1 SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece heat pump with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High-efficiency design with SEERs (Seasonal Energy Efficiency Ratios) of 13.0 and HSPFs (Heating Seasonal Performance Factors) of up to 7.7. Easy Installation Factory-assembled package is a compact, fully self-contained, heat pump unit that is pre-wired, pre-piped, and pre-charged for minimum installation expense. units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units install easily on a rooftop or at ground-level. Durable, dependable components Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Compressors have internal high-pressure and overcurrent protection. Direct-drive multi-speed, PSC (permanent split capacitor) blower motor is standard on all models. Direct-drive, PSC condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40 F outdoor temperature. Motormaster II low

2 ambient kit is available as a fieldinstalled accessory and does not require a special motor. Corporate thermostats work with Carrier s small packaged products as a system to promote year round comfort. Refrigerant system is designed to provide dependability. Liquid refrigerant strainers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. Low Pressure/Loss of Charge Switch assures added safety and reliability for the compressor. Indoor and outdoor coils are computer-designed for optimum heat transfer and cooling efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. A FIOP (Factory-Installed Option) metal louvered grille is available on all models. Copper fin coils and pre-coated fin coils are available from the factory by special order. These coils are recommended in applications where aluminum fins are likely to be damaged due to corrosion. They are ideal for seacoast applications. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72 db. (See page 3.) Easy to service cabinets provide easy single-panel accessibility to serviceable components during maintenance and installation. The unit base with integrated drain provides easy ground level installation with or without a mounting pad. Convenient handholds are provided to manipulate the unit on the jobsite. A nesting feature ensures a positive unit base to roof curb seal when the unit is roof mounted. A convenient 3/4-in. wide perimeter flange makes frame mounting on a rooftop easy. Downflow operation is easily provided in the field to allow vertical ductwork connections. The unit base utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode. Standard metal duct covers with insulation come with the unit and cover the duct openings. These can be left in place if the units are converted to downshot. Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours of salt spray. Interior surfaces are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain minimizes standing water in the drain, which is provided with an external drain fitting. Short-Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason. Table of contents Page Features/Benefits ,2 Model Number Nomenclature ARI Capacities Physical Data Options and Accessories ,6 Base Unit Dimensions ,8 Accessory Dimensions Selection Procedure Performance Data Typical Piping and Wiring Application Data Electrical Data ,22 Typical Wiring Schematics Controls Guide Specifications

3 Model number nomenclature AD Model No. Single Packaged Heat Pump Nominal Cooling Capacity (Tons) TT / / Options - - Wire Grille AD Louvered Grille Options BT Wire Grille and vinyl-coated (None) outdoor Wire Grille coil fin AD XT Louvered Grille Grille and vinyl-coated BT Wire outdoor Grille and coil fin Vinyl-Coated Condenser CC Coil Wire Fin Grille, AL indoor and CU/CU XT Louvered outdoor Grille coil and Vinyl-Coated Condenser Wire Coil Grille, FinCU/CU indoor and CU CC Wire outdoor Grille, coils AL Evaporator and CU/CU AC Condenser Louvered Coil Grille, AL indoor and AC Louvered CU/CU Grille, outdoor AL coil Evaporator and CU/ AU CU Louvered condenser Grille, Coil CU/CU indoor and AU Louvered outdoor Grille, coils CU/CU Evaporator and Condenser Coils Packaging AL Aluminum CU Copper Series V-Ph-Hz 3 208/ ARI* capacities UNIT NOMINAL TONS COOLING CAPACITIES AND EFFICIENCIES STANDARD CFM NET COOLING CAPACITIES (Btuh) SEER SOUND RATINGS (db) , / , , /2 41, , , LEGEND db Sound Levels (decibels) COP Coefficient of Performance HSPF Heating Season Performance Factor db Dry Bulb SEER Seasonal Energy Efficiency Ratio wb Wet Bulb * Air Conditioning & Refrigeration Institute. Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or ARI Standard 210/ Tested in accordance with ARI Standard (not listed in ARI). NOTES: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and 95 F db outdoor entering-air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. UNIT HIGH HEAT CAPACITY (BTUH)@47 F HEATING CAPACITIES AND EFFICIENCIES HIGH HEAT F LOW HEAT CAPACITY (BTUH)@17 F LOW HEAT F , , , , , , , , , , , , HSPF 3

4 OUTDOOR SOUND: OCTAVE BAND DATA DECIBELS UNIT Frequency (Hz) Physical data UNIT SIZE NOMINAL CAPACITY (ton) 2 2-1/ /2 4 5 OPERATING WEIGHT (lb.) Compressor Scroll Refrigerant (R-22) Quantity (lb.) REFRIGERANT METERING DEVICE Accurater Orifice ID (in.) Orifice OD (in.).032(1).038(1).035(1).038(1).038 (2).046 (2).052 (2).057 (2) CONDENSER COIL Rows Fins/in Face Area (sq. ft.) CONDENSER FAN Nominal Cfm Diameter Motor HP (RPM) 1/8 (825) 1/8 (825) 1/8 (825) 1/8 (825) 1/4 (1100) 1/4 (1100) EVAPORATOR COIL Rows Fins/in Face Area (sq. ft.) EVAPORATOR BLOWER Nominal Airflow (Cfm) Size (in.) 10x10 10x10 11x10 11x10 11x10 11x10 Motor HP (RPM) 1/3 (1050) 1/3 (1050) 1/2 (1000) 1/2 (1075) 1/2 (1075) 1 (1040) Return-Air Filters (in.)* Throwaway 20x24x1 20x24x1 24x36x1 24x36x1 24x36x1 24x36x1 * Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg. UNITARY HEAT PUMP A2325 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 ELECTRIC HEAT PRESSURE DROP TABLES Small Cabinet: STATIC CFM kw kw kw kw Large Cabinet: STATIC CFM kw kw kw kw

5 Options and accessories Factory-installed options Louvered grille provides hail and vandalism protection. A wire grille is standard on all models. See model number nomenclature for louvered grille options. Coil options include copper/copper and vinyl-coated construction for refrigerant coils. Units are shipped standard with copper tube/aluminum fin construction. See model number nomenclature for coil options. Field-installed accessories Economizer with Solid-State Controls and Barometric Relief Dampers Manual Air Damper (25% open) Electric Heaters Filter Rack Flat Roof Curbs (8-in. and 14-in.) Square-to-Round Duct Transition Kit Thermostats Controls Upgrade Kit Crankcase Heater Rigging Kit Low Ambient Kit (Motormaster II Control) Solid-State Time Guard II Device Compressor Hard Start Kit Economizer with solid-state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and reduce compressor operation. Manual outside air damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Electric heaters provide additional heat in the unit when required. Each package has a heater module that slides into the controls compartment. Heater sizes range from 5.0 to 20.0 kw. The electric heater design allows the use of a single-point power supply for the entire unit, resulting in lower installed costs. Flat roof curbs in both 8 in. and 14 in. sizes are available for roof mounted applications. Square-to-round duct transition kit enables size units to be fitted to 14 in. round ductwork. Thermostats provide control for the system heating and cooling functions. Thermostat models are available in both programmable and non-programmable versions. Controls upgrade kit supplies high and low pressure safety protection and protects the unit from operating in unsuitable conditions. Crankcase heater provides anti-floodback protection for low-load cooling applications. Rigging kit includes lifting brackets which are inserted into the unit base rigging holds to lift unit for rooftop applications. Low-ambient kit (Motormaster II control) allows the use of mechanical cooling down to outdoor temperatures as low as 0 F. Filter rack features easy installation, serviceability, and high-filtering performance for vertical and horizontal applications. Compressor Hard start kit gives a boost to the compressor motor at each start-up. ODS CATALOG ORDERING NO. ELECTRIC HEATERS NOMINAL CAPACITY USED WITH SIZES (kw) ELECTRIC HEATERS (208/230 SINGLE PHASE 60 Hz) CPHEATER052A X X X X CPHEATER064A X X CPHEATER070A X X X X X X CPHEATER050A X X X X X X CPHEATER066A X X X X X CPHEATER054A X X X LEGEND ODS Order Distribution System NOTE: Electric heaters are rated at 240 v and 480 v. Refer to Multiplication Factors table for other voltages. Minimum Airflow for Reliable Electric Heater Operation UNIT AIRFLOW

6 ECONOMIZER FILTER RACK MANUAL OUTSIDE AIR DAMPER REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD DAMPER BLADE 6

7 Base unit dimensions REQUIRED CLEARANCE TO COMBUSTIBLE MATL. (Refer to Maximum Operating Clearances) INCHES [mm] TOP OF UNIT [355.6] DUCT SIDE OF UNIT [50.8] SIDE OPPOSITE DUCTS [355.6] BOTTOM OF UNIT [12.7] NEC. REQUIRED CLEARANCES. INCHES [mm] BETWEEN UNITS, POWER ENTRY SIDE [1066.8] UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE [914.0] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE [1066.8] REQUIRED CLEARANCE FOR OPERATION AND SERVICING INCHES [mm] EVAP. COIL ACCESS SIDE [914.0] POWER ENTRY SIDE [1066.8] (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP [1219.2] SIDE OPPOSITE DUCTS [914.0] DUCT PANEL [304.8] * *MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN [12.00] FROM WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE. UNIT ELECTRICAL UNIT WEIGHT UNIT HEIGHT CENTER OF GRAVITY mm (in.) mm (in.) CHARACTERISTICS lb kg A X Y Z / (991) 20.0 (508) 19.3 (490) 17.6 (447) / (1042) 20.0 (508) 14.0 (356) 13.0 (330) 7

8 Base unit dimensions REQUIRED CLEARANCE TO COMBUSTIBLE MATL. (Refer to Maximum Operating Clearances) INCHES [mm] TOP OF UNIT [355.6] DUCT SIDE OF UNIT [50.8] SIDE OPPOSITE DUCTS [355.6] BOTTOM OF UNIT [12.7] NEC. REQUIRED CLEARANCES. INCHES [mm] BETWEEN UNITS, POWER ENTRY SIDE [1066.8] UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE [914.0] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE [1066.8] REQUIRED CLEARANCE FOR OPERATION AND SERVICING INCHES [m EVAP. COIL ACCESS SIDE [91 POWER ENTRY SIDE [10 (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP [12 SIDE OPPOSITE DUCTS [91 DUCT PANEL [30 *MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN [12.00] WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPRO UNIT ELECTRICAL UNIT WEIGHT UNIT HEIGHT CENTER OF GRAVITY mm (in.) mm (in.) CHARACTERISTICS lb kg A X Y Z / (1092) 21.0 (533) 20.5 (520) 16.6 (422) / (1193) 21.0 (533) 20.5 (520) 17.1 (434) / (1193) 21.0 (533) 20.0 (508) 17.4 (442) / (1193) 21.0 (533) 20.0 (508) 17.6 (447) 8

9 Accessory dimensions HVAC unit base Screw (NO TE A) Gasketing inner flange* Screw (NOTE A) HVAC unit base Gask eting inner flange* *Gasketing outer flange *Gasketing outer flange Flashing field supplied Wood nailer* Roofcurb* Flashing field supplied Wood nailer* Roofcurb* Roofing material field supplied Insulation (field supplied) Roofing material field supplied Insulation (field supplied) Cant strip field supplied Duct wo rk field supplied Cant strip field supplied Duct wo rk field supplied Roof Roof *Provided with roofcurb *Provided with roofcurb Roof Curb for Small Cabinet Note A: When unit mounting scre w is used, retainer bracke t must also be used. Roof Curb for Large Cabinet Note A: When unit mounting scre w is used, retainer bracket must also be used. G F B Typ. E Supply opening (B x C) D C Typ. G F R/A S/A A E D Gasket around duct Insulated deck pan Long Support Short Support Insulated deck pan Gasket around outer edge Return opening (B X C) Fig. 4 Roof Curb Dimensions UNIT SIZE ODS CATALOG NO. A IN. [MM] B in. [mm] C in. [mm] D in. [mm] E in. [mm] F in. [mm] G in. [mm] CPRFCURB006A00 8 [203] 11[279] 16 1/2 [419] 28-3/4 [730] 30-3/8 [771] 44-5/16 [1126] 45-15/16 [1167] CPRFCURB007A00 14 [356] 11[279] 16 1/2 [419] 28-3/4 [730] 30-3/8 [771] 44-5/16 [1126] 45-15/16 [1167] CPRFCURB008A00 8 [203] 16-3/16 [411] 17 3/8 [441] 40-1/4 [1022] 41-15/16 [1065] 44-7/16 [1129] 46-1/16 [1169] CPRFCURB009A00 14 [356] 16 3/16 [411] 17 3/8 [441] 40-1/4 [1022] 41-15/16 [1065] 44-7/16 [1129] 46-1/16 [1169] NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Dimensions in [ ] are in millimeters. 4. Roof curb is made of 16-gage steel. 5. Table lists only the dimensions, per part number, that have changed. 6. Attach ductwork to curb (flanges of duct rest on curb). 7. Insulated panels: 1-in. thick fiberglass 1 lb density. 8. Dimensions are in inches. 9. When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl. 9

10 Corner weights ( In Pounds) 1 2 y 4 3 x CORNER WEIGHTS (Small Cabinet) CORNER WEIGHTS (Large Cabinet) Model Unit Unit Total Weight (lbs.) Total Weight (lbs.) Model Corner Weight Corner Weight Corner Weight Corner Weight Corner Weight Corner Weight Corner Weight Corner Weight Selection Procedure (with example) I Determine cooling and heating requirements at design conditions: Given: Required Cooling Capacity (TC) ,000 Btuh Sensible Heat Capacity (SHC) ,500 Btuh Required Heating Capacity ,550 Btuh Outdoor Entering Air Temperature F Outdoor-Air Winter Design Temperature F Indoor-Air Winter Design Temperature F Indoor Entering-Air Temperature F edb 67 F ewb Indoor-Air Quantity cfm External Static Pressure in. wg Electrical Characteristics (V-Ph-Hz) edb entering dry bulb ewb entering wet bulb II Select unit based on required cooling capacity. Enter Cooling Extended Performance table at outdoor entering-air temperature of 95 F, indoor air entering at 1125 cfm and 67 F ewb (entering wet bulb). The unit will provide a total cooling capacity of 30,900 Btuh and a sensible heat capacity of 24,800 Btuh. For indoor-air temperature other than 80 F edb (entering dry bulb), calculate sensible heat capacity correction, as required, using the formula found in Note 3 following the cooling capacities tables. NOTE: Unit ratings are net capacities. 10 III Select electric heat. Enter the unit Heating Extended Performance table at 1125 cfm. At 70 F return indoor air and 20 F air entering outdoor coil, the integrated heating capacity is 16,200 Btuh. (Select integrated heating capacity value since deductions for outdoor-coil frost and defrosting have already been made. No correction is required.) The required heating capacity is 28,550 Btuh. Therefore, 12,350 Btuh (28,550 16,200) additional electric heat is required. Determine additional electric heat capacity in kw. 12,350 Btuh = 3.6 kw of heat required 3414 Btuh/kW Enter the Electric Heater table on page 5 for 208/230 v, single-phase, unit. The 5-kW heater at 240 v most closely satisfies the heating required. To calculate kw at 230 v, multiply the heater kw by multiplication factor 0.92 found in the Multiplication Factors table on page kw x 0.92 = 4.6 kw 4.6 kw x 3414 = 15,704 Btuh Total unit heating capacity is 31,900 Btuh (16, ,704). IV Determine fan speed and power requirements at design conditions. Before entering the air delivery tables, calculate the total static pressure required.

11 Performance data 024 (2 TONS) Temp (F) Air Ent Outdoor Coil (Edb) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF 700/ / /0.11 Indoor Entering Air Ewb (F) * * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (2 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw (2 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb. 11

12 Performance data (cont) 030 (2-1/2 TONS) 12 Temp (F) Air Ent Outdoor Coil (Edb) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF 875/ / /0.10 Indoor Entering Air Ewb (F) * * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (2-1/2 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil (2-1/2 TONS) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb.

13 Performance data (cont) 036 (3 TONS) Temp (F) Air Ent Outdoor Coil (Edb) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF 1050/ / /0.10 Indoor Entering Air Ewb (F) * * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (3 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil (3 TONS) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb. 13

14 Performance data (cont) 042 (3-1/2 TONS) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF Temp (F) Air Ent 1225/0.11 / /0.14 Outdoor Coil Indoor Entering Air Ewb (F) (Edb) * * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (3-1/2 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil (3-1/2 TONS) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb. 14

15 Performance data (cont) 048 (4 TONS) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF Temp (F) Air Ent / / /0.09 Outdoor Coil Indoor Entering Air Ewb (F) (Edb) * * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (4 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil (4 TONS) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb. 15

16 Performance data (cont) 060 (5 TONS) COOLING EXTENDED PERFORMANCE TABLE Indoor Entering Air CFM/BF Temp (F) Air Ent 1750/ / /0.09 Outdoor Coil Indoor Entering Air Ewb (F) (Edb) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw (5 TONS) HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil (5 TONS) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw HEATING EXTENDED PERFORMANCE TABLE Temp (F) Indoor Air Cfm (std) Air Temperature Entering Outdoor Coil (F db at 70% rh) Air Ent Indoor Coil TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw See Legend and Notes on page 17. *At 75 F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80 F entering dry bulb.

17 17

18 Performance data (cont) ECONOMIZER 1-in. FILTER PRESSURE DROP (in. wg) UNIT PRESSURE DROP MULTIPLICATION FACTORS HEATER kw RATING 240 Example: 20 kw (at 240v) heater on 230v = 20.0 (.92 mult factor) = 18.4 kw capacity at 230 v LEGEND BF Bypass Factor Ewb Entering Wet-Bulb kw Total Unit Power Input SHC Sensible Heat Capacity (1000 Btuh) TC Total Capacity (1000 Btuh) (net) Edb Entering Dry-Bulb rh Relative Humidity Indicates Integrated Ratings VOLTAGE DISTRIBUTION V/3/ MULTIPLICATION FACTOR NOTES: 1. Ratings are net; they account for the effects of the evaporator-fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: sensible capacity (Btuh) t = t ldb edb 1.10 x cfm t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving evaporator coil (h lwb) total capacity (Btuh) h lwb = hewb 4.5 x cfm Where: h = Enthalpy of air entering evaporator coil ewb 4. The SHC is based on 80 F edb temperature of air entering evaporator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC. Above 80 F edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 BF) x (edb 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 18

19 WET COIL AIR DELIVERY UNIT * 230 VOLT Unit External Static Pressure (in.wg) Motor Speed LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M LO Watts C.F.M MED Watts C.F.M HI Watts C.F.M *Air delivery values are based on operating voltage of 230 v, wet coil, without filter or electric heater. Deduct filter and electric heater pressure drops to obtain static pressure available for ducting. NOTES: 1.Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below this point. 2.Dashes indicate portions of table that are beyond the blower motor capacity or are not recommended. 3.Deduct 10% for 208v. FILTER PRESSURE DROP (In. wg) UNIT SIZE CFM FILTER SIZE , X 20 X X 24 X , 048, X 30 X

20 Typical piping and wiring INDOOR THERMOSTAT RETURN AIR TOP COVER FROM POWER SOURCE DISCONNECT PER NEC 20

21 Application data Condensate trap A 2-in. condensate trap must be field supplied. 1 MIN. TRAP OUTLET 2 MIN. Ductwork Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge Units are equipped with factory-installed inserts in the downflow openings. Remove the inserts similar to removing an electrical knock-out. Maximum cooling airflow To minimize the possibility of condensate blow-off from the evaporator, airflow through the units should not exceed 450 cfm/ton. Minimum cooling airflow The minimum cooling airflow is 350 cfm/ton. Minimum cooling ambient operating temperature All standard units have a minimum ambient operating temperature of 40 F. With accessory low ambient temperature kit, units can operate at temperatures down to 0 F. 21

22 Electrical Data UNIT SIZE VOLTAGE RANGE COMPRESSOR FAN OUTDOOR MOTOR FAN INDOOR MOTOR ELECTRIC HEAT POWER SUPPLY V-PH-Hz Max Fuse or Min Max RLA LRA FLA FLA Nominal kw* FLA MCA Ckt Bkr MOCP 16.5/ / / /5 18.1/ / /30 7.5/ / / /60 5.4/7.2 26/ / / / /25 3.8/5 18.1/ / / / / / / / / / / /90 5.4/7.2 26/ / / / /30 3.8/5 18.1/ / / / / / / / / / / /90 5.4/7.2 26/ / / / /35 3.8/5 18.1/ / / / / / / / / / / /90 15/ / / / /7.2 26/ / / / /35 3.8/5 18.1/ / / / / / / / / / / /90 15/ / / / /7.2 26/ / / / /50 3.8/5 18.1/ / / / / / / / / / / /90 15/ / / / /7.2 26/ / /50 *Heater capacity (kw) based on heater voltage of 208v, 240v, & 480v. If power distribution voltage to unit varies from rated heater voltage, heater kw will vary accordingly. 22

23 Electrical Data Legend LEGEND FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection RLA Rated Load Amps *Heater capacity (KW) based on heater voltage of 208v, 240v, & 480v. If power distribution voltage to unit varies from rated heater voltage, heater KW will vary accordingly. NOTES: 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse. The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on 60 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. 3. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage imbalance max voltage deviation from average voltage = 100 x average voltage EXAMPLE: Supply voltage is AB = 452 v BC = 464 v AC = 455 v Average Voltage = = 3 = 457 Determine maximum deviation from average voltage. (AB) =5v (BC) =7v (AC) =2v Maximum deviation is 7 v. Determine percent of voltage imbalance. 7 % Voltage Imbalance = 100 x 457 = 1.53% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. 23

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( )

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( ) Single---Packaged Air Conditioner System 2 to 5 Nominal Tons (024---060) Product Data Unit A05194 The unit is a packaged air conditioner for manufactured housing, residential, and light commercialapplications.

More information

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT 50JZ (50Hz.)-C1SB 50JZ 7 to 14 kw (024-048) STANDARD EFFICIENCY SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB

More information

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TFQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TJQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat

More information

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase)

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) PAE Product Specifications COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP COMMERCIAL Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP Sizes 024-180 STANDARD AND HIGH EFFICIENCY DuraPac and DuraPac Plus HEAT PUMP UNITS 2 to 15 Tons 50-1219 548F036-072 549B036-072 50-1304

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFQ008-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 50 Hz Nominal Capacities: 26.4 to 35.2 kw (7 1 / 2 to 10 Nominal Tons) Single-package standard efficiency rooftop heat

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

Product Data. Fig. 1 - Unit 48VG -A and 48VG -B

Product Data. Fig. 1 - Unit 48VG -A and 48VG -B VG---A and VG---B Performancet 16 SEER 2---Stage Packaged Air Conditioner and Gas Furnace System with PuronR (R---0A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig.

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE)

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE) PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP -2 TONS ( PHASE) REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number * COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual,

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12.

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12. Product Data 50TFF004-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 3 to 12.5 Nominal Tons Standard-Efficiency Rooftop Units with: Pre-painted galvanized steel cabinet for

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFF007-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz Nominal Capacity: 17.6 kw to 35.9 kw (5 to 10.2 Tons) Single-Package Rooftop Units with: Galvanized

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

Model 558D/559F Sizes

Model 558D/559F Sizes Bryant Air Conditioning COMMERCIAL SINGLE-PACKAGE ROOFTOP ELECTRIC COOLING UNITS Model 558D/559F Sizes 036-300 3to25Tons Model 558D036-072 Model 559F180,216 Model 558D090-150 Model 559F240,300 DESCRIPTION

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units Product Data 50TJ008-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units Nominal Capacity: 21.5 kw to 35.9 kw (6.1 to 10.2 Tons) Single-Package Rooftop Units with:

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS 07---25 SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz Product Data 07-12 16-25 C10887 Carrier s versatile packaged heat pump air-handling units satisfy design requirements

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES, AND MODELS 2-5 TON 60 Hertz Description These York Affinity packaged heat pumps are designed for outdoor installation. Only utility and duct connections are required

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase)

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase) RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, single packaged heat pump units that are

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SE Series M1200 Product Line Single Packaged Heat Pump 14 SEER - 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

38AUM Air Cooled Condensing Units 50Hz

38AUM Air Cooled Condensing Units 50Hz 38AUM Air Cooled Condensing Units 50Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE RAS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, 14 20 TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency electric

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

High Cap. (Btuh) HSPF COP

High Cap. (Btuh) HSPF COP RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE R 410A HFC refrigerant ASHRAE 90.1 Energy Compliant