FlexPoint UPS System. Technical Manual. Residential & MDU Applications. FlexPoint FP1230, FlexPoint FP1230F Power Supply Models
|
|
- Eleanor Shaw
- 5 years ago
- Views:
Transcription
1 TM FlexPoint UPS System Residential & MDU Applications Technical Manual FlexPoint FP30, FlexPoint FP30F Power Supply Models Effective: September 007 Alpha Technologies
2 Power Alpha Technologies
3 FlexPoint FP30 FlexPoint FP30F Technical Manual B-00, Rev. A Effective Date: September 007 Copyright 007 Alpha Technologies, Inc. member of The Group TM NOTE: Photographs contained in this manual are for illustrative purposes only. These photographs may not match your installation. NOTE: Operator is cautioned to review the drawings and illustrations contained in this manual before proceeding. If there are questions regarding the safe operation of this powering system, please contact Alpha Technologies or your nearest Alpha representative. NOTE: Alpha shall not be held liable for any damage or injury involving its enclosures, power supplies, generators, batteries, or other hardware if used or operated in any manner or subject to any condition not consistent with its intended purpose, or if installed or operated in an unapproved manner, or improperly maintained. To contact Alpha Technologies: Visit or For general product information and customer service (7 AM to 5 PM, Pacifi c Time), call , For complete technical support, call AM to 5 PM, Pacifi c Time or 4/7 emergency support To report errors in this document, send to: Techpubs@alpha.com 3
4 Table of Contents Safety Notes Introduction List of Terms Theory of Operation System Features Models and Options Items Included Installation Installation and Connection Installing the Battery....3 Installing the Safety Ground Shunt Operation Turn-Up Audible Alarms and Visual Indicators Battery Auxiliary Power Connection Operational Modes Normal Mode Back-Up Mode Emergency Use Charging Mode Example Discharge Profi le Specifi cations
5 Figures and Tables Fig -, Front View... 8 Fig -, Rear View... 8 Fig. -3, System Block Diagram... 8 Fig. -4, Items Included with Each Unit... 9 Fig. -, Unit Dimensions... 0 Fig. -, FP30 Input/Output Wiring... Fig. -3, FP30F Coax Connector... Fig. -4, FP30 Completed Wiring... Fig. -5, FP30F Output Cable... 0 Fig. -6, Battery and Wiring Harness... Fig. -7, Battery Compartment, FP30... Fig. -8, Battery Cable Connection... Fig. -9, Completed Installation... Fig. 3-, Controls and Indicators... 4 Table -, Input/Output Wiring... Table 3-, Audible Alarm and Visual Indicators... 5 Table 3-, Typical Battery Runtimes
6 Safety Notes Review the drawings and illustrations contained in this manual before proceeding. If there are any questions regarding the safe installation or operation of the system, contact Alpha Technologies or the nearest Alpha representative. Save this document for future reference. To reduce the risk of injury or death, and to ensure the continued safe operation of this product, the following symbols have been placed throughout this manual. Where these symbols appear, use extra care and attention. ATTENTION: The use of ATTENTION indicates specifi c regulatory/code requirements that may affect the placement of equipment and installation procedures. NOTE: A NOTE provides additional information to help complete a specifi c task or procedure. CAUTION! The use of CAUTION indicates safety information intended to PREVENT DAMAGE to material or equipment. WARNING! A WARNING presents safety information to PREVENT INJURY OR DEATH to the technician or user. 6
7 .0 Introduction. List of Terms Terms used in this document: FP30 FP30F FTTH ONT ONT-PPS PFS PON PSTN SOC SFU:ONT UPS FlexPoint 30 Series Indoor UPS FlexPoint 30 Series Indoor UPS with Type-F Coaxial connector Fiber To The Home/House Optical Network Termination ONT Primary Power Supply Product Functional Specifi cation Passive Optical Network Public Switched Telephone Network State of Charge, i.e. fully charged 3.6V = 00% SOC, a battery at 0.5V = 0% C Single Family Unit Optical Network Terminal; for this document ONT Uninterruptible Power Supply NOTE: The FlexPoint 30F power supply utilizes a Type-F Coaxial connector and cable for the output connection to the ONT. In all other respects it is identical to the FlexPoint FP30 power supply.. Theory of Operation The FlexPoint unit is an optical network terminal (ONT) power supply providing 30W of Vdc primary and standby power. A customer-provided 0Vac or 30Vac, 50/60Hz power outlet provides primary power to the input of the FlexPoint unit. The AC voltage is then converted to a usable Vdc output. The power supply is to be installed near an AC power outlet. Backup power and batteries are user friendly with features including, but not limited to, long life, ease of replacement, purchase, installation, and disposal. Power status is provided to the customer via audible alarms, visual indicators, and electrically to the service operator via PacketCable alarms (not available on the FlexPoint FP30F). The interface between the FP30 and the SFU ONT is a dedicated 7-conductor cable (sold separately). The cable includes two 6-gauge stranded conductors supplying power to the load, and fi ve 4-gauge solid conductors for signaling to the SFU ONT. The FlexPoint 30F power supply utilizes a Type-F Coaxial connector and cable for the output connection to the SFU ONT. Upon loss of AC service, the duration of standby power is determined by one 7.Ah, or optional Ah battery installed in the unit. If necessary, the customer can connect an auxiliary battery backup power supply specifi cally a battery providing additional standby runtime. During a prolonged AC outage the unit monitors remaining battery capacity. When 5% of the battery capacity remains, the Vdc supply to the ONT will be interrupted while the unit enters a sleep mode, conserving the remaining capacity for emergency calls. Interruption of the Vdc supply to the ONT will continue until the AC Mains is restored or the customer initiates the Battery Emergency Use mode by pressing the Emergency Use button on the face plate. The unit supports two grounding schemes. ONTs located outdoors, typically have a #6 ground wire connection to a ground rod, while ONTs located indoors may not have access to a reliable low resistance safety ground connection. For outdoor ONTs, an ungrounded, fl oating DC return would be used. For indoor ONT installations without access to a reliable ground connection, a supplied ground shunt, when installed, ties the ONT safety ground to the AC ground prong. 7
8 .0 Introduction, continued.3 System Features A robust power system which provides 30W of Vdc primary and standby power for FTTx activity Easy customer replaceable hot swappable 7.Ah or optional Ah battery Emergency battery reserve for greater E9 availability Battery management system engineered to provide optimum service life and runtime Local visual and audible status indicators Remote alarm interface Fig. -, Front View Fig. -, Rear View FlexPoint FP30 Hybrid cable (Model # FTTH-CBL) Five 4AWG conductors (4 alarms + return) Two 6AWG Conductors (+/-) FlexPoint FP30F Coaxial cable with Type-F connector ONT 0Vac or 40Vac Up to 8, (.4 meters) FP30 FP30F Vdc UPS Network Area Customer Area FP30: Up to 50 (5 meters) FP30F: Up to 5 (~.5 meters) Fig. -3, System Block Diagram 8
9 .0 Introduction, continued.4 Models and Options The FlexPoint 30 is available in four models, and optional equipment includes three models of batteries from which to choose, a battery cover, a battery heater kit option for cold-weather installations, an interconnect cable, and a cable for auxiliary power applications. Models Description FP30-0A 0Vac US Domestic 3-Conductor Power Cord (NEMA 5-5) FP30-0B 30Vac 3-Conductor Schuko Input Power Cord FP30-0C 30Vac 3-Conductor United Kingdom Input Power Cord FP30-0D 30Vac 3-Conductor Australia/New Zealand Input Power Cord FP30F-0A 0Vac US Domestic 3-Conductor Power Cord (NEMA 5-5) Supporting Options AX-STDBAT-7 AX-LONGBAT-7 AX-STDBAT- FP30-CVR FP30-HK FTTH-CBL AUX-CBL Battery 7.AH AGM, -year Warranty Battery 7.AH AGM, 3-year Warranty Battery AH AGM, -year Warranty, (Requires FP30-CVR) FlexPoint 30 AH Battery Cover with Strap, (required with Ah battery) FlexPoint 30 Heater Kit ONT Hook-up Cable, x6awg and 5x4AWG, CMX UL listed Cable, Auxiliary Power plug 3m Long.5 Items Included Verify the following items are included wth each unit. 3 4 a b c 5 Fig. -4, Items included with each unit FlexPoint unit Hardware Kit a b c Cable ties 7-pin connector Jumper for safety ground shunt Quick Start Guide FlexPoint 30: Alpha P/N B0 FlexFlexPoint 30F: Alpha P/N B Line cord Battery wiring harness 9
10 .0 Installation CAUTION!. Installation and Connection Observe wiring harness polarity. Improperly connecting these wires can result in non-operation of the unit, cause equipment damage, and void the warranty.. Unpack and inspect the unit.. The unit is designed for use in a sheltered environment protected from rain and snow with a maximum ambient temperature of 46 C. Install the unit near an AC outlet. 3. Remove battery compartment door by pressing tab and opening door. 4. Determine the necessary cable length to provide appropriate service loops between the unit, the ONT, and the outlet. Plug the line cord into the receptacle on the back of the unit and secure with a wire tie. DO NOT plug the unit into an AC outlet until the last step of the installation procedure. 5. Mount to the wall with # fasteners or equivalent, using the keyholes for easy mounting. For applications (with 7.Ah battery only) with higher seismic requirements, use the round holes in the back of the unit for direct fastening to a stud or other structural feature..00"/5mm Ø.380" 9.7mm Ø.50" 6.35mm.5" 63.5mm 3.0" 76mm 7.8" 98mm "Keyhole" slots for easy mounting Mounting holes for # hardware or equivalent.4" 6mm.3" 33mm 8.7"/mm 3.0" 76mm Center of Gravity (with battery installed) Fig. -, Unit Dimensions (in/mm), FP30 as viewed from back 0
11 .0 Installation, continued. Installation and Connection, continued 6. For the FlexPoint 30 model only: Cut and strip cable leads and attach to the 7- position connector, verifying correct conductor to pin alignment. See Table Plug the 7-conductor cable from the ONT into the 7-position connector and secure to strain relief with cable tie. See Figure -4. 7a. For the FlexPoint FP30F model only: Connect the outout coaxial cable to the connector and secure to strain relief with cable tie. See Figure -5. Installation tip: Pre-bend the cable before connecting to the circuit board. This will prevent stress on the circuit board caused by contact between the closed door of the unit and the coax cable Header Pin Auxiliary Vdc input #6AWG to ONT (pins, ) #4AWG to ONT (pins 3-7) Pin Connection Wire Gauge Pos (+) 6AWG Neg (-) 6AWG 3 Signal Return 4AWG 4 AC Fail 4AWG 5 REPLACE BATT 4AWG 6 BATT MISSING 4AWG 7 BATT LOW 4AWG Auxiliary Vdc input Vdc output connection Fig. -, FP30 Input/Output Wiring Table -, Input/Output Wiring Fig. -3, FP30F Coax Cable Connection Cable Tie 3 3 Front View Rear View AUX-CBL, Cable, Auxiliary Power Plug 3m Long FTTH-CBL, ONT hook-up cable, x6awg and 5x4AWG, CMX UL listed AUX-CBL, Cable, Auxiliary Power Plug (3m in length) Output Coax cable 3 AC line cord (secured by cable tie to strain relief) Fig.-4, FP30 Completed Wiring Fig.-5, FP30F Output Cables
12 .0 Installation, continued NOTE:. Installing the Battery. Connect the battery wiring harness (supplied) to the battery terminals (Fig. -6).. Connect the harness to the -pin connector (3) in the battery module (Fig. -7, -8). 3. Install the charged battery in the cradle as shown in (Fig. -9). The locking tab (4) secures it in place. The Battery LED will light at this time, and with the output cable connected, the unit will supply power to the load. The unit will not yet be on unless Battery Emergency Use button is pushed. 4. Resecure the battery compartment door. Keyed + Connector 3 Fig. -6, Battery and Wiring Harness Fig. -7, Battery Compartment, FP30 4 Fig. -8, Battery Cable Connection Fig. -9, Completed Installation
13 .0 Installation, continued NOTE:.3 Installing the Safety Ground Shunt The unit can provide a safety ground to ONTs located indoors where a suitable ground connection is not available. Installing the supplied jumper ties the Vdc return to the AC ground prong. Safety ground shunt must be installed prior to powering up the system.. Remove this tab. Expose these pins 3. Install jumper 3
14 3.0 Operation 3. Turn-Up. Plug the unit into AC Power.. The system LED () should light. Additional LEDs on the front panel of the FP30 indicate the state of the system. Their functions are: VISUAL STATUS INDICATORS 3 4 System (GREEN): The system indicator LED is on when power is available at the output. Input power could be derived from AC input or battery. Battery (GREEN): While the battery is discharging, the battery indicator LED will illuminate continuously until LED voltage reaches.7vdc; blinks when voltage drops below.7vdc. Replace Battery (RED): Battery replacement required (can indicate that the battery is missing). Auxiliary Power Source (GREEN): Indicates that an external power source with adequate voltage is connected to the FP30; blinks when providing power. BUTTONS 5 6 Silence Alarm: Press and hold button for approximately second to silence the audible alarm for 4 hours. Silence Alarm is acknowledged by a single chirp. Re-activate alarm circuit by pressing button again, which is acknowledged by two chirps. Battery Emergency Use: To restart the system, the Battery Emergency Use button is pressed (and held) for at least 0.5s Fig. 3-, Controls and Indicators 3. Verify the unit is functioning properly by unplugging it. After approximately 0 seconds the alarm should briefl y sound. After Amp-minute of discharge, the battery status LED () will light; after 5 Amp-minutes of discharge, the unit will activate the network alarm. 4. Re-plug the unit into an AC power outlet. The battery status LED () will go out. The unit is ready to be placed into service. 4
15 3.0 Operation, continued 3. Audible Alarms and Visual Indicators The table below details the audible alarms and visual indicators of the FP30. Condition Status LED Audible Alarm Status Connector Description NORMAL System LED (GREEN) N/A Pins 4, 5, 6, 7 pulled down to Pin 3 (SIGNAL RTN) Condition normal; AC powers load, charges battery. ON BATTERY Battery LED (GREEN) () s beep on loss of AC Pin 4 in open collector state Input fails; battery powers load. LOW BATTERY Battery LED (GREEN) blinking When AC is available, audible and status connector alarms are suppressed. When AC fails, beep every 5s. Pin 7 in open collector state When battery capacity is < 5%, unit triggers alarm, or when the Battery Emergency Use button is pressed. REPLACE BATT RED LED steady beeps, every 5 minutes Pin 5 in open collector state Every 80 days, the unit will automatically initiate a battery test. The test lasts approx. 60 min., and headend is notifi ed if battery replacement is needed. BATT MISSING RED LED steady beeps every 5 minutes Pin 6 in open collector state. Approximately 0s after battery removal, system initiates battery detection routine. Battery detection runs every 5s when fl oat charging. Upon verifi cation, alarm tripped. Auxiliary Power Source Connected AUX AUX LED connection point (GREEN) solid N/A N/A When the auxiliary power source is measured to be at least.5vdc at the input, the indicator (green LED) will be lit. The indicator will remain lit until the voltage is measured to be less the 0.5Vdc Auxiliary Providing Power AUX AUX LED (GREEN) blinks N/A N/A Indicates an external power source with adequate voltage is connected to the FP30/ FP30F. 3.3 Battery Table 3-, Audible Alarms and Visual Indicators Battery construction varies signifi cantly between manufacturers. Alpha Technologies recommends the use of qualifi ed batteries only. Part Description AX-STDBAT-7 AX-LONGBAT-7 AX-STDBAT- FP30-CVR Battery 7.Ah AGM, -year Warranty Battery 7.Ah AGM, 3-year Warranty Battery Ah AGM, -year Warranty FlexPoint 30 Ah battery cover with strap Battery: 5 C Constant Wattage Performance for 7.Ah (Final Voltage.75VPC) Discharge Time 90 min hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 9 hr 0 hr hr 0 hr Discharge Wattage Battery: 5 C Constant Wattage Performance for Ah (Final Voltage.75VPC) Discharge Time 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 9 hr 0 hr hr 0 hr Discharge Wattage Table 3-, Typical Battery Runtimes 3.4 Auxiliary Power Connection The unit has a connection point for customer-supplied auxiliary power source DC input voltage. The auxiliary power source supplies power to load (ONT) if the internal battery capacity is totally depleted after the Emergency Battery button is activated. 5
16 3.0 Operation, continued 3.5 Operational Modes 3.5. Normal Mode This mode is defi ned as a state where the load is being supplied from AC input, and the battery is fl oating, charging or in the process of being tested. When the unit is initially powered-up, or whenever the input supply has been restored after an outage, the unit operates in a charge mode. Once the battery voltage has reached the full charge voltage the unit switches to fl oat mode. If the input voltage is less than the minimum AC input, the system switches to operating in back-up mode. After approximately 80 days of operation, the battery is tested to determine whether it has adequate capacity. It is tested when the following conditions are met:. The system is operating in fl oat mode. The battery is fully charged If the battery is not fully charged, or the system is not operating in fl oat mode when the test becomes due, the test is postponed until those conditions are met. If the AC input is lost, or the unit is overloaded during the battery test, it will be aborted and indefi nitely postponed until conditions are valid. Once a battery test has been successfully executed, another test will be scheduled to occur in 80 days, without regard to the test results Back-Up Mode The load is being supplied from the battery while the battery voltage is greater than.5vdc, which is approximately 5% of the state of charge. When the battery falls below this point it is disconnected Emergency Use Battery Emergency Use mode occurs after the back-up mode has fi nished, which the user initiates by pressing Battery Emergency Use button. During this mode the battery will be allowed to discharge until its voltage is 0.5Vdc, which is 0% state of charge. At this time the system will shutdown unless an auxiliary power source is available. The operator should be aware of the following: Reserve time with 0W load at 5 C is approximately 30 minutes. Capacity reserved for emergency use is approximately 5% Charging Mode Float charge maintains the battery at 00% capacity. If the battery is required to support operation, charging ceases. When primary power is restored, battery charging resumes and continues until one of the following occurs: Battery has reached 00% of capacity. Charging is reduced to fl oat charge level. Normal charge current is approximately 700mA. When the current falls below 700 ma, the mode changes to fl oat. In the event the current does not reduce, the software triggers the mode change. Another power failure occurs requiring battery support. Charging ceases until primary power is restored. Additional power is required by the ONT. Power is diverted from the battery charger and sent to the ONT. When demand for additional power ceases, normal battery charging resumes. 6 The battery is depleted. No special action is required to restore normal operation once primary power is restored.
17 3.0 Operation, continued 3.5 Operational Modes, continued Example Discharge Profile The following is graphical representation of an assumed load profi le with load shedding (video followed by data). Load shedding schedules vary by service operator. The time between back-up operation and emergency use operation is indeterminate. Actual times are dependant upon temperature, actual loading and the state of health of the standby battery. Load Power 30W 0W.5Vdc EOD 5% SOC remaining Battery disconnected due to low remaining capacity Battery Emergency Use button pressed 0.5Vdc EOD Battery completely discharged AUX if present 0W 5 0 minutes Back up operation Emergency Time 7
18 4.0 Specifications INPUT AC Input Voltage Input Frequency Surge protection Auxiliary Input Voltage OUTPUT Operational Output Power Output Voltage Output Power Loading Connection BATTERY Battery Type 0Vac or 30Vac Models 50/60Hz ANSI/IEEE Std. C6.4 to Category A, B, or C requirements, using a Ring Wave or Combination waveform, at a level of 6kV 0.5Vdc to 6.5Vdc 30W max. continuous (ONT load*) Vdc Nominal (Battery voltage upon loss of AC) Following GR-909 telephone lines in various states, e.g., ringing, off-hook, on-hook, data, and video operation requirements. FlexPoint FP30: Removable 7-position plug FlexPoint FP30F: Type-F coaxial connector 7.Ah/Ah (with optional Ah cover kit) PHYSICAL Housing Size (in/mm): 8.75W x 7.75H x 3.0D/W x 97H x 76D Weight (lb/kg):.3lb/0.59kg Battery 7.Ah (lb/kg): 5.7/.6 Battery Ah (lb/kg): 8.4/3.8 VISUAL STATUS INDICATORS System: Battery: Replace Battery: Auxiliary Power Source: Green LED = Power is available at the output (AC, battery) Green LED = Battery discharging to 5% SOC (main or auxiliary) Green LED Flashing = Main battery at less than 5% SOC Red LED = Battery not present or failed self test Green LED = Valid auxiliary power source connected. Flashing indicates AUX prodiving power AUDIBLE STATUS INDICATORS Loss of Input Power: Low Battery Replace Battery: BUTTONS Silence Alarm Battery Emergency Use Single, one second beep (non-supressable) Single 0.5s beep every 5 seconds at 5% SOC Double beep every 5 minutes Suppresses the audible alarm for 4 hours Accesses reserve battery capacity AGENCY COMPLIANCE System FCC part 5 Class B, CSA-NRTL\C (CSA60950), CE, RoHS to EU 00/95/EC, Seismic zone 4 rated per GR-63. ENVIRONMENT Storage Temperature -40 C to +46 C (-40 F to +5 F) Operating Temperature Without heater: -0 C to +46 C (-4 F to +5 F) Note: Operating temperatures based on AX-LONGBAT-7 With heater: -30 C to +46 C (- F to +5 F) Humidity 5 to 95% Elevation Operation (max.) 0 to 0,000ft (0 to 3,000m) derate C per,000ft (305m) above 6,000ft (830m) Elevation Storage (max.) 50,000ft (5,000m) Battery Storage -0 C to +40 C (-4 F to +04 F) (six months max. storage duration at 5 C without a recharge) WARRANTY FlexPoint 30 Battery: 3 years repair or replace -year or 3-year models 8
19
20 Power Alpha Technologies Alpha Technologies 3767 Alpha Way Bellingham, WA 986 USA Tel: Fax: Web: Alpha Technologies Ltd McConnell Court Burnaby, BC V5A 3N7 CANADA Tel: Fax: Alpha Technologies Europe Ltd. Twyford House Thorley Bishop s Stortford Hertfordshire CM 7PA UNITED KINGDOM Tel: Fax: Alpha Technologies GmbH Hansastrasse 8 D-96 Schwabach GERMANY Tel: Fax: Alphatec, Ltd P.O. Box Limassol CYPRUS Tel: Fax: AlphaTek ooo Khokhlovskiy Pereulok 6 Stroenie, Offi ce Moscow RUSSIA Tel: Fax: Alphatec Baltics S. Konarskio G.49 Vilnius 009 LITHUANIA Tel: Fax: Alpha Technologies 9, Impasse Sans Souci 940 Clamart FRANCE Tel: Fax: Due to continuing product improvements, Alpha reserves the right to change specifi cations without notice. Copyright 007 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies B-00, Rev. A
FlexPoint TM. Series Power Supplies. Technical Manual FlexPoint 1215 / 1232 / 1250 Series Indoor Power Supplies Effective: August, 2015
FlexPoint TM Series Power Supplies Technical Manual FlexPoint 1215 / 1232 / 1250 Series Indoor Power Supplies Effective: August, 2015 Safety Notes Review the drawings and illustrations contained in this
More informationFlexPoint TM. Series UPS. Technical Manual FlexPoint 1208-F / 1232-D / 1250-D Series Indoor UPS Effective: September, 2015
FlexPoint TM Series UPS Technical Manual FlexPoint 1208-F / 1232-D / 1250-D Series Indoor UPS Effective: September, 2015 Safety Notes Review the drawings and illustrations contained in this manual before
More informationXM2-HP and XM2 CableUPS
and CableUPS Featuring the intelligent inverter module Total Power Solutions International Markets Reliability, Intelligence, Sustainability, Efficiency and CableUPS Industry leading highest efficiency
More informationTechnical Manual MPS48-7F/T. Alpha Technologies
TM Technical Manual MPS48-7F/T Effective: January 2008 Alpha Technologies Power Alpha Technologies MPS48-7F/T Technical Manual 021-511-B0-004, Rev. D Effective Date: January 2008 Copyright 2008 Alpha Technologies,
More informationAlphaCell SMU. Technical Manual. AlphaCell SMU. Effective: January Alpha Technologies
AlphaCell SMU Technical Manual AlphaCell SMU Effective: January 2007 Alpha Technologies Power Alpha Technologies AlphaCell SMU Technical Manual, Rev. A Effective Date: January, 2007 Copyright 2007 Alpha
More informationSMU-F. AlphaCell TM. Technical Manual. Valve Regulated Lead Acid Battery. AlphaCell SMU-F Valve Regulated Lead Acid Battery Effective: February 2007
AlphaCell TM SMU-F Valve Regulated Lead Acid Battery Technical Manual AlphaCell SMU-F Valve Regulated Lead Acid Battery Effective: February 2007 Alpha Technologies AlphaCell SMU-F Valve Regulated Lead
More informationSMU-F Valve Regulated Lead Acid Battery
AlphaCell TM SMU-F Valve Regulated Lead Acid Battery Installation and Operation Manual AlphaCell TM SMU-F Valve Regulated Lead Acid Battery Effective: December 2009 Alpha Technologies Power Alpha Technologies
More informationFlexPoint AX: Residential and MDU UPS System for NID/NIU/ONTS. Installation Manual Effective: April 2016
FlexPoint AX: Residential and MDU UPS System for NID/NIU/ONTS Installation Manual Effective: April 2016 Safety Notes Alpha considers customer safety and satisfaction its most important priority. To reduce
More informationUninterruptible Power Supply
Uninterruptible Power Supply (DUPS-1232) Main Features Up to 32W Output, under 38W for 10 minutes. User-friendly interface - Dry Contact Communication. Wide input voltage range - 90~264Vac. Wall Mount
More information3000VA 120/208/230VAC
User s Manual English Smart-UPS 2200VA 120/230VAC 3000VA 120/208/230VAC 2U Rack Mount Uninterruptible Power Supply 990-1352 12/02 Introduction The APC Uninterruptible Power Supply (UPS) is designed to
More informationFiber Backhaul Enclosure
Fiber Backhaul Enclosure Fiber Backhaul Enclosure (FBE) Installation Manual Effective: July 2009 Alpha Technologies Power Alpha Technologies Fiber Backhaul Enclosure Installation Manual 021-081-B0-001,
More informationNickel Cadmium Clear Case
Nickel Cadmium Clear Case Pocket Plate Battery Technical Manual Nickel Cadmium Clear Case Battery Effective: February 2007 Alpha Technologies Power Alpha Technologies Nickel Cadmium Clear Case Effective
More informationBack-UPS CS Back-UPS CS 350
Back-UPS CS Back-UPS CS 350 APC Back-UPS CS, 210 Watts / 350 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB Includes: CD with software, Cord management straps, USB cable, User Manual Standard
More informationUser Manual Back-UPS BX650CI-MS 230 Vac with AVR
User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety
More informationPowerware Vdc Extended Battery Cabinet User s Guide.
Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital
More informationInstallation and Operation Manual Back-UPS BX1100CI-CN
Installation and Operation Manual Back-UPS BX1100CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or
More informationBack-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software
Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software APC's Back-UPS ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power
More informationUninterruptible Power Systems
Sola S4K2U Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power
More informationInstallation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount
Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before
More informationThe 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.
1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL
More informationInstallation and Operation Back-UPS BX550CI-CN
Installation and Operation Back-UPS BX550CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there
More informationUser Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software
User Manual Thank you for purchasing the Defender 650/1200/1600. It is designed to provide safe and reliable power protection to your precious electronics equipment. Before you start using the product,
More informationSola/Hevi-Duty S3K Series Mini-Tower UPS
Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical
More informationUser Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply
More informationAccuPower AQU126B Installation Instructions
Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead
More informationLINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL
LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention
More informationInstallation and Operation Manual Back-UPS BR800/1100CI-IN
Installation and Operation Manual Back-UPS BR800/1100CI-IN Safety and General Information There are no serviceable parts in the Back-UPS. Do not attempt to open or repair the Back-UPS as this will void
More informationUser Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V
User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, oate, service or maintain
More informationInstallation and Operations Manual
Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com
More informationDIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual
DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided
More informationn Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES
n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES TABLE OF CONTENTS 1. Introduction...1 1.1 The Alpha Redundant Control Unit (RCU)... 1 1.2 A Tour
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More informationUninterruptible Power Supply
AC/DC Din Rail UPS System Single Phase Input, Single Phase Output Uninterruptible Power Supply 600VA UPS System AC/DC Din Rail Mount Line Interactive (PWM): 600VA User Manual M1201_Din_Rail_AC-DC_600VA_Manual
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible
More informationBack-UPS 650 VA 230 V with AVR (BX650CI-ZA)
Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
More informationUser Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationInstallation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA
Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
More informationSmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity
More informationHome Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual
Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual For safe and optimum performance, the Home Solar or Home Backup unit must be used properly.
More informationInstallation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount
Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationElmdene International Ltd
1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y
More informationSola 3000 Guide Specifications
Sola 3000 Guide Specifications CSI 16610 - Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL
More informationAccuPower AQU128B Installation Instructions
Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU128B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead
More information02/15/01. Powerware User s Guide VA.
02/15/01 Powerware 3115 User s Guide 300-650 VA www.powerware.com Powerware is a registered trademark of Powerware Corporation. Copyright 1999 Powerware Corporation, Raleigh, NC. All rights reserved. No
More information3 Uninterruptible Power Systems
S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges
More informationAlpha Lomain Ni-Cd Pocket Plate Battery Technical Manual. Effective: July Alpha Technologies
Alpha Lomain Ni-Cd Pocket Plate Battery Technical Manual Effective: July 2009 Alpha Technologies Power Alpha Technologies Alpha Lomain Ni-Cd Pocket Plate Battery Technical Manual 745-680-B10-001, Rev.
More informationMatch 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.
Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
More informationDIN Rail UPS Model: DIN-UPS Installation/Operation Manual
DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information
More informationInstallation Instructions & Users Manual
Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL
More informationLiebert PowerSure PSI UPS
Liebert UPS GUIDE SPECIFICATIONS 1000VA to 3000VA Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical and mechanical characteristics and
More informationInstallation Instructions
AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in
More informationUser Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information
User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation
More informationLimousin II User Manual
Limousin II User Manual 600VA Uninterruptible Power Supply Single Phase Input, Single Phase Output M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc SAVE THESE SAFETY INSTRUCTIONS 1. This manual contains
More informationUSER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA
USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.
More informationUninterruptible Power Supplies
SDU Series, Direct Current Uninterruptible Power Supply (DC UPS) System The SDU DIN Rail DC UPS is an advanced uninterruptible power system that combines an industry leading design with a wide operational
More informationSolar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5
More informationInstallation and Operation Manual Back-UPS BR1000-CH
Installation and Operation Manual Back-UPS BR1000-CH Complete, sign and return the Quality Assurance card or register the product online at www.apc.com. Safety This unit is intended for indoor use only.
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact
More informationAllen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply
Allen-Bradley User Manual for 3000/5000 VA UPS 1609-P3000N 1609-P3000H 1609-P3000A 1609-P5000E 3000 VA 120 VAC 3000 VA 208 VAC 3000 VA 230 VAC 5000 VA 208/230 VAC Tower/Rack-Mount 3U Uninterruptible Power
More informationInformer Compact Series
IMPORTANT SAFETY INSTRUCTIONS Informer Compact Series LINE-INTERACTIVE SINEWAVE UPS Uninterruptible Power System WARNING : (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions.
More informationSEAUPS-III Uninterruptible Power Conditioning System. System Manual
SEAUPS-III Uninterruptible Power Conditioning System System Manual N9246 Hwy 80 South, Suite 7, Necedah, WI 54646 Tel: 608-565-5877 Fax: 608-565-5879 Email: sales@lpc-ups.com Website: www.lpc-ups.com BILS-10012
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationGeneral Precautions. Personnel Precautions
USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only
More informationEclipse Plus VA UPS and Surge Suppressor User s Manual
Eclipse Plus 250 250VA UPS and Surge Suppressor User s Manual Compact UPS/Surge Suppressor for Home Office or Small Office Use www.mgeups.com Notes Contents Thank You!.....................................................
More information800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL
U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
More informationOperating Instructions
FUSE 028028 Operating Instructions Monarch 9876 and 9878 Mobile Work Station (MWS ) TC987xOI Rev. AC 12/15 2007 Avery Dennison Corp. All rights reserved. Each product and program carries a respective
More informationPower Inverter. User s Manual. Diamond Series CPD1200EILCD
Power Inverter Diamond Series CPD1200EILCD User s Manual 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements
More informationBC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL
BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT
More informationPOWERWARE User s Guide VA.
POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
More information27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2
1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:
More informationSmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation
More information3 Uninterruptible Power Systems
3 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line
More informationSmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation
More information7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL
7 Stage Automatic Smart Battery Charger Desulphuration& Maintainer (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1
More informationGES-202TLP Traffic Light System Installation Manual
GES-202TLP Traffic Light System Installation Manual M1603_TLP_Installation_Manual V1.0 2012-06-12 IMPORTANT EMERGENCY SHUTDOWN PROCEDURE ON THE INSIDE OF REAR COVER NOTE: The instructions contained in
More information2 Uninterruptible Power Systems
2 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line
More information3 Uninterruptible Power Systems
3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential
More informationIMPORTANT SAFEGUARDS
INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,
More informationAllen-Bradley 1609-D600N
User Manual Bulletin 1609 Uninterruptible Power Supply Catalog Numbers 1609-D and 1609-B Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical
More informationmiconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12
miconverter 18-Module Rack-Mount Power Chassis User Manual Page 12 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 General and Copyright Notice This publication is protected by
More informationApplication Engineering
Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the
More informationUsers Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:
More informationUser Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply 990-1194D 03/2012 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
More informationFiber Optic Illuminator. Model 21AC Model 21DC
Operation Manual Fiber Optic Illuminator Model 21AC Model 21DC Warning This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may
More informationOwner s Manual. PowerVerterDC-to-AC Inverter
Owner s Manual PowerVerterDC-to-AC Inverter Model: PV700HF Input V DC Output 0V, 60Hz AC Reliable AC Power Wherever You Need It Congratulations! You've purchased a high-quality Inverter designed to function
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More information18VDC ESB6 Series Cordless Screwdrivers Operation Manual
18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before
More informationMM-AVR UPS Series User s Manual
MM-AVR UPS Series User s Manual TABLE OF CONTENTS Safety Instructions... 2 Description... 2 Determining Power Requirements... 3 Hardware Installation Guide... 3 Battery Replacement Instructions... 4 LED
More informationUser Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER
User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection
More informationBRAVER UPS. (Uninterruptible Power System) User s Manual
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationUninterruptible Power Systems. SDU DC Series
Uninterruptible Power Systems SDU DC Series Instruction Manual While every precaution has been taken to ensure accuracy and completeness in this manual, SolaHD assumes no responsibility, and disclaims
More informationLiebert PSA VA. Installer/User Guide
Liebert PSA4 1000 1500 VA Installer/User Guide Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this manual to see if the
More informationUninterruptible Power Supplies
S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time
More information750W PowerVerter RV Inverter/Charger with Hardwire Input/Output
750W PowerVerter RV Inverter/Charger with Hardwire Input/Output MODEL NUMBER: RV750ULHW Highlights 12V DC or 120V AC input; 120V AC output (hardwired) 750 watts continuous, 1125 watts OverPower and 1500
More informationUsers Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com
More informationEMIU 720W Mini Inverter
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using
More informationGV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.
GV-4 Manual Solar Charge Controller with Maximum Power Point Tracking For models: GV-4-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded http://genasun.com Genasun Inc. 1035 Cambridge st. Suite 16B Cambridge,
More information