PRODUCT LINE SHEET. Honesty. Integrity. Honor

Size: px
Start display at page:

Download "PRODUCT LINE SHEET. Honesty. Integrity. Honor"

Transcription

1 PRODUCT LINE SHEET Honesty. Integrity. Honor

2 WHO WE ARE At HB, we are dedicated to serving the Electrical Community through the distribution of electrical supplies. We strive to offer the best customer service through the knowledge of the products we carry, lightning fast response times and friendly personnel. Houston Breakers and Electrical Supplies was established in 1999 and remains family owned and operated. We believe strong families and faith in God are essential in the success and growth of our nation. Thank you for the opportunity to serve you. Great people and service. We ve been using Houston Breakers for a year now to help save our clients Money. -Ryan, Purchasing Agent, TX This company demonstrates what quality, integrity and customer service is all about! -Tracy, Master Electrician, TX The guys at Houston Breakers are professional, knowledgeable, friendly and they treat me like family and not just a customer. -Earl, Master Electrician, TX

3 CIRCUIT BREAKERS...2 MOUNTING HARDWARE...3 DISTRIBUTION PANELS...4 PANELBOARDS...5 LOADCENTERS...6 SAFETY SWITCHES...8 TRANSFORMERS BUS PLUGS PANELBOARD SWITCHES...12 STARTERS & CONTACTORS CONTROLS...15 METER CANS & GUTTERS TOOLS SAFETY GEAR CUSTOM FABRICATION...19 SERVICES WILL CALL HOT SHOT DELIVERY SAME DAY SHIPPING EMERGENCY/AFTER HOURS SERVICE

4 MOLDED CASE CIRCUIT BREAKERS Amps 120/208/240/480/600 Volt 5-200kAIC Rated Thermal Magnetic Electronic Trip Motor Circuit Protectors Molded Case Switch SIEMENS We have the breaker you need no matter what the job demands. SQUARE D

5 CIRCUIT BREAKERS MANUFACTURERS Square D Siemens General Electric Eaton/Cutler-Hammer Westinghouse Challenger ABB Federal Pacific Zinsco GENERAL ELECTRIC EATON/CUTLER-HAMMER Shunt Trips Auxiliary Contacts Under Voltage Release Bell Alarms Lockout-Tagout Handle Ties Flange & Rotary Handles Enclosures

6 MOUNTING HARDWARE Amps Single & Twin Mount Panel Types ITE/SIEMENS - FC1, FCII, SB1-3, CDP 5/6, S5, P5, SPP, S4, P4, FC20, VB General Electric - NAB, NHB, AV1, AV2, CCB, QMR, APN, APN-B, SCP Plus Eaton/Cutler-Hammer - PRL3a, PRL4a, PRL4b, PH6, CS5, CS7, MP40, MP50, MP100, MP200 Westinghouse - CDP, FDP, PRL3a, PRL4a, PRL4b Challenger - PM3a, PM4A, PM4b Federal Pacific - CDP, BDP We stock a wide range of Mounting Hardware for distribution panelboards. Feel confident during your next shutdown with our complete replacement mounting hardware kits

7 DISTRIBUTION PANELS Main Distribution Panels Amp Main Lug & Main Breaker V 3 Phase 4 Wire NEMA 1 (Indoor) NEMA 3R (Outdoor) Call for custom quotes over 1200A SQUARE D - I-LINE PANEL

8 PANELBOARDS Siemens P1 Lighting Panelboards Amp 1-Phase or 3-Phase 120/208/240/480 Volt Field Convertible to Main Lug or Main Breaker Feed-Thru Lugs or Subfeed Breaker without changing enclosure size Copper Bussing NEMA 1 (Indoor), NEMA 3R (Outdoor), NEMA 4X (Stainless Steel)

9 LOADCENTERS Siemens PL/ES Series Loadcenters Main Lug and Main Breaker Amp 1-Phase & 3-Phase Plug-in Branch Breakers - (PL,ES) Convertible from Main Lug to Main Breaker and vise versa (PL) Invertible for bottom feed applications (PL) NEMA 1 (Indoor) or NEMA 3R (Outdoor) Copper Bussing (PL) Aluminum Bussing (ES)

10 Disconnects Safety Switches General Duty & Heavy Duty Amp Vac 1-Phase & 3-Phase Fusible & Non-Fusible NEMA 1, NEMA 3R & NEMA 4/4X Suitable for use as service entrance *Special Order Bolt Switches up to 6000 Amps

11 SAFETY SWITCHES Double Throw Safety Switches General Duty & Heavy Duty Amp 1-Phase and 3-Phase Fusible & Non-Fusible NEMA 1 & NEMA 3R Suitable for use as service entrance Double throw switches are intended to transfer loads from one power source to another

12 Dry Type Distribution Transformers kva 1-Phase & 3-Phase Suitable for Reverse Feed Common Voltages: 480 Delta Primary Volts 208Y/120 Secondary Volts 3Ø, 60Hz 480 Delta Primary Volts 240 Delta/120 Tap Secondary Volts 3Ø, 60hz 240 Delta Primary Volts 208Y/120 Secondary Volts - 3Ø, 60Hz 240 x 480 Primary Volts 120/240 Secondary Volts 1Ø, 60Hz Auto Transformers kva 600 Primary Volts 480 Secondary Volts 3Ø, 60Hz 480 Primary Volts 380 Secondary Volts 3Ø, 50/60 Hz

13 TRANSFORMERS Buck-Boost Transformers From 95 to 500 Volts, sizes up to 360 kva 1-Phase and 3-Phase Reduce (buck) or raise (boost) line voltage from 5-20% Flexibility in kva sizes and input/output voltage combinations Lower Cost compared to a standard isolation transformer Industrial Control Transformers VA: Open core and coil Volts Copper windings Primary and secondary fuse protection VA: Fully encapsulated and enclosed Volts Copper windings UL and UL-3R listed

14 BUS PLUGS Amps Volts Fusible or Breaker Type Manufacturers Square D I-Line I or II (PQ Series) Fusible or Breaker Type General Electric Armor Clad AC Flex-A-Power FVK Spectra SB/SL Fusible or Breaker Type 11. Cutler-Hammer/Westinghouse Pow-R-Way III ITAP TAP Fusible or Breaker Type Siemens/ITE Bulldog - BOS XLX RV XLU UV Sentron Series Fusible or Breaker Type

15 PANELBOARD SWITCHES Amps Vac Single & Twin Mount Manufacturers QMB QMBW QMJ Square D Saflex Series D2 Series E1 Series General Electric Spectra ADS THFP QMR Cutler-Hammer/Westinghouse FDPW EE FDP Siemens/ITE Vacu-Break Switches

16 NEMA Starters Square D Siemens/Furnas Cutler-Hammer/Westinghouse General Electric Sizes 00-6, 600 Vac maximum Coils Vac Thermal & Solid State Overload Relays NOW STOCKING SIEMENS ESP200 Overloads Adjustable Current Range Overload, phase failure, phase unbalance, ground fault Class 5/10/20/30 Selectable Reset options (Manual, Automatic & Remote) IEC Starters and Contactors Large range of sizes compared to NEMA More closely match to load or application Generally half the size of a NEMA Starter DIN Rail mountable Adjustable Thermal and Electronic Overloads Lower Cost

17 STARTERS & CONTACTORS ABB VFDs and Soft Starters Available upon request Ranges from Horsepower Micro Drives General Purpose Drives Machinery Drives Soft Starters Definite Purpose Contactors Amps 2,3 & 4 Pole Coils Vac Lighting Contactors 1-12 Pole N.O & N.C Electrically held & Mechanically held 2 & 3 Wire Control Modules Remote Control Switch Amp, V Coils Separate Mounting or Direct mounting within Lighting Panelboards

18 CONTROLS Combination Starters Fusible & Non-Fusible Breaker Style Hand Off Auto Start Stop Build To Order Enclosures NEMA 1, NEMA 12, NEMA 3R & NEMA 4/4X Pilot Devices 22 & 30mm Pilot Lights Selector Switches Push Buttons Start Stop Stations Emergency Stops

19 METER CANS & GUTTERS Milbank Meter Cans 1-Phase & 3-Phase Amp Centerpoint Energy, Houston TX Amp 4 Terminal Ring Type 200 Amp 5 & 7 Terminal Ring Type 320 Amp 4,5 & 7 Terminal Residential/Light Commercial Entergy, Houston TX 125 Amp 4 & 7 Terminal 200 Amp 4, 5 & 7 Terminal 320 Amp 5 & 7 Terminal Heavy Duty Gutters NEMA 1 (Indoor) NEMA 3R (Outdoor) Sizes from 4x4x24 12x12x120 E-Mon D-Mon Class 1000 Single-Phase Class 2000 Three-Phase

20 TOOLS Pliers, strippers, cutters, crimpers, screwdrivers, levels and measuring tools, clamp meters, fish tapes, conduit tools, tool bags, pouches and more. 2-Piece Set of 4 Insulated Screwdriver All Purpose Pliers, Spring Loaded Cat. No. J206-8C Self-Adjusting Wire Stripper /Cutter Cat. No Heavy Duty Side Cutting Pliers Insulated Cat. No NE-EINS T-Handle Set with Stand Cat. No. JTH610E Digital Clamp Meter AC Auto-Ranging Temp Cat. No. CL210 Non-Contact Voltage Tester Flashlight Cat. No. NCVT-3 Tradesman Pro Camo Backpack Cat. No BP14CAMO Camouflage Zipper Bag Cat. No. 5139C Tradesman Pro Extreme Electricians Bag Cat No Insulated Tools Individually tested to exceed the IEC and ASTM F1505 Standards, marked with the official 1000-volt rating symbol

21 SAFETY GEAR HEAD PROTECTION PROTECTIVE EYEWEAR SAFETY GLOVES HI-VIZ APPAREL KNEE PROTECTION 18.

22 CUSTOM FABRICATION Custom Electrical Service Entrance & Enclosure Products Custom NEMA Enclosures Cable Tap Boxes (2,000-10,000 AMPS) Bussed Weatherheads (1200-4,000 AMPS) Switch Racks Bussed Gutters (400-4,000 AMPS)

23 SERVICES We stock what the others don t and even more of what they do. Cut time and money with in stock availability on most of our products. Custom Build to order material have minimum lead times. All products are backed with our 1 Year Warranty. Why choose Houston Breakers? Extensive inventory from several major brands. We have what you need, when you need it. A team of knowledgeable and dedicated sales staff. In stock hard-to-find and obsolete products. Same day pick-up/shipping. Delivery options available. Our fast response and in stock availability saves you time - and time is money. Blessed is the nation whose God is the LORD. Psalm 33:12 Honesty. Integrity. Honor

24 CONTACT US Pick-Up/Sales/Shipping 308 W. Hamilton St. Houston, TX Mailing Address PO BOX Houston, TX Business Hours 7:00-4:30 M-F TOLL FREE LOCAL Your source for electrical supplies

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

(337) FAX

(337) FAX SECONDCIRCUITS.COM FASTEST LEAD TIMES ON CUSTOM PANELS 1-2 week delivery normal 1 DAY SHIP AVAILABLE UL508A SHOP 1-888-463-2759 (337)785-9343 FAX SALES@SECONDCIRCUITS.COM TABLE OF CONTENTS About Us 3 Rentals

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

MANUAL STARTERS AND SWITCHES EBOOK

MANUAL STARTERS AND SWITCHES EBOOK 30 December, 2017 MANUAL STARTERS AND SWITCHES EBOOK Document Filetype: PDF 134.54 KB 0 MANUAL STARTERS AND SWITCHES EBOOK Manual motor starters can provide On/Off operation and overload protection. For

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

Ge 600 Manual Transfer Switch 200 Amp Nema 3r

Ge 600 Manual Transfer Switch 200 Amp Nema 3r Ge 600 Manual Transfer Switch 200 Amp Nema 3r Generac offers more options for transfer switches than any other manufacturer. Generac offers a full line of Industrial Transfer Switches to meet varying 100-800,

More information

Nema Manual Circuit Breaker Schematic Symbol READ ONLINE

Nema Manual Circuit Breaker Schematic Symbol READ ONLINE Nema Manual Circuit Breaker Schematic Symbol READ ONLINE If you are searching for a ebook Nema manual circuit breaker schematic symbol in pdf format, in that case you come on to loyal website. We presented

More information

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Solar Power Switchgear & Energy Storage Renewable Energy Systems 7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

SECTION ELECTRIC DISTRIBUTION

SECTION ELECTRIC DISTRIBUTION SECTION 16400 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions and other Division

More information

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Quick selector reference guide. Motor Control Center Aftermarket Buckets Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Selection and application guide

Selection and application guide Selection and application guide Integrated Power Systems Switchboards www.usa.siemens.com/switchboards Integrated Power Systems Switchboards Contents General Product Information 2-3 General Layout Information

More information

smissline Description

smissline Description Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group

More information

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray Product LINE Guide Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray Voltage Isolation Power Factor Correction

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Sensorless Vector Drives

Sensorless Vector Drives STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:

More information

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts Part #: EPSW-3PH-60-EB Page: 1 The EPSW-3PH-60-EB Three Phase Explosion Proof Switch by Larson Electronics is a

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

CWM_N NEMA Rated Contactors

CWM_N NEMA Rated Contactors Motors Automation Energy Transmission & Distribution Coatings CWM_N NEMA contactors have been a mainstay in the industrial marketplace in the US for decades. NEMA contactors were known for being robust

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r Generac offers more options for transfer switches than any other manufacturer. The LTS switch is designed to allow for the most efficient

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

REVISIONS App PC. App Sud. App Thom TC 2014/03/25 /9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

ches UL File No. E101598

ches UL File No. E101598 Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16410 Enclosed Switches and Circuit Breakers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information