Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch

Size: px
Start display at page:

Download "Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch"

Transcription

1 LABORATORY LOCATION: (PERMANENT LABORATORY) MITUTOYO (M) SDN. BHD. MAH SING INTEGRATED INDUSTRIAL PARK BANDAR PINGGIRAN SUBANG 4, JALAN UTARID U5/14, SECTION U SHAH ALAM SELANGOR, MALAYSIA Page: 1 of 5 This laboratory accredited under Skim Akreditasi Makmal Malaysia (SAMM) meets the requirements of :2005 General requirements for competence of testing and calibration laboratories. This Malaysian Standards is identical with ISO/IEC 17025:2005 published by the International Organization for Standardization (ISO). * The expanded uncertainties are based on an estimated confidence probability of approximately 95% and have a coverage factor of k=2 unless stated otherwise. Instrument / External micrometer 25, 50 and 100 frame Caliper Capability 25 travel 0.6 m using ceramic gauge block MICP/0002 Rev2.2 (JIS B7502:1994) Up to to to inch to 12 inch 6.5 m 9.2 m 25 m using MICP/0001 Rev2.2 (JIS B7507:1993) inch using MICP/0010 Rev1.0 Height gauge 0.01 to m using MICP/0003 Rev2.2 (JIS B7517:1993) as a

2 Page: 2 of 5 Instrument / Capability Expressed as Dial gauge to m using I checker MICP/0004 Rev2.3 (JIS B7503:2011) Gauge block 0.5 to to to to to m 0.05 m 0.07 m 0.09 m 0.12 m MICP/0007 Rev1.0 to JIS B 7506:2004 Dial test indicator to m using I checker MICP/0005 Rev2.3 (JIS B7533:1990) Digimatic indicator to m using I checker MICP/0006 Rev1.0 Holtest & Borematic Setting Rod 4 to to to m 4.0 m 3.2 m using standard ring gauge to MICP/0008 revision 1.0 (Mitutoyo in house using precision height gauge to MICP/0011 Rev 1.0

3 Page: 3 of 5 Instrument / Contact Type Coordinate Measuring Machine Non-contact Type Coordinate Measuring Machine X Axis : 0 to 700 Y Axis : 0 to 700 Z Axis : 0 to 700 X Axis : 700 to 1000 Y Axis : 700 to 1000 Z Axis : 700 to 1000 X Axis : 1000 to 1200 Y Axis : 1000 to 2000 Z Axis : 1000 to 1000 X Axis : 0 to 800 Y Axis : 0 to 800 Z Axis : 0 to 200 Capability 1.2 m Method-1 MOCP/001 Rev2.0 to JIS B7440:1987 & JIS7440-2:1997 as a 1.5 m to Method 2 MOCP/011 Rev1.0 to ISO :2009, ISO :2010 & ISO :2000 as a 6.8 m to MOCP/011 Rev3.0 ISO :2009, ISO :2010 & ISO :2000 as a 6.1 m MOCP/002 Rev2.0 Manufacturer s (Mitutoyo) Specification (in house procedures 1/98) Profile Projector X Axis : 0 to 200 Y Axis : 0 to 200 Toolmaker Microscope Contour testing Machine X Axis : 0 to 200 Y Axis : 0 to 200 X Axis : 0 to to m MOCP/003Rev2.0 (JIS B7184:1999) as a 3 m MOCP/004 Rev2.0 (JIS B7153:1995) as a X axis : 0.4 m Z axis : 0.1 m MOCP/006 Rev2.0 Manufacturer s (Mitutoyo)

4 Page: 4 of 5 Specification (in house procedures 3/98) Instrument / Linear Height X Axis : - Z Axis : 0 to 1000 Surface Roughness Testing Roundness measuring Machine 300 µm to +300 µm X Axis : -400 µm to +400 µm 400 µm to +400 µm Capability X axis : - Z axis : 8.0 m Method-1 MOCP/001 Rev2.0 to JIS B7440:1987 & JIS7440-2:1997 as a Guide 0.2 m MOCP/005 Rev2.0 (JIS B0651:2001) as a X Axis : 0.1 µm Y Axis : 0.1 µm MOCP/007 Rev2.0 (JIS B7451:1997) as a

5 Page: 5 of 5 HARDNESS Instrument / Hardness tester Rockwell scale 30 to 35 HRB 90 to 95 HRB 30 to 35 HRC 45 to 50 HRC 60 to 65 HRC Rockwell superficial scale 52 to 57 HR 30N 65 to 70 HR 30N 77 to 82 HR 30N 35 to 40 HR 30T 73 to 78 HR 30R Vickers scale 200HV10 300HV10 500HV10 500HV1 700HV30 Capability 1.0 HRB 1.0 HRB 2.0 HR 30T 1.0 HR 30T 3 HV 3 HV 7 HV to MOCP/009 B7726:2010) to MOCP/009 B7726:2010) to MOCP/010 B7725:2010) Micro Vickers 200HV HV1 500HV HV HV0.2 8 HV 28 HV 12 HV 36 HV to MOCP/010 B7725:2010)

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C. Page: 1 of 9 LABORATORY LOCATION: (PERMANENT LABORATORY) PPCALIBRATION SERVICES SDN. BHD. NO. 15, MEDAN BUKIT EMAS PUSAT PERNIAGAAN BUKIT EMAS 14000 BUKIT MERTAJAM, PULAU PINANG MALAYSIA This laboratory

More information

CALIBRATION SYSTEM CERTIFICATE

CALIBRATION SYSTEM CERTIFICATE CALIBRATION SYSTEM CERTIFICATE With respect to products (measuring instruments and testing instruments), we hereby certify that we have established our calibration system traceable to the national (international)

More information

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY * Metrix Precision Pte Ltd Certificate No. : LA-2014-0581-C No. 23 Tagore Lane #02-03/04 Tagore 23 Warehouse Issue No. : 2 Singapore 787601 Date : 29 July 2016 FIELD OF TESTING : Calibration and Measurement

More information

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10 µm 0 to 300 mm 12.0 µm Using Caliper Checker; Gauge 0 to 1000 mm 12.0 µm Block Set L.C. :-20 µm 0 to 600 mm 16.0 µm 0 to 1000 mm 20.0 µm

More information

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354 Calibration Instruments Height Master Page 345 Check Master Page 349 Calibration Tools Page 354 344 Digital Height Master Functions ZERO/ABS DATA/HOLD Auto Power OFF after 20 min. non use Low voltage alarm

More information

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra Last Amended on 24.05.2015 Page 1 of 5 I. DIMENSION 1. EXTERNAL MICROMETER $ L.C. 1 µm Φ >100 mm to 300 mm 1.4 µm 3.0 µm Using Slip Gauge Blocks Gr '0' / Long Slip Gauges, by Comparison 2. DEPTH MICROMETER

More information

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on Last Amended on 10.03.2016 Page 1 of 5 I. DIMENSION 1. Vernier caliper $ 0 to 300 mm/0.01 mm ± 12.0 µm Using Caliper Checker 0 to 300 mm/0.02 mm ± 16.1 µm Using Caliper Checker 0 to 600 mm/0.01 mm ± 14.0

More information

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date Last Amended on - Page 1 of 9 I. DIMENSION 1. CALIPER $ Vernier L.C. 0.01mm 7.5 µm 9.0 µm Using Caliper Checker & Slip Gauges L.C. 0.05mm 29.5 µm 30.0 µm Dial / Electronic L.C. 0.02mm 12.5 µm 13.5 µm 2.

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that SP Metrology System Thailand Co., LTD 88/115

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service Issue No: 028 Issue date: 10 pril 2018 ccredited to 6 Banner Park Wickmans Drive Coventry CV4 9X Contact: Keith rnold Tel: +44 (0)2476 426 316/317

More information

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date Last Amended on 11.11.2014 Page 1 of 6 I. DIMENSION 1. Dial/ Digital Vernier Caliper $ L.C.: 0.01mm Φ 0 to 200 mm 7.5 µm Using Slip Gauge Set & L.C.: 0.01mm Φ 0 to 300 mm 12.17 µm Using Slip Gauges & Caliper

More information

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6 Last Amended on - Page 1 of 6 I. DIMENSION 1. Vernier Caliper (Digital/ Dial/ Scale) $ L.C.: 0.01 mm 0 to 150 mm 7.7 µm Using Caliper Checker 0 to 200 mm 8.1 µm 0 to 300 mm 9.3 µm 0 to 600 mm 13.9 µm 2.

More information

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal Last Amended on 23.09.2014 Page 1 of 9 I. DIMENSION 1. GAUGE BLOCKS $ 0.5 mm to 25 mm 25 mm to 50 mm 50 mm to 75 mm 75 mm to 100 mm 2. LENGTH BAR $ Upto 300 mm 300 mm to 600 mm 300 mm to 1000 mm 0.11µm

More information

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10µm Φ 0 to 300 mm 13 µm Using Caliper Checker; & T.C. Gauge Block Set by Comparison L.C. :- 20µm 0 to 1000 mm 22 µm Using Caliper Checker;

More information

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date Last Amended on 18.01.2016 Page 1 of 7 I. DIMENSIONS 1. CALIPER $ (Vernier, Dial, Electronics) L.C.0.01 mm up to 1000mm 24 µm Using Caliper Checker / L.C.0.02 mm up to 600mm 19 µm Length Bars /Slip Gauges

More information

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra Last Amended on - Page 1 of 10 I. DIMENSION (Basic Measuring, Gauge etc.) 1. PLAIN PLUG / WIDTH/ DEPTH/ Upto 100 mm 1.9 µm Using Electronic FLUSH PIN GAUGE DIAMETER /WIDTH / DEPTH $ 100 mm to 300 mm 3.8

More information

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1 Calipers $ Up to 600 mm 10.4 µm Using Caliper Checker by Up to 1000 mm 13.2 µm Using Long Slip Gauge by 2 Height Gauges $ Up to 600 mm 12.8 µm Using

More information

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date Last Amended on - Page 1 of 11 I. DIMENSIONS 1. SLIP 0.5 mm to 25 mm 0.25 μm Using Slip Gauge (K-Grade) & > 25 mm to 50 mm 0.34 μm Double Probe Comparator > 50 mm to 75 mm 0.46 μm > 75 mm to 100 mm 0.58

More information

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER (Vernier/Dial/Digital) L. C. : 10µm Φ 0 to 600 mm 16 µm Using Caliper Checker & External Micrometer by 2. DEPTH GAUGE (Vernier/Dial/ Digital) L. C.

More information

Accredited Laboratory

Accredited Laboratory Accredited Laboratory A2LA has accredited CAL-RITE CORPORATION Naperville, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International

More information

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager IAS Accreditation Number Accredited Entity Address CL-128 1375 S. Acacia Avenue Fullerton, CA 92831 William Warner, Quality Manager Contact Name Telephone +1 (714) 638-2322 Effective Date of Scope July

More information

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6 Last Amended on - Page 1 of 6 I DIMENSION 1. Caliper $ (Vernier/Dial/Digital) LC : 0.01mm 0 to 600 mm 0 to 1000 mm 12.2 µm 13.3 µm Using Caliper Checker, Slip Gauge Block & 2. Depth Caliper $ (Vernier/Dial/Digital)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Data Weighing Systems 255 Mittel Drive Wood Dale, IL 60191 Steven A. Thomas 800-397-6301 CALIBRATION Valid to: September 22, 2019 Certificate Number: L1114-1

More information

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra Last Amended on 12.09.2014 Page 1 of 7 I. MASS 1. Weights $ (Conventional Mass) 1 mg 0.015 mg Using Weights of 2 mg 0.015 mg accuracy Class F1 and 5 mg 0.015 mg 10 mg 0.015 mg 20 mg 0.020 mg 50 mg 0.020

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAL-RITE CORPORATION 1665 Quincy Avenue, Suite 103 Naperville, IL 60540 Michael Crosby Phone: 630 355 1522 CALIBRATION Valid To: December

More information

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1. VERNIER CALIPER $ L.C. 0.01mm 0 to 300 mm 0 to 600 mm 0 to 1000 mm 8 µm 14 µm 16 µm, Slip Gauge Accessories, Gauge Block L.C. 0.02 mm 0 to 1500 mm

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORYACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

... CALIBRATION SERVICES PRICELIST. M&B Calibr. Accredited calibration company. No according to ČSN EN ISO/IEC

... CALIBRATION SERVICES PRICELIST. M&B Calibr.   Accredited calibration company. No according to ČSN EN ISO/IEC M&B Calibr... CALIBRATION SERVICES PRICELIST Accredited calibration company No. 2301 according to ČSN EN ISO/IEC 17025. Experience since 1991 Guaranteed quality Professional attitude www.mbcalibr.cz You

More information

Small Tool Instruments and Data Management

Small Tool Instruments and Data Management Small Tool Instruments and Data Management Gauge Blocks Pages 302 311 Calibration instruments Pages 312 319 301 Basic information on gauge blocks Characteristics of Mitutoyo gauge blocks: Mitutoyo, at

More information

MALAYSIAN STANDARD QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS (FIRST REVISION) (ISO 9001:2008, IDT) (PUBLISHED BY STANDARDS MALAYSIA IN 2009)

MALAYSIAN STANDARD QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS (FIRST REVISION) (ISO 9001:2008, IDT) (PUBLISHED BY STANDARDS MALAYSIA IN 2009) MALAYSIAN STANDARD MS ISO 9001:2008 QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS (FIRST REVISION) (ISO 9001:2008, IDT) (PUBLISHED BY STANDARDS MALAYSIA IN 2009) ICS: 03.120.10 Descriptors: quality management,

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date Last Amended on 09.12.2016 Page 1 of 8 I. DIMENSION (Basic Measuring, Gauge etc.) 1 LENGTH GAUGE/SETTING ROD $ Up to 100 mm >100 mm to 500 mm 1.5 µm 7.20 µm Using ULM, Gauge Block grade- 0 & Electronic

More information

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT October 17, 2017 VIA EMAIL Link Engineering Company Jim Villella 401 Southfield Road Dearborn, MI 48120 Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT-1997.01, ACT-1997.02

More information

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX 77060 Gavin Lewis 832-428-2737 In recognition of a successful assessment to ISO/IEC 17025:2005

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MNP CORPORATION TECHNICAL AND RESEARCH SERVICES 1 (Corporate Facility) 44225 Utica Road Utica, MI 48317 Chad Clifford Phone: 586 254 1320 MECHANICAL Valid To:

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Torreón, Coahuila, México C.P. 27019 (Hereinafter

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT CLEVELAND 5405 East Schaaf Road Cleveland, OH 44131 Jeffry J Smith Phone: 216 524 1450 Jeffry.Smith@element.com MECHANICAL Valid To: October 31, 2018

More information

Price List. Calibration Fee

Price List. Calibration Fee 3/4-5 Moo 3, Klong 5, Klong Luang, Pathumthani, 110, Thailand Tel. +66 577 5100 (Please contact : Customer Service Section Ext. 3101, 310) Fax. +66 577 3659 E-mail : cs@nimt.or.th Website : http://www.nimt.or.th

More information

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & KS Q ISO/IEC 17025-2006 Korea Instrument Co., Ltd. Branch 45, Gwangjang-ro 56beon-gil, Sasang-gu, Busan 46976 Phone : 051-322-0880, Fax : 051-322-4066, E-mail

More information

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on Last Amended on 12.08.2016 Page 1 of 7 I. DIMENSION (Basic Measuring, Gauge etc.) 1. CALIPER $ (Vernier / Dial / Digital) L.C.: 10 µm ф L.C.: 50 µm ф Upto 600mm 13 m Using Gauge Block Set Grade 0 (Carbide);

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RIVERVIEW CALIBRATION SERVICES, LTD 5706 Veto Road Belpre, OH 45714 J. Michael Pennell Phone: 740 678 8625 CALIBRATION Valid To: July

More information

MT SERIES COUNTER FLOW COOLING TOWER

MT SERIES COUNTER FLOW COOLING TOWER MT SERIES COUNTER FLOW COOLING TOWER Environment Friendly Power Safe High Performance Compact Genius Cooling Towers Sdn Bhd N. 35-2, 35-3, Jalan Puteri 4/1, Bandar Puteri, 47100 Puchong, Selangor, Malaysia.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: Unit 9 G B Quality ssurance (Consultants)

More information

+91-8048718949 Bearing & Tools Centre http://www.measuringtestinginstrument.com/ We are a renowned dealer and supplier of a wide assortment of precision engineered testing and measuring equipment. Our

More information

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6508-2 Third edition 2015-03-01 Metallic materials Rockwell hardness test Part 2: Verification and calibration of testing machines and indenters

More information

Lever Type Dial Indicators Dial Test Indicators SMALL TOOL INSTRUMENTS AND DATA MANAGEMENT

Lever Type Dial Indicators Dial Test Indicators SMALL TOOL INSTRUMENTS AND DATA MANAGEMENT Lever Type Indicators Test Indicators SMALL TOOL INSTRUMENTS AND DATA MANAGEMENT Drastically Enhanced Durability, Sensitivity and Visibility Lever Type Indicator Test Indicator Crystal for readability

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 EUSTIS CO., INC./PYROCOM CALIBRATION LAB 12407-B Mukilteo Speedway Lynnwood, WA 98087 Bill LeMesurier Phone: 425 423 9996 CALIBRATION

More information

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005 aboratory Metrology aboratory, CMTI, Central Manufacturing Technology ast Amended on 22.09.2016 Page 1 of 15 I. DIMENSION (Basic Measuring, Gauge etc.,) 1. ANGE GAUGE BOCKS $ 0 to 90 2.8 arc sec Using

More information

Welcome to Garber C O R P O R AT E O V E R V I E W

Welcome to Garber C O R P O R AT E O V E R V I E W CORPORATE OVERVIEW Garber Metrology is one of the only companies in the Mid-Atlantic Region that combines full service weighing solutions, a wide range of calibration /metrology services and a broad scope

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EMPIRE SCALE CORPORATION d.b.a. PRECISION SCALE & BALANCE d.b.a. EMPIRE SCALE & BALANCE 140 Rotech Drive Lancaster, NY 14086 Margery

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,

More information

OPPORTUNITY FOR PRECISION: THE MITUTOYO SPRING PROMOTION

OPPORTUNITY FOR PRECISION: THE MITUTOYO SPRING PROMOTION OPPORTUNITY FOR PRECISION: THE MITUTOYO SPRING PROMOTION FROM APRIL 1 THROUGH MAY 31, 2015 GENERAL PRE1316 U-WAVE Measurement Data Wireless Counication System Counication distance approx. 20 m Software

More information

High efficiency third generation screw airend Efficiency comparison chart of screw airend rotor by generations

High efficiency third generation screw airend Efficiency comparison chart of screw airend rotor by generations High efficiency third generation screw airend Efficiency comparison chart of screw airend rotor by generations Energy saving modulation control 0~100% Power consumption (%) First generation Second generation

More information

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR This is to attest that PROMPT ENGINEERING P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements of AC204, IAS Accreditation

More information

Cetemet, your ally for your innovative ideas

Cetemet, your ally for your innovative ideas Cetemet, your ally for your innovative ideas METROLOGY Lab CLIMATE TESTS Lab WELDING AND MATERIALS Lab METROLOGY Services Metrology services 3D Digitizing for dimensional control and reverse engineering

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CRYSTAL ENGINEERING CORPORATION, AN AMETEK INC. COMPANY 708 Fiero Lane, Suite 9 San Luis Obispo, CA 93401 Janine White Phone: 805 595

More information

Bore Gage. Inside Diameter Measurement. Small Tool Instruments and Data Management

Bore Gage. Inside Diameter Measurement. Small Tool Instruments and Data Management Small Tool Instruments and Data Management Inside Diameter Measurement Bore Gage Bulletin No. 2005 NEW Best-selling range of bore gages now offers better accuracy, user-friendliness and durability Bore

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 1440 Prudential Drive Dallas, TX 75235 Timothy R. Detten Phone: 214 638 1808 CALIBRATION Valid To: July 31, 2018 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BUREAU VERITAS CONSUMER PRODUCTS SERVICES MEXICO, S.A. DE C.V.-PUEBLA 1 Circuito del Sol 3905-01 Colonia Nuevo Amanecer Puebla, Puebla 72400, Mexico Alicia

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Monterrey, Nuevo León, 64920 (Hereinafter called the

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane

More information

Driving Excellence for Mutual Success TECHFAST PRECISION SDN BHD

Driving Excellence for Mutual Success TECHFAST PRECISION SDN BHD TECHFAST PRECISION SDN BHD page - 1 - TECHFAST PRECISION SDN BHD DRIVING EXCELLENCE FOR MUTUAL SUCCESS page - 2 - CORPORATE INFORMATION Listing Date : 6 th June 2005 Authorized Capital : RM 50,000,000.00

More information

APPLICATION FOR PRODUCT / ECO-LABELLING CERTIFICATION. GPS Coordinates. GPS Coordinates. Fax No. H/P No.

APPLICATION FOR PRODUCT / ECO-LABELLING CERTIFICATION. GPS Coordinates. GPS Coordinates. Fax No. H/P No. epcs/for/01-2 SIRIM QAS International Sdn. Bhd. (410334-X) SIRIM Complex, No. 1, Persiaran Dato Menteri, P.O. Box 7035, 40700 Shah Alam, Selangor Darul Ehsan, Malaysia. Tel: 603-5544 6402 Fax: 603-5544

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCHAP LABORATORY SERVICES, LLC 17309 Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone: 616 846 6530 MECHANICAL Valid To: June 30, 2020 Certificate Number:

More information

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1 Rev. 02 07/07/2015 CATALOGUE - CALIBRATION SERVICES 1 OVER 100 ITEMS We are proud to present to you our new catalogue for 2015. In the following pages we present more than 100 instrument types, which we

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Chamber Commerce: 06073326 Location(s) where activities are performed under accreditation ad Office Smaragdstraat 7 7554 TD ngelo OV The Netherlands Location Abbreviation/ location Smaragdstraat 7 7554

More information

Certificate of Registration

Certificate of Registration Certificate of Registration PRODUCTION AND MANAGEMENT SYSTEM This is to certify that Company Name United Plantations Berhad Management Unit Name United International Enterprise Palm Oil Mill Company Address

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Garber Metrology Weighing Solutions & Precision

More information

UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS

UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS EDUCATION A TECHNICAL PRESENTATION FROM THE LEADING MANUFACTURER OF METROLOGY INSTRUMENTS Bulletin No. 2183 EDU-14003A-H Mitutoyo Institute of Metrology

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11140 18 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.11.2014 to 05.11.2019 Holder of certificate: Fraunhofer

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: June

More information

Portable Hardness Tester TIME Ultrasonic Contact Impedance (UCI) Method

Portable Hardness Tester TIME Ultrasonic Contact Impedance (UCI) Method Portable Hardness Tester TIME5620 -Ultrasonic Contact Impedance (UCI) Method Larger, clear screen displays probe information, battery information, the average, maximum, minimum readings of select hardness

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: September

More information

HELMTECH LEADING IN QUALITY. Perak Branch. Headquarters. Sarawak Branch. Helmtech Engineering (M) Sdn Bhd P

HELMTECH LEADING IN QUALITY. Perak Branch. Headquarters. Sarawak Branch.  Helmtech Engineering (M) Sdn Bhd P Headquarters Perak Branch Helmtech Engineering (M) Sdn.Bhd No.2, Jalan Anggerik Mokara 31/64, Seksyen 31 Kota Kemuning, 40460 Shah Alam Selangor D.E, Malaysia Phone : 03 5122 9869 (H.Line) Phone : 03 5122

More information

Check Points. for Measuring Instruments

Check Points. for Measuring Instruments Check Points for Measuring Instruments Introduction Measurement the word can mean many things. In the case of length measurement, there are many kinds of measuring instruments and their corresponding measuring

More information

TRI-STATE INSTRUMENT SVC, INC

TRI-STATE INSTRUMENT SVC, INC CALIBRATION RATE POLICY AND PRICING 2017 Typically, compliance with ISO-900x and TS 16949 specifications require LONG FORM calibration reports in the following formats. Format #1 -- Before Adjustment or

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Florida Department of Agriculture Metrology Laboratory 3125 Conner Blvd. Lab #2 Tallahassee, FL 32399-1650 Ms. Amy Smith Phone: 850-921-1570 Fax: 850-921-1593

More information

1 of 14. Micron Machines Technology Sdn. Bhd. Okamoto Precision Grinding Machine. Okamoto Precision Grinding Machine

1 of 14. Micron Machines Technology Sdn. Bhd. Okamoto Precision Grinding Machine. Okamoto Precision Grinding Machine Micron Machines Technology Sdn. Bhd. CYLINDER GRINDER INTERNAL GRINDER MODEL : MAX15-ID SPECIFICATION i) Swing over Table : 600mm ii) Internal diameter to be ground : Ø6 ~ Ø150mm iii) Swing inside workpiece

More information

Design and application

Design and application Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow

More information

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5 National Research Council Conseil national de recherches Canada Canada Measurement Standards and Science Science des mesures et étalons Calibration Laboratory Assessment Service CLAS Certificate Number

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: UNEX/HYTORC, 333 Route 17 North, Mahwah, NJ 07430

More information

Amruta Electronics Corporation

Amruta Electronics Corporation +91-8048603192 Amruta Electronics Corporation https://www.indiamart.com/amruta-electronics/ Our organization is known in the market for importing and trading an advanced range of Ultrasonic Detector &

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EQUIPO AUTOMOTRIZ AMERICANA S.A. DE C.V. Lib. Carlos Salinas de Gortari #198 Norte Cd. Frontera, Coahuila C.P., Mexico 25618 Abelardo Castilla Abelardo.Castilla@takata.com

More information

Fall Savings! HUGE SAVINGS!

Fall Savings! HUGE SAVINGS! Fall Savings! ROCKWELL HARDNESS TESTER PACKAGES Valid: From October 2nd to December 22nd 2018 Prices Subject to Change without Notice & Stock Availability. Some items may not be exactly as shown 13% Without

More information

HDI Range Electric Lubrication Pumps

HDI Range Electric Lubrication Pumps HDI Range Electric Lubrication Pumps Timken ILS Ltd - Heavy Duty Industrial Lubrication Systems 1 The HDI Family Electric Centralized lubrication Pumps with 3, 6, 9 & 15kg Perspex Reservoirs * * HDI 3

More information

Influence of mounting tube diameter on anemometer output

Influence of mounting tube diameter on anemometer output Influence of mounting tube diameter on anemometer output In cooperation with: Adolf Thies GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Deutsche WindGuard Wind Tunnel Services GmbH Oldenburger Str.

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Mexical Metrología, S.A. de C.V. Tecnología de Materiales,

More information

COMPANY PROFILE THE CCTV AND SECURITY SYSTEM COMPANY

COMPANY PROFILE THE CCTV AND SECURITY SYSTEM COMPANY TM COMPANY PROFILE THE CCTV AND SECURITY SYSTEM COMPANY ZASHTECH SDN BHD 1263902-U B-12-1 Jalan Serai Wangi 16/G, Alam Avenue 1 Seksyen 16, 40200 Shah Alam, Selangor Email: enquiry@pasangcctv.com.my https://www.pasangcctv.com.my

More information

6-8 Stainless Steel Submerged Centrifugal Pump

6-8 Stainless Steel Submerged Centrifugal Pump 6 & 8 BHE(L) 6-8 Submerged Centrifugal Pump IMENSION PUMP 8BHE 77 imension (mm) 86 BHE 77-2 86 BHE 77-3 86 BHE 77-4 86 BHE 77-5 86 BHE 77-6 86 BHE 77-7 86 BHE 77-8 86 BHE 77-9 86 BHE 77-10 86 BHE 77-11

More information

Soode (J) Sdn. Bhd. Company Profile. Specialists Of Original-technology & DEvelopment

Soode (J) Sdn. Bhd. Company Profile. Specialists Of Original-technology & DEvelopment Soode (J) Sdn. Bhd. Company Profile Specialists Of Original-technology & DEvelopment Last update: 18 JULY 2018 Introduction Corporate Data Company Name Co. No Established Chairman Managing Director Executive

More information

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32 Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve Steam Solenoid Valve 1 of 32 Stainless Steel Solenoid Valve Stainless Steel Flange End Solenoid Valve 2 of 32 Solenoid Pilot Operated Valve For

More information

YOUR MITUTOYO PROMOTION

YOUR MITUTOYO PROMOTION Action valid from 1st April to 31st May 2014. We reserve the right to make technical changes and developments; these prices only apply to business customers; all prices are understood to be net prices

More information

Small Tool Instruments and Data Management

Small Tool Instruments and Data Management Small Tool Instruments and Data Management Dial Gauge Stands Pages 268 272 Comparator Stands Pages 273 274 Joint Magnetic Stands Concentricity testers Pages 275 280 Angulometers, steel squares Pages 281

More information