1 Instructions / / 1-9 Instruction and Maintenance Manual Self-priming Centrifugal Pumps Type S Index A. Declaration of Conformity 2 B. Introduction 3 C. Operation 5 D. Automatic Grease Lubricator 8 E. Electric Motor 9 Spare Part List Annex Pump No.

2 Instructions / / 2-9 A. Declaration of Conformity We hereby declare that the self-priming centrifugal pumps type S comply with the following relevant requirements: EC Machinery Directive 2006/42/EC, Appendix II A. Pumps without a drive unit are intended to be connected to other machines. It is forbidden to start-up the machine in which the pump is installed if the machine has not been declared conform to the above named EC Directives. By pumps with a drive unit that are modified and/or are not used for the purpose intended, will render null and void the validity of this declaration of conformity. The following standards have been found helpful and have been used in their entirety or in part: EN 809:2009 EN ISO 12100:2010 Person authorized to form the technical documentation: Victor Pumpen GmbH, Dieselstr. 7, Kirchheim, Germany. Date: Victor Pumpen GmbH Dieselstr Kirchheim Germany Paolo Varisco Ceo

3 Instructions / / Introduction B. Introduction 1.1 The instruction manual contains important information on how to operate the pump safely, properly and most efficiently. Observing these instructions helps to avoid danger, to reduce repair costs, downtimes and to increase the reliability and life of pump. 1.2 The operating instructions must always be available wherever the pump is in use. 1.3 The operating instructions must be read and applied by any person in charge of carrying out work on the pump. 1.4 Observe the mandatory rules and regulations for accident prevention and environmental protection in the country and place of use of the pump. The generally recognized technical rules for safe and proper working must also be observed. 1.5 It is presumed that fundamental project work as well as all work with regard to transport, assembly, installation, start-up, maintenance and repair is performed by qualified personnel or supervised by skilled labor taking overall responsibility. 2. Safety 2.1 A pump that is installed incorrectly, operated wrongly, or maintained poorly can present a hazard. If the following considerations are overlooked, the safety of personnel or satisfactory operation of the pump may be endangered. 2.2 Attention must be given to the safe handling of all items. Where pumps, pump units or components weigh in excess of 20 kg (44 lb.), it is recommended that suitable lifting equipment should be used in the correct manner to ensure that personal injury or damage to pump components does not occur. WARNING Note that lifting eyes fitted to individual pieces such as pump and motor are designed to lift only this part and not the complete assembly. 2.3 Before starting to dismantle a pump all relevant and appropriate safety precautions must be taken, particularly if the pumps have been handling hazardous or toxic products. Seek advice from your safety officer or the manufacturer if you have any doubts. 2.4 Always wear adequate protective clothing and eye protection when dismantling pumps that have been used to pump toxic or hazardous products. Breathing apparatus may be necessary. 2.5 Always isolate the pump electrically before dismantling. Ensure that the electrical switch gear cannot be operated whilst any work is being carried out on the pump. 2.6 Always drain the pump casing of product before removing the pump from its associated pipework. 2.7 Flush out the pump casing and shroud with a compatible flush and drain away to a safe area. 2.8 Check with your process people to see if any special decontamination procedures have to be followed before working on a pump. 2.9 All pumps returned for factory servicing must be decontaminated and labeled to inform what precautions should be taken before dismantling. 3. Shipment inspection 3.1 Pumps and units are shipped suitably protected to prevent damage in transit from normal handling. When received, the shipment should be inspected immediately. Damages to the packaging or crating that may reveal content damages when unpacked should be reported to the carrier and possibly photographed. 3.2 A photograph is helpful in any claims to be made against the carrier. Inform manufacturer or the local authorized distributor, too.

4 Instructions / / Shipment shortages, checked against the transport documents, should be reported to the carrier. 3.4 Check the nameplate data against the shipping papers and against your purchase order to ensure that the proper pump is provided. 4. Storage 4.1 After receipt and inspection, a pump not immediately installed should be repackaged and placed in suitable storage. 4.2 Protective coatings on unpainted surfaces should be inspected and left intact. Unpainted surfaces, not factory treated with a rust inhibiting coating, should have a protective coating applied. 4.3 Plastic or gasket type port covers should be left in place. 4.4 Pumps should be stored in a clean, dry location. When moist, dusty atmosphere must be used for storage, further protect the pump with a moisture repellent cover. 4.5 If the pump has been used please empty the pump casing by opening the clean-out cover or plug and fill with some corrosion inhibiting oil. WARNING Never forget water inside pump casing during cold weather! Water may freeze and break the pump casing!

5 Instructions / / 5-9 C. Operation 1. Installation 1.1 Set up the pump on a flat surface as near as possible to the liquid to be pumped. Make sure that the surrounding is adequately ventilated. 1.2 Suction hose or pipe should be as short as possible and should have the same diameter as the pump port. It is recommended minimize the use of curves, corners or necks. This will reduce the priming time and ensure full capacity. 1.3 Check that any connections (threads, welds, gaskets, quick-couplings, valves, etc.) are completely airtight: if necessary, coat them with grease. 1.4 If present mount and fill the oil reservoir with oil or mount the automatic grease lubricator (see section D Automatic Grease Lubricator, on page 8). 1.5 It is a good advice to use a suction strainer without valve (available on request). 1.6 Connect the electric motor with authorized personal only (see section E Electric Motor, on page 9). 2. First Start-up 2.1 Use the pump only in the authorized performances levels indicated in performance curve, technical datasheet and instructions! The liquid should never be pumped on the limit of vaporization, crystallization, polymerization or solidification. 2.2 The material of the pump must be compatible with the pumped liquid. The pump manufacturer has no responsibility on this. 2.3 To self-prime the first time: Open the priming cover on the top of the pump. Fill the pump chamber completely with the liquid to be pumped. Close the cover. 2.4 Check that direction of rotation is the same as shown by the arrow on the back of the pump (clockwise when looking from the shaft or motor end). 2.5 Open all valves. Otherwise the mechanical seal can be damaged. 2.6 Start the pump and check after some minutes if the pump is working as planned. WARNING Any deviation from normal operating conditions (increased power consumption, temperature, vibrations, noise etc.) or warning signals by monitoring equipment suggest malfunction. Inform the responsible maintenance personnel at once to prevent the trouble from getting worse and causing, directly or indirectly, serious physical injury or material damage. In case of doubt disconnect the machine immediately! 3. Running 3.1 Start and stop the pump if necessary. The pump is designed for 6 starts per hour. More frequent start cycles must be approved by the pump producer. 3.2 If the suction line is empty, the pump will first suck in the air and then the liquid. 3.3 In case of pump stop, the integrated non-return valve (if present) prevents the flow back of the liquid. 4. Operating troubles 4.1 PUMP DOES NOT PRIME (a) Air leaks into the suction line (through couplings, threads, flanges, gaskets, hose clips, cuts, etc.). It is difficult to find the trouble place. You can take off the suction pipe from the suction port, start the pump and check if the pump sucks by placing the hand on the suction port. (b) Level of liquid inside pump casing is too low or empty.

6 Instructions / / 6-9 (c) Wrong direction of rotation or too low speed. (d) Overpressure in the delivery line. Air does not escape. Exhaust air through priming cover or install an automatic air-release valve. (e) Liquid inside pump chamber overheated. Allow liquid to cool down or refill it with cold liquid. (f) Air leaks through the mechanical seal because of damage or lack of lubrication. Replace the mechanical seal. (g) Leading edge of the volute is worn out by the abrasive action of the liquid. (h) Clogged, broken or worn impeller. 4.2 LOW CAPACITY (a) Strainer or filter clogged. Clean out. (b) Suction or delivery lines clogged or rubber hose collapsed. Locate and remove obstruction. (c) High friction losses in the line. Get rid of unnecessary curves, valves and constrictions. (d) Static suction lift too high. Place the pump as close as possible to the surface of liquid to be pumped. (e) Low rotation speed. Increase RPM. (f) Impeller clogged. Free impeller through the inspection cover or open the pump casing. (g) Impeller and/or wear plate(s) worn out. Replace. 4.3 PUMP IS MAKING NOISE (a) Discharge side or suction side closed or clogged. Install a manometer and a vacuum meter to inspect the piping. (b) Impeller clogged. Free impeller through the inspection cover or open the pump casing. (c) Cavitation. The pump is working outside the allowable curve. Check how the sound changes by slowly closing and opening the valve in the discharge side. (d) Ball bearing worn out; replace. 4.4 PUMP IS LEAKING (a) Loosen screws. Check. (b) Loads on the pump and piping to high. Check. (c) Overpressure. Mechanical seal damaged. (d) Dry-running or closed lines. Mechanical seal overheated and broken. Replace. (e) Rubber components not compatible with the pumped liquid. Please contact your pump partner for alternatives materials. 4.5 For any other operation troubles, please contact your pump partner by mentioning: Pump type Serial no. Problem Running time And possibly attach photographs of pump and piping. 5. Maintenance 5.1 After start-up the pump will need to be checked at the following intervals to make sure it is pumping properly and with regard to pump noise: 10 min. / 1 hour / 10 hours / 1 day / 1 week / 1 month. Inspection may take place thereafter at monthly intervals provided the conditions of use do not change.

7 Instructions / / 7-9 WARNING When pump is not used, never forget water inside the pump casing during cold weather! Water may freeze and break the pump casing! 5.2 Each 3 months, if necessary, lubricate the mechanical seal (see section 5 Lubrication of the mechanical seal on page 7). 5.3 Each 6 months open the inspection cover or the casing and check inside. Remove possible foreign parts blocked inside the casing. Clean the pump and the motor. If necessary, check more frequently. 5.4 Each 12 months, if necessary, change the automatic grease lubricator (see section D Automatic Grease Lubricator, on page 8). 5.5 Each 5-10 years make a general pump recondition. 6. Lubrication of the mechanical seal 6.1 Pumps with carbon seal (i.e..30. /.302. /.35. /.10. /.16. /.55.) have no lubrication and do not need any maintenance. 6.2 The models with mechanical seal with diamond coating (.36.,.362.) have no lubrication and therefore need no maintenance. 6.3 For models with automatic grease lubricator please follow the instructions in section D Automatic Grease Lubricator, on page Models with grease nipple do not need any maintenance for the first 200 working hours. After this period lubricate each 3 months with only one hub of grease. Use standard grease with viscosity grade between 1 and 3. With alkaline products (ex. lime-milk) use the special grease of Victor Pumps (please contact your Pump partner). WARNING Do not over-grease, otherwise the narrow ball bearing can be damaged! 7. Warranty 7.1 The manufacturer warrants the pump against defects or faulty workmanship for a period of 12 months from the date of delivery. Longer warranty periods are available on request. 7.2 Repair of the pump or replacement of parts or of the pump itself can only be carried out after careful examination of the pump in our workshop where the pump should be sent by carriage paid. Any exceptions must be confirmed in writing. 7.3 This warranty does not cover parts damaged by improper operation, handling and assembly, as well as parts subjected to deterioration and normal wear (especially impellers, wear plates and mechanical seals). 7.4 This warranty is no longer valid if the pump is disassembled or modified without the authorization of the manufacturer. WARNING Never forget water inside pump casing during cold weather! Water may freeze and break the pump casing!

8 Instructions / / 8-9 D. Automatic Grease Lubricator 1. Description 1.1 The automatic lubricator (+PS) is a long-term grease dispenser activated by a hydrogen gas producing dry cell. The lubricator contains 125 ml of grease dispensed during a period of 12 months. The operating temperature is min -20 C and max +55 C (-4/+131 F). The weight of the full lubricator is approx. 190g (6.7oz) and empty approx. 75g (2.7oz). The grease is special water-repellent, suitable for alkaline products. 1.2 Storage time of the cartridge should not be longer than 3 years. 2. Installation and activation 3. Notes 2.1 Open the lubricator outlet by removing the plug. 2.2 Screw the lubricator in the hole with ¼ thread on the head of the pump. If the hole is already closed by a tap or grease nipple take this part away. If necessary, use the extension to mount the lubricator. 2.3 Set the gas generator to position 12 (12 months) using a size 3 mm Allen key. 2.4 With a waterproof pen register the starting date on the label. The life time of the lubricator is 12 Months. Replace afterwards the empty lubricator with the same type. 3.1 After activating it can take some days, until grease is dispensed for the first time. 3.2 The lubricator can be readjusted or switched off (position 0) during operation. If you unscrew the lubricator the created pressure in the quench chamber will be lost and the life time of the lubricator will be less. 3.3 In order for the lubricator to function reliably it is important to have the quench chamber already filled with grease. If you change the mechanical seal it is important to refill the quench chamber and the line before installing the lubricator. 4. RECYCLING 4.1 Unscrew gas generator from the lubricator and dispose the complete part in the battery recycling. WARNING Do not unscrew the gas generator from the lubricator near a naked flame. 4.2 Dispose of empty housing of the lubricator in the PET-recycling. If the lubricator still contains grease, please dispose it in accordance with the local regulations.

9 Instructions / / Introduction E. Electric Motor 1.1 This section is valid only for close coupled pumps. For all other type of pumps, please see the separate motor instruction manual. 1.2 The close coupled motor is equipped with stronger ball bearings and an extended shaft that is also the pump-shaft. The motor can be bought only through the pump manufacturer. 2. Electric connection 2.1 Check the voltage and frequency with the technical information on the motor label. 2.2 Make a secure connection to earth. 2.3 Close unnecessary cable entries to close the box dust and waterproof. 2.4 Mount a safe overload switch. Set the motor overload switch to the nominal current +10%. WARNING The pump can be blocked by solids. To prevent damages always connect the motor through an overload switch. 2.5 Connect the motor following the wiring diagram. If necessary, change the motor rotation by inverting 2 Phases. 3. Maintenance 3.1 Clean the motor from dust (risk of overheating). 3.2 Clean the motor fan.

10 S Spare Parts List S Pumps S E 06/07/17 Ref. Part Name Rif. Part Name 01 Casing 25 Mechanical Seal 02 Wear Plate 26 Clean Out Cover 03 Impeller 27 Gasket (Clean Out) 04 Bracket 33 Nut Impeller 06 Bearing Housing 40 Volute 06.1 Foot, Bearing Housing 41 Gasket, Volute 07 Shaft 42 Gasket, Wear Plate Rear 08 Bearing Cover 43 Gasket, Casing 09 Wear Plate rear (with 42) 44 Gasket, Seal Box 10 Suction Valve 58 Ball Bearing, outer 14 Check Valve 59 Ball Bearing, inner 16 Drain Cover or Plug 64 Sleeve, inner 17 Gasket (Drain) 66 Impeller Washer 18 Seal Box 70 Grease Lubricator 19 Head 80 Electric Motor (with 33,66) 20 Seal box flange 83 Foot, Bracket 21 Discharge Flange 93 Coupling Half 22 Gasket Discharge Flange 94 Rubber Part 23 Priming Cover or Plug 95 Coupling Half 24 Gasket (Priming) Gasket set (with 14,17,22,27,41,42,43,44) GERMANY Tel Fax germany@victorpumps.com ITALY Tel Fax italy@victorpumps.com

11 Deutschland Victor Pumpen GmbH Dieselstr Kirchheim bei München Tel. +49 (0) Fax +49 (0) Italia Victor Pumps srl Viale Svezia Ponte S. Nicolò (Padova) Tel Fax

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instructions 6101794 / 12.03.2010 / 1-9 Instruction and Maintenance Manual Self-priming Centrifugal Pumps Type S Index A. Declaration of Conformity 2 B. Introduction 3 C. Operation 5 D. Automatic Grease

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instructions 16072896 / 11.08.2017 / 1-12 Instruction and Maintenance Manual Self-priming Centrifugal Pumps Type S in ATEX version Index A. Declaration of Conformity - ATEX certificate 2 B. Introduction

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instructions 16072897 / 11.08.2017 / 1-17 Instruction and Maintenance Manual Internal Gear Pumps Type R in ATEX version INDEX A. Declaration of conformity ATEX certificate 2 B. Introduction 3 C. ATEX -

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding Installation, Operating, Maintenance & Safety Instruction for M PUMPS CM MAG-M SERIES Centrifugal light Mag-Drive pumps (CM MAG-M06/1/2/3/4) This manual presents installation, servicing, troubleshooting,

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

2 Ton - 50 Ton Bottle Jack

2 Ton - 50 Ton Bottle Jack Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Instructions for installation, operation and maintenance of: GATE VALVE

Instructions for installation, operation and maintenance of: GATE VALVE Instructions for installation, operation and maintenance of: GATE VALVE GEN GAC GAF/GENF TERMOVENT SC Temerin Republic of Serbia Instruction for installation, operation and maintenance: Table of Contents

More information

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps 4100 Series Operating Manual Contents: Model Number/Serial Number Pg. 1 Safety Information Pg. 2 Operating Instructions

More information

80 Litre Suction Oil Drainer With Inspection Chamber

80 Litre Suction Oil Drainer With Inspection Chamber Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

MV Series Motors Operation & Parts Manual

MV Series Motors Operation & Parts Manual MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson

More information

SYDEX / MAINTENANCE AND OPERATION MANUAL

SYDEX / MAINTENANCE AND OPERATION MANUAL Installation Operation and Maintenance Attention: The following explanations have the aid to give you all possible information over the SYDEX pumps range. The right choosing of the pump is depending from

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: june 25, 2015 Supersedes: 40.80 Date: october 10, 2009 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4 2.0

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

EF SERIES MOTORS OPERATION & PARTS MANUAL

EF SERIES MOTORS OPERATION & PARTS MANUAL EF SERIES MOTORS OPERATION & PARTS MANUAL Models S1, S2, S3, S4 S1, S2, S3 S4 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

TBP SERIES PUMPS OPERATION & PARTS MANUAL

TBP SERIES PUMPS OPERATION & PARTS MANUAL TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

US - UP2/OIL 12V US - UP2/OIL 24V

US - UP2/OIL 12V US - UP2/OIL 24V SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING LUBRICATING OILS OR VISCOUS FLUIDS INSTRUCTIONS FOR USE 164 220 12-US - UP2/OIL 12V 164 220 13-US - UP2/OIL 24V 15/05/14 Rev.02 A PRODUCT DESCRIPTION Self-priming

More information

PF SERIES PUMPS PFS OPERATION & PARTS MANUAL

PF SERIES PUMPS PFS OPERATION & PARTS MANUAL PF SERIES PUMPS PFS OPERATION & PARTS MANUAL For Serial Number 162859 & above EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Setting Innovative Standards M PUMPS SRL Via dell artigianato, 120 45015 Corbola (RO) Italia Tel. +39 0426 346304 Fax + 39 0426 349126 1 info@mpumps.it MAGNETIC DRIVE PUMPS Centrifugal, peripheral, mag-drive

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS IMPORTANT - WARRANTY CLAUSE ROTECH PUMPS: Pumps manufactured & assembled by Rotech, are covered by warranty for free of manufacturing

More information

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

TM SERIES MIXER TMS OPERATION & PARTS MANUAL TM SERIES MIXER TMS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

X.. Series Helical and Bevel-Helical Gear Units

X.. Series Helical and Bevel-Helical Gear Units SEW-EURODRIVE Easy Guide Industrial Gear Units X.. Series Helical and Bevel-Helical Gear Units Edition 05/2018 24803731/ EN 2/16 Gear unit structure 1 Safety notes 2 Gear unit designs 3 Mounting positions

More information

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 This manual forms an integral part of the pump and must accompany it until its demolition. The series FMP peristaltic pump is a machine destined

More information

Pump Operating and Maintenance Manual - Models

Pump Operating and Maintenance Manual - Models Pump Operating and Maintenance Manual - Models 78-00111 - 78-0057 Thank you for purchasing the SDI Diaphragm Pump manufactured by Comet Pump. Comet produces quality products which are safe, efficient and

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS (Rev. 2.0_10-2010) DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS TRVK 2003 to 5003 TRSK 2005 to 5005 INTRODUCTION These instructions are for the maintenance staff in case of repair

More information

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual

More information

Portable Electric/Gas Compressor Operating Instructions

Portable Electric/Gas Compressor Operating Instructions Portable Electric/Gas Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 TABLE OF CONTENTS Safety

More information

EF SERIES PUMPS OPERATION & PARTS MANUAL

EF SERIES PUMPS OPERATION & PARTS MANUAL EF SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Water pump Owner's Manual

Water pump Owner's Manual Water pump Owner's Manual Safety Precautions I. General Safeguards Please read this operation manual to have a thorough understanding of the content there before use the product. Failure to do so may lead

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF Lift Check Valves according to European Norms [CLEN] Table of Contents 1. General safety information s 3 2. Product description 3 3. Transport

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual Centrifugal Pump SPC75 & SPC150 Self-Priming / Stainless Steel Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions

AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Simply unpack the pump and motor and examine for any

More information

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation. MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-Z PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL

More information

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information

More information

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS TO OBTAIN THE BEST PERFORMANCE FROM YOUR PROMAG SR PUMP, PLEASE READ THE MANUAL CAREFULLY. Failure to

More information

Operating Instructions

Operating Instructions Translation of the original instructions ONF 16 S / ONF 25 S Oil Mist Filter Operating Instructions PD 0057 BEN/C (1301) EN Table of contents Table of contents 1 About this manual...............................................

More information

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe

More information

1750 RPM Centrifugal Pumps

1750 RPM Centrifugal Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information

More information

ECONOMIZER FAN. Receiving and Inspection

ECONOMIZER FAN. Receiving and Inspection ECONOMIZER FAN Economizer Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for standard units of the Economizer Fan

More information

Instructions for installation, operation and maintenance of: SWING CHECK VALVE CSEN CSBS CAPS CSWEN CSWAPI. TERMOVENT SC Temerin Republic of Serbia

Instructions for installation, operation and maintenance of: SWING CHECK VALVE CSEN CSBS CAPS CSWEN CSWAPI. TERMOVENT SC Temerin Republic of Serbia Instructions for installation, operation and maintenance of: SWING CHECK VALVE CSEN CSBS CAPS CSWEN CSWAPI TERMOVENT SC Temerin Republic of Serbia Table of Contents 1. General safety information s... 3

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps 3200 Series Operating Manual Contents: Model Number/Serial Number/Safety Information Pg. 1 Safety Information (Con

More information

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

More information

S3 General Installation

S3 General Installation Wilfley Drylock Assembly General Installation Operating & General Servicing Clearance Settings Safety Precautions Spare Parts Ordering Assembly Instructions Model S3 General Installation Inspection upon

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : BANTAM C8 PART NO. : 602-325P SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@ PAGE - 1 - WARRANTY

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: These instructions are provided to familiarize the user with the seal and its use. The instructions must be read carefully

More information

Spare Parts List Return line filter RF

Spare Parts List Return line filter RF Spare Parts List Return line filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

End Suction Centrifugal

End Suction Centrifugal M o d e l s 3 U / 3 U B End Suction Centrifugal Operating Instructions, Installation & Maintenance Manual Certified to NSF/ANSI 6, ANNEX G * NSF/ANSI 6 Annex G listed models: 3U EBARA International Corporation

More information

Monocellular centrifugal electro-pumps

Monocellular centrifugal electro-pumps Réf. 2100 - O33 / a - 5.95 This manual must be given to the end user LS Monocellular centrifugal electro-pumps Installation and maintenance 1 - GENERAL The LS range of monobloc electro-pump units should

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

GT-200 GATE VALVES PN16, Screwed end

GT-200 GATE VALVES PN16, Screwed end Document No. : MD-QO-04-281 Date : 2009/07 /17 Version : 1.0 GT-200 GATE VALVES PN16, Screwed end USER MANUAL Modentic Industrial Corporation 14F-1,No.57Taya Rd.,Taichung,Taiwan,R.O.C. Email:modentic@ms9.hinet.net

More information

1329R Small AC Motors

1329R Small AC Motors Installation and Operation Manual 1329R Small AC Motors 1/3 through 3 HP 56-W180T 2 1329R Small AC Motors Installation and Operation Unpacking Unpack motor carefully and inspect for possible damage during

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: december 12, 2016 Supersedes: 40.80 Date: july 27, 2016 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

DulcoFlex Peristaltic Pump: DFB13B

DulcoFlex Peristaltic Pump: DFB13B INSTRUCTION MANUAL DulcoFlex Peristaltic Pump: This manual forms an integral part of the pump and must accompany it until its demolition. The peristaltic pump is a machine destined to work in industrial

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

JABSCO & Series 1½ 80 SIZE UTILITY Pump

JABSCO & Series 1½ 80 SIZE UTILITY Pump DOC271/98/01 Installation, Operating, Maintenance & Safety Instructions for JABSCO 53080 & 53081-Series 1½ 80 SIZE UTILITY Pump TO OBTAIN THE BEST PERFORMANCE FROM YOUR JABSCO PUMP PLEASE READ THESE INSTRUCTIONS

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

3.25 Ton Heavy Duty Floor Jack

3.25 Ton Heavy Duty Floor Jack Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL LATERAL TURNOVER 360 ORIGINAL INSTRUCTIONS INTRODUCTION This manual includes instructions for assembly, maintenance (regular and extraordinary), and for possible faults with remedies. The instructions

More information

Submersible Pump Instructions. Safety Instructions

Submersible Pump Instructions. Safety Instructions Submersible Pump Instructions Safety Instructions Before operating of this pump, read this manual and follow all safety rules and operating instructions. Before operating of this pump, read this manual

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: G-H, G-HL, G-K, G-KK, G-L, G-LQ, G-LL, GLS, G-Q, G-QS 1 Contents Maintenance Thrust bearing adjustment

More information

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user Réf. 3483 GB - 4.33/a - 09.2001 This manual is to be given to the end user PV4 - PIV6 Submersible multistage centrifugal Installation and maintenance PV4 - PIV6 1 - GENERAL PV4 and PIV6 series should be

More information

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps CD SERIES 1-3 HP @ 3450 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a

More information

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT 20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT PART NO: 7614058 OPERATION & MAINTENANCE INSTRUCTIONS WARNING: Read these instructions before using the press GC0516 INTRODUCTION Thank you for purchasing this

More information

Full View Flow Indicator

Full View Flow Indicator Full View Flow Indicator Threaded and Flanged Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com

More information

JET METER INSTRUCTIONS

JET METER INSTRUCTIONS UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : BANTAM C8 BANTAM C10 PART NO. : 602-325A 602-343A SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@

More information

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL

PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL PF SERIES PUMPS PFS ATEX VERSION (INCLUDES M6A, M6XA, M10X MOTORS & SPK) OPERATION & PARTS MANUAL Introduction This manual pertains to the PF Series, specifically the ATEX version of the PFS stainless

More information

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD VERTICAL CANTILEVER SHAFT SUMP PUMP (PPCS)_ METALLIC INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROCESS PUMPS (INDIA) PVT LTD Plot No.86, III Phase, Peenya Industrial Area, Bangalore 560058 Phone:

More information

Operations Manual. and. Seal Kit Replacement Guide

Operations Manual. and. Seal Kit Replacement Guide Operations Manual and Seal Kit Replacement Guide MANUFACTURED BY COLUSSI ENGINEERING PTY. LTD. TELEPHONE: (02) 9817 5433 FAX: (02) 9879 6753 53 College street, Gladesville, NSW 2111, Australia www.novapumps.com.au

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF Forged Strainers [SAP] Table of Contents 1.General safety information s 3 2. Product description 3 3. Transport and storage 5 4. Installation

More information

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS ROTARY VANE -00% OIL-FREE VACUUM PUMP OR COMPRESSOR 0 to 08 0 to 0 3060 to 3080 C CE RoHS ISO 9000:00 300 to 30 Read through carefully and understand these

More information

Operation Manual BOTTLE TOP DISPENSER

Operation Manual BOTTLE TOP DISPENSER Operation Manual BOTTLE TOP DISPENSER TABLE OF CONTENTS Page No. Intended Use Of The Instrument 1 Safety Instructions 1 Functions and Limitations of Use 2 Operating Exclusions 3 Storage Conditions 3 Chemical

More information

Operating instructions Form no safety definitions

Operating instructions Form no safety definitions Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge