1 WIRES & WIRING CBLES CBLES FZE

2

3 Index 1) Introduction ) CU/PVC Wires 450/750 Volts Round Solid (Class 1) H07V-U ) CU/PVC Wires 450/750 Volts - Round Stranded (Class 2) H07V-R ) CU/PVC Wires 450/750 Volts - Round Flexible (Class 5). H07V-K ) CU/LSZH Wires 450/750 Volts - Round Solid (Class 1) H07Z-U ) CU/LSZH Wires 450/750 Volts - Round Stranded (Class 2) H07Z-R ) CU/LSZH Wires 450/750 Volts - Round Flexible (Class 5) H07Z-K ) CU/PVC/PVC Cables 300/500 Volts - Round Solid H05VV-U ) CU/PVC/PVC Cables 300/500 Volts - Round Stranded H05VV-R ) CU/PVC/PVC Cables 300/500 Volts - Round Flexible H05VV-F & H05V2V2-F ) 380 V NYFF PVC Insulation, Non-Sheathed Flexible Cords ) CU/PVC Parallel 300/300 V Twin Flexible Cords- H03VH-H ) CU/PVC/PVC 300/500 V Flat Cables Without Earth Continuity ) CU/PVC/PVC 300/500 V Flat Cables With Earth Continuity ) Current Ratings Tables ) Current Rating Guidelines...21

4 Introduction Mark Cables FZE is a Cable Manufacturer processing both Copper and luminium Rods as input raw material to produce wire and cable as finished product. We are located in Jebel li Freezone Dubai UE. Mark Cables is privately owned with sister companies in ngola, Rwanda, South frica where the group has interests in Wire & Cable, Steel Forming, Paints, Household plastic products manufacturing. Our partner companies are: Milbridge Holding S (Secursal em ngola) (Steel Forming, Wire & Cable, Paints) Primeplast Lda ngola Plastic Products Manufacturing friprecast Rwanda (Precast Concrete Solutions) Casasteel Pty Ltd South frica Steel Products Trading Company Our team is committed to providing our customers value by fering high levels industry experience, superior customer service, and a large selection quality cables in both copper and aluminium wires, building wires, flexible cables, control cables, low voltage power cables, overhead conductors and underground cables. Vision, Mission & Core Values Our Vision: To be a Leading Quality Manufacturer Cables and Related Products in the Middle East and frica. Our Mission: We are committed to developing and improving manufacturing methods to ensure the highest possible level value, quality and products to meet our clients needs through being a responsible and dependable manufacturer Our Core Values: Our corporate values center on four core elements explained below: Ownership We trust our employees to make every effort to do right by the company, and we make every effort to do right by employees in return Integrity We treasure loyalty, uphold honesty, and practice good business ethics. Reliability We uphold service excellence, take pride in our product quality and ensure commitments are duly fulfilled and are consistently upheld. Teamwork We embrace teamwork, harmony and mutual respect with our customers, suppliers, and employees 02

5 Company Quality Policy Mark Cables FZE is committed to supplying products and services to its clients that fully satisfy their requirements and expectations. Quality permeates our entire process all the way from procurement raw materials, production, quality testing, delivery and after sales backup services to the customer. Our products are manufactured to international standards. Our cables are individually tested in our laboratory to ensure that the products meet the highest standards. Certificates Conformity are available upon request for each shipment. The cables manufactured by Mark Cables FZE are clearly marked with the company name, cable size details and voltage ratings. The management Mark Cables are committed to implementing the following policy:- Customers: Provide products and services that comply with the requirements and expectations our customers. Owners: Provide products that will deliver a prit to the organization without compromise to quality and the necessary resources for Organizational, Operational support management the business. Employees: Provide a safe working environment; develop our team to improve our core competencies and their development and job satisfaction. Suppliers: Select our suppliers and partners fairly and without prejudice to our stakeholders. Community: Engage in charitable works for the benefit our community and society. Statutory/Regulatory Requirements: Comply with applicable legal and statutory requirements 03

6 CU/PVC WIRES 450/750 VOLTS (ROUND SOLID) Copper PVC insulation, BS EN (BS 6004) and IEC H07V-U as per BS EN (BS 6004) Type IEC 01 as per IEC : Round Solid (Class 1) Insulation: PVC Type Tl 1 as per BS EN (BS 6004), Type C as per IEC Based on special request, PVC insulation rated 85ºC and 90 o C (105ºC for reduced duration) can also be provided. For internal wiring equipment rated voltage up to 1000 V C and up to 750 V DC to earth. Cross Section (Solid) Number Wires in Insulation Overall Weight Finished Cable (pprox) DC Resistance at 20ºC mm² mm mm mm Kg / Km Ohm / Km Standard Packing Length 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards Color: green/yellow blue black green red yellow brown grey orange white Packing: 100 Yards in Coils or Spools drums. supplied in km lengths in wooden or steel 04

7 CU/PVC WIRES 450/750 VOLTS (ROUND STRNDED) Copper, PVC insulation, BS EN (BS 6004) and IEC H07V-R as per BS EN (BS 6004), Type IEC 01 as per IEC : Round Stranded (Class 2) Insulation: PVC Type Tl 1 as per BS EN (BS 6004), Type C as per IEC Based on special request, PVC insulation rated 85ºC and 90 o C (105ºC for reduced duration) can also be provided. For internal wiring equipment rated voltage up to 1000 V C and up to 750 V DC to earth. Cross Section (Stranded) Number Wires in Insulation Overall Weight Finished Cable (pprox) DC Resistance at 20ºC Standard Packing Length mm² mm mm mm Kg / Km Ohm / Km 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum 1 x Drum Color: green/yellow blue black green red yellow brown grey orange white wires can also be supplied in km lengths in wooden or steel drums. 05

8 CU/PVC WIRES 450/750 VOLTS (ROUND FLEXIBLE) Copper PVC insulation, BS EN (BS 6004) and IEC H07V K as per BS EN (BS 6004) Type IEC 02 as per IEC : Flexible (Class 5) Insulation: PVC Type TI 1 as per BS EN (BS 6004), Type C as per IEC Based on special request, PVC insulation rated 85ºC and 90 o C (105ºC for reduced duration) can also be provided. For internal wiring equipment rated voltage up to 1000 V C and up to 750 V DC to earth. (Round Flexible) Cross Section Numbers Wires in Insulation Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² No x mm mm mm mm Kg / Km Ohm / Km 1 x x C 1 x x C 1 x 4 50 x C 1 x 6 76 x C 1 x x C 1 x x C 1 x x C 1 x x C 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D Color: green/yellow blue black green red yellow brown grey orange white 06

9 CU/LSZH WIRES 450/750 VOLTS (ROUND SOLID) Copper LSZH Insulation BS EN (BS 7211) H07Z-U as per BS EN (BS 7211) : Round Solid (Class 1) Insulation: Low Smoke Thermosetting Insulation Type EI5 as per BS EN (BS 7211) For internal wiring equipment rated voltage up to 1000 V C and up to 750 DC earth. Cross Section (Solid) Number Wires in Insulation Overall Weight Finished Cable (pprox) DC Resistance at 20ºC Standard Packing Length mm² mm mm mm Kg / Km Ohm / Km 1 x Yards 1 x Yards 1 x Yards 1 x Yards 1 x Yards Color: green/yellow blue black green red yellow brown grey orange white 07

10 CU/LSZH WIRES 450/750 VOLTS (ROUND STRNDED) Copper LSZH Insulation BS EN (BS 7211) H07Z R as per BS EN (BS 7211) : Round Solid (Class 2) Insulation: Low Smoke Thermosetting Insulation Type EI5 as per BS EN (BS 7211) For internal wiring equipment rated voltage up to 1000 V C and up to 750 V DC to earth. Cross Section (Round Stranded) Numbers Wires in. Insulation Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² No mm mm mm Kg / Km Ohm / Km Yards 1 x C 1 x C 1 x C 1 x C 1 x C 1 x C 1 x C 1 x C 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D 1 x D Color: green/yellow blue black green red yellow brown grey orange white 08

11 CU/LSZH WIRES 450/750 VOLTS (ROUND FLEXIBLE) Copper LSZH Insulation BS EN (BS 7211) H07Z K as per BS EN (BS 7211) : Round Flexible (Class5) Insulation: Low Smoke Thermosetting Insulation Type EI5 as per BS EN (BS 7211) For internal wiring equipment rated voltage up to 1000 V C and up to 750 V DC to earth. Cross Section (Round Flexible) Numbers Wires in Insulation Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² No x mm mm mm mm Kg / Km Ohm / Km M ± 5% 1 x x C 1 x x C 1 x 4 50 x C 1 x 6 76 x C 1 x x C 1 x x C 1 x x C 1 x x C 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D 1 x x D Color: green / yellow blue black green red yellow brown grey orange white 09

12 CU/PVC/PVC CBLES 300/500 VOLTS (ROUND SOLID) Copper PVC insulated and PVC Sheathed - IEC H05VV U, IEC TYPE IEC 10 Cross Section Numbers Wires in Insulation Sheath Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² mm mm mm mm Kg / Km Ohm / Km M ± 5% 2 x C 2 x C 2 x C 2 x C 2 x / x C 3 x C 3 x C 3 x C 3 x / x C 4 x C 4 x C 4 x / x / x C 5 x C 5 x C 5 x / x /2000 Colour Insulation: 2 cores: Red, Black 3 cores: Red, Yellow and Blue 4 cores: Red, Yellow, Blue and Black 5 cores: Red, Yellow, Blue, Black and Green Colour Outer sheath Grey. Note: Colour code as per BS Standards shall only be provided based 2 cores: brown and blue 3 cores: green/yellow, blue, brown 4 cores: green/yellow, blue, brown, black 5 cores: green/yellow, blue, brown, black and grey 10

13 CU/PVC/PVC CBLES 300/500 VOLTS (ROUND STRNDED) Copper PVC insulated and PVC Sheathed and IEC H05VV R, IEC TYPE IEC 10 Cross Section Numbers Wires in Insulation Sheath Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² mm mm mm mm Kg / Km Ohm / Km M ± 5% 2 x C 2 x C 2 x C 2 x C 2 x / x / x x x C 3 x C 3 x C 3 x C 3 x / x / x x x C 4 x C 4 x C 4 x / x / x / x x x C 5 x C 5 x C 5 x / x / x / x x Colour Insulation: 2 cores: Red, Black 3 cores: Red, Yellow and Blue 4 cores: Red, Yellow, Blue and Black 5 cores: Red, Yellow, Blue, Black and Green Colour Outer sheath Grey. Note: Colour code as per BS Standards shall only be provided based 2 cores: brown and blue 3 cores: green/yellow, blue, brown 4 cores: green/yellow, blue, brown, black 5 cores: green/yellow, blue, brown, black and grey 11

14 CU/PVC/PVC CBLES 300/500 VOLTS Flexible Copper PVC insulated and Sheathed, BS EN (BS 6500) and IEC H05VV-F, IEC & BS EN (BS 6500) TYPE IEC 53 H05V2V2-F Heat Resistant Cables can be made on special request. Cross Section Numbers & diameter Wires in Insulation Sheath Overall Weight Finished Cable DC Resistance at 20ºC Standard Packing Length mm² no x mm mm mm mm mm Kg / Km Ohm / Km M ± 5% 2 x x x 1 29 x x x x x x 4 50 x x x x 1 29 x x x x x x 4 50 x x x x 1 29 x x x x x x 4 50 x x x x 1 29 x x x x x x 4 50 x Colour Insulation: 2 cores: blue, brown. 3 cores: green/yellow, blue, brown. 4 cores: green/yellow, blue, brown black. 5 cores: green/yellow, blue, brown, black, grey. Colour Outer sheath White. 12

15 PVC INSULTION, NON-SHETHED CORDS FOR INTERNL WIRING Single Core and Twisted Twin COPPER CONDUCTOR: BS EN (BS 6500) and IEC 60227, 300 / 500 VOLTS H05V-K, TYPE IEC 06 Nom. cross sectional area CONDUCTOR Nom. diameter strand Radial insulation Mean overall diameter (upper limit) single DC Resistance at 20ºC pproximate Weight Single mm² mm mm mm Ω / Km Kg / Km Kg / Km Construction: nnealed Copper conductor as per BS EN (BS 6360) or IEC 60228, Class 5 ( Class 1 and Class 2 conductors can be provided based on special request) PVC Insulation Type TI 1 Twin 380 V NYFF PVC INSULTION, NON-SHETHED FLEXIBLE CORDS FOR INTERNL WIRING Single, Three and Four Cross Section Max. Wire in CONDUCTOR Insulation Overall Dimension max DC Resistance at 20ºC Weight Finished Cable mm² mm mm mm mm Ω / Km Kg / Km 1 x x x x x x Construction: nnealed copper conductor PVC Insulation. 13

16 PVC INSULTION, NON-SHETHED FLEXIBLE CORDS FOR INTERNL WIRING PRLLEL TWIN COPPER CONDUCTOR H03VH-H 300/300 VOLTS - IEC Nom. Cross Sectional area CONDUCTOR diameter Wire Radial Insulation Mean overall dimensions Lower Limit Upper Limit DC Resistance at 20ºC Weight Finished Cable mm² mm mm mm mm Ω / Km Kg / Km 2 x x x x x x Construction: nnealed Copper conductor as per BS EN (BS 6360) or IEC Class 6. The conductors shall be laid parallel and covered with PVC insulation. The insulation shall be provided with a groove on each side between the conductors to facilitate separation the cores. 14

17 PVC INSULTED, PVC SHETHED CBLES SINGLE CORE, FLT TWIN ND FLT THREE CORES WITHOUT ERTH CONTINUITY CONDUCTOR COPPER CONDUCTOR STNDRD: BS EN (BS 6004) 300 / 500 VOLTS No. & Cross Sectional area conductor Number Wires in Radial insulation Radial Sheath Mean overall dimensions Lower Limit Upper Limit DC Resistance at 20ºC Weight Finished Cable mm² mm mm mm mm mm Ω / Km Kg / Km 1 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Construction: Plain annealed copper conductor Class 1 or Class 2 as per BS EN (BS 6360). PVC Insulation Type TI 1 PVC Sheath Type 6 The sheath shall be closely but shall not adhere to the cores and in the case twin and three-core the cores shall be laid parallel. Colour Insulation as per BS EN (BS 6004): Single : Brown or Blue Twin : Brown and Blue Three-core: Brown, Black (center), Grey Colour Insulation General Single : Black Twin : Red, Black Three-core: Red, Yellow, Blue Color Sheath: Grey 15

18 PVC INSULTION, PVC SHETHED CBLES, With Earth Continuity, Flat Twin and Flat Three Cores No. & Cross Sectional area conductor Number Wires in Radial insulation Radial Sheath Mean overall dimensions Lower Limit Upper Limit Earth continuity conductor cross section DC Resistance at 20ºC Weight Finished Cable mm² mm mm mm mm mm mm² Ω / Km Kg / Km 2 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Construction: Plain annealed copper conductor Class 1 or Class 2 as per BS EN (BS 6360). PVC Insulation Type TI 1 PVC Sheath Type 6 The sheath shall be closely but shall not adhere to the cores which shall be laid parallel with un-insulated earth continuity conductor. Colour Insulation as per BS EN (BS 6004): Single : Brown or Blue Twin : Brown and Blue Three-core: Brown, Black (center), Grey Colour Insulation General Single : Black Twin : Red, Black Three-core: Red, Yellow, Blue Color Sheath: Grey 16

19 Current Rating CU/PVC Wires TBLE 1 and associated voltage drop for single core PVC insulated cables, non-armoured, with or without sheath CU/PVC 450 / 750 V Wires - BS EN (BS 6004) & BS 6231 operating temperature: 70ºC mbient temperature: 30ºC 2 cables, single-phase a.c. or d.c. Reference Method (enclosed in conduit in the thermally insulating wall etc.) 3 or 4 cables three-phase a.c. 2 cables, single-phase a.c. or d.c. Reference Method B (enclosed in conduit on a wall or in trunking etc.) 3 or 4 cables three-phase a.c. 2 cables, single-phase a.c. or d.c and touching Reference method C (clipped direct) 3 or 4 cables three-phase a.c. and touching or trefoil Reference Method F(in free air or on a perforated cable tray horizontal or vertical 2 cables, single-phase a.c. or d.c. Touching 3 cables, three phase a.c. 3 cables, three phase a.c. trefoil Horiz Space by one diameter 2 cables, single phase a.c. or d.c. or 3 cables three phase a.c. Vert Single phase Three phase C.S mm² a a a a a a a a a a a a a / Where more precise calculation requires the use resistive and reactive components cable impedance, reference should be made to Table 4D1 and 4D1B BS Notes: 1. The current carrying capacities in columns 2 & 4 are also applicable to cables to BS EN (BS 6004) (HO7V-K) where the cables are used in installations. 2. Spacing larger than one cable diameter will result in a larger voltage drop. 3. Cables to BS 6231 when installed in conduit or trunking are rated for 70 ºC Correction Factors For mbient Temperature mbient Temperature 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC Correction Factor

20 Current Rating CU/LSZH Wires TBLE 2 and associated voltage drop for single core XLPE insulated cables, non-armoured, with or without sheath CU/LSZH 450 / 750 V Wires - BS EN (BS 7211) operating temperature: 90ºC mbient temperature: 30ºC Reference Method (enclosed in conduit in thermally insulating wall etc.) Reference Method B (enclosed in conduit on a wall or in trunking etc.) Reference Method C (clipped direct) Reference Method F(in free air or on a perforated cable tray horizontal or vertical Touching Reference Method G (in free air) Space by one diameter 2 cables, single-phase a.c. or d.c. 3 or 4 cables threephase a.c. 2 cables, single-phase a.c. or d.c. 3 or 4 cables threephase a.c. 2 cables, single-phase a.c. or d.c and touching 3 or 4 cables threephase a.c. and touching or trefoil 2 cables, single-phase a.c. or d.c. 3 cables, three phase a.c. 3 cables, three phase a.c. trefoil 2 cables, single phase a.c. or d.c. or 3 cables three phase a.c. C.S.. Horiz Vert Single phase Three phase mm² Where more precise calculation requires the use resistive and reactive components cable impedance, reference should be made to Table 4E1 and 4EIB BS Notes: 1. Where the conductor is to be protected by a semi-enclosed fuse to BS 3036, see item 5.1 the preface to ppendix 4 BS Spacing larger than those in Method C (Table 4) will result in a larger voltage drop. Correction Factors For mbient Temperature mbient Temperature 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC 75ºC 80ºC Correction Factor

21 Current Rating CU/PVC/PVC 300/500 V Cables TBLE 3 for Multicore PVC insulated, PVC sheathed, non-armoured cables as per BS EN (BS 6004) operating temperature: 70ºC mbient temperature: 30ºC For Installation required to comply with BS 7671 Reference Method (enclosed in conduit in the thermally insulating wall etc.) 1 two-core cable, singlephase a.c. or d.c. 1 three-core or 1 four-core cable, threephase a.c. Reference Method B (enclosed in conduit on a wall or in trunking etc.) 1 two-core cable, singlephase a.c. or d.c. 1 three-core or 1 four-core cable, threephase a.c. Reference method C (clipped direct) 1 two-core cable, singlephase a.c. or d.c. 1 three-core cable or 1 fourcore cable, three-phase a.c. Reference method F (in free air or on a perforated cable tray etc, horizontal or vertical) 1 two-core cable, singlephase a.c. or d.c. 1 three-core cable or 1 fourcore cable, three phase a.c. C.S.. Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop Current carrying Voltage drop mm² Where more precise calculation requires the use resistive and reactive components cable impedance, reference should be made to Table 4D2 and 4D2B BS Correction Factors For mbient Temperature mbient Temperature 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC Correction Factor For grouping refer to Table 4C1 BS

22 Current Rating for Flat Cables TBLE 4 and associated voltage drop for thermoplastic (PVC) insulated and Sheathed cable with protective earth continuity conductor for CU/PVC/PVC Cables BS EN (BS 6004) operating temperature: 70ºC mbient temperature: 30ºC For installation required to comply with BS 7671 Reference method 100 ( above a plasterboard ceiling covered by thermal insulation not exceeding 100mm in thickness) Reference method 101 ( above a plasterboard ceiling covered by thermal insulation not exceeding 100mm in thickness) Reference method 102 (in a stud wall with thermal insulation with cable touching the inner surface wall) Reference method 103 (in a stud wall with thermal insulation with cable not touching the inner surface wall) Reference method C (slipped direct) Reference method (enclosed in conduit in an insulated wall) Notes: mm² should be made to Table 4D5 BS 7671 Correction Factors For lternative mbient Temperatures mbient Temperature 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC Correction Factor

23 Current Rating Guidelines Reference Methods as per BS 7671 The Reference Methods are those methods installation for which the current-carrying has been determined by test or calculation. Reference Method, for example, Installation Methods 1 and 2 (non-sheathed cables and multicore cables in conduit in a thermally insulated wall). The wall consists an outer weatherpro skin, thermal insulation and an inner skin wood or wood-like material having a thermal conductance at least 10 W/m².K, but not necessarily touching, the inner skin. Heat from the cables is assumed to escape through the inner skin only. The conduit can be metal or plastic. Reference Method B, for example, Installation Method 4 Table 2 (non-sheathed cables in conduit mounted on a wooden or masonry wall) and installation Method 5 (multicore cable in conduit on a wooden or masonry wall). The conduit is mounted on a wooden wall such that the gap between the conduit and the surface is less than 0.3 times the conduit diameter. The conduit can be metal or plastic. Where the carrying the non-sheathed or sheathed cable may be higher. Reference Method C (clipped direct), for example, Installation Method 20 (single-core or multicore cable on a wooden or masonry wall) Cable mounted on a wooden wall so that the gap between the cable and surface is less than 0.3 times the cable to or embedded in a masonry wall the current-carrying may be higher. NOTE: The term masonry is taken to included brickwork, concrete, plaster and similar (but excluding thermally insulating materials) in thermal insulation continuity conductor cables Method 100 Installation methods wooden joist above a plasterboard ceiling with a minimum U value 0.1 W/m²K and with thermal insulation no exceeding 100mm in thickness. twin and earth cable clipped direct to a wooden joist above a plasterboard ceiling with a minimum U value 0.1 W/m²K and with thermal insulation exceeding 100mm in thickness. cable in a stud wall with thermal insulation with a minimum U value 0.1 W/m²K with the cable touching the inner wall surface. Method Installation methods for thermal insulation with a minimum U value 0.1 W/m²K with the cable not touching the inner wall surface. position such that it will not be covered with thermal insulation. Regulation 523.7, BS : ppendix C: voidance overheating electric cables, Building Regulations pproved document B and Thermal insulation: avoiding risk. BR 262, BRE, 2001 refer. 21

24 CBLES FZE Mark Cables FZE S Street S900 Jebel li Free Zone South P.O.Box 17371, Dubai, UE Tel: , Fax: sales@markcables.com

CONTROL CABLES CABLES FZE.

CONTROL CABLES CABLES FZE. CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables

More information

6491B / H07Z-R / BS EN Cable

6491B / H07Z-R / BS EN Cable 6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES

PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES OVER PIONEER BY NAME. PIONEER BY DEED. YEARS OF SUCCESS Some Cables Love To Devour Power You Pay For Electricity flows through the copper strands inside

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

Catalogue. Index INDUSTRIAL CABLE

Catalogue. Index INDUSTRIAL CABLE Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

Single Core Cables 51

Single Core Cables 51 Single Core Cables 51 Single Core Cables PVC PVC Single Core Cables H05V-K /H07V-K Conductors: Flexible copper (class 5) Insulation: PVC Standards: HAR CENELEC Fire Performance: Flame retardant to IEC

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

Complete range of transformers for any applications or size

Complete range of transformers for any applications or size Complete range of transformers for any applications or size SURGE PROTECTOR KAB-15A(15A/110V) KAB-10A(10A/V) 3min delay Specifications: Input voltage: 160V to 40V Output voltage: 110/V +/- 3% Frequency:

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

PRODUCT CATALOGUE Volume 4

PRODUCT CATALOGUE Volume 4 PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

Building & Infrastructure Cables DELIVERING ENERGY

Building & Infrastructure Cables DELIVERING ENERGY Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines. 1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8 SY Cable Application: Measuring and control cable to connect equipment in production lines / assembly lines and conveyor systems. Can be used both fixed and flexible installations. Techincal Data: 1 Plain

More information

AN ISO 9001 : 2008 COMPANY

AN ISO 9001 : 2008 COMPANY R AN ISO 9001 : 2008 COMPANY Company Jigar dustries is one the largest manufactures " SIGMA" brand electric wires & cables in dia. The company has a experience manufacturing wires and cables for more than

More information

1 Conductor Class 5 flexible annealed plain copper conductor

1 Conductor Class 5 flexible annealed plain copper conductor YY Control Cable Application: YY Control is a flexible mulit-core cable with class 5 flexible annealed plain copper conductors, PVC insulation, and a grey PVC sheath. YY Cable is used in fixed installations

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data Content Page CONTENTS Page Introduction... 2 Customer Service... 3-4 Specification...5 Construction...6 Application...6 Technical Data...7-14 1.1 Unarmoured Cables with Overall Screened (TYPE 1)...7 1.2

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison. Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

SY PVC / BS EN Control Flexible Cable

SY PVC / BS EN Control Flexible Cable SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

FLEX-O-POWER FLEXIBLE WELDING

FLEX-O-POWER FLEXIBLE WELDING EQUIPMENT cables FLEX-O-POWER FLEXIBLE WELDING & POWER CABLE High conductivity bunched flexible annealed copper conductors, insulated with a soft flexible grade PVC suitable for welding and power purposes.

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

GEMSCAB has been associated with marketing and manufacturing of Electric Cables I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show. 1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction

More information

buildings. They are also used for industrial electrification regular intervals along with the size of the wire.

buildings. They are also used for industrial electrification regular intervals along with the size of the wire. P.V.C. INSULATED SOLID/ STANDED COPPE CONDUCTO CABLE Application : These cables are used for wiring domestic and commercial buildings. They are also used for industrial electrification Features : Manufactured

More information

THE UK S BENCHMARK FOR TRI-RATED CABLE

THE UK S BENCHMARK FOR TRI-RATED CABLE THE UK S BENCHMARK FOR TRI-RATED CABLE Welcome to Clynder Cables Clynder Cables has over thirty years of experience in the supply of UK manufactured industrial electrical cables to the UK, European and

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN LSOH Wiring Cables Low Voltage (/7 V) LSOH Conduit Wire (HO7ZR) 91B Cable Approvals Cable approved to BS711 Key Applications > Installation in surface mounted or embedded conduits, or similar closed systems

More information

H07RN-F TITANEX (industrial flexible)

H07RN-F TITANEX (industrial flexible) Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has

More information

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

Price List NATIONAL PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four Price List HSN Code : 8544 w.e.f. : 01.06.2018 "NATIONAL" PVC FLEXIBLE CABLE WITH COPPER CONDUCTOR SINGLE CORE 1.1 KV CONFORMING TO IS:694/2010. "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv POLYCAB WIRES PVT LTD TECHNICAL DETAILS HT XLPE S UPTO 45Kv C O N T E N T S INTRODUCTION ADVANTAGE OF POLYCAB XLPE S SELECTION OF S TECHNICAL DATA Conductor Resistance Current Rating Cable Short Circuit

More information

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH c A B L E 5 [B) Techno Flex manufacture high quality heavy duty power cable confirming to IS: 1554 (Part -1) L.T. 1100 volts grade CONSTRUCTION DETAILS:- Power Cable CONDUCTOR Plain bright annealed copper!

More information

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION H07V-K GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,

More information

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables cmi XLPE s PRODUCT CATALOGUE Electric Wire & s Complies to AS/NZ Standard cmi XLPE s www.cmielectrical.com.au A division of CMI Operions Pty Ltd ABN 87 088 279 270 For over 15 years XLPE s has provided

More information

I N T R O D U C T I O N

I N T R O D U C T I O N I N T R O D U C T I O N GEMSCAB are being manufactured by the people who have been associated with the industry for over years and understand the requirements their valued customers. The company took up

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

CONTENT PAGE ACL CABLES PLC 5-6 ACL FIRE ZERO 7-12

CONTENT PAGE ACL CABLES PLC 5-6 ACL FIRE ZERO 7-12 CONTENT ACL CABLES PLC 5-6 ACL FIRE ZERO 7-12 DATA TABLES-ACL FIRE ZERO 1 CORE EARTH CABLES - Cu / LSHF 450/750V 13 1 CORE EARTH CABLES FLEXIBLE - Cu / LSHF 450/750V 13 1 CORE Cu / LSHF / LSHF 300/500

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2010 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018 "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018 "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0. Table 12-1: current rating Technical Tables T12 Current ratings basic table ÖLFLEX For cables with a nominal voltage of up to 1000 V and for heat-resistant cables at an ambient temperature of +30 C. You

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved. PROTEC Screened Wiring Cable Updated to meet new requirements of BS 8436:2011 BASEC approved www.aeicables.co.uk PROTEC CABLES Manufactured and designed to BS 8436 and IS 273 Protec Low Smoke Zero Halogen

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai Wires & Cables About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

H07RN-F TITANEX PREMIUM

H07RN-F TITANEX PREMIUM New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET ER47 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Int Time Allowed: Three

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

3. Fire Resistant Cables

3. Fire Resistant Cables Fire Resistant Cables The -to-fire is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.

More information

PARAMOUNT COMMUNICATIONS LTD.

PARAMOUNT COMMUNICATIONS LTD. LT Power Cables - Aluminium conductor PARAMOUNT BRAND Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor,xlpe Insulated,cores laid up, PVC innersheathed,unarmoured/armoured

More information