1 GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS FOR SELECTIVE LEVEL METER GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 1 of 9
2 (A) SPECIAL INSTRUCTIONS TO BIDDER Please read following instructions carefully before submitting your bid. 1. All the drawings, i.e. elevation, side view, plan, cross sectional view etc., in AutoCAD format and manuals in PDF format, for offered item shall be submitted. Also the hard copies as per specification shall be submitted. 2. The bidder shall submit Quality Assurance Plan for manufacturing process and Field Quality Plan with the technical bid. 3. The bidder shall have to submit all the required type test reports for the offered item. In case of non-submission of the type test reports with the offer, the bid shall be liable to be rejected. 4. The bidder must fill up all the point of GTP for offered item/s. Instead of indicating refer drawing, or as per IS/IEC, the exact value/s must be filled in. 5. All the points other than GTP, which are asked to confirm in technical specifications must be submitted separately with the bid. 6. Please note that the evaluation will be carried out on the strength of content of bid only. No further correspondence will be made. 8. The bidder shall bring out all the technical deviation/s only at the specified annexure. 9. The bidder should indicate manufacturing capacity by submitting latest updated certificate of a Chartered Engineer (CE). GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 2 of 9
3 PREQUALIFICATION REQUIREMENTS : 1. The bidder shall be Original Equipment Manufacturer or authorized dealer/supplier of manufacturing firm for Selective Level Meter offered. The offered equipments should have been designed, manufactured and tested as per relevant IS/IEC Standards with latest amendments. The dealer/supplier shall have to submit valid Authorization letter of manufacturer for the offered equipment along with the bid in Manufacturer s Authorization Form of Annexure-I attached. 2. The bidder should indicate manufacturing capacity & no. of units manufactured for manufactured firm during last 5 years & supplied during last 3 years for offered Selective Level Meter by submitting fresh certificate of a Chartered Accountant (CA) Or Chartered Engineer (CE). 3. The bidder should clearly indicate the quantity and single value contract executed during last FIVE (5) years, for the offered equipment. The details of past supplies should cover, i) Same rated equipment as Offered supplied to other Utilities with Performance certificate. 4. The bidder shall furnish the copies of test reports of international /NABL accredited laboratory for offered measuring instrument. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 3 of 9
4 PREAMBLE:- The G.E.T.C.O. has established network of PLCC Communication. The PLCC network covers various 400KV, 220KV, 132KV and Power Stations for speech, data & protection. PLCC communication operates within frequency range of 50 khz-500 khz. For maintenance of PLCC link, measurement of various frequency level is necessary from AF level to 600 khz. REQUIREMENT:- 1. The Selective Level Meter shall measure frequency level from 50Hz to 620 khz and 200 Hz to 620 khz unbalanced and balanced inputs respectively. 2. The SLM shall have wide input range -70dB to 30dB with unbalanced input and -60dB to 40dB with balanced input. 3. The SLM shall be suitable for wideband as well as selective Measurement facility with selection arrangement. 4. The measurement of frequency level without selectable band shall be continuously starting from 200Hz to 620 KHz and shall have frequency setting both coarse and fine. 5. The SLM shall be equipped with 7 segments LCD display of minimum 6 digits. 128 X 64 Graphic LCD with Backlit. 6. The SLM shall have built in battery charger for charging of internal battery & shall display battery capacity. 7. SLM shall be suitable for measurement of cross talks and interference signals of low level. 8. SLM shall have synchronisation facility for easy selective measurement i.e. automatic tracking between level meter and generator. 9. SLM shall have selectable input impedance with terminated input impedance of 75 Ω, 125 Ω, 150 Ω, 600 Ω. 10. It shall have measuring range in steps of 10 db switchable for 0 db meter reading. 11. The resolution of measured level shall be less than 0.01dB with 5- digit display & frequency resolution shall be with 6-digit display up to (1Hz to 100 KHz curser settable). 12. It will be added feature if display shows separately carrier frequency and channel frequency; the channel frequency can be tuned for that display and shall show the level of that channel frequency for both upper and lower 4 KHz band. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 4 of 9
5 13. The sensitivity of SLM for Selective Measurement in the step of 10 db shall be of the order of 90 to + 40 dbm & - 70 to + 40 dbm input for 20 Hz & 3.1 KHz Bandwidth respectively. The SLM sensitivity for wideband Measurement in steps of 10 db shall be of the order of 60 to + 40 db / dbm and 70 to + 30 db / dbm balance & unbalanced input respectively. 14. The Level measurement error for frequency range 200Hz to 620 KHz shall be < db for both selective and wideband measurement. 15. The display accuracy shall be of the order of digit & frequency stability 10PPm/ C. 16. The SLM shall work satisfactory in the temperature range of 0 to 50 centigrade. 17. The SLM shall work satisfactory in the 85% humidity noncondensing. 18. The SLM shall work continuously without affecting the performance of measurement. 19. The SLM shall operate on single-phase 230V +/- 15% AC supply of 50Hz + 2.5Hz frequency and shall operate on external and internal DC battery supply and shall have provision to operate on dry battery cell. 20. The impedance & return loss measurement shall be measured either by appropriate attachment of directly by SLM. But with arrangement of attachment the SLM shall have to give return loss measurement reading directly on display for frequency under measure. 21. The Image frequency rejection shall be greater than 70 db. 22. The SLM shall also require to measure the RTU signal level. This signal level would require to be shown when RTU of sub-station transmit signal routed through PLCC Link. Hence SLM should require having facility to display the reading at that particular moment or should have to store the reading which could be seen after measurement. 23. The SLM shall have internal calibration facility. It shall have auto calibration & will calibrate the SLM after switching ON A.C. supply & also just by one time finger towards operation as and when required. 24. The SLM shall have Digital Synthesized local oscillator. 25. The SLM shall have facility for storage of spot frequencies (Minimum 15 Nos. of frequencies in memory). 26. The SLM shall go on power saving mode whenever operating on battery to save the battery. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 5 of 9
6 THE SCOPE: - The following shall be in the scope of the supply. 1. Selective Level Meter 1 No. Each with following accessories Core Power supply cord: 1 No Pin to 3 Pin Cable: 1 No. 4. BNC to BNC Cable: 1 No. 5. Unbalanced / Balance measuring cables. BNC to 2 pin crocodile type cable and 3 pin to crocodile pin with minimum 2 meter length. 6. Instructions Manual. 7. Service Manual. 8. Rechargeable batteries with minimum memory effect. 9. Battery connecting cable for external battery. 10. Return loss & composit loss measurement attachment which shall have design such that return loss / composite loss can be readable display from SLM without any further calculation. 11. Carrying Case : 1 No. THE BIDDERS: 1. The bidders shall be manufacturer or authorise supplier /dealer of the manufacturing firm. 2. The bidders shall give the details of collaboration/technology used. 3. The bidders shall give the full technical details and write-up for the product offered. 4. The bidders shall give the details of manufacturer for the bought out items if any. 5. The bidders shall explain in details the features of the equipment offered. 6. The bidders shall clearly indicate the deviation and limitation if any. 7. The bidders shall demonstrate the actual working of SLM at Gotri office after opening of the Technical bid. 8. The bidders shall give the full details of order executed for supply of equipment offered. 9. The bidders shall have to give the details of the after sales service offered. 10. The bidders should have supplied the offered equipment to any Government organisation and should have work satisfactorily for atleast 5 years. 11. The bidders shall clearly indicate the optional item/charges offered. 12. Warranty 3 Years (1) 2 Year at Site. (2) 1 Year at works. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 6 of 9
7 GUARANTEED TECHNICAL PARTICULARS (A) GENERAL 1. Manufactured by 2. Model/Type (B) Input frequency 1. Balanced 2. Unbalanced. 3. Storage Facility (C) Input impedance. 1. Terminated Input in Ohms 2. Unterminated balanced input in K Ohm 3. Unterminated unbalanced input in K Ohm 4. Balanced of in put in db (D) Wideband Level Measurement. 1. Frequency Range in KHz. 2. Sensitivity - With Balance Input in db. - Unbalance Input in db. 3. Lowest reading approximately in db. 4. Level Measurement error. 5. Frequency response for Wide band. (E) Selective Measurement. 1. Frequency Range in khz. 2. Frequency Setting. 3. Lowest reading approximately in db. 4. Resolution. a) Level b) Frequency 5. Level Measurement error. 6. Frequency stability in PPM / ºC. 7. Image frequency Rejection. 8. Sensitivity in db. 9. Frequency response. (F) Frequency Display. 1. Type of Display. 2. No. of Digits. 3. Frequency accuracy. (G) Supply. 1. AC mains 2. DC Battery. 3. Consumption: AC in Amp. DC in Amp. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 7 of 9
8 (H) Atmospheric Condition. 1. Operating Temperature. 2. Operating humidity. 3. Operating Time. (I) Balanced and return loss. 1. Frequency Range. 2. Impedance limit. 3. Maximum balance or return loss to be measured. 4. Accuracy. (J) Impedance Measurement. 1. Frequency Range. 2. Measuring Range. 3. Accuracy. (K) Dimensions W x H x D in mm (L) Weight Kg. GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 8 of 9
9 Annexure-I (On Original Letter Head of Manufacturing Company) Manufacturer's Authorization Form Date: To, The Chief Engineer (Project) Gujarat Energy transmission Corporation Ltd, Sardar patel Vidyut Bhavan, Racecourse, Vadodara (Gujarat) India Dear Sir, Sub : Manufacturer s Authorization Letter Ref. No : Tender No. (Tender No to be mentioned) We M/s (Manufacturing Firm Name to be mentioned) who are official manufacturer of (Product Model Name /Number to be mentioned) having factories at (Manufacturing Unit Address to be mentioned) do hereby authorize M/s (Authorized Party Name and Address to be mentioned) to submit a bid, and sign the contract with you for the supply of Materials / equipment manufactured by us against the tender specification of tender No. (Tender No to be mentioned) No company or firm or individual other than (Authorized Party Name to be mentioned) are authorized to bid, and conclude the contract in regard to this business against this specific tender no: (Tender No to be mentioned) We hereby undertake responsibilities and extend our support during warranty period and thereafter sales service support for ( equipment Model Name / Number to be mentioned) quoted and offered by the above firm against tender no: (Tender No to be mentioned). We also agree to bind with all the terms & condition of tender no: (Tender No to be mentioned) Thanking you, Yours faithfully, For (Manufacturer Name) (Person Name) (Designation) Seal & Sign of Manufacturer Place: GETCO/E/TS- PACC SLM 03504/R0, Dt: Page 9 of 9
SPECIFICATIONS FOR 50 V, 600 AH LEAD ACID BATTERY
(I) INTRODUCTION: Power Line Carrier Communication (PLCC) System is being used by Gujarat Energy Transmission Corporation Ltd. for Speech, Data, Protection and Teleprinter signal transmission purpose throughout
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY SETS
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY
More informationTECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE GETCO/E/TS
More informationINVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09
INVITATION FOR QUOTATION TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 02-Dec-2015 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for
More informationTECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK
TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers
More informationTECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-AL 59 CONDUCTOR FOR 220 KV TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-AL 59 CONDUCTOR FOR 220 KV TRANSMISSION LINE GETCO/E/TS
More informationSPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /
SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / 2005-06 SR.NO ITEM PAGE 1. SCOPE 2 2. WEATHER CONDITIONS 2 3. RATED VOLTAGE & FREQUENCY 2 4. GENERAL REQUIREMENT
More informationTECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH
TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:
More informationTECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES ACSR MOOSE CONDUCTOR FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES ACSR MOOSE CONDUCTOR FOR TRANSMISSION LINE GETCO/E/TS
More informationD.C. DISTRIBUTION BOARD
PRAMBL: The TC is maintaining 50-volt battery backup system for the PLCC communication. The 50-volt D.C. supply from the Float cum Boost charger is brought to D.C. Distribution Board from where supply
More informationFLOAT CHARGER & BOOST CHARGER F O R NO BREAK POWER SUPPLY SYSTEM (Float 100A & Boost 60 A with SCADA application)
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR FLOAT CHARGER (100A) & BOOST CHARGER (60A) FOR WITH REQUIREMENT FOR SCADA
More informationTECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE GETCO/ENGG/TECH.
More informationFLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR NO BREAK POWER SUPPLY SYSTEM WITH REQUIREMENT FOR SCADA
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR GETCO/E/TS-50V BCHR(SCADA)
More information66 kv SF6 CIRCUIT BREAKER (SPRING OPERATED)
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATION FOR 66 kv SF6 CIRCUIT BREAKER (SPRING OPERATED) GETCO/E/06TS CB/R3 May12 Page
More informationTECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES TWIN AL59 CONDUCTOR FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES TWIN AL59 CONDUCTOR FOR TRANSMISSION LINE GETCO/E/TS
More informationTECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES ACSR MOOSE CONDUCTOR FOR 400 KV TRANSMISSION LINE WITH QUAD ACSR MOOSE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES ACSR MOOSE CONDUCTOR FOR 400 KV TRANSMISSION LINE
More informationINVITATION FOR QUOTATION. TEQIP-III/2017/uiet/Shopping/35
INVITATION FOR QUOTATION TEQIP-III/2017/uiet/Shopping/35 09-Jan-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS FOR 220 V BATTERY CHARGER
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 220 V BATTERY CHARGER GETCO / E / TS- BCHR 3202 / R2 Oct 15 Seal & Sign
More informationSECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES
Tamil Nadu Transmission Corporation Limited Bharat Heavy Electricals Limited 400/110 KV Substation at Thappagundu & 400/230-110 KV Substation at Anikadavu, Technical specification for 420/245/132kV Isolators
More informationDakshin Gujarat Vij Company Limited
Dakshin Gujarat Vij Company Limited CIN U40102GJ2003SGCO42909 Regd. & Corporate Office: Urja Sadan, Nana Varachha Road, Kapodara Char Rasta,Surat 395 006 C & R DEPARTMENT Phone No.: 0261 2506100-200-175
More informationTECHNICAL BID T 3627
TECHNICAL BID T 3627 Supply of Mechanical Measuring Instruments for TMD-II OF UKAI TPS. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50
INVITATION FOR QUOTATION TEQIP-III/2018/gcej/Shopping/50 15-Sep-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48
INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/48 29-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationSPECIFICATIONS OF REWIRABLE KIT KAT FUSES
SPECIFICATIONS OF REWIRABLE KIT KAT FUSES 1. SCOPE: This application cover the manufacture, testing at works and supply of porcelain rewire able kit kat fuses suitable for AC 3 phase 415 V 50 HZ solidly
More informationii) PC based works station with monitor and printer having below mentioned specifications:
GAS CHROMATOGRAPH ANNEXURE-A Gas with TCD,FID & Methanizer as below for NFL Bhatinda, Panipat & Nangal Unit (one each): i)gas customized & factory fitted capable of concurrent (parallel) operations of
More informationTHE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT
THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore -452003 (M.P.) ANNEXURE -III REQUIREMENT OICL intends to procure reputed brand Exide or Amara Raja or
More informationTECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:
TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators: (1) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in
More informationREQUEST FOR QUOTATION
REQUEST FOR QUOTATION TO, GAIL WEBSITE VENDOR India Vendor Code - 101019938 RFQ No.: GAIL/08/RJ19140/3300025749/ Dated : 23.07.2008 Kind Attn : Mr/Ms Dear Sir/Madam, GAIL (India) Ltd. invites you to submit
More informationTECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES :
TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES : 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR
GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66
More informationMAHARASHTRA NATURAL GAS LIMITED
Replies to Queries of the Bidders Date: 15.09.2018 SUB: Replies to queries of the bidders against Tender for Procurement of Natural Gas RPD & Turbine Meters with EVC for CGD Network of MNGL, Pune REF:
More informationTECHNICAL BID T 3610
TECHNICAL BID T 3610 Supply of Various Rubber Items at GSECL TPS Ukai. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly Notarized : YES
More informationNLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX
NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX Dr. Rajendra Prasad Road,Block-27,Neyveli-607807.Tamilnadu,India.
More informationTITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record
Page 1 of 10 TABLE OF CONTENTS 0.1 Circulation List 0.2 Amendment Record FOREWORD 1. SCOPE 2. REFERENCES 3. TERMS AND DEFINITIONS 4. REQUIREMENTS 5. TESTS AND INSPECTION 6. MARKING AND PACKING 7. DEMONSTRATION
More informationINDIAN MARITIME UNIVERSITY KOLKATA CAMPUS
INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS No. IMU-KC/Laboratory Equipment/16-17 Date: 17.02.2017 Sub: Quotation for procurement of Instruments for Electrical Machine Laboratory at IMU-Kolkata Campus Sealed
More informationDETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)
DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED (A Govt of West Bengal Enterprise) CHIEF ENGINEER (PROCUREMENT), VIDYUT BHAVAN NOTICE INVITING TENDERS For CONSTRUCTION
More informationSection V DC Nickel Cadmium Alkaline BATTERY
Section - 7 TECHNICAL SPECIFICATION OF 110V DC Nickel Cadmium Alkaline BATTERY TECHNICAL SPECIFICATIONS & REQUIREMENTS OF 110V DC Nickel Cadmium Alkaline Battery 7. 1 GENERAL This section of the document
More informationTENDER NO. MGVCL / PP / D2 / 4017/Metal LTDB
200 KVA L.T. DISTRIBUTION BOX WITH ACB DETAILED TECHNICAL SPECIFICATIONS(Metal Made) Specification for 200 KVA L.T. Distribution Boxes with ACBs on outgoing and incoming side: 1. SCOPE: This specification
More informationSTR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B
STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B February 2017 STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B DRAFT FINAL DRAFT CONTRACT
More informationSection VI: List of Requirements (REVISED)
As per Technical Specifications attached in Section VII Date: 18/06/2018 of Electrical Items With reference to the above tender, the following Corrigendum may kindly be noted against the Section VI, Section
More informationTECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:
TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break
More information/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated:
प रस र भ रत / PRASAR BHARATI (भ रत य ल क स व प रस रक / INDIA S PUBLIC SERVICE BROADCASTER) द रदर शन क न द र / DOORDARSHAN KENDRA ह दर ब द / HYDERABAD 500 013.. Email : sgeddh@yahoo.com / sgeddh@gmail.com
More informationTECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY.
TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY. 1.0 SCOPE: This specification covers the design, manufacturing and testing of LT Distribution
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationTECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE
TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE The hardware fittings suitable for tension string to be used for 11KV consisting of following
More informationTo Date: 23/03/2017. Respective Bidders,
To Date: 23/03/2017 Respective Bidders, Sub: Up-gradation, Operation and Maintenance of Street Lights in Navi Mumbai in Lieu of Rights of Sharing Energy Savings and Advertisement Rights on Public-Private-Partnership
More informationTechnical Specifications
LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for
More informationREQUEST FOR PROPOSAL
Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF PIPES, FITTINGS AND FLANGES TO PALABORA COPPER TENDER NUMBER: RFP.PC.2015/144 PART 1 PROPOSAL INFORMATION AND CONDITIONS Page 1 Supply and Delivery
More informationRef:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013
Ref:CL/Mech./ Cal /BID-0(3-4) Date: 0 July 203 SUBJECT: Procurement of Calibration Services for the Equipments in Central Laboratory (Mechanical). Dear Sirs, Technical & Commercial Bids are invited for
More informationSupply of Batteries
Supply of Batteries 207-8 SUPPLY OF BATTERIES OF VARIOUS RATINGS E-PROCUREMENT (REVERSE AUCTION) NIT No: 07/ 207-8 Name of the work Supply of Batteries to our Branches / Offices /ATM Completion Time EMD
More informationS.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not
S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not clear.please provide Specification for High ampacity HT Cable with Trapezoidal wire
More informationSPECIFICATIONS FOR MOTOR OPERATED VALVES
Doc No: 254625-300-SP-INT-004 Rev: B Page 1 of 11 SPECIFICATIONS FOR MOTOR OPERATED VALVES Hindustan Petroleum Corporation Ltd Visakha Dispatch Station VR-ATP Area, Naval Base Post Visakhapatnam - 530
More informationMGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-
MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:- 01) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution
More informationAppendix I 1. Name of the Agency: HANDLOOM EXPORT PROMOTION COUNCIL TECHNICAL BID 2. Address: 3. Name of the authorised person 4. Telephone No: Office: Mobile: Residence: Fax: 5. Documents to be enclosed:
More informationSPECIFICATIONS OF Ni-Cd BATTERY BANK
SPECIFICATIONS OF Ni-Cd BATTERY BANK ANNEXURE-Z Supply, Installation and commissioning of Ni-cd battery bank for high rate of discharge type KPH 125V 210 AH consisting of 103 number of cells. Detail technical
More informationPalabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS
Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS THIS CONTRACTS IS FOR BIDDERS THAT ARE MORE THAN 26% BLACK
More informationINDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING
To, Ref No: IIT/ EE/SMART CITY/INVERTER AND BATTERY SET/2015/02 INVITATION FOR QUOTATIONS FOR SUPPLY OF THE FOLLOWING ITEMS REQUIRED FOR SMART CITY PILOT PROJECT AT IIT KANPUR S.No. Brief Description of
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/mmug/Shopping/29 To,
INVITATION FOR QUOTATION TEQIP-III/2018/mmug/Shopping/29 To, 04-July-2018 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationGuaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors
Section II - Technical Specification Tender Enquiry No: BUY/EATD(BEE)-01/12-13 Name of the Equipment: MOTOR TESTING SYSTEM Note: The Offers should be submitted only in this format otherwise the offer will
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationSAVE ENERGY FOR BENEFIT OF SELF AND NATION
Taluka: Thasra Dist : Kheda Pin: 388 239 Telephone No. 02699-235 522 Fax No. 02699-235 607 CHIEF ENGINEER (C&O), GSECL,, INVITES TENDERS FROM INTERESTED BIDDERS, FOR SUPPLY OF ABOVE MATERIAL. THE DETAILS
More informationTENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm
TENDER Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm On behalf of INDIAN INSTITUTE OF INFORMATION TECHNOLOGY & MANAGEMENT KERALA (IIITMK), the Registrar invites offers for supply and laying
More information: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS :
: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS : FOREWORD : Even though 11KV Drop Cut Fuse Cut Outs are widely used for protection / isolation of distribution transformers, their quality
More informationRFP Agricultural Tractors (AG tractor) SCOPE OF THE PROPOSAL
Request for Proposal RFP Agricultural Tractors (AG tractor) 1. Introduction SCOPE OF THE PROPOSAL 1.1 The Ontario Federation of Snowmobile Clubs (OFSC) is accepting proposals for the purchase of Agricultural
More information4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.
SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass
More informationFile No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR
OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR Unique No.* Name of Work Name of Department Tender No.* Complete Mechanical works, Electrical works, Body works,
More informationCity of Hammond Purchasing Department RFP # General Maintenance and Repair Service Contract City Generators
1 City of Hammond Purchasing Department RFP # 15-33 General Maintenance and Repair Service Contract City Generators Proposals Shall Be Received by the Purchasing Department, City of Hammond 310 East Charles
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone: +91 431 257 79 38 Fax : +91 431
More informationADDENDUM 02. To All Bidders:
ADDENDUM 02 Project: 2017 Water Truck Request for Tender Addendum: A-02 Location: 117 7 Avenue SE, Drumheller, Alberta Date: October 11, 2017 To All Bidders: 1. General 1.1. This addendum shall be read
More informationWP2 - CFD Private Network Meter Commissioning, Proving and Calibration Tests
WP2 - CFD Private Network Meter Commissioning, Proving and Calibration Tests EMRS Working Practice Public Version: 2.0 Date: 13 October 2017 Table of Contents Change Amendment Record 3 1. Introduction
More informationTENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR
Cost of the Tender Form - Rs.500/- (Rupees Five Hundred only) Tender Form No.MCI/TENDER DGSET/2018 Tender for DG SET MEDICAL COUNCIL OF INDIA POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI 110 077 Website:
More informationSPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE
SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE The hardware fittings suitable for tension string to be used for 11KV / 22 KV consisting of following components.
More informationTechnical Specification
Section - 7 Technical Specification OF 33KV OUTDOOR DROP OUT FUSE CUT-OUT AND FUSE LINK AND 33KV OUTDOOR TYPE SINGLE PHASE METAL OXIDE (ZNO) GAPLESS LIGHTNING ARRESTER 84 7.1. TECHNICAL SPECIFICATION OF
More informationSolar Energy Corporation of India New Delhi-17
Solar Energy Corporation of India New Delhi-7 : SECI/Cont./SRT-IV-P/7/0/ Date: 6-07-0 Subject: tification of L bidders of different States in Part-A and for price matching by L, L,L.and so on..0 The Request
More informationTECHNICAL BID T
` TECHNICAL BID T - 3878 Subject : Supply of Various Measuring Instruments for TMD-I,UKAI TPS Due on Date : At 3.30 P.M. (if Possible) EMD paid YES / NO EMD Demand Draft No. Date : OR SSI / NSIC Certification
More informationRESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION
MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC 62/24/Add.1 Annex 24, page 1 ANNEX 24 RESOLUTION MEPC.205(62) 2011 GUIDELINES AND SPECIFICATIONS FOR ADD-ON
More informationOrganization for Security and Co-operation in Europe Mission to Georgia
Organization for Security and Co-operation in Europe Mission to Georgia From: OSCE Mission to Georgia No of Page(s): 5 pages OSCE Ref: Subject: 32.2007 (please quote in all correspondence) Sport Equipment
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:
More informationBHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal (AMRITSAR) Enquiry Date:
BHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal 143422 (AMRITSAR) ENQUIRY Phone:+91 1859 223381 (+91 1859 222002, 222036, 222039 Extn 117) Fax :+91 1859 222 061 Email :srk@ivp.bhel.co.in
More informationNLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX
NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX Dr. Rajendra Prasad Road,Block-27,Neyveli-607807.Tamilnadu,India.
More information: Material Description Quantity UOM
Page : 1 / 6 OIL INDIA LIMITED (A Govt. Of India Enterprise) Tel :033 2230 1657, 1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail :oilcalmn@cal2.vsnl.net.in ANNEXURE-I Item No./
More informationTechnical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications ETS12-01-04 Specification ETS12-01-04 Ver 3 Contents 1. Purpose and Scope...
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationTender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02
Tender No:- MTL/PUR/213/Elect/2015-16 (K)/9 Date:-26/10/2016 Type Of Bid Bidding type Bid closing On Bid Opening On EMD : LIMITED TENDER : Single Bid : 18/11/2016 at 14.00 hrs.(ist) : : As per Annexure
More information/ I S S : / S T S I
Agenda Electrical Transformers (Quality Control) Order Obtaining BIS Licence Requirements of Guidelines / IS 1180-1: 1: 2014 / STI Concerns in Getting BIS Licence Experience with BEE Regulations Recommendations
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS FOR
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 11 kv Indoor VCB SWITCHGEAR PANEL/BOARD GETCO / E / TS HTPB 5401 / R0
More informationTECHNICAL SPECIFICATION
SECTION - III TECHNICAL SPECIFICATION OF AB SWITCH & HG FUSE NESCO : TN/ 17427/14.11.11-1 - 1. 33 KV 200 Amp 3 Pole HG Fuse (Horizontal Mounting Type) Quantity 15 Sets Technical Specification 1. SCOPE:
More informationNATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA
Ref. No. ICS/11-12/013/DSTX/TSUN Date: 1 Sep. 2015 Due date: 22 Sep. 2015 Item name: COMBUSTION ANALYSIS SYSTEM 1. Quotations are invited in duplicate for the items shown overleaf (in Annexure I). The
More informationTechnical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch Scope Description of the materials Standards Insulator make
Technical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch 1. Scope:- This specification covers manufacturing, testing and supply of 11KV 200Amp. 50Hz Air Break switches for outdoor installation
More informationTechnical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...
More informationREFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS
TITLE SPECIFICATION FOR POLE- MOUNTED DATE: JUNE 2006 PAGE: 1 OF 17 TABLE OF CONTENTS Page FOREWORD...2 INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DEFINITIONS AND ABBIATIONS...3 4 REQUIREMENTS...3
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/ntst/Shopping/35
INVITATION FOR QUOTATION TEQIP-III/2018/ntst/Shopping/35 29-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationREQUEST FOR QUOTATION (RFQ) REFERENCE: RFQ/KRT/09/004 DATE: 18/01/2009
REQUEST FOR QUOTATION (RFQ) REFERENCE: RFQ/KRT/09/004 DATE: 18/01/2009 Dear Sir / Madam: You are kindly requested to submit your quotation for the following services by 8 February 2009 12:00 hours (local
More informationSPECIFICATIONS OF ITEMS ANNEXURE-1A Sr. No. Item specification Qty. (in nos.) 1 Computer chair with armrest Approximate Size: Width 64 cm Depth 64cm Height 81.0-93.5 cm Seat Height 42-54.5 as Godrej Model
More information(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:
10111. 4711M1 An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY Corrigendum 1
More informationTechnical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)
Ergon Energy Corporation Limited Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear ETS12-01-03 Specification ETS12-01-03 Ver 3 Contents 1. Purpose and Scope...
More informationAMULFED DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY
PURCHASE ENQUIRY Inquiry No : AFD/PUR/PKS/ENQ/FB, Dated: May 18, 2018 Description Qty : Purchase Inquiry for Supply of Forklifts, Battery Operated Hand Pallet trucks & Hand Pallet trucks for AFD & PFP
More informationSupply, testing, installation and commissioning of 5 ky A UPS system as per the following specification:
Supply, testing, installation and commissioning of 5 ky A UPS system as per the following specification: 1 Capacity 5 ky A UPS system with APFC system 2 Input supply Suitable for400±15% Y, 3 phase, 50
More informationSPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi
SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi 682025 Phone: 0484-2333603 Email: sbqelkochi@gmail.com REQUIREMENT OF UPS Systems and Batteries for Quality
More information400 kv SF6 CIRCUIT BREAKERS (with PIR and Spring Spring Mechanism)
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS OF 400 kv SF6 CIRCUIT BREAKERS (with PIR and Spring Spring Mechanism) GETCO/E/4TS
More information