Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Size: px
Start display at page:

Download "Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013."

Transcription

1 M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved

2 1 Contents Introduction... 1 Safety Considerations... 2 Operation... 4 Specifications... 5 Configuration... 5 Installation... 6 Maintenance... 7 The Need for a Pressure-balancing Line... 8 Disassembly / Reassembly... 9 Troubleshooting... Product Warranty Introduction Thank you for purchasing the Air Trap. This product has been thoroughly inspected before being shipped from the factory. When the product is delivered, before doing anything else, check the specifications and external appearance to make sure nothing is out of the ordinary. Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly. This air trap automatically drains high viscosity oil and condensate from air and gas lines and receiver tanks. Its unique design allows self-cleaning of the trap interior during each discharge cycle, and the large size orifice eliminates problems due to dirt and oil accumulation. If detailed instructions for special order specifications or options not contained in this manual are required, please contact for full details. This instruction manual is intended for use with the model(s) listed on the front cover. It is necessary not only for installation but for subsequent, maintenance, disassembly/reassembly and troubleshooting. Please keep it in a safe place for future reference.

3 2 Safety Considerations Read this section carefully before use and be sure to follow the instructions. Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel. The precautions listed in this manual are designed to ensure safety and prevent equipment damage and personal injury. For situations that may occur as a result of erroneous handling, three different types of cautionary items are used to indicate the degree of urgency and the scale of potential damage and danger: DANGER, WARNING and. The three types of cautionary items above are very important for safety: be sure to observe all of them as they relate to installation, use, maintenance, and repair. Furthermore, TLV accepts no responsibility for any accidents or damage occurring as a result of failure to observe these precautions. Symbols Indicates a DANGER, WARNING or item. DANGER WARNING Indicates an urgent situation which poses a threat of death or serious injury Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment / product damage WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions that may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT use the trap in excess of the maximum operating pressure differential. Such use could make discharge impossible (blocked). Use hoisting equipment for heavy objects (weighing approximately 20 kg or more). Failure to do so may result in back strain or other injury if the object should fall. Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Safety cautions continued on next page.

4 3 When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. Be sure to use only the recommended components when repairing the product, and NEVER attempt to modify the product in any way. Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids. Do not use excessive force when connecting threaded pipes to the product. Over-tightening may cause breakage leading to fluid discharge, which may cause burns or other injury. Use only under conditions in which no freeze-up will occur. Freezing may damage the product, leading to fluid discharge, which may cause burns or other injury.

5 4 Operation Principles of Condensate Discharge 1. Condensate and oil flow into and accumulate in the trap. 2. When the condensate level in the trap body rises to a certain point, the floats (B) rise. This, together with the help of the coil spring (E), lifts the float holder, causing the pilot valve (D) to open. 3. When the pilot valve (D) opens, compressed air (primary side) enters the pressure chamber (G) and pushes the piston (C) down, opening the main orifice (F) to discharge condensate and oil. The pressure inside the float cover (A) is lower than that outside, so the condensate outside the float cover discharges first, after which the condensate inside the float cover discharges. As the condensate inside the float cover discharges, some pressurized air will discharge with the condensate to flush out any oil or dirt in the trap and provide a self cleaning action. 4. When the condensate has been discharged, the floats (B) fall, causing the pilot valve orifice (D) to close. When the pilot valve orifice (D) closes, the pressure in the pressure chamber (G) is released to the outlet and the piston (C) rises to close the main valve orifice (F). Note: In this manner, inflowing condensate is intermittently discharged.

6 5 Specifications Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT use the product in excess of the maximum operating pressure differential; such use could make discharge impossible (blocked). Use only under conditions in which no freeze-up will occur. Freezing may damage the product, leading to fluid discharge, which may cause burns or other injury. Refer to the product nameplate for detailed specifications. Nominal Diameter Valve No.** Maximum Allowable Pressure* Maximum Operating Pressure Model Serial Number Minimum operating pressure: 0.2 MPaG * Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS. ** Valve No. is displayed for products with options. This item is omitted from the nameplate when there are no options. Configuration Maximum Allowable Temperature (TMA)* Maximum Operating Temperature (TMO) A: Pilot Valve No. Name No. Name No. Name No. Name No. Name 1 Body 10 Piston 18 Cover Gasket 28 Split Pin 37 Anchor Nut 2 Cover 11 Pilot Valve Seat 19 Slide Ring 29 Spring Washer 38 Caution 3 Outlet Union 12 Spring Holder 20 Main Valve O-Ring Balancing Line Faceplate 30 4 Float Cover 13 Main Valve 21 Piston Guide O-Ring Plug 39 Caution 5 Bottom Plate 14 Pilot Valve 22 Piston O-Ring 31 Sealing Spring Faceplate 6 Piston Guide 15 Snap Ring 23 Snap Ring 32 Opening Spring 40 Nameplate 7 Float Pilot Valve 24 Valve Seat Gasket 33 Nipple 41 Y-Strainer 16 8 Float Holder Support Plate 25 Cover Bolt 34 Elbow 42 Pipe Main Valve Outlet Union 26 Outlet Union Bolt 35 Mounting Base Strainer Seat Gasket 27 Castle Nut 36 Anchor Bolt Blow Valve

7 6 Installation DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. Use hoisting equipment for heavy objects (weighing approximately 20 kg or more). Failure to do so may result in back strain or other injury if the object should fall. Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Do not use excessive force when connecting threaded pipes to the product. Over-tightening may cause breakage leading to fluid discharge, which may cause burns or other injury. Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel. 1. Before installing the product, blow out the inlet piping to remove any piping scraps, dirt and oil. Close the inlet valve after blowdown. 2. Before installation, be sure to remove all protective seals. 3. Using the nipple, attach the Y-strainer to the inlet of the TATSU2 cover. 4. Install the product so that the arrow on the body is pointing in the direction of condensate flow. 5. Install the product with the trap body oriented vertically. The product should be inclined no more than 10 horizontally and front-to-back. 6. Install the product in the lowest part of the pipeline or equipment so that condensate flows naturally into the trap by gravity. 7. To insure proper condensate flow into the trap, remove the balancing line plug and install a pressure-balancing line. Connect the end of the pressurebalancing line to the air main or an area with an air pocket. For more details, see the section The Need for a Pressure-balancing Line. 8. If the compressor vibrates heavily, secure the product in place using anchor bolts. If there is a problem, determine the cause using the Troubleshooting section in this manual. Allowable angles of inclination for installation Air Trap Air Trap Anchor Bolt Anchor Bolt

8 7 Maintenance Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Be sure to use only the recommended components when repairing the product, and NEVER attempt to modify the product in any way. Failure to observe these precautions may result in damage to the product or burns or other injury due to malfunction or the discharge of fluids. Operational Check A visual inspection of the following items should be done on a daily basis to determine whether the product is operating properly or has failed. Periodically (at least biannually) the operation should also be checked by using diagnostic equipment such as a stethoscope. If the trap should fail, it may cause damage to piping and equipment, resulting in faulty or low quality products or losses due to leakage. Normal : When condensate accumulates inside the body, the valve opens and the sound of flow can be heard as the condensate discharges. The sound of air being discharged can then be heard, after which the valve closes. This cycle repeats. Blocked (Discharge Impossible) : A long time passes with no condensate discharged (no sound of flow, no discharge cycle is heard). Blowing Air Leakage : A large quantity of air continually flows from the outlet and there is a loud blowing sound. : When the trap valve is closed, a small amount of air is discharged through the trap outlet together with condensate, accompanied by a high-pitched hissing sound. Parts Inspection When parts have been removed, or during periodic inspections, use the following table to inspect the parts and replace any that are found to be defective. Procedure Gasket(s): check for warping and damage Screen: check for clogging and corrosion Floats: check for deformation Spring Holder: check for dirt or a dirty coating O-ring: check for warping and damage Pilot Valve Seat: check for dirt, wear and damage Surfaces that Seat with Pilot Valve: check for dirt, wear and damage Main Valve: check dirt, oil film, wear and damage

9 8 The Need for a Pressure-balancing Line This air trap is designed to automatically and intermittently discharge inflowing condensate. However, if the condensate completely fills the inlet path to the trap, air in the trap body will not be able to escape, preventing displacement by condensate, and thus preventing condensate from entering the trap. This phenomenon is called air binding. A pressure-balancing line installed between the trap cover and the dry portion of the receiver tank is used to prevent this phenomenon from occurring. Connect the pressure-balancing line in the following manner: Receiver Tank Air Main Pressurebalancing Line Union Pressurebalancing Line Union Air Trap Air Trap Note: Be sure to connect the pressure-balancing line to an area with the same pressure or to an air section downstream of the flow medium.

10 9 Disassembly / Reassembly WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. Use hoisting equipment for heavy objects (weighing approximately 20 kg or more). Failure to do so may result in back strain or other injury if the object should fall. When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. Use the following procedures to remove components. Use the same procedures in reverse to reassemble. (Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel.) Dissassembly / Reassembly Procedure NOTE: Disconnect any lines that must be disconnected before disassembly can take place (inlet piping, pressure-balancing line, condensate discharge piping, etc.). Remove the anchor bolts and move to an open space or work bench for disassembly. Part During Disassembly During Reassembly Y-Strainer Remove with a wrench Wrap threads on nipple with turns of sealing tape; reattach Cover Bolts Remove with an allen wrench Consult the table of tightening torques and tighten to the proper torque Cover Lift off of the body Set gently on the body Cover Gasket Remove; clean sealing surfaces Replace with a new gasket on cover and body Float Cover lift off of the bottom plate Set on the bottom plate s grooved track Float Holder Floats Lift straight off of the guide; be careful not to drop the floats Remove, being careful not to scratch the polished surface Slide onto the guide being careful not to drop the floats Insert carefully, taking care not to scratch or misshape Bottom Plate Lift off of grooved shelf in body Set on grooved shelf in body Outlet Union Bolts Remove with a hex key Consult the table of tightening torques and tighten to the proper torque Mounting Base Take off of the outlet union Place on the outlet union and align bolt holes Outlet Union Remove from the body being careful not to damage the piston or main valve; Align and reattach to the body Outlet Union Gasket Piston Unit (Piston, Piston Guide, Piston Valve Seat) Remove; clean sealing surfaces on the body and outlet union Carefully remove from the body; no further disassembly is advised Replace with a new gasket This unit should be considered one part; in times of malfunction, all parts should be replaced together Torque Tightening Table Part Torque (N m) Distance Across Flats (mm) Cover Bolt Outlet Union Bolt (1 N m 10 kg cm)

11 10 Troubleshooting WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. When the product fails to operate properly during operation, first confirm the following items: 1. Make sure that there is pressure at the trap inlet, and that the pressure is within the correct operating range. (Operating pressure range: MPaG) 2. Check to make sure that the pressure-balancing line is correctly installed. 3. Make sure that condensate is flowing into the trap. Lastly, make sure that the piping is configured in a way that allows condensate to flow freely into the trap. When the product fails to operate properly, use the following table to locate the cause and remedy. Problem Cause Remedy No The pilot valve seat is clogged with scale Clean parts condensate is discharged There is a build-up of scale between the piston and the main valve seat Clean parts (blocked) or There is a build-up of rust or scale between the float Clean parts discharge is holder and the piston guide poor The trap has the wrong number of floats (requires Inspect and replace 4), or the floats are damaged or full of condensate if necessary The vent hole in the float cover is clogged with rust Clean parts and scale The pressure-balancing line is clogged with rust and Clean parts scale The opening spring is broken Inspect and replace if necessary Air and/or condensate Scale has built up on the pilot valve seat or valve or the seating surfaces are scratched, crushed or worn Clean or replace parts* leaks from the Scale has built up on the main valve seat or main Clean or replace outlet between valve or the seating surfaces are scratched, crushed parts* or worn discharge The trap is subjected to direct heavy vibration from Inspect and anchor cycles the compressor if necessary (air leakage) The sealing surfaces of an O-ring are scratched or Inspect and replace damaged if necessary* Air is blowing There is a build-up of sticky scale between the float Clean parts and the valve does not holder and the piston guide The orifice of the piston is clogged with scale Clean parts close Scale has built up on the pilot valve seat Clean parts (blowing) The sealing spring is broken Inspect and replace if necessary Gaskets are deteriorated or damaged Replace with new gasket(s) Improper tightening torques were used Air is leaking from a place other than the outlet Tighten to the proper torque * The Piston Unit (Piston, Piston Guide, Piston Valve Seat) should be considered one part; in times of malfunction, all parts should be replaced together

12 11 Product Warranty 1. Warranty Period One year following product delivery. 2. Warranty Coverage TLV CO., LTD. warrants this product to the original purchaser to be free from defective materials and workmanship. Under this warranty, the product will be repaired or replaced at our option, without charge for parts or labor. 3. This product warranty will not apply to cosmetic defects, nor to any product whose exterior has been damaged or defaced; nor does it apply in the following cases: 1) Malfunctions due to improper installation, use, handling, etc., by other than TLV CO., LTD. authorized service representatives. 2) Malfunctions due to dirt, scale, rust, etc. 3) Malfunctions due to improper disassembly and reassembly, or inadequate inspection and maintenance by other TLV CO., LTD. authorized service representatives. 4) Malfunctions due to disasters or forces of nature. 5) Accidents or malfunctions due to any other cause beyond the control of TLV CO., LTD. 4. Under no circumstances will TLV CO., LTD. be liable for consequential economic loss damage or consequential damage to property. * * * * * * * For Service or Technical Assistance: Contact your representative or your regional office. Manufacturer CO., LTD. 881 Nagasuna, Noguchi Kakogawa, Hyogo JAPAN Tel: 81-(0)

Free Float Air Trap G8

Free Float Air Trap G8 172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1

More information

Manufacturer Kakogawa, Japan DC5S

Manufacturer Kakogawa, Japan DC5S ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1

More information

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 172-65144MA-05 (JA Series) 29 July 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 Copyright

More information

Float Dynamic Steam Trap J10

Float Dynamic Steam Trap J10 172-65237MA-01 (J10) 12 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Float Dynamic Steam Trap J10 Copyright 2015 by TLV CO., LTD. All rights reserved

More information

Surplussing Valve SP-COSR-16

Surplussing Valve SP-COSR-16 172-65409MA-00 (SP-COSR-16) 20 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Surplussing Valve SP-COSR-16 Copyright 2013 by TLV CO., LTD. All rights

More information

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N 172-65162M-03 (BT3N/MBT3N/PBT3N) 5 July 2013 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N Copyright 2013 by TLV CO., LTD. All

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES INSTRUCTION MANUAL Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES LV5 / LV13 / LV13L / LV13N / LV21 LV5 / LV13 / LV21 LV13L LV13N Manufacturer

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A. INSTRUCTION MANUAL Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HRA SERIES HR80A HR150A HR260A Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 6758511, Japan Tel:

More information

CV-COSR. Pneumatic Control Valve. Copyright 2013 by TLV CO., LTD. All rights reserved

CV-COSR. Pneumatic Control Valve. Copyright 2013 by TLV CO., LTD. All rights reserved 172-65587MA-00 (CV-COSR Pneumatic Control Valve) 28 March 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Pneumatic Control Valve CV-COSR Copyright 2013

More information

Bypass Blowdown Steam Trap (Free Float Steam Trap with X-element) J3S-X-BV / J3S-X-PB / J3S-X-MB

Bypass Blowdown Steam Trap (Free Float Steam Trap with X-element) J3S-X-BV / J3S-X-PB / J3S-X-MB 172-65594MA-01 (J3S-X-BV/J3S-X-PB/J3S-X-MB) 26 June 2015 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Bypass Blowdown Steam Trap (Free Float Steam Trap with X-element) J3S-X-BV

More information

Pneumatic Control Valve for Steam PN-COSR-16

Pneumatic Control Valve for Steam PN-COSR-16 172-65604MA-00 (-16 Pneumatic Control ) 10 September 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Pneumatic Control for Steam -16 Copyright 2014 by TLV

More information

GT5C. Copyright 2014 by TLV CO., LTD. All rights reserved MA-01 (GT5C PowerTrap) 16 October 2014 ISO 9001/ ISO

GT5C. Copyright 2014 by TLV CO., LTD. All rights reserved MA-01 (GT5C PowerTrap) 16 October 2014 ISO 9001/ ISO 172-65473MA-01 (GT5C PowerTrap) 16 October 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 GT5C Copyright 2014 by TLV CO., LTD. All rights reserved Contents

More information

GP5C. Copyright 2016 by TLV CO., LTD. All rights reserved MA-01 (GP5C PowerTrap) 23 August 2016 ISO 9001/ ISO

GP5C. Copyright 2016 by TLV CO., LTD. All rights reserved MA-01 (GP5C PowerTrap) 23 August 2016 ISO 9001/ ISO 172-65637MA-01 (GP5C PowerTrap) 23 August 2016 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 GP5C Copyright 2016 by TLV CO., LTD. All rights reserved Contents

More information

Motorized Pressure Reducing Valve for Steam COSPECT M-COS-3 / M-COS-16 / M-COS-21

Motorized Pressure Reducing Valve for Steam COSPECT M-COS-3 / M-COS-16 / M-COS-21 172-65188M-08 ( 3,16,21 Pressure Reducing ) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Motorized Pressure Reducing for Steam COSPECT -3 / -16

More information

High-precision Multi-control Valve for Steam COSPECT MC-COS-3/MC-COS-16

High-precision Multi-control Valve for Steam COSPECT MC-COS-3/MC-COS-16 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 High-precision Multi-control Valve for Steam COSPECT -3/-16 Actuator: MC-GA2 Copyright 2010 by TLV CO., LTD.

More information

MA-03 (GP10/GT10/GP14/GT14 PowerTrap) 28 January 2015 ISO 9001/ ISO GP10/GT10 GP14/GT14

MA-03 (GP10/GT10/GP14/GT14 PowerTrap) 28 January 2015 ISO 9001/ ISO GP10/GT10 GP14/GT14 72-6538MA-03 (GP0/GT0/GP4/GT4 PowerTrap) 28 January 205 ISO 900/ ISO 400 GP0/GT0 GP4/GT4 Copyright 205 by TLV CO., LTD. All rights reserved Contents Introduction...2 Safety Considerations... 3 General

More information

MA-04 (GP10/GT10/GP14/GT14 PowerTrap) 1 February 2019 GP10/GT10 GP14/GT14. Copyright 2019 by TLV CO., LTD. All rights reserved

MA-04 (GP10/GT10/GP14/GT14 PowerTrap) 1 February 2019 GP10/GT10 GP14/GT14. Copyright 2019 by TLV CO., LTD. All rights reserved 72-6538MA-04 (GP0/GT0/GP4/GT4 PowerTrap) February 209 GP0/GT0 GP4/GT4 Copyright 209 by TLV CO., LTD. All rights reserved Contents Introduction... 2 Safety Considerations... 3 General Description... 5 Operation...

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. PRESSURE REDUCING VALVES FOR STEAM COS/COSR Series.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. PRESSURE REDUCING VALVES FOR STEAM COS/COSR Series. INSTRUCTION MANUAL Keep this manual in a safe place for future reference PRESSURE REDUCING VALVES FOR STEAM COS/COSR Series COS-3/COS-16 COS-21 COSR-3/COSR-16 COSR-21 Manufacturer 881 Nagasuna, Noguchi,

More information

M-COSR-3 / M-COSR-16 / M-COSR-21

M-COSR-3 / M-COSR-16 / M-COSR-21 172-65189M-06 ( 3,16,21 Pressure Reducing Valve) 24 September 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Motorized Pressure Reducing Valve for Steam

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES Pamphlet M0000 COSPECTR PRESSURE REDUCING VALVES Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECT: Three-in-One Design A Product of Advanced Fluid Control Technology Three sub-units combine

More information

3M TM Filter Housing 1BS-T/1BS-TW Series

3M TM Filter Housing 1BS-T/1BS-TW Series READ FIRST 3M TM Filter Housing 1BS-T/1BS-TW Series Operation Manual CONTENTS Introduction 1 For Your Safety 1,2 Attention to galling or seizure of treaded portions 2 Specifications 3 Part names 4 Installation

More information

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc. ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

PowerTrap Manufacturer Kakogawa, Japan GP10L/GT10L

PowerTrap Manufacturer Kakogawa, Japan GP10L/GT10L 172-65043MA-02 (GP10L/GT10L PowerTrap) 9 March 2004 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 GP10L/GT10L Copyright 2004 by TLV CO., LTD. All rights reserved

More information

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

GP10L/GT10L GP14L/GT14L GP14M/GT14M

GP10L/GT10L GP14L/GT14L GP14M/GT14M 72-65043MA-0 (GP0L/GT0L/GP4L/GT4L/GP4M/GT4M PowerTrap) 22 November 207 GP0L/GT0L GP4L/GT4L GP4M/GT4M Copyright 207 by TLV CO., LTD. All rights reserved Contents Introduction... 2 Safety Considerations...

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Technical Manual EH 1.2 General Information about valve sizing: Valves with a Full Port have an internal seat diameter that is the same as the nominal pipe

More information

OPERATING SERVICE MAINTENANCE MANUAL

OPERATING SERVICE MAINTENANCE MANUAL OPERATING SERVICE MAINTENANCE MANUAL ALL-STAR ROCKING PISTON COMPRESSOR AND VACUUM PUMP Registered by one or more of these standards agency ISO RoHS 9001 Compliant CE Read through carefully and understand

More information

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL CARTRIDGE FILTER SYSTEMS OWNER S MANUAL Installation Operation Parts Designed, Engineered & Manufactured in the USA. 2017 Waterway Plastics 2200 East Sturgis Road, Oxnard CA 93030 Phone 805.981.0262 Fax

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING

More information

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: G-H, G-HL, G-K, G-KK, G-L, G-LQ, G-LL, GLS, G-Q, G-QS 1 Contents Maintenance Thrust bearing adjustment

More information

MC-COSR-3/MC-COSR-16

MC-COSR-3/MC-COSR-16 172-65185A-08 ( Multi-control Valve) 20 November 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 High-precision Multi-control Valve for Steam -3/-16 Actuator:

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing

More information

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

Telescopic Transmission Jacks

Telescopic Transmission Jacks Telescopic Transmission Jacks Operating Instructions & Parts Manual Model Number BH7051 BH7055 (Air/Manual) Capacity 1/2 Ton 1/2 Ton SFA Companies 2006 10939 N. Pomona Ave. Kansas City, MO 64153 816-891-6390

More information

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL IMPORTANT These instructions are intended as a guide for the Installing Contractor and as a reference for the Operator, Owner and Serviceman. RETAIN

More information

PT-516 Pumping Trap Installation and Maintenance

PT-516 Pumping Trap Installation and Maintenance PT-516 Pumping Trap Installation and Maintenance IB-104-B This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the PT-516 Pumping Trap or Pumping Trap

More information

Battery Powered Hydraulic Pump; Kit PN [ ]

Battery Powered Hydraulic Pump; Kit PN [ ] ORIGINAL INSTRUCTIONS Battery Powered Hydraulic Pump; Kit PN 1804111-[ ] Customer Manual 409-10060 16 NOV 16 Rev D SAFETY PRES IMPORTANT SAFETY INFO READ THIS FIRST!... 2 SAFETY PRES AVOID INJURY READ

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

Pump Operating and Maintenance Manual - Models

Pump Operating and Maintenance Manual - Models Pump Operating and Maintenance Manual - Models 78-00111 - 78-0057 Thank you for purchasing the SDI Diaphragm Pump manufactured by Comet Pump. Comet produces quality products which are safe, efficient and

More information

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1 TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES hle, ate and ale SECTION TSM 710.1 PAGE 1 of 8 ISSUE B CONTENTS Introduction....................... 1 Safety

More information

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4- 4 (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. FEATURES Pilot operated characterized Modulating Plug

More information

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual 3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

Diaphragm Valves Type 15

Diaphragm Valves Type 15 Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

P239-1 Supply Pumper Instructions

P239-1 Supply Pumper Instructions P239-1 Supply Pumper Instructions STOP! READ THIS SECTION NOW. The following information is critical to the proper installation and operation of this Oil Supply System! Read it carefully before starting

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual API 6D Piston Check Valve - IOM: Installation, Operation and Maintenance Manual 1/16 Table of Contents 1 INTRODUCTION... 3 1.1 SCOPE... 3 1.2 DISCLAIMER...

More information

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual Serial No. H-V019-E-6 Constant Flow Valves User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation

More information

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual MECHANICAL FUEL METER FM-100 and FM-200 Series Owner s Manual To the owner Congratulations on receiving your GPI Mechanical Fuel Meter. We at GPI are pleased to provide you with a fuel meter designed to

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...3 Operation...4 Maintenance...5 Repair...5 Troubleshooting...9

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction Mechatronics Group OPERATION MANUAL Diaphragm Pump TD/TD2 Series TD-08, 15, 20/TD2-25 Thank you for purchasing Diaphragm Pump. Introduction This operation manual describes how to ensure safe and prolonged

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe

More information

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2 to 1 1/2 add 2 1/2 to 'C' dimension. 428 Jones Boulevard Limerick Airport Business Center Pottstown, PA 19464 Phone: (610)495-5131 ax: (610)495-5134 www.watsonmcdaniel.com PAGE 28 INSTRUCTION PART NO. 2315400 C.R.3500 REV. 10 SIZE C B CENTER

More information

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar Single Acting Hydraulic Aluminium Pull Cylinders RAP Series Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au

More information

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL SRM00046, should be read thoroughly prior to pump installation, operation or maintenance. Manual No. SRM00095

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

3-Way Ball Valve Type 23H

3-Way Ball Valve Type 23H Serial No. H-V062-E-4 contents 3-Way Ball Valve Type 23H User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,

More information

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION 30/8.5.1 INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION VKP PILOT OPERATED PRESSURE REDUCING VALVE 12501 Telecom Drive, Tampa, Florida 33637 1. Introduction The Class VKP pilot-controlled steam

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2 10 IOM-F-860_880V INSTALLATION, OPERATION, MAINTENANCE Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10" 860 880V Standard Configuration 880V Vertical Configuration INDEX Vandalism..............................................

More information

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS X-SERIES TRIPLEX CERAMIC PLUNGER PUMPS OPERATING MANUAL MODELS X8 X10 X20 IMPORTANT OPERATING CONDITIONS Failure to comply with any of these conditions invalidates the warranty. Lubrication - Prior to

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A WATTS INDUSTRIES, INC. Technical Data SD 4512A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 4512A/9806 T124/T134 PILOT FRONT VIEW 2 1 /16 F 5 7 /8 2 3

More information

Wastewater Air Release Valve Models 48A, 49A

Wastewater Air Release Valve Models 48A, 49A Manual No. WWAR-OM1-2 Wastewater Air Release Valve Models 48A, 49A Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

Portable Oil Free Silent Series Compressor Operating Instructions

Portable Oil Free Silent Series Compressor Operating Instructions Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com

More information

Thank you for selecting the GD submersible grinder pump.

Thank you for selecting the GD submersible grinder pump. GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 ) I & M Mark 8 Series 0 Wasson Road Cincinnati, OH 4509 USA Phone 5-5-5600 Fax 5-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (-/ - ) Warning:

More information

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures

More information

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup. Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important

More information

1451 Control Valve. General Instructions. Table of Contents

1451 Control Valve. General Instructions. Table of Contents 1451 Control Valve General Instructions The SOR 1451 Freezeless control valve is a high-pressure, reverse-seating liquid control valve typically used in separators and other process vessels. The body screws

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416 MODEL HD-BTC Installation, Operation & Repair Parts Information REV041416 TABLE OF CONTENTS SAFETY INSTRUCTIONS 1 DEFINITIONS 1 SPECIFICATIONS 2 INSTALLATION INSTRUCTIONS 2 OPERATING INSTRUCTIONS 2 MAINTENANCE

More information

Butterfly valves Figure 56 Installation & Maintenance Instructions

Butterfly valves Figure 56 Installation & Maintenance Instructions KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON MINING DIVISION NYLON & PVC VALVES PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE NYLON For Gold Mines DESCRIPTION The valve maintains a preset downstream pressure, regardless of upstream pressure

More information

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust INSTRUCTION MANUAL NOTE TO INSTALLER : PLEASE GIVE THIS MANUAL TO THE CUSTOMER AFTER INSTALLATION. AUTOMATIC FAUCET Important Safeguards Precautions Model Number and Components Before Use How to Use How

More information

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT Instruction D10497 April 2015 BHP High Performance Butterfly Valves (S2, S3, S5, AA, HC, ML, T2 & T5 Shafts) Instructions These

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 ) I & M Mark 8 Series 30 Wasson Road Cincinnati, OH 4509 USA Phone 53-533-5600 Fax 53-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (/ -

More information

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve... Priming Systems Installation Priming Systems Operation & Maintenance Form No. F 1031 Section 2312 Issue Date 10/07/94 Rev. Date 02/27/06 Table of Contents Illustrations Principals of Operation...........................

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500 VSI INDUSTRIAL BALL BUTTERFLY VALVES VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500 INSTALLATION, OPERATION AND MAINTENANCE MANUAL

More information

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2) Installation & Maintenance Instructions -- WAY DIRECT-- ACTING SOLENOID VALVES REVISION H & R NORMALLY OPEN OR NORMALLY CLOSED OPERATION BRASS OR STAINLESS STEEL CONSTRUCTION -- 1/8I, 1/4I, OR3/8I PIPE

More information

Electric Diesel Pump EDP/12, EDP/24

Electric Diesel Pump EDP/12, EDP/24 INSTRUCTION MANUAL Electric Diesel Pump EDP/1, EDP/4 S1940, Rev C Congratulations on purchase of this World Class Electric Diesel Pump! Portable Diesel transfer pumps designed for everyday use in Agricultural,

More information

POSITIVE DISPLACEMENT FLOWMETERS

POSITIVE DISPLACEMENT FLOWMETERS MS345BR 0408 0001 POSITIVE DISPLACEMENT FLOWMETERS M4 BRONZE SERIES INSTRUCTION MANUAL M4 Pulse; M4 Standard LCD; M4 Deluxe LCD; From serial No.CXXXX TO THE OWNER Please take a few minutes to read through

More information

ACTIVAL Two-way Ball Valve with Threaded-end Connection

ACTIVAL Two-way Ball Valve with Threaded-end Connection Specifications/Instructions ACTIVAL Two-way Ball Valve with Threaded-end Connection General ACTIVAL Model VY5302A is a two-way ball valve with threaded-end connection (ISO 7-1: 1994). It proportionally

More information

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No. Doc. No. APP 003U-03 INSTRUCTION GREASE PUMP PD110A50T MODEL No.851728 PD110A50T-SL MODEL No.851999 PD110A50 MODEL No.851779 DR110A50 MODEL No.851783 WARNING Prior to operating this pump, be sure to read

More information

ROOTS Meters Series B3 Meter Models 8C175-56M175

ROOTS Meters Series B3 Meter Models 8C175-56M175 ROOTS Meters Series B3 Meter Models 8C175-56M175 Refer to IOM-B3 for Complete Instructions IS:B3 3.03 RECEIVING, HANDLING AND STORAGE ROOTS rotary positive displacement gas meters are precision measurement

More information

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424 PEM8414 PEM8424 Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au

More information

t EVAPORATOR PRESSURE REGULATING VALVES

t EVAPORATOR PRESSURE REGULATING VALVES CATALOG 201 Page 63 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-12, -15 and -20 Features n High side pilot for improved temperature control and low P operation n Adjustable n Optional solenoid stop

More information

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair procedures for

More information