Introduction to Condition-Based Maintenance Best Practices

Size: px
Start display at page:

Download "Introduction to Condition-Based Maintenance Best Practices"

Transcription

1 Introduction to Condition-Based Maintenance Best Practices

2 Maintenance Strategy Breakdown Maintenance Preventive Maintenance (Time Base) Predictive Maintenance Proactive Maintenance

3 Rationalizing Spending Time and Money on Machine that are not broken

4 Modern Maintenance Technologies CONDITION-BASED MAINTENANCE Proactive Maintenance Root Causes Contaminant Monitoring Balancing and alignment tools Viscosity and AN Monitoring Fault-Free Machine Life Extension Predictive Maintenance Failure Symptoms and Faults Wear debris analysis, Vibration Analysis, Thermography, Motor Current Analysis Early detection of faults and failure

5 Benefits of Precision Maintenance

6 Reliability Circle Lifetime Reliability

7 Are you pulling your weeds out by the root?

8 Condition Monitoring Domains in Start Failure the PF interval curve Structure Borne Ultrasound Vibration Oil analysis Infrared Audible noise P P1 P2 P3 P4 Contact heat P5 Proactive Domain Predictive Domain Fault Domain P6 F

9 CBM Technology for Mechanical Equipment Ultrasound Vibration Infrared Thermography Oil Analysis

10 Condition Monitoring- Airborne Ultrasound Technology

11 Which type of ultrasound? PULSE ECHO Medical applications Thickness gauge Flaw detection in solids ULTRASOUND DIVISIONS POWER Cleaning Welding and cutting AIRBORNE AIR & STRUCTURE BORNE STRUCTURE BORNE

12 Why Ultrasound? Sound definition: Vibrations transmitted through an elastic solid, a liquid or gas, with frequencies in the approximate range of 20 to 20,000 hertz, able to be perceived by humans Sound (Audio Sound) is not directional and penetrates solid materials, making it difficult to locate. Ultrasound is defined from 20kHz to 100kHz Advantages are: Very directional Reflects on solid materials and does not penetrate Reduces in strength, making source locating easy We can use the information for condition evaluation Two ways to detect Ultrasound with our instruments: Airborne medium Structure borne medium

13 Typical application areas Leak detection Pressure or vacuum, any type of gas Heat exchangers Tanks and boilers Window seal inspections Valve inspection Valve leak detection Steam trap inspection Mechanical inspection Condition monitoring of bearings Condition based lubrication Pumps for cavitations Conveyor belt systems Electrical inspection Discharge testing on: Switchgears Power lines & isolators Transformers Circuit breakers (Tracking, Arcing, Corona & mechanical looseness) Specialty solutions for: Automotive WNWL Aircraft inspections Marine hatch testing

14 Electrical Inspection There are situations IR is difficult to use for getting a visual line For Ultrasound all we need is an open air connection Example enclosed transformer: Early stages of tracking, evolving into arcing.into catastrophic failure!

15 Economics: leaks cost money March 2012 Air Leaks Repaired Argon Leaks Repaired Helium Leaks Repaired Hydrogen Leaks Repaired Other Leaks Repaired Cost Avoidance CFM Cost CFM Cost CFM Cost CFM Cost CFM Cost Identified Repaired % Complete 0.0 $ $ $ $ $0.00 $12, $0.00 0% Record Number Group Name Location Name Type of Gas Pressure at Leak db Reading Problem Description Repaired (Y/N) Work Order Schedule # Identified Leaks Cost Avoidance Size of Leak (CFM) 1 fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air air leak N $1, fm5 Air airleak N $1, fm5 Air air leak N $1, fm5 Air air keak N $ Energy Avoidance (kwh)

16 Condition Monitoring Vibration Analysis

17 What does it mean.? How do you know when to take action? Standards are available. SPECTRA PRO removes the guesswork.

18 Vibration analysis on AHU Fan Bearing: Detect Early Bearing Fault Measuring date BC Alarm status Remarks 1 Tuesday, December 14, :28 AM 3.66 Ok Bearing Fault Detect 2 Wednesday, January 19, :00 AM 4.60 Warning Bearing Change Recommended 3 Thursday, February 17, :42 PM 0.39 Ok Bearing Replaced SPECTRA REPORT 1 HV Air Handling Units\63001\Motor \DE Measuring date :Thursday, February 17, :42 Total value = mm/s RMS BC = 0.39 Shaft Speed=24.73 Hz

19 Condition Monitoring Thermographic Analysis

20 PUMPS ELECTRIC MOTORS CONDENSERS DIESEL GENERATORS Heavy EQUIPMENT/CRAN E CIRCUIT BREAKERS VALVES HEAT EXCHANGERS ELECTRICAL SYSTEM TRANSFORMER TANKS,PIPINGS Techniques and Applications TECHNOLOGIES APPLICATIONS VIBRATION MONITORING ANALYSIS X X X X LUBRICANT, FUEL ANALYSIS X X X X X BEARING TEMPERATURE ANALYSIS X X X X WEAR PARTICLE ANALYSIS X X X X PERFORMANCE MONITORING X X X X X X ULTRA SONIC NOISE DETECTION X X X X X X X X ULTRASONIC FLOW X X X X INFRARED THERMOGRAPHY X X X X X X X X X X X NON DESTRUCTIVE TESTING(THICKNESS) X X X VISUAL INSPECTION X X X X X X X X X X X INSULATION RESISTANCE X X X X X MOTOR CURRENT SIGNATURE ANALYSIS X MOTOR CIRCUIT ANALYSIS X X X

21 Reliability Circle Lifetime Reliability

Ultrasound, 1 st line of defense

Ultrasound, 1 st line of defense Ultrasound, 1 st line of defense Frank Ragwitz UE Systems Germany / Austria / Swiss Today s Topics Intro to UE Systems Who we are and what we do Ultrasound technology How the technology works for maintenance

More information

Practical Thermography for Mechanical Applications Pub ITC 110 H Infrared Training Center

Practical Thermography for Mechanical Applications Pub ITC 110 H Infrared Training Center Practical Thermography for Mechanical Applications 2010-05-27 Pub ITC 110 H - 2010 Infrared Training Center 1 2010-05-27 Pub ITC 110 H - 2010 Infrared Training Center 2 Lesson Objectives Learn basics of

More information

Training Courses Information

Training Courses Information Training Courses Information Health & Condition Monitoring Center Sustainable Manufacturing Systems Laboratory Iran University of Science & Technology Condition Monitoring, Maintenance & Reliability (Overview)

More information

Artesis MCM Case Studies. March 2011

Artesis MCM Case Studies. March 2011 Artesis MCM Case Studies March 2011 Case 1 Automotive Company: Automobile Manufacturer A Equipment: Pump Stator Isolation Breakdown Decreasing current unbalance level Case 1 Automotive Company: Automobile

More information

Health Based Asset Management. rjd

Health Based Asset Management. rjd Health Based Asset Management 1 Health Care Proactive and Reactive Approaches Physical Routine Screenings Symptoms Targeted Diagnostics Emergency Targeted Diagnostics 2 What is the health of the assets?

More information

Performance Service Centres. ABB Performance Services. Power and productivity for a better world TM

Performance Service Centres. ABB Performance Services. Power and productivity for a better world TM Performance Service Centres ABB Performance Services Power and productivity for a better world TM The ABB difference ABB, a global leader in power and automation technologies, has five Performance Service

More information

PM/ECCM Course Description and Outline

PM/ECCM Course Description and Outline PM/ECCM Course Description and Outline Preventive Maintenance/Essential Care and Condition Monitoring is one of the cornerstones in a world-class reliability process. Condition monitoring will provide

More information

Prevention vs. Reaction The Importance of Asset Integrity

Prevention vs. Reaction The Importance of Asset Integrity Prevention vs. Reaction The Importance of Asset Integrity How Your Assets Typically Age Inspections Potential Failure Condition Functional Failure Time P-F Interval Why is Asset Integrity so Important?

More information

High Efficiency Bypass Oil Filtration Systems for your Engine and Hydraulic Oil. Kevin Kroger (PuraDYN Filter Yechnologies MDEC 2007.

High Efficiency Bypass Oil Filtration Systems for your Engine and Hydraulic Oil. Kevin Kroger (PuraDYN Filter Yechnologies MDEC 2007. High Efficiency Bypass Oil Filtration Systems for your Engine and Hydraulic Oil Kevin Kroger (PuraDYN Filter Yechnologies MDEC 2007 The Journey to CBM Reactive Planned/ Scheduled Condition Based Maintenance

More information

HIGH VOLTAGE POWER SUPPLY DESIGN AND MANUFACTURING PRACTICES

HIGH VOLTAGE POWER SUPPLY DESIGN AND MANUFACTURING PRACTICES PAGE 1 OF 5 PREFERRED RELIABILITY PRACTICES Practice: Thoroughly test high voltage power supply packaging on flight configured engineering models, in a simulated space flight environment, to evaluate corona

More information

Steve Schouten. Donna Densmore

Steve Schouten. Donna Densmore March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation

More information

Advanced Maintenance Technologies

Advanced Maintenance Technologies Advanced Maintenance Technologies Vibration Analysis Consultants Ray W. Wonderly Certified Vibration Specialist Services: Vibration Analysis Consulting Laser Alignment Services Predictive/Planned Maintenance

More information

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY PART B-04 TITLE: DISTRIBUTION SUBSTATIONS SPECIFICATION NO: B-04 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 2 YEAR PERIOD) AMENDMENTS/REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** USACE / NAVFAC / AFCEC / NASA UFGS-01 86 26.07 40 (February 2018) Change 1-02/15 ----------------------------------- Preparing

More information

Chapter 15. Sound Longitudinal Wave Audibility Frequency Reflection of Sound Speed of Sound Characteristics of Sound

Chapter 15. Sound Longitudinal Wave Audibility Frequency Reflection of Sound Speed of Sound Characteristics of Sound Chapter 15 Sound Longitudinal Wave Audibility Frequency Reflection of Sound Speed of Sound Characteristics of Sound Sound (Lectures) Sound as a Longitudinal Wave Audibility Frequency The Human Ear Ultrasound

More information

Condition Monitoring of Electrical Machines ABB MACHsense Solution

Condition Monitoring of Electrical Machines ABB MACHsense Solution Condition Monitoring of Electrical Machines ABB MACHsense Solution Overview Typical failures in motor Traditional condition monitoring methods Shortfall Solutions ABB MACHsense service July 26, 2012 Slide

More information

Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2)

Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2) Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., ABB lead the intelligent revolution Intelligent technology (Part 2) Slide 1 Intelligent Monitor and Diagnosis The Expert System for Switchgear Slide

More information

BAS Construction Checklist

BAS Construction Checklist BAS Construction Checklist Project: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist items

More information

Variable Frequency Drives

Variable Frequency Drives We Make Energy Engaging Variable Frequency Drives Questline Academy Meet Your Panelist Mike Carter questline.com 2 Contents Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality

More information

Multi-Technology Approach to Motor Management. Technology Approach to Motor Management

Multi-Technology Approach to Motor Management. Technology Approach to Motor Management MultiTechnology Approach to Motor Management Dr. Howard W. Penrose, Ph.D. General Manager, ATEST Pro A Division of BJM Corp Old Saybrook,, CT 06475 In this presentation, we shall cover how to create success

More information

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required! DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!

More information

EXKOP MINI + QV II Quench Valve. Explosion Isolation System

EXKOP MINI + QV II Quench Valve. Explosion Isolation System EXKOP MINI + QV II Quench Valve Explosion Isolation System page 1 of 25 Table of contents 1. Operating and safety instructions 3 1.1 Safety instructions 3 1.2 Application limitation 3 2. Description 4

More information

Centro América Application of EMI Diagnostics to Diesel Generators

Centro América Application of EMI Diagnostics to Diesel Generators Application of EMI Diagnostics to Diesel Generators CATEGORIAS *Experiencias con características de lotes de combustibles * Control de eficiencia de motores * Aliados clave para operadores de motores *

More information

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure

More information

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT SWITCHCRAFT Switchcraft Europe GmbH Switchgear Product Overview igis Gas Insulated Switchgear isis Solid Insulated Switchgear icb - Vacuum Circuit Breaker iair - Air insulated switchgear panel Switchcraft

More information

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1 BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for

More information

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Straße 2 D-06112 Halle/Saale Tel: ++49-(0)345-13317-0 Fax:++49-(0)345-13317-99 http://www.sonotec.de e-mail: SONOTEC@sonotec.de Ultrasonic Leak Detector

More information

Improving predictive maintenance with oil condition monitoring.

Improving predictive maintenance with oil condition monitoring. Improving predictive maintenance with oil condition monitoring. Contents 1. Introduction 2. The Big Five 3. Pros and cons 4. The perfect match? 5. Two is better than one 6. Gearboxes, for example 7. What

More information

Leak Prevention Building Tighter Systems with Enhanced Leak Detection. Service Provided by CGRS, Inc.

Leak Prevention Building Tighter Systems with Enhanced Leak Detection. Service Provided by CGRS, Inc. Leak Prevention Building Tighter Systems with Enhanced Leak Detection Service Provided by CGRS, Inc. Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by

More information

V. Design, Application, Maintenance & Operation Technical Requirements

V. Design, Application, Maintenance & Operation Technical Requirements V. Design, Application, Maintenance & Operation Technical Requirements V.L Line & Substation Operation and Maintenance 1.0 General Requirements 1.1 Each facility owner shall have an established and documented

More information

ULTRASOUND IS MORE THAN A LEAK DETECTOR. By Deborah Hays Dmax Ltd.

ULTRASOUND IS MORE THAN A LEAK DETECTOR. By Deborah Hays Dmax Ltd. ULTRASOUND IS MORE THAN A LEAK DETECTOR By Deborah Hays Dmax Ltd. Dmax Ltd. We machine and assemble the Duramax Diesel Engine for General Motors Heavy Duty Trucks. Machining Side of the Plant Cylinder

More information

Marine Industry Offshore Rail. Worldwide repair and services on generators, electromotors and transformers. We take care of it

Marine Industry Offshore Rail. Worldwide repair and services on generators, electromotors and transformers. We take care of it Marine Industry Offshore Rail Worldwide repair and services on generators, electromotors and transformers We take care of it Bakker Repair + Services, your partner for worldwide repair and services Bakker

More information

Marine Industry Offshore Rail. Worldwide repair and service for electrical rotating equipment. We take care of it.

Marine Industry Offshore Rail. Worldwide repair and service for electrical rotating equipment. We take care of it. Marine Industry Offshore Rail Worldwide repair and service for electrical rotating equipment We take care of it. Inhoudsopgave About Bakker Repair + Services 2 Inpections & Measurements Bakker Motor Circuit

More information

Switchgear and Distribution Systems for Engineers and Technicians

Switchgear and Distribution Systems for Engineers and Technicians Switchgear and Distribution Systems for Engineers and Technicians WHAT YOU WILL LEARN: How to identify typical characteristics of an industrial distribution system Become familiar with the main components

More information

PRODUCT CATALOG. Luneta.com

PRODUCT CATALOG. Luneta.com PRODUCT CATALOG Luneta.com 1 ABOUT US Luneta, LLC develops advanced machinery lubricant inspection technology for machine condition monitoring and reliability. Luneta s technology is designed primarily

More information

Steam Turbine Generator Core Isolation Issues at the Redhawk Combined Cycle Plant

Steam Turbine Generator Core Isolation Issues at the Redhawk Combined Cycle Plant Steam Turbine Generator Core Isolation Issues at the Redhawk Combined Cycle Plant Marques Montes Arizona Public Service Company Phoenix, AZ Includes material provided by John Demcko Redhawk Power Plant

More information

ACOUSTIC CLEANING SYSTEMS. Information Brochure.

ACOUSTIC CLEANING SYSTEMS. Information Brochure. ACOUSTIC CLEANING SYSTEMS Information Brochure www.aw-akustik.de Introduction to acoustic cleaning The operation principle of acoustic cleaning is based on high-energy sound waves generating pressure differences

More information

1.5KW DC-DC Converter Specification

1.5KW DC-DC Converter Specification 1.5KW DC-DC Converter Specification TDC-J Series V 3.2 Date 2016-10-14 1 Table of Contents 1 Overview 2 Basic functions 3 Technical Specifications 3.1 Product Naming 3.2 Model List 3.3 Model selection

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17579-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 07.07.2017 to 06.07.2022 Holder of certificate: gammatest

More information

Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by CGRS, Inc.

Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by CGRS, Inc. A New Standard in Preventive Leak Testing Service Provided by CGRS, Inc. Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by CGRS, Inc. Current Standards

More information

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps Abstract Samir M. Abdel-Rahman Dalia M. Al-Gazar M. A. Helal Associate Professor Engineer Professor Mechanical & Electrical

More information

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah Training Course : ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS Training Course For One Week In UAE, Sharjah, Copthorne Hotel Sharjah Which Be Held

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

Installation, User and Service Manual. Filter Unit WP1-B2-200

Installation, User and Service Manual. Filter Unit WP1-B2-200 Installation, User and Service Manual Filter Unit WP1-B2-200 Disclaimer: All rights reserved. No part of this publication may be reproduced, stored, or transmitted in any form or by any means, without

More information

Air Handling Unit Construction Checklist

Air Handling Unit Construction Checklist Air Handling Unit Construction Checklist Project: Date: AHU Tag: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

PORTAGAUGE 4 USER MANUAL

PORTAGAUGE 4 USER MANUAL PORTAGAUGE 4 USER MANUAL Contents 1. Introduction and Key Features 1.1 What does the Portagauge do? 1.2 The Portagauge 4 1.21 The Portagauge 4 Unit and Measuring Screen 1.22 The Portagauge 4 Definition

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

NZQA Expiring unit standard 893 version 5 Page 1 of 5. Diagnose and rectify vehicle emission control system faults

NZQA Expiring unit standard 893 version 5 Page 1 of 5. Diagnose and rectify vehicle emission control system faults Page 1 of 5 Title Diagnose and rectify vehicle emission control system faults Level 4 Credits 3 Purpose This unit standard is for people in the automotive repair industry. People credited with this unit

More information

Refrigerant air dryers FX 1-22

Refrigerant air dryers FX 1-22 Refrigerant air dryers FX 1-22 Air treatment, a crucial investment Why you need quality air Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often acidic,

More information

REFRIGERANT AIR DRYERS FX 1-22

REFRIGERANT AIR DRYERS FX 1-22 REFRIGERANT AIR DRYERS FX 1-22 AIR TREATMENT, A CRUCIAL INVESTMENT ATLAS COPCO QUALITY AIR, THE SMART CHOICE WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together,

More information

PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP

PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP PumpWorks HP-Plus APPLICATIONS Amine Fluid Transfer Gas Processing Mine Dewatering Pipeline Booster Saltwater Disposal Water Injection Water

More information

ALLMAC Electrical Eng. 61 (0) Advanced Infrared +61 (0) BES (Aust) Pty Ltd AUSTPTA

ALLMAC Electrical Eng. 61 (0) Advanced Infrared +61 (0) BES (Aust) Pty Ltd AUSTPTA page 1a ABB Australia 1800 222 435 Advanced Infrared +61 (0)425 758 820 ALLMAC Electrical Eng. 61 (0)419 819 756 Ampcontrol 1300 267 373 AUSTPTA www.austpta.asn.au BES (Aust) Pty Ltd 61 2 9686 4811 Products/

More information

Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System

Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System For SUITED COSTAL / EXPORT REFINERY PROJECTS 5-Km 450 NB (18 Dia.) Long Pipe Line

More information

High Voltage Technology & Testing

High Voltage Technology & Testing The Power of Trust. The Future of Energy. HIGH VOLTAGE TESTING Qualification testing, condition assessment, and forensic analysis Manufacturers and utility users of high-voltage electrical equipment face

More information

Variable Speed Pumping

Variable Speed Pumping Variable Speed Pumping Jim Vukich Application Engineer ITT Corp. Malvern, PA Why Do It? Why Do It? Flow-Matching Minimize Starting & Stopping Flexibility Different Discharge Points, Flows Changing Conditions

More information

Detection and evaluation of rail defects with nondestructive

Detection and evaluation of rail defects with nondestructive 19 th World Conference on Non-Destructive Testing 2016 Detection and evaluation of rail defects with nondestructive testing methods Anika DEY 1, Jochen KURZ 2, Lukasz TENCZYNSKI 3 1 DB Systemtechnik GmbH

More information

SIEMENS Transmission and Distribution

SIEMENS Transmission and Distribution TITLE Long Term Maintenance and Care for Reyrolle L800/1000T E. C. Wright 19/07/04 This document is to be used in conjunction with Installation, Operation and Maintenance Schedule IOMS 864. Its aim is

More information

APPLICATION OF AE TECHNIQUE AND THERMOGRAPHY FOR ASSESSMENT OF SLUDGE VOLUME INSIDE CRUDE OIL STORAGE TANKS

APPLICATION OF AE TECHNIQUE AND THERMOGRAPHY FOR ASSESSMENT OF SLUDGE VOLUME INSIDE CRUDE OIL STORAGE TANKS More info about this article: http://www.ndt.net/?id=23614 APPLICATION OF AE TECHNIQUE AND THERMOGRAPHY FOR ASSESSMENT OF SLUDGE VOLUME INSIDE CRUDE OIL STORAGE TANKS Ireneusz Baran 1, Tomasz Dunaj 1,

More information

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of

More information

Algeria, November 2016

Algeria, November 2016 Advanced Non-Destructive Testing for Tanks and Pipelines Algeria, November 2016 Params. K Details of Selected Advanced NDT Techniques On-Line Inspection What is On-Line Inspection? Check the Mechanical

More information

Multi-colour LED Status Light - using it as a diagnostic tool:

Multi-colour LED Status Light - using it as a diagnostic tool: All J+J electric actuators are tested prior to shipping. Most issues are site related, we hope that you will find a solution to your problem in this guide. If not, please contact us for support. Multi-colour

More information

ASME B31.3 Process Piping

ASME B31.3 Process Piping ASME B31.3 Process Piping Charles Becht IV, PhD, PE Don Frikken, PE Instructors BECHT ENGINEERING COMPANY, INC. In-Service Piping - 1 API 570 Piping Inspection Code Responsibilities What to Inspect Types

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 18438 02 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 11.03.2014 to 10.03.2019 Holder of certificate: Jürgen

More information

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures BACKGROUND RNRG worked with a large wind turbine owner in North America to demonstrate that the TurbinePhD condition monitoring system can detect faults early and reduce maintenance costs. An evaluation

More information

PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS

PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS Training Title PRACTICAL TROUBLESHOOTING OF ELECTRICAL EQUIPMENT & CONTROL SYSTEMS Training Duration 5 days Training Venue and Dates Practical Troubleshooting Of Electrical Equipment & Control Systems

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

OutdoorXUPS-600AHV-8364

OutdoorXUPS-600AHV-8364 OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide

More information

Fig 1. API Classification of base oils

Fig 1. API Classification of base oils SYNTHETIC VS MINERAL OIL Introduction Oil is the life blood of an engine and just like the blood in our bodies, it is required to fulfill a number of functions. Oil does not only lubricate, it also carries

More information

ABB AG, Transformers Active arcing fault protection system for dry-type transformers. ABB Group April 17, 2013 Slide 1

ABB AG, Transformers Active arcing fault protection system for dry-type transformers. ABB Group April 17, 2013 Slide 1 ABB AG, Transformers Active arcing fault protection system for dry-type transformers April 17, 2013 Slide 1 Active arcing fault protection system prevents arc faults When an arcing fault occurs in an electrical

More information

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications Contents 1. Laboratory Objective... 4 2. MECHANICAL OPERATION TESTS... 4 2.1 Purpose... 4 2.2 Procedure... 4 2.3 Results...

More information

Extensible Unit - VCE2a

Extensible Unit - VCE2a ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY

More information

30th International Conference on Electrical Contacts

30th International Conference on Electrical Contacts I N VI TAT I ON C A L L F OR A BST RACTS 30th International Conference on Electrical Contacts June 15th 18th, 2020 St. Gallen-Rorschach, Switzerland Cover: Switzerland Tourism ICEC2020 Electrical contatcs

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

SINAMICS GM150 IGCT version

SINAMICS GM150 IGCT version /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /14 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

Building the Ultimate Reliable Plant

Building the Ultimate Reliable Plant Reliable Process Solutions It Can Operate Forever GreenHunter Bio Fuels Inc. Houston, Texas Building the Ultimate Reliable Plant Presentation for UE Systems Conference 2009 Terry Harris, CMRP Certified

More information

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 2 Engines)

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 2 Engines) August 2016 ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 2 Engines) QUESTION: I recently had start-up assistance training on my Windrock analyzer. What are some

More information

Page 1 of 8 HW7 DTC P1443: CHECK THE VOLTAGE ON THE PURGE FLOW (PF) SENSOR CIRCUIT VOLTAGE WITH ENGINE RUNNING Continuous Memory Diagnostic Trouble Code (DTC) P1443 indicates an incorrect evaporative system

More information

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS Journal of Physics: Conference Series Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS To cite this article: H M Bari et al 2012 J. Phys.: Conf. Ser. 364 012022 View the

More information

ADVANCED PID TROUBLESHOOTING

ADVANCED PID TROUBLESHOOTING ADVANCED PID TROUBLESHOOTING August 29, 2016 A KEY POINT If the drive is telling you something via a Fault, then the problem is probably not the drive. The drive is recognizing a fault and telling you

More information

Interior Acoustics. Lecture delivered by: Kiran V. R. Asst. Prof. Dept. of AAE MSRSAS-Bangalore. M.S Ramaiah School of Advanced Studies - Bangalore

Interior Acoustics. Lecture delivered by: Kiran V. R. Asst. Prof. Dept. of AAE MSRSAS-Bangalore. M.S Ramaiah School of Advanced Studies - Bangalore Interior Acoustics Lecture delivered by: Kiran V. R. Asst. Prof. Dept. of AAE MSRSAS-Bangalore Outline of the Presentation Introduction to acoustics Different noise sources Types of vehicle noise Human

More information

DEP7007CC Compliance Certification

DEP7007CC Compliance Certification Commonwealth of Kentucky Natural Resources & Environmental Protection Cabinet Department for Environmental Protection DIVISION FOR AIR QUALITY DEP7007CC Compliance Certification Division Use Only ID# Permit

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

September 2008 TEC, INTELLIGENT MONITORING SYSTEM September 2008 TEC, INTELLIGENT MONITORING SYSTEM ABB BU Transformers - 1-10/9/2008 TEC, philosophy ABB BU Transformers - 2 - TEC was launched by ABB in year 2002 to improve transformers performance. More

More information

Fundamentals of Oil Analysis

Fundamentals of Oil Analysis IRC RESEARCH AND TECHNOLOGY FORUM Wednesday May 6, 2015 Thursday May 7, 2015 Madison, WI 53706 University of Wisconsin-Madison Pyle Center 702 Langdon St. University of Wisconsin-Madison Fundamentals of

More information

Industry Air Purification System

Industry Air Purification System Industry Air Purification System Oil + Emulsion Mist Collector Cleaned air Oil mist Oil recycle Integrated self cleaning system High and constant air purification performance Avoid frequent filter change

More information

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004 Page 1 of 7 Planned Maint. Type Turbo file - Job Group 1Y-DOWN Lead Trade Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004 Isolation Zone Supersedes References J:\PS\mep\Maintenance

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

On Board Diagnostics II A PCED

On Board Diagnostics II A PCED Page 1 of 8 HX18 DTC P0446 OR P1450: CHECK FOR VISUAL CAUSES OF EXCESSIVE FUEL TANK VACUUM Continuous Memory Diagnostic Trouble Code (DTC) P0446 or P1450 indicates that Self-Test has detected the Evaporative

More information

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter

More information

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks by Georges Barbarin Executive summary Aging electrical switchgear infrastructure is a threat to the reliability of power

More information

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 11/23/2013 2:25 PM

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 11/23/2013 2:25 PM Page 1 of 13 Caterpillar Electronic Technician 2012C v1.0 Product Status Report 2:25 PM Product Status Report Product ID Comments Implement Control #2 Product ID ECM Part Number 3045687-01 19086375MS ECM

More information

2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9

2006 Thermographic Inspection. Terrific Towers 1001 Sparks St Sydney. Vol. 9 8/139 Woolooware Rd Burraneer NSW 2230 T. (02) 9544 3588 F. (02) 9544 3688 E. info@thermalimagingservices.com.au W. www.thermalimagingservices.com.au Accredited Thermographers 2006 Thermographic Inspection

More information

Vacuum Furnace Pumping Systems

Vacuum Furnace Pumping Systems Vacuum Furnace Pumping Systems Failures and Solutions December 4, 2014 Presented By: William R Jones, CEO Solar Atmospheres Inc., www.solaratm.com Technical Contributors: Virginia M Osterman, Ph.D. Senior

More information

Compact, flexible, highest availability.

Compact, flexible, highest availability. Compact, flexible, highest availability. H-compact PLUS Motors Answers for industry. Strong performance in the smallest space. H-compact PLUS. First and foremost for any motor you must be able to depend

More information

YUTECH Infra Red Type Donnelly Chute Level Sensors and Indicating Transmitters

YUTECH Infra Red Type Donnelly Chute Level Sensors and Indicating Transmitters YUTECH Infra Red Type Donnelly Chute Level Sensors and Indicating Transmitters YU Technologies Pvt. Ltd. Registered Office: 315, A1, 22, Manishanagar, Off Sahyadrinagar, Sangli 416 416, Maharashtra, India.

More information

GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007

GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007 GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007 AMERICAN GLOVEBOX SOCIETY STANDARDS DEVELOPMENT COMMITTEE All Rights Reserved Copyright 2007 No portion may be duplicated without written consent

More information

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump. General 1 Model MS 9-2-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent VT4.25 vacuum pumps mounted on a common skid with expandable automatic alternating

More information

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy. Gas-insulated medium-voltage switchgear For the mining industry Answers for energy. Full power even under extreme conditions Reliable All over the world, the demand for mineral resources is increasing.

More information