Frequency changer variable speed pressure booster units
|
|
- Benjamin Walsh
- 5 years ago
- Views:
Transcription
1 NOCCHI Frequency changer Quiet operation, Constant pressure, Pipes in AISI 34, Superior frequency converter These are automatic pressure units for distribution networks with a single phase or three phase electrical power supply. The speed of the first pump which starts is modulated by the inverter, associated with an electronic card via a pressure transducer so that the outlet pressure of the unit remains constant, regardless of the amount of water withdrawn (within the maximum flow rate of the first pump). Whenever the quantity of water withdrawn exceeds the flow rate of the first pump, the second fixed-speed pump starts, whilst the first continues to be modulated by the inverter. When water withdrawal ceases, the pump below the inverter operates at a greater speed for an adjustable length of time in order to allow the accumulation of a certain quantity of water under pressure, which will delay the pause interval of the pump. SILENZIO PRESSIO TUBAZIO CONVER NUMBER OF PUMPS MAXIMUM FLOW RATE Main pumps Pilots L/min m 3 /h 2 - from 1 to 14 from 6 to from 15 to 21 from 9 to from 2 to 28 from 12 to 24 VLR 8 VLR 16 USAGE LIMITATIONS FDC2 FDC3 FDC4 FC.2 FC.3 FC.4 Maximum flow rate (m 3 /h) Maximum head (m.c.a.) VLR 32 USAGE LIMITATIONS FC.2 FC.3 FC.4 SILENZIOSO PRESSIONE TUBAZIONI CONVERTIT Maximum flow rate (m 3 /h) Maximum head (m.c.a.) 89 Max. operating pressure 16 bar Supply voltage 4 V Direct pump start Direct up to 7.5 inclusive. Star / triangle starter over 7.5 Operating frequeny 25-5 Hz Ambient temperature +5 C Protection clas electric pumps IP55 IP44 for MULTINOX-VE Protection class electric control panel IP54 21
2 NOCCHI Frequency changer Electric pumps VLR: Centrifugal, multicellular vertical axis BASEMENT Edging in galvanised steel Discharge manifold In galvanized steel with: n. 1 pressure gauge n. 1 pressure transducer -5Volt -1 Bar n. 1 ball bearings in brass * SUCTION MANIFOLD * components provided for each electric pump installed In stainless steel AISI 34 with: n. 1 sleeve for loading water n. 1 ball bearings in brass * n. 1 check valve * ELECTRIC PUMP stop valve PRESSURE gauge non-return valve CONTROL PANEL LOW PRESSURE SWITCH transducer 22
3 NOCCHI Frequency changer CONTROL PANEL - PILOT ELECTRIC PUMP Electric control panel IP54 metallic casing General switch Keyboard with SV electronic card Interface card, inverter Inverter for first pump started Fuses, contactors and thermal relay for each pump Star-triangle starter for pumps with power over 7.5 Transformer with fuses for the auxiliary circuit M-O-T selector for each pump MAIN FUNCTION ICyclic inversion of the starting order of the pumps after the end of every operation cycle Timing adjustable from to 255 sec. of pump operation after the contact of the pressure switch has been opened or after the operating pressure has been reached ON/OFF control of the level of the first gathering tank or of the pressure in the supply pipe through a float switch or an inverse differential pressure switch Sequential control of starting of pumps to avoid pumps from starting off at the same time External command devices One differential pressure switch (ON/ OFF adjustable) for each pump, or One electronic pressure transducer (-5 V) Float ON/OFF switch situated in the water collection tank, or n. 3 electrodes for the electronic control of the level of water in the first collection tank Inverse pressure switch inserted in the water supply pipe (mains) Signaling and commands LCD indicating operating parameters and entering configuration and calibration values Led indicator to signal the presence of electrical power Led indicator to signal low level of water in the first collection tank or insufficient pressure in the water supply pipe (mains) Led indicator to signal the trigger of the overload thermal relays Led indicator to signal Manual or Automatic operation Led indicator to signal that each pump is working correctly Buttons for selecting Manual or Automatic operation Start / Stop button for each pump if manual operation is selected Button for inserting configuration parameters Accessories Frequency changer accessories available on request Float switch for protection against dry running Differential pressure switch for cut-out in the event of insufficient mains pressure Electrodes for checking electronic level Diaphragm autoclaves FCD FCY X X X X 23
4 BLOCCO LINEA AUT MAN TERMICO ANOMALIA M A P1 I P2 I P3 I P4 I ENTER P5 I F A S I L1 L2 L3 (R) (S) (T) VOLT AMPERE VOLT AMPERE 1 NOCCHI FCD2 - VLR FCD2 - VLR4/ FCD2 - VLR4/1 FCD2 - VLR4/8 FCD2 - VLR4/8-7 FCD2 - VLR4/6 FCD2 - VLR4/5 FCD2 - VLR4/4 FCD2 - VLR4/ DNA DNM H5 H1 P1 P2 F L2 L1 L/ m 3 / h 4,8 6 7,3 8,4 9,6 1, ,2 14,4 15,6 FCD2-VLR4/3 2x, , ,5 22 2, FCD2-VLR4/4 2x, , , FCD2-VLR4/5 2x1, , FCD2-VLR4/6 2x1, , , FCD2-VLR4/8-7 2x1, , , , FCD2-VLR4/8 2x1, ,5 5 43, FCD2-VLR4/1 2x2, , , FCD2-VLR4/12 2x2, , ,5 Weight (Kg) FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/ FCD2-VLR4/
5 NOCCHI FCD2 - VLR FCD2 - VLR8/1 9 FCD2 - VLR8/8 7 FDC2 - VLR8/6 5 FCD2 - VLR8/5 FCD2 - VLR8/4 3 FCD2 - VLR8/ LO Dimensioni in mm Peso L/ Kg 4 m 3 / h FCD2-VLR8/3 2x1, FCD2-VLR8/4 2x1, FCD2-VLR8/5 2x2, FCD2-VLR8/6 2x2, FCD2-VLR8/8 2x FCD2-VLR8/1 2x FCD2-VLR8/ /2 2 1/ FCD2-VLR8/ /2 2 1/ FCD2-VLR8/ /2 2 1/ FCD2-VLR8/ /2 2 1/ FCD2-VLR8/ /2 2 1/ FCD2-VLR8/ /2 2 1/
6 NOCCHI FCD2 - VLR FCD2 - VLR16/7 9 FCD2 - VLR16/6 7 FCD2 - VLR16/5 5 FCD2 - VLR16/4 3 FCD2 - VLR16/ LO L/1 2 Dimensioni 4 in mm Peso Kg m 3 / h FCD2-VLR16/3 2x FCD2-VLR16/4 2x FCD2-VLR16/5 2x5, FCD2-VLR16/6 2x5, FCD2-VLR16/7 2x7, FCD2-VLR16/ / FCD2-VLR16/ / FCD2-VLR16/ / FCD2-VLR16/ / FCD2-VLR16/ /
7 NOCCHI FC.2 - VLR FCY2 - VLR32/6 FCY2 - VLR32/ FCD2 - VLR32/4 5 FCD2 - VLR32/ L/ m 3 / h FCD2-VLR32-3 2x5, FCD2-VLR32-4 2x7, FCY2-VLR32-5 2x FCY2-VLR32-6 2x11 16,2 94,2 82,2 66 4,8 Weight (Kg) FCD2-VLR FCD2-VLR FCY2-VLR ** * FCY2-VLR ** * * Weight refers to units with electric pumps. **Height refers to electric pumps - electric control panel supplied separately with control box weight 124 kg 27
8 NOCCHI FCD3 - VLR FCD3 - VLR8/1 FCD3 - VLR8/8 7 FDC3 - VLR8/6 5 3 FCD3 - VLR8/5 FCD3 - VLR8/4 FCD3 - VLR8/ L/ m 3 / h ,5 36 FCD3-VLR8/3 3x1, FCD3-VLR8/4 3x1, FCD3-VLR8/5 3x2, FCD3-VLR8/6 3x2, FCD3-VLR8/8 3x FCD3-VLR8/1 3x FCD3-VLR8/ / FCD3-VLR8/ / FCD3-VLR8/ / FCD3-VLR8/ / FCD3-VLR8/ / FCD3-VLR8/ /
9 NOCCHI FCD3 - VLR FCD3 - VLR16/7 FCD3 - VLR16/6 7 FCD3 - VLR16/5 5 FCD3 - VLR16/4 FCD3 - VLR16/ L/ m 3 / h FCD3-VLR16/3 3x FCD3-VLR16/4 3x FCD3-VLR16/5 3x5, FCD3-VLR16/6 3x5, FCD3-VLR16/7 3x7, FCD3-VLR16/ FCD3-VLR16/ FCD3-VLR16/ FCD3-VLR16/ FCD3-VLR16/
10 NOCCHI FC.3 - VLR FCY3 - VLR FCY3 - VLR32-5 FCD3 - VLR FCD3 - VLR L/ m 3 / h FCD3-VLR32-3 3x5, FCD3-VLR32-4 3x7, FCY3-VLR32-5 3x FCY3-VLR32-6 3x ,8 FCD3-VLR FCD3-VLR FCY3-VLR ** * FCY3-VLR ** * * Weight refers to units with electric pumps. **Height refers to electric pumps - electric control panel supplied separately with control box weight 124 kg 3
11 NOCCHI FCD4 - VLR FCD4 - VLR8/1 9 FCD4 - VLR8/8 7 FDC4 - VLR8/6 5 FCD4 - VLR8/5 FCD4 - VLR8/4 3 FCD4 - VLR8/ LO Dimensioni in mm Peso L/ Kg m 3 / h FCD4-VLR8/3 4x1, FCD4-VLR8/4 4x1, FCD4-VLR8/5 4x2, FCD4-VLR8/6 4x2, FCD4-VLR8/8 4x FCD4-VLR8/1 4x FCD4-VLR8/ FCD4-VLR8/ FCD4-VLR8/ FCD4-VLR8/ FCD4-VLR8/ FCD4-VLR8/
12 NOCCHI FCD4 - VLR FCD4 - VLR16/7 9 FCD4 - VLR16/6 7 FCD4 - VLR16/5 5 FCD4 - VLR16/4 3 FCD4 - VLR16/ L/ m 3 / h FCD4-VLR16/3 4x FCD4-VLR16/4 4x FCD4-VLR16/5 4x5, FCD4-VLR16/6 4x5, FCD4-VLR16/7 4x7, FCD4-VLR16/ FCD4-VLR16/ FCD4-VLR16/ FCD4-VLR16/ FCD4-VLR16/
13 NOCCHI FC.4 - VLR FCY4 - VLR32/6 FCY4 - VLR32/ FCD4 - VLR32/4 5 FCD4 - VLR32/ L/ m 3 / h FCD4-VLR32-3 4x5, FCD4-VLR32-4 4x7, FCY4-VLR32-5 4x FCY4-VLR32-6 4x ,8 FCD4-VLR FCD4-VLR FCY4-VLR ** * FCY4-VLR ** * * Weight refers to units with electric pumps. **Height refers to electric pumps - electric control panel supplied separately with control box weight 165 kg 33
PVM 5 PVM 10 PVM 15 PVM 20 PVM 32 FCD20 FCD 20 FCD 30 FCD 40 FC. 20 FC. 30 FC. 40 FC. 20 FC. 30 FC. 40 FC. 20 FC. 30 FC. 40
NOCCHI Frequency changer Silent, constant pressure, piping in AISI 34, quality frequency converter They are booster set for the automatic pressurization of water distribution networks with three-phase
More informationNOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED
NOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 SILENT OPERATION, CONSTANT PRESSURE, PIPELINES IN AISI
More informationPRESSURE BOOSTER SETS WITH TRANSDUCER CONTROL COMPACT, ROBUST, HIGH HYDRAULIC PERFORMANCE, PIPELINES IN AISI 304 STAINLESS STEEL. each pump etc.).
NOCCHI SENSORMAT COMPACT, ROBUST, HIGH, PIPELINES IN AISI 34 STAINLESS STEEL Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 These are automatic pressure booster sets
More informationAPPLICATION DATA CB MULTINOX-XC MULTINOX-A MULTINOX-VE DHR VLR 2B VLR 4
NOCCHI EASYBOOST RESIDENTIAL - COMPACT, ROBUST, HIGH HYDRAULIC PERFORMANCE, RELIABLE Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 FEATURES NEW These are units for
More informationAUE-AUD-AU2E AU2D-AUED
AUE-AUD-AU2E AU2D-AUED EN12845 Fire Pump Stations Designation of AUE 120 / 100 - N 80-250/75 + DJ MV 708 AUE: One electric main pump + jockey 120: Rated Flow (m 3 /h) 100: Rated Pressure (Hm) N 80-250/75:
More informationPressure boosting Irrigation Industrial washing equipment Water distribution Building
NOCCHI CPS Easy installation, Energy saving, Silent running, Reliability CPS energy savings control system keeps constant delivery when pressure variations occur. CPS is a frequency converter integrated
More informationVARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES
VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h 50 Hz SERIE GHV10 GHV20 GHV30 GHV40 SERIES EDITION 10-2005 CONTENTS Range... 3 Operation description...
More informationHydrovar and Packaged Hydrovar
Hydrovar and Packaged Hydrovar MOTOR MOUNT VARIABLE SPEED PUMP CONTROLLER AND INTEGRATED PUMP PACKAGES BRHYDROVAR R3 Goulds Water Technology Hydrovar and Packaged Hydrovar Hydrovar Variable Speed Drives
More informationControl panel. For 3 three-phase electric pumps with thermal protection and exchanger
AUTOCLAVES PRODUCTS Control panel For 3 three-phase electric pumps with thermal protection and exchanger General features: Electromechanic panel with electronic control Sequence exchanger for 2 electro
More informationAqueducts Irrigation Water distribution Industrial applications APPLICATION DATA
NOCCHI NRB STANDARDIZED CLOSE COUPLED CENTRIFUGAL PUMPS (2-4 POLE) RUGGED AND RESISTANT, WIDE RANGE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 The electric pumps
More informationBENECOR DEF CENTRIFUGAL PUMP
BENECOR DEF CENTRIFUGAL PUMP Benecor s Centrifugal Pumps are specifically designed and engineered for pumping DEF. Strong delivery pressure makes it ideal for use in supplying DEF from storage tanks. This
More informationVigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION
V2P/V2T Vigilec doble INSTALLATION AND OPERATION V2P V2T Pump controlller and protection for two (3ph/1ph) pumps (V2P: control by pressure switches/ V2T: control by pressure transducer) General Description
More information1 KDN FIRE -FIGHTING BOOSTER SETS UNI EN12845 WITH ELECTRIC PUMP AND DIESEL PUMP
Pressurization units for sprinkler system designed according to European standard EN 12845 The European Standard EN 12845 stated that units must be set up : - 1 electrical - 1 diesel - 2 electrical s -
More informationEN ELECTRIC PUMP EN ENGINE-DRIVEN PUMP
Pressurization units for sprinkler system designed according to European standard EN 12845 The European Standard EN 12845 stated that units must be set up : - 1 electrical - 1 diesel - 2 electrical s -
More information331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH
331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing
More informationFIREPAK-E21 & FIREPAK-ED21
FIREPAK-E21 & FIREPAK-ED21 Fire Pumps Set Designation of FIREPAK - E 2 1-120 / 80 - WTM 80-250 / 55 + DJ MV FIREPAK: Package Type E: All pumps in the set electric driven 2: No. main pumps 1: no. jockey
More informationMATRIX Booster Sets Data Book 50Hz
Japanese Technology since 9 MATRIX Booster Sets Data Book 50Hz 50Hz CONTENTS INDEX GP-GPE Page CONTENTS INDEX DEFINITION AND USE OF PRESSURISATION UNITS 0 TYPICAL APPLICATIONS 0 PRINCIPLE OF OPERATION
More informationLPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning
In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants
More informationA LEADER IN WATER TECHNOLOGY
A LEADER IN WATER TECHNOLOGY The Pentair Water Group is one of the world s leading companies in the planning and manufacture of innovative products and systems suitable in any situation requiring the treatment,
More informationDuplex Commercial Pressurizer -DCP
Duplex Commercial Pressurizer -DCP Pre-Engineered Two-Pump Booster Reliable, Efficient and Easy Thrush Duplex Commercial Pressurizer Thrush Duplex Commercial Pressurizers are pre-engineered pressure booster
More information2 EURO PUMP SETS. GENERAL DATA Applications. Construction features - components
2 EURO PUMP SETS GENERAL DATA Applications Booster sets specifically suitable for domestic applications and small systems for civil, agricultural or industrial uses. These sets are acclaimed for their
More informationGS Series. with new controller SM30
GS Series Sensorpress Booster Systems with new controller SM30 GS Series The GS range of fixed speed booster setsincludes models with 2 to 3 electric service pumps, and an additional jockey pump able to
More information.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.
Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout
More informationDesigned for ease of integration with automation systems
BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from
More informationPUMPS SURFACE C ATA L OGU E SURFACE PUMPS
SURFACE C ATA L OGU E PUMPS SURFACE PUMPS www.vansan.co.za IDB Series Peripheral Pumps 8 ISO2548-C 22V/5HZ 6 4 2 5 1 2 25 35 4 45 l/min IDB4 IDB35 IDB6 IDB7.3.6.9 1.2 1.5 1.8 2.1 2.4 2.7 m 3 /h Ampere
More information4 submersible pumps powered by renewable energy sources
submersible pumps powered by renewable energy sources ENGLISH TCH technology applied to renewable energy The pumps, owered by renewable energy sources, is a new range coming from the TCH pumps with built-in
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationWATERPRESS BOOSTER SETS WITH 24L HORIZONTAL EXPANSION TANK. Design features
WATERPRESS BOOSTER SETS WITH 24L HORIZONTAL EXPANSION TANK The WATERPRESS booster sets are made up of JET self-priming centrifugal pumps. They are supplied wired, tested and complete with 24l expansion
More informationBENECOR ELECTRIC MOTOR BASE DEF PUMP PACKAGE
BENECOR ELECTRIC MOTOR BASE DEF PUMP PACKAGE Built based on the most requested package, Benecor s Electric Motor Base DEF Pump Package includes: electric motor, nozzle, 10 ft. EPDM flexible hose, 47 in.
More informationGS20-GS21-GS30 Series
GS-GS1-GS3 Series Fixed-speed pressure booster sets with Vertical Multistage electric pumps e-sv series Hz CONTENTS General introduction...3 Choice and selection...4 11 GS.../SV Series...11 13 Range...13
More informationCENTRIFUGAL PUMPS according to DIN standard
CENTRIFUGAL PUMPS according to DIN 2255 standard End suction centrifugal pumps in accordance with DIN 2255 made of cast iron, applications in water boosting, heating system, airconditioning, washing systems
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303
SPECIFICATIONS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY 203 PERFORMANCE CHART 2 204 PERFORMANCE CHART 4 205 PERFORMANCE CHART 7 206 PERFORMANCE CHART 15 207 - CONSTRUCTIONS
More informationTechnical specifications
Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith
More informationPATTERSON PUMP COMPANY
PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL
More informationDRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations
DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER The DRENOX series pumps are built entirely in AISI 304 stainless steel. Cooling of the motor is via a heat exchange chamber that allows the machine
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationSTANDARDIZED MONOBLOC CENTRIFUGAL PUMPS (2-4 POLE) RUGGED AND RESISTANT, WIDE RANGE, HIGH HYDRAULIC PERFORMANCE
NOCCHI NRM RUGGED AND RESISTANT, WIDE RANGE, HIGH HYDRAULIC PERFORMANCE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 The pumps in the NRM series are monobloc single
More informationDegree of protection: IP 55 Power supply voltage: 230V/ 1F 50 Hz External dimensions: mm Weight: Kg 0.6
NOCCHI QES PLUS Single phase electrical panel to control a submersed pump with direct start MIN COMPONENTS Plastic casing IP 55 Switch with circuit breaker Motorprotector with reset button Starting capacitor
More informationLiebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller
DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationApplication Engineering
Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationHITACHI ELECTRIC CHAIN HOISTS
HITACHI ELECTRIC CHAIN HOISTS Hitachi s reputation for excellence in design, quality, reliability and performance has made this brand a global market leader. With over three decades of proven reliability
More informationGH Hydro Kits. Technical Information. Ref: N
GH Hydro Kits Ref: N-27167 0507 Technical Information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory
More informationSUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017
EFFECTIVE: 7/24/2017 STEAM SAFETY VALVES 99136 100 PSIG 1/2" NPT (ES12 to ES72) 99137 100 PSIG 1" NPT (ES84 to ES180) 99132 15 PSIG 1/2" NPT (ES12 to ES48, HU40 to HU140) 99297V 15 PSIG 3/4" NPT (ES60
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationELECTRIC SUBMERSIBLE PUMPS SEMISOM/80
Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic
More informationChiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw
Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic
More informationSECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS
SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationGEN Series with Diesel Engine Pumps
GEN Series with Diesel Engine Pumps Fire-fighting booster sets EN 1284, high-efficiency electric pumps with PLM motors and series FHF and SHF horizontal centrifugal diesel engine pumps Hz WEB 11-29 2 CONTENTS
More informationLowara UK Variable Speed Booster Sets
Lowara UK Variable Speed Booster Sets Your trusted partner The professionals in pump technology across all building services Lowara is a leading supplier of pump technology to the building services industry.
More informationVariable Speed Booster. Sets With IMAT Control
Variable Speed Booster Sets With IMAT Control IMAT CONTROL Benefits Flexibility I-MAT frequency converters are equipped with a software which provide different operating modes in order to cover a wide
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More information4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH
submersible pumps with integrated electronics powered by renewable energy sources ENGLISH HS technology applied to renewable energy HS MultiPower pumps (HS MP), powered by renewable energy sources, is
More informationChiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.
Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high
More informationGeneral introduction...5. Characteristics of electric pumps...9. Accessories and main components Choice and selection Range...
Hz GEN Series FIRE-FIGHTING BOOSTER SETS EN 1284 WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FHF and SHF SERIES EQUIPPED WITH HIGH EFFICIENCY MOTORS Cod. 19141 Rev ev.a Ed.11/211 2 CONTENTS General introduction...
More information4 variable speed submersible pumps
4 variable speed submersible pumps HIGH EFFICIENCY ENERGY SAVE nastec.eu 4HS is a range of 4 electric submersible pumps for well applications, featuring: Three-phase, water-filled, permanent magnet synchronous
More informationApplication Engineering Europe
Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationPriox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment
NOCCHI Lenntech info@lenntech.com Tel. +31-152-1-9 www.lenntech.com Fax. +31-152-1-289 The new range NOCCHI Priox waste water treatment submersible vortex pumps for waste water Nocchi Priox Submersible
More informationRT2DB Excitation and voltage regulation system for synchronous generators
s RT2DB Excitation and voltage regulation system for synchronous generators Fully digital. Parameter settings done by software. Self monitoring routines. Maintenance free. High reliability. Excellent dynamic
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationEclipse 2000 Service Parts
This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior
More informationWadi Mai Item Description Status UOM Quantity
Wadi Mai Item Description Status UOM Quantity 10281 BEARING New NOS 2.00 10884 SWITCH DIMMER ASSY New NOS 1.00 12451 AIR FILTER New NOS 1.00 12452 FILTER SUCTION New NOS 2.00 12454 V-BELT New NOS 4.00
More information50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES. Cod.
Hz GS-GS1-GS3 Series FIXED-SPEED PRESSURE BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES Cod. 1911 Rev ev.a.a Ed.11/11 CONTENTS General introduction...3 Choice and selection...4 11 GS.../SV
More informationCENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies
Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationAdvantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.
Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303
SPECIFICATIONS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY 203 PERFORMANCE CHART 2 204 PERFORMANCE CHART 4 205 PERFORMANCE CHART 7 206 PERFORMANCE CHART 15 207 - CONSTRUCTIONS
More informationCONTENTS. Earth leakage and overload/short circuit protection systems with self-reclosing Associated breaking element
Earth leakage and overloads short-circuit protection with self-reclosing P 2 P.2.01 GB CONTENTS Associated breaking element Page Earth leakage protection systems with self-reclosing 3-4 Parameters related
More informationOn Demand, Differential Pressure Controls
On Demand, Differential Pressure Controls 20 Series Pulse Controller The Goyen 20 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic
More informationTotal Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007)
Total Control Board (From October 2007) Publication 2949A (GB) 1108 Freedom from patent restrictions must not be assumed. IMPORTANT PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLATION THIS MANUAL SHOULD
More informationMPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene
MPS AND MPS PR¼ 16 OUTPUT DEMAND PENTAIR CLEAN AIR SYSTEMS MPS DESCRIPTION The Model MPS has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing
More informationCentrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL
Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationCommercial Pressure Booster Systems
Commercial Booster Systems Aqua P ro Pump Systems a Tomiko Inc. Company Packaged Booster Systems Package water pump system consists of pump(s), pressure tank, pressure sensor(s), flow switch, pressure
More informationTDX - Taco Duplex Starter with
Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationFEED WATER REGULATOR EVM-1F FOR CONTINUOS REGULATION
1. Feed water regulator type EVM 1 F 2. Electrode stand type C DN 50 100 / PN 16 100 with 2 electrodes type ENT 120. 3. Control range 15 mm. 4. HORA Feed water regulating valve with electric actuator.
More informationAurora Single Phase Emergency Lighting Inverters
Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available
More information3/3-Way-Proportional Valve
3/3-Way-Proportional Valve Content Page General Description 1 Design 2 Function 2 Technical Data 3 Options 4 Dimensions 5 Accessories 6 Flow Curves 7 General Description This proportional valve in combination
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationInstallation, Operation and Maintenance Manual. EVC Controller (from February 2007)
Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationHG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS
H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationPRODUCT CATALOG 50 HZ MH SERIES HORIZONTAL MULTI-STAGE PUMPS. franklinwater.com
PRODUCT CATALOG 5 Z M SERIES ORIZONTAL MULTI-STAGE PUMPS franklinwater.com 5 Z M SERIES ORIZONTAL MULTI-STAGE PUMPS Features...2 Applications...2 Model Nomenclature...2 Family Curve...3 Materials/Fluids
More informationMD - MMD. MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron. Japanese Technology since Commercial
MD MMD Cast iron monobloc centrifugal pumps conforming to en 733. APPLICATIONS Handling of clean water for civil, agricultural, industrial uses and for pressurisation units, heating plants and air conditioning
More informationFunctions provided by measuring relays in railway equipment
Functions provided by measuring relays in railway equipment 1-Current relays -Minimum current relays (During normal operation, if the current is present these relays are in operating position and switch
More informationMaxPak Plus Analog DC V S Drive
Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More information1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION
1-3 MANUAL STARTERS EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION Motor starters are made out of power switches and overload protection devices. They can be
More informationThe Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP
The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes
More information