Technical Section: Miniature Circuit Breakers
|
|
- Hilda Shields
- 5 years ago
- Views:
Transcription
1 MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products Products comply to local and international standards (SANS, VC, IEC, etc).. DC Voltage Rating Please refer to CBI catalogues / leaflets for DC ratings. 4. For reverse connection Contact CBI for details. 5. Module Width CBI s MCB module widths are: mm and 26 mm dual mounting - (Escutcheon height 57 mm). mm, 8 mm and 27 mm in din-rail mounting (Escutcheon height 45 mm), Suffix D. 6. Special Breakers For all breakers manufactured to non-standard requirements, prices will be by quotation only 7. Standard Current Ratings Ampere ratings as indicated are standard. Non-standard ratings can be provided Prices on request (POR). 8. Switch Disconnectors All switch disconnectors must be backed up by a suitable short circuit protection device (SCPD), having the same or lower current rating and the same interrupting capacity as the switch disconnector, unless otherwise stated. Contact CBI for availability of 4 Pole switch disconnector units. 9. Motor Starting Please refer to Page 95 or CBI catalogue. Technical Section: Miniature Circuit Breakers 0. Time Delay Curves Curve No. Time Delay Instantaneous (short circuit) Non Tripping Current Tripping Current Long High 0 20 x In.05 x In.0 x In 2 Medium Medium 5 0 x In.05 x In.0 x In Short Low 5 x In.05 x In.0 x In 2, (LL) Medium 5 % Trip Point (Load Limiting).05 x In.5 x In 9 Long Medium 7 2 x In.05 x In.0 x In B Short Low 5 x In. x In.45 x In C Medium Medium 5 0 x In. x In.45 x In D Long High 0 20 x In. x In.45 x In OP (AC+DC) Very Short Low 5 x In.05 x In.0 x In U2 (DC) Medium Medium 6 x In.05 x In.0 x In KM Medium Medium 6 2 x In.00 x In. x In Note: Other curves available on request. Page 92
2 MCCBs and Accessories Data. 000 V Rating For 000 V rating, please consult CBI. (Switch disconnectors not available) 2. Adjustable Current Ratings Technical Section: Moulded Case Circuit Breakers From the FD range upwards, some breakers are fitted with adjustable magnetic trips. The suffix V/E types also have adjustable overload trips. E (electronic) types down to 50 % of nominal rating and suffix V (mechanical) types down to 75 % of nominal rating.. Calibration CBI thermal breakers are calibrated at 40 C, unless otherwise stated. Derating for higher temperature environment to be done in accordance with derating curves. 4. Reverse Connection Contact CBI for details. Units indicated line / load should not be reverse connected. 5. Special Breakers Prices for all breakers made by CBI to meet non-standard rating requirements of customer will be by quotation only. 6. Standard Current Ratings Ampere ratings indicated are standard. Non-standard can be provided, on application at a surcharge of up to 20 % of the next standard rating price, depending on quantity, product type and acceptance by CBI. 7. Switch Disconnector Fault Ratings The fault current ratings of CBI switch disconnectors which are fitted with shunt trips and external tripping devices are the same as those of the corresponding circuit breakers. Additional of interface barriers is mandatory. 8. Terminations Consult CBI Catalogues for details. 9. Transient Inrush and Close Co-ordination Protection Higher transient motor starting current associated with some high efficiency motors have created nuisance tripping problems. Consult CBI when in doubt. 0. DC Interrrupting Capacity Refer to CBI DC Catalogue for details.. Motor Starting In addition to cable protection functions, the CBI circuit breakers are designed for induction motor starting and protection duties. These breakers are particularly suited to direct-on-line starting applications for standard type motors in conjunction with a contactor overload combination or as a stand-alone unit. For complete details, refer to the Motor Starting and Protection Application Guide and Circuit breaker Selection Guide for DOL Motor Starting.. Warranty Claims Products may only be returned to CBI for warranty claims if all conditions under Section 7, Limitation of Liability, of CBI s General Terms and Conditions of Sale have been met (copy available upon request). Page 9
3 MCB Dimensions MCB Dimensions Product Height (A) Width (B) Depth (C) Escutcheon (D) QA - () QA - 2() QA - () () () () () (26) (26) (26) (26) (27)-D 97, (27)-D 97, (27)-D 97, (27)-D 97, (27)-D 97, (27)-D 97, (27)-D 97, (27)-D 97, A/C - D QA7 A/C , A/C ,8 57 SM5A SM6A Note: All measurements are in mm. Technical Section: MCB Dimensions Page 94
4 Technical Section: Motor Starting Guide: V MOTOR SIZE (kw) Notes: SINGLE PHASE VOLTAGE THREE PHASE VOLTAGE 20 V AC 400 V AC 5 ka 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* A* 0 A* 0 A* 5 A* 40 A* 45 A* 50 A* 60 A* 70 A* 80 A* 00 A* 0 ka 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* A* 0 A* 0 A* 5 A* 40 A* 45 A* 50 A* 60 A* 70 A* 80 A* 00 A* 5 ka A* 2 A* 2 A* 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* 20 A* 20 A* 20 A* A* 0 A* 5 A* 45 A* 60 A* 70 A* 80 A* 00 A* 0 ka A* 2 A* 2 A* 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* 20 A* 20 A* 20 A* A* 0 A* 5 A* 45 A* 60 A* 70 A* 80 A* 00 A* 5 ka G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 2 A G5D 2 A G5D(40 A G5D 40 A G5D 50 A G5D 6 A G5D 80 A G5D 00 A G5D 00 A G5D A G5D A F5D 75 A F5D 2 A F5D 0 A / FD 0 A KD 50 A KD 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM (750 A) ACB2000CM(900) ka 5 ka Note: * = External Overload Protection Required. ** = Locked Rotor Protection Only. GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 20 A GD 20 A GD 20 A GD 20 A GD 2 A GD 2 A GD 40 A GD 40 A GD 50 A GD 6 A GD 80 A GD 00 A GD 00 A GD A GD A FD 75 A FD 2 A FD 0 A / FD 0 A KD 50 A KD 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750A) ACB2000CM (900 A) G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 40 A G5D 40 A G5D 50 A G5D 6 A G5D 80 A G5D 00 A G5D 00 A G5D A G5D A F5D 75 A FD 2 A F5D 0 A / F5D0 A K5D 50 A K5D 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750 A) ACB2000CM(900 A) ) All information in this table is for reference and selection purposes only, and only direct line (DOL) starting. 2) Breaker selection is based on 4-pole three phase squirrel cage motors and certain deviations may be encountered for different motor manufacturers. ) Circuit breaker settings are based on rated motor current multiplied by,6 to prevent starting current from exceeding the instantaneous pick-up current of the circuit breaker. 4) For complete details refer to the Circuit Breaker Selection Guide for DOL Motor Starting. These are adjustable breakers and the current in ( ) is the ampere value that these breakers must be set at. 65 ka Curve Circuit Breakers Only. F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (20 A) F65DV 6- (20 A) F65DV 6- (20 A) F65DV 6- (20 A) F65DV -40 (2 A) F65DV -40 (2 A) F65DV -40 (40 A) F65DV -40 (40 A) F65DV 40-6 (50 A) F65DV 40-6 (6 A) F65DV 80-/6-00 (80 A) F65DV 80-/6-00 (00 A) F65DV 80-/6-00 (00 A) F65DV 80- ( A) F65DV 80- ( A) F65DV 60-0 (75 A) F65DV 60-0 (2 A) F65DV 0 A / K65DE 0 A) K65D (50 A) K65D (400 A) K70D (500 A) K70D00-60 (600 A) L70DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750 A) ACB2000CM (900 A) Page 95
5 DOL: Contactor - Overload - MCCB Selection Note: Customer to confirm motor FLC on site and adapt where necessary Motor Rating 400 V FLC Contactor Rating OL Relay Setting MCCB Rating Cable PH Kw HP AC A Type MCM AC A Type OR Range A A Size mm 2 5,5 7,5, CC8 8 CMT2 9 to A G7D 20 2,5 7,5 0 5,2 CC8 8 CMT2 2 to 8 A G7D 40 2,5 5 2,7 CC40 40 CMT2 8 to A G7D , CC40 40 CMT2 22 to 2 A G7D ,5 6 CC40 40 CMT2 28 to 40 A G7D CC50 50 CMT6 4 to 50 A G7D CC65 65 CMT6 45 to 65 A G7D CC85 85 CMT95 54 to 75 A CC85 85 CMT95 70 to 95 A CC00 00 CMT95 80 to 00 A CC50 50 CMT50 0 to 50 A K50D CC85 85 CMT2 20 to 85 A K50D CC2 2 CMT2 60 to 240 A K50D CC2 2 CMT to 0 A L65D CC0 0 CMT to 400 A L65D CC CMT to 400 A L65D CC60 60 CMT to 600 A L65D Motor Rating 500 V FLC Contactor Rating OL Relay Setting MCCB Rating Cable PH Kw HP AC A Type MCM AC A Type OR Range A A Size mm 2 5,5 7,5 9 CC8 CMT2 7 to 0 A G7D 6,5 7,5 0 2, CC8 CMT2 9 to A G7D 20 2,5 5 7,4 CC40 2 CMT2 6 to 22 A G7D 40 2, ,4 CC40 2 CMT2 8 to A G7D ,5 28,9 CC40 2 CMT2 24 to6 A G7D CC50 4 CMT6 24 to 6 A G7D CC65 60 CMT6 4 to50 A G7D CC85 75 CMT95 45 to 65 A G7D CC85 75 CMT95 54 to 75 A G7D CC00 85 CMT50 6 to 85 A G7D CC50 00 CMT2 85 to A CC85 85 CMT2 20 to 85 A CC85 80 CMT50 20 to85 A K50D CC2 200 CMT to 240 A K50D CC0 280 CMT to0 A K50D CC CMT to 400 A K50D CC CMT to 600 A L65D Technical Section: Motor Starting Page 96
6 Note: Customer to confirm motor FLC on site and adapt where necessary Technical Section: Motor Starting Page 97
7 DOL Starting (Full Load) R S T MCCB MCM TOR FUSE PB-OFF PB-ON TOR MCM M Conditions. The load shall be an Induction Motor with phase and 4 Poles. 2. Overload relay setting range is selected according to the full load current of the motor.. Cross-section area of the cable is within the value that is connectable to the motor starter. 4. Circuit Breaker (MCCB) is for cable protection. The breaking capacity of the MCCB should be reviewed according to site conditions. R S T Star Delta Starting MCCB FUSE PB-OFF MCM TOR X PB-ON MCM : TOR TR U V W M MCD MCD MCY X Y Z MCM MCY MCD TR MCY Technical Section: Motor Starting Conditions. The load shall be a squirrel cage motor with phase and 4 Poles. 2. Overload relay setting range is selected according to the full load current of the motor.. When the Thermal Overload Relay (TOR) is placed in the area shown. the setting range should be divided by (0,58) 4 Cross-section area of the cable is within the value that is connectable to the motor starter. 5. Thermal Circuit Breaker (MCCB) is for cable protection. The breaking capacity of the MCCB should be reviewed according to site conditions. 6. Thermal Overload Relay (TOR) mounting.* - Separately mountable with an optional mounting unit - Directly mountable when placed in the area shown in the dotted line Note: * Contact CBI for availability Page 98
8 Terminations G G4B X Technical Section: Moulded Case Circuit Breakers G4B G4 JSO / JS L20B / L40B N50D / N70D X G4B G4B KD / K5D JS/FD K50D X X2 Notes: Refer to product specific pages for actual terminal types - It might not be available as separate items if supplied as standard. For relevant current carrying capacities, please refer to relevant products. MCCB Terminal Bolt Sizes: JS - M8 L20 / L40B - M2 G5 / D - M8 G5D - M8 F5 / D - M8 F5D - M8 K / 5D - M2 L5 / 50D - M2 MB - M2 N85D - M2 MCCB Standard Range G7D - M8 - M8 K50D - M0 L65D - M2 N65D - M2 Page 99 MCCB Advanced Range G50D - M8 F50D - M8 F85D - M8 F50D - M8 K65D - M0 K85D - M0 K50D - M0 L65D - M2 L00D - M2 N50D - M0 x 2 N70D - M0 x 2 N50D - M0 x 2
9 THIS IS A SERIES CONNECTED (CASCADING) SYSTEM REPLACEMENT OF THE CIRCUIT BREAKERS OTHER THAN THOSE OF IDENTICAL TYPES SHOULD BE REFERRED TO THE CIRCUIT BREAKER MANUFACTURER Cascading Tables Note: Any current limiting by the cables should be taken into account. The Cascading Table is applied in practice as follows:. Determine the maximum prospective short circuit fault current level at the point of installation of the upstream breaker in the cascade. 2. Moving from the left side towards the right side of the cascading table, in the top row, select an upstream breaker whose breaking capacity rating is equal to or greater than determined by (.) above.. Determine the prospective short circuit current at the installation point of the downstream breaker, taking into account only the current limiting effect of any cable that is connected between the upstream and downstream breakers. Any current limiting by the upstream breaker should be ignored for this purpose. 4. From the first column on the left of the cascading table, select the row that represents a short circuit current that is equal to or higher than this latter short circuit current. 5. The downstream breaker suitable for the cascading application will then be found at the intersection of the row from (2) above, and the column from (4) above. Due to constant research and development, CBI reserves the right to make changes, modifications and extensions to these cascading tables without prior notice. No substitute of any alternative products is allowed. Technical Section: Cascading Care must be taken in replacing older product versions or obsolete ranges. Page 00
10 low voltage Cascading Table No. Technical Section: Cascading Tables Cascading Table (CBI MCCB s) Type G7D 5 - A 50-0 A K50D A L65D A No of Poles Fault Level ka Downstream ka / / 0 / / 20 5,,, / / 0 / BUSBAR RATING ka RMS Global Range Based Page 0
11 Cascading Table No. 2 80/45V Specific let-through energy curves 8 0 N50DEV600 5 Technical Section: Cascading Tables Protective Co-ordination Cascading 80/45 System Voltage Main: Advanced MCCB range Branch: Global Standard & Advanced Range G50D F50DEV F50D F50DEV F85DV K65DEV L65DEV L00DV K50D K50DEV N70DEV Capacity (ka rms) Main breaker Rated breaking Branch Breaker G7D K50D L65D F50DEV F85DV K50DEV L65DEV L00DV 00 L50DEV 50 N50DEV 50 N50DEV N70DEV 70 Maximum Let-through l²t (A²s) N50DEV000 L50D K50D F50D G50D Available Short Circuit Current (karms) Page 0
12 Cascading Table No. 2 K65D K5D KD CASCADING TABLE (CBI MCCBs and MCBs) UPSTREAM CIRCUIT BREAKERS TYPE No. OF POLES FAULT LEVEL ka AMP RATING BUSBAR RATING ka RMS G5D / F5D F65DV 5 65 GD / FD G5D / F5D L65D G5D / F5D G5D / F5D 5 0 G5D / F5D 0 G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D PROSPECTIVE DOWNSTREAM FAULT LEVEL ka (RMS) G5D / F5D G5D / F5D G5D / F5D G5D / F5D TYPE MOUNTING TYPE ESCUTCHEON, mm NOTES: 57 Mini / DIN / = -(), -(8), -(26) 45 DIN = -(8), -(26) ONLY, = Single pole circuit break ers,, = Single, double or triple pole circuit break ers F5D CAN CASCADE WITH ANY FD UPSTREAM BREAKER UP TO THE MAXIMUM FAULT LEVEL ka OF THE UPSTREAM BREAKER Technical Section: Cascading Tables Page 02
DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationParamount HRC Cartridge
Paramount HRC Cartridge Eaton MEM HRC fuselinks are manufactured to exacting standards using precision assembly methods and undergo rigorous quality checking before dispatch including resistance testing
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationMiniature & Moulded Case
Miniature & Moulded Case MCB OPERATION MAGNETIC OPERATION The short time protection (typically less than 1 second after energising) of the MCB is defined as the magnetic operation. 1 2 3 THERMAL OPERATION
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationADS7 AC Contactor Starters
ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationSentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification
543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication
More informationStarting of Induction Motors
1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding
More informationLow Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
More informationACW Molded-Case Circuit Breaker UL 489 Listed
Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.
More informationShort-circuit current limiter S800-SCL-SR
Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationMotor Starting Solutions Open Type Version, in Kit Form
Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationTerasaki (Europe) Ltd
Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland U.K. From head office at our 7,00 square metre facility, Terasaki Europe controls an International
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More informationGlobal Range Standard MCCB Fixed 3P (Thermal-Magnetic) No. of Interphase Barriers
G37D F37D K50D L65D N65D MB and Accessories Global Range Standard MB Fixed 3P (Thermal-Magnetic) 525 / 415 V 500 V 550 V G37D 3 G1 37 25 25 2 15, 20, 30, 40, 50, 60 RR2 213.00 G37D 3 G1 37 25 25 2 75,
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationGeneral data 5/37. Overview
General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available
More informationNEW SERIES OF ETIBREAK EB2 IN VIEW OF SELECTIVITY
NEW SERIES OF ETIBREAK EB2 IN VIEW OF SELECTIVITY WHAT IS SELECTIVITY? Selectivity in mean of protective devices is also called by other terms as discrimination or coordination of protective devices. To
More informationFeatures. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12
GLOBAL RANGE Global Range Thermal Contactors Contactors Contactor Product Comparison Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications
More informationDirect On Line (DOL) Motor Starter. Direct Online Motor Starter
Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationMiniature Circuit-Breakers (MCBs)
Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationMOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.
MOLDED CASE CIRCUIT BREAKER BASICS David Castor, P.E. History of MCCBs 1904 - Cutter Manufacturing Co., Philadelphia, produces circuit breakers. They called it the Inverse Time Element breaker, or I-T-E
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationUPDATED APRIL Motor Protection Concepts and Type 2 Co-ordination Charts
UPDATED APRIL 07 Motor Protection Concepts and Co-ordination Charts About us Switchgear Factory, Navi Mumbai Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The
More informationStarting Combinations
Main Catalogue Starting Combinations Motor Nominal Powers and Currents The currents given below concern standard, 1 500 r.p.m. 50 Hz, three-phase cage motors. These values are for your information and
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationThe University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:
More informationSelective Coordination
Circuit Breaker Curves The following curve illustrates a typical thermal magnetic molded case circuit breaker curve with an overload region and an instantaneous trip region (two instantaneous trip settings
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationMoDPlus Din Distribution Boards
MoDPlus Din Distribution Boards Introduction MoDPlus DIN Distribution Panel Board System MoDPlus Din type Distribution Board System has been designed and developed locally, incorporating features and benefits
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationTechnical Information
Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors
More informationABB Softstarter Benefits Charnchanok Thongprad
ABB Softstarter Benefits Charnchanok Thongprad tomation Technology Products AB Control - 1 - - Why Softstarters? Benefits for the Electrical network Reduces voltage drops on networks Minimizes starting
More informationProduct index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationSelective main circuit breakers S 750 series Technical Data
Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.
More informationInnovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual
Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationQF(13) - Series Miniature Circuit Breakers
DIN Mount 1 pole DIN Mount 2 pole Dual Mount 3 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three, four
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationData sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427
Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This
More informationQF(19) - Series Miniature Circuit Breakers
Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole,
More informationGLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features
GLOBAL RANGE Contactors Overload Relays Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications Commercial Industrial Mining Features
More informationInstallation Manual for DC Injection Brake Units
Power Drive Services INJ Series DC brake modules PDS 11-30-100A Page 1 of 17 Issue 15 Contents. 1. Safety. 2. Installation. 3. Setting Up. 4. Wiring Diagrams. 5. Specifications. 6. Selection. 7. Timing
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationQF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)
QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Dual Mount 1 pole Dual Mount 2 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationProduct index. 4 - Manual motor protectors. Phone: Fax: Web: -
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationDevices for Branch Circuits and Feeders
Devices for Branch Circuits and Feeders Branch Circuit Overcurrent Protective Devices and s Fusible Solutions: When selecting fusible overcurrent protective devices, the type of fuse holder or switch is
More informationCascading & Discrimination
Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More information1492-CB 1492-GH 1492-GS
1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic
More informationProtectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.
Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,
More informationMAGNETIC MOTOR STARTERS
Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationSynergy EN product information
Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz
More informationS200 UL 489 Series. Miniature circuit breakers S200. Features. Description
UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationContactors and Overloads MC
Contactors and Overloads MC Up to 700A AC3 Up to 00A AC1 DIN rail mounting to 5A, 55kW Add on auxiliary contacts top or side mounted International approvals Designed to EN60971 Compact design for panel
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationL Frame - Series Moulded Case Circuit Breakers
Surface Mount 3 pole Surface Mount 3 pole Features Hydraulic-magnetic technology 100 % rating capacity; independent of ambient temperature Three poles Ratings up to 600 A AC (1500 A DC) Trip button for
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More informationAn electrical panel capable of evolving
An electrical panel capable of evolving Prisma TT Low voltage factory built assemblies Buildings Commercial & Industrial Make the most of your energy General For a dependable electrical installation Total
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationFile E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:
File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,
More informationBtdin RCBO 6000A up to 63A (2P)
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationMotor-protective circuit-breakers PKZ: now better than ever
Motor-protective circuit-breakers PKZ: now better than ever Motor-protective circuit-breakers PKZ from Moeller have long set the benchmark for quality. nd now, for inclusion in the xstart concept, these
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More information