DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit

Size: px
Start display at page:

Download "DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit"

Transcription

1 Volition VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. VF-45 Socket Termination Kit Get your hands on a Volition VF-45 Socket Termination Kit from 3M and you will have everything you need to quickly and easily install Volition VF-45 sockets onto duplex fiber optic cable. Cable and fiber strippers, polishing and socket assembly fixtures, and inspection viewer all fit in a micro pouch that can be clipped onto a tech s belt. The termination kit works in concert with the snap together design of the socket to eliminate most of the steps and labor associated with traditional fiber optic terminations. With the VF-45 socket termination kit, you can complete fiber installations faster and easier; duplex fiber terminations can be performed in less than two minutes. CLEAN UP YOUR ACT. Maintenance Cleaning Kit The Volition Maintenance Cleaning Kit from 3M keeps VF-45 fiber interconnects located within wall boxes, patch panels or electronic equipment, clean and operating at a just installed optical performance level. The system consists of a spray bottle of Volition HFE-Based Cleaning Fluid designed for cleaning VF-45 sockets and plugs. HFE-based cleaning fluid is non-flammable and non-conductive. The maintenance cleaning kit is a convenient, effective and quick way to clean fiber end faces, without disassembly from face plates or panels.

2 Volition VF-45 Socket Termination Kit FEATURES BENEFITS Simplified process Belt-loop micro pouch Faster and easier to use Easy to carry and easy to use Specifications Cool tool design Integrated process and higher reliability with fewer steps 500 terminations of the VF-45 socket per consumables are included in the kit. Individual replacement consumables and hand tools are available. 99% Isopropyl Alcohol purchased separately. Storage temperature: -40 to 60 C (-40 to 140 F) The hand tools included in the kit are used to prepare Volition optical fiber cable. Preparation of Volition Horizontal and Backbone Cable includes the stripping of duplex fibers for termination with VF-45 sockets (3M VOL-0001). Simultaneous duplex termination saves labor and speeds installation. The Polishing Puck Assembly, Polishing Station Base, and Lapping Film provide for fiber end face preparation to the specified length and finish for termination with VF-45 sockets (3M VOL-0001). The Swabs and Wipes are used for cleaning, while the View Scope is used for inspection of the optical fibers following the termination process, ensuring a high yield of VF-45 terminations for high performance. Installation Notes When planning large installations, calculate 500 terminations of the VF-45 socket per package of : Lapping Film 25 Discs Cotton Swabs 100 Discs Lint Free Wipes 100 Discs The Puck Polishing Face will wear slightly or may become clogged over hundreds of terminations, and is replaceable when needed. The Scribe Blade Assembly will wear with use. Typical blade life is 1,000 terminations. The blade edge may wear prematurely due to harsh handling or stressful conditions. The Scribe Blade Assembly is replaceable when needed. Instruction Manual (replacement folder) Part #

3 Ordering Information Model # VOL-0560 Description VF-45 Socket Termination Kit with Spiral Bound Instruction Manual Replacement Included in Model # Individual Components Quantity Kit VOL-0560 VOL-0560A Cable Jacket Stripper 1 * VOL-0560B Snips 1 * VOL-0560C Buffer Tube Stripper 1 * VOL-0560D Dual Fiber Stripper, 250 µm coating 1 * VOL-0560F Polishing Puck Assembly (includes Puck Polishing Face) 1 * VOL-0560G Puck Polishing Face 1 VOL-0560H Polishing Station Base (includes Scribe Blade Assembly and Foam Polishing Pad) 1 * VOL-0560J Scribe Blade Assembly 1 VOL-0560K Lapping Film 25 discs * VOL-0560L Fiber View Scope w/adapter Base (includes Penlight w/batteries) 1 * VOL-0560M Penlight (batteries included) 1 VOL-0560N Cotton Swabs 100 * VOL-0560P Lint Free Wipes 100 * VOL-0560R Bottle, Alcohol, empty 1 * VOL-0560S Carrying Case 1 * VOL-0560T Foam Polishing Pad 1

4 Volition Maintenance Cleaning System FEATURES BENEFITS Kit Contents Volition VF-45 Maintenance Cleaning Kit 1-16 oz. bottle, Volition HFE-Based Cleaning Fluid 1 - Spray nozzle, trigger activation with socket spray head 1 - VF-45 plug adapter Volition HFE-Based Cleaning Fluid 16 oz. bottle, replacement for Maintenance Cleaning Kit 12 bottles per case Specifications Non-flammable Non-conductive Low toxicity Rapid drying Front access spray cleaning HFE-Based Cleaning Solution Replacement bottle of cleaning solution Allows for front-face cleaning of VF-45 socket, no disassembly from face plate required 400 cleanings per 16 oz. bottle Storage temperature -40 to 60 C (-40 to 140 F) 16 oz. bottle, replacements available Easy maintenance in tight spots, no disassembly of wall plates, reduced labor Non-flammable, Non-conductive Cost effective Warning Do not substitute any other cleaning fluid due to the unique properties of Volition HFE-Based Cleaning Fluid. Other fluids may damage sensitive electronic equipment and will not properly clean the VF-45 interconnect. VF-45 Socket Spray Head (installed) Socket spray head inserts into VF-45 socket (3M part VOL-0001) or compatible Volition component. Activation of the trigger sprayer delivers a high force stream of Volition HFE-Based Cleaning Fluid to achieve effective cleaning of terminated fiber end faces.

5 Specifications (Cont.) VF-45 Plug Adapter Plug adapter couples the socket spray head to a VF-45 plug terminated on a patch cord or compatible Volition component. Activation of the trigger sprayer delivers a high-force stream of Volition HFE-Based Cleaning Fluid to effectively clean fiber end faces. Ordering Information Model # VOL-0570 VOL-0570A 9.10 (231.14) Description VF-45 Maintenance Cleaning Kit Volition HFE-Based Cleaning Fluid, 16 oz. bottle.38 (9.91) Dimensions in. (cm) 2.90 (73.66) Volition VF-45 Maintenance Cleaning Kit.62 (15.74) VF-45 Socket Spray Head (installed).58 (14.73) 1.31 (33.27) VF-45 Plug Adapter (included).45 (11.43).61 (15.49)

6 Important Notice All statements, technical information, and recommendations related to Seller s products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. Any statements or recommendations of the Seller which are not contained in the Seller s current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of Seller. The statements contained herein are made in lieu of all warranties, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed. SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER S PRODUCTS. 3 Telecom Systems Division 6801 River Place Blvd. Austin, TX / FAX 512/ Volition, VF-45 and the dot wave symbol are trademarks of 3M. 40% Pre-consumer waste paper 10% Post-consumer waste paper

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation Volition VF-45 Quick Install Kit and Maintenance Cleaning Kit O b D s oc ol e um te en t COOL HAND TOOLS. VF-45 Quick Install kit Get your hands on a VF-45 Quick Install Kit from 3M and you will have everything

More information

Volition. Fiber Optic Cable. 3Innovation

Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm

More information

8400 Series Fiber Distribution System

8400 Series Fiber Distribution System 8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable

More information

QT-III Cold Shrink Silicone Rubber

QT-III Cold Shrink Silicone Rubber QT-III Cold Shrink Silicone Rubber 7600-T-3RJS Series 3/C Cabinet Termination Instructions Kit Contents: 3ÑSilicone Rubber Phase Re-jacketing Sleeve Assembly 3ÑCold Shrink Silicone Rubber Termination Assembly

More information

3 Reenterable Encapsulated PST Dome Closure

3 Reenterable Encapsulated PST Dome Closure 3 Reenterable Encapsulated PST Dome Closure Instructions July 1998 34-7037-1080-5-B 1 Contents: 1.0 General...3 2.0 Kit Contents...3 3.0 PST Closure Capacity...3 4.0 Cable Preparation...4 5.0 Bonding and

More information

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C 3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm Instructions October 2010 78-8140-1581-0-C Contents 1.0 Summary...3 2.0 Connector Preparation...4 3.0 Fiber Preparation...4 4.0 Fiber

More information

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions 3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions February 2008 78-8140-1581-0 Contents 1.0 Summary...3 2.0 Connector Preparation...4 3.0 Fiber Preparation...4 4.0 Fiber

More information

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS 3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS Instructions January 2009 78-8140-3691-5-A Contents 1.0 Summary...3 2.0 Connector Preparation...4 3.0 Fiber Preparation...4 4.0 Fiber

More information

Cable Ties. Data Sheet

Cable Ties. Data Sheet Cable Ties Data Sheet Product Description 3M Cable Ties are molded from 6/6 Nylon and are available in a variety of sizes, styles and colors including weather resistant black for outdoor use. Agency Listings

More information

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide 3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide Installing Tall Skirt on SVC and SVE cabinets Instructions July 2016 78-0015-3067-0 2 July 2016 78-0015-3067-0 Contents 1. General

More information

Cold Shrink QS T Trifurcating Transition Splice Kit

Cold Shrink QS T Trifurcating Transition Splice Kit Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2

More information

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Instructions for Shielded and Belted PILC Cable IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice UniShield Wire Shielded Longitudinally

More information

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm 3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm Instructions January 2009 78-8140-3696-4-A 3 Contents 1.0 Kit Contents... 3 2.0 3M No Polish LC Connector SM & MM 250/900 µm... 4 Safety Precautions

More information

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief) Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone

More information

CS Fiber Optic Splice Case. Instruction

CS Fiber Optic Splice Case. Instruction 3 2179-CS Fiber Optic Splice Case Instruction 2179-CS Fiber Optic Splice Case Description 1.0 General 1.1 The 3M 2179-CS Fiber Optic Splice Cases are closures that can be used in buried, underground, aerial,

More information

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN 3 Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class 350 kv BIL IEC 60840 72,5 kv Kit Contents: 1 Silicone Rubber Lug Seal Insulator

More information

3M Locator Plate

3M Locator Plate 3M Locator Plate 3443-113 Instructions for the Assembly of 3M Tripolarized Wiremount Sockets 1.0 General The 3M Locator Plate 3443-113 was designed to aid in the assembly of the 3M Mini Socket Connector.50

More information

3M Locator Plate

3M Locator Plate M Locator Plate 44-94 Instructions for the assembly of M Socket Connectors,.100" x.100" and.100" x.200" 1.0 General M Manual and Pneumatic Assembly Presses and accessory assembly equipment are recommended

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW) 3M Cold Shrink Skirted Termination Kit QT-III 7672-S-8-TS (RW) for Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325 kv BIL CAUTION Working around energized systems

More information

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) 3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) for Tape Over Wire and Wire Over Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN For Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350 kv BIL IEC 60840 72,5

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC For Tape Shield or Longitudinally Corrugated (LC) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 3M Cold Shrink QT-III Silicone Rubber Termination For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable 7673-S-8(S)-TOW/WOT Instructions IEEE Std. No. 48 Class 1 Termination 69 kv Class, 350

More information

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits QTII (X) Series Silicone Rubber Cold Shrink Termination Kits For MV Armored/Non-Armored Cables up to 36kV DATA SHEET Update: August 2006 1. Product Description The 3M QTII (X) Series are Silicone Rubber

More information

Data Sheet July For RoHS information, please visit

Data Sheet July For RoHS information, please visit Data Sheet July 2017 3M Cable Ties are molded from 6/6 nylon and are available in a variety of sizes and styles, including weather resistant black for outdoor use. Agency Approvals & Self Certifications

More information

Volition Fiber Optic Cable

Volition Fiber Optic Cable Volition Fiber Optic Cable The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125 µm single-mode fiber. The horizontal cable

More information

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun Model No. SP-33000 Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun - 1 - TABLE OF CONTENTS: 1. Description 2. Specification and Technical Data 3. Important Safety Instruction 4. Instructions for

More information

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination Instructions Quick Term II Silicone Rubber Termination IEEE Std. No. 48 1990 Class 1 Termination 46 kv Class 250 kv BIL ÁÁ ÁÁ Kit Contents 1 High-K, 8 Skirted Silicone Rubber Termination 1 4 Skirt Silicone

More information

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...

More information

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive 3 3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive Technical Bulletin October, 2009 Description 3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive incorporate several

More information

3 TM Cold Applied Barrier Boot System

3 TM Cold Applied Barrier Boot System M Technical Information : Barrier Boot TM Cold Applied Barrier Boot System For rated voltages 6.5/11(12) kv and 8.7/15(17.5) kv 92-EE 717-1 Product Description The Cold Applied Barrier Boot System consist

More information

3M Closure System 2-Type Cover (505)

3M Closure System 2-Type Cover (505) 3M Closure System 2-Type Cover (505) Installation Instructions May 2009 78-8140-1009-2-B Contents 1.0 3M Closure Kit 2-Type Contents...3 2.0 Cover Installation...4 3.0 Closure Re-entry...6 4.0 Accessories...9

More information

3M Ladder Kit 3M710/MS 2 -TMK-LK

3M Ladder Kit 3M710/MS 2 -TMK-LK 3M Ladder Kit 3M710/MS 2 -TMK-LK Instructions 1.0 Summary The 3M Ladder Kit 3M710/MS2-TMK-LK is intended for mounting a communication line splicing system to a fiberglass extension ladder. 2.0 Kit Contents

More information

Polywater Duct Sealant (FST-250) Instructions for Use

Polywater Duct Sealant (FST-250) Instructions for Use FST-kit contents: Foam Base Cartridge (in protective pouch) Mixing Nozzles (in protective pouch/kit bag) Positioning Rod Polywater Duct Sealant (FST-250) Instructions for Use Foam Strips Pair Protective

More information

Toro Sprayer Calibration Tool

Toro Sprayer Calibration Tool Commercial Products Toro Sprayer Calibration Tool User Guide & Installation Instructions Toro Sprayer Calibration Tool 1 Table of Contents Introduction... 2 Program Instructions... 4 Toro Software End

More information

Mega-Rail System Installation

Mega-Rail System Installation Installation Manual Mega-Rail System P/N 030767-MRS 2003-2007 DODGE CUMMINS Mega-Rail System Installation Installation Instructions GDP 03-07 Mega-Rail System P/N 030767-MRS PLEASE READ ALL INSTRUCTIONS

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

SLiC Aerial Closures

SLiC Aerial Closures 3 SLiC Aerial Closures 1 The 3M SLiC Closure is a singlepiece aerial closure easily installed in construction or maintenance situations. The one piece construction permits complete splice access after

More information

Technical Data 3M Petroleum Sorbents

Technical Data 3M Petroleum Sorbents Technical Data 3M Petroleum Sorbents Use For control of spills of hydrocarbons on water or land. 3M Petroleum Sorbents repel water and will float (as long as surfactants are not also present). Product

More information

3 980/980E Ionized Air Gun Instruction Manual

3 980/980E Ionized Air Gun Instruction Manual 3 980/980E Ionized Air Gun Instruction Manual Index Section Page 1. General Description... 3 2. Performance... 3 3. Power Requirements...3 4. Air Supply Requirements... 3 5. Installation...4 6. Assembling

More information

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series 3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series Data Sheet 1. Product Description 3M Cold Shrink Termination Kit QT-III 7672-S-8 Series contains one silicone rubber termination

More information

710 Splicing Rig. Instructions. January E

710 Splicing Rig. Instructions. January E 710 Splicing Rig Instructions January 2007 Table of Contents 1.0 General Statement...4 2.0 3M 710-UTK25A Splicing Rig and Field Maintenance Kit...4 3.0 Straight Splicing using the 3M 710 25-pair modules...6

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

3M Ionized Air Gun 980/980E. User s Guide

3M Ionized Air Gun 980/980E. User s Guide 3M Ionized Air Gun 980/980E User s Guide Index Section Page 1. General Description... 3 2. Performance... 3 3. Power Requirements... 3 4. Air Supply Requirements... 4 5. Installation... 4 6. Assembling

More information

GM Specification Annual Test Data

GM Specification Annual Test Data GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing

More information

3M Mechanical Shearbolt Connectors, QCI Series

3M Mechanical Shearbolt Connectors, QCI Series M Mechanical Shearbolt Connectors, QCI Series Data Sheet November 2011 Description Connector Contents M Mechanical Shearbolt Connectors, QCI Series are designed to cover a wide range of conductor sizes

More information

Assembly Instructions

Assembly Instructions TOOLS REQUIRED: _(2) 3/4 wrenches _7/16 wrench _3/8 wrench _5/16 allen wrench Display/work stand is for assembly procedure only. May be purchased separately. CONTENTS (PARTS & HARDWARE) _(1) Receiver tube

More information

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A Owner's Manual Please read this manual before using your inverter 1INTRODUCTION Thank you for choosing to purchase our inverters. Our power inverter series

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

Natural Fiber Planter Fountain

Natural Fiber Planter Fountain Natural iber Planter ountain REMINDER CALL 1-888-755-5641 BEORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service department

More information

GM Specification Annual Test Data

GM Specification Annual Test Data GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing

More information

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array 3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array 1.0 mm Pitch Socket Platforms Socket Max. Package Maximum Max. Pin Lid Series Product Number

More information

3M Abrasive Systems Random Orbital Abrasive Disc Portfolio. Sanding & Finishing. Solutions. see inside. Distributed by:

3M Abrasive Systems Random Orbital Abrasive Disc Portfolio. Sanding & Finishing. Solutions. see inside. Distributed by: 3M Abrasive Systems Random Orbital Abrasive Disc Portfolio Sanding & Finishing Solutions! cs NsEivW e Dis Abra see inside Distributed by: The 3M Value The RIGHT Abrasives NEW Products NEW! Look for this

More information

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for 50 and 62.5 µm GiHCS, 200 µm HCS LC Connectors For Use With: 50 and 62.5 µm GiHCS 2.2 mm Fiber Optic Cables 200 µm HCS 2.2

More information

DODGE CUMMINS Air-Boss CR Intake Plenum

DODGE CUMMINS Air-Boss CR Intake Plenum Installation Manual P/N 0307-ABIP 2003-07 DODGE CUMMINS Air-Boss CR Intake Plenum Installation Instructions P/N 0307-ABIP GDP Air-Boss CR Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING

More information

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Instructions Kit Contents 3 Lug Covers 3 Cold Shrink Terminations 12

More information

3 740 Wrist strap + shoe tester

3 740 Wrist strap + shoe tester 3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too

More information

3M Cable Ties Product Guide. Made in USA. & Plenum Rated

3M Cable Ties Product Guide. Made in USA. & Plenum Rated 3M Cable Ties Product Guide Made in USA & Plenum Rated A new line of general use cable ties from 3M Made in USA These ties are made of high quality 6/6 nylon in the USA, which offers excellent availability

More information

Air-Boss VP Intake Plenum

Air-Boss VP Intake Plenum Installation Manual P/N 98502-ABIP 98.5-02 DODGE CUMMINS Air-Boss VP Intake Plenum Installation Instructions P/N 98502-ABIP GDP Air-Boss VP Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING

More information

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Single Lever Vessel Faucet Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories

More information

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC (MDR) Assembly Supports LVDS Channel Link signaling 20 shielded pairs (100 ohm) +4 drains for high bandwidth applications High density 50 position MDR with rugged ribbon type contact 3 Unshielded Twisted

More information

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series 3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series Data Sheet March 2011 Description 3M Cold Shrink 1/C Transition Splice Kits QS-III, 5510A-1T-PILC Series (which includes 5513A-1T-PILC,

More information

DODGE CUMMINS MK-2 Micro-Kleen System

DODGE CUMMINS MK-2 Micro-Kleen System Installation Manual P/N MK20306 2003-07 DODGE CUMMINS MK-2 Micro-Kleen System Installation Instructions P/N MK20306 2 Micron Fuel Filter Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

More information

Installation Instructions Soft Top Replacement Hardware, Wrangler

Installation Instructions Soft Top Replacement Hardware, Wrangler Installation Instructions Soft Top Replacement Hardware, 87-95 Wrangler IMPORTANT NOTICE: Carefully read instructions before attempting to install this product. Rampage is in no way responsible for any

More information

Container Fountain Kit with LED Light

Container Fountain Kit with LED Light Container Fountain Kit with LED Light REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service

More information

Door Edge Protection Film 36 inch

Door Edge Protection Film 36 inch Door Edge Protection Film 36 inch Technical Data Sheet June, 2013 3M Part No.(s) PN 3M Part Descriptor(s) Door Edge Protection Film 36 inch Product Description 3M Door Protection Film is a super tough

More information

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms 3M Products for Electrical Networks Wind Farm Capabilities Leading Edge Electrical Solutions for Wind Farms 3M technologies for wind farms Wind farm projects are difficult enough without the risk of construction

More information

Integrated Heating System

Integrated Heating System Integrated Heating System Model 5474 Model 5474A Model 5474L Operating Manual 7/05/06 www.electrotechsystems.com TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION 1 2.0 INSTALLATION 2 2.1 Mechanical Installation

More information

Mechanical Filter Pump Kit Up to 500 gallons

Mechanical Filter Pump Kit Up to 500 gallons Mechanical Filter Pump Kit Up to 500 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FM002P Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction FIST-FPS I N S T A L L A T I O N I N S T R U C T I O N Front Patching Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Side cable termination directly on

More information

Electrostatic Fieldmeter

Electrostatic Fieldmeter Electrostatic Fieldmeter Operation Manual Model 521AE Contents Precautions 1 3. Technical Specifications 4 1. Features and Descriptions 1-1. Features 1-2. Descriptions 2 4. Dimensions 5. Warranty 4 5 2.

More information

19 1HU Splicing and Front Patching Shelf

19 1HU Splicing and Front Patching Shelf FOMS-FPS-O-XXXX-XX I N S T A L L A T I O N I N S T R U C T I O N 19 1HU Splicing and Front Patching Shelf Contents 1 Introduction 2 General 2.1 Characteristics 2.2 Kit contents 2.3 Tools 3 Installation

More information

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary 3M Electrical Tapes Product Selection Guide Insulate & Protect with Quality Tapes Get your hands on 3M Tape! 3M now offers new and experienced electricians a chance to sharpen their skills with the complete

More information

Customer Support

Customer Support Portable auxiliary air tanks owner's Manual aux05 aux05a aux10 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon Important Safety InStructIonS components

More information

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks - 1 - PMD DRIVER RELOCATION KIT For 1994-1999 Chevy 6.5L Diesel Trucks Part# 1036520 -- Installation Instructions -- PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. - 2 - Kit Contents BD P/N#

More information

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650023EN Effective October 2016 Supersedes March 2012 (IS550-60-1) COOPER POWER SERIES DTS1242 Deadbreak Bolted Tee Connector: Interface C for Single Core Cable with Copper

More information

External Non-Contact Fluid Level Sensor

External Non-Contact Fluid Level Sensor External Non-Contact Fluid Level Sensor NON-CONTACT SENSOR Tek Tanks Limited The Old Stables Tel: +44 (0)1420 520830 West End Farm Fax:+44 (0)1420 520840 Upper Froyle sales@tek-tanks.com Hampshire GU34

More information

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 5/8.7 kv Class 95 kv BIL Kit Contents: 3 Hi K, Tracking Resistant,

More information

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves

More information

77/177 & 76/176 Hubs. service manual. GEN Rev C 2017 SRAM, LLC

77/177 & 76/176 Hubs. service manual. GEN Rev C 2017 SRAM, LLC 77/177 & 76/176 Hubs service manual GEN.0000000004927 Rev C 2017 SRAM, LLC SRAM LLC WARRANTY EXTENT OF LIMITED WARRANTY Except as otherwise set forth herein, SRAM warrants its products to be free from

More information

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - 29 September 2005 Dodge Cummins Low Fuel Pressure Alarm Light Kit 1081130-33 1 1999-2005 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130 Red 1081133

More information

Female Plug. connecting to Fuel Quantity

Female Plug. connecting to Fuel Quantity **Ag Diesel Solutions recommends replacing the Transorb/Suppressor Diode before the installation of this module*** Red wire = 12V Constant power. Male Plug connecting to Fuel Quantity Valve Black wire

More information

3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity.

3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity. 3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity. Better. To help make you better. As a painter, you take great pride in your work. You know that the ultimate quality of the

More information

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS ) Screened Separable Connectors MN650024EN Effective October 2016 Supersedes March 2012 (IS550-61-1) COOPER POWER SERIES DTB1242 Deadbreak Bolted Companion Tee Connector: Interface C for Single Core Cable

More information

Mechanical Filter Box Kit

Mechanical Filter Box Kit Mechanical Filter Box Kit REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. MODEL #MFBX500P Questions, problems, missing parts? Before returning to your retailer, call our customer service department

More information

Cognition TM. Hubs Service Manual. GEN Rev B 2017 SRAM, LLC

Cognition TM. Hubs Service Manual. GEN Rev B 2017 SRAM, LLC Cognition TM Hubs Service Manual GEN.0000000005069 Rev B 2017 SRAM, LLC SRAM LLC WARRANTY EXTENT OF LIMITED WARRANTY Except as otherwise set forth herein, SRAM warrants its products to be free from defects

More information

72 in / 1,83 m SWIVEL TABLE

72 in / 1,83 m SWIVEL TABLE ITEM# 1-1-37001 72 in / 1,83 m SWIVEL TABLE 4 Great Games in 1-4 gran opciones de juego Assembly Instructions Model # 37001 www.eastpointsports.com TWO OR MORE ADULTS REQUIRED FOR ASSEMBLY IMPORTANT SAFETY

More information

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS Bridge W/D's Panel Part # Page No. Nema-4/12 1-Speed 444231-** 2 Nema-4/12 1-Speed with Soft-Start 444711-** 3 Nema-4/12 2-Speed 444232-** 4 Nema-4/12 2-Speed

More information

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS 9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS NG1205 / NG1210 / NG1212 / NG1214 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure

More information

ATN3580 Series: Fixed Attenuator Pads

ATN3580 Series: Fixed Attenuator Pads DATA SHEET ATN3580 Series: Fixed Attenuator Pads Applications Attenuators Features Specified flat response to 40 GHz Return loss > 15 db Available at 1-10, 12, 15, 20, 30, and 40 db Power handling to 1

More information

Finish Line. Redefining The. NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders

Finish Line. Redefining The. NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders Redefining The Finish Line 3M Elite Series Sanders NEW Elite Series Air-Powered Sanders and NEW Electric

More information

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS Please Do Not Hesitate to Contact Our Consumer Hotline at 800-759-0977 with Any Questions That May Arise During Assembly or Use of This Product! NG2336P

More information

3M Automotive Aftermarket. 3M Blue Abrasives. The upgrade you ve been waiting for.

3M Automotive Aftermarket. 3M Blue Abrasives. The upgrade you ve been waiting for. 3M Automotive Aftermarket 3M Blue Abrasives. The upgrade you ve been waiting for. 3M Stikit Blue Abrasive Disc 3M Blue Abrasives are your go-to workhorse for the entire shop. 5" 3M Hookit Blue Abrasive

More information

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 29 July 2005 2003-04.5 Dodge Cummins OEM Bypass Lift Pump Kit # 1050227-1 - 2003-04½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050227 PLEASE READ ALL INSTRUCTIONS CAREFULLY

More information

Bosch Smart Home. Door/Window Contact Instruction Manual

Bosch Smart Home. Door/Window Contact Instruction Manual Bosch Smart Home Door/Window Contact Instruction Manual Start making your home smart! Please be sure to install the Bosch Smart Home Controller first. Please ensure that you have a Bosch Smart Home Controller

More information

Series Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017

Series Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017 Traffic Safety and Security Division 3M Diamond Grade TM DG 3 Reflective Sheeting Series 4000 Product Bulletin Series 4000ESV 06/2017 1 Description 3M TM Diamond Grade TM DG 3 Reflective Sheeting Series

More information

Illumifalls Patio Pond

Illumifalls Patio Pond Illumifalls Patio Pond REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-755-4497,

More information

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE. Complete Pond Kit REMINDER CA 1-888-755-4497 BEFORE RETURNING TO STORE. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-755-4497, 8

More information