PRODUCT CATALOGUE CHILLER ECOMAX

Size: px
Start display at page:

Download "PRODUCT CATALOGUE CHILLER ECOMAX"

Transcription

1 PRODUCT CATALOGUE CHILLER ECOMAX English/

2 AIR COOLED CHILLER INTRODUCTION TO THE RANGE The simple and robust design of the Ecomax range brings real benefits in terms of savings in investment, operation and maintenance. To meet the requirements of every application, the Ecomax range is available in : (Reciprocating compressors, only available in High Ambient) 3 versions : Standard (STD) : economical Complete unit, ready for use, benefiting from Lennox design and manufacturing quality High Ambient (HA) : severe environment High-Efficiency condenser fans, ventilated control panel with resistance heater to prevent condensation Low Noise (LN) : low sound level Low-speed condenser fan, oversized condenser coils and sound insulation cabinet for compressors. 6 db reduction in sound power LCH V / P kw CONSTRUCTION Machine welded framework for enhanced rigidity Aluzinc sheet casing Protection by Epoxy treatment (RAL 9002) Semi-sealed piston compressor, part-winding starting (LCH P) Semi-sealed screw compressor, part-winding starting (LCH V) R407C refrigerant Multitube dry expansion evaporator - 13 mm close cell foam insulation Vertical condenser coils (reduced clogging - easy cleaning) High efficiency condenser fan with low noise level IP55 class F motor Control and protection panel according to EN , 3 and 4 independent cooling circuits according to size Filter dryer, liquid indicator, thermostatic expansion valve, HP pressure switches, manual valve on each compressor discharge HP and LP electronic pressure sensors CLIMATIC TM 50 electronic controller PN 16 flanged water connection CLIMATIC TM CONTROL PID control CLIMATIC : Start/stop programming - Set point change Compressor operating time balancing Set point adjustment according to external temperature Fault control for each component General alarm with report Antifreeze protection Control of one or more pumps Connectable to a BMS Digital screen Non contractual photos 2

3 GENERAL DATA - SCREW COMPRESSORS - STD VERSION ECOMAX STD LCH V Cooling capacity (1) kw Power Input (1) kw COP (2) 2,7 2,6 2,7 2,6 2,7 2,5 2,7 2,4 2,4 2,7 Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb Capacity steps % Refrigerant charge per circuit kg 64/49 64/ /64 83/ Type DN 150 DN 150 DN 150 DN 150 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 Diameter 1/2» 1/2» 1/2» 1/2» 1/2» 1/2» 1/2» 1/2» 1/2» 1/2» Number Nb Nominal air flow m 3 /h Total motor power input kw 11,9 11,9 13,6 13,6 15,3 15, ,4 20,4 Fan speed rpm Sound pressure level (2) db(a) Maxi. outside air temperature C 49,5 49,5 49,5 49,5 48,5 48,5 48,5 48, Maxi. inlet water temperature C 20 ECOMAX STD LCH V Cooling capacity (1) kw Power Input (1) kw COP (2) 2,7 2,6 2,8 2,5 2,7 2,6 2,7 2,4 2,5 2,4 Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb Capacity steps % Refrigerant charge per circuit kg 98/64 98/64 83/98 83/98 83/98 83/ Type Flanges - PN 16 Diameter DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 Number Nb Nominal air flow m 3 /h Total motor power input kw 23,8 23,8 27,2 27,2 27,2 27, Fan speed rpm Sound pressure level (2) db(a) Maxi. outside air temperature C ,5 48,5 47,5 47,5 48,5 48,5 47,5 47,5 Maxi. inlet water temperature C 20 (1) Water : 12 C/ 7 C - Air : 35 C (2) EUROVENT conditions 3

4 ecomax GENERAL DATA - SCREW AND RECIPROCTING COMPRESSORS - HA VERSION Reciprocating compressor Screw compressor ECOMAX HA LCH P/V Cooling capacity (1) kw Power Input (1) kw COP (2) 3,3 3,1 3,3 3,0 3,1 3,0 3,1 3,0 3,0 2,8 3,1 2,8 400V/III/50Hz Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb DX Shell and tubes Capacity steps % Refrigerant charge per circuit kg 65 86/ /65 86/ /86111/ Type DN150DN200 DN200 DN200 Diameter 1/2» 1/2» 1/2» 1/2» DN 150 DN 150DN 150 DN 150 DN 200DN 200 DN 200DN 200 Number Nb Nominal air flow m 3 /h Total motor power input kw 19,8 19,8 26,4 26,4 23,1 23,1 26,4 26,4 29,7 29, Fan speed rpm Sound pressure level (2) db(a) Maxi. outside air temperature C , Maxi. inlet water temperature C Screw compressor ECOMAX HA LCH V Cooling capacity (1) kw Power Input (1) kw COP (2) 3,2 3,1 2,7 2,6 2,7 2,5 2,7 2,6 2,7 2,5 2,6 2,5 Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb Capacity steps % Refrigerant charge per circuit kg /86 131/86 111/ / / / Type DX Flanges - PN 16 Diameter DN200 DN 200 DN 200 DN 200DN 200DN 200 DN 200 DN 200 DN 200DN 200 DN 200 DN 200 Number Nb Nominal air flow m 3 /h Total motor power input kw 39,6 39,6 46,2 46,2 52,8 52,8 52,8 52, Fan speed rpm 950 Sound pressure level (2) db(a) Maxi. outside air temperature C 52,5 52,5 52,5 52, ,5 51, ,5 51,5 Maxi. inlet water temperature C 20 (1) Water : 12 C/ 7 C - Air : 35 C (2) EUROVENT conditions 4

5 GENERAL DATA - SCREW COMPRESSORS - LN VERSION ECOMAX LN LCH V Cooling capacity (1) kw Power Input (1) kw COP (2) 3,1 3,0 3,1 3,0 3,1 2,9 3,1 2,8 3,2 3,1 Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb Capacity steps % Refrigerant charge per circuit kg 86/65 86/ /86 111/ Type Flanges - PN 16 Diameter DN 150 DN 150 DN 150 DN 150 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 Number Nb Nominal air flow m 3 /h Total motor power input kw 8,4 8,4 9,6 9,6 10,8 10, ,4 14,4 Fan speed tr/mn Sound pressure level (2) db(a) Maxi. outside air temperature C ,5 50,5 50,5 50,5 50,5 50,5 Maxi. inlet water temperature C 20 ECOMAX LN LCH V Cooling capacity (1) kw Power Input (1) kw COP (2) 3,0 2,9 3,1 2,8 2,9 2,8 3,0 2,7 2,8 2,7 Start-up intensity (Part-winding) A Maximum current A Number of circuits Nb Compressor Nb Capacity steps % Refrigerant charge per circuit kg 131/86 131/86 111/ / / / Type Flanges - PN 16 Diameter DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 Number Nb Nominal air flow m 3 /h Total motor power input kw 16,8 16,8 19,2 19,2 19,2 19, Fan speed tr/mn 550 Sound pressure level (2) db(a) Maxi. outside air temperature C 50,5 50,5 50,5 50, ,5 50, Maximum inlet water temperature C 20 Minimum outlet water temperature C +5 C and -10 C with 30% glycol (1) Water : 12 C/ 7 C - Air : 35 C (2) EUROVENT conditions 5

6 ecomax PHYSICAL DATA 1 C B A ECOMAX - Screw compressors LCH V STD version A mm C mm Weight without water kg Operating weight kg HA version A mm C mm Weight without water kg Operating weight kg LN version A mm C mm Weight without water kg Operating weight kg ECOMAX - Screw compressors LCH V STD version A mm C mm Weight without water kg Operating weight kg HA version A mm C mm Weight without water kg Operating weight kg LN version A mm C mm Weight without water kg Operating weight kg

7 2 C B A ECOMAX - Reciprocating compressors LCH P HA version A mm B mm C mm ,5 2263,5 Weight without water kg Operating weight kg OPTIONS Anti intrusion Guards Antifreeze protection Anti-vibration mounts rubber Anti-vibration mounts spring BLYGOLD PLUS Coils treated Coils protection Guards Control panel Anti-condensation heaters Cu / Cu Condenser coils Electronic Expansion valve Embellished posts Epoxy Coated Condenser fins Flow switch (a paddle) Flow switch (pressure drop control) HP&LP pressure gauges HP&LP pressure gauges and oil DC 50 Comfort Display DS 50 Service Display Low Ambient kit Main ON/OFF switch Mod-Bus interface Power Factor Correction R22 Reinforced evaporator insulation Soft Starter Suction isolation Valve UDT standard conformity Water filter Water inlet/outlet valves Water inlet/outlet manometer Electrical meter 1 extra step control 7

8 BELGIUM, LUXEMBOURG : LENNOX BENELUX N.V./S.A. CZECH REPUBLIC : LENNOX JANKA a.s. FRANCE : LENNOX FRANCE GERMANY : LENNOX DEUTSCHLAND GmbH NETHERLANDS : LENNOX BENELUX B.V. POLAND : LENNOX POLSKA Sp. z o. o. PORTUGAL : LENNOX PORTUGAL Lda. RUSSIA : LENNOX DISTRIBUTION MOSCOW SLOVAKIA : LENNOX SLOVENSKO s.r.o. SPAIN : LENNOX REFAC S.A. UKRAINE : LENNOX DISTRIBUTION KIEV UNITED KINGDOM, IRELAND : LENNOX INDUSTRIES Ltd OTHER EUROPEAN COUNTRIES, AFRICA, MIDDLE-EAST : LENNOX DISTRIBUTION ECOMAX-PCA-0205-E Due to Lennox's ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency.

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC English/09-2003 CHILLED WATER CASSETTE! INTRODUCTION TO THE RANGE The units are available in the following versions:! 2 pipes! 2 pipes - 2 wires (electrical

More information

application guide axial condensing units

application guide axial condensing units application guide axial condensing units 17 English/07-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectations WARNING: Read this manual before installation,

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw Chiller AQSL 2612 to 4212 Air Cooled Chillers With or without total heat recovery Engineering Data Manual 602 to 908 kw Features & Strength Points Sturdy structure, vibration tests and FEM structural analysis.

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

CWP-CO / CWP-RC / CWP-HP 02 to 35

CWP-CO / CWP-RC / CWP-HP 02 to 35 Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

VHA. Air cooled chiller with

VHA. Air cooled chiller with TECHNICAL Data Sheet Air cooled chiller with SCROLL OR RECIPROCATING compressors and axial fans for outdoor installation V Range 19-1196 kw Range Air cooled chiller with scroll or reciprocating compressors

More information

Air Cooled Single Screw Chiller/ Heat Pump

Air Cooled Single Screw Chiller/ Heat Pump Technical Manual MHS - F - 2014 Air Cooled Single Screw Chiller/ Heat Pump Models: MCS050.1-380.2F MHS050.1-380.2F Cooling Capacity: 169kW-1370kW Heating Capacity: 179kW-1439kW Refrigerant: R22/R407C Engineered

More information

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension Air cooled Condensers New condenser generation with better performance Capacities 9-1060 kw Ripple Fin tubing Floating coil block suspension Eurovent certified Capacities based on ENV 327 voor R404A *DX

More information

AQWL/AQWH/AQWR 1404 to 2406

AQWL/AQWH/AQWR 1404 to 2406 Chiller AQWL/AQWH/AQWR 1404 to 2406 Air Cooled Water Chillers Only, Heat Pump and Total Heat Recovery Engineering Data Manual 380 to 634 kw 418 to 702 kw Features & Strength Points A more "slim and light"

More information

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw Water/water cooled chillers and heat pumps 172 1527 kw General information Water-cooled water chillers with hermetic screw compressors and tube bundle heat exchangers. Designed for installation indoors.

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

WQL/WQH/WQRC 524 to 1204

WQL/WQH/WQRC 524 to 1204 Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features

More information

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC) CHILLER START UP PROCEDURE FORM DOC. N 061103 (DOC.N 071103 BELOW TO BE RETURN TO AERMEC) 1. Preliminary Operation WARNING: The following operation must be done without the power supply (unit with the

More information

FSP Fan Speed Power Module Technical Data

FSP Fan Speed Power Module Technical Data PCN: 800 373 Q0337 Signal 0... 10V 230VAC 8A 230VAC 8A FSP Technical Data Electronic Power Modules FSP control the speed of condenser fan motors in commercial refrigeration and airconditioning systems.

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages Water-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com 30XW- 30XWH Nominal cooling capacity 275-1765 kw Nominal heating capacity 320-1875 kw The 30XW liquid chillers are the premium

More information

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw Water-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com 30XW- 30XWH Nominal cooling capacity 278-1756 Nominal heating capacity 322-1989 The 30XW liquid chillers are the premium solution

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

DXP 100 Air Cooled Condenser

DXP 100 Air Cooled Condenser Air Cooled Condenser Applied for CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene

More information

Application guide ECOLOGIC

Application guide ECOLOGIC Application guide ECOLOGIC Providing indoor climate comfort ECOLOGIC-AGU-0407-E TABLE OF CONTENTS APPLICATION GUIDE Ref : ECOLOGIC-AGU-0407-E 1. GENERAL DESCRIPTION 3 2. 3. 4. 5. FEATURES AND BENEFITS

More information

Aggressive Environments SERIES

Aggressive Environments SERIES Aggressive Environments SERIES The need to provide geared motors suitable for use in wet and corrosive environments has led Motovario to design a new product range specific for these fields. These products

More information

30HXC. Water-Cooled Screw-Compressor Liquid Chillers. Nominal cooling capacity kw. Features

30HXC. Water-Cooled Screw-Compressor Liquid Chillers. Nominal cooling capacity kw. Features Water-Cooled Screw-Compressor Liquid Chillers www.eurovent-certification.com www.certiflash.com 30HXC Nominal cooling capacity 286-1302 The 30HXC units are water-cooled chillers, designed from the ground

More information

Inverter air to water heat pumps

Inverter air to water heat pumps Product Manual 504 B 07/07 A EN Date: July 2007 Supersedes: none Inverter air to water heat pumps McEnergy HPI 067.2 104.2 Cooling capacity from 249 to 385 kw Heating capacity from 274 to 412 kw Refrigerant:

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS Dry Cooler CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene glycol mixture. The coolers

More information

Reversible air-to-water scroll heat pumps

Reversible air-to-water scroll heat pumps Reversible air-to-water scroll heat pumps Model CXAO 120 to 290 Cooling capacity: 420-1030 kw Heating capacity: 475-1175 kw CG-PRC027A-GB Table of Contents Model number description...4 Technical specifications...5

More information

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 Low Air Process Room Chiller Series EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

Residential power RSPW/GB-2008/1

Residential power RSPW/GB-2008/1 Residential power RSPW/GB-2008/1 SDMO : provides whatever power is required SDMO is recognised as one of the leading generator set manufacturers. SDMO has designed a range of competitive, high performance

More information

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw TM Chiller with integrated Free Cooling system chillers and heat pumps, 100-530 kw General The TEAL FC range, with scroll compressors and free cooling system, uses the ecofriendly R410A refrigerant and

More information

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design Airsock unit coolers THOR-A Standard coolers in a revolutionary design O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................ 2 Eurovent......................................

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC Cooling capacity: Heating capacity: 17,7 to 74,3 kw 21,8 to 84,8 kw Scroll compressors R-410A refrigerant Compact and silent design Cooling solution where an outdoor installation is impossible DESCRIPTION

More information

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 LOW AIR / DUAL THROW UNIT COOLER EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

Aggressive Environments

Aggressive Environments n Aggressive Environments e w The need to provide geared motors suitable for use in wet and corrosive environments has led Motovario to design a new product range specific for these fields. These products

More information

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK Air Cooled CHILLER CAPACITY: 25-206 TR 2 Company Business Awal Gulf Manufacturing, located at Bahrain is the one of the leading manufacturers of air conditioning and refrigeration products in Middle East

More information

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation Technical Data Contents 04/2018 01 Overview 02 ecoo 02 Cooling innovation 04 05 Overview Technical data 03 HybridChiller 04 Re-cooler 08 Overview 12 Overview 10 Technical data 13 Technical data 05 Circuit

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

ACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform...

ACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform... ACPSB-P Series Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R R407C Products that perform...by people who care NOMENCLATURE 6 AC P S B 435 P - Q P 6-60 Hz Blank - 50Hz Blank P - R - R407C

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES

More information

Dual discharge air coolers THOR-D. Standard coolers in a revolutionary design

Dual discharge air coolers THOR-D. Standard coolers in a revolutionary design Dual discharge air coolers THOR-D Standard coolers in a revolutionary design O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................ 2 Eurovent......................................

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

OIL FREE PISTON COMPRESSORS THE WORLD LEADER OF PET COMPRESSORS

OIL FREE PISTON COMPRESSORS THE WORLD LEADER OF PET COMPRESSORS AF COMPRESSORS OIL FREE PISTON COMPRESSORS THE WORLD LEADER OF PET COMPRESSORS WWW.AFCOMPRESSORS.COM INNOVATION AND TRADITION In compressed air industry since 1870 The leading company of high quality compressed

More information

DOUBLE OCTOMILL TM PRODUCT RANGE

DOUBLE OCTOMILL TM PRODUCT RANGE DOUBLE OCTOMILL TM PRODUCT RANGE Double Octomill insert selection and cutting data recommendations, see page 6. complete insert programme, see page 7. Tool angles: Jo = -11q Jp = - 8q Jf = - 8q Pitch

More information

... RTU Technical Manual. Packaged Air Conditioning Unit...

... RTU Technical Manual. Packaged Air Conditioning Unit... ... RTU Technical Manual Packaged Air Conditioning Unit... Index. CODING AND MODELS. WORKING LIMITS. TECHNICAL SPECIFICATIONS. PERFORMANCE TABLES. TECHNICAL SPECIFICATIONS FOR OPTIONAL EQUIPMENT. ELECTRONIC

More information

products 22 º C Ventilation Air Conditioning Refrigeration Self Contained Units - 90MA self-contained marine air conditioning unit Inside

products 22 º C Ventilation Air Conditioning Refrigeration Self Contained Units - 90MA self-contained marine air conditioning unit Inside products > Self Contained Units - 90MA self-contained marine air conditioning unit OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration

More information

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

YCUJ Millennium TM AIR COOLED CONDENSING UNIT YCUJ Millennium TM AIR COOLED CONDENSING UNIT REFRIGERANT R407C COOLING CAPACITIES 348 kw to 760 kw The YCUJ range of Condensing Units are designed for direct expansion cooling and are usually used in

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw Condensers NEOSTAR 18 kw 12 kw Friga-Bohn reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual www NEW! The air cooled condenser units of the new NEOSTAR

More information

Ultima Compact Air Cooled Liquid Chiller 30kW - 450kW

Ultima Compact Air Cooled Liquid Chiller 30kW - 450kW Ultima Compact Air Cooled Liquid Chiller 30kW - 450kW T E C H N I C A L M A N U A L Customer Services About Airedale Products & Customer Services WARRANTY, COMMISSIONING & MAINTENANCE The equipment carries

More information

MAKING REFRIGERATION GREENER

MAKING REFRIGERATION GREENER Searle KME air cooler MAKING RERIGERATION GREENER The Searle KME cooler range from Kelvion is ideally suited to large cold rooms and small warehouses where an efficient cooling solution is required. The

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

CXAM. Options. Accessories

CXAM. Options. Accessories CXAM Reversible air-to-water scroll heat pump Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Nominal Cooling Capacity Range R22: 139.5 kw 1825 kw 119,970kcal/h 1,569,500kcal/h 39.7 RT 519.1 RT R407C: 130 kw 1755 kw 111,800kcal/h

More information

30HXC. Water-Cooled Screw-Compressor Liquid Chillers PRO-DIALOG PRODUCT SELECTION DATA MAINTENANCE INSTRUCTIONS. Quality design and construction

30HXC. Water-Cooled Screw-Compressor Liquid Chillers PRO-DIALOG PRODUCT SELECTION DATA MAINTENANCE INSTRUCTIONS. Quality design and construction PRO-DIALOG PRODUCT SELECTION DATA Quality design and construction INSTALLATION, Very OPERATION compact dimensions AND MAINTENANCE INSTRUCTIONS for easy installation Two independent refrigerant circuits

More information

HGX6/ S Engine: V Y/YY -3-50Hz PW Refrigerant: R404A, R507

HGX6/ S Engine: V Y/YY -3-50Hz PW Refrigerant: R404A, R507 Performance data Application: Refrigeration & AC Refrigerant R404A, R507 Power supply 50 Hz, 400 V Supply frequency 50 Hz Evaporating temperature 5.0 C Evaporating pressure (abs.) 7.06 bar Condensing temperature

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

OMICRON V EVO. Multifunctional unit

OMICRON V EVO. Multifunctional unit Multifunctional unit 231 773 General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and semihermetic screw compressors. Production of hot water up to

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

D6.. Butterfly valves. For controlled operation.

D6.. Butterfly valves. For controlled operation. D6.. Butterfly valves. For controlled operation. Water is our element. www.belimo.eu Total solutions for medium and large volumetric flows. Butterfly valves from Belimo are available as classical D6..N

More information

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER Making refrigeration greener KELVION KME COMMERCIAL COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners worldwide More

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

30XA A Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

30XA A Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Unit with option 279 (compressor enclosure) 30XA A 252-1702 Nominal cooling capacity 267-1682 The Aquaforce liquid chillers

More information

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11 Index Features and advantages... 3 Low operating cost... 3 Low operating sound levels... 3 Excellent serviceability... 3 Proven reliability... 3 Infinite capacity control... 3 Superior control logic...

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information