
More informationSoilStik ph Meter PRODUCT MANUAL. Item # 2105
SoilStik ph Meter PRODUCT MANUAL Item # 2105 Contents General Overview...3 LCD Display...4 LCD Display Messages...5 Meter Components...6 Calibration...7 Changing the Temperature Units...8 Taking Liquid/Soil
More informationPC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4
PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com V6.4 Thank you for purchasing Apera Instruments PC60 Premium Multi-Parameter Tester.
More informationUSER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY
WARRANTY USER S GUIDE ONE YEAR LIMITED WARRANTY The PH-200, manufactured by HM Digital, Inc. ("the Company") is warranted to the purchaser against defective materials and workmanship for one (1) year from
More informationLarge Display ph Pens , , Instruction Manual
Large Display ph Pens 850050, 850051, 850052 Instruction Manual Large Display ph Pens - 850050, 850051, 850052 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of
More informationSTARTER 2000 Bench ph Meter Instruction Manual
STARTER 2000 Bench ph Meter Instruction Manual Table of Contents 1 Introduction... 2 1.1 Safety measures... 2 1.2 Display and controls... 3 2 Installation... 5 2.1 Package contents... 5 2.2 Installing
More informationCare and use guide. Contents. page
Care and use guide Contents page Features Bluelab ph Meter Introduction Preparing for use Calibration 3 Measuring the ph value 5 Battery replacement 5 Cleaning and maintenance 6 Storing the Bluelab ph
More informationCOM-100 EC / TDS / TEMPERATURE METER
USER S GUIDE COM-100 EC / TDS / TEMPERATURE METER WARRANTY ONE YEAR LIMITED WARRANTY This HM Digital, Inc. ("the Company") product ( COM-100 ) is warranted to the purchaser against defective materials
More informationInstruction Manual PORTABLE ph METER D-71
Preface Instruction Manual PORTABLE ph METER D-71 Part names and basic operation Measurement Usinig various functions Maintenance How to resolve errors or troubles Appendix Preface This manual describes
More information8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5
\ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole
More informationMODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE
MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE 1. 2. 3. 4. Connect probe to meter. Put probe in first calibrating buffer. Press ON/OFF to turn on meter. If necessary,
More informationSERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)
SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D ST400D Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D
More informationUser Manual Pocket Pro, Pro + ph
User Manual Pocket Pro, Pro + ph DOC022.52.80394 1 Specifications Specification Dimensions (W x D x H) Enclosure rating Weight Specifications are subject to change without notice. Details 37 x 30 x 170
More informationOPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S
OPERATION MANUAL PEN TYPE PH METER DESIGN PATENTED: US D453.905S Model: 8690 INTRODUTION ongratulations on your purchase of the unique shape of ph pen model 8690, the meter features dual display ph with
More informationCare and use guide. Contents. page
Care and use guide Contents page Features Bluelab ph Probe Preparing for use 3 Important Bluelab ph Probe care 3 Calibration 4 Cleaning the ph probe 5 Storing the ph probe 5 Hydrating the ph probe 6 Technical
More informationModel P772 Conductivity Meter. User Manual
Model P772 Conductivity Meter User Manual 1 Table of Contents 1 INTRODUCTION... 1 2 SAFETY SUMMARY... 2 3 COMPLIANCE STATEMENTS... 2 4 PRODUCT CONTENTS AND INSPECTION... 3 5 DEVICE DESCRIPTION... 4 6 OPERATING
More informationWalkLAB Digital Dissolved Oxygen meter HD9030
7,0,7,0,1,6,1,6,5,2,5,2,3,4,3,4 WalkLAB Digital Dissolved Oxygen meter HD9030 Operation Manual 0 INTRODUCTION Your purchase of this WalkLAB Digital Dissolved Oxygen meter marks a step forward for you into
More informationIAQ-CALC INDOOR AIR QUALITY METER MODEL 7515
IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515 OPERATION AND SERVICE MANUAL P/N 1980571, REVISION D FEBRUARY 2016 Copyright TSI Incorporated / May 2007-2016 / All rights reserved. Address TSI Incorporated
More informationInstruction Manual. PHscan30 Pocket ph Tester
Hazardus Substance Statement Bante is cmmitted t the reductin and eventual eliminatin f all hazardus substances in bth the manufacturing prcess and finished prducts we supply. We have an active manufacturing
More informationtesto 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual
testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung de Instruction Manual en 18 General Information General Information Please read this document through carefully and familiarise yourself
More informationHI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI
Instruction Manual HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI 931500 HI931501-HI 932500 Panel - Mounted ORP - ph Indicators and Controllers ORP HI 8720E mv DOSAGE SLOPE OXID. REDUC. MEA SURE AL COARSE
More informationSERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER
More informationExterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation
Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview
More informationIndoor Air Quality Meter
Indoor Air Quality Indoor Air Quality Meter Alnor Model CF910 AIRFLOW TM Model IAQ910 Operation and Service Manual Copyright TSI Incorporated / 2007-2008 / All rights reserved. Address TSI Incorporated
More informationDMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DMG100 Digital Micron Gauge Parts Diagram 2 LCD Display Item A B C Main Numeric
More informationDMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free
DMG200 Digital Micron Gauge 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Parts Diagram 2 LCD Display Item A B C Main Numeric
More informationRally computer 3 Rally computer 3.GPS *
Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to
More informationIAQ-CALC TM Indoor Air Quality Meter
ENERGY AND COMFORT Indoor Air Quality IAQ-CALC TM Indoor Air Quality Meter Model 7515 Operation and Service Manual Copyright TSI Incorporated / May 2007 / All rights reserved. Address TSI Incorporated
More informationVisit us at
Instruction Manual testo 205 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information
More informationValor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur
Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS
More informationIAQ-CALC TM Indoor Air Quality Meter
ENERGY AND COMFORT Indoor Air Quality IAQ-CALC TM Indoor Air Quality Meter Model 7515 Operation and Service Manual Copyright TSI Incorporated / May 2007 / All rights reserved. LIMITATION OF WARRANTY AND
More informationVisit us at
Instruction Manual testo 206 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information
More informationDawson DSM170 Multi-Function Moisture Meter User s Manual
Dawson DSM170 Multi-Function Moisture Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 3 Safety Information... 4 INTRODUCTION...
More informationFuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2
Fuel Level FL1 Revision#2.0, 28/11/2014 For firmware version 1.2 FL1 - User s manual Page intentionally left blank SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION OPERATING INSTRUCTIONS INSTRUMENT
More informationMarin Control Digital
Operation Manual Marin Control Digital Digital Meter for the measurement of Temperature, salinity and specific gravity in saltwater aquariums. Short instructions: ON OFF : Is used to turn the power on
More informationHanTron Model HT-3P. Manual. Installation Maintenance Repair Manual
Manual HanTron Model HT-3P Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com
More informationInstruction Manual. ph Meter D-51
Instruction Manual ph Meter D-51 Preface Thank you for purchasing the D-51 ph meter. This meter is designed with a compact body that can be held in one hand and features a water-resistant construction
More informationDigital Formaldehyde Meter
USER GUIDE Digital Formaldehyde Meter Model FM100 Introduction EXTECH INSTRUMENTS Thank you for selecting the Extech Instruments Model FM100. The FM100 measures Formaldehyde CH 2 O (HCHO) concentration,
More informationUser's Guide. CO 2 Meter. Model CO250
User's Guide CO 2 Meter Model CO250 Introduction Congratulations on your purchase of this Model CO250 Meter. This meter measures CO2 (Carbon Dioxide) levels, air temp., dew point, wet bulb temperature
More informationOPERATING INSTRUCTIONS
CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7
More informationInstruction Manual Portamess 911 Cond
Instruction Manual Portamess 911 Cond ProMinent Dosiertechnik GmbH D-69123 Heidelberg Germany ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 D-69123 Heidelberg Postfach 10 17 60 D-69007 Heidelberg
More informationUser Manual dpette+ Electronic Pipette 2016-ver.1
User Manual dpette+ Electronic Pipette 2016-ver.1 CONTENTS 1. Product Overview...- 1-2. Parts Description...- 3-3. Display... - 5-4. Operation...- 6-5. dpette+ setup... - 14-6. Storage... - 18-7. Care
More informationCare and use guide Guía de uso y cuidado Guide d utilisation et d entretien.
Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien www.getbluelab.com Features 1.0 To operate English Backlit LCD display Hold reading function Fully guaranteed for 1 year Low
More informationCIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)
CIRCUIT-TEST Switching Mode Power Supply with Remote Sensing PSC-9800 0-16V 5A / 0-27V 3A / 0-36V 2.2A (80W) OPERATION MANUAL 1 2 PSC-9800 08R14 Contents Safety Precautions...page 4 Introduction... 5 Controls
More informationTable of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...
Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2
More informationOPERATING INSTRUCTION MANUAL
OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:
More informationAIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410
AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410 OPERATION AND SERVICE MANUAL P/N 1980575, REV F FEBRUARY 2016 Copyright TSI Incorporated / 2007-2016 / All rights reserved. Address
More informationUSER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at
USER MANUAL White LED Light Meter Model LT40 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech LT40 LED Light Meter that measures
More informationTABLE OF CONTENTS. Firmware Version
TABLE OF CONTENTS Firmware Version...1 Environmental Conditions...1 Electrical Specifications...1 Warnings...2 Section A: Programming the Controller...3 A 1: The Program Menu...3 A 1.1: Entering the Program
More informationDAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM
Digital Air Flow Meter INSTRUCTION MANUAL ENGLISH DAFM4 DAFM4 VOL CFM LW MODE HOLD START STOP EXIT LW-D-AREA MAX / MIN [HOLD TO EXIT AVG AVG MODE] ON / OFF (SET) 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com
More informationDOUBLE WAYS THERMOCOUPLE METER. Users Manual
DOUBLE WAYS THERMOCOUPLE METER Users Manual .Introduction Thank you for purchasing the double ways thermocouple meter from us. Please take a few minutes to browse through this user manual before you begin
More informationIntelligent torque meter tester
Intelligent torque meter tester Before using this product, please read the instructions carefully, which will help improve the efficiency of your use of this product Contents 一 About HP Series Torque Meter...2
More informationOperator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)
Operator's Manual Rev: ev: D08 Operator's Manual TABLE OF CONTENTS Firmware Version...1 Environmental Conditions...2 Electrical Specifications...2 Warnings...3 Section A: Programming the Controller...4
More informationMPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS
1. SAFETY The MPT-250B Wire Crimp Pull Tester is a force measurement device, and as such should be operated with due caution. Operators should wear safety glasses for eye protection because the crimp under
More informationADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM
-im -issue2-2017 INSTRUCTION MANUAL DIGITAL DIESEL METER INSTRUCTION MANUAL DIGITAL DIESEL METER INTRODUCTION Thank you for purchasing a Macnaught Electronic Turbine Meter The Macnaught digital turbine
More informationBreath Alcohol Tester
Breath Alcohol Tester Professional Fuel cell sensor Personal & professional use alcohol tester AF-50 Instruction Manual 50 sets of data memory Professional Fuel Cell Sensor Law enforcement grade accuracy
More informationMoistureMatch A next generation grain tester
MoistureMatch A next generation grain tester A next generation moisture tester incorporating new and unique technology. Finally, a portable tester that will more accurately match and track with the commercial
More informationVELOCICALC Air Velocity Meter
ENERGY AND COMFORT Ventilation Testing VELOCICALC Air Velocity Meter Model 9515 Operation and Service Manual Copyright TSI Incorporated / May 2007 / All rights reserved. Address TSI Incorporated / 500
More information4&5 RANGE CONDUCTIVITY METERS Operation Instructions
4&5 RANGE CONDUCTIVITY METERS Operation Instructions User Manual for Models EP EP10 6115 Corte del Cedro Carlsbad, CA 92009-1516 USA Tel 760-438-2021 Fax 800-869-7668 / 760-931-9189 www.myronl.com ph/conductivity
More informationMPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS
MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS DATASHEET 1. SAFETY The MPT-200A Wire Crimp Pull Tester is a force measurement device, and as such should be operated with due caution. Operator should
More informationINTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect
INTRODUCTION Congratulations on your purchase of this digital pen type CO meter. Please read the manual completely before using the meter. Features: Adjustable CO warning level Dual and digital display
More informationOPERATION MANUAL. THE JENCO MODEL 3671 ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS
OPERATION MANUAL THE JENCO MODEL 3671 ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS 1 GENERAL INTRODUCTION The model 3671 is an all solid state designed for ph/orp measurement
More information1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2
1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2 THIS EQUIPMENT CHAPTER SHOULD BE INSERTED IN THE EQUIPMENT MANUAL MANUFACTURED FOR McDONALD S BY PERFECTION EQUIPMENT, INC. 4259 LEE AVENUE GURNEE, ILLINOIS
More informationGENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS
GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Temperature Sensor: WQ101 ph Sensor: WQ201 Conductivity Sensor: WQ301
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationManual KREBS Viscometer PCE-RVI 5
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business
More informationINSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING
DIGITAL THERMOMETERS INSTRUCTION MANUAL ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and a full understanding of its benefits please read this manual
More informationVariable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A
Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE
More informationBreath Alcohol Tester
Breath Alcohol Tester Advanced fuel cell sensor Personal & professional use alcohol tester DA-8000 Instruction Manual DA-8000 Fuel cell ( Electrochemical) accuracy 4-digit LCD display with a backlit User
More informationMDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL
For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL Blank page Contents Caution... 4 Capabilities... 4 Display and Keypad... 4 Preparations Before the Test... 6 Connecting
More informationAdam Equipment CPW COMPACT SCALE
Adam Equipment CPW COMPACT SCALE ADAM EQUIPMENT CO. LTD. pn. 3935 Rev. D, November 2002 INTRODUCTION The CPW Compact Scales are available in 4 models, with capacities from 25kg to 150kg. The scales are
More informationT R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L
T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics Static Field Meter & Ionizer Verification Unit Model EFM115
More informationSingle and 8-channel Electronic Pipettes. Operation Manual Version: 2.9
Single and 8-channel Electronic Pipettes Operation Manual Version: 2.9 Table of Contents 1. Safety Precautions...1 1.1. Operation Safety Precautions...1 1.2. Battery Safety...1 2. General Description...3
More informationAll other marks are trademarks or registered trademarks of their respective holders.
Trademarks FOXWELL is trademark of Shenzhen Foxwell Technology Co., Ltd. All other marks are trademarks or registered trademarks of their respective holders. Copyright Information 2015 Shenzhen Foxwell
More informationSPC Series. Digital Scale. Operation Manual
SPC Series Digital Scale Operation Manual Revision 1.0 August 17, 2000 ! WARNING Use only the AC adapter which comes with the scale. Other adapters may cause damage. Internal service to this product should
More informationWheel Products. WP8300 Operators Manual Rev: 910
Wheel Products by WP8300 Operators Manual Rev: 910 Table of Contents Warranty Page 1 1. General Page 2 General Safety Regulations Page 2 Field of Application Page 2 Overall Dimensions Page 2 Technical
More informationBRAKE TESTER DECELEROMETER
OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch
More informationIntelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter
Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Part #: 9047 Table of Contents: Table of Contents 2 Intelli-Feed TM User Interface 3 Equipment Diagnostic Indicators
More informationEM20 Digital Anemometer User Manual
EM20 Digital Anemometer User Manual -1- Introduction EM20 Digital Air Flow anemometer is designed to measure Temperature and Air Flow, simultaneously. It is normally used to measure the temperature and
More informationPowerView PV380-R2 Mechanical Configuration
PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive
More informationModel 8345/8346/8347/8347A VELOCICALC Air Velocity Meters
Ventilation Testing/Balancing Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters Operation and Service Manual 1980277, Revision E November 2002 Model 8345/8346/8347/8347A VELOCICALC Air Velocity
More informationPN# A,13-316A,13-317A, , , & TireGard
PN# 13-315A,13-316A,13-317A, 13-325, 13-326, & 13-327 TireGard Wireless Tire Pressure Monitoring System Table of Contents Precautions 2 TireGard Features and Benefits 2 Controls 3 LCD Receiver/Monitor
More informationInstruction Manual for Globe Price Computing Scale Models GS30 and GS30T
Model GS30 Model #: Serial #: Model GS30T NTEP Approved Meets NIST Handbook 44 Criteria Legal for Trade Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T For Service on Your Scale:
More information