SHENANDOAH VALLEY ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER

Size: px
Start display at page:

Download "SHENANDOAH VALLEY ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER"

Transcription

1 Page 1 of 5 APPLICABILITY SHENANDOAH VALLEY ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER Unless specifically excluded within this Schedule, all of the Cooperative's Terms and Conditions shall apply to net metering customers, including agricultural net metering customers. This Rider applies to any distribution customer in the Cooperative's service area that qualifies for and executes an agreement for net metering service or agricultural net metering service. "Net metering service" means providing retail electric service to a customer operating a renewable fuel generator and measuring the difference, over the net metering period, between electricity supplied to the customer from the Cooperative's distribution system and the electricity generated and fed back to the Cooperative's distribution system by the customer. A customer may qualify for this service by owning and operating, or contracting with other persons to own, operate, or both, a renewable fuel generator that (i) uses as its total fuel source sunlight, wind, falling wafer, sustainable biomass, energy from waste, wave motion, tides, or geothermal power; (ii) is located on his premises and is connected to the customer's wiring on the customer's side of its interconnection with the Cooperative; (iii) is interconnected and operated in parallel with an electric company's transmission and distribution facilities; and (iv) is primarily intended to offset part or all of the member/customer's own electricity requirements. "Agricultural net metering service" means, for the limited purpose of providing net metering service as defined above, aggregating into one account the load of multiple meters serving a single customer meeting the definition of "agricultural net metering customer" as defined in 20 VAC Agricultural net metering customers are included within the terms governing net metering customers in this Schedule unless stated otherwise, and are subject to additional provisions as indicated within the Schedule. For the purpose of agricultural net metering, "aggregating into one account the load of multiple meters" will be accomplished by adding all of the billing determinants (energy and coincident demand) from each meter and calculating the charges as if the totalized energy and demand had been measured by a single meter. For residential customers, the renewable fuel generator capacity may not exceed twenty (20) kilowatts alternating current, for non-residential customers, the renewable fuel generator capacity may not exceed one megawatt (1 MW) alternating current, and for eligible agricultural customer-generators, the renewable fuel generator capacity may not exceed five hundred (500) kilowatts alternating current. The interconnection shall be through a single meter or, as provided in 20 VAC , additional meters; or for an agricultural net metering customer, multiple meters of the utility that are located at separate but contiguous sites as defined in 20 VAC The total connected capacity of all Filed: January Effective: On and after January

2 Page 2 of 5 net metering and agricultural renewable fuel generators connected to the Cooperative shall not exceed 1.0% of the Cooperative's Virginia peak-load forecast for the previous year. In addition to the foregoing maximum renewable fuel generator size limitations, the maximum aggregate capacity of the renewable fuel generator(s) shall also be limited. The customer shall be allowed to install a generator(s) capable of generating up to the customer's previous 12 months of usage history (or an annualized estimate thereof made using existing utility methodologies) based upon the expected annual output of the generator(s), but not more. The Cooperative will work with the customer to ascertain a maximum capacity agreeable to both the Cooperative and the customer, with the primary determinant being the customer's historic or predicted annual consumption. Should the Cooperative and the customer be unable to agree, the customer may submit an infonnal complaint to the Commission Staff. The restriction on maximum generator capacity contained within this paragraph shall be applicable to those customers whose renewable fuel generator(s) are interconnected on and after July 1, 2015, and are subject to this Rider. The Cooperative will abide by the State Corporation Commission's Regulations Governing Net Energy Metering, 20 VAC etseq., as amended (the "Rules") in applying the provisions of this Rider. The Cooperative may require an applicant for agricultural net metering to provide documentation (such as, e.g., deeds, plats, or leases) or such other evidence satisfactory to the Cooperative to reasonably demonstrate that the meters the applicant desires to aggregate are (1) on the same or contiguous sites and (2) that the customer uses the affected sites for its agricultural business. If the Cooperative has an applicable time-of-use ("TOU") tariff, the following definitions shall apply. A TOU net metering customer is one electing to receive retail electricity supply service under a demand charge-based TOU tariff, if one is offered by the Cooperative. A TOU period is an interval of time over which the energy rate charged to a TOU customer does not change. A TOU Tier is all of those TOU periods given the same name, such as "on-peak" or "off-peak" or "critical peak." TOU Tier rates may vary. The TOU Tiers will be denominated on the Cooperative's TOU tariff. MONTHLY CHARGES The tariff for a net energy metering customer shall be that tariff under which the customer would be served if the customer were not a net energy metering customer (the customer's standard tariff), with the exception that TOU net metering is not permitted under an electricity supply seivice tariff having no demand charges. An agricultural net metering customer will be served on a rate schedule determined by the Cooperative to be available, applicable, and appropriate to the characteristics of the totalized load, as if the energy consmnption and demand had been measured by a single meter at a single location. If more than one rate schedule is available, applicable, and appropriate for the characteristics of the aggregated account, the customer will have the option to select the schedule on which the customer will be served. Filed: January 12, 2016 Effective: On and after January 12, 2016

3 Page 3 of 5 MINIMUM MONTHLY CHARGES For any billing period in which generation exceeds consumption, producing a billing period credit, the monthly charge shall be based only on the fixed charges of the customer's standard tariff, and any charges that may be applicable per: (i) an excess facilities agreement and, (ii) a Commission-approved standby charge. Fox net metering customers not utilizing a TOU tariff, the customer must pay only the nonusage sensitive charges for any billing period in which a billing period credit exists. Regarding TOU net metering customers, for whom excess generation is determined separately for each TOU Tier, the customer must pay only the demand charges and the nonusage sensitive charges in any billing period when there are credits in all tiers for that billing period. Billing period credits will be carried forward and applied to offset future consumption charges as provided in Rule 20 VAC OPTIONS FOR PURCHASE OF EXCESS ENERGY AND FOR PURCHASE OF RENEWABLE ENERGY CERTIFICATES ("RECS") If the Cooperative is also the energy service provider of the net metering customer, the Cooperative, upon written request of the net metering customer, shall enter into an agreement to purchase excess generation for the requested net metering periods at a price equal to the simple average of the Cooperative's hourly avoidable cost of energy, including fuel, based on the energy and energy-related charges of its primary wholesale power supplier for the net metering period, unless the Cooperative and the net metering customer mutually agree to a higher price or unless, after notice and opportunity for hearing, the commission establishes a different price or pricing methodology. A net metering customer shall receive no compensation for excess generation unless the net metering customer has entered into a power purchase agreement with the Cooperative. Net metering customers own the RECs associated with their renewable fuel generators. A net metering customer wishing to sell its RECs to the Cooperative may do so by exercising a one-time only option, at the time it executes the power purchase agreement with the Cooperative, to include a provision requiring the purchase by the supplier of all generated RECs over the duration of the power purchase agreement. Such sales shall be subject to reasonable metering and verification requirements as determined by the Cooperative. The rate payable for RECs shall be (i) determined by adherence to the.rules and (ii) reference to the "CR" component of Dominion Virginia Power's Rider G Tariff, as permitted under the Rules. NOTIFICATION REQUIREMENTS A prospective net metering customer shall give notice to the Cooperative of the proposed renewable fuel generator that the customer proposes to install, or to which the customer proposes to add capacity, including the proposed unit's generating capacity. The customer is encouraged to contact the Cooperative as soon as possible, ideally before entering into an agreement to purchase a renewable fuel generator, to ascertain the capacity limitations and other suitability requirements prior to proposing installation. The customer shall also Filed: January Effective: On and after January 12, 2016

4 Page 4 of 5 verify that the requirements for interconnection are met once the renewable fuel generator has been installed. The customer shall use the Commission-approved form (Form NMIN) for the purposes of making said notification and verification. An agricultural net metering customer who aggregates meters must notify the Cooperative within 30 days of any outage of the customer's generating facility and provide reasonable evidence of the customer's efforts to restore the generating facility to service in a timely manner. The Cooperative will use good faith to determine if the customer's plans to restore the facility to service are reasonably likely to restore the facility to seivice in a timely manner. If the Cooperative determines in its discretion that the customer is not making reasonable efforts to restore the facility in a timely manner, the Cooperative will suspend the customer's meter aggregation effective immediately. Upon suspension of meter aggregation due to an outage of the customer's generating facility, all usage during an outage, starting with the next full billing period after the billing period in which the outage began, will be billed at the standard rate schedules individually applicable to the previously aggregated meters. Meter aggregation will resume once the generation facility is operational. For purposes of this paragraph only, the phrase "timely manner" shall mean within a period of two calendar weeks, or longer should the Cooperative and the customer both agree, OPERATING REQUIREMENTS Prior to interconnecting the renewable fuel generator the net energy metering customer must comply with all requirements of the Regulations Governing Net Energy Metering, Title 20, Agency 5, Chapter 315, Virginia Administrative Code, pursuant to provision of Section of the Virginia Electric Utility Restructuring Act, as amended. These regulations specify insurance requirements, interconnection requirements, and govern the metering, billing and contract requirements between net energy metering customers, electric distribution companies, and energy service providers. All net energy metering customers shall have installed a lockable, load-breaking manual disconnect switch at a suitable location, approved by the Cooperative, that allows the Cooperative round-the-clock, unobstructed access to the switch and that can be easily located and accessed by the Cooperative. Unobstructed access to tire switch must be maintained at all times, at the customer's expense. NET METERING ADDITIONAL COST PROVISIONS ' Customers who take service (see "Monthly Charges," above) under a time-of-use tariff are responsible for all incremental metering costs associated with net metering. Any additional metering equipment associated with incremental metering to measure the total output of the renewable fuel generator for the purposes of receiving RECs, as reasonably determined by the Cooperative, shall be installed at the customer's expense unless otherwise negotiated between the customer and the Cooperative, Filed: January Effective: On and after January

5 Page 5 of 5 For an agricultural net metering customer, the meters at all locations from which usage is to be totalized into one account shall be capable of measuring demand determinants as specified in the rate schedule appropriate to the totalized load. The Cooperative will eitherexchange an existing meter with one capable of measuring the required demand determinants or use an approximate demand value based on consumption data. Any additional metering equipment resulting from the need to measure demand as a requirement of the rate schedule applicable to an agricultural net metering customer, as reasonably determined by the Cooperative, shall be installed at the customer's expense unless otherwise negotiated between the customer and the Cooperative. The customer's expenses as described above may be recovered from the customer by way of an excess facilities agreement. CONTACT INFORMATION If the prospective net energy metering customer has contracted with another person to own, operate, or both, the renewable fuel generator, the Cooperative must have detailed, current and accurate contact information for the owner, operator, or both, including without limitation, the name and title of one or more individuals responsible for the interconnection and operation of the generator, a telephone number, a physical sheet address other than a post office box, a fax number, and an address for each person or persons. The net energy metering customer shall immediately notify the electric distribution company of any changes in the ownership of, operational responsibility for, or contact information for the generator. CHARGES FOR SERVICES BY THE COOPERATIVE Inspection of static inverter-connected generators in excess of 10 kw - Inverter settings: $ Inspection of non-static inverter-connected generators - All protective equipment: $ TERMS OF SERVICE The contract term shall be the same as that under the customer's applicable service classification. A separate agreement with the customer is required for service provided under this Rider. Filed: January 12, 2016 Effective: On and after January 12, 2016

6 2016 SESSION INTRODUCED D 1 HOUSE BILL NO U 2 Offered January 13, Prefiled January 13, 2016 ^ 4 A BILL to amend and reenact of the Code of Virginia, relating to electric utilities; net energy 5 metering programs; energy balancing devices; study and report. 8 6 Patron Toscano 7 8 Committee Referral Pending ^ 9 1. reenacted as follows: Be it enacted by the General Assembly of Virginia: That of the Code of Virginia is amended and ^ a Net energy metering provisions. A. The Commission shall establish by regulation a program programs that affords eligible afford: I J hfj Eligible customer-generators the opportunity to participate in net energy meterings and a program, 15 te begin ne later than July 2014, for customers ef investor owned utilities and ne later than July Jrj Q , for customers ef electric cooperatives, te afford eligible; Eligible agricultural customer-generators the opportunity to participate in net energy metering, 18 which program shall begin no later than Jidy 1, 2014, for such customers of investor-owned utilities and 19 no later than July 1, 2015, for such customers of electric cooperatives; and Eligible energy balancing customers the opportunity to participate in net energy metering, which 21 program shall begin no later than July 1, 2017, for such customers of investor-owned utilities and no 22 later than July 1, 2018, for such customers of electric cooperatives, provided that the aggregate 23 capacity of energy balancing devices deployed by all eligible energy balancing customers in the 24 Commonwealth shall not exceed 25 megawatts The regulations may include, but need not be limited to, requirements for (i) retail sellers electric utilities; (ii) owners or operators of distribution or transmission facilities; (iii) providers ef default JT service; (tv) eligible customer-generators; fv) (iv) eligible agricultural customer-generators; (v) eligible energy balancing customers; or (vi) any combination of the foregoing, as the Commission determines 29 will facilitate the provision of net energy metering, provided that the Commission determines that such 30 requirements do not adversely affect the public interest B. For the purpose of this section: "Eligible agricultural customer-generator" means a customer that operates a renewable energy 33 generating facility as part of an agricultural business, which generating facility (i) uses as its sole energy 34 source solar power, wind power, or aerobic or anaerobic digester gas ; ; (ii) does not have an aggregate 35 generation capacity of more than 500 kilowatts^; (iii) is located on land owned or controlled by the 36 agricultural business^; (iv) is connected to the customer's wiring on the customer's side of its 37 interconnection with the distributor electric utility; (v) is interconnected and operated in parallel with an 38 electric company's utility's transmission and distribution facilities^; and (vi) is used primarily to provide 39 energy to metered accounts of the agricultural business. An eligible agricultural customer-generator may 40 be served by multiple meters that are located at separate but contiguous sites, such that the eligible 41 agricultural customer-generator may aggregate in a single account the electricity consumption and 42 generation measured by the meters, provided that the same utility serves all such meters. The aggregated load shall be served under the appropriate tariff. "Eligible customer-generator" means a customer that owns and operates, or contracts with other 45 persons to own, operate, or both, an electrical generating facility that (i) has a capacity of not more than kilowatts for residential customers and not more than one megawatt for nonresidential customers on an electrical generating facility placed in service after July 1, 2015; (ii) uses as its total source of fuel 48 renewable energy, as defined in ; (iii) is located on the customer's premises and is connected to 49 the customer's wiring on the customer's side of its interconnection with the distributor electric utility, 50 (iv) is interconnected and operated in parallel with an electric company's transmission and distribution 51 facilities; and (v) is intended primarily to offset all or part of the customer's own electricity 52 requirements. In addition to the electrical generating facility size limitations in clause (i), the capacity of 53 any generating facility installed under this section after July 1, 2015, shall not exceed the expected 54 annual energy consumption based on the previous 12 months of billing history or an annualized 55 calculation of billing history if 12 months of billing history is not available. 56 "Eligible energy balancing customer" means a commercial or indusbial customer that owns an 57 energy balancing device that is (i) located on the customer's premises, (ii) connected to the customer's 58 wiring on the customer's side of its interconnection with the elecbic utility, and (iii) interconnected and

7 HB of 4 59 operated in parallel with an electric utility's transmission and distribution facilities. A customer shall 60 not qualify as an eligible energy balancing customer unless (a) the operation of its energy balancing 61 device provides a service of value to the electric utility or regional transmission entity, including 62 spinning reserve, frequency regulation, distribution system support, reactive power, demand response, or 63 other electric grid services; (b) discharge from the energy balancing device to the electric grid meets all 64 requirements for safety, including anti-islanding, and power quality established pursuant to the IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems or SAE Standard J3072, or successor standards, approved by the Institute of Electrical and Electronics Engineers Standards Board or the Society of Automotive Engineers, as appropriate; (c) the electric 68 utility and the customer have entered into an agreement pursuant to which the electric utility undertakes 69 to credit the customer for electricity fed back to the electric grid by operation of the energy balancing 70 device as provided in subsection G; and (I) the aggregate net energy flows from the customer's energy 71 balancing device over any net metering period result in a net energy inflow to the customer's premises "Energy balancing device" means (i) a grid-integrated electric vehicle or (ii) an electric battery consisting of one or more electrochemical cells that convert stored chemical energy into electrical 74 energy, that are located at a commercial or industrial site, and that absorb ancl return energy to the 75 electric grid on either (a) a second-to-second response basis that provides frequency regulation or (b) a 76 longer-term daily response basis that stores excess energy from the electric grid during periods of 77 excess supply and then returns that energy to the electric grid during peak periods of demand "Grid-integrated electric vehicle" means a battery-run motor vehicle that has the ability for two-way power flow between the vehicle and the electric grid and the communications hardware and software that allow for the external control of battery charging and discharging by an electric utility, a regional transmission entity, or an aggregator. 82 "Net energy metering" means measuring the difference, over the net metering period, between (i) 83 electricity supplied to an eligible customer generator er eligible agricultural customer-generator a net 84 metering customer from the electric grid and (ii) the electricity generated and fed back to the electric 85 grid by the eligible customer generator er eligible agricultural customer generator net metering customer. 86 "Net metering customer" means any eligible customer-generator, eligible agricultural 87 customer-generator, or eligible energy balancing customer. 88 "Net metering customer's system" means (i) with regard to an eligible customer-generator or eligible 89 agricultural customer-generator, its electrical generating facility and appurtenant equipment and (ii) 90 with regard to an eligible energy balancing customer, its energy balancing device and appurtenant 91 equipment. 92 "Net metering period" means the 12-month period following the date of final interconnection of the eligible customer-generator's er eligible agricultural customer generator's net metering customer's system with an electric service provider, and each 12-month period thereafter. 95 "Regional transmission entity" means the regional transmission entity of which an electric utility is a 96 member pursuant to and C. The Commission's regulations shall ensure that (i) the metering equipment installed for net 98 metering shall be capable of measuring the flow of electricity in two directions and (ii) any eligible 99 customer generator net metering customer seeking to participate in net energy metering shall notify its 100 supplier electric distribution company and receive approval to interconnect prior to installation of an 101 electrical generating facility. The electric distribution company shall have 30 days from the date of 102 notification for residential facilities, and 60 days from the date of notification for nonresidential 103 facilities, to determine whether the interconnection requirements have been met. Such regulations shall 104 allocate fairly the cost of such equipment and any necessary interconnection. An eligible 105 customer generator's electrical generating Each net metering customer's system^ and each electrical 106 generating system ef an eligible agricultural customer generator, shall meet all applicable safety and 107 performance standards established by the National Electrical Code, the Institute of Electrical and 108 Electronics Engineers, the Society of Automotive Engineers, and accredited testing laboratories such as 109 Underwriters Laboratories. Beyond the requirements set forth in this section and to ensure public safety, 110 power quality, and reliability of the supplier's electric distribution system, an eligible customer generator 111 er eligible agricultural customer generator a net metering customer whose electrical generating system 112 meets those standards and rules shall bear all reasonable costs of equipment required for the 113 interconnection to the supplier's electric distribution system, including costs, if any, to (i) install 114 additional controls, (ii) perform or pay for additional tests, and (iii) purchase additional liability 115 insurance. 116 D. The Commission shall establish minimum requirements for contracts to be entered into by the 117 parties to net metering arrangements. Such requirements shall protect the eligible customer generator er 118 eligible agricultural customer generator net metering customer against discrimination by virtue of its 119 status as an eligible customer generator er eligible agricultural customer generator, a net metering 120 customer and permit customers that are served on time-of-use tariffs that have electricity supply demand

8 3 of charges contained within the electricity supply portion of the time-of-use tariffs to participate as an 122 eligible customer generator er eligible agricultural customer generator net metering customers. 123 Notwithstanding the cost allocation provisions of subsection C, eligible customer generators er eligible 124 agricultural customer generators net metering customers served on demand charge-based time-of-use 125 tariffs shall bear the incremental metering costs required to net meter such customers E. If electricity generated by an eligible customer-generator or eligible agricultural customer-generator over the net metering period exceeds the electricity consumed by the eligible customer-generator or 128 eligible agricultural customer-generator, the eligible customer-generator or eligible agricultural 129 customer-generator shall be compensated for the excess electricity if the entity contracting te receive 130 such electric energy electric utility and the eligible customer-generator or eligible agricultural 131 customer-generator enter into a power purchase agreement for such excess electricity. Upon the written request of the eligible customer-generator or eligible agricultural customer-generator, the supplier teat serves tee eligible customer generator er eligible agricultural customer generator electric utility shall 134 enter into a power purchase agreement with tee requesting eligible customer-generator or eligible 135 agricultural customer-generator that is consistent with tee minimum requirements for contracts 136 established by the Commission pursuant to subsection D. The power purchase agreement shall obligate 137 the supplier electric utility to purchase such excess electricity at tee rate teat is provided for such purchases in a net metering standard contract or tariff approved by the Commission, unless the parties agree to a higher rate. The eligible customer-generator or eligible agricultural customer-generator owns 140 any renewable energy certificates associated with its electrical generating facility; however, at the time 141 that the eligible customer-generator or eligible agricultural customer-generator enters into a power 142 purchase agreement with its supplier electric utility, tee eligible customer-generator or eligible 143 agricultural customer-generator shall have a one-time option to sell the renewable energy certificates 144 associated with such electrical generating facility to its supplier electric utility and be compensated at an 145 amount that is established by the Commission to reflect the value of such renewable energy certificates. 146 Nothing in this section shall prevent the eligible customer-generator or eligible agricultural customer-generator and the supplier electric utility from voluntarily entering into an agreement for the sale and purchase of excess electricity or renewable energy certificates at mutually-agreed upon prices if 149 the eligible customer-generator or eligible agricultural customer-generator does not exercise its option to 150 sell its renewable energy certificates to its supplier electric utility at Commission-approved prices at the 151 time that tee eligible customer-generator or eligible agricultural customer-generator enters into a power 152 purchase agreement with its supplier electric utility. All costs incurred by tee supplier electric utility to 153 purchase excess electricity and renewable energy certificates from eligible customer-generators or 154 eligible agricultural customer-generators shall be recoverable through its Renewable Energy Portfolio 155 Standard (RPS) rate adjustment clause, if the supplier electric utility has a Commission-approved RPS 156 plan. If not, then all costs shall be recoverable through the supplier's electric utility's fuel adjustment 157 clause. For purposes of this section subsection, "all costs" shall be defined as means the rates paid to the 158 eligible customer-generator or eligible agricultural customer-generator for the purchase of excess electricity and renewable energy certificates and any administrative costs incurred to manage the eligible customer-generator's or eligible agricultural customer-generator's power purchase arrangements. The net 161 metering standard contract or tariff shall be available to eligible customer-generators or eligible 162 agricultural customer-generators on a first-come, first-served basis in each electric distribution company's 163 Virginia service area until the rated generating capacity owned and operated by eligible 164 customer-generators or eligible agricultural customer-generators in the state reaches one percent of each 165 electric distribution company's adjusted Virginia peak-load forecast for the previous year, and shall 166 require the supplier electric utility to pay the eligible customer-generator or eligible agricultural 167 customer-generator for such excess electricity in a timely manner at a rate to be established by the Commission. F. Any residential eligible customer-generator or eligible agricultural customer-generator who owns 170 and operates, or contracts with other persons to own, operate, or both, an electrical generating facility 171 with a capacity that exceeds 10 kilowatts shall pay to its supplier electric utility, in addition to any other 172 charges authorized by law, a monthly standby charge. The amount of the standby charge and the terms 173 and conditions under which it is assessed shall be in accordance with a methodology developed by the 174 supplier electric utility and approved by the Commission. The Commission shall approve a supplier's an 175 electric utility's proposed standby charge methodology if it finds teat the standby charges collected from 176 all such eligible customer-generators and eligible agricultural customer-generators allow the supplier 177 electric utility to recover only the portion of tee supplier's electric utility's infrastructure costs that are 178 properly associated with serving such eligible customer-generators or eligible agricultural 179 customer-generators. Such an eligible customer-generator or eligible agricultural customer-generator shall 180 not be liable for a standby charge until the date specified in an order of the Commission approving its 181 supplier's electric utility's methodology.

9 HB of G. Notwithstanding the definition of net energy metering in subsection B, the aggregate net energy 183 flows from an eligible energy balancing customer's energy balancing device to the electric grid and 184 from the grid to the customer over any net metering period shall result in net energy to the eligible 185 energy balancing customer's premises. Therefore, the eligible energy balancing customer shall not be 186 compensated for excess electricity over the net metering period. However, over shorter time intervals, 187 the eligible energy balancing customer may return electric energy to the g'id. Over time intervals 188 shorter than the net metering period, the rate at which an eligible energy balancing customer shall be credited for electricity added to the grid from such customer's energy balancing device shall be the same as the rate charged to the eligible energy balancing customer for electricity provided by the 191 electric utility to the eligible energy balancing customer for such customer's consumption at its premises 192 pursuant to the applicable tariff. The requirements of subsection C shall apply to any energy balancing device deployed pursuant to this section. H. An aggregator is explicitly permitted to combine two or more eligible energy balancing customers and sell en erg' balancing services; those services may be sold to a regional transmission entity, under wholesale rules and rates as regulated by the Federal Energy Regulatory Commission, or those services 197 may be sold to an electric utility under rides and rates as regulated by the Commission That the State Corporation Commission shall conduct a study of the effectiveness of, and 199 benefits achieved from, the deployment of energy balancing devices pursuant to this act. The study 200 shall (i) address the extent to which energy balancing devices are deployed, (ii) analyze the benefits 201 to the electric grid that result from the deployment of energy balancing devices, and (iii) 202 determine whether the incentives for the deployment of energy balancing devices provided by the 203 provisions of this act are commensurate with the benefits provided by their deployment. The 204 Commission shall report its findings and any recommendations to the Governor and General Assembly by December 1, That the provisions of the first enactment of this act shall expire on July 1, 2019; however, any energy balancing device that commences operating prior to July 1, 2019, shall be permitted to continue operating pursuant to the provisions of this act for a period of 10 years following the 209 date the energy balancing device commenced operating.

RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER

RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER Page 1 of 5 ACCEPTED FOR RUHR RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER APPLICABILITY Unless specifically excluded within this Schedule, all of the Cooperative's Terms

More information

STATE CORPORATION COMMISSION DIVISION OF PUBLIC UTILITY REGULATION. May 22, 2018

STATE CORPORATION COMMISSION DIVISION OF PUBLIC UTILITY REGULATION. May 22, 2018 William F. Stephens Director (804) 371-9611 FAX (804)371-9350 PO Box 1197 Richmond, Virginia 23218-1197 DIVISION OF May 22, 2018 Mr. Eric M. Page Ecker Seamans Cherin & Mellott, LLC 919 East Main Street

More information

TERMS AND CONDITIONS XXV. NET METERING CUSTOMERS AND SMALL AGRICULTURAL GENERATORS

TERMS AND CONDITIONS XXV. NET METERING CUSTOMERS AND SMALL AGRICULTURAL GENERATORS A. Applicability and Availability 1. The terms Net Metering Service, Net Metering Customer, Agricultural Net Metering Customer, Small Agricultural Generator, Agricultural Business, Customer, Person(s),

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Demand Charge-based Time-of- Use Tariff, Net Metering Customer, Customer, Time-of-Use Customer, Time-of-Use Tier,

More information

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES 220 CMR 18.00: NET METERING Section 18.01: Purpose and Scope 18.02: Definitions 18.03: Net Metering Services 18.04: Calculation of Net Metering Credits 18.05: Allocation of Net Metering Credits 18.06:

More information

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM Sheet 1 FITCHBURG GAS AND ELECTRIC LIGHT COMPANY SCHEDULE NM Applicability The following tariff provisions shall be applicable to a Host Customer, as defined herein, that requests net metering services

More information

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM Sheet 1 FITCHBURG GAS AND ELECTRIC LIGHT COMPANY SCHEDULE NM Applicability The following tariff provisions shall be applicable to a Host Customer, as defined herein, that requests net metering services

More information

SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY

SERVICE CLASSIFICATION CEF COMMUNITY ENERGY FACILITY P.S.C. Del. No. 8 - Electric Original Leaf No. 95a SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY A Community Energy Facility (CEF) consists of one or more generators located in Company s service

More information

(2) Scope. 220 CMR applies to all Distribution Companies subject to the jurisdiction of the Department.

(2) Scope. 220 CMR applies to all Distribution Companies subject to the jurisdiction of the Department. D.P.U. 11-10-A 220 CMR 18.00: NET METERING Section 18.01: Purpose and Scope 18.02: Definitions 18.03: Net Metering Services 18.04: Calculation of Net Metering Credits 18.05: Allocation of Net Metering

More information

2lr1344 CF 2lr1396. Drafted by: Heide Typed by: Rita Stored 02/02/12 Proofread by Checked by By: Senator Pinsky A BILL ENTITLED

2lr1344 CF 2lr1396. Drafted by: Heide Typed by: Rita Stored 02/02/12 Proofread by Checked by By: Senator Pinsky A BILL ENTITLED C Bill No.: Requested: Committee: CF lr Drafted by: Heide Typed by: Rita Stored 0/0/ Proofread by Checked by By: Senator Pinsky A BILL ENTITLED AN ACT concerning Electricity Community Energy Generating

More information

Consumer Guidelines for Electric Power Generator Installation and Interconnection

Consumer Guidelines for Electric Power Generator Installation and Interconnection Consumer Guidelines for Electric Power Generator Installation and Interconnection Habersham EMC seeks to provide its members and patrons with the best electric service possible, and at the lowest cost

More information

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS. 25.211. Interconnection of On-Site Distributed Generation (DG). (a) (b) (c) Application. Unless the context indicates otherwise, this section and 25.212 of this title (relating to Technical Requirements

More information

Schedule SP SOLAR PURCHASE (Experimental)

Schedule SP SOLAR PURCHASE (Experimental) I. APPLICABILITY & AVAILABILITY This Schedule is available in conjunction with the Company s Solar Purchase Program ( Program ) and is applicable only where the Customer elects to receive Electricity Supply

More information

SCHEDULE 62 COGENERATION AND SMALL POWER PRODUCTION SCHEDULE - IDAHO

SCHEDULE 62 COGENERATION AND SMALL POWER PRODUCTION SCHEDULE - IDAHO First Revision Sheet 62 62 I.P.U.C. No. 28 Original Sheet 62 SCHEDULE 62 COGENERATION AND SMALL POWER PRODUCTION SCHEDULE - IDAHO AVAILABLE: In all the electric territory served by the Company in the State

More information

Senate Substitute for HOUSE BILL No. 2101

Senate Substitute for HOUSE BILL No. 2101 Senate Substitute for HOUSE BILL No. 2101 AN ACT concerning utilities; relating to renewable energy resources; amending K.S.A. 2013 Supp. 66-1,184, 66-1265, 66-1266, 66-1267 and 66-1271 and repealing the

More information

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING Third Revised Sheet 55a Cancels Second Revised Sheet 55a A. ELIGIBLE CUSTOMER-GENERATOR RULE NO. 17 NET ENERGY METERING Net energy metering is available to eligible customer-generators, defined as, permanent

More information

First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.

First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. First Revision of Sheet No. 135.1 P.S.C.U. No. 50 Canceling Original Sheet No. 135.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 135 STATE OF UTAH Net Metering Service Closed to Applications for

More information

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY Table of Contents Chapter 1. Purpose and scope. Pg 3 Chapter 2. Application

More information

City of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources

City of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources Ordinance No. 743 Exhibit A City of Washington, Kansas Electric Department Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources Page 1 of 7 1. INTRODUCTION The provisions of this

More information

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION SAMPLE ORDINANCE 3/5/2012 Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION Section 1: Applicable Service Territory Net metering and electrical system interconnection is available on a first-come,

More information

RIPUC No Cancelling RIPUC No Sheet 1 THE NARRAGANSETT ELECTRIC COMPANY NET METERING PROVISION

RIPUC No Cancelling RIPUC No Sheet 1 THE NARRAGANSETT ELECTRIC COMPANY NET METERING PROVISION THE NARRAGANSETT ELECTRIC COMPANY NET METERING PROVISION RIPUC No. 2178 Sheet 1 I. Definitions Commission shall mean the Rhode Island Public Utilities Commission. Community Remote Net Metering System shall

More information

MASSACHUSETTS ELECTRIC COMPANY NANTUCKET ELECTRIC COMPANY NET METERING PROVISION

MASSACHUSETTS ELECTRIC COMPANY NANTUCKET ELECTRIC COMPANY NET METERING PROVISION Sheet 1 of 28 Applicability The following tariff provisions shall be applicable to a Host Customer, as defined herein, that requests Net Metering services from the Distribution Company, with the exception

More information

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities New Ulm Public Utilities Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities INDEX Document Review and History... 2 Definitions... 3 Overview... 3 Application

More information

Thank you for your time and attention to this matter. Please feel free to contact me if you have any questions regarding the filing.

Thank you for your time and attention to this matter. Please feel free to contact me if you have any questions regarding the filing. Mary L. Cottrell, Secretary March 27, 2009 Page 1 Stacey M. Donnelly Counsel September 23, 2009 Mark D. Marini, Secretary Department of Public Utilities One South Station Boston, MA 02110 Re: D.P.U. 09-03

More information

Buy All Sell All Rider for Interconnection of Renewable Generation

Buy All Sell All Rider for Interconnection of Renewable Generation for Interconnection of Renewable Generation I. Availability Available to each Customer of Fayetteville Public Works Commission (PWC) that purchases retail electricity from PWC and that owns and operates

More information

City of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources

City of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources Ordinance No. Exhibit A ----------------------------------------- City of, Kansas Electric Department Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources -------------------------------------

More information

HOUSE BILL No Koch

HOUSE BILL No Koch Introduced Version HOUSE BILL No. 1320 DIGEST OF INTRODUCED BILL Citations Affected: IC 8-1-40; IC 36-7-5.3. Synopsis: Generation of electricity by distributed generation. Provides that the utility regulatory

More information

JACKSON ELECTRIC COOPERATIVE POLICY NO. 305

JACKSON ELECTRIC COOPERATIVE POLICY NO. 305 JACKSON ELECTRIC COOPERATIVE POLICY NO. 305 I. SUBJECT: Interconnected Distributed Generation (DG) II. OBJECTIVE: To provide guidelines and procedures for members/applicants and JEC personnel in DG systems.

More information

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH P.S.C.U. No. 50 Original Sheet No. 136.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH Transition Program for Customer Generators AVAILABILITY: At any point on the Company's interconnected

More information

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members 49.1 INTERCONNECTION OF AND SERVICE TO QUALIFYING FACILITIES UNDER Objective To provide for the interconnection of and service to a Qualifying Facility in keeping with the provisions of the Public Utility

More information

The Commonwealth of Massachusetts

The Commonwealth of Massachusetts The Commonwealth of Massachusetts DEPARTMENT OF PUBLIC UTILITIES D.P.U. 12-81-A January 18, 2013 Investigation by the Department of Public Utilities on its own Motion Commencing a Rulemaking pursuant to

More information

HOUSE BILL 801. (0lr2294) ENROLLED BILL Economic Matters/Finance

HOUSE BILL 801. (0lr2294) ENROLLED BILL Economic Matters/Finance C HOUSE BILL 0 ENROLLED BILL Economic Matters/Finance (0lr) Introduced by Delegates McHale, Hecht, Bartlett, Hammen, Hecht, and Krysiak Krysiak, Barkley, Beidle, Bobo, Bronrott, Carr, G. Clagett, Doory,

More information

White River Electric Association, Inc. Net Metering Information & Service Requirements

White River Electric Association, Inc. Net Metering Information & Service Requirements White River Electric Association, Inc. Net Metering Information & Service Requirements What is Net Metering? Net Metering is an electric policy and service for consumers who own and utilize renewable energy

More information

Montana-Dakota Utilities Co. A Division of MDU Resources Group, Inc. 400 N 4 th Street Bismarck, ND 58501

Montana-Dakota Utilities Co. A Division of MDU Resources Group, Inc. 400 N 4 th Street Bismarck, ND 58501 Original Sheet No. 72 Page 1 of 7 AVAILABILITY: Available to any customer that owns and operates a solar, wind or hydroelectric generating facility with a capacity of not more than 25 Kw that is located

More information

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program As part of our commitment to support renewable energy, Kissimmee Utility Authority

More information

H 7366 S T A T E O F R H O D E I S L A N D

H 7366 S T A T E O F R H O D E I S L A N D LC0000 01 -- H S T A T E O F R H O D E I S L A N D IN GENERAL ASSEMBLY JANUARY SESSION, A.D. 01 A N A C T RELATING TO PUBLIC UTILITIES AND CARRIERS - MUNICIPAL STREETLIGHT INVESTMENT ACT Introduced By:

More information

24. SOLAR INCENTIVE PROGRAM II

24. SOLAR INCENTIVE PROGRAM II 24. SOLAR INCENTIVE PROGRAM II A. General California Senate Bill 1 requires publicly owned utilities that sell electricity at the retail level, to adopt, implement, and fund a solar incentive program for

More information

Umatilla Electric Cooperative Net Metering Rules

Umatilla Electric Cooperative Net Metering Rules Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through

More information

Overview of S.L Competitive Energy Solutions for North Carolina

Overview of S.L Competitive Energy Solutions for North Carolina Overview of S.L. 2017-192 Competitive Energy Solutions for North Carolina JENNIFER MCGINNIS CHRIS SAUNDERS STAFF AT TORNEYS, LEGISLATIVE ANALYSIS DIVISION 1 Overview Product of extensive stakeholder process

More information

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM A. Application. The following tariff shall apply to members who: (1) take service under a rate within this electric service

More information

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings:

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings: Original Sheet No.34 Rider NEM 1) Definitions Certain words, when used in this Rider NEM shall be understood to have the following meanings: a) Baseline Annual Usage : i) The total of an Eligible Customer-Generator

More information

RIDER NM NET METERING

RIDER NM NET METERING d/b/a Ameren Illinois 5 th Revised Sheet No. 24 Electric Service Schedule Ill. C. C. No. 1 (Canceling 4 th Revised Sheet No. 24) PURPOSE * The purpose of this tariff is to establish an offering of net

More information

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program. Electric Tariff _2nd Revised Sheet No. 72 Filed with Iowa Utilities Board Cancels _1st Sheet No. _72 Cooperative is a member of Central Iowa Power Cooperative (CIPCO), a generation and transmission cooperative

More information

THE GENERAL ASSEMBLY OF PENNSYLVANIA HOUSE BILL

THE GENERAL ASSEMBLY OF PENNSYLVANIA HOUSE BILL PRINTER'S NO. THE GENERAL ASSEMBLY OF PENNSYLVANIA HOUSE BILL No. Session of 0 INTRODUCED BY QUINN, DONATUCCI, SCHLOSSBERG, D. MILLER, FREEMAN, STURLA, SCHWEYER, BARRAR AND SIMS, JANUARY, 0 REFERRED TO

More information

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE Page 1 of 7 AVAILABILITY Service under this rate shall apply to any Customer in the Cambridge service area who executes a Standby Service Agreement with the Company and who satisfies the following conditions:

More information

Springfield Utility Board Net Metering Policy Adopted on February 13, 2008 (Resolution 08-1)

Springfield Utility Board Net Metering Policy Adopted on February 13, 2008 (Resolution 08-1) Springfield Utility Board Net Metering Policy Adopted on February 13, 2008 (Resolution 08-1) 4-2-2 NET METERING. The objective of this net metering policy is to establish Springfield Utility Board (SUB)

More information

ROANOKE ELECTRIC COOPERATIVE RATE SCHEDULES

ROANOKE ELECTRIC COOPERATIVE RATE SCHEDULES ROANOKE ELECTRIC COOPERATIVE P. O. DRAWER 1326 AHOSKIE, NORTH CAROLINA 27910 RATE SCHEDULES EC 31 SUB. 44 APPROVED BY BOARD OF DIRECTORS: August 7, 2018 EFFECTIVE FOR BILLS RENDERED ON OR AFTER November

More information

A Bill Regular Session, 2015 HOUSE BILL 1004

A Bill Regular Session, 2015 HOUSE BILL 1004 Stricken language would be deleted from and underlined language would be added to present law. Act of the Regular Session 0 State of Arkansas 0th General Assembly As Engrossed: H// H// A Bill Regular Session,

More information

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board Policy Description: In an effort to ensure fair treatment of all of its customers,

More information

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A SUBJECT: Interconnection of and Service to Qualifying Facilities under Public Utility Regulatory Policies Act (PURPA) OBJECTIVE: To provide, through

More information

JEA Distributed Generation Policy Effective April 1, 2018

JEA Distributed Generation Policy Effective April 1, 2018 Summary This JEA Distributed Generation Policy is intended to facilitate generation from customer-owned renewable and non-renewable energy generation systems interconnecting to the JEA electric grid. The

More information

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No.

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No. P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No. 39 PURPOSE: The purpose of the Solar Subscription Pilot Rider (Program) is to provide a limited number of

More information

BC Hydro Rate Schedule 1289 Revision 1 Effective: April 20, 2018 Page 6-1

BC Hydro Rate Schedule 1289 Revision 1 Effective: April 20, 2018 Page 6-1 Page 6-1 6. OTHER RATE SCHEDULE 1289 NET METERING SERVICE Availability For any Residential Service Customer and for any General Service Customer who: 1. installs a Generating Facility to generate electricity

More information

216B.164 COGENERATION AND SMALL POWER PRODUCTION.

216B.164 COGENERATION AND SMALL POWER PRODUCTION. 116C.7792 SOLAR ENERGY INCENTIVE PROGRAM. (a)the utility subject to section 116C.779 shall operate a program to provide solar energy production incentives for solar energy systems of no more than a total

More information

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE Effective: April 2015 Billing Cycle AVAILABILITY: The E-27 Price Plan is subject

More information

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT This Net Metering and Interconnection Agreement ( Agreement ) is made and entered into as of this day of, 2018, by the City of Santa

More information

NET METERING. The terms set forth below shall be defined as follows, unless the context otherwise requires.

NET METERING. The terms set forth below shall be defined as follows, unless the context otherwise requires. Page 1 of 31 Applicability The following tariff provisions shall be applicable to a Host Customer, as defined herein, that requests Net Metering services from the Distribution Company, with the exception

More information

Net Energy Metering and Interconnections. Community Solar in the District of Columbia

Net Energy Metering and Interconnections. Community Solar in the District of Columbia Net Energy Metering and Interconnections Community Solar in the District of Columbia Presented by: Virginia Burginger August 4, 2016 1 Welcome Overview of Community Net Metering in the District of Columbia

More information

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined Application to Amend Net Metering Service under RS 1289 Revised RS 1289 Clean and Black-lined Rate Schedule 1289 Revision 1 Effective: April 20, 2018 Page 6-1 Clean 6. OTHER RATE SCHEDULE 1289 NET METERING

More information

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM A. Application. The following tariff shall apply to members who: (1) take service under a rate within this electric service

More information

78th OREGON LEGISLATIVE ASSEMBLY Regular Session. House Bill 4036

78th OREGON LEGISLATIVE ASSEMBLY Regular Session. House Bill 4036 th OREGON LEGISLATIVE ASSEMBLY--0 Regular Session House Bill 0 Introduced and printed pursuant to House Rule.00. Presession filed (at the request of House Interim Committee on Energy and Environment) SUMMARY

More information

SCHEDULE NO. ACG33 NET METERING SERVICE

SCHEDULE NO. ACG33 NET METERING SERVICE Approved by Decision No.: 75408 Effective: January 19, 2016 Applicability Applicable to "Net Metering Facility" as defined below, or applicable Arizona Corporation Commission ("Cmnn1ission") Decision,

More information

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility Processed Date Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility Customer s Printed Name Installation Street Address Account Number Please note: Columbia Water & Light

More information

SCHEDULE 6 RESIDENTIAL SERVICE ON-SITE GENERATION

SCHEDULE 6 RESIDENTIAL SERVICE ON-SITE GENERATION I.P.U.C. No. 29, Tariff No. 101 Original Sheet No. 6-1 PUBLIC UTILITIES COMMISSION AVAILABILITY Service under this schedule is available at points on the Company's interconnected system within the State

More information

Michigan Renewable Energy Case Study

Michigan Renewable Energy Case Study Michigan Renewable Energy Case Study NARUC ENERGY REGULATORY PARTNERSHIP WITH GEORGIAN NATIONAL ENERGY AND WATER SUPPLY REGULATORY COMMISSION TBILISI, GEORGIA JANUARY 27-31, 2014 GREG R. WHITE, COMMISSIONER

More information

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No.

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No. SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No. 137 NET METERING SERVICE APPLICABILITY This net energy-metering schedule is applicable to residential, small

More information

Louisiana Net Metering Service. Customer Information Package

Louisiana Net Metering Service. Customer Information Package Louisiana Net Metering Service Customer Information Package August 1, 2013 Net Metering - The means of measuring the difference between the electricity supplied by an electric utility and the electricity

More information

COMMUNITY SOLAR PROGRAM

COMMUNITY SOLAR PROGRAM Original Sheet No. D-22.00 COMMUNITY SOLAR PROGRAM The Cooperative's generation and transmission Cooperative ("G&T") has created a standing offer for 10 MW ofrenewable energy, produced by solar and wind

More information

Distributed Generation Interconnection Policy

Distributed Generation Interconnection Policy Distributed Generation Interconnection Policy 1 Introduction Carroll Electric Membership Corporation Distributed Generation Interconnection Policy Carroll Electric Membership Corporation (herein after

More information

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65 M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65 CLASS OF SERVICE: CUSTOMER GENERATING SYSTEMS OVER 20 KW RATE CGS 1 AVAILABILITY To customers owning generating

More information

ATTACHMENT 14 RESOLUTION NO. 5888(14) Supersedes Schedule NEM of Resolution No. 5592(09) Schedule NEM NET ENERGY METERING

ATTACHMENT 14 RESOLUTION NO. 5888(14) Supersedes Schedule NEM of Resolution No. 5592(09) Schedule NEM NET ENERGY METERING APPLICABILITY ATTACHMENT 14 RESOLUTION NO. 5888(14) Supersedes Schedule NEM of Resolution No. 5592(09) Schedule NEM NET ENERGY METERING This net metering schedule applies to residential and/or small commercial

More information

Southern California Edison Original Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Cal. PUC Sheet No.

Southern California Edison Original Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Cal. PUC Sheet No. Southern California Edison Original Cal. PUC Sheet No. 58584-E Schedule CRPP Sheet 1 APPLICABILITY This Schedule is applicable to Customer Participants, as defined below, who elect to participate in the

More information

Net Metering & Compensation Seminar

Net Metering & Compensation Seminar Net Metering & Compensation Seminar November 2, 2017 Eversource Energy Hadley, MA Changes Are Here Market Net Metering Credit was introduced: 60% Market equal to 60% of distribution, transition, transmission

More information

HydroGenerations PROGRAM HANDBOOK

HydroGenerations PROGRAM HANDBOOK HydroGenerations PROGRAM HANDBOOK TABLE OF CONTENTS Please ensure you are reading the most recent version of this handbook by visiting the NV Energy website, www.nvenergy.com/hydro. Contents HydroGenerations

More information

BC Hydro Rate Schedules Effective: August 1, 2015 Fourth Revision of Page 30

BC Hydro Rate Schedules Effective: August 1, 2015 Fourth Revision of Page 30 BC Hydro Effective: August 1, 2015 Fourth Revision of Page 30 SCHEDULE 1289- NET METERING SERVICE Availability: For any Residential Service Customer and for any General Service Customer who install a Generating

More information

Kansas Legislator Briefing Book 2009

Kansas Legislator Briefing Book 2009 Kansas Legislator Briefing Book 2009 Agriculture, Natural Resources, and Energy B-5 Net Metering Other reports available B-1 The Kansas Animal Health Department and Foreign Animal Diseases B-2 Water Litigation

More information

THE PUBLIC SERVICE COMMISSION OF MARYLAND

THE PUBLIC SERVICE COMMISSION OF MARYLAND THE PUBLIC SERVICE COMMISSION OF MARYLAND Report on the Status of Net Energy Metering In the State of Maryland Prepared for the General Assembly of Maryland Pursuant to 7-306(i) of the Public Utilities

More information

SCHEDULE 84 CUSTOMER ENERGY PRODUCTION NET METERING SERVICE

SCHEDULE 84 CUSTOMER ENERGY PRODUCTION NET METERING SERVICE Idaho Power Company Fourth Revised Sheet No. 84-1 I.P.U.C. No. 29, Tariff No. 101 Third Revised Sheet No. 84-1 AVAILABILITY Issued per Order No. 34046 June 1, 2018 Service under this schedule is available

More information

Noble County Rural Electric Membership Corporation

Noble County Rural Electric Membership Corporation Albion, Indiana Page 1 of 5 SCHEDULE NB-1 RESIDENTIAL NET BILLING I. AVAILABILITY This Net Billing Rate is available to any residential member in good standing of Noble REMC (Noble) who owns and operates

More information

Schedule No. NMR-405 NET METERING RIDER-405 APPLICABLE

Schedule No. NMR-405 NET METERING RIDER-405 APPLICABLE 6100 Neil Road, Reno, Nevada Original PUCN Sheet No.81D(3)(ab) APPLICABLE This Rider is applicable to purchases of excess energy from any Customer-generator taking service under any Rate Schedule 1) whose

More information

Net Metering in Illinois. Eric P. Schlaf Senior Economic Analyst Illinois Commerce Commission January 31, 2014

Net Metering in Illinois. Eric P. Schlaf Senior Economic Analyst Illinois Commerce Commission January 31, 2014 Net Metering in Illinois Eric P. Schlaf Senior Economic Analyst Illinois Commerce Commission January 31, 2014 Topics What is Net Metering Benefits of Net Metering Net Metering in US Net Metering in Illinois

More information

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT INTERCONNECTION AGREEMENT FOR SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION THIS AGREEMENT MUST ACCOMPANY

More information

RATE 765 RENEWABLE FEED-IN TARIFF

RATE 765 RENEWABLE FEED-IN TARIFF NORTHERN INDIANA PUBLIC SERVICE COMPANY Original Sheet No. 104 TO WHOM AVAILABLE Sheet No. 1 of 12 This Rate Schedule is a voluntary offer available to any Customer that operates within the Company s service

More information

Net Metering Program

Net Metering Program Net Metering Program Chapter 1 Purpose and Scope. The purpose of this chapter is to establish rules for determining the terms and conditions governing the interconnection of electric generation facilities

More information

EAU CLAIRE ENERGY COOPERATIVE FALL CREEK, WI Issue Date: 05/28/2014 Subject: New Distributed Generation Post May 28, 2014

EAU CLAIRE ENERGY COOPERATIVE FALL CREEK, WI Issue Date: 05/28/2014 Subject: New Distributed Generation Post May 28, 2014 SERVICE Page 1 of 5 I. PURPOSE To support distributed generation as a viable and sound means of meeting electric needs of various consumer groups, and establish the procedures for supporting such service

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to

More information

Net Metering Policy Framework. July 2015

Net Metering Policy Framework. July 2015 Net Metering Policy Framework July 2015 Table of Contents 1.0 BACKGROUND... 2 2.0 POLICY OBJECTIVE... 2 3.1 Eligibility... 3 3.1.1 Renewable Generation... 3 3.1.2 Customer Class... 3 3.1.3 Size of Generation...

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Rocky Mountain Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system

More information

Adopted: September 24, 2015 Version: Version 1.0

Adopted: September 24, 2015 Version: Version 1.0 Interconnection Standards for Parallel Installation and Operation of Customer Owned Renewable Electric Generating Facilities for Coon Rapids Municipal Utilities Adopted: September 24, 2015 Version: Version

More information

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2017 SESSION LAW HOUSE BILL 589

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2017 SESSION LAW HOUSE BILL 589 GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2017 SESSION LAW 2017-192 HOUSE BILL 589 AN ACT TO REFORM NORTH CAROLINA'S APPROACH TO INTEGRATION OF RENEWABLE ELECTRICITY GENERATION THROUGH AMENDMENT OF LAWS

More information

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY Virtual Net Metering Application Effective November 18, 2016 This application form addresses virtual net

More information

Revised Cal. P.U.C. Sheet No E** Pacific Gas and Electric Company Cancelling Revised Cal. P.U.C. Sheet No E San Francisco, California

Revised Cal. P.U.C. Sheet No E** Pacific Gas and Electric Company Cancelling Revised Cal. P.U.C. Sheet No E San Francisco, California Revised Cal. P.U.C. Sheet No. 25718-E** Pacific Gas and Electric Company Cancelling Revised Cal. P.U.C. Sheet No. 24808-E APPLICABILITY: TERRITORY: This voluntary schedule is available to customers for

More information

Proposal Concerning Modifications to LIPA s Tariff for Electric Service

Proposal Concerning Modifications to LIPA s Tariff for Electric Service Proposal Concerning Modifications to LIPA s Tariff for Electric Service Requested Action: The Trustees are being requested to approve a resolution adopting modifications to the Long Island Power Authority

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to

More information

Louisville Gas and Electric Company

Louisville Gas and Electric Company P.S.C. Electric No. 11, Original Sheet No. 57 APPLICABLE In all territory served. AVAILABILITY OF SERVICE Available to any customer-generator who owns and operates a generating facility located on Customer

More information

The Gambia National Forum on

The Gambia National Forum on The Gambia National Forum on Renewable Energy Regulation Kairaba Hotel, The Gambia January 31 February 1, 2012 Tariff and Price Regulation of Renewables Deborah Erwin Public Service Commission of Wisconsin

More information

Legal Considerations Related to Distributed Energy Resources

Legal Considerations Related to Distributed Energy Resources Legal Considerations Related to Distributed Energy Resources Steve Pincus Associate General Counsel Steve Shparber Counsel Markets & Reliability Committee April 18, 2016 Overview of FERC Jurisdiction FERC

More information

Municipality Generator Interconnection Application Single Meter Application Part I

Municipality Generator Interconnection Application Single Meter Application Part I Municipality Generator Interconnection Application Single Meter Application Part I New Application Revised Application A single customer interconnecting to a single meter at a single premise makes a new

More information

ELECTRIC SCHEDULE E-1 Sheet 1 RESIDENTIAL SERVICES

ELECTRIC SCHEDULE E-1 Sheet 1 RESIDENTIAL SERVICES Revised Cal. P.U.C. Sheet No. 33759-E Cancelling Revised Cal. P.U.C. Sheet No. 33566-E ELECTRIC SCHEDULE E-1 Sheet 1 APPLICABILITY: TERRITORY: RATES: This schedule is applicable to single-phase and polyphase

More information