Equipment wires & cables

Size: px
Start display at page:

Download "Equipment wires & cables"

Transcription

1 Equipment wires & cables for high temperatures

2 Equipment wires & cables for high temperatures

3 Contents General Information 4 Introduction, applications, quality insurance...4 Axon reference identification code...5 Colour code...6 Standard multicores...6 Products according to NF standard...7 Products according to NEMA standard...11 Single wires Extruded version 15 PTFE insulation with SPC or SCA conductor: -90 C / +200 C - UT, ET, E, EE...17 PTFE insulation with NPC conductor: -90 C / +260 C - ET, E, EE...21 PTFE insulation with SPC conductor: -65 C / +200 C - SAE-AS22759/ PTFE insulation with NPC conductor: -65 C / +260 C - SAE-AS22759/ PTFE insulation with SCA conductor: -65 C / +200 C - SAE-AS22759/ PTFE insulation with NCA conductor: -65 C / +260 C - SAE - AS22759/ FEP insulation with SPC or SCA conductor: -90 C / +200 C - UKT, KT, K, KK...28 FEP insulation with TPC conductor: - 55 C /+150 C - KT, K...30, 32 ETFE insulation with TPC conductor: -90 C / +155 C - ZL, ZN, ZZ...34 ETFE insulation with SPC conductor: -90 C / +155 C - ZA, ZLA...37

4 3 Single wires Taped version 39 PTFE tape insulation with SPC conductor: -90 C / +200 C - RET, RE, REE...41 PTFE tape insulation with NPC conductor: -90 C / +260 C - RET, RE, REE...44 Polyimide tape insulation with SPC or SCA conductor: -90 C / +200 C - HT, H...47 Polyimide and PTFE tape insulation with SPC conductor: -90 C / +200 C - HET,HE...49 Shielded wires and cables 51 PTFE insulation with SPC or SCA conductor: -90 C / +200 C - ET, E, EE, KZ...53 FEP insulation with SPC or SCA conductor: -90 C / +200 C - KT, K, KK...74 Shielded and jacketed wires and cables 83 PTFE insulation with SPC or SCA conductor: -90 C / +200 C - UT, ET, E, EE, KZ...85 FEP insulation with SPC or SCA conductor: -90 C / +200 C - KT, K, KK FEP insulation with TPC conductor: -55 C / +150 C - KT, K ETFE insulation with TPC conductor: -90 C / +155 C - ZL, ZN ETFE insulation with TPC conductor: -55 C / +150 C - KU Extra flexible wires and cables 147 Single wires: wrapped PTFE tape insulation with SPC conductor: -90 C / +200 C - RET, RE Shielded and jacketed cables: wrapped PTFE tape insulation with SPC conductor: -90 C / +200 C - RET, RE Wire-wrap single wires 157 Single wires: PTFE insulation with SPC or SCA conductor: -90 C / +200 C - AET, WET, WE, Single wires: FEP insulation with SPC conductor: -90 C / +200 C: AKT, WKT, WK, Single wires: ETFE insulation with SPC or SCA conductor: -90 C / +155 C: AZT, WZT, WZ Single wires: wrapped polyimide insulation with SPC or SCA conductor: -90 C / +200 C: AHT, WHT, WH Appendices 163 S CONFIGURATIONS DIMENSIONS FEATURES OF MATERIALS MAIN CHARACTERISTICS OF MATERIALS LIST OF THE MAIN SUITABLE FOR THE CABLE STRUCTURE UNDERWRITERS LABORATORIES APPLIANCE WIRE Glossary 177

5 4 General information Introduction offers an extended range of equipment wires for use between 90 C and 260 C insulated with the following materials: PTFE Polytetrafluorethylene with SPC conductor: -90 C to +200 C with NPC conductor: -90 C to +260 C. FEP Fluorethylenepropylene -90 C to +200 C. ETFE Ethylenetetrafluorethylene -90 C to 155 C. Polyimide+FEP Polyimide (+FEP coating for heat sealing and FEP or PTFE lacquer for colouration) -90 C to +200 C. Polyimide+PTFE Polyimide + PTFE tape -90 C to +200 C. This catalogue consists of data sheets detailing the dimensional, electrical and mechanical features of all standard single wires. Shielded and / or multicore cables can also be proposed. also offers other conductors/ insulation confi gurations like i.e. extra fl exible wires with TPC conductor and FEP jacket. Do not hesitate to send us your requirements. We will be happy to help. Applications Equipment wires are used in many different areas: aeronautics automotive space electronics military equipment general industry medical,... Quality assurance obtained ISO 9001 certifi cation in 1996 through AFAQ (Association Française pour l Assurance Qualité) who are an EQ-NET member. In addition, the company is TS 16949, EN 9100 and ISO certifi ed. s products meet or exceed several international standards: ESA, UL, CSA, NF, NEMA, and a number of products are listed on QPL. All products are carefully inspected during production and before dispatch. A certifi cate of conformity can be provided on request. To conform to environmental and safety requirements has also obtained ISO and OHSAS certifi cations. Several national and international bodies regularly re-assess s Quality Assurance organisation. NOTE: may choose different standards for their products in accordance with market evolution. FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require.

6 5 Axon reference identifi cation code MULTICORE CABLE SHIELDED CABLE SINGLE WIRE Use of wire extruded equipment wire = Empty wire-wrap wire = W miniature wire (160 Volts AC) = U miniature wire-wrap wire = A taped and sintered equipment wire = R Primary insulation material PTFE = E FEP = K Polyimide = H ETFE = Z Voltage rating 600 Volts AC - light weight = L 600 Volts AC - medium weight = N 250 Volts AC = T 600 Volts AC = Empty 1000 Volts AC: Insulation code repeated Conductor size (AWG) Conductor stranding number of strands Additional tape Polyimide separating tape = H Screening standard braid without jacket = S standard braid with jacket = ST x helicoidal screen + jacket = Sh x Type of jacket FEP = K Polyimide = H Wrapped and sintered PTFE = E ETFE = Z Number of wires 1, 2, 3, 4, etc. R E T H S T K 1 X X X X X X X X X X X X FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require.

7 6 Colour code S OR STRIPES COLOURS ARE CODED ACCORDING TO THE TABLE BELOW CODE NATURAL BLACK BROWN RED ORANGE YELLOW GREEN BLUE VIOLET GREY WHITE FRENCH A B C D E F G H J K L INTERNATIONAL FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require. Standard multicores Standard multicores (unshielded, non-jacketed twisted pairs, triples and quads) are part of the production range. Their references are built by placing 2x, 3x or 4x in front of the reference of the primary wire. For example: 2 x E 3201 = a twisted pair composed of 2 PTFE insulated single wires gauge STANDARD MULTICORES BUNDLE OUTER DIAMETER Twisted pairs 2 x (single wire reference) 2 x (single wire outer ø) Twisted triples 3 x (single wire reference) 2.15 x (single wire outer ø) Twisted quads 4 x (single wire reference) 2.41 x (single wire outer ø) The general features of the standard multicores, other than the outer diameter of the bundle, are easily calculated using the single wire technical sheets. FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require. ALL TECHNICAL DATA IS GIVEN FOR INFORMATION ONLY AND MAY BE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.

8 7 Products according to NF Standard APPROVED PAGES NF-C KW B1 WZT KW B1 WZT KW B1 WZT KW B1 WZ NF-C KW A2 WET WKT , 160 KW A2 WET WKT , 160 KW A2 WET WKT , 160 KW A2 WE WK , 160 NF-C KW B1 WZT NF-C-93523/4 KZ (R) ET , 41 KZ (R) ET , 41 KZ (R) ET , 41 KZ (R) ET , 41 KZ (R) ET , 41 KZ (R) ET , 41 KZ (R) ET , 41 NF-C-93523/5 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ (R) E , 42 KZ RE KZ RE NF-C-93523/6 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ (R) EE , 43 KZ REE KZ REE NF-C-93523/7 KZ ET 3207 NPC 21 KZ ET 3007 NPC 21 KZ ET 2807 NPC 21 KZ ET 2607 NPC 21 KZ ET 2407 NPC 21 KZ ET 2207 NPC 21 KZ ET 2019 NPC 21

9 8 Products according to NF Standard APPROVED PAGES NF-C-93523/8 KZ E 3207 NPC 22 KZ E 3007 NPC 22 KZ E 2807 NPC 22 KZ E 2607 NPC 22 KZ E 2407 NPC 22 KZ E 2207 NPC 22 KZ E 2019 NPC 22 KZ E 1819 NPC 22 KZ E 1619 NPC 22 NF-C-93523/9 KZ EE 3207 NPC 23 KZ EE 3007 NPC 23 KZ EE 2807 NPC 23 KZ EE 2607 NPC 23 KZ EE 2407 NPC 23 KZ EE 2207 NPC 23 KZ EE 2019 NPC 23 KZ EE 1819 NPC 23 KZ EE 1619 NPC 23 NF-C KZ ET 2607 H STK KZ ET 2407 H STK KZ ET 2207 H STK KZ ET 2019 H STK NF-C KZ E 3207 STK KZ E 3007 STK KZ E 2807 STK KZ E 2607 STK KZ E 2407 STK KZ E 2207 STK KZ E 2019 STK KZ E 1819 STK KZ E 1619 STK KZ RE 1427 STK KZ RE 1245 STK NF-C KZ EE 3207 STK KZ EE 3007 STK KZ EE 2807 STK KZ EE 2607 STK KZ EE 2407 STK KZ EE 2207 STK KZ EE 2019 STK KZ EE 1819 STK KZ EE 1619 STK KZ REE 1427 STK KZ REE 1245 STK NF-C KZ ET 3207 H STK KZ ET 3007 H STK KZ ET 2807 H STK KZ ET 2607 H STK KZ ET 2407 H STK KZ ET 2207 H STK KZ ET 2019 H STK 2 102

10 9 Products according to NF Standard APPROVED PAGES NF-C KZ E 3207 STK KZ E 3007 STK KZ E 2807 STK KZ E 2607 STK KZ E 2407 STK KZ E 2207 STK KZ E 2019 STK KZ E 1819 STK KZ E 1619 STK KZ RE 1427 STK KZ RE 1245 STK NF-C KZ EE 3207 STK KZ EE 3007 STK KZ EE 2807 STK KZ EE 2607 STK KZ EE 2407 STK KZ EE 2207 STK KZ EE 2019 STK KZ EE 1819 STK KZ EE 1619 STK KZ REE 1427 STK KZ REE 1245 STK NF-C KZ ET 3207 H STK KZ ET 3007 H STK KZ ET 2807 H STK KZ ET 2607 H STK KZ ET 2407 H STK KZ ET 2207 H STK KZ ET 2019 H STK NF-C KZ E 3207 STK KZ E 3007 STK KZ E 2807 STK KZ E 2607 STK KZ E 2407 STK KZ E 2207 STK KZ E 2019 STK KZ E 1819 STK KZ E 1619 STK KZ RE 1427 STK KZ RE 1245 STK NF-C KZ EE 3207 STK KZ EE 3007 STK KZ EE 2807 STK KZ EE 2607 STK KZ EE 2407 STK KZ EE 2207 STK KZ EE 2019 STK KZ EE 1819 STK KZ EE 1619 STK KZ REE 1427 STK KZ REE 1245 STK 3 109

11 10 Products according to NF Standard APPROVED PAGES NF-C KU ZL KU ZL KU ZL KU ZL KU ZL KU ZN KU ZN KU ZN KU ZN KU ZN NF-C KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU NF-C KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU NF-C KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU NOTE KZ - Although the temperature range of PTFE wires is -90 C/+260 C, the French standard limits it to -55 C/+260 C. KU - Although the temperature range of ETFE wires is -90 C/+150 C, the French standard limits it to -55 C/+150 C. FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require.

12 11 Products according to NEMA Standard US PAGES NEMA HP3 (ex MIL-W-16878/4) HP3-EXDBA E 3001 SCA 19 HP3-EXBBA E WE , 159 HP3-EXDBB E 3007 SCA 19 HP3-EXBBB E HP3-EXBCB E HP3-EXBDA E WE , 159 HP3-EXBDB E HP3-EXBEA E WE , 159 HP3-EXBEB E HP3-EXBFA E HP3-EXBFB E HP3-EXBGA E HP3-EXBGB E NEMA HP3 (ex MIL-W-16878/5) HP3-EEXBAB EE HP3-EEXBBA EE HP3-EEXBBB EE HP3-EEXBCA EE HP3-EEXBDA EE HP3-EEXBDB EE HP3-EEXBEA EE HP3-EEXBEB EE HP3-EEXBFA EE HP3-EEXBFB EE HP3-EEXBGA EE HP3-EEXBGB EE NEMA HP3 (ex MIL-W-16878/6) HP3-ETXDBA ET 3001 SCA 18 HP3-ETXBBA ET WET , 159 HP3-ETXDBB ET 3007 SCA 18 HP3-ETXBBB ET HP3-ETXBCB ET HP3-ETXBDA ET WET , 159 HP3-ETXDDB ET 2607 SCA 18 HP3-ETXBDB ET HP3-ETXBEA ET WET , 159 HP3-ETXBEB ET HP3-ETXBFA ET HP3-ETXBFB ET HP3-ETXBGA ET HP3-ETXBGB ET NEMA HP4 (ex MIL-W-16878/11) HP4-KBAA K HP4-KBBA K WK , 160 HP4-KBBB K HP4-KBCB K HP4-KBDA K WK , 160 HP4-KBDB K HP4-KBEA K WK , 160 HP4-KBEB K HP4-KBFA K HP4-KBFB K HP4-KBGA K

13 12 Products according to NEMA Standard US PAGES NEMA HP4 (ex MIL-W-16878/12) HP4-KKBAB KK HP4-KKBBA KK HP4-KKBBB KK HP4-KKBCA KK HP4-KKBCB KK HP4-KKBDA KK HP4-KKBDB KK HP4-KKBDE KK HP4-KKBEA KK HP4-KKBEB KK HP4-KKBEE KK HP4-KKBFA KK HP4-KKBFB KK HP4-KKBFE KK HP4-KKBGA KK HP4-KKBGB KK HP4-KKBGE KK HP4-KKBHE KK HP4-KKBKE KK HP4-KKBLE KK HP4-KKBMG KK HP4-KKBNL KK HP4-KKBPL KK HP4-KKBRL KK HP4-KKBSP KK NEMA HP4 (ex MIL-W-16878/13) HP4-KTBAA KT HP4-KTBBA KT WKT , 160 HP4-KTBBB KT HP4-KTBCB KT HP4-KTBDA KT WKT , 160 HP4-KTBDB KT HP4-KTBEA KT WKT , 160 HP4-KTBEB KT HP4-KTBFA KT HP4-KTBFB KT HP4-KTBGA KT HP4-KTBGB KT NEMA HP3 (ex MIL-W-16878/20) HP3-ETWBBB RET HP3-ETWBCB RET HP3-ETWBDB RET HP3-ETWBEB RET HP3-ETWBFB RET NEMA HP3 (ex MIL-W-16878/21) HP3-EWBBB RE HP3-EWBCB RE HP3-EWBDB RE HP3-EWBEB RE HP3-EWBFB RE

14 13 Products according to NEMA Standard US PAGES NEMA HP3 (ex MIL-W-16878/22) HP3-EEWBAB REE HP3-EEWBBB REE HP3-EEWBCB REE HP3-EEWBDB REE HP3-EEWBDE REE HP3-EEWBEB REE HP3-EEWBEE REE HP3-EEWBFB REE HP3-EEWBFE REE HP3-EEWBGE REE HP3-EEWBHE REE HP3-EEWBMG REE HP3-EEWBNL REE NEMA HP3 (ex MIL-W-16878/23) HP3-ETXCBA ET 3001 NPC 21 HP3-ETXCBB ET 3007 NPC 21 HP3-ETXCCB ET 2807 NPC 21 HP3-ETXCDB ET 2607 NPC 21 HP3-ETXCEB ET 2407 NPC 21 HP3-ETXCFA ET 2201 NPC 21 HP3-ETXCFB ET 2207 NPC 21 HP3-ETXCGA ET 2001 NPC 21 HP3-ETXCGB ET 2007 NPC 21 NEMA HP3 (ex MIL-W-16878/24) HP3-ETWCBB RET 3007 NPC 44 HP3-ETWCCB RET 2807 NPC 44 HP3-ETWCDB RET 2607 NPC 44 HP3-ETWCEB RET 2407 NPC 44 HP3-ETWCFB RET 2207 NPC 44 NEMA HP3 (ex MIL-W-16878/25) HP3-EXCBB E 3007 NPC 22 HP3-EXCDB E 2607 NPC 22 HP3-EXCEB E 2407 NPC 22 HP3-EXCFB E 2207 NPC 22 HP3-EXCGA E 2001 NPC 22 HP3-EXCGB E 2007 NPC 22 NEMA HP3 (ex MIL-W-16878/26) HP3-EWCBB RE 3007 NPC 45 HP3-EWCCB RE 2807 NPC 45 HP3-EWCDB RE 2607 NPC 45 HP3-EWCEB RE 2407 NPC 45 HP3-EWCFB RE 2207 NPC 45 NEMA HP3 (ex MIL-W-16878/27) HP3-EEXCAB EE 3207 NPC 23 HP3-EEXCBA EE 3001 NPC 23 HP3-EEXCBB EE 3007 NPC 23 HP3-EEXCCA EE 2801 NPC 23 HP3-EEXCDA EE 2601 NPC 23 HP3-EEXCDB EE 2607 NPC 23 HP3-EEXCEA EE 2401 NPC 23 HP3-EEXCEB EE 2407 NPC 23 HP3-EEXCFA EE 2201 NPC 23

15 14 Products according to NEMA Standard US PAGES NEMA HP3 (ex MIL-W-16878/27) HP3-EEXCFB EE 2207 NPC 23 HP3-EEXCGA EE 2201 NPC 23 HP3-EEXCGB EE 2007 NPC 23 NEMA HP3 (ex MIL-W-16878/28) HP3-EEWCAB REE 3207 NPC 46 HP3-EEWCBB REE 3007 NPC 46 HP3-EEWCCB REE 2807 NPC 46 HP3-EEWCDB REE 2607 NPC 46 HP3-EEWCDE REE 2619 NPC 46 HP3-EEWCEB REE 2407 NPC 46 HP3-EEWCEE REE 2419 NPC 46 HP3-EEWCFB REE 2207 NPC 46 HP3-EEWCFE REE 2219 NPC 46 HP3-EEWCGE REE 2019 NPC 46 HP3-EEWCHE REE 1819 NPC 46 HP3-EEWCMG REE 1037 NPC 46 According to the NEMA standard, extruded or taped PTFE or FEP single wires with a voltage of 600 or 1000 volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not. FURTHER INFORMATION > Our sales team is at your disposal for any advice you may require.

16 15 Extruded single wires Axon offers a range of extruded single wires resistant to high temperatures: - From -55 C to +260 C: PTFE insulation - From -55 C to +200 C: FEP insulation - From -90 C to +155 C: ETFE insulation

17

18 PTFE Ultra miniature single wires -90 C / +200 C 17 ASTM-B-624 ASTM-D-4895 UT xxxx SPC or SCA Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page 6 Extruded single wires Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) UT 3601 SCA 36 1x UT 3607 SCA 36 7x UT 3401 SCA 34 1x UT 3407 SCA 34 7x UT 3201 SCA 32 1x UT 3207 SCA 32 7x UT 3219 SCA 32 19x UT 3001 SCA 30 1x UT 3007 SCA 30 7x UT 3019 SCA 30 19x UT x UT x UT 2819 SCA 28 19x UT x APPROX. WEIGHT

19 18-90 C / +200 C PTFE Single wires Extruded single wires ASTM-B-624 ASTM-D-4895 NF-C-93523/4 NEMA-HP3 Insulation: PTFE ET xxxx SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard multicores: see page Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) ET 3601 SCA 36 1x ET 3607 SCA 36 7x ET 3401 SCA 34 1x ET 3407 SCA 34 7x ET 3201 SCA 32 1x ET x ET 3207 SCA 32 7x ET 3207 KZ x ET 3219 SCA 32 19x ET 3001 SCA HP3-ETXDBA 30 1x ET 3001 HP3-ETXBBA 30 1x ET 3007 SCA HP3-ETXDBB 30 7x ET 3007 KZ HP3-ETXBBB 30 7x ET 3019 SCA 30 19x ET x ET 2807 KZ HP3-ETXBCB 28 7x ET 2819 SCA 28 19x ET x ET 2601 HP3-ETXBDA 26 1x ET 2607 SCA HP3-ETXDDB 26 7x ET 2607 KZ HP3-ETXBDB 26 7x ET 2619 SCA 26 19x ET x ET 2401 HP3-ETXBEA 24 1x ET 2407 KZ HP3-ETXBEB 24 7x ET x ET 2201 HP3-ETXBFA 22 1x ET 2207 KZ HP3-ETXBFB 22 7x ET x ET 2001 HP3-ETXBGA 20 1x ET 2007 HP3-ETXBGB 20 7x ET 2019 KZ x APPROX. WEIGHT

20 PTFE Single wires -90 C / +200 C 19 ASTM-B-624 ASTM-D-4895 NF-C-93523/5 NEMA-HP3 Insulation: PTFE E xxxx SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT E 3601 SCA 36 1x E 3607 SCA 36 7x E 3401 SCA 34 1x E 3407 SCA 34 7x E 3201 SCA 32 1x E x E 3207 KZ x E 3219 SCA 32 19x E 3001 SCA HP3-EXDBA 30 1x E 3001 HP3-EXBBA 30 1x E 3007 SCA HP3-EXDBB 30 7x E 3007 KZ HP3-EXBBB 30 7x E 3019 SCA 30 19x E x E 2807 KZ HP3-EXBCB 28 7x E x E 2601 HP3-EXBDA 26 1x E 2607 KZ HP3-EXBDB 26 7x E 2619 SCA 26 19x E x E 2401 HP3-EXBEA 24 1x E 2407 KZ HP3-EXBEB 24 7x E x E 2201 HP3-EXBFA 22 1x E 2207 KZ HP3-EXBFB 22 7x E x E 2001 HP3-EXBGA 20 1x E 2007 HP3-EXBGB 20 7x E 2019 KZ x E 1819 KZ x E 1619 KZ x E x E x According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

21 20-90 C / +200 C Single wires PTFE Extruded single wires ASTM-B-624 ASTM-D-4895 NF-C-93523/6 NEMA-HP3 Insulation: PTFE EE xxxx SPC or SCA Operating temperature: -90C / +200 C Voltage rating: 1000 Volts AC upon request Standard multicores: see page Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) EE x EE 3207 KZ HP3-EEXBAB 32 7x EE 3219 SCA 32 19x EE 3001 HP3-EEXBBA 30 1x EE 3007 KZ HP3-EEXBBB 30 7x EE 3019 SCA 30 19x EE 2801 HP3-EEXBCA 28 1x EE 2807 KZ x EE x EE 2601 HP3-EEXBDA 26 1x EE 2607 KZ HP3-EEXBDB 26 7x EE x EE 2401 HP3-EEXBEA 24 1x EE 2407 KZ HP3-EEXBEB 24 7x EE x EE 2201 HP3-EEXBFA 22 1x EE 2207 KZ HP3-EEXBFB 22 7x EE x EE 2001 HP3-EEXBGA 20 1x EE 2007 HP3-EEXBGB 20 7x EE 2019 KZ x EE 1819 KZ x EE 1619 KZ x EE x EE x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

22 PTFE Single wires -90 C/+260 C 21 ASTM-B-355 ASTM-D-4895 NF-C-93523/7 NEMA-HP3 Insulation: PTFE Operating temperature: -90C /+260C Voltage rating: 250 Volts AC ET xxxx NPC upon request Standard multicores: see page 6 Extruded single wires Conductor: electrolytic nickel plated annealed copper 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) ET 3201 NPC 32 1x ET 3207 NPC KZ x ET 3001 NPC HP3-ETXCBA 30 1x ET 3007 NPC KZ HP3-ETXCBB 30 7x ET 2807 NPC KZ HP3-ETXCCB 28 7x ET 2819 NPC 28 19x ET 2607 NPC KZ HP3-ETXCDB 26 7x ET 2619 NPC 26 19x ET 2407 NPC KZ HP3-ETXCEB 24 7x ET 2419 NPC 24 19x ET 2201 NPC HP3-ETXCFA 22 1x ET 2207 NPC KZ HP3-ETXCFB 22 7x ET 2219 NPC 22 19x ET 2001 NPC HP3-ETXCGA 20 1x ET 2007 NPC HP3-ETXCGB 20 7x ET 2019 NPC KZ x APPROX. WEIGHT

23 22-90 C/+260 C Single wires PTFE Extruded single wires ASTM-B-355 ASTM-D-4895 NF-C-93523/8 NEMA-HP3 Insulation: PTFE Operating temperature: -90 C/+260 C Voltage rating: 600 Volts AC E xxxx NPC Standard multicores: see page Conductor: electrolytic nickel plated annealed copper 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) E 3201 NPC 32 1x E 3207 NPC KZ x E 3007 NPC KZ HP3-EXCBB 30 7x E 2801 NPC 28 1x E 2807 NPC KZ x E 2819 NPC 28 19x E 2607 NPC KZ HP3-EXCDB 26 7x E 2619 NPC 26 19x E 2407 NPC KZ HP3-EXCEB 24 7x E 2419 NPC 24 19x E 2207 NPC KZ HP3-EXCFB 22 7x E 2219 NPC 22 19x E 2001 NPC HP3-EXCGA 20 1x E 2007 NPC HP3-EXCGB 20 7x E 2019 NPC KZ x E 1819 NPC KZ x E 1619 NPC KZ x E 1419 NPC 14 19x E 1219 NPC 12 19x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

24 PTFE Single wires -90 C/+260 C 23 ASTM-B-355 ASTM-D-4895 NF-C-93523/9 NEMA-HP3 Insulation: PTFE Operating temperature: -90 C/+260 C Voltage rating: 1000 Volts AC EE xxxx NPC Standard multicores: see page 6 Extruded single wires Conductor: electrolytic nickel plated annealed copper 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) EE 3201 NPC 32 1x EE 3207 NPC KZ HP3-EEXCAB 32 7x EE 3001 NPC HP3-EEXCBA 30 1x EE 3007 NPC KZ HP3-EEXCBB 30 7x EE 2801 NPC HP3-EEXCCA 28 1x EE 2807 NPC KZ x EE 2819 NPC 28 19x EE 2601 NPC HP3-EEXCDA 26 1x EE 2607 NPC KZ HP3-EEXCDB 26 7x EE 2619 NPC 26 19x EE 2401 NPC HP3-EEXCEA 24 1x EE 2407 NPC KZ HP3-EEXCEB 24 7x EE 2419 NPC 24 19x EE 2201 NPC HP3-EEXCFA 22 1x EE 2207 NPC KZ HP3-EEXCFB 22 7x EE 2219 NPC 22 19x EE 2001 NPC HP3-EEXCGA 20 1x EE 2007 NPC HP3-EEXCGB 20 7x EE 2019 NPC KZ x EE 1819 NPC KZ x EE 1619 NPC KZ x EE 1419 NPC 14 19x EE 1219 NPC 12 19x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

25 24-65 C / +200 C Single wires PTFE Extruded single wires ASTM-D-4895 SAE-AS22759 Insulation: PTFE SAE-AS22759/11 Operating temperature: -65 C / +200 C Voltage rating: 600 Volts AC Standard multicores: see page Conductor: stranded silver plated copper 2 - Insulation: extruded PTFE SAE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT E759/11-28 SPC M22759/ x E759/11-26 SPC M22759/ x E759/11-24 SPC M22759/ x E759/11-22 SPC M22759/ x E759/11-20 SPC M22759/ x E759/11-18 SPC M22759/ x E759/11-16 SPC M22759/ x E759/11-14 SPC M22759/ x E759/11-12 SPC M22759/ x E759/11-10 SPC M22759/ x E759/11-8 SPC M22759/ x

26 PTFE Single wires -65 C / +260 C 25 ASTM-B-355 ASTM-D-4895 SAE-AS22759 Insulation: PTFE SAE-AS22759/12 Operating temperature: -65 C / +260 C Voltage rating: 600 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: stranded nickel plated copper 2 - Insulation: extruded PTFE SAE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT E759/12-28 NPC M22759/ x E759/12-26 NPC M22759/ x E759/12-24 NPC M22759/ x E759/12-22 NPC M22759/ x E759/12-20 NPC M22759/ x E759/12-18 NPC M22759/ x E759/12-16 NPC M22759/ x E759/12-14 NPC M22759/ x E759/12-12 NPC M22759/ x E759/12-10 NPC M22759/ x E759/12-8 NPC M22759/ x

27 26-65 C / +200 C Single wires PTFE Extruded single wires ASTM-B-624 ASTM-D-4895 SAE-AS22759 Insulation: PTFE SAE-AS22759/22 Operating temperature: -65 C / +200 C Voltage rating: 600 Volts AC Standard multicores: see page Conductor: stranded silver plated high strength copper alloy 2 - Insulation: extruded PTFE SAE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) E759/22-28 SCA M22759/ x E759/22-26 SCA M22759/ x E759/22-24 SCA M22759/ x E759/22-22 SCA M22759/ x E759/22-20 SCA M22759/ x APPROX. WEIGHT

28 PTFE Single wires -65 C / +260 C 27 ASTM-B-624 ASTM-B-355 ASTM-D-4895 SAE-AS22759 Insulation: PTFE SAE-AS22759/23 Operating temperature: -65 C / +260 C Voltage rating: 600 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: stranded nickel plated high strength copper alloy 2 - Insulation: extruded PTFE SAE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) E759/23-28 NCA M22759/ x E759/23-26 NCA M22759/ x E759/23-24 NCA M22759/ x E759/23-22 NCA M22759/ x E759/23-20 NCA M22759/ x APPROX. WEIGHT

29 28-90 C / +200 C Miniature single wires FEP Extruded single wires ASTM-B-624 ASTM-D-2116 UKT xxxx SPC or SCA Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) UKT 3601 SCA 36 1x UKT 3607 SCA 36 7x UKT 3401 SCA 34 1x UKT 3407 SCA 34 7x UKT 3201 SCA 32 1x UKT 3207 SCA 32 7x UKT 3219 SCA 32 19x UKT 3001 SCA 30 1x UKT 3007 SCA 30 7x UKT 3019 SCA 30 19x UKT x UKT x UKT x APPROX. WEIGHT

30 FEP Single wires -90 C / +200 C 29 ASTM-B-624 ASTM-D-2116 NEMA-HP4 Insulation: FEP KT xxxx SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) KT 3601 SCA 36 1x KT 3607 SCA 36 7x KT 3401 SCA 34 1x KT 3407 SCA 34 7x KT 3201 HP4-KTBAA 32 1x KT x KT 3219 SCA 32 19x KT 3001 HP4-KTBBA 30 1x KT 3007 HP4-KTBBB 30 7x KT 3019 SCA 30 19x KT x KT 2807 HP4-KTBCB 28 7x KT x KT 2601 HP4-KTBDA 26 1x KT 2607 HP4-KTBDB 26 7x KT x KT 2401 HP4-KTBEA 24 1x KT 2407 HP4-KTBEB 24 7x KT x KT 2201 HP4-KTBFA 22 1x KT 2207 HP4-KTBFB 22 7x KT x KT 2001 HP4-KTBGA 20 1x KT 2007 HP4-KTBGB 20 7x KT x APPROX. WEIGHT

31 30-55 C / +150 C Single wires FEP Extruded single wires ASTM-B-33 ASTM-D-2116 Insulation: FEP Operating temperature: -55 C / +150 C Voltage rating: 250 Volts AC KT xxxx TPC Standard multicores: see page Conductor: tin plated annealed copper 2 - Insulation: extruded FEP AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) KT 2807 TPC 28 7x KT 2619 TPC 26 19x KT 2419 TPC 24 19x KT 2237 TPC 22 37x KT 2037 TPC 20 37x APPROX. WEIGHT

32 FEP -90 C / +200 C 31 Single wires ASTM-B-624 ASTM-D-2116 NEMA-HP4 Insulation: FEP K xxxx SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT K 3601 SCA 36 1x K 3607 SCA 36 7x K 3401 SCA 34 1x K 3407 SCA 34 7x K 3201 HP4-KBAA 32 1x K x K 3219 SCA 32 19x K 3001 HP4-KBBA 30 1x K 3007 HP4-KBBB 30 7x K 3019 SCA 30 19x K x K 2807 HP4-KBCB 28 7x K x K 2601 HP4-KBDA 26 1x K 2607 HP4-KBDB 26 7x K x K 2401 HP4-KBEA 24 1x K 2407 HP4-KBEB 24 7x K x K 2201 HP4-KBFA 22 1x K 2207 HP4-KBFB 22 7x K x K 2001 HP4-KBGA 20 1x K x K x K x K x K x K x K x K x K x According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

33 32-55C / +150C Single wires FEP Extruded single wires ASTM-B-33 ASTM-D-2116 Insulation: FEP Operating temperature: -55C / +150C Voltage rating: 600 Volts AC K xxxx TPC Standard multicores: see page Conductor: tin plated annealed copper 2 - Insulation: extruded FEP AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT K 2807 TPC 28 7x K 2619 TPC 26 19x K 2419 TPC 24 19x K 2237 TPC 22 37x K 2037 TPC 20 37x K 1861 TPC 18 61x K 1661 TPC 16 61x K 1461 TPC 14 61x K 1291 TPC 12 91x K 1091 TPC 10 91x K 8133 TPC 8 133x

34 FEP Single wires -90 C / +200 C 33 ASTM-B-624 ASTM-D-2116 NEMA-HP4 Insulation: FEP KK xxxx SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC Standard multicores: see page 6 Extruded single wires Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT KK x KK 3207 HP4-KKBAB 32 7x KK 3219 SCA 32 19x KK 3001 HP4-KKBBA 30 1x KK 3007 HP4-KKBBB 30 7x KK 3019 SCA 30 19x KK 2801 HP4-KKBCA 28 1x KK 2807 HP4-KKBCB 28 7x KK x KK 2601 HP4-KKBDA 26 1x KK 2607 HP4-KKBDB 26 7x KK 2619 HP4-KKBDE 26 19x KK 2401 HP4-KKBEA 24 1x KK 2407 HP4-KKBEB 24 7x KK 2419 HP4-KKBEE 24 19x KK 2201 HP4-KKBFA 22 1x KK 2207 HP4-KKBFB 22 7x KK 2219 HP4-KKBFE 22 19x KK 2001 HP4-KKBGA 20 1x KK 2007 HP4-KKBGB 20 7x KK 2019 HP4-KKBGE 20 19x KK 1819 HP4-KKBHE 18 19x KK x KK 1419 HP4-KKBKE 14 19x KK x KK 1219 HP4-KKBLE 12 19x KK x KK x KK 1037 HP4-KKBMG 10 37x KK 8133 HP4-KKBNL 8 133x KK 6133 HP4-KKBPL 6 133x KK 4133 HP4-KKBRL 4 133x KK 2665 HP4-KKBSP 2 665x According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

35 34-90 C / +155 C Single wires ETFE LIGHT WEIGHT Extruded single wires ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759/18 Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC ZL xxxx TPC Standard multicores: see page Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) ZL 3007 KU x ZL 2807 KU x ZL 2619 KU M22759/ x ZL 2419 KU M22759/ x ZL 2219 KU M22759/ x ZL 2019 M22759/ x ZL 1819 M22759/ x ZL x ZL 1419 M22759/ x ZL 1237 M22759/ x ZL 1037 M22759/ x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

36 ETFE -90 C / +155 C 35 Single wires MEDIUM WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759/16 Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC ZN xxxx TPC Standard multicores: see page 6 Extruded single wires Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT ZN x ZN x ZN x ZN 2419 M22759/ x ZN 2219 M22759/ x ZN 2019 KU M22759/ x ZN 1819 KU M22759/ x ZN 1619 KU x ZN 1419 M22759/ x ZN 1437 KU x ZN 1237 KU M22759/ x ZN 1037 M22759/ x ZN 8133 M22759/ x ZN 6133 M22759/ x ZN 4133 M22759/ x ZN 2665 M22759/ x ZN 1817 M22759/ x ZN M22759/ x ZN M22759/ x According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

37 36-90 C / +155 C Single wires ETFE Extruded single wires ASTM-B-33 ASTM-D-3159 Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 1000 Volts AC ZZ xxxx TPC Standard multicores: see page Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x ZZ x

38 ETFE -90 C / +155 C 37 Single wires MEDIUM WEIGHT ASTM-D-3159 Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC ZA xxxx SPC Extruded single wires Standard multicores: see page Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded ETFE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x ZA x

39 38-90 C / +155 C Single wires ETFE LIGHT WEIGHT Extruded single wires ASTM-D-3159 Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC ZLA xxxx SPC Standard multicores: see page Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded ETFE AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT ZLA x ZLA x ZLA x ZLA x ZLA x ZLA x ZLA x ZLA x

40 39 Taped single wires Axon has a large expertise in manufacturing taped single wires. They offer more fl exibility and can be insulated with: - PTFE tapes - or Polyimide tapes to withstand temperatures from -90 C up to 200 C.

41

42 PTFE TAPE Single wires -90 C / +200 C 41 Insulation: PTFE tape RET xxxx SPC Operating temperature: -90 C / +200 C ASTM-D-4895 NF-C-93523/4 NEMA-HP3 Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Taped single wires 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) RET 3207 KZ x RET 3007 KZ HP3-ETWBBB 30 7x RET x RET 2807 KZ HP3-ETWBCB 28 7x RET x RET 2607 KZ HP3-ETWBDB 26 7x RET x RET x RET 2407 KZ HP3-ETWBEB 24 7x RET x RET x RET 2207 KZ HP3-ETWBFB 22 7x RET x RET x RET 2019 KZ x RET x RET x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

43 42-90 C / +200 C Single wires PTFE TAPE Insulation: PTFE tape RE xxxx SPC Operating temperature: -90 C / +200 C Taped single wires ASTM-D-4895 NF-C-93523/5 NEMA-HP3 Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) RE 3207 KZ x RE 3007 KZ HP3-EWBBB 30 7x RE 2807 KZ HP3-EWBCB 28 7x RE x RE 2607 KZ HP3-EWBDB 26 7x RE x RE x RE 2407 KZ HP3-EWBEB 24 7x RE x RE x RE 2207 KZ HP3-EWBFB 22 7x RE x RE x RE 2019 KZ x RE x RE 1819 KZ x RE 1619 KZ x RE x RE x RE x RE 1427 KZ x RE x RE 1245 KZ x RE x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

44 PTFE TAPE Single wires -90 C / +200 C 43 Insulation: PTFE tape REE xxxx SPC Operating temperature: -90 C / +200 C ASTM-D-4895 NF-C-93523/6 NEMA-HP3 Voltage rating: 1000 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Taped single wires 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) REE 3207 KZ HP3-EEWBAB 32 7x REE 3007 KZ HP3-EEWBBB 30 7x REE 2807 KZ HP3-EEWBCB 28 7x REE x REE 2607 KZ HP3-EEWBDB 26 7x REE 2619 HP3-EEWBDE 26 19x REE 2407 KZ HP3-EEWBEB 24 7x REE 2419 HP3-EEWBEE 24 19x REE 2207 KZ HP3-EEWBFB 22 7x REE 2219 HP3-EEWBFE 22 19x REE 2019 KZ HP3-EEWBGE 20 19x REE 1819 KZ HP3-EEWBHE 18 19x REE 1619 KZ x REE x REE 1427 KZ x REE x REE 1245 KZ x REE 1037 HP3-EEWBMG 10 37x REE 8133 HP3-EEWBNL 8 133x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

45 44-90 C / +260 C Single wires PTFE TAPE ASTM-B-355 Insulation: PTFE tape RET xxxx NPC Operating temperature: -90 C / +260 C Taped single wires ASTM-D-4895 NEMA-HP3 Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: electrolytic nickel plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) RET 3207 NPC 32 7x RET 3007 NPC HP3-ETWCBB 30 7x RET 2807 NPC HP3-ETWCCB 28 7x RET 2819 NPC 28 19x RET 2607 NPC HP3-ETWCDB 26 7x RET 2619 NPC 26 19x RET 2407 NPC HP3-ETWCEB 24 7x RET 2419 NPC 24 19x RET 2207 NPC HP3-ETWCFB 22 7x RET 2219 NPC 22 19x RET 2019 NPC 20 19x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

46 PTFE TAPE Single wires -90 C / +260 C 45 ASTM-B-355 Insulation: PTFE tape RE xxxx NPC Operating temperature: -90 C / +260 C ASTM-D-4895 NEMA-HP3 Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Taped single wires 1 - Conductor: electrolytic nickel plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) RE 3207 NPC 32 7x RE 3007 NPC HP3-EWCBB 30 7x RE 2807 NPC HP3-EWCCB 28 7x RE 2819 NPC 28 19x RE 2607 NPC HP3-EWCDB 26 7x RE 2619 NPC 26 19x RE 2407 NPC HP3-EWCEB 24 7x RE 2419 NPC 24 19x RE 2207 NPC HP3-EWCFB 22 7x RE 2219 NPC 22 19x RE 2019 NPC 20 19x RE 1819 NPC 18 19x RE 1619 NPC 16 19x RE 1419 NPC 14 19x RE 1427 NPC 14 27x RE 1219 NPC 12 19x RE 1245 NPC 12 45x RE 1037 NPC 10 37x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

47 46-90 C / +260 C Single wires PTFE TAPE ASTM-B-355 Insulation: PTFE tape REE xxxx NPC Operating temperature: -90 C / +260 C Taped single wires ASTM-D-4895 NEMA-HP3 Voltage rating: 1000 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: electrolytic nickel plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) REE 3207 NPC HP3-EEWCAB 32 7x REE 3007 NPC HP3-EEWCBB 30 7x REE 2807 NPC HP3-EEWCCB 28 7x REE 2819 NPC 28 19x REE 2607 NPC HP3-EEWCDB 26 7x REE 2619 NPC HP3-EEWCDE 26 19x REE 2407 NPC HP3-EEWCEB 24 7x REE 2419 NPC HP3-EEWCEE 24 19x REE 2207 NPC HP3-EEWCFB 22 7x REE 2219 NPC HP3-EEWCFE 22 19x REE 2019 NPC HP3-EEWCGE 20 19x REE 1819 NPC HP3-EEWCHE 18 19x REE 1619 NPC 16 19x REE 1419 NPC 14 19x REE 1427 NPC 14 27x REE 1219 NPC 12 19x REE 1245 NPC 12 45x REE 1037 NPC HP3-EEWCMG 10 37x APPROX. WEIGHT According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

48 POLYIMIDE TAPE -90 C / +200 C 47 Single wires LIGHT WEIGHT ASTM-B-624 HT xxxx SPC or SCA Insulation: Polyimide tape Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Taped single wires 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: wrapped and sealed Polyimide tape and fl uoropolymer top coating for colouring AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) HT 3001 SCA 30 1x HT 3007 SCA 30 7x HT 2801 SCA 28 1x HT 2807 SCA 28 7x HT x HT x HT x HT x HT x HT x HT x HT x HT x HT x APPROX. WEIGHT

49 48-90 C / +200 C Single wires POLYIMIDE TAPE MEDIUM WEIGHT ASTM-B-624 H xxxx SPC or SCA Insulation: Polyimide tape Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Taped single wires Standard multicores: see page Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: wrapped and sealed Polyimide tape and fl uoropolymer top coating for colouring AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT H 3001 SCA 30 1x H 3007 SCA 30 7x H 2801 SCA 28 1x H 2807 SCA 28 7x H x H x H x H x H x H x H x H x H x H x H x H x H x H x H x H x H x

50 POLYIMIDE AND PTFE TAPE -90 C / +200 C 49 Single wires Insulation: Polyimide / PTFE tape HET xxxx SPC Operating temperature: -90 C / +200 C Voltage rating: 300 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Taped single wires 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: wrapped and sealed Polyimide and PTFE tape AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT HET x HET x HET x HET x HET x

51 50-90 C / +200 C POLYIMIDE AND PTFE TAPE Single wires Insulation: Polyimide / PTFE tape HE xxxx SPC Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Taped single wires Standard multicores: see page Conductor: electrolytic silver plated annealed copper 2 - Insulation: wrapped and sealed Polyimide and PTFE tape AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT HE x HE x HE x HE x

52 Shielded wires & cables 51 Axon offers a range of shielded cables which can withstand temperatures from -90 C to +200 C. It provides the same electrical potential in the cable assembly. The braided shield is made from electrolytic silver annealed copper. Single core, twisted pairs, twisted triples and twisted quads versions are available.

53

54 PTFE -90 C / +200 C 53 Shielded single core cables ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE ET xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT ET 3601 S1 ET 3601 SCA ET 3607 S1 ET 3607 SCA ET 3401 S1 ET 3401 SCA ET 3407 S1 ET 3407 SCA ET 3201 S1 ET (R) ET 3207 S1 (R) ET (R) ET 3001 S1 (R) ET (R) ET 3007 S1 (R) ET (R) ET 3019 S1 (R) ET 3019 SCA (R) ET 2801 S1 (R) ET (R) ET 2807 S1 (R) ET (R) ET 2819 S1 (R) ET (R) ET 2601 S1 (R) ET (R) ET 2607 S1 (R) ET (R) ET 2619 S1 (R) ET (R) ET 2401 S1 (R) ET (R) ET 2407 S1 (R) ET (R) ET 2419 S1 (R) ET (R) ET 2201 S1 (R) ET (R) ET 2207 S1 (R) ET (R) ET 2219 S1 (R) ET (R) ET 2001 S1 (R) ET (R) ET 2007 S1 (R) ET (R) ET 2019 S1 (R) ET

55 54-90 C / +200 C Shielded twisted pairs PTFE ET xxxx S2 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT ET 3601 S2 ET 3601 SCA ET 3607 S2 ET 3607 SCA ET 3401 S2 ET 3401 SCA ET 3407 S2 ET 3407 SCA ET 3201 S2 ET (R) ET 3207 S2 (R) ET (R) ET 3001 S2 (R) ET (R) ET 3007 S2 (R) ET (R) ET 3019 S2 (R) ET 3019 SCA (R) ET 2801 S2 (R) ET (R) ET 2807 S2 (R) ET (R) ET 2819 S2 (R) ET (R) ET 2601 S2 (R) ET (R) ET 2607 S2 (R) ET (R) ET 2619 S2 (R) ET (R) ET 2401 S2 (R) ET (R) ET 2407 S2 (R) ET (R) ET 2419 S2 (R) ET (R) ET 2201 S2 (R) ET (R) ET 2207 S2 (R) ET (R) ET 2219 S2 (R) ET (R) ET 2001 S2 (R) ET (R) ET 2007 S2 (R) ET (R) ET 2019 S2 (R) ET

56 PTFE Shielded twisted triples -90 C / +200 C 55 ET xxxx S3 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT ET 3601 S3 ET 3601 SCA ET 3607 S3 ET 3607 SCA ET 3401 S3 ET 3401 SCA ET 3407 S3 ET 3407 SCA ET 3201 S3 ET (R) ET 3207 S3 (R) ET (R) ET 3001 S3 (R) ET (R) ET 3007 S3 (R) ET (R) ET 3019 S3 (R) ET 3019 SCA (R) ET 2801 S3 (R) ET (R) ET 2807 S3 (R) ET (R) ET 2819 S3 (R) ET (R) ET 2601 S3 (R) ET (R) ET 2607 S3 (R) ET (R) ET 2619 S3 (R) ET (R) ET 2401 S3 (R) ET (R) ET 2407 S3 (R) ET (R) ET 2419 S3 (R) ET (R) ET 2201 S3 (R) ET (R) ET 2207 S3 (R) ET (R) ET 2219 S3 (R) ET (R) ET 2001 S3 (R) ET (R) ET 2007 S3 (R) ET (R) ET 2019 S3 (R) ET

57 56-90 C / +200 C Shielded twisted quads PTFE ET xxxx S4 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT ET 3601 S4 ET 3601 SCA ET 3607 S4 ET 3607 SCA ET 3401 S4 ET 3401 SCA ET 3407 S4 ET 3407 SCA ET 3201 S4 ET (R) ET 3207 S4 (R) ET (R) ET 3001 S4 (R) ET (R) ET 3007 S4 (R) ET (R) ET 3019 S4 (R) ET 3019 SCA (R) ET 2801 S4 (R) ET (R) ET 2807 S4 (R) ET (R) ET 2819 S4 (R) ET (R) ET 2601 S4 (R) ET (R) ET 2607 S4 (R) ET (R) ET 2619 S4 (R) ET (R) ET 2401 S4 (R) ET (R) ET 2407 S4 (R) ET (R) ET 2419 S4 (R) ET (R) ET 2201 S4 (R) ET (R) ET 2207 S4 (R) ET (R) ET 2219 S4 (R) ET (R) ET 2001 S4 (R) ET (R) ET 2007 S4 (R) ET (R) ET 2019 S4 (R) ET

58 PTFE -90 C / +200 C 57 Shielded single core cables ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 54, ET xxxx H S1 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (REE) on request PROTECTION 3 - Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables NF (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT (R) ET 2607 H S1 KZ KZ (R) ET 2407 H S1 KZ KZ (R) ET 2207 H S1 KZ KZ (R) ET 2019 H S1 KZ KZ

59 58-90 C / +200 C Shielded twisted pairs PTFE ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 66, ET xxxx H S2 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request PROTECTION 3 - Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper NF (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT (R) ET 3207 H S2 KZ KZ (R) ET 3007 H S2 KZ KZ (R) ET 2807 H S2 KZ KZ (R) ET 2607 H S2 KZ KZ (R) ET 2407 H S2 KZ KZ (R) ET 2207 H S2 KZ KZ (R) ET 2019 H S2 KZ KZ

60 PTFE Shielded twisted triples -90 C / +200 C 59 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 78, ET xxxx H S3 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (ET) Wrapped and sintered PTFE tape (RET) on request PROTECTION 3 - Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables NF (see pages 18, 41) SHIELDED CABLE OUTER APPROX. WEIGHT (R) ET 3207 H S3 KZ KZ (R) ET 3007 H S3 KZ KZ (R) ET 2807 H S3 KZ KZ (R) ET 2607 H S3 KZ KZ (R) ET 2407 H S3 KZ KZ (R) ET 2207 H S3 KZ KZ (R) ET 2019 H S3 KZ KZ

61 60-90 C / +200 C Shielded single core cables PTFE ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE E xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT E 3407 S1 E 3407 SCA (R) E 3207 S1 (R) E (R) E 3007 S1 (R) E (R) E 2807 S1 (R) E (R) E 2607 S1 (R) E (R) E 2619 S1 (R) E (R) E 2407 S1 (R) E (R) E 2419 S1 (R) E (R) E 2207 S1 (R) E (R) E 2219 S1 (R) E (R) E 2007 S1 (R) E (R) E 2019 S1 (R) E (R) E 1819 S1 (R) E (R) E 1619 S1 (R) E (R) E 1419 S1 (R) E (R) E 1219 S1 (R) E RE 1037 S1 RE

62 PTFE -90 C / +200 C 61 Shielded single core cables ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 56, E xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ56-08 KZ or (R)E KZ56-09 KZ or (R)E KZ KZ or RE KZ KZ or RE

63 62-90 C / +200 C Shielded twisted pairs PTFE E xxxx S2 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT E 3407 S2 E 3407 SCA (R) E 3207 S2 (R) E (R) E 3007 S2 (R) E (R) E 2807 S2 (R) E (R) E 2607 S2 (R) E (R) E 2619 S2 (R) E (R) E 2407 S2 (R) E (R) E 2419 S2 (R) E (R) E 2207 S2 (R) E (R) E 2219 S2 (R) E (R) E 2007 S2 (R) E (R) E 2019 S2 (R) E (R) E 1819 S2 (R) E (R) E 1619 S2 (R) E (R) E 1419 S2 (R) E (R) E 1219 S2 (R) E RE 1037 S2 RE

64 PTFE Shielded twisted pairs -90 C / +200 C 63 KZ 68, E xxxx S2 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E

65 64-90 C / +200 C Shielded twisted triples PTFE E xxxx S3 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT E 3407 S3 E 3407 SCA (R) E 3207 S3 (R) E (R) E 3007 S3 (R) E (R) E 2807 S3 (R) E (R) E 2607 S3 (R) E (R) E 2619 S3 (R) E (R) E 2407 S3 (R) E (R) E 2419 S3 (R) E (R) E 2207 S3 (R) E (R) E 2219 S3 (R) E (R) E 2007 S3 (R) E (R) E 2019 S3 (R) E (R) E 1819 S3 (R) E (R) E 1619 S3 (R) E (R) E 1419 S3 (R) E (R) E 1219 S3 (R) E RE 1037 S3 RE

66 PTFE Shielded twisted triples -90 C / +200 C 65 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 80, E xxxx S3 Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E KZ KZ or (R)E

67 66-90 C / +200 C Shielded twisted quads PTFE E xxxx S4 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (E) Wrapped and sintered PTFE tape (RE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 19, 42) SHIELDED CABLE OUTER APPROX. WEIGHT E 3407 S4 E 3407 SCA (R) E 3207 S4 (R) E (R) E 3007 S4 (R) E (R) E 2807 S4 (R) E (R) E 2607 S4 (R) E (R) E 2619 S4 (R) E (R) E 2407 S4 (R) E (R) E 2419 S4 (R) E (R) E 2207 S4 (R) E (R) E 2219 S4 (R) E (R) E 2007 S4 (R) E (R) E 2019 S4 (R) E (R) E 1819 S4 (R) E (R) E 1619 S4 (R) E (R) E 1419 S4 (R) E (R) E 1219 S4 (R) E RE 1037 S4 RE

68 PTFE -90 C / +200 C 67 Shielded single core cables ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE EE xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT (R) EE 3207 S1 (R) EE (R) EE 3007 S1 (R) EE (R) EE 2807 S1 (R) EE (R) EE 2607 S1 (R) EE (R) EE 2619 S1 (R) EE (R) EE 2407 S1 (R) EE (R) EE 2419 S1 (R) EE (R) EE 2207 S1 (R) EE (R) EE 2219 S1 (R) EE (R) EE 2007 S1 (R) EE (R) EE 2019 S1 (R) EE (R) EE 1819 S1 (R) EE (R) EE 1619 S1 (R) EE (R) EE 1419 S1 (R) EE (R) EE 1219 S1 (R) EE REE 1037 S1 REE

69 68-90 C / +200 C Shielded single core cables PTFE ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 58, EE xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or REE KZ KZ or REE

70 PTFE Shielded twisted pairs -90 C / +200 C 69 EE xxxx S2 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT (R) EE 3207 S2 (R) EE (R) EE 3007 S2 (R) EE (R) EE 2807 S2 (R) EE (R) EE 2607 S2 (R) EE (R) EE 2619 S2 (R) EE (R) EE 2407 S2 (R) EE (R) EE 2419 S2 (R) EE (R) EE 2207 S2 (R) EE (R) EE 2219 S2 (R) EE (R) EE 2007 S2 (R) EE (R) EE 2019 S2 (R) EE (R) EE 1819 S2 (R) EE (R) EE 1619 S2 (R) EE (R) EE 1419 S2 (R) EE (R) EE 1219 S2 (R) EE REE 1037 S2 REE

71 70-90 C / +200 C Shielded twisted pairs PTFE ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 70, EE xxxx S2 Operating temperature: -90 C / +200 C Voltage rating: Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or REE KZ KZ or REE

72 PTFE Shielded twisted triples -90 C / +200 C 71 EE xxxx S3 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT (R) EE 3207 S3 (R) EE (R) EE 3007 S3 (R) EE (R) EE 2807 S3 (R) EE (R) EE 2607 S3 (R) EE (R) EE 2619 S3 (R) EE (R) EE 2407 S3 (R) EE (R) EE 2419 S3 (R) EE (R) EE 2207 S3 (R) EE (R) EE 2219 S3 (R) EE (R) EE 2007 S3 (R) EE (R) EE 2019 S3 (R) EE (R) EE 1819 S3 (R) EE (R) EE 1619 S3 (R) EE (R) EE 1419 S3 (R) EE (R) EE 1219 S3 (R) EE REE 1037 S3 REE

73 72-90 C / +200 C Shielded twisted triples PTFE ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE KZ 82, EE xxxx S3 Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or (R)EE KZ KZ or REE KZ KZ or REE

74 PTFE Shielded twisted quads -90 C / +200 C 73 EE xxxx S4 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE (EE) Wrapped and sintered PTFE tape (REE) on request 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see pages 20, 43) SHIELDED CABLE OUTER APPROX. WEIGHT (R) EE 3207 S4 (R) EE (R) EE 3007 S4 (R) EE (R) EE 2807 S4 (R) EE (R) EE 2607 S4 (R) EE (R) EE 2619 S4 (R) EE (R) EE 2407 S4 (R) EE (R) EE 2419 S4 (R) EE (R) EE 2207 S4 (R) EE (R) EE 2219 S4 (R) EE (R) EE 2007 S4 (R) EE (R) EE 2019 S4 (R) EE (R) EE 1819 S4 (R) EE (R) EE 1619 S4 (R) EE (R) EE 1419 S4 (R) EE (R) EE 1219 S4 (R) EE REE 1037 S4 REE

75 74-90 C / +200 C Shielded single core cables FEP ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP KT xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper (see page 29) SHIELDED CABLE OUTER APPROX. WEIGHT KT 3601 S1 KT 3601 SCA KT 3607 S1 KT 3607 SCA KT 3401 S1 KT 3401 SCA KT 3407 S1 KT 3407 SCA KT 3201 S1 KT KT 3207 S1 KT KT 3001 S1 KT KT 3007 S1 KT KT 3019 S1 KT 3019 SCA KT 2801 S1 KT KT 2807 S1 KT KT 2819 S1 KT KT 2601 S1 KT KT 2607 S1 KT KT 2619 S1 KT KT 2401 S1 KT KT 2407 S1 KT KT 2419 S1 KT KT 2201 S1 KT KT 2207 S1 KT KT 2219 S1 KT KT 2001 S1 KT KT 2007 S1 KT KT 2019 S1 KT

76 FEP Shielded twisted pairs -90 C / +200 C 75 KT xxxx S2 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see page 29) SHIELDED CABLE OUTER APPROX. WEIGHT KT 3601 S2 KT 3601 SCA KT 3607 S2 KT 3607 SCA KT 3401 S2 KT 3401 SCA KT 3407 S2 KT 3407 SCA KT 3201 S2 KT KT 3207 S2 KT KT 3001 S2 KT KT 3007 S2 KT KT 3019 S2 KT 3019 SCA KT 2801 S2 KT KT 2807 S2 KT KT 2819 S2 KT KT 2601 S2 KT KT 2607 S2 KT KT 2619 S2 KT KT 2401 S2 KT KT 2407 S2 KT KT 2419 S2 KT KT 2201 S2 KT KT 2207 S2 KT KT 2219 S2 KT KT 2001 S2 KT KT 2007 S2 KT KT 2019 S2 KT

77 76-90 C / +200 C Shielded twisted triples FEP ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP KT xxxx S3 Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper (see page 29) SHIELDED CABLE OUTER APPROX. WEIGHT KT 3601 S3 KT 3601 SCA KT 3607 S3 KT 3607 SCA KT 3401 S3 KT 3401 SCA KT 3407 S3 KT 3407 SCA KT 3201 S3 KT KT 3207 S3 KT KT 3001 S3 KT KT 3007 S3 KT KT 3019 S3 KT 3019 SCA KT 2801 S3 KT KT 2807 S3 KT KT 2819 S3 KT KT 2601 S3 KT KT 2607 S3 KT KT 2619 S3 KT KT 2401 S3 KT KT 2407 S3 KT KT 2419 S3 KT KT 2201 S3 KT KT 2207 S3 KT KT 2219 S3 KT KT 2001 S3 KT KT 2007 S3 KT KT 2019 S3 KT

78 FEP -90 C / +200 C 77 Shielded single core cables ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP K xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see page 31) SHIELDED CABLE OUTER APPROX. WEIGHT K 3407 S1 K 3407 SCA K 3207 S1 K K 3007 S1 K K 2807 S1 K K 2607 S1 K K 2619 S1 K K 2407 S1 K K 2419 S1 K K 2207 S1 K K 2219 S1 K K 2007 S1 K K 2019 S1 K K 1819 S1 K K 1619 S1 K K 1419 S1 K K 1219 S1 K K 1037 S1 K

79 78-90 C / +200 C Shielded twisted pairs FEP ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP K xxxx S2 Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper (see page 31) SHIELDED CABLE OUTER APPROX. WEIGHT K 3407 S2 K 3407 SCA K 3207 S2 K K 3007 S2 K K 2807 S2 K K 2607 S2 K K 2619 S2 K K 2407 S2 K K 2419 S2 K K 2207 S2 K K 2219 S2 K K 2007 S2 K K 2019 S2 K K 1819 S2 K K 1619 S2 K K 1419 S2 K K 1219 S2 K K 1037 S2 K

80 FEP Shielded twisted triples -90 C / +200 C 79 K xxxx S3 ASTM-B-694 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see page 31) SHIELDED CABLE OUTER APPROX. WEIGHT K 3407 S3 K 3407 SCA K 3207 S3 K K 3007 S3 K K 2807 S3 K K 2607 S3 K K 2619 S3 K K 2407 S3 K K 2419 S3 K K 2207 S3 K K 2219 S3 K K 2007 S3 K K 2019 S3 K K 1819 S3 K K 1619 S3 K K 1419 S3 K K 1219 S3 K K 1037 S3 K

81 80-90 C / +200 C Shielded single core cables FEP ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP KK xxxx S1 Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper (see page 33) SHIELDED CABLE OUTER APPROX. WEIGHT KK 3207 S1 KK KK 3007 S1 KK KK 2807 S1 KK KK 2607 S1 KK KK 2619 S1 KK KK 2407 S1 KK KK 2419 S1 KK KK 2207 S1 KK KK 2219 S1 KK KK 2007 S1 KK KK 2019 S1 KK KK 1819 S1 KK KK 1619 S1 KK KK 1419 S1 KK KK 1219 S1 KK KK 1037 S1 KK

82 FEP Shielded twisted pairs -90 C / +200 C 81 KK xxxx S2 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper Shielded wires & cables (see page 33) SHIELDED CABLE OUTER APPROX. WEIGHT KK 3207 S2 KK KK 3007 S2 KK KK 2807 S2 KK KK 2607 S2 KK KK 2619 S2 KK KK 2407 S2 KK KK 2419 S2 KK KK 2207 S2 KK KK 2219 S2 KK KK 2007 S2 KK KK 2019 S2 KK KK 1819 S2 KK KK 1619 S2 KK KK 1419 S2 KK KK 1219 S2 KK KK 1037 S2 KK

83 82-90 C / +200 C Shielded twisted triples FEP KK xxxx S3 ASTM-D-2116 ASTM-D-4895 NEMA-HP3 NF-C Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded wires & cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper (see page 33) SHIELDED CABLE OUTER APPROX. WEIGHT KK 3207 S3 KK KK 3007 S3 KK KK 2807 S3 KK KK 2607 S3 KK KK 2619 S3 KK KK 2407 S3 KK KK 2419 S3 KK KK 2207 S3 KK KK 2219 S3 KK KK 2007 S3 KK KK 2019 S3 KK KK 1819 S3 KK KK 1619 S3 KK KK 1419 S3 KK KK 1219 S3 KK KK 1037 S3 KK

84 Shielded and jacketed cables 83 The primary insulation of the shielded and jacketed cables manufactured by Axon can be made from: PTFE to withstand -90 C to +200 C FEP to withstand -90 C to +200 C ETFE to withstand -90 C to +155 C The braided shield is made from tin plated annealed copper or electrolytic silver annealed copper. The jacket is made from FEP or ETFE material.

85

86 PTFE / FEP -90 C / +200 C 85 Shielded jacketed single core cables AND JACKET ASTM-D-2116 ASTM-D-4895 ASTM-B-624 UT xxxx STK 1 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA). 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 17) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT UT 3607 SCA STK1 UT 3607 SCA UT 3407 SCA STK1 UT 3407 SCA UT 3207 SCA STK1 UT 3207 SCA UT 3007 SCA STK1 UT 3007 SCA UT 2807 STK1 UT

87 86-90 C / +200 C Shielded jacketed twisted pairs PTFE / FEP AND JACKET ASTM-D-2116 ASTM-D-4895 ASTM-B-624 UT xxxx STK 2 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 17) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT UT 3607 SCA STK2 UT 3607 SCA UT 3407 SCA STK2 UT 3407 SCA UT 3207 SCA STK2 UT 3207 SCA UT 3007 SCA STK2 UT 3007 SCA UT 2807 STK2 UT

88 PTFE / FEP -90 C / +200 C 87 Shielded jacketed twisted triples AND JACKET ASTM-D-2116 ASTM-D-4895 ASTM-B-624 UT xxxx STK 3 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 17) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT UT 3607 SCA STK3 UT 3607 SCA UT 3407 SCA STK3 UT 3407 SCA UT 3207 SCA STK3 UT 3207 SCA UT 3007 SCA STK3 UT 3007 SCA UT 2807 STK3 UT

89 88-90 C / +200 C Shielded jacketed twisted quads PTFE / FEP AND JACKET ASTM-D-2116 ASTM-D-4895 ASTM-B-624 UT xxxx STK 4 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 160 Volts AC Standard colours: see page 6. Other colours Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 17) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT UT 3607 SCA STK4 UT 3607 SCA UT 3407 SCA STK4 UT 3407 SCA UT 3207 SCA STK4 UT 3207 SCA UT 3007 SCA STK4 UT 3007 SCA UT 2807 STK4 UT

90 PTFE / FEP -90 C / +200 C 89 Shielded jacketed single core cables ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 ET xxxx STK 1 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 18) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ET 3601 STK1 ET 3601 SCA ET 3607 STK1 ET 3607 SCA ET 3401 STK1 ET 3401 SCA ET 3407 STK1 ET 3407 SCA ET 3201 STK1 ET ET 3207 STK1 ET 3207 or KZ ET 3001 STK1 ET ET 3007 STK1 ET 3007 or KZ ET 3019 STK1 ET 3019 SCA ET 2801 STK1 ET ET 2807 STK1 ET 2807 or KZ ET 2819 STK1 ET ET 2601 STK1 ET ET 2607 STK1 ET 2607 or KZ ET 2619 STK1 ET ET 2401 STK1 ET ET 2407 STK1 ET 2407 or KZ ET 2419 STK1 ET ET 2201 STK1 ET ET 2207 STK1 ET 2207 or KZ ET 2219 STK1 ET ET 2001 STK1 ET ET 2007 STK1 ET ET 2019 STK1 ET 2019 or KZ

91 90-90 C / +200 C Shielded jacketed twisted pairs PTFE / FEP ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 ET xxxx STK 2 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 18) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ET 3601 STK2 ET 3601 SCA ET 3607 STK2 ET 3607 SCA ET 3401 STK2 ET 3401 SCA ET 3407 STK2 ET 3407 SCA ET 3201 STK2 ET ET 3207 STK2 ET 3207 or KZ ET 3001 STK2 ET ET 3007 STK2 ET 3007 or KZ ET 3019 STK2 ET 3019 SCA ET 2801 STK2 ET ET 2807 STK2 ET 2807 or KZ ET 2819 STK2 ET ET 2601 STK2 ET ET 2607 STK2 ET 2607 or KZ ET 2619 STK2 ET ET 2401 STK2 ET ET 2407 STK2 ET 2407 or KZ ET 2419 STK2 ET ET 2201 STK2 ET ET 2207 STK2 ET 2207 or KZ ET 2219 STK2 ET ET 2001 STK2 ET ET 2007 STK2 ET ET 2019 STK2 ET 2019 or KZ

92 PTFE / FEP -90 C / +200 C 91 Shielded jacketed twisted triples ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 ET xxxx STK 3 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 18) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ET 3601 STK3 ET 3601 SCA ET 3607 STK3 ET 3607 SCA ET 3401 STK3 ET 3401 SCA ET 3407 STK3 ET 3407 SCA ET 3201 STK3 ET ET 3207 STK3 ET 3207 or KZ ET 3001 STK3 ET ET 3007 STK3 ET 3007 or KZ ET 3019 STK3 ET 3019 SCA ET 2801 STK3 ET ET 2807 STK3 ET 2807 or KZ ET 2819 STK3 ET ET 2601 STK3 ET ET 2607 STK3 ET 2607 or KZ ET 2619 STK3 ET ET 2401 STK3 ET ET 2407 STK3 ET 2407 or KZ ET 2419 STK3 ET ET 2201 STK3 ET ET 2207 STK3 ET 2207 or KZ ET 2219 STK3 ET ET 2001 STK3 ET ET 2007 STK3 ET ET 2019 STK3 ET 2019 or KZ

93 92-90 C / +200 C Shielded jacketed twisted quads PTFE / FEP ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 ET xxxx STK 4 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 18) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ET 3601 STK4 ET 3601 SCA ET 3607 STK4 ET 3607 SCA ET 3401 STK4 ET 3401 SCA ET 3407 STK4 ET 3407 SCA ET 3201 STK4 ET ET 3207 STK4 ET 3207 or KZ ET 3001 STK4 ET ET 3007 STK4 ET 3007 or KZ ET 3019 STK4 ET 3019 SCA ET 2801 STK4 ET ET 2807 STK4 ET 2807 or KZ ET 2819 STK4 ET ET 2601 STK4 ET ET 2607 STK4 ET 2607 or KZ ET 2619 STK4 ET ET 2401 STK4 ET ET 2407 STK4 ET 2407 or KZ ET 2419 STK4 ET ET 2201 STK4 ET ET 2207 STK4 ET 2207 or KZ ET 2219 STK4 ET ET 2001 STK4 ET ET 2007 STK4 ET ET 2019 STK4 ET 2019 or KZ

94 PTFE / FEP -90 C / +200 C 93 Shielded jacketed single core cables ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP E xxxx STK 1 SPC or SCA Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT E 3407 STK1 E 3407 SCA E 3207 STK1 E 3207 or KZ E 3007 STK1 E 3007 or KZ E 2807 STK1 E 2807 or KZ E 2607 STK1 E 2607 or KZ E 2619 STK1 E E 2407 STK1 E 2407 or KZ E 2419 STK1 E E 2207 STK1 E 2207 or KZ E 2219 STK1 E E 2007 STK1 E E 2019 STK1 E 2019 or KZ E 1819 STK1 E 1819 or KZ E 1619 STK1 E 1619 or KZ E 1419 STK1 E E 1219 STK1 E

95 94-90 C / +200 C Shielded jacketed twisted pairs PTFE / FEP ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 E xxxx STK 2 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT E 3407 STK2 E 3407 SCA E 3207 STK2 E 3207 or KZ E 3007 STK2 E 3207 or KZ E 2807 STK2 E 2807 or KZ E 2607 STK2 E 2607 or KZ E 2619 STK2 E E 2407 STK2 E 2407 or KZ E 2419 STK2 E E 2207 STK2 E 2207 or KZ E 2219 STK2 E E 2007 STK2 E E 2019 STK2 E 2019 or KZ E 1819 STK2 E 1819 or KZ E 1619 STK2 E 1619 or KZ E 1419 STK2 E E 1219 STK2 E

96 PTFE / FEP -90 C / +200 C 95 Shielded jacketed twisted triples ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 E xxxx STK 3 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT E 3407 STK3 E 3407 SCA E 3207 STK3 E 3207 or KZ E 3007 STK3 E 3007 or KZ E 2807 STK3 E 2807 or KZ E 2607 STK3 E 2607 or KZ E 2619 STK3 E E 2407 STK3 E 2407 or KZ E 2419 STK3 E E 2207 STK3 E 2207 or KZ E 2219 STK3 E E 2007 STK3 E E 2019 STK3 E 2019 or KZ E 1819 STK3 E 1819 or KZ E 1619 STK3 E 1619 or KZ E 1419 STK3 E E 1219 STK3 E

97 96-90 C / +200 C Shielded jacketed twisted quads PTFE / FEP ASTM-B-624 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 E xxxx STK 4 SPC or SCA Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT E 3407 STK4 E 3407 SCA E 3207 STK4 E 3207 or KZ E 3007 STK4 E 3007 or KZ E 2807 STK4 E 2807 or KZ E 2607 STK4 E 2607 or KZ E 2619 STK4 E E 2407 STK4 E 2407 or KZ E 2419 STK4 E E 2207 STK4 E 2207 or KZ E 2219 STK4 E E 2007 STK4 E E 2019 STK4 E 2019 or KZ E 1819 STK4 E 1819 or KZ E 1619 STK4 E 1619 or KZ E 1419 STK4 E E 1219 STK4 E

98 PTFE / FEP -90 C / +200 C 97 Shielded jacketed single core cables ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP EE xxxx STK 1 SPC Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT EE 3207 STK1 EE 3207 or KZ EE 3007 STK1 EE 3007 or KZ EE 2807 STK1 EE 2807 or KZ EE 2607 STK1 EE 2607 or KZ EE 2619 STK1 EE EE 2407 STK1 EE 2407 or KZ EE 2419 STK1 EE EE 2207 STK1 EE 2207 or KZ EE 2219 STK1 EE EE 2007 STK1 EE EE 2019 STK1 EE 2019 or KZ EE 1819 STK1 EE 1819 or KZ EE 1619 STK1 EE 1619 or KZ EE 1419 STK1 EE EE 1219 STK1 EE

99 98-90 C / +200 C Shielded jacketed twisted pairs PTFE / FEP ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP EE xxxx STK 2 SPC Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT EE 3207 STK2 EE 3207 or KZ EE 3007 STK2 EE 3007 or KZ EE 2807 STK2 EE 2807 or KZ EE 2607 STK2 EE 2607 or KZ EE 2619 STK2 EE EE 2407 STK2 EE 2407 or KZ EE 2419 STK2 EE EE 2207 STK2 EE 2207 or KZ EE 2219 STK2 EE EE 2007 STK2 EE EE 2019 STK2 EE 2019 or KZ EE 1819 STK2 EE 1819 or KZ EE 1619 STK2 EE 1619 or KZ EE 1419 STK2 EE EE 1219 STK2 EE

100 PTFE / FEP -90 C / +200 C 99 Shielded jacketed twisted triples ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP EE xxxx STK 3 SPC Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT EE 3207 STK3 EE 3207 or KZ EE 3007 STK3 EE 3007 or KZ EE 2807 STK3 EE 2807 or KZ EE 2607 STK3 EE 2607 or KZ EE 2619 STK3 EE EE 2407 STK3 EE 2407 or KZ EE 2419 STK3 EE EE 2207 STK3 EE 2207 or KZ EE 2219 STK3 EE EE 2007 STK3 EE EE 2019 STK3 EE 2019 or KZ EE 1819 STK3 EE 1819 or KZ EE 1619 STK3 EE 1619 or KZ EE 1419 STK3 EE EE 1219 STK3 EE

101 C / +200 C Shielded jacketed twisted quads PTFE / FEP ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP EE xxxx STK 4 SPC Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT EE 3207 STK4 EE 3207 or KZ EE 3007 STK4 EE 3007 or KZ EE 2807 STK4 EE 2807 or KZ EE 2607 STK4 EE 2607 or KZ EE 2619 STK4 EE EE 2407 STK4 EE 2407 or KZ EE 2419 STK4 EE EE 2207 STK4 EE 2207 or KZ EE 2219 STK4 EE EE 2007 STK4 EE EE 2019 STK4 EE 2019 or KZ EE 1819 STK4 EE 1819 or KZ EE 1619 STK4 EE 1619 or KZ EE 1419 STK4 EE EE 1219 STK4 EE

102 PTFE / FEP -90 C / +200 C 101 Shielded jacketed single core cables ASTM-D-2116 ASTM -D-4895 NF-C NEMA-HP3 KZ 55, ET xxxx H STK 1 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NF-C NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE PROTECTION 3 - Protection: Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 5 - Jacket: extruded FEP Shielded & jacketed cables NF (see page 18) JACKET BRAI- DED SHIELD OUTER ET 2607 H STK1 KZ ET 2607 or KZ ET 2407 H STK1 KZ ET 2407 or KZ ET 2207 H STK1 KZ ET 2207 or KZ ET 2019 H STK1 KZ ET 2019 or KZ APPROX. WEIGHT

103 C / +200 C Shielded jacketed twisted pairs PTFE / FEP ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 67, ET xxxx H STK 2 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NF-C NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE PROTECTION 3 - Protection: Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 5 - Jacket: extruded FEP NF (see page 18) JACKET BRAI- DED SHIELD OUTER APPROX. WEIGHT ET 3207 H STK2 KZ ET 3207 or KZ ET 3007 H STK2 KZ ET 3007 or KZ ET 2807 H STK2 KZ ET 2807 or KZ ET 2607 H STK2 KZ ET 2607 or KZ ET 2407 H STK2 KZ ET 2407 or KZ ET 2207 H STK2 KZ ET 2207 or KZ ET 2019 H STK2 KZ ET 2019 or KZ

104 PTFE / FEP Shielded twisted triples -90 C / +200 C 103 ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 79, ET xxxx H STK 3 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC CABLE NF-C NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE PROTECTION 3 - Protection: Polyimide separating tape 4 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 5 - Jacket: extruded FEP Shielded & jacketed cables NF (see page 18) JACKET BRAI- DED SHIELD OUTER APPROX. WEIGHT ET 3207 H STK3 KZ ET 3207 or KZ ET 3007 H STK3 KZ ET 3007 or KZ ET 2807 H STK3 KZ ET 2807 or KZ ET 2607 H STK3 KZ ET 2607 or KZ ET 2407 H STK3 KZ ET 2407 or KZ ET 2207 H STK3 KZ ET 2207 or KZ ET 2019 H STK3 KZ ET 2019 or KZ

105 C / +200 C PTFE / FEP Shielded jacketed single core cables ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 Insulation: PTFE / FEP KZ 57, E xxxx STK 1 SPC Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NF-C NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ E 3207 or KZ KZ E 3007 or KZ KZ E 2807 or KZ KZ E 2607 or KZ KZ E 2407 or KZ KZ E 2207 or KZ KZ E 2019 or KZ KZ E 1819 or KZ KZ E 1619 or KZ KZ RE 1427 or KZ KZ RE 1245 or KZ

106 PTFE / FEP -90 C / +200 C 105 Shielded jacketed twisted pairs ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 69, E xxxx STK 2 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NF-C NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ E 3207 or KZ KZ E 3007 or KZ KZ E 2807 or KZ KZ E 2607 or KZ KZ E 2407 or KZ KZ E 2207 or KZ KZ E 2019 or KZ KZ E 1819 or KZ KZ E 1619 or KZ KZ RE 1427 or KZ KZ RE 1245 or KZ

107 C / +200 C Shielded jacketed twisted triples PTFE / FEP ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 81, E xxxx STK 3 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC CABLE NF-C NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 19) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ E 3207 or KZ KZ E 3007 or KZ KZ E 2807 or KZ KZ E 2607 or KZ KZ E 2407 or KZ KZ E 2207 or KZ KZ E 2019 or KZ KZ E 1819 or KZ KZ E 1619 or KZ KZ RE 1427 or KZ KZ RE 1245 or KZ

108 PTFE / FEP -90 C / +200 C 107 Shielded jacketed single core cables ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 59, EE xxxx STK 1 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NF-C NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ EE 3207 or KZ KZ EE 3007 or KZ KZ EE 2807 or KZ KZ EE 2607 or KZ KZ EE 2407 or KZ KZ EE 2207 or KZ KZ EE 2019 or KZ KZ EE 1819 or KZ KZ EE 1619 or KZ KZ REE 1427 or KZ KZ REE 1245 or KZ

109 C / +200 C Shielded jacketed twisted pairs PTFE / FEP ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 71, EE xxxx STK 2 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NF-C NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ EE 3207 or KZ KZ EE 3007 or KZ KZ EE 2807 or KZ KZ EE 2607 or KZ KZ EE 2407 or KZ KZ EE 2207 or KZ KZ EE 2019 or KZ KZ EE 1819 or KZ KZ EE 1619 or KZ KZ REE 1427 or KZ KZ REE 1245 or KZ

110 PTFE / FEP -90 C / +200 C 109 Shielded jacketed twisted triples ASTM-D-2116 ASTM-D-4895 NF-C NEMA-HP3 KZ 83, EE xxxx STK 3 SPC Insulation: PTFE / FEP Operating temperature: -90 C / +200 C Voltage rating: 1000 Volts AC CABLE NF-C NEMA-WC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded PTFE 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 20) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KZ EE 3207 or KZ KZ EE 3007 or KZ KZ EE 2807 or KZ KZ EE 2607 or KZ KZ EE 2407 or KZ KZ EE 2207 or KZ KZ EE 2019 or KZ KZ EE 1819 or KZ KZ EE 1619 or KZ KZ REE 1427 or KZ KZ REE 1245 or KZ

111 C / +200 C FEP / FEP Shielded jacketed single core cables ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 KT xxxx STK 1 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 250 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 29) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 3601 STK1 KT 3601 SCA KT 3607 STK1 KT 3607 SCA KT 3401 STK1 KT 3401 SCA KT 3407 STK1 KT 3407 SCA KT 3201 STK1 KT KT 3207 STK1 KT KT 3001 STK1 KT KT 3007 STK1 KT KT 3019 STK1 KT 3019 SCA KT 2801 STK1 KT KT 2807 STK1 KT KT 2819 STK1 KT KT 2601 STK1 KT KT 2607 STK1 KT KT 2619 STK1 KT KT 2401 STK1 KT KT 2407 STK1 KT KT 2419 STK1 KT KT 2201 STK1 KT KT 2207 STK1 KT KT 2219 STK1 KT KT 2001 STK1 KT KT 2007 STK1 KT KT 2019 STK1 KT

112 FEP / FEP -90 C / +200 C 111 Shielded jacketed twisted pairs ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 KT xxxx STK 2 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 250 Volts AC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 29) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 3601 STK2 KT 3601 SCA KT 3607 STK2 KT 3607 SCA KT 3401 STK2 KT 3401 SCA KT 3407 STK2 KT 3407 SCA KT 3201 STK2 KT KT 3207 STK2 KT KT 3001 STK2 KT KT 3007 STK2 KT KT 3019 STK2 KT 3019 SCA KT 2801 STK2 KT KT 2807 STK2 KT KT 2819 STK2 KT KT 2601 STK2 KT KT 2607 STK2 KT KT 2619 STK2 KT KT 2401 STK2 KT KT 2407 STK2 KT KT 2419 STK2 KT KT 2201 STK2 KT KT 2207 STK2 KT KT 2219 STK2 KT KT 2001 STK2 KT KT 2007 STK2 KT KT 2019 STK2 KT

113 C / +200 C Shielded jacketed twisted triples FEP / FEP ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 KT xxxx STK 3 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 250 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 29) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 3601 STK3 KT 3601 SCA KT 3607 STK3 KT 3607 SCA KT 3401 STK3 KT 3401 SCA KT 3407 STK3 KT 3407 SCA KT 3201 STK3 KT KT 3207 STK3 KT KT 3001 STK3 KT KT 3007 STK3 KT KT 3019 STK3 KT 3019 SCA KT 2801 STK3 KT KT 2807 STK3 KT KT 2819 STK3 KT KT 2601 STK3 KT KT 2607 STK3 KT KT 2619 STK3 KT KT 2401 STK3 KT KT 2407 STK3 KT KT 2419 STK3 KT KT 2201 STK3 KT KT 2207 STK3 KT KT 2219 STK3 KT KT 2001 STK3 KT KT 2007 STK3 KT KT 2019 STK3 KT

114 FEP / FEP -90 C / +200 C 113 Shielded jacketed twisted quads ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 KT xxxx STK 4 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 250 Volts AC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 29) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 3601 STK4 KT 3601 SCA KT 3607 STK4 KT 3607 SCA KT 3401 STK4 KT 3401 SCA KT 3407 STK4 KT 3407 SCA KT 3201 STK4 KT KT 3207 STK4 KT KT 3001 STK4 KT KT 3007 STK4 KT KT 3019 STK4 KT 3019 SCA KT 2801 STK4 KT KT 2807 STK4 KT KT 2819 STK4 KT KT 2601 STK4 KT KT 2607 STK4 KT KT 2619 STK4 KT KT 2401 STK4 KT KT 2407 STK4 KT KT 2419 STK4 KT KT 2201 STK4 KT KT 2207 STK4 KT KT 2219 STK4 KT KT 2001 STK4 KT KT 2007 STK4 KT KT 2019 STK4 KT

115 C / +200 C FEP / FEP Shielded jacketed single core cables ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 Insulation: FEP / FEP K xxxx STK 1 SPC or SCA Operating temperature: -90C / +200 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 31) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 3407 STK1 K 3407 SCA K 3207 STK1 K K 3007 STK1 K K 2807 STK1 K K 2607 STK1 K K 2619 STK1 K K 2407 STK1 K K 2419 STK1 K K 2207 STK1 K K 2219 STK1 K K 2007 STK1 K K 2019 STK1 K K 1819 STK1 K K 1619 STK1 K K 1419 STK1 K K 1219 STK1 K K 1037 STK1 K

116 FEP / FEP -90 C / +200 C 115 Shielded jacketed twisted pairs ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 K xxxx STK 2 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 600 Volts AC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 31) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 3407 STK2 K 3407 SCA K 3207 STK2 K K 3007 STK2 K K 2807 STK2 K K 2607 STK2 K K 2619 STK2 K K 2407 STK2 K K 2419 STK2 K K 2207 STK2 K K 2219 STK2 K K 2007 STK2 K K 2019 STK2 K K 1819 STK2 K K 1619 STK2 K K 1419 STK2 K K 1219 STK2 K K 1037 STK2 K

117 C / +200 C Shielded jacketed twisted triples FEP / FEP ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 K xxxx STK 3 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 31) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 3407 STK3 K 3407 SCA K 3207 STK3 K K 3007 STK3 K K 2807 STK3 K K 2607 STK3 K K 2619 STK3 K K 2407 STK3 K K 2419 STK3 K K 2207 STK3 K K 2219 STK3 K K 2007 STK3 K K 2019 STK3 K K 1819 STK3 K K 1619 STK3 K K 1419 STK3 K K 1219 STK3 K K 1037 STK3 K

118 FEP / FEP -90 C / +200 C 117 Shielded jacketed twisted quads ASTM-B-624 ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 K xxxx STK 4 SPC or SCA Insulation: FEP / FEP Operating temperature: -90C / +200 C Voltage rating: 600 Volts AC Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA) 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 31) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 3407 STK4 K 3407 SCA K 3207 STK4 K K 3007 STK4 K K 2807 STK4 K K 2607 STK4 K K 2619 STK4 K K 2407 STK4 K K 2419 STK4 K K 2207 STK4 K K 2219 STK4 K K 2007 STK4 K K 2019 STK4 K K 1819 STK4 K K 1619 STK4 K K 1419 STK4 K K 1219 STK4 K K 1037 STK4 K

119 C / +200 C FEP / FEP Shielded jacketed single core cables ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 Insulation: FEP / FEP KK xxxx STK 1 SPC Operating temperature: -90C / +200 C Voltage rating: 1000 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 33) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KK 3207 STK1 KK KK 3007 STK1 KK KK 2807 STK1 KK KK 2607 STK1 KK KK 2619 STK1 KK KK 2407 STK1 KK KK 2419 STK1 KK KK 2207 STK1 KK KK 2219 STK1 KK KK 2007 STK1 KK KK 2019 STK1 KK KK 1819 STK1 KK KK 1619 STK1 KK KK 1419 STK1 KK KK 1219 STK1 KK KK 1037 STK1 KK

120 FEP / FEP -90 C / +200 C 119 Shielded jacketed twisted pairs ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 Insulation: FEP / FEP KK xxxx STK 2 SPC Operating temperature: -90C / +200 C Voltage rating: 1000 Volts AC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 33) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KK 3207 STK2 KK KK 3007 STK2 KK KK 2807 STK2 KK KK 2607 STK2 KK KK 2619 STK2 KK KK 2407 STK2 KK KK 2419 STK2 KK KK 2207 STK2 KK KK 2219 STK2 KK KK 2007 STK2 KK KK 2019 STK2 KK KK 1819 STK2 KK KK 1619 STK2 KK KK 1419 STK2 KK KK 1219 STK2 KK KK 1037 STK2 KK

121 C / +200 C Shielded jacketed twisted triples FEP / FEP ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 Insulation: FEP / FEP KK xxxx STK 3 SPC Operating temperature: -90C / +200 C Voltage rating: 1000 Volts AC Shielded & jacketed cables 1 - Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 33) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KK 3207 STK3 KK KK 3007 STK3 KK KK 2807 STK3 KK KK 2607 STK3 KK KK 2619 STK3 KK KK 2407 STK3 KK KK 2419 STK3 KK KK 2207 STK3 KK KK 2219 STK3 KK KK 2007 STK3 KK KK 2019 STK3 KK KK 1819 STK3 KK KK 1619 STK3 KK KK 1419 STK3 KK KK 1219 STK3 KK KK 1037 STK3 KK

122 FEP / FEP -90 C / +200 C 121 Shielded jacketed twisted quads ASTM-D-2116 NEMA-HP4 CABLE NEMA-WC27500 Insulation: FEP / FEP KK xxxx STK 4 SPC Operating temperature: -90C / +200 C Voltage rating: 1000 Volts AC Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 33) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KK 3207 STK4 KK KK 3007 STK4 KK KK 2807 STK4 KK KK 2607 STK4 KK KK 2619 STK4 KK KK 2407 STK4 KK KK 2419 STK4 KK KK 2207 STK4 KK KK 2219 STK4 KK KK 2007 STK4 KK KK 2019 STK4 KK KK 1819 STK4 KK KK 1619 STK4 KK KK 1419 STK4 KK KK 1219 STK4 KK KK 1037 STK4 KK

123 122-55C / +150C FEP / FEP Shielded jacketed single core cables ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP KT xxxx TSTK1 TPC Operating temperature: -55C / +150C Voltage rating: 250 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 30) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 2807 TSTK 1 KT 2807 TPC KT 2619 TSTK 1 KT 2619 TPC KT 2419 TSTK 1 KT 2419 TPC KT 2237 TSTK 1 KT 2237 TPC KT 2037 TSTK 1 KT 2037 TPC

124 FEP / FEP -55C / +150C 123 Shielded jacketed twisted pairs ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP KT xxxx THSTK 2 TPC Operating temperature: -55C / +150C Voltage rating: 250 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded FEP PROTECTION 3 - Polyimide separating tape 4 - Braided shield: tin plated annealed copper OUTER JACKET 5 - Jacket: extruded FEP Shielded & jacketed cables (see page 30) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 2807 THSTK 2 KT 2807 TPC KT 2619 THSTK 2 KT 2619 TPC KT 2419 THSTK 2 KT 2419 TPC KT 2237 THSTK 2 KT 2237 TPC KT 2037 THSTK 2 KT 2037 TPC

125 124-55C / +150C Shielded jacketed twisted triples FEP / FEP ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP KT xxxx THSTK 3 TPC Operating temperature: -55C / +150C Voltage rating: 250 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded FEP PROTECTION 3 - Polyimide separating tape 4 - Braided shield: tin plated annealed copper OUTER JACKET 5 - Jacket: extruded FEP (see page 30) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KT 2807 THSTK 3 KT 2807 TPC KT 2619 THSTK 3 KT 2619 TPC KT 2419 THSTK 3 KT 2419 TPC KT 2237 THSTK 3 KT 2237 TPC KT 2037 THSTK 3 KT 2037 TPC

126 FEP / FEP -55C / +150C 125 Shielded jacketed single core cables ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP K xxxx TSTK 1 TPC Operating temperature: -55C / +150C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 32) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 2807 TSTK 1 K 2807 TPC K 2619 TSTK 1 K 2619 TPC K 2419 TSTK 1 K 2419 TPC K 2237 TSTK 1 K 2237 TPC K 2037 TSTK 1 K 2037 TPC K 1861 TSTK 1 K 1861 TPC K 1661 TSTK 1 K 1661 TPC K 1461 TSTK 1 K 1461 TPC K 1291 TSTK 1 K 1291 TPC K 1091 TSTK 1 K 1091 TPC K 8133 TSTK 1 K 8133 TPC

127 126-55C / +150C Shielded jacketed twisted pairs FEP / FEP ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP K xxxx TSTK 2 TPC Operating temperature: -55C / +150C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 32) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 2807 TSTK 2 K 2807 TPC K 2619 TSTK 2 K 2619 TPC K 2419 TSTK 2 K 2419 TPC K 2237 TSTK 2 K 2237 TPC K 2037 TSTK 2 K 2037 TPC K 1861 TSTK 2 K 1861 TPC K 1661 TSTK 2 K 1661 TPC K 1461 TSTK 2 K 1461 TPC K 1291 TSTK 2 K 1291 TPC K 1091 TSTK 2 K 1091 TPC K 8133 TSTK 2 K 8133 TPC

128 FEP / FEP -55C / +150C 127 Shielded jacketed twisted triples ASTM-B-33 ASTM-D-2116 Insulation: FEP / FEP K xxxx TSTK 3 TPC Operating temperature: -55C / +150C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded FEP 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 32) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT K 2807 TSTK 3 K 2807 TPC K 2619 TSTK 3 K 2619 TPC K 2419 TSTK 3 K 2419 TPC K 2237 TSTK 3 K 2237 TPC K 2037 TSTK 3 K 2037 TPC K 1861 TSTK 3 K 1861 TPC K 1661 TSTK 3 K 1661 TPC K 1461 TSTK 3 K 1461 TPC K 1291 TSTK 3 K 1291 TPC K 1091 TSTK 3 K 1091 TPC K 8133 TSTK 3 K 8133 TPC

129 C / +155 C ETFE / FEP Shielded jacketed single core cables LIGHT WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZL xxxx STK 1 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STK1 ZL 3007 or KU ZL 2807 STK1 ZL 2807 or KU ZL 2619 STK1 ZL 2619 or KU ZL 2419 STK1 ZL 2419 or KU ZL 2219 STK1 ZL 2219 or KU ZL 2019 STK1 ZL ZL 1819 STK1 ZL ZL 1619 STK1 ZL ZL 1419 STK1 ZL ZL 1237 STK1 ZL ZL 1037 STK1 ZL

130 ETFE / FEP -90 C / +155 C 129 Shielded jacketed twisted pairs LIGHT WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZL xxxx STK 2 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STK2 ZL 3007 or KU ZL 2807 STK2 ZL 2807 or KU ZL 2619 STK2 ZL 2619 or KU ZL 2419 STK2 ZL 2419 or KU ZL 2219 STK2 ZL 2219 or KU ZL 2019 STK2 ZL ZL 1819 STK2 ZL ZL 1619 STK2 ZL ZL 1419 STK2 ZL ZL 1237 STK2 ZL ZL 1037 STK2 ZL

131 C / +155 C Shielded jacketed twisted triples ETFE / FEP LIGHT WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZL xxxx STK 3 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STK3 ZL 3007 or KU ZL 2807 STK3 ZL 2807 or KU ZL 2619 STK3 ZL 2619 or KU ZL 2419 STK3 ZL 2419 or KU ZL 2219 STK3 ZL 2219 or KU ZL 2019 STK3 ZL ZL 1819 STK3 ZL ZL 1619 STK3 ZL ZL 1419 STK3 ZL ZL 1237 STK3 ZL ZL 1037 STK3 ZL

132 ETFE / FEP -90 C / +155 C 131 Shielded jacketed twisted quads LIGHT WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZL xxxx STK 4 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STK4 ZL 3007 or KU ZL 2807 STK4 ZL 2807 or KU ZL 2619 STK4 ZL 2619 or KU ZL 2419 STK4 ZL 2419 or KU ZL 2219 STK4 ZL 2219 or KU ZL 2019 STK4 ZL ZL 1819 STK4 ZL ZL 1619 STK4 ZL ZL 1419 STK4 ZL ZL 1237 STK4 ZL ZL 1037 STK4 ZL

133 C / +155 C ETFE / FEP Shielded jacketed single core cables MEDIUM WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZN xxxx STK 1 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STK1 ZN ZN 2807 STK1 ZN ZN 2619 STK1 ZN ZN 2419 STK1 ZN ZN 2219 STK1 ZN ZN 2019 STK1 ZN 2019 or KU ZN 1819 STK1 ZN 1819 or KU ZN 1619 STK1 ZN 1619 or KU ZN 1419 STK1 ZN ZN 1237 STK1 ZN 1237 or KU ZN 1037 STK1 ZN

134 ETFE / FEP -90 C / +155 C 133 Shielded jacketed twisted pairs MEDIUM WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZN xxxx STK 2 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STK2 ZN ZN 2807 STK2 ZN ZN 2619 STK2 ZN ZN 2419 STK2 ZN ZN 2219 STK2 ZN ZN 2019 STK2 ZN 2019 or KU ZN 1819 STK2 ZN 1819 or KU ZN 1619 STK2 ZN 1619 or KU ZN 1419 STK2 ZN ZN 1237 STK2 ZN 1237 or KU ZN 1037 STK2 ZN

135 C / +155 C Shielded jacketed twisted triples ETFE / FEP MEDIUM WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZN xxxx STK 3 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC27500 Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STK3 ZN ZN 2807 STK3 ZN ZN 2619 STK3 ZN ZN 2419 STK3 ZN ZN 2219 STK3 ZN ZN 2019 STK3 ZN 2019 or KU ZN 1819 STK3 ZN 1819 or KU ZN 1619 STK3 ZN 1619 or KU ZN 1419 STK3 ZN ZN 1237 STK3 ZN 1237 or KU ZN 1037 STK3 ZN

136 ETFE / FEP -90 C / +155 C 135 Shielded jacketed twisted quads MEDIUM WEIGHT ASTM-B-33 ASTM-D-2116 ASTM-D-3159 NF-C SAE-AS22759 Insulation: ETFE / FEP ZN xxxx STK 4 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC CABLE NEMA-WC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded FEP Shielded & jacketed cables (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STK4 ZN ZN 2807 STK4 ZN ZN 2619 STK4 ZN ZN 2419 STK4 ZN ZN 2219 STK4 ZN ZN 2019 STK4 ZN 2019 or KU ZN 1819 STK4 ZN 1819 or KU ZN 1619 STK4 ZN 1619 or KU ZN 1419 STK4 ZN ZN 1237 STK4 ZN 1237 or KU ZN 1037 STK4 ZN

137 C / +155 C ETFE / ETFE Shielded jacketed single core cables LIGHT WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZL xxxx STZ 1 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STZ1 ZL 3007 or KU ZL 2807 STZ1 ZL 2807 or KU ZL 2619 STZ1 ZL 2619 or KU ZL 2419 STZ1 ZL 2419 or KU ZL 2219 STZ1 ZL 2219 or KU ZL 2019 STZ1 ZL ZL 1819 STZ1 ZL ZL 1619 STZ1 ZL

138 ETFE / ETFE -90 C / +155 C 137 Shielded jacketed twisted pairs LIGHT WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZL xxxx STZ 2 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE Shielded & jacketed cables (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STZ2 ZL 3007 or KU ZL 2807 STZ2 ZL 2807 or KU ZL 2619 STZ2 ZL 2619 or KU ZL 2419 STZ2 ZL 2419 or KU ZL 2219 STZ2 ZL 2219 or KU ZL 2019 STZ2 ZL ZL 1819 STZ2 ZL ZL 1619 STZ2 ZL

139 C / +155 C Shielded jacketed twisted triples ETFE / ETFE LIGHT WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZL xxxx STZ 3 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STZ3 ZL 3007 or KU ZL 2807 STZ3 ZL 2807 or KU ZL 2619 STZ3 ZL 2619 or KU ZL 2419 STZ3 ZL 2419 or KU ZL 2219 STZ3 ZL 2219 or KU ZL 2019 STZ3 ZL ZL 1819 STZ3 ZL ZL 1619 STZ3 ZL

140 ETFE / ETFE -90 C / +155 C 139 Shielded jacketed twisted quads LIGHT WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZL xxxx STZ 4 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE Shielded & jacketed cables (see page 34) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZL 3007 STZ4 ZL 3007 or KU ZL 2807 STZ4 ZL 2807 or KU ZL 2619 STZ4 ZL 2619 or KU ZL 2419 STZ4 ZL 2419 or KU ZL 2219 STZ4 ZL 2219 or KU ZL 2019 STZ4 ZL ZL 1819 STZ4 ZL ZL 1619 STZ4 ZL

141 C / +155 C ETFE / ETFE Shielded jacketed single core cables MEDIUM WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZN xxxx STZ 1 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STZ1 ZN ZN 2807 STZ1 ZN ZN 2619 STZ1 ZN ZN 2419 STZ1 ZN ZN 2219 STZ1 ZN ZN 2019 STZ1 ZN 2019 or KU ZN 1819 STZ1 ZN 1819 or KU ZN 1619 STZ1 ZN 1619 or KU ZN 1419 STZ1 ZN ZN 1237 STZ1 ZN 1237 or KU ZN 1037 STZ1 ZN

142 ETFE / ETFE -90 C / +155 C 141 Shielded jacketed twisted pairs MEDIUM WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZN xxxx STZ 2 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE Shielded & jacketed cables (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STZ2 ZN ZN 2807 STZ2 ZN ZN 2619 STZ2 ZN ZN 2419 STZ2 ZN ZN 2219 STZ2 ZN ZN 2019 STZ2 ZN 2019 or KU ZN 1819 STZ2 ZN 1819 or KU ZN 1619 STZ2 ZN 1619 or KU ZN 1419 STZ2 ZN ZN 1237 STZ2 ZN 1237 or KU ZN 1037 STZ2 ZN

143 C / +155 C Shielded jacketed twisted triples ETFE / ETFE MEDIUM WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZN xxxx STZ 3 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STZ3 ZN ZN 2807 STZ3 ZN ZN 2619 STZ3 ZN ZN 2419 STZ3 ZN ZN 2219 STZ3 ZN ZN 2019 STZ3 ZN 2019 or KU ZN 1819 STZ3 ZN 1819 or KU ZN 1619 STZ3 ZN 1619 or KU ZN 1419 STZ3 ZN ZN 1237 STZ3 ZN 1237 or KU ZN 1037 STZ3 ZN

144 ETFE / ETFE -90 C / +155 C 143 Shielded jacketed twisted quads MEDIUM WEIGHT ASTM-B-33 ASTM-D-3159 NF-C SAE-AS22759 CABLE NEMA-WC27500 Insulation: ETFE / ETFE ZN xxxx STZ 4 TPC Operating temperature: -90 C / +155 C Voltage rating: 600 Volts AC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE Shielded & jacketed cables (see page 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT ZN 3007 STZ4 ZN ZN 2807 STZ4 ZN ZN 2619 STZ4 ZN ZN 2419 STZ4 ZN ZN 2219 STZ4 ZN ZN 2019 STZ4 ZN 2019 or KU ZN 1819 STZ4 ZN 1819 or KU ZN 1619 STZ4 ZN 1619 or KU ZN 1419 STZ4 ZN ZN 1237 STZ4 ZN 1237 or KU ZN 1037 STZ4 ZN

145 C / +150 C ETFE / ETFE Shielded jacketed single core cables ASTM-B-33 ASTM-D-3159 CABLE NF-C Insulation: ETFE / ETFE Operating temperature: -55 C / +150 C Voltage rating: 600 Volts AC KU 02 - xx TPC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see pages 34, 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU

146 ETFE / ETFE -55 C / +150 C 145 Shielded jacketed twisted pairs ASTM-B-33 ASTM-D-3159 CABLE NF-C Insulation: ETFE / ETFE Operating temperature: -55 C / +150 C Voltage rating: 600 Volts AC KU 05 - xx TPC Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE Shielded & jacketed cables (see pages 34, 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU

147 C / +150 C Shielded jacketed twisted triples ETFE / ETFE ASTM-B-33 ASTM-D-3159 CABLE NF-C Insulation: ETFE / ETFE Operating temperature: -55 C / +150 C Voltage rating: 600 Volts AC KU 06 - xx TPC Shielded & jacketed cables 1 - Conductor: tin plated annealed copper 2 - Insulation: extruded ETFE 3 - Braided shield: tin plated annealed copper OUTER JACKET 4 - Jacket: extruded ETFE (see pages 34, 35) JACKET BRAIDED SHIELD OUTER APPROX. WEIGHT KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU KU

148 147 Extra flexible wires & cables The extra fl exible wires & cables are useful for any dynamic applications where a high fl ex-life is needed. Made from a wrapped PTFE insulation, they resist -90 C to +200 C.

149

150 WRAPPED PTFE TAPE Extra fl exible single wires -90 C / +200 C 149 ASTM-D-4895 RET xxxx SPC Insulation: WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT RET x RET x RET x RET x RET x RET x RET x Extra flexible wires & cables

151 C / +200 C Extra fl exible single wires WRAPPED PTFE TAPE ASTM-D-4895 RE xxxx SPC Insulation: WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Standard multicores: see page Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape Extra flexible wires & cables AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT RE x RE x RE x RE x RE x RE x

152 WRAPPED PTFE TAPE -90 C / +200 C 151 Extra fl exible shielded jacketed single core cables RET xxxx Sh E1 SPC ASTM-D-4895 Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape (see page 149) JACKET OUTER APPROX. WEIGHT RET 2633 Sh E1 RET RET 2456 Sh E1 RET RET 2272 Sh E1 RET RET Sh E1 RET Extra flexible wires & cables

153 C / +200 C WRAPPED PTFE TAPE Extra fl exible shielded jacketed twisted pairs ASTM-D-4895 RET xxxx Sh E2 SPC Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape Extra flexible wires & cables (see page 149) JACKET OUTER APPROX. WEIGHT RET 3019 Sh E2 RET RET 2819 Sh E2 RET RET 2633 Sh E2 RET RET 2456 Sh E2 RET RET 2272 Sh E2 RET RET Sh E2 RET

154 WRAPPED PTFE TAPE -90 C / +200 C 153 Extra fl exible shielded jacketed twisted triples ASTM-D-4895 RET xxxx Sh E3 SPC Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape (see page 149) JACKET OUTER APPROX. WEIGHT RET 2819 Sh E3 RET Extra flexible wires & cables

155 C / +200 C WRAPPED PTFE TAPE Extra fl exible shielded jacketed single core cables RE xxxx Sh E1 SPC ASTM-D-4895 Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape Extra flexible wires & cables (see page 150) JACKET OUTER APPROX. WEIGHT RE Sh E1 RE RE Sh E1 RE

156 WRAPPED PTFE TAPE -90 C / +200 C 155 Extra fl exible shielded jacketed twisted pairs ASTM-D-4895 RE xxxx Sh E2 SPC Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape (see page 150) JACKET OUTER APPROX. WEIGHT RE 2272 Sh E2 RE RE Sh E2 RE RE Sh E2 RE Extra flexible wires & cables

157 C / +200 C WRAPPED PTFE TAPE Extra fl exible shielded jacketed twisted triples ASTM-D-4895 RE xxxx Sh E3 SPC Insulation: WRAPPED PTFE / WRAPPED PTFE Operating temperature: -90 C / +200 C Voltage rating: 600 Volts AC Standard colours: see page 6. Other colours Conductor: extra fl exible stranded electrolytic silver plated annealed copper 2 - Insulation: wrapped and sintered PTFE tape 3 - Served wire shield: electrolytic silver plated annealed copper OUTER JACKET 4 - Jacket: wrapped and sintered PTFE tape Extra flexible wires & cables (see page 150) JACKET OUTER APPROX. WEIGHT RE 2633 Sh E3 RE RE 2456 Sh E3 RE RE 2272 Sh E3 RE RE Sh E3 RE RE Sh E3 RE RE Sh E3 RE

158 157 Wire-wrap single wires Wire-wrap wires & cables are useful for wrapped connections. They can be insulated with: - PTFE or FEP to withstand -90 C to +200 C. - ETFE to withstand -90 C to +155 C. - Wrapped Polyimide to withstand -90 C to +200 C.

159

160 PTFE -90 C / +200 C Wire-wrap single wires 159 ASTM-B-624 ASTM-D-4895 NF-C NEMA-HP3 AET, WET, WE xxxx SPC or SCA Insulation: PTFE Operating temperature: -90 C / +200 C Voltage rating: 250 / 350 / 600 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA). 2 - Insulation: extruded PTFE NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT AET 3001 SCA 30 1x AET x WET 3001 KW A2 HP3-ETXBBA 30 1x WET 2801 KW A2 28 1x WET 2601 KW A2 HP3-ETXBDA 26 1x WET 2401 HP3-ETXBEA 24 1x WE 3001 HP3-EXBBA 30 1x WE x WE 2601 HP3-EXBDA 26 1x WE 2401 KW A2 HP3-EXBEA 24 1x WE 2201 HP3-EXBFA 22 1x WE 2001 HP3-EXBGA 20 1x VOLTAGE RATING (V AC) According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not. Wire-wrap single wires

161 C / +200 C FEP Wire-wrap single wires ASTM-D-2116 NF-C NEMA-HP3 AKT, WKT, WK xxxx SPC Insulation: FEP Operating temperature: -90 C / +200 C Voltage rating: 250 / 350 / 600 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper 2 - Insulation: extruded FEP Wire-wrap single wires NF NEMA AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT AKT x AKT x WKT 3001 KW A2 HP4-KTBBA 30 1x WKT 2801 KW A2 28 1x WKT 2601 KW A2 HP4-KTBDA 26 1x WKT 2401 HP4-KTBEA 24 1x WK 3001 HP4-KBBA 30 1x WK x WK 2601 HP4-KBDA 26 1x WK 2401 KW A2 HP4-KBEA 24 1x WK 2201 HP4-KBAA 22 1x WK 2001 HP4-KBGA 20 1x VOLTAGE RATING (V AC) According to the NEMA standard, extruded or taped PTFE and FEP single wires with a voltage of 600 or 1000 Volts and a wire gauge greater than or equal to 22 have to be marked, whereas the corresponding standard Axon wires are not.

162 ETFE -90 C / +155 C Wire-wrap single wires 161 ASTM-B-624 ASTM-D-3159 NF-C AZT, WZT, WZ xxxx SPC or SCA Insulation: ETFE Operating temperature: -90 C / +155 C Voltage rating: 250 / 350 / 600 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA). 2 - Insulation: extruded ETFE NF AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT AZT x AZT x WZT 3001TF KW B1 30 1x WZT 3001 KW B1 30 1x WZT 2801 KW B1 28 1x WZT 2601 KW B1 26 1x WZT x WZT x WZT x WZ x WZ x WZ x WZ 2401 KW B1 24 1x WZ x WZ x VOLTAGE RATING (V AC) Wire-wrap single wires

163 C / +200 C WRAPPED POLYIMIDE Wire-wrap single wires ASTM-B-624 AHT, WHT, WH xxxx SPC or SCA Insulation: WRAPPED POLYIMIDE Operating temperature: -90 C / +200 C Voltage rating: 250 / 600 Volts AC Standard colours: see page 6. Other colours Conductor: electrolytic silver plated annealed copper or high strength silver plated copper alloy (SCA). 2 - Insulation: wrapped and sealed Polyimide tape Wire-wrap single wires AWG CONSTRUCTION (NB X Ø mm) AREA (mm 2 ) RESISTANCE (Ω/100m) Ø (mm) APPROX. WEIGHT AHT 3001 SCA 30 1x WHT 3001 SCA 30 1x WHT 2801 SCA 28 1x WHT x WH x WH x WH x VOLTAGE RATING (V AC)

164 163 APPENDICES Appendices

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

Hook-Up Wire Alpha Wire ALPHA 373

Hook-Up Wire Alpha Wire ALPHA 373 Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 373 The broad range of hookup wire from Alpha means you will find the product exactly suited to

More information

Mil-Spec Wire and Cable

Mil-Spec Wire and Cable MilSpec Wire and Cable NEMA HP3/4 Reference Guide... page 2 NEMA HP3 Type E, EE, ET formerly M878/4, /5, /6... page 3 NEMA HP4 Type K, KK, KT formerly M878/11, /12, /... page 4 SAEAS 22759 Reference Guide...

More information

Cables for Space Applications

Cables for Space Applications Cables for Space Applications Summary Company profile... Page 2 Cross Reference Table... Page 3 ESA ISO9001/EN9100 Certificates... Page 4 SCC 3901 001 Series... Page 7 SCC 3901 002 Series... Page 11 SCC

More information

Hook-Up Wire Cables you trust. Service you deserve.

Hook-Up Wire Cables you trust. Service you deserve. Hook-Up Wire Everything You Need to Hook Up Anything The broad range of hook-up wire from Alpha Wire means you will find the wire exactly suited to your application whether it s as straightforward as a

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12

More information

MaxFlite high-performance 100 Base-T Ethernet cables

MaxFlite high-performance 100 Base-T Ethernet cables MaxFlite high-performance 100 Base-T Ethernet cables MaxFlite data cables are high-performance, highspeed 100 Base-T Ethernet cables designed for use in aircraft IFE (In-Flight Entertainment) systems.

More information

Standard hook-up wires and cables for Electronics Filotex

Standard hook-up wires and cables for Electronics Filotex Standard hook-up wires and cables for Electronics Filotex . Content Guideline of wires and cables... 4 Part 1 - Standard coaxial cables... 7 KX & RG standard coaxial cables... 9 Data bus cable M17/176-00002...

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

CABLED TWISTED PAIRS CONDUCTORS

CABLED TWISTED PAIRS CONDUCTORS CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies Litz Wire Litz Wire Manufacturers of electronic components need a dependable source for Litz wire of the highest quality. pioneered and continues to be a leader in the manufacturing of high quality Litz

More information

AXON. Innovative Interconnect Solutions

AXON. Innovative Interconnect Solutions AXON Innovative Interconnect Solutions SUMMARY THE AXON GROUP OUR TECHNOLOGICAL EXPERTISE IN MATERIALS OUR PRODUCT EXPERTISE QUALITY OUR PROCESS EXPERTISE «GREY MATTER» PROJECT TEAMS THE RESULT OF INNOVATION

More information

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable ed Primary UD TRXLP ed Primary UD TRXLP Cable Aluminum or Copper Conductor. TRXLP Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

Catalogue. Index INDUSTRIAL CABLE

Catalogue. Index INDUSTRIAL CABLE Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL

More information

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is

More information

Conductors Braids Special products made of copper wire

Conductors Braids Special products made of copper wire Conductors Braids Special products made of copper wire Content 3 Introduction 4 Earthing straps MB 5 Current leads SB 6 Connectors VB 7 Copper welding parts Copper cutting parts KST 8 Flat copper conductors

More information

CABLED SINGLE CONDUCTORS

CABLED SINGLE CONDUCTORS CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSM. Terminal Blocks

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSM. Terminal Blocks RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 MSM Terminal Blocks Functional characteristics Dimensional class: medium RoHS 2011/65/EU Standard colour: green Height: 15.2

More information

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES ABOUT LABFACILITY Formed in 1971, Labfacility specialises in the field of Temperature and Process Measurement. We are the largest UK manufacturer of both

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

X X. Marine Cables Zero Halogen X X X X X X. UK Defence Standard (part 25) X X. Limited Fire Hazard

X X. Marine Cables Zero Halogen X X X X X X. UK Defence Standard (part 25) X X. Limited Fire Hazard Limited Fire Hazard Marine Cables Zero Halogen UK Defence Standard 61-12 (part 25) Introduction Spliers to the Naval & Defence Market Zerohal Marine Cables The s in this guide are manufactured and approved

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................

More information

For the plastics machinery industry Manifold thermocouple Model TC47-MT

For the plastics machinery industry Manifold thermocouple Model TC47-MT Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould

More information

Omni Cable is a master distributor of specialty wire and cable selling

Omni Cable is a master distributor of specialty wire and cable selling Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer

More information

MMC RTX series EN3716

MMC RTX series EN3716 MMC RTX series EN3716 7 CONTENTS Page Introduction... 7-4 Application 7-4 Features... 7-4 Product overview... 7-5 Electrical characteristics... 7-6 Mechanical & environmental characteristics... 7-6 Products

More information

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table) Outer jacket: Pressure extruded PVC mixture Inner jacket: Pressure extruded, gusset filling PVC mixture Conductor: Fine-wire strand consisting of bare copper wires 6 1 Core insulation: Mechanically highquality

More information

DATA-CON-X : SEALED USB TYPE A & B CONNECTORS

DATA-CON-X : SEALED USB TYPE A & B CONNECTORS FEATURES & BENEFITS Sealed to IP67 & IP68 NEMA 250 (6P) (when mated) Feed-thru termination on the panel for easy field installation Field installable design is easy to assemble Quick connect bayonet or

More information

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company

More information

Industrial Ethernet Cables

Industrial Ethernet Cables Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

WATTSYS Power distribution system

WATTSYS Power distribution system www.axon-cable.com WATTSYS Power distribution system WATTSYS Power distribution systems As vital components for electrical power distribution in telecommunication satellites and landbased weapon systems,

More information

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044 for medium to high load requirements. Overview Class.PVC.PUR (3D-e-chain - cable) CAT5 (4x0,25)C (4x(2x0,25))C.PVC.040.PUR.040.040 CF14.02.02.02.CAT5 34 mm.041 CF14.02.04.02.CAT5 (5x(2x0,25))C 34 mm igus

More information

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N Electronic Cable CO N N E C T I N G T E C H N O LO G Y W I T H P E R F O R MA N C E & P R E C I S I O N Our Commitment Our Commitment to our customers is simple - we deliver even when others can t. As

More information

General characteristics and technical data Series MCS

General characteristics and technical data Series MCS MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

SECTION 7: MINIATURE SENSORS

SECTION 7: MINIATURE SENSORS SECTION 7: MINIATURE SENSORS Embedment sensors install in bearings for over-temperature protection Small, rugged RTDs and thermocouples withstand rough handling and harsh environments Certified non-sparking

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Data sheet chainflex CF140.UL

Data sheet chainflex CF140.UL 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

Data sheet chainflex CF10

Data sheet chainflex CF10 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture

More information

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant. Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

Flame Resistance, LOI 95 >

Flame Resistance, LOI 95 > Fluoropolymers 100 When Your Application Requires 100% Reliability. NWI fluoropolymer cables offer these outstanding performance characteristics: Resistance to flame, acids, solvents, chemicals and more

More information

series S01 (usually CLOSED)

series S01 (usually CLOSED) BIMETALLIC THERMAL PROTECTORS series S01 (usually CLOSED) voltage: 250 V AC 50/60 Hz n interventions: 2,5 A. (10000 cicli ) 6,3 A. (3000 cicli ) Homologations: UL/CSA/VDE/BEAB/SEMKO opening C ± 5% Cable

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12 Presentation Presentation The monolithic indicator banks in the Harmony XVC range are designed for long distance indication of the operating states or sequences of a machine or installation, either visually

More information

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/ Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection line Cat.5e, 4-pole, D-coded to IEC 61076-2-101 straight

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight

More information

Microphone and Musical Instrument Cable Overview

Microphone and Musical Instrument Cable Overview B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical

More information

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES SUBMERSIBLE PUMP CABLES GENERAL INTRODUCTION Bahra Cables Company was established in 2008 to serve Saudi & GCC Markets. It is based in Bahra industrial city located 25km from Jeddah. Bahra Cables Factory

More information

RoHS 2002/95/EC GREEN ELECTRONICS CSF. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007

RoHS 2002/95/EC GREEN ELECTRONICS CSF. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007 RoHS 2002/95/EC e3 GREEN ELECTRONICS CSF Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET STD PRODUCTS CONNECTORS

More information

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR DIVISION 16 - ELECTRICAL SECTION 16xx0 16xx0-1. GENERAL MANUFACTURED WIRING SYSTEM ACCESS FLOOR The modular convenience power system ensures the electrification and delivery of power from the power panels

More information

MC, THHN/THWN-2 Copper

MC, THHN/THWN-2 Copper MC, THHN/THWN-2 Copper PVC/Nylon Insulated, 600 V Features Standards UL listed as MC. UL 1569 Cable rated f Sunlight Resistance f CT use. is rated Oil Resistance I. s meet VW-1 flame test. conducts are

More information

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/ Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification multi-port Cat.5 plug to be assembled in the field 100 MBit suitable according to IEEE

More information

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)... MTW/TEW UL STYLE 1015...2 MTW/TEW UL STYLES 1028/1283/1284...3 UL STYLES 1007/1569...4 UL STYLE 1061...5 SWITCHBOARD WIRE (SIS)...6 UL STYLES 3173/3195/3196...7 UL STYLE 3321...8 TFN/TFFN/THHN-2/THWN-2/MTW...9

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MCM. Terminal Blocks

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MCM. Terminal Blocks RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 MCM Terminal Blocks MCM Functional characteristics Dimensional class: high RoHS 2011/65/EU Standard colour: green 0 Height: 14.45

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Type MMV-WP Medium Voltage Wind Power Cable

Type MMV-WP Medium Voltage Wind Power Cable WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation

More information

Data sheet... W-Series WPE 4

Data sheet... W-Series WPE 4 The PE terminals are available in two designs: standard and compact (N), with rated cross-section from 1.5 mm² to 150 mm² (e.g. 2.5 mm² WPE 2.5 or 4 mm² WPE 4N). General ordering data Order No. 1010100000

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

RoHS 2011/65/EU GREEN ELECTRONICS MSG. Terminal Blocks ISO 9001 ISO BS OHSAS 18001:2007

RoHS 2011/65/EU GREEN ELECTRONICS MSG. Terminal Blocks ISO 9001 ISO BS OHSAS 18001:2007 RoHS 2011/65/EU e3 GREEN ELECTRONICS Terminal Blocks ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET Standard PRODUCTS TERMINAL BLOCKS Functional characteristics s 270

More information

DEPARTMENT OF DEFENSE STANDARD PRACTICE IDENTIFICATION CODING AND APPLICATION OF HOOKUP AND LEAD WIRE

DEPARTMENT OF DEFENSE STANDARD PRACTICE IDENTIFICATION CODING AND APPLICATION OF HOOKUP AND LEAD WIRE NOTICE OF CHANGE INCH-POUND MIL-STD-681D NOTICE 1 19 June 2000 DEPARTMENT OF DEFENSE STANDARD PRACTICE IDENTIFICATION CODING AND APPLICATION OF HOOKUP AND LEAD WIRE TO ALL HOLDERS OF MIL-STD-681D: 1. THE

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation Type P Drilmar 125-XE Signal & Instrumentation Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 600/1000 V Features Engineered for easiest installation. Extra flexible stranding meets IEEE,

More information

Fuseholders PAGE. Fuseholders.

Fuseholders PAGE. Fuseholders. PAGE International Shock-Safe (Panel Mount).......................................................................... 467-468 Flip-Top Shock-Safe (Panel Mount)..................................................................................

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

RoHS 2002/95/EC GREEN ELECTRONICS PSQ. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007

RoHS 2002/95/EC GREEN ELECTRONICS PSQ. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007 RoHS 2002/95/EC e3 GREEN ELECTRONICS Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET Standard PRODUCTS PLURIMA

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information