The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Size: px
Start display at page:

Download "The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3"

Transcription

1 The RCS-6V kit Page of Contents Page 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3 2. The principle of the system 2.1. How the load measurement system works The reference height 6 3. Mounting the RCS-kit 3.1. Part in the kit Mounting the sensor Mounting the indicator Mounting the cable Placing the stickers The machine sticker Placing the batteries Power supply by truck battery (option) Setting the capacity and the graduation 4.1. Determining the capacity of the truck Setting the graduation Calibration 5.1 Attention! Before you begin calibration Zero point adjustment Calibration Taking the system into use 6.1 Turning the system on and off Using the reference height How can I weigh as accurately as possible? The indicator The touch panel The functions of the load measurement system 7.1. Zero point correction Gross weighing Net weighing: automatic tare Net weighing: manual tare entry Totalling 19 1

2 8. Changing the calibration time for more accurate weighing Specifications and options 9.1. Specifications Options Most frequently occurring problems 10.1 The display does not freeze the weight value, but stays unstable The display freezes or gives an incorrect weight Inaccurate weights are shown after installation or first use Weighing errors on systems which are already in use 23 2 Rev

3 1. THIS BOOK This book explains how the hydraulic measuring system can be used and how the parts in the kit are mounted Warning & safety measures When using the RCS please observe carefully the instructions and guidelines contained in this manual. Always perform each step in sequence. If any of the instructions are not clear, please contact RAVAS. - All safety regulations that apply on the truck remain valid and unchanged - RAVAS is not responsible for any physical harm done to the operator because of the presence of the indicator in the cabin. - Any modifications done to the system must be approved in writing from the supplier, prior to any work being completed. - It is the sole responsibility of the purchaser to train their own employees in the proper use and maintenance of this equipment. - Do not operate this unit unless you have been fully trained of its capabilities. - Check the accuracy of the scale on a regular basis to prevent faulty readings. - Only trained and authorized personnel are allowed to service the scale. - Always follow the operating, maintenance and repair instructions of this truck and ask the supplier when in doubt. - RAVAS is not responsible for errors that occur due to incorrect weighings or inaccurate scales. - No weighing operations are allowed if any persons or objects are in the vicinity; around, under or close to the load. min -10 C 15 F max 40 C 105 F IP What can I do with the RCS-kit? The RCS is a hydraulic measuring system for forklift trucks and stackers. By measuring the oil pressure in the lifting cylinder an indication is given of the weight lifted. Measuring the oil pressure is very precise but mechanical parts in the lifting mechanism and, for example, the position of the mast can restrict the accuracy A few tips It is possible to increase the accuracy. Here are a few tips on own to ensure that the systems weighs as precisely as possible. 3

4 Keep the mast vertical while weighing (an angle of 2 to 3 degrees has almost no affect); Put the centre of gravity of the load in the middle of the forks; Weigh at a set height; Do not take the forks to the reference height (the height at which the stickers on the carriage plate and mast are opposite each other) too fast. It is best to take the forks above the reference height and then lower them to the reference height. Do this slowly, without a sudden stop; When the reference height is reached the weight is frozen in the display. The display will not freeze for loads underneath 20 graduations; on a system with a graduation of 5kg, for example, this is 100kg; Make sure that the system is first unloaded, before a new weighing is begun. Chapter 6.2. describes in more detail how to ensure that the load measurement system is more accurate. The hydraulic measuring system has a maximum tolerance of 2% of its capacity. At a capacity of 2500 kg, that is a difference of 50kg! When used correctly, the accuracy is usually significantly higher. 4

5 2. THE PRINCIPLE OF THE SYSTEM 2.1. How the RCS-system works The load measurement system measures the oil pressure with an oil pressure sensor. The pressure in the lifting system depends on the load on the fork lift system. Measuring the oil pressure is very precise but mechanical parts in the lifting mechanism and, for example, the position of the mast can restrict the accuracy. The friction/resistance of the rolls, with which the carriage plate moves in the mast, has a big influence on the weighing. The resistance in the rolls, through dirt or bad bearings, increases the inaccuracy that is created by: internal leaks in the oil circuit; non-central loading of the forks (the load is not in the middle of the forks); the difference due to slow or fast approach of the reference height. The slip and stick effect causes less repeatablility, and thus less accuracy. Repeatability means that when the same load is weighed several times, the same weight is shown in the display. 5

6 2.2. De reference height To reduce the influence of the condition of the mast and the cylinder, the weighing is always performed at the same height. To ensure this, stickers are placed on the mast and carriage plate to clearly mark the reference height at which the weighing should occur. First lift the forks past the reference point and then lower the load to the point where the stickers are opposite each other. This results in the optimal accuracy. For the best result from the system, that is, for minimal influence from the friction and resistance in the mast, the weighing should take place with the mast in the vertical position!* * An angle of 2 to 3 degrees has almost no influence. The centre of gravity of the load has to be exactly in the middle of the forks. If the centre of gravity is on the ends of the forks, or if one fork is loaded more than the other, then the friction in the mast is significantly higher and the measurement will be less accurate. Chapter 6.2. describes how to weigh with the most accuracy. 6

7 3. MOUNTING THE RCS-KIT 3.1. The parts in the kit Sensor Protective cover for the sensor cable Indicator Stickers to mark the reference height Penlight batteries model AA Machine stickers 7

8 3.2. Mounting the sensor Before you start: Read chapter 2. The way the system works is described there. Understanding how the system works will make mounting the components easier. Ensure that there is no pressure on the high-pressure hose. The sensor is mounted with a T-piece in the high-pressure hose, between the valves and the cylinder. The connection on the sensor is G¼ BSP male. Mount the T-piece so that the sensor and the cable connection are pointing downwards. This will prevent air getting into the sensor. 1. Sensor 2. Sensor cable with connector 3. Sealing ring 4. T-piece (not supplied with the kit) The sensor has to be mounted, as shown, with the cable connector pointing downwards. Protect the cable against moving, sharp or warm parts with the supplied protective cover. Choose a place to mount the sensor: Mount the sensor in the pressure hose that steers the cylinder. The cylinder moves the carriage plate. Normally there is only one pressure hose. Do not mount the sensor too close to the engine. Large differences in temperature can influence the accuracy of the system. If the truck is used intensively, a piece of pipe or hose of ± 50 cm can be mounted between the sensor and the T-piece. The sensor is sensitive to temperature differences. If the moving oil becomes warm, the standing oil in this pipe or hose will remain cool. The sensor will not be effected by temperature differences. Place the sensor close to the cylinder. There is often more room there and it is easier to reach. Choose, if possible, a place to mount the sensor where there are the least few steering and safety valves between the sensor and the cylinder. 8

9 3.3. Mounting the indicator The indicator is supplied with a steel mounting bracket. This bracket can be used to hang the indicator up or mount it standing. Choose the correct place to mount the indicator and make sure that: the indicator is visible and within reach of the chauffeur; the indicator is hung high enough so that the chauffeur does not hit his head; the indicator does not restrict the movement of the steering handles; there is still sufficient leg room; the indicator does not restrict the access to the engine or the battery Mounting the sensor cable When mounting the cable, it is important that the cable is kept tidy and protected. Keep the cable out of sight as much as possible to prevent the possibility of damage to the cable. It may be necessary to thread the cable through small openings, through which the 18mm connector does not fit. In that case it is possible de dismount the cable and the connector from the indicator. The photo s show how that can be done. The system is supplied with a protective cover for the cable. This can be used where: the cable is near parts of the lift truck that become hot; the cable is mounted near moving parts. 9

10 3.5. Placing the stickers Two stickers are supplied with this kit. The arrow stickers are used to show the reference height. One of the stickers is placed on the mast and one on the carriage plate. The photo shows where the reference height is on the truck. Attention: Make sure that the chauffeur can see the stickers; Make sure that there is a minimal distance between the two arrows. The larger the distance, the more difficult it will be to gauge the height accurately; Choose a practical height: not too high, because then lifting will take more time. Moreover, it may be dangerous to lift heavy loads too high The machine sticker As described in the CE directive for weighing systems, a machine sticker has to be applied to the weighing system. The sticker shows the capacity and the graduation. The stickers that are supplied with the kit are suitable for different capacities. Apply the correct sticker as shown: 3.7. Placing the batteries 4 AA penlight batteries are needed, it does not matter which type. The batteries supplied are not rechargeable. Loosen the screws at the front of the indicator. Remove the front part of the indicator. Be careful for the cable connections! Make sure you do not pull at them. Place the batteries. Be careful not to damage the system and place the batteries correctly. Pay attention to the + and signs. Screw the indicator closed again. 10

11 3.8. Power supply by truck battery (option) If the indicator is equipped with an integrated 12V power regulator, which can be verified by reading the label on the indicator housing, then the indicator must be connected directly to the truck battery. The 12V power regulator can be ordered as an option _ EU Brown Blue US Red Black 4. SETTING THE CAPACITY AND GRADUATION 4.1. Determining the capacity of the truck The graduation of the indicator depends on the capacity of the lift truck. The European directives for weighing systems state that the machine stickers should show the producer, the capacity and the graduation. The kit contains a number of stickers with different capacities and graduations. For a capacity of 2500 kg the weight is shown in 5 kg steps; For a capacity of 5000 kg the weight is shown in 10 kg steps; For a capacity of kg the weight is shown in 20 kg steps.!!! IMPORTANT!!! If the lifting capacity of the forklift truck is different then the above-mentioned e.g kg or 3000 kg, a higher capacity should be chosen. For 1500 kg the capacity will be 2500 kg; for 3000 kg it will be 5000 kg. If you choose a setting and machine sticker with a smaller capacity, and therefore a smaller graduation, then the measurement range and accuracy will not be in accordance with the specifications. The standard setting of the indicator is a capacity of 2500 kg and a graduation of 5 kg. The following procedure should be followed to change the settings. 11

12 4.2. Changing graduation To go to the parameter menu: Switch off the indicator. Press 23 seconds on the on/off key. (Don t let go!) Wait till the indicator displays P01. Use parameter (P02) to enter the correct graduation: Use the keys and to go to P02. Confirm with (0/T). The indicator shows the graduation: 5 (5 kg). Modifying the graduation: Use the and to change the graduation to: 10 for systems with a capacity of 3000 kg to 5000 kg. 20 for systems with a capacity of more than 5000 kg. Confirm with (0/T). The indicator shows P03. Parameter (P05) to enter the correct weighing capacity: Use the keys and and go to P05. Confirm with (0/T). The indicator shows the capacity (2500 kg) of which the digit 5 is flashing. Use the keys and and change this value to 0. Confirm with (0/T). The indicator shows the capacity of which the digit 2 is flashing. Use the keys and and change the value to: 3 for 3000 kg or 5 for 5000 kg or 0 for kg Confirm with (0/T). The indicator shows the capacity of of where the 0 on the left is flashing. When a capacity of kg is needed, use the keys and and change this value to 1. Confirm with (0/T). The indicator shows P06. To leave the parameter menu: Press 3 seconds on the key (0/T) to leave the parameter menu and return to the load measurement mode. 12

13 5. CALIBRATION 5.1. Attention! Before you start calibration: The calibration of the system should take place at the reference height, as described in chapter 2.2. The mast needs to be vertical when calibrating and measuring loads. When calibrating a calibration weight is needed of 50 to 75% of the capacity of the lift truck. When calibrating at the client, weigh the pallet on another weighing system. That weight can be used as the calibration weight. Make sure, when calibrating, that the centre of gravity is in the middle of the forks Zero point calibration Make sure the system is unloaded and the mast is vertical. Switch the system on. Lift the system to past the reference height and lower it to the reference height. Push the (0/T) key for about 8 seconds. The display counts down from AF 08 to AF 00. The indicator shows which percentage of the total capacity has been zeroed, e.g. AP 6.4. This percentage should not be higher than 40. The zero point has been defined, the system automatically returns to standard weighing mode. Check if the zero point is stable. Lower the carriage plate to the reference height a few times and check whether the zero point (± one or two graduations) returns Calibration Push the PT key for 18 seconds. The display will go blank until calibration mode has been reached. The indicator shows the value of the first calibration point, the lowest indication bar is flashing. Load the load measurement system with a known weight. The cursor keys are used to enter the weight on the forks into the system. Press the (0/T) key shortly. The first segment starts flashing. Use the and keys to change the segment. Confirm the value by pressing the (0/T) key. The second segment starts flashing. Use the and keys to change the segment. Press the (0/T) key. Repeat this procedure until all the segments show the correct value for the calibration weight. When each segment has been corrected, the lower indication bar will flash again. 13

14 If this is not the case, press the (0/T) key until the lower indication bar starts flashing. ATTENTION: the following two points need to be executed in quick succession. Lower the forks to reference height. Confirm the entered weight immediately by pressing the (0/T) key for 3 seconds. The display counts down from AF 08 to AF 00, the first calibration point has been set. Leaving the calibration mode: Leave calibration mode by pressing the or key until AP XX appears. This number indicates the calibration sensitivity percentage, e.g. AP 07. Return to standard load measurement mode by pressing the (0/T) key until the display goes blank. Turn off the load measurement system and turn it back on again. Weigh the calibration weight a few times by lowering it to the reference height. The load measurement should be repeatable, within the tolerances of the system, which is 2% of the capacity of the load measurement system. That means that, at a capacity of 2500 kg, the difference will not be more than 50 kg. If the weight result is not repeatable, repeat the whole calibration procedure, paying attention to the following aspects: Do not vary the speed with which you approach the reference point; The centre of gravity has to be in the middle of the forks; Make sure the mast is vertical. If, after the two or three attempts, the weighings are not repeatable, refer to Chapter 8: Optimal calibration or Chapter 10: Most frequently occurring problems.. 6. TAKING THE SYSTEM INTO USE 6.1. Turning the system on and off The load measurement system is turned on with on and off key on the indicator. The system will turn off after 3 minutes. This saves the power of the battery. When the batteries are empty, LO-BA will flash in the screen of the indicator. It is still possible to perform a number of weighings before the system turns off completely. Attention! It is only possible to press a key when the weight is stable in the display. The load stable indication can be seen in the indicator display. If the load is not stable, the keys will not react. This prevents mistakes. Weighing or adding a moving load is not accurate. 14

15 6.2. Using the reference height Lift the forks a little bit higher than the point at which the stickers are on the carriage plate and lower them to the reference height. For more information on the reference height see chapter How can I weigh as accurately as possible? As explained, the hydraulic measuring is very precise but the accuracy is influenced by the mechanical parts, for example, through dirt of bad bearings in the mast, or internal leaks in the oil circuit. Or because the load to be weighed is not in the middle of the forks. Another cause is that the system is not used correctly. It is possible to increase the accuracy. How? By keeping the mast vertical during the load measurement. (An angle of 2 to 3 degrees has almost no influence); By putting the centre of gravity in the middle of the forks; By measuring the load at a fixed height; By not taking the forks to the reference height to fast. It is best to lift the forks past the reference height (the height of the stickers on the carriage plate and mast) and then lower them to the reference height. This should be done slowly, without sudden stop; When the reference height is reached the weight is fixed on the display. At this time the weights are added by the system; The display will not freeze for loads underneath 20 graduations; on a system with a graduation of 5kg, for example, this is 100kg. These weighits will also not be added to the total. Make sure that the system is unloaded before a new weighing is started. Calibrate the systems correctly. See chapter 5: Calibration. 15

16 6.4. The indicator Front indicator Display indications By means of three pointer bars the display of the indicator shows: The load measurement system (including load) is stable The weight shown is negative NET The display shows the net weight The following indications can be shown in the display: HELP 1 HELP 2 HELP 3 HELP 4 HELP 7 LO-BA The load measurement system has been overloaded. The zero point is below the originally calibrated zero point. See load measurement system calibration. Negative signal from the sensor. The tare value entered (manually) is too high. Press key PT again to delete this help message and key in a lower tare value. Signal from the sensor is too high. The batteries are (almost) empty. 16

17 6.5. The touch panel Each key has an operational and an entry function. Operational function zero setting and automatic tare Entry function confirm and digit to the left tare entry decreasing flashing digit totalling increasing flashing digit on / off!!! IMPORTANT!!! Operation of a key is not accepted unless the load measurement system is stable (and the load stable sign lights up). This means that the indicator only executes commands with a stable load. 7. THE FUNCTIONS OF THE RCS-SYSTEM 7.1. Correct zero point To check the zero point the forks have to be freestanding and they may not touch the ground. They should, of course, be empty. Lower the forks to the reference height and check whether the display on the indicator shows a zero. If not, press the 0/T key. On many systems (dependant on the condition of the lift truck) the display will stay on 0 kg between the lowest position (forks not on the floor) and, for example, a height of two meters. If this is the case, the forks do not have to be lowered to the reference height to check the zero point. This is also true when checking after a lifting or lowering movement. The zero point can be checked without further actions. 17

18 7.2. Gross weighing Before starting a new weighing, make sure that there is nothing on the forks. Check whether 0 kg is still shown on the display. See also the paragraph correct zero point. Lift the load past the reference height. See also chapter 2.2. Then lower the forks calmly to the point at which the reference height arrows are opposite each other. After a short time the display will show the load stable indication. With a load on the forks, it is possible to check whether the height at which the weighings take place is of influence is on the weight shown. If it is clear that there is little difference, and the accuracy is not of high importance, then it is possible to weigh at different heights, which can save time Net weighing: automatic tare The indicator offers the possibility to reset tare weights to zero automatically. This way added or subtracted weights can be determined. ATTENTION: It is not possible to do dosing with this load indication system! It is not possible to register the addition or subtraction of weight without returning to the reference height. Lower the load to reference height. Press the 0/T key. The indicator is set to zero. The "NET" pointer shows that a tare weight is activated. Place or remove the net load. The display shows the net value of the weighed load. When removing load, this is a negative value. By executing a zero setting in unloaded position, the system will return to the standard load measurement mode Net weighing: manual tare entry By pressing the PT key a tare can be entered. After a known tare weight, for example the packaging, has been entered, the net weight is shown on the display. This happens as follows: Make sure that the forks are unloaded (do not enter a tare value when the forks are loaded: this will decrease the measurement precision). Make sure the indicator indicates zero (correct the zero-setting if necessary by pushing the 0/T key). Activate the last entered tare value: Press the PT key. The display shows the current tare value. The digit on the right flashes. Press ENTER () for three seconds if the current tare value is required. 18

19 To enter a new tare value: Press the PT key. The display shows the current tare value. The digit on the right flashes. Press the key to go up a value or press the key to go down a value until the required value is reached. Press ENTER () to change the next value. Repeat this procedure until the required tare value is displayed. Press ENTER () until the last segment has stopped flashing. The tare weight is activated. The NET pointer lights up. When the system is loaded at this moment, the net value appears in the display. When the system is unloaded, the read-out displays the given tare value negatively Totalling The indicator offers the possibility to add up weighings and show the total weight. When a tare weight is active, the net weight is added up automatically. Adding new weights: Load the system. When the weight is stable, press the Σ key to add the weighed load to the total weight. The value of the display is stored and added in the memory. In turn, the indicator shows the sequence number (number of weighings) and the (sub)total. After a few seconds the system will automatically return to the standard load measurement mode. Check the total weight or print and reset: Press the Σ key for three seconds to refer to the total weight calculated thus far (without totalling). In turn, the indicator shows the sequence number (number of weighings) and the (sub)total current in the memory. After a few seconds the system will automatically return to the standard load measurement mode. You can now continue totalling. The memory can be erased by pressing the Σ key during the display of the total. If the system is equipped with a printer, an overview print is made. The display shows sequence number 00 and the total weight 0 kg. The system will automatically return to the standard load measurement mode. 19

20 8. CHANGING THE CALCULATION TIME TO IMPROVE THE ACCURACY When the load is lowered to the reference height the indicator software registers a peak and then a slow reduction in the oil pressure. During this period a number of calculations are made, after which the weight is shown, fixed and stable, on the display. This calculation time can be set. The default time is 4 seconds. If this time is increased the accuracy of the load measurement system is higher. The disadvantage, however, is that each load measurement takes more time. To change the calculation time, follow this procedure: To go to the parameter menu: Switch off the indicator. Press 23 seconds on the on/off key. (Don t let go!) Wait till: The indicator displays P01. Use parameter P01 to set the required calculation time: Enter with (0/T). The indicator shows: 04. Use the and keys and change this value to a maximum of 9 (nine seconds) or choose a lower calculation time. Enter with (0/T). The indicator shows P02. To leave the parameter menu: Press 3 seconds on the key (0/T) to leave the parameter menu and return to the load measurement mode. 9. SPECIFICATIONS AND OPTIONS 9.1. Specifications Maximum inaccuracy 2% of the capacity of the load measurement system (50 kg at a capacity of 2500 kg). The pressure sensor is suitable for lift trucks with a system pressure of 600 Bar. Water and dust proof according to the IP65 norm. System power through 4 AA penlight batteries, 2500 Ah. Autonomy is 450 hours, 2 years at 20 weighings per day. 20

21 9.2. Options Printer Roll printer for registration of exceptional weights and the total weight. Fixed power supply Instead of the use of AA penlight batteries, the system can be connected to the lift truck battery. These options cannot be added once the system is mounted and can only be bought with a new system. 10. MOST FREQUENTLY OCCURING PROBLEMS The display does not freeze the weight value, but stays unstable. Cause When you lower the forks to the reference marks then the indicator will measure a small peak in the hydraulic pressure when stopping this lowering action. At this moment a calculation is started which results in the weight value freezing in the display. When the reference height is approached too slowly then the indicator will not sense a pressure peak hence there will be no frozen weight reading in the display. The weight display will keep on counting down because of the characteristics of the hydraulic components and also because of the stick and slip effect caused by the roller friction in the mast. Solution lift the forks above the reference level and lower with slightly more speed to the reference height. The display will not freeze for loads underneath 20 graduations; on a system with a graduation of 5kg, for example, this is 100kg The display is locked up or gives totally wrong values Cause could be: a new calibration has been executed without deleting the old calibration values these need to be reset to zero before starting a new calibration. Without this multiple calibrations point will stay active. These points can be set to zero as listed below: Go to the calibration menu Press the PT key for about 18 seconds (this may be 8 seconds on older versions). The display will go blank until calibration mode has been reached. The indicator shows the value of the first calibration point, the lowest indication bar is flashing. Check whether the old calibration points are still active. If they are, set them to zero. Press the key. The middle bar is flashing; the second calibration point is displayed. 21

22 Use the and keys to change all segments, confirming the value per segment by pressing the (0/T) key, until each segment is set to zero. Press the key. The highest bar is flashing; the third calibration point is displayed. Use the and keys to change all segments, confirming the value per segment by pressing the (0/T) key, until each segment is set to zero. Press the key twice to return to the first calibration point. The lowest indication bar is flashing Incorrect weights are shown after installation or first use The system only works properly when the zero-point is stable and remains stable. When errors remain, despite a stable zero point, check the following points: Place a large load (¾ off the truck capacity) on the forks and weigh the load by lowering it to the reference height. Repeat that and check if the weight readings are repeatable NB errors until 2% are possible. If the repeatability test is positive, testing with one test load gives an accurate and consistent result, then you can proceed to test with multiple loads to check if the system is linear. Weigh 3 different loads i.e. +/- 500, 1000 en 2000 kg using another (accurate) weighing system and then use the load measurement system. (Also check if the different weights are repeatable). When all weights have the same percentage of error then the system has to be calibrated (again). When one of three loads is correct and one of the two others has an error of more than 2% only then it makes sense to execute a multiple point calibration, see also Chapter 8. The system shows irregular values: Cause High friction in the cylinder, mast, guiding strips or chain rollers. Solution Look where the friction is coming from and solve the problem. (Contact your forklift truck dealer). Cause Safety valves or valves, which control the lift and lowering sequence of the multiple cylinders, can be of influence on the pressure in the system. Solution Check if the error occurs after a certain action. For instance when the second or third mast is active, or certain valves are active. Taking all loads off the forks by resting the forks on the floor can cure the problem and it will also activate a new weighing. Check whether relocating the sensor could be a solution to the problem. 22

23 10.4. Weighing errors on systems which are already in use First check whether the errors are caused by incorrect use of the load measurement system, by following the instructions below. If the problems are not solved refer to Chapter Incorrect weights are shown after installation or first use. The error is consistent: Solution Check if the zero point is stable. Lift the forks with no load on just off the ground, set the display to 0 kg and move the forks a bit to check if the display stays on 0 kg. Small changes of 5 or 10 kg (one or two increments) are possible. Errors only occur at certain moments during the day: Cause Temperature differences. The hydraulic oil is heating up the sensor. The hydraulic oil now has less friction in the cylinders etc. Solution Mount the sensor using a piece of hose or pipe, a bit further away from the T piece and also away from the pump and/or the hydraulic circuit. The oil in the little hose or pipe is not flowing and will react as a temperature isolator so that the sensor will no longer heat up. Normally speaking, the change in friction cannot create errors greater then 2% of the scale capacity. The errors should stay within the specification of this hydraulic load measurement system. The error only occurs with certain operators of the system: Cause Operators use the system in their own way. Solution Train all operators to use the system in the same way. Then the system has to be calibrated in accordance with the way the system is used. The operators can choose if they lower the forks to the reference point quickly or slowly and then the calibration has to be done in the same way. If other methods are used than described in this manual, then the results can fall outside the accuracy specifications. 23

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017 Operator s Manual Fairbanks FH Series 2017 by Fairbanks Scales, Inc. All rights reserved 51393. Revision 1 06/2017 Amendment Record Fairbanks FH Series Operator s Manual Operator s Manual Document 51393

More information

User Manual. Rev USER MANUAL MForks 1

User Manual. Rev USER MANUAL MForks 1 User Manual Rev.27.09.11 USER MANUAL MForks 1 PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE If you have any queries concerning the duration and terms of the guarantee, please contact your supplier.

More information

Operators Manual. FHX Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 07/2017

Operators Manual. FHX Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 07/2017 Operators Manual FHX Series 2017 by Fairbanks Scales, Inc. All rights reserved 51395. Revision 1 07/2017 Amendment Record FHX Series Operators Manual Operators Manual Document 51395 Fairbanks Scales 821

More information

USER MANUAL iforks. Rev USER MANUAL iforks 1

USER MANUAL iforks. Rev USER MANUAL iforks 1 USER MANUAL iforks Rev.12.04.12 USER MANUAL iforks 1 PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE If you have any queries concerning the duration and terms of the guarantee, please contact your

More information

Top quality Plug & weigh

Top quality Plug & weigh FORKLIFT TRUCK SCALES iforks Completely wireless fork scale BENEFITS 5 Minutes installation Completely wireless: no cabling Digital calibration Weight correction for forklift mast tilt No de-rating of

More information

OWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1

OWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1 OWNERS MANUAL iforks Rev.18.02.09 OWNERS MANUAL iforks 1 PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE If you have any queries concerning the duration and terms of the guarantee, please contact

More information

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy: π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature

More information

Installation & Calibration

Installation & Calibration Installation & Calibration ED2-AT Series SkidWeigh System Lift Truck On-board Check Weighing With Accumulative Load Weight Total ED2-AT Series SkidWeigh V.1.1 General Installation Guide This ED2-AT Series

More information

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g) American Weigh Scales SC-Series User Manual SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 SC-Series Manual Thank

More information

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1 OPERATIONS MANUAL M-520 Please take the time to read these instructions before starting to use the scales Page 1 Contents Power supply 3 Specifications 3 Maintenance and general care 3 Key functions 4

More information

Instruction Manual Pallet Truck with Load Indicator

Instruction Manual Pallet Truck with Load Indicator Instruction Manual Pallet Truck with Load Indicator Note: Owner/Operator must read and understand this instruction manual before using the pallet truck with load indicator. RevA:04/007 Thank you for using

More information

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY: π H-4564 PALLET TRUCK SCALE WITH PRINTER 1-800-295-5510 uline.com AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY: 1. Temperature extremes Do not place in direct sunlight or near air conditioning

More information

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance TM ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance Scale Users Guide ISHTAA SCALES INC., INDIA www.ishtaascales.com 14 Content 1. Technical Data... 1 2. Installation... 2 3. Controls

More information

Compact Scales. Software Revision V1.25 & above

Compact Scales. Software Revision V1.25 & above Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:

More information

ECT Display Driver Installation for AP2 Module

ECT Display Driver Installation for AP2 Module ECT Display Driver Installation for AP2 Module Overview The ECT Display Driver is a small module with a removable wire harness that mounts behind the driver's foot well cover. All wiring connections are

More information

Computerscales DX Model Operating Instructions

Computerscales DX Model Operating Instructions 16892 146 th St SE, Monroe, WA 98272 (360) 453-2030 Computerscales DX Model 72641 Operating Instructions QUICK START INSTRUCTIONS: 1) Set up pads alongside kart (they are interchangeable). 2) Connect cables

More information

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual RD712 & RD712XL Remote Displays Model 615 / 615XL Indicator User s Manual EUROPEAN COUNTRIES WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which

More information

Operating Instructions Precision balance

Operating Instructions Precision balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Instructions Precision balance KERN Version

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Canadian Manufacturer of Quality Weighing Systems

Canadian Manufacturer of Quality Weighing Systems Sept., 2005 Product Update Thank you for purchasing your load beam scale system from Massload Technologies. We genuinely hope that this system will provide years of trouble free operation in your application

More information

Instruction Manual Pallet Truck with Load Indicator

Instruction Manual Pallet Truck with Load Indicator Instruction Manual Pallet Truck with Load Indicator Note: Owner/Operator must read and understand this instruction manual before using the pallet truck with scale. Thank you for using this hand pallet

More information

uline.com

uline.com π H-1679 H-2331 PALLET TRUCK SCALE 1-800-295-5510 uline.com Avoid placing the scale in locations that may AFFECT accuracy: 1. Temperature extremes Do not place in direct sunlight or near air conditioning

More information

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS CONTENTS SAC SERIES TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE 1. INSTALLATION 2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS OPERATION

More information

OVERVIEW OF CONTROLS

OVERVIEW OF CONTROLS π H-5819, H-5820 H-5821, H-5822 DELUXE COUNTING SCALE 1-800-295-5510 uline.com OVERVIEW OF CONTROLS DISPLAY DEFINITIONS # NAME DESCRIPTION 1 DISPLAY 2 1 3 STABLE 4 RECHARGE PAGE 1 OF 8 Displays the total

More information

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2. American Weigh Scales LS-110 User Manual LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 LS-110 Manual Thank you for purchasing the American Weigh LS-110

More information

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions THUNDERBIRD Agricultural Weighing Systems SS1000 Instructions Installation Locate a weighing site that is well drained. For best weighing results, ensure the weigh bars and weighing platform are on a level

More information

Envirotainer RAP e2 Container Operations Manual

Envirotainer RAP e2 Container Operations Manual Operations Manual This manual is valid for: RAP container, P/N 140010R-() Version 1.5: 2016-04-15 www.envirotainer.com Operations Manual RECORD OF REVISION RECORD OF REVISION VER. NO. ISSUE DATE REVISION

More information

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components T29 series Wash Down S cale Technical Manual TotalcompR Scales & Components T29 Series Technical Manual Manufacturer Model Report No Applicable Standards Totalcomp Inc. T29 ASZ091201012S-2 IP65 Totalcomp

More information

Operating instructions Platform/floor scales

Operating instructions Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN

More information

Installation & Calibration Manual

Installation & Calibration Manual Installation & Calibration Manual SkidWeigh ED2-Print Series On-board Lift Truck Check Weighing Scale With Accumulative Load Total ED2-Print V1600 General Installation Guide This SkidWeigh ED2-Print system

More information

WESCO INDUSTRIAL PRODUCTS, INC. Scale Pallet Truck. Part Number: &

WESCO INDUSTRIAL PRODUCTS, INC. Scale Pallet Truck. Part Number: & WESCO INDUSTRIAL PRODUCTS, INC Scale Pallet Truck Part Number: 272936 & 272938 Note: Operator MUST read and understand these operating instructions before using this Hand Pallet Truck. Page 1 of 16 TABLE

More information

Computerscales DX Model Operating Instructions (Also applies to models 72632, 72635, 72636)

Computerscales DX Model Operating Instructions (Also applies to models 72632, 72635, 72636) 16892 146 th St SE, Monroe, WA 98272 (360) 453-2030 Computerscales DX Model 72634 Operating Instructions (Also applies to models 72632, 72635, 72636) QUICK START INSTRUCTIONS: 1) Set up pads alongside

More information

Top quality For industrial use

Top quality For industrial use HAND PALLET TRUCK SCALES RAVAS-110 Pallet truck scale with basic scale functions BENEFITS: The RAVAS work horse All basic scale functions Competitive pricing Low power consumption For checking incoming

More information

4 B High Do not allow anyone except the signal person in the working area

4 B High Do not allow anyone except the signal person in the working area LOADING OPERATIONS Always operate the mast and forks from the operator's seat Be careful not to operate the lever by mistake. There is danger that the forks or work equipment may cause serious injury Unauthorised

More information

DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL

DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL DIGITAL CRANE SCALE USER MANUAL MODEL: OCS-S9 USER MANUAL ERT01.013 SSE TABLE OF CONTENTS SAFE OPERATION GUIDE--------------------------------------------------------------------------------2 CHAPTER 1

More information

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL Models XTCII ECONOMY COUNTING SCALE www.mt.com/xpress 2 ECONOMY COUNTING SCALE ABOUT THIS MANUAL AND MT EXPRESS Thank you for purchasing an MT Xpress product.

More information

Electronic Crane Scale

Electronic Crane Scale Electronic Crane Scale 1 NATA Calibration available on request 2 IMPORTANT Thank you for choosing a Nobles RIG-MATE crane scale. To ensure a long and trouble free service life please read this manual carefully

More information

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION 0 8100, 9100, 9600, 9610, 9615, 9640, No errors 9650, 9700, 9710, 9705, 9750, RL5000 (SDD),RL5000 (TDM), RT2000, 9800, MAKO, SuperScrip 1 9615 Unsolicited note channel 1 2 9615 Unsolicited note channel

More information

Installation & Calibration

Installation & Calibration Installation & Calibration ED2E Elite SkidWeigh System Lift Truck On-board Weighing Scale ED2-Elite V1.0 General Installation Guide This ED2-Elite SkidWeigh system installation & calibration guide describes

More information

GRAVITY MEASUREMENT, INC.

GRAVITY MEASUREMENT, INC. COUNTING SCALE User and Service Manual Model: CCT10/CCT20 Please read this manual carefully before operation ----General Precautions ----Operating condition and other attentions ----Warranty GRAVITY MEASUREMENT,

More information

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-02 Installation and Operation Manual Please read carefully before installation Contents Specifications:... 2 1.0 Installation and Set-up Overview... 3 2.0 Gauge Installation

More information

500Z Owner's Manual & Troubleshooting

500Z Owner's Manual & Troubleshooting 500Z Owner's Manual & Troubleshooting Z TROUBLESHOOTING & OPERATION NOTES: Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns

More information

USER MANUAL PT-450. Please take time to read these instructions before starting to use the scale. Version /17

USER MANUAL PT-450. Please take time to read these instructions before starting to use the scale. Version /17 USER MANUAL PT-450 Please take time to read these instructions before starting to use the scale Version 1.0 08/17 Contents Product Specification 3 Safety Instructions 4 Loading & Moving Guidance 5 Before

More information

Operators Guide: RoboSign Stop/Go Traffic Control System

Operators Guide: RoboSign Stop/Go Traffic Control System Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide NZTA Conditions - Automated Stop/Go Traffic Control System NZTA

More information

MDI-20. User Manual. Baby Scale. MDI-20 (44lb x 0.1oz) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

MDI-20. User Manual. Baby Scale. MDI-20 (44lb x 0.1oz) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 Baby Scale User Manual MDI-20 (44lb x 0.1oz) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 Thank you for purchasing the American Weigh MDI-20 baby scale. Please read all operating

More information

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL Blank page Contents Caution... 4 Capabilities... 4 Display and Keypad... 4 Preparations Before the Test... 6 Connecting

More information

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8 CONTENTS SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8 ELECTRICAL PRINCIPLE DIAGRAM...10 DISPLAY MESSAGE...11 TROUBLESHOOTING...12

More information

Quick Guide. brite Advanced Retail scale

Quick Guide. brite Advanced Retail scale Quick Guide brite Advanced Retail scale 2 METTLER TOLEDO Quick Guide brite Advanced Contents 1 Your new retail scale...4 1.1 Safety instructions...4 1.2 Further documents...4 1.3 Maintenance...4 1.4 Intended

More information

Installation and User Manual. with RAIN SENSOR.

Installation and User Manual. with RAIN SENSOR. with RAIN SENSOR www.solarsmartopener.com Revision..0 TABLE OF CONTENTS Features In The Box Further Items Required Basic Operation Solar Panel and Operator Installation Operator Installation Solar Panel

More information

Service Manual Electronic Precision Balances Page 2. KERN CH version 1.0. CH-SH-e-0110

Service Manual Electronic Precision Balances Page 2. KERN CH version 1.0. CH-SH-e-0110 E Service Manual Electronic Precision Balances Page 2 KERN CH version 1.0 CH-SH-e-0110 E KERN CH version 1.0 Service Manual Electronic Precision Balances 1 INTRODUCTION...3 1.1 Features...3 1.2 Simple

More information

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

1. Introduction Specifications Operation Guide Trouble shooting Note... 13 Content 1. Introduction...1 Notice...1 Safety Guide...1 2. Specifications...2 Features...2 Specifications...3 Capacity and Resolution...4 Schematic Diagram...4 Dimension...5 3. Operation Guide...6 Power

More information

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE USER MANUAL TBI 0310 6/2012 TRAUMATIC BRAIN INJURY DEVICE Page 1 of 26 Setting up the TBI 0310 Head Impactor The TBI 0310 Head Impactor when fully assembled has the following components: 1. Control box

More information

Ohaus ES Series Bench Scale

Ohaus ES Series Bench Scale Ohaus ES Series Bench Scale INSTRUCTION MANUAL 1 2 DECLARATION OF CONFORMITY Ohaus Corporation, 19A Chapin Road, P.O. Box 2033, Pine Brook, NJ, 07058, USA We, Ohaus Corporation, declare under our sole

More information

Inlet Controller SB3500 USER'S MANUAL

Inlet Controller SB3500 USER'S MANUAL Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice

More information

Operators Guide: RoboSign Stop/Go Traffic Control System

Operators Guide: RoboSign Stop/Go Traffic Control System Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide Table of Contents Operators Guide: RoboSign Stop/Go Traffic

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

American Weigh Scales, Inc. DigiPEN-500 D i g i t a l H a n g i n g S c a l e. User Manual

American Weigh Scales, Inc. DigiPEN-500 D i g i t a l H a n g i n g S c a l e. User Manual American Weigh Scales, Inc. DigiPEN-500 D i g i t a l H a n g i n g S c a l e User Manual DigiPen-500 Manual Thank you for purchasing the American Weigh DigiPen-500 digital hanging scale. Please read all

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d) CS-250 Series CHAIR SCALE SERVICE MANUAL (v1.06d) CONTENTS 1. PRECAUTIONS..2 2. INTRODUCTION 3 3. SPECIFICATIONS...4 3.1Specifications...4 3.2 Load Cell Specification......5 4. INSTALLATION..6 5. DESCRIPTION...8

More information

9 Locomotive Compensation

9 Locomotive Compensation Part 3 Section 9 Locomotive Compensation August 2008 9 Locomotive Compensation Introduction Traditionally, model locomotives have been built with a rigid chassis. Some builders looking for more realism

More information

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for: GREER COMPANY Page 1 of 22 MicroGuard 586 Retrofit Rated Capacity Indicator System Machine Model Serial Number Tester Date Calibration and Testing for: GREER COMPANY Page 2 of 22 MicroGuard 586 Retrofit

More information

Weighing Scale IDS-802. User Manual

Weighing Scale IDS-802. User Manual Weighing Scale IDS-802 User Manual A. MAIN SPECIFICATION Model: Capacity: Accuracy: Display: IDS-802 Weighing scale 3kgx0.1g,6kgx0.2g,15kgx0.5g,30kgx1g Grade III, n=30,000 Single 6 digits LCD with Blue

More information

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL Battery Management Innovation For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL ! CAUTION Because of the possibility of personal injury, always use extreme caution

More information

Instruction of connection and programming of the VECTOR controller

Instruction of connection and programming of the VECTOR controller Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring

More information

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter Model FMBC3000 Series Operating Instructions Drum Pump Flow Meter Table of Contents Safety... 1 Introduction... 1 Specificatons... 1 Features... 1 Section 1 - Installation... 2 Section 2 - Operation...

More information

Digital Hand Controller. Manual

Digital Hand Controller. Manual Digital Hand Controller Manual Authors: Dr.-Ing. T. Vaupel, D. Richter, M. Berger Translated by Wolfram Steinke Copyright Uhlenbrock Elektronik GmbH, Bottrop 3rd Edition March 2004 All Rights Reserved

More information

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability) MODEL TI-500 RF Series Digital Weight Indicator (with wireless weighing capability) User Manual Revision 1.4 July 6, 2018 Table of Contents OVERVIEW... 3 Scope of TI-500 RF Series... 3 BASIC OPERATION...

More information

EV Display User Guide

EV Display User Guide EV Display User Guide CleanPowerAuto LLC Brief Description: EV Display is designed to track battery state of charge and other related data in battery powered Electric Vehicle. EV Display is primarily designed

More information

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS NGW & HGW SERIES HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE CONTENTS CAUTIONS 1. INSTALLATION 2. SPECIFICATIONS OPERATION MANUAL 3. KEYBOARD LAYOUT AND DESCRIPTION 4. INITIAL SETUP PLEASE READ THIS MANUAL

More information

Quick Guide. Unipro Laptimer Version Go faster faster. UNIPRO ApS

Quick Guide. Unipro Laptimer Version Go faster faster. UNIPRO ApS Quick Guide Unipro Laptimer 5004 Version 1.32 Go faster faster UNIPRO ApS VIBORG HOVEDVEJ 24 DK-7100 VEJLE DENMARK Tel.: +45 75 85 11 82 Fax: +45 75 85 17 82 www.uniprolaptimer.com mail@uniprolaptimer.com

More information

TP Series OWNER S MANUAL. Price Computing Scale (VER.2)

TP Series OWNER S MANUAL. Price Computing Scale (VER.2) Price Computing Scale TP Series (VER.2) OWNER S MANUAL CONTENTS PRECAUTIONS 4 PREFACE 6 NAMES AND FUNCTIONS 6 OPERATIONS 8 1. General Weighing 8 2. Weighing with Tare 9 3. How to Set % 10 4. How to Use

More information

Operator s Manual Portable Wood Chip Moisture Tester ENGLISH

Operator s Manual Portable Wood Chip Moisture Tester ENGLISH Operator s Manual Portable Wood Chip Moisture Tester ENGLISH DOCU-M0137 0212 Introduction THANK YOU for purchasing a Wood Chip Moisture Tester. READ THIS MANUAL carefully to learn how to operate and service

More information

DIGITAL TORQUE GAUGE MODEL BTGE-G

DIGITAL TORQUE GAUGE MODEL BTGE-G DIGITAL TORQUE GAUGE MODEL BTGE-G OPERATING INSTRUCTION BTGE-G BTGE-G Model To use this product properly and safely, please read this manual carefully before use. If you have any question about the product

More information

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-01 Installation and Operation Manual Please read carefully before installation Contents Specifications:... 2 1.0 Installation and Set-up Overview... 3 2.0 Gauge Installation

More information

Hydraulic energy control, conductive part

Hydraulic energy control, conductive part Chapter 2 2 Hydraulic energy control, conductive part Chapter 2 Hydraulic energy control, conductive part To get the hydraulic energy generated by the hydraulic pump to the actuator, cylinder or hydraulic

More information

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013) Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when

More information

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2. American Weigh Scales SG-300 User Manual SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 SG-300 Manual Thank you for purchasing the American Weigh SG-300 spoon

More information

Installation Guide Rollerdor RD55 Econ Roller Garage Door

Installation Guide Rollerdor RD55 Econ Roller Garage Door Installation Guide Rollerdor RD55 Econ Roller Garage Door 1 Finished door Rollerdor RD55 Econ Roller Garage Door CHECKLIST & COMPONENTS EQUIPMENT REQUIRED 2 x Step ladders or hop ups Spirit level Tape

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

DIGITAL CRANE SCALE MODEL: OCS-SP USER MANUAL

DIGITAL CRANE SCALE MODEL: OCS-SP USER MANUAL DIGITAL CRANE SCALE USER MANUAL MODEL: OCS-SP USER MANUAL TABLE OF CONTENTS SAFE OPERATION GUIDE......... 2 CHAPTER 1 FEATURES AND SPECIFICATION... 3 1. Features...3 2. Main technical data...3 3. Specification......4

More information

Instructions Manual Control Unit RCU205

Instructions Manual Control Unit RCU205 Instructions Manual Control Unit RCU205 1 / 8 Instructions Manual 2 / 8 1. Introduction RCU 205 RCU device main field application is the load limitation in elevators. The measurement accuracy is higher

More information

Manual KREBS Viscometer PCE-RVI 5

Manual KREBS Viscometer PCE-RVI 5 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

MicroGuard 510 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

MicroGuard 510 Retrofit Rated Capacity Indicator System. Calibration and Testing for: Greer Company Page 1 of 27 MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration and Testing for: Machine Model Serial Number Tester Date Greer Company Page 2 of 27 Notice This document and

More information

CONTENTS 1 V400 SERVICE MANUAL. 1.0 Vulcan On-Board Scale System... 5

CONTENTS 1 V400 SERVICE MANUAL. 1.0 Vulcan On-Board Scale System... 5 CONTENTS 1 V400 SERVICE MANUAL Table of Contents 1.0 Vulcan On-Board Scale System...................... 5 1.1 Load Cells............................................. 6 1.2 Vulcoders..............................................

More information

UP100AC INSTRUCTION MANUAL

UP100AC INSTRUCTION MANUAL UP100AC AC/DC Charger INSTRUCTION MANUAL 100W 10A TABLE OF CONTENTS Introduction... 2 Special Features... 4 Warning and Safety Notes... 6 Lithium Battery Connection Diagram... 10 Operation Diagram - Homepage...

More information

Operating manual Platform/floor scales

Operating manual Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating manual Platform/floor scales KERN / / EOS Type _B Type _B Type EOS_B Version 4.1 2017-04 GB Phone: +49-[0]7433-9933-0 Fax:

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72 BT D-01 1 2 USER GUIDE GB Digital Thermostat 4-25 GUIDE D UTILISATION F Thermostat digital 26-49 Bedienungsanleitung D Termostato digital 50-72 GUÍA DE USUARIO ES Termostato digital 74-97 GUIA DO UTILIZADOR

More information

OPERATOR'S MANUAL AND MAINTENANCE INFORMATION MODEL T-2000 TEXTURE TEST SYSTEM

OPERATOR'S MANUAL AND MAINTENANCE INFORMATION MODEL T-2000 TEXTURE TEST SYSTEM OPERATOR'S MANUAL AND MAINTENANCE INFORMATION MODEL T-2000 TEXTURE TEST SYSTEM This Publication contains information proprietary To Food Technology Corporation The contents of this publication may not

More information

PowerLink JC Series Torque Transducer User Manual

PowerLink JC Series Torque Transducer User Manual PowerLink JC Series Torque Transducer User Manual XiangYi (Hong Kong) Power Testing Instrument Co. Ltd. 0 JC Series Torque Transducer User Manual How to install the sensor properly JC-type torque transmission

More information

Service Manual Model S800 Smart Stand

Service Manual Model S800 Smart Stand Service Manual Model S800 Smart Stand Form #1-146 Rev. 10/3/13 Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 7 Smart Stand Operating Instructions 9 Scale Calibration 10 Advanced Smart

More information

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011-

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011- Proceedings of ASME PVP2011 2011 ASME Pressure Vessel and Piping Conference Proceedings of the ASME 2011 Pressure Vessels July 17-21, & Piping 2011, Division Baltimore, Conference Maryland PVP2011 July

More information

User Manual. Aarhus University School of Engineering. Windtunnel Balance

User Manual. Aarhus University School of Engineering. Windtunnel Balance Aarhus University School of Engineering Windtunnel Balance User Manual Author: Christian Elkjær-Holm Jens Brix Christensen Jesper Borchsenius Seegert Mikkel Kiilerich Østerlund Tor Dam Eskildsen Supervisor:

More information

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview

More information

Service Manual Model S400 and S500 Smart Stand

Service Manual Model S400 and S500 Smart Stand Service Manual Model S400 and S500 Smart Stand Form #1-145 Rev. 10/3/13 Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 7 Smart Stand Operating Instructions 9 Scale Calibration 10 Advanced

More information

Rotary Inclinometer. User Manual: (Draft Version)

Rotary Inclinometer. User Manual: (Draft Version) TomTom-Tools GmbH Phone 1: +41 79 774 06 42 Wiesenstrasse 15 Phone 2: +41 79 774 06 44 5400 Baden Info@tomtom-tools.com Switzerland www.tomtom-tools.com User Manual: (Draft Version) Rotary Inclinometer

More information

HYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS

HYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS HYDRAULIC PALLET TRUCK MODEL No: PTE550 PART Nos 7630171 OPERATION & MAINTENANCE INSTRUCTIONS 0604 Please read these instructions carefully before operating the truck Thank you for purchasing this CLARKE

More information

Table of Contents. Chapter 1 Product Summary... 2

Table of Contents. Chapter 1 Product Summary... 2 Table of Contents Chapter 1 Product Summary... 2 1.1 Product Profile... 2 1.2 Product Function... 2 1.3 Technical Parameters... 2 1.4 Working Environment Requirement... 3 Chapter 2 Tester Structure...

More information

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale KILOTECH KWD 500 Water tight Portion/Weighing Scale Operation Manual Version 1.0 Last Modified: Jan 2006 1 Industrial Weighing Systems 9 Richmond St. Picton, ON Canada K0K 2T0 Ph: 613-786-0016 Cell: 613-921-0397

More information

Service Manual Model L1000 Smart Lift

Service Manual Model L1000 Smart Lift Service Manual Model L1000 Smart Lift Form #1-147 Rev. 10/1/13 Table of Contents Parts Breakdown 3 Monthly Maintenance Checklist 5 Smart Lift Operating Instructions 7 Scale Calibration 8 Advanced Smart

More information