MS10 Buoyancy Level Switch. Horizontal Mounted Electric Switch K-TEK Level products

Size: px
Start display at page:

Download "MS10 Buoyancy Level Switch. Horizontal Mounted Electric Switch K-TEK Level products"

Transcription

1 Operating instruction manual OI/MS10-EN Rev. F MS10 Buoyancy Level Switch Horizontal Mounted Electric Switch K-TEK Level products Introduction This operating instruction manual provides the following information: Specifications Ordering information Maintenance

2 Table of Contents 1.0 Introduction Specifications Approvals Ordering Information Maintenance Appendix Warranty Statement MS10 Buoyancy Level Switch Operating instruction manual

3 1.0 Introduction Description: The MS10 is a magnetically isolated single pole double throw point level switch. When the MS10 is inserted into a process vessel or external chamber it can sense high or low levels within the vessel. The unique magnetic isolation action eliminates the need for such things as seals, diaphragms, springs, or torque tubes because there is no physical contact with the process. he MS10 typically requires no preventive maintenance since it is totally sealed. The switch is not protected against radiation, electro-magnetic devices, parmeant magnets or excessive mechanical vibration. Operation: The MS10 will provide either a normally open or normally closed dry contact, which may be used to activate external devices such as alarms or solenoids. The capacity of the switch allows for control of a wide range of devices. Maximum voltage and current ratings are listed in the specification section of this manual. Variations in process fluid specific gravity (0.4 minimum clean fluid SG) have minimal effect because of the small size of the integral float. The float tracks the liquid level and provides for an electrical contact output (SPDT). These contacts are suitable for use with alarms and/or to activate a pump motor starter relay. Installation: The MS10 is mounted to the process vessel via the integral 1-1/2 MNPT fitting. Suitable reducers and/or adapters may be used provided they do not interfere with the full stroke of the float. The MS10 should be tightened such that the electrical connection is at its uppermost position. The following procedures outline the steps necessary to install the switch. WARNING! MAKE SURE CIRCUIT IS DE-ENERGIZED WHILE INSTALLING THE SWITCH. 1. Inspect the switch for any signs of damage incurred during shipment. Mount the switch in a process connection at the point in which you want the switch to trip. Use of a suitable lubricant/sealing compound is recommended. During final tightening, align the MS10 electrical connection to the topmost position as shown (Figure 1). A 2 wrench is needed for tightening. The electrical contacts may be installed either before or after installing the switch housing (Figure 2). Be sure to push the retainer assembly firmly into the switch housing during installation. The retainer assembly may be removed to facilitate removal of the switch assembly, if necessary. Note: The MS10 will also function when the electrical connection is aligned to the lowest position (bottom), however the electrical contacts will function opposite of the diagram (Figure 3). 2. Connect the field wires to the wiring harness of the MS10 according to the application. Reference Figure 3 for proper operation of contacts. Be sure to adequately insulate all electrical connections. 3. The liquid level inside the vessel should be cycled above and below the switch and operation of the contacts should be verified. 4. The float of the switch shall always be mounted in a straight horizontal position, arrow pointing up, so that the float of the switch is allowed to move freely up and down with the process. Obstruction of the float will cause inaccurate and erroneous readings to be relayed by the switch that could cause a hazardous condition to develop. 5. Competent personnel should only perform installation and maintenance procedures on process control equipment and these switches. 6. Placement of switches should be only where the effects of a hazardous atmosphere will not effect the material integrity of the apparatus. It is a requirement the installation personnel to assure the hazardous atmosphere or the surrounding atmosphere will not compromise the long-term integrity (strength, conductivity, corrosion) of the switch material. 7. Warranty/Repair/Replacement: 8. For warranty, repair, or replacement of transmitter call the ABB service department at The service department is located in Baton Rouge, LA 70817, USA. 9. The material construction of these units offers no particular protection against radiation, electro-magnetic or mechanical hazards. The construction of units is not designed to protect against other hazardous not defined in above sentence. 10. Strong magnetic fields should not be placed around the switch (reed switch is magnetically coupled) in order to prevent inaccurate and erroneous readings, which could cause a hazardous condition to develop. 11. Avoid aggressive substances that could drip, spill, pour, or fall on the switch and cause premature failure of the material or wiring resulting in inaccurate and erroneous readings which could lead to a hazardous condition. Specific Conditions of Use: 1. The supply connection for the apparatus is by an unterminated lead, and when installed, the connection must have an ingress protection level of at least IP The apparatus may be fitted with a titanium float. This must be taken into account during installation to prevent possible sparking. Operating instruction manual MS10 Buoyancy Level Switch 3

4 Figure 1 MS10 Alignment Vessel Wall Align to topmost position Switch Housing Figure 2 Installation of MS10 Electrical Contacts Switch Housing Retainer Assembly Reed Assembly Switch Assembly Figure 3 Operation of Electrical Contacts LEVEL ABOVE 1(RED) SWITCH C(WHITE) 2(BLACK) LEVEL BELOW SWITCH 1(RED) Note: A.) Field wiring connected to the MS10 switch must comply with applicable sections of the National Electrical Code. Do not install/use in environments that would allow the metal of the switch to react with the contents (liquid or vapor) which could cause corrosion and metal fatigue. C(WHITE) 2(BLACK) 4 MS10 Buoyancy Level Switch Operating instruction manual

5 2.0 Specifications Switch type Contact Material Switch Action Max Deadband Contact Ratings Magnetically actuated, hermetically sealed, bi-stable switch. Single pole, double throw (Form C) Rhodium alloy Break before make Approx. +/ of float travel AC rating (max): 250 V or 1 amp resistive or 100 VA DC rating (max): 125 V or 0.5 amp resistive or 100 W Lamp Load Rating: 1/3 125 VAC See IR10 for higher Switch Contact Ratings Process Temp. -40 to 450 F / -40 to 232 C Contact factory regarding use in colder applications Contact Temp. -40 to 302 F / -40 to 150 C Maximum Pressure Customer Connections Insertion Length Materials Specific Gravity 1500 psig / 103 bar standard 5000 psig / 345 bar with HP option 1-1/2 MNPT Process, 1/2 FNPT conduit and AWG 20 wiring harness (18 inch). MS10 housing is 2 Hex for tightening into process connection 4 (101mm) Standard; Optional 5 (127mm), 6 (152mm) or 6-1/2 (165mm) Up to 14 (356mm) Insertion Length 316/L Stainless Steel 0.4 Minimum (Clean Fluids) Consult Factory for Special Application Requirements 3.0 Approvals Factory Mutual Research Corp and CSA Canadian Standards Associations Hazardous Locations: FM CL I, Div 1& 2, GP A,B,C,D T6@Ta=176 F (80 C) DIP CL II, Div 1& 2, GP E,F,G CL III I /1 / AEx d IIC T6@Ta=176 F(80 C) IS I /1 / A,B,C,D T6@Ta=176 F(80 C) I /0/ AEx ia IIC T6@Ta=176 F(80 C) ATEX II 1 G Ex ia IIC T6 Ga (-40 C < Tamb < +80 C) (-40 F < Tamb < +176 F) MS50 Top of tank Liquid Level Switch (See datasheet (See DS-MS10-EN) datasheet MS ) MS10 Side Mounted Liquid Level Switch Mounted Via Flange MS10 Mounted Via 1 1/2" NPT MS10 with Custom Float (For Level Interface) MS10 Mounted Via 2" NPT Tee MS10 Mounted in Type EC Chamber Sample Application Using ABB Inc, K-TEK Level Switches Operating instruction manual MS10 Buoyancy Level Switch 5

6 pe, N material INFORMATION EXT3 & 6½ tating in. S6 / 165 from mm Insertion 316/L Stainless Length Steel Includes 1½ x 2 reducer bushing th Customer Specified Information HP Option Through Nozzle Installation 01-1 s dard 5 that EXT4 Flange in. or / are not 127 Designation standard required mm Insertion Length CST Carbon Steel 6 in. / 152 or not mm required Insertion Length (HP Option Only) Figure 1 Operation S2 2 Figure /b 1 Operation Tag of Socket with Electrical Weld, 3000# Customer of Contacts Modified Tee S4 Chart 304/L Stainless Steel Electrical Specified Information Includes 1½ x 2 reducer bushing Contacts None 6½ in. / 165 mm Insertion Length / er c Specified / EXTn d / e: Custom Information WPxx Welded Flange (specify type, Insertion Length HP material Option Through & X rating from Nozzle None Installation ot required CST Carbon Steel 2(BLACK) 6 in. / 152 mm Insertion Length (HP Option 316 Stainless 4.0 Ordering n Steel = 6⅝ Hanging to 14 Information / 168 Name to 356 Tagmm SLG Only) Figure 1 Operation /b Tag of with Electrical Customer Contacts Specified Information WPxx Welded Flange (specify Flange type, material Designation f & Chart) NT 316 Stainless Steel Hanging Name ss Connection Custom Insertion Length High X rating Pressure from None Option 2(BLACK) on /d less ION: minimum Length Other Options FLxx Loose Flange (specify type, material /c& rating Insertion from Length n Steel = Requires 6⅝ Hanging to 214 ½ minimum nozzle / 168 Name to ID Tag ½ mm SLG nozzle ID. Flange Designation Chart) NT LEVEL ABOVE 316 Stainless LEVEL SWITCHABOVE Steel Hanging SWITCH Name Tag (Standard) Options 4 in. 1½ Omit / MNPT 101 items mm (Standard) that Insertion are standard Length (Standard) SLG Flange Designation Chart) EXT1 4 in. / 101 mm Insertion Length (Sta 2 ½ nozzle ID. FLxx Loose or Flange not required (specify type, material LEVEL /c HP Up to 5000 psig / 345 bar 1(RED) & ABOVE rating Insertion from HP SWITCH Length HP Up 1(RED) to 5000 psig 345 bar 5 in. 2 / MNPT 127 mm Insertion Length EXT2 5 in. / 127 mm Insertion Length LEV None 1 mm Insertion 1. Length 3900 psig max (Standard) Mounting SLG Adapter Flange Material Designation Chart) EXT1 4 in. / 101 mm Insertion Length (Standard) with CRN approval. less psig max with CRN approval. 6½ Up 316/L in. Steel MS10.a.b.c.d.e.f.g: to / Stainless mm psig 2. Flanged / Insertion 345 Steel process bar Length connection T2 required 2 NPT, 3000# Modified 1(RED) Tee EXT3 6½ in. / 165 mm Insertion 1(RED) Length mm Insertion 3. Length EXT2 5 in. / 127 mm Insertion Length LEVEL BELOW Mounting Adapter Material psig max with Only CRN available approval. with EXT4 insertion length. Requires 2. 3½ less Flanged process connection required 6 in. 304/L Steel Includes 1½ x 2 reducer bushing / a152 Stainless Process mm Insertion Steel Connection Length (HP Option Only) EXT4 6 C(WHITE) in. / 152 mm C(WHITE) Insertion Length (HP Minimum Nozzle ID 65 mm 2. Flanged Insertion process 4. Contact Length connection T2 factory required regarding 2 NPT, materials 3000# of construction. Modified Tee EXT3 6½ in. / 165 mm Insertion 1(RED) Length el Custom 3. Only available 3. Only available with EXT4 insertion length Carbon Insertion CAUTION: Steel 5. with Requires EXT4 Length a insertion 3½ Requires 6 minimum 5/8 length. S2 2 Socket Weld, 3000# Modified Tee EXTn Custom Insertion Length Includes minimum to nozzle 14 1½ ID. x 2 / 2 reducer 168 ½ nozzle to bushing 356 ID. mm Requires 3½ mm Insertion Length (HP Option Only) EXT4 6 C(WHITE) in. / 152 mm Insertion Length (HP Option On Includes 1½ x 2 reducer bushing Minimum Nozzle ID /e 4. Approvals Contact factory regarding materials of construction. nge 4. Contact factory regarding materials of ressure Welded (specify Option 15 Flange type, 1½ (specify S2 MNPT type, & 2 rating Socket (Standard) material from Weld, & rating 3000# from Modified Tee n = 6⅝ to 14 in / 168 to 356 mm /b Tag with Customer Specified Information 2(BLACK) EXTn Custom Insertion Length sertion 5. Requires Length a 3½ 6 minimum 5/8 to nozzle 14 ID. in / 168 to 356 mm -1 Flange 2(BLACK) construction None SLG Designation 20 Flange Chart) Includes 1½ x 2 reducer bushing /d Other Options ify vals type, material & rating 2 MNPT Designation from Chart) n = 6⅝ to 14 in / 168 to 356 mm FM Factory Mutual ge ption (specify 5. Requires X a None 3½ minimum nozzle ID Up Loose None to 5000 Flange type, /b material Tag with WP psig (specify / Welded 345 bar type, & rating Customer 2(BLACK) CSX Canadian Standards Flange NT material from Specified Information 2(BLACK) Designation Chart) /d Other Options Association 316 & rating Flameproof Stainless from Steel Hanging Name Tag 6. HP HP uses a titanium Up to 5000 float psig / 345 bar Flange Factory Mutual 3900 SLG CSI psig Designation X FLCanadian max Flange Loose with Standards Chart) None y type, material & rating /c CRN Flange Designation Insertion approval. Association Chart) Length Intrinsically Safe 2(BLACK) psig max with CRN approval. 0 psig Canadian / 345 Standards bar NT from Association 316 Flameproof Stainless Steel Hanging Name gtag Approvals LEVEL BELOW LEVEL SWITCHBELOW SWITCH ting 2. aterial HP Up to 5000 Flanged Adapter CEI process Mounting Material ATEX Intrinsically connection Safe 2. psig Flanged / 345 process bar Designation EXT1 required 4 in. / 101 mm Insertion Length (Standard) connection required sig Canadian max with Standards Chart) /c CRN Insertion approval. Adapter Association Length Intrinsically Safe 3. 2 Only GR NPT, available 3000# GOST with Modified Russia High Pressure psig max 3. Only with (HP) available CRN approval. / EXT with EXT4 4 Option insertion length. 00# Modified Tee EXT4 Tee insertion EXT2 length. 5 in. / 127 mm Insertion LEVEL Length 1(RED) BELOW SWITCH 1(RED) 4. Contact factory regarding materials of const 2 d reducer process ATEX Intrinsically 4. Includes Contact GK bushing connection EXT1 Safe 1½ T2 factory x GOST 2 reducer 2 Kazakhstan required 4 in. / 101 mm Insertion Length (Standard) 2. Flanged process connection required regarding NPT, bushing 3000# EXT3 materials Modified 6½ of Tee 0539 construction. in. / 165 mm Insertion Length E1 ATEX / IECEx Exia Requires or 7/16 Ex Max naa 3½ minimum nozzle ID. Application vailable GOST HP Option Th eld, 5-1/4 Max 6-3/16 Max # with Russia High Pressure 3. Only (HP) available / EXT with EXT4 4 Option insertion length. ed Tee Requires Socket Inductive Modified EXT4 insertion EXT2 a Weld, 3½ Includes 3000# minimum and Tee Capacitive length. 5 in. / 127 mm Insertion Length 1(RED) Modified 1½ nozzle x 2 loads reducer Tee ID. require bushing special considerations. 4. Contact factory regarding materials of construction. shing EXT4 6 in. / 152 mm Insertion Length E2(HP /e Option ATEX Approvals / Only) IECEx Flameproof housing ct Note 2 reducer factory GOST Kazakhstan bushing regarding EXT3 Includes 1½ S2 Contact x 2 reducer 2 factory materials 6½ Socket bushing for Weld, technical of construction. in. / 165 mm Insertion 0539 Length Requires 7/16 Max a C(WHITE) 3½ minimum 3000# literature Modified and/or Tee applications HP nozzle Option N3 FM and CSA Ex Housing, Intrinsically C(WHITE) ID. Through N # safe or Specified ith als EXTn Custom Insertion Length es Inductive Modified a Customer 3½ minimum and Tee 5-1/4 Max 6-3/16 Max Information Capacitive assistance. EXT4 Specified nozzle loads Information ID. require 6 in. / 152 special mm considerations. Insertion Length (HP /e Option Approvals Only) shing Includes 1½ x 2 reducer n = bushing 6⅝ to 14 in / 168 to 356 mm Non-Incendive C(WHITE) Contact factory for technical literature and/or applications FM Factory Mutual Information None EXTn Custom Insertion Length assistance. None 7-3/8" /d Other Options Factory b Flanged Process Connection Material Application 2(BLACK) ss Steel Inductive 2(BLACK) CSX and Capacitive Canadian loads Standards require Association Fl 316 Stainless Mutual Hanging Name Steel Hanging Tag n = 6⅝ to 14 in / 168 to 356 mm FM Factory Mutual 4" X Name Tag 7-3/8" None Note special CSI considerations. Canadian Contact Standards factory Association for In ion Canadian Length Standards /d Other Association Options Flameproof 2(BLACK) anging utual Name Tag CSX Canadian Standards Association Flameproof 4" mm HP Up to 5000 psig / 345 bar Canadian 4 Insertion in. / 101 Standards 316 Length X mm Insertion 316L (Standard) Association None Stainless Length Steel Intrinsically (Standard) Safe CSI 2" technical Canadian CEI literature Standards ATEX and/or Intrinsically applications Association Safe assistance. Intrinsically S Standards Association Flameproof psig max with CRN approval. mm GR GOST Russia ATEX 5 Insertion in. Intrinsically / 127 Length CST mm Safe Insertion Carbon Steel Length 2-5/8 on 2. Flanged process connection required Standards Length (Standard) HP Up to 5000 psig / 345 bar CEI ATEX Intrinsically Safe Association Intrinsically Safe psig 2" max GK GOST Kazakhstan 5 mm 4-1/4" 3. Only with available CRN approval. with EXT4 insertion length. Requires 3½ Inductive 6½ Insertion c in. and / Process 165 Length insically on Length Capacitive mm Connection Insertion loads Length Size require / Rating special 4. Contact / Typeconsiderations. HP Option GR Safe factory regarding materials Services Through GOST of construction. will HP Application follow Option the Nozzle Russia model Through code Installation with Nozzle // and will 2 - Installation not 5/8 2. Flanged process connection required be Minimum Nozzle ID mm Inductive and Capacitive loads require 20 mm Contact 6 Insertion in. / factory 152 Length mm for Insertion (HP Option technical Length Only) GK GOST Kazakhstan rtion Length 4-1/4" 3. literature (HP available and/or Option 5. Requires with EXT4 Only) applications a insertion 3½ minimum length. assistance. Custom nozzle included ID. on the device tag 6.00 Requires 3½ and ertion Capacitive XXX Specify / EXT1 type, option material (standard) & tating from Note Contact factory for technical literature Length loads require special considerations. HP Option Through Nozzle Installation Minimum Nozzle ID 4. Contact factory regarding materials of construction. on Length (HP Insertion Option 20 mm Length Only) /e Approvals Application Inductive and Capacitive loads require special co actory 4 in n / = 168 for technical 6⅝ to to in mm SLG literature and/or 5. Requires / 168 to /8'' mm Flange applications a 3½ minimum Designation ashe e tag nozzle ID Chart assistance. gth / EXT1 option (standard) Note Contact factory for technical literature and/or app ll follow Options d the Tag model /e Approvals with Customer code with 5" Specified // and Information will not be included 7-3/8" to 356 mm 7-3/8'' FM Factory Mutual assistance. model 4" None code X with 5" None // and CSX will not be Canadian included Standards Association Flameproof 7-3/8" vices psig Up / 345 to 5000 bar FM Factory Mutual NT psig 316 / 345 Stainless bar CSI Steel Hanging Canadian Name Standards Tag Association Intrinsically Safe Wiring 4" Connection Photo ax with CRN approval. CSX Canadian Standards Association Flameproof psig max with CRN approval. ocess bar Certificate connection 2. eflanged Insertion of required process Completion CEI ATEX Intrinsically Safe connection CSI Length Wiring Connection Photo required Canadian Standards Association Intrinsically Safe Electrical Material 3. Only Test available with EXT4 insertion length. Requires 3½ EXT1 Report GR GOST Russia High Press ble approval. with EXT4 insertion length. Requires 3½ 2" tion tory of required regarding Completion CEI ATEX Intrinsically Safe materials of 4 construction. in. / 101 mm Insertion Length (Standard) Minimum Nozzle ID Minimum Nozzle ID Functional 4. Contact Test factory regarding materials /EXT2 of construction. option Connection 4-1/4" GK GOST Kazakhstan 0539 est 3½ Report minimum nozzle 5. Requires EXT2 ID. GR GOST Russia High Electrical Pressure (HP) insertion length. Requires 3½ a 3½ minimum 5 in. / 127 nozzle mm ID. Insertion Length Minimum Nozzle ID 20 mm materials of construction. 1/2 FNPT vals Certified as Built Drawing Application 5-1/4 Max Inductive and Capacitive loads require special considerations. 8-3/4" l Test EXT3 /EXT2 6½ in. option Connection 4-1/4" GK GOST Kazakhstan /16 Max nozzle ID. / 165 mm Insertion Length / EXT1 option (standard) Hydrostatic None Examination Note Contact factory for technical literature and/or applications 20 mm 1/2 FNPT s Built Drawing Application 5-1/4 Max 8-3/4" 6-1/2" Inductive and Capacitive loads require special considerations. EXT4 6 in. / 152 mm Insertion Length (HP Option tual NACE Factory Hardness Mutual Certificate assistance. / EXT1 option (standard) 7-3/8'' ic Examination Note Contact factory for technical literature and/or applications 6-1/2" Standards Canadian Only) Canadian Association Registration EXTN Standards Flameproof Number 7-3/8" 5" rdness Certificate 7-3/8'' Custom Association assistance. Insertion Length Flameproof tandards 6 5/8 to 14 in / 4" Association Registration Canadian Association Flameproof Number Standards Intrinsically 168 to Association Safe 5" 356 mm Intrinsically 7-3/8" Safe Association 100% sically ATEX Safe Radiographic Intrinsically Examination Safe 4" sia High Pressure 90 mm 100% GOST Liquid Russia Dye Penetrant Exam High (HP) 2" Pressure / EXT 4 (HP) Option fe / EXT 4 Option diographic Positive khstan Examination 0539 High Pressure (HP) / EXT 4 Option GOST Material Kazakhstan 90 mm Identification /EXT3 Without option Carbon Content " 11 7/16 Max uid 11 7/16 Max 4-1/4" 5-1/4 Max 6-3/16 Max Positive Capacitive Dye Penetrant 5-1/4 Max 6-3/16 Max Inductive Material and loads Capacitive require Exam Identification special loads 0539 With require considerations. Carbon special Content considerations. 11 7/16 Max /EXT2 option ry aterial 20 mm Contact for technical Identification factory literature /EXT3 Without option for technical and/or Carbon literature applications Content and/or applications 4-1/4" 5-1/4 Max 6-3/16 Max 6.00 aterial loads require Identification special With considerations. Carbon Content 8-3/4" assistance. / EXT1 option (standard) /EXT2 option ical literature and/or applications 20 mm /8" / EXT1 option (standard) 7-3/8'' 8-3/4" 6-1/2" 4" 4-1/4" 20 mm 4" 2" 4-1/4" 7-3/8" 20 mm 4-1/4" XT1 option EXT1 / (standard) EXT1 Option option (Standard) (standard) n (standard) 7-3/8'' 8'' 5" /EXT2 option 5" 2" 7-3/8'' /EXT2 option 0 mm 90 mm 6 MS10 Buoyancy Level Switch Operating instruction manual 2 option 8-3/4" 8-3/4" 6-1/2" 6-1/2" 2" 6-1/2" 5" 7-3/8'' 5" EXT2 /EXT2 Option option 6.00 /EXT2 option 8-3/4" 6-1/2" 8-3/4" /EXT3 option /EXT3 option 6.00 Wiring 2-5/8 2-5/8 Wiring Connec 90 mm 6.00 /EXT3 option EXT3 Option /EXT3 option Data sheet MS10 Buoyancy Level Sw Data sheet MS10 Buoyancy Level Switch Wiring Connection Wiring Connection Photo Photo Wiring Connection Photo Electrical Electrical 90 mm Electrical Connection Connection Connection 1/2 FNPT 1/2 FNPT 1/2 FNPT 6-1/2" 2-5/8 90 mm

7 Figure 4 Operation of Electrical Contacts 1 (RED) 2 (BLACK) 1 (RED) 2 (BLACK) LEVEL BELOW SWITCH HP Option Through Nozzle Installation Requires 3 1/2 Minimum Nossle ID HP Pressure (HP) EXT 4 Option 11 7/6 Max 5 1/4 Max 6 3/16 C (WHITE) C (WHITE) 5.0 Maintenance The MS10 does not require any routine maintenance in normal day to day operation. WARNING: If there is a need to take the switch out of service or disconnect it for any reason, then make sure the circuit is de-energized, or insure that the area is known to be non-hazardous! Handling & Storage Requirements: There are no special handling and storage requirements associated with this device. 6.0 Appendix Explosion Proof Installation: Many of ABB s switch products (MS10, LMS100, MS50) are based on magnetically operated reed switches. Since reed switches have the inherent characteristic of very closely spaced switch contacts, it is extremely important to protect these contacts from high voltage transients caused by inductive loads. When an inductive load is de-energized, the collapsing magnetic field induces a high voltage of opposite polarity into itself and thus the switch. Two basic methods exist to clamp this voltage and thus protect the switch contacts. D.C. Applications For D.C. applications, a diode is placed in parallel with the inductive load (note the polarity of the diode and power supply). A 1N4001 general purpose diode is normally sufficient to clamp the induced voltage of the inductive load to a safe level. D.C. Contact Protection + V - ø /8 REED SWITCH INDUCTIVE LOAD ø DIODE Wiring Connection Photo Electric Connection 1/2 FNPT Operating instruction manual MS10 Buoyancy Level Switch 7

8 A.C. Applications For A.C. applications, a Metal Oxide Varistor (MOV transient surge suppressor) is placed either in parallel with the switch or the inductive load. The MOV changes from a high impedance to a very low impedance when the voltage across the MOV exceeds its rated voltage (the MOV rating must correspond with the power supply voltage). For 120 VAC control systems a typical MOV would be part number V130LA10A provided by Littelfuse. In either case shown, the result is the limiting of the switch voltage to approximately 130 volts. A.C. Contact Protection Explosion Proof Applications The switch has been rated for explosion proof applications by FM Global and CSA Group only. For typical/specific explosion proof installation see NEC 500 or NEC 505, or IEC directives. The MS10 is not approved for flameproof (European) application at this time. Intrinsically Safe Applications This switch is ATEX approved in IS installations (Ex ia) Zone 0 in Europe by FM Global, in the U.S. by FM and in Canada by CSA This switch can be used in areas/processes that do not have explosive environments. For a typically IS installation application please see the example below. REED SWITCH REED SWITCH OR INDUCTIVE LOAD MOV INDUCTIVE LOAD If only two wires are used, then the 3 rd wire must be electrically and physically insulated from the circuit. For use with three (3) wires, that is, use of the Normally Closed (NC) and Normally Opened (NO) contacts, a second IS barrier is required. This IS installation hook-up is good for: Europe under ATEX approval U.S. under FM approval Canada under CSA approval ATEX Note: High Pressure (HP) option switch uses a titanium float. Caution: Foreign objects (metals made of other material) sticking the titanium float could cause a spark. Use caution to prevent such conditions for arising. MOV 8 MS10 Buoyancy Level Switch Operating instruction manual

9 Approval Markings D 2460 NOTE 5 4 ATEX & IECEx: HAZARDOUS AREA II 1 G Ex ia IIC T6 Ga (-40 C <Ta <80 C) FM16ATEX0003X IECEx FMG X SWITCH SHOWN IN LOW LEVEL POSITION (FLOAT BELOW SWITCH) CONTACTS OPEN WHEN FLOAT TRAVELS ABOVE SWITCH FOR OPPOSITE OPERATION USE CONTACT 1 INSTEAD OF 2. 3 NON-HAZARDOUS AREA 2 GENERAL NOTES: Ui: 100V; Ii: 700mA; Pi: 1.7W; Ci: 0uF; Li: 0uH. 1 REV REASON APPROVED DATE NC FIRST RELEASE E.F. 07/22/02 A ATEX EDIT R.T. 04/07/03 B EDIT RATINGS R.T. 11/05/03 C ECN0946 MS 06/02/16 SYSTEM CALCULATIONS: ADD CABLE CAPACITANCE & INDUCTANCE TO SWITCH ENTITY PARAMETERS (I.E. ALL FIELD INSTALLED CAPACITANCE & INDUCTANCE MUST BE CONSIDERED) IF CABLE PARAMETERS ARE NOT KNOWN, 60pF/ft & 0.2uH/ft SHOULD BE USED. D NOTE 2, 4 & 6 C C 2 (WHITE) (BLACK) APPROVED (CERTIFIED) SINGLE OR MULTIPLE CHANNEL ZENER BARRIER CUSTOMER WIRING C (RED) 1 NOTE 3 B I.S. GROUND B A NOTES RELATED TO ATEX APPROVAL 1. ALL SWITCH CONTACTS MUST BE CONNECTED TO A PROTECTIVE BARRIER OR NOT IN USE. 2. SINGLE OR MULTIPLE CHANNEL PROTECTIVE BARRIER PARAMETERS MUST MEET THE FOLLOWING REQUIREMENTS: V(oc) OR V(t) <= 100V, I(sc) OR I(t) <= 700mA, I(t) < 1.7 Watts C(a) >= C(i) + C(cable), L(a) >= L(i) + L(cable). * SUPPLY MUST BE ATEX CERIFIED Ex ia IIC 3. INSTALLATION SHALL CONFORM TO MANUFACTURERS INSTRUCTIONS SUPPLIED WITH THE PROTECTIVE BARRIER AS WELL AS APPROPRIATE SAFETY REGULATIONS EN MAXIMUM NON-HAZARDOUS VOLTAGE AREA SHOULD NOT EXCEED 250V(rms). 5. SWITCH CONNECTION SHOWN FOR FAIL-SAFE OPERATION (CONTACTS OPEN ON ALARM). IF HIGH LEVEL ALARM IS REQUIRED INSTEAD OF LOW ALARM, CONNECT AS PER NOTE. 6. PROTECTIVE ZENER BARRIER IS NOT REQUIRED FOR NON-INCENDIVE APPLICATIONS. 4 3 The information contained herein is proprietary to and considered a trade secret of ABB Inc., and shall not be reproduced, in whole or in part, without the written authorization of ABB Inc. 2 THIS DOCUMENT WILL BE SUPPLIED WITH EACH SWITCH (USERS MANUAL). CRITICAL / SCHEDULE DOCUMENT NO MODIFICATION PERMITTED WITHOUT APPROVAL FROM AGENCY / NOTIFIED BODY K-TEK PRODUCTS Manchac Park Lane (Suite-B) Baton Rouge, La Title: ELECTRICAL INSTALLATION DRAWING ATEX & IECEx INTRINSICALLY SAFE APPLICATIONS Doc. Type: ELECTRICAL INSTALLATION DRAWING Prepared by: Approved by: Norman W Guidry MS Sreekanth Part No.: MS Drawing No.: MS Resp. BU: LEVEL PRODUCTS Lang.: EN Rev. Date: 06/02/16 Rev.: Sheet: C 1 of 1 A Operating instruction manual MS10 Buoyancy Level Switch 9

10 U.S. under FM approval / Canada under CSA approval 4 Factory Mutual: HAZARDOUS AREA CL I, DIV 1 & 2, GP A,B,C,D CL 1, Zn 1, AEx d IIC CL 1, Zn 0, AEx ia IIC DIP CL II, DIV 1 & 2, GP EFG, CLASS III 3 CSA: HAZARDOUS AREA CL I, DIV 1 & 2, GP A,B,C,D CL 1, Zn 1, Ex d IIC CL 1, Zn 0, Ex ia IIC CL II, DIV 1 & 2, GP EFG, CLASS III NON-HAZARDOUS AREA 2 1 REV REASON APPROVED DATE NC FIRST RELEASE E.F. 06/21/01 A CSA APPROVAL R.T. 04/29/02 B ECN0946 E.F. 11/17/15 D NOTE 2,4 & 7 D C 2 (WHITE) (BLACK) APPROVED (CERTIFIED) SINGLE OR MULTIPLE CHANNEL ZENER BARRIER CUSTOMER WIRING (RED) 1 NOTE 3 NOTE 6 SWITCH SHOWN IN LOW LEVEL POSITION (FLOAT BELOW SWITCH) CONTACTS OPEN WHEN FLOAT TRAVELS ABOVE SWITCH FOR OPPOSITE OPERATION USE CONTACT 1 INSTEAD OF 2. I.S. GROUND C B NOTES RELATED TO FM APPROVAL: 1. THE MS10 SERIES CONFORMS TO FMRC APPROVAL STANDARD. INTRINSICALLY SAFE FOR USE IN CLASS I, ZONE 0, CLASS II, & CLASS III HAZARDOUS (CLASSIFIED) LOCATIONS. ENTITY PARAMETERS: Ui=100V, Ii=750mA, Ci=0uF, Li=0mH. INTRINSICALLY SAFE FOR USE IN CLASS I, ZONE 0 CLASS II & CLASS III HAZARDOUS (CLASSIFIED) LOCATIONS. 2. SINGLE OR MULTIPLE CHANNEL PROTECTIVE BARRIER PARAMETERS MUST MEET THE FOLLOWING REQUIREMENTS: V(oc) OR V(t) <= 100V, I(sc) OR I(t) <= 750mA, C(a) >= C(i) + C(cable), L(a) >= L(i) + L(cable). 3. INSTALLATION SHALL CONFORM TO MANUFACTURERS INSTRUCTIONS SUPPLIED WITH THE PROTECTIVE BARRIER AS WELL AS THE NATIONAL ELECTRIC CODE AND ANSI/ISA-RP (INSTALLATION OF INTRINSICALLY SAFE INSTRUMENT SYSTEMS IN HAZARDOUS (CLASSIFIED) LOCATIONS). 4. MAXIMUM NON-HAZARDOUS VOLTAGE AREA SHOULD NOT EXCEED 250V(rms). 5. THE MS10 SERIES SWITCH IS CONSIDERED A SIMPLE APPARATUS IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NFPA) AND ANSI/ISA-RP SWITCH CONNECTION SHOWN FOR FAIL-SAFE OPERATION (CONTACTS OPEN ON ALARM). IF HIGH LEVEL ALARM IS REQUIRED INSTEAD OF LOW ALARM, CONNECT AS PER NOTE BELOW SWITCH CONTACTS. 7. PROTECTIVE ZENER BARRIER IS NOT REQUIRED FOR NON-INCENDIVE APPLICATIONS WHEN INSTALLED PER NATIONAL ELECTRIC CODE. 8. ALL SWITCH CONTACTS MUST CONNECTED TO A PROTECTIVE BARRIER OR NOT IN USE. NOTES RELATED TO CSA APPROVAL: 1. THE MS10 SERIES CONFORMS TO CSA APPROVAL STANDARD. INTRINSICALLY SAFE FOR USE IN CLASS I, ZONE 0, CLASS II, & CLASS III HAZARDOUS (CLASSIFIED) LOCATIONS. ENTITY PARAMETERS: Vmax, Ui=100V, Imax, Ii=750mA, Ci=0uF, Li=0mH. INTRINSICALLY SAFE FOR USE IN CLASS I, ZONE 0 CLASS II & CLASS III HAZARDOUS (CLASSIFIED) LOCATIONS. 2. SINGLE OR MULTIPLE CHANNEL PROTECTIVE BARRIER PARAMETERS MUST MEET THE FOLLOWING REQUIREMENTS: V(oc) OR V(t) <=100V, I(sc) OR I(t) <=750mA, C(a) >= C(i) + C(cabel), L(a) >= L(i) + L(cable). 3. INSTALLATION SHALL CONFORM TO MANUFACTURERS INSTRUCTIONS SUPPLIED WITH THE PROTECTIVE BARRIER AS WELL AS THE CANADIAN ELECTRICAL CODE AND ANSI/ISA-RP (INSTALLATION OF INTRINSICALLY SAFE INSTRUMENT SYSTEMS IN HAZARDOUS (CLASSIFIED) LOCATIONS). 4. MAXIMUM NON-HAZARDOUS VOLTAGE AREA SHOULD NOT EXCEED 250V(rms). 5. THE MS10 SERIES SWITCH IS CONSIDERED A SIMPLE APPARATUS IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE AND ANSI/ISA-RP SWITCH CONNECTION SHOWN FOR FAIL-SAFE OPERATION (CONTACTS OPEN ON ALARM). IF HIGH LEVEL ALARM IS REQUIRED INSTEAD OF LOW ALARM, CONNECT AS PER NOTE BELOW SWITCH CONTACTS. 7. PROTECTIVE ZENER BARRIER IS NOT REQUIRED FOR CLASS 1 DIVISION 2 APPLICATIONS WHEN INSTALLED PER CANADIAN ELECTRICAL CODE. 8. ALL SWITCH CONTACTS MUST CONNECTED TO A PROTECTIVE BARRIER OR NOT IN USE. C B CRITICAL / SCHEDULE DOCUMENT NO MODIFICATION PERMITTED WITHOUT APPROVAL FROM AGENCY / NOTIFIED BODY A 4 THIS DOCUMENT WILL BE SUPPLIED WITH EACH SWITCH (USERS MANUAL). 3 K-TEK PRODUCTS Manchac Park Lane (Suite-B) Baton Rouge, La The information contained herein is proprietary to and considered a trade secret of ABB Inc., and shall not be reproduced, in whole or in part, without the written authorization of ABB Inc. 2 Title: ELECTRICAL INSTALLATION DRAWING FM & CSA INTRINSICALLY SAFE APPLICATIONS Doc. Type: ELECTRICAL INSTALLATION DRAWING Prepared by: Approved by: Norman W Guidry MS Sreekanth Part No.: MS Drawing No.: MS Resp. BU: LEVEL PRODUCTS Lang.: EN Rev. Date: 11/17/15 Rev.: Sheet: B 1 of 1 A 10 MS10 Buoyancy Level Switch Operating instruction manual

11 Replacement of switch (SPDT) on the MS10: * The MS10 switch must be replaced with ABB s part number MS10-4 reed switch because the switch is potted for dimensions to fit inside of the SS tubing. 1. Disconnect the power that runs through/to the switch (Assure that removing the power will not effect your process or process control) 2. Lock-out and Tag-out the power so that power can not be applied to the switch until after the switch has been completely repaired/replaced 3. It is not necessary to remove the MS10 from the process to replace the reed switch 4. Remove retaining ring with small screwdriver 9. Disconnect the wires (2 or 3 wires) on old switch, noting the connections and colors, and re-connect the wires to the new switch according to hook-up of the old wiring. 10. Ensure that the applied wattage & current do not exceed the power & current rating of the switch 11. Remove the Lock-out / Tag-out device from the applied power 12. Before applying power assure that this will not effect your process or process control 13. Apply power and check the switch to assure that it is functioning properly Note: For the switch to operate (make and break contact) in the process, the fluid/process must be lower and raised above the level of the float. 5. Remove the rubber grommet 6. Pull out the magnetic reed switch by the wires 7. Put in the replacement reed switch 8. Replace grommet & retaining ring Operating instruction manual MS10 Buoyancy Level Switch 11

12 6.0 Declaration of Conformity For the latest MS10 EU Declaration of Conformity, click this link or visit here: measurement-products/level/buoyancy-level-sensors-and-switches/ms10-electric-level-switch 12 MS10 Buoyancy Level Switch Operating instruction manual

13 7.0 Warranty Statement 5 YEAR WARRANTY FOR: KM26 Magnetic Liquid Level Gauges; MagWave Dual Chamber System; LS Series Mechanical Level Switches (LS500, LS550, LS600, LS700, LS800 & LS900) (does NOT include switching mechanisms, ie. MS40, LMS100, MS41, PS35 & PS45); EC External Chambers, STW Stilling Wells and ST95 Seal Pots. 2 YEAR WARRANTY FOR: AT100, AT100S and AT200 series transmitters; RS85 liquid vibrating fork switches; TX & TS, thermal dispersion switches; IR10 and PP10 External Relays; MT5000, MT5100 and MT5200 radar level transmitters; RI100 Repeat Indicators; KP paddle switches; A02 & A75 RF capacitance level switches; Buoyancy Level Switches (MS50 & MS10); Magnetic Level Switches (MS40, MS41, PS35, PS45 and LMS100). 1 YEAR WARRANTY FOR: AT500 and AT600 series transmitters; DPM100 digital indicators; APM100 analog indicators; GRANUPOINT vibrating fork switches. SPECIAL WARRANTY CONSIDERATIONS: ABB Inc, K-TEK Products, does not honor OEM warranties for items not manufactured by ABB Inc, K-TEK Products, (i.e. Palm Pilots). These claims should be handled directly with the OEM. ABB Inc, K-TEK Products, will repair or replace, at ABB Inc, K-TEK Product s, election, defective items which are returned to ABB Inc, K-TEK Products, by the original purchaser within the period specified above from the shipment date of the item and which is found, upon examination by ABB Inc, K-TEK Products, to its satisfaction, to contain defects in materials or workmanship which arose only under normal use and service and which were not the result of either alterations, misuse, abuse, improper or inadequate adjustments, applications or servicing of the product. ABB Inc, K-TEK Products s, warranty does not cover the repair or replacement of units that fail from the effects of excessive vibration unless the units are originally designed for vibration application. In addition, ABB Inc, K-TEK Products s warranty does not include on-site repair or services. Field service rates can be supplied on request. (service@ktekcorp.com) to determine an optimal solution for shipping method and turnaround time.) The product, with repaired or replaced parts, shall be returned to the purchaser at any point in the world with transportation prepaid by ABB Inc, K-TEK Products, for best-way transportation only. ABB Inc, K-TEK Products, is not responsible for expedited shipping charges. If the product is shipped to ABB Inc, K-TEK Products, freight collect, then it will be returned to the customer freight collect. If inspection by ABB Inc, K-TEK Products, does not disclose any defects in material or workmanship, ABB Inc, K-TEK Product s, normal charges for repair and shipment shall apply (minimum USD). The materials of construction for all ABB Inc, K-TEK products, are clearly specified and it is the responsibility of the purchaser to determine the compatibility of the materials for the application. THE FOREGOING WARRANTY IS ABB INC, K-TEK PRODUCT S, SOLE WARRANTY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, ARE EXCLUDED AND NEGATED TO THE MAXIMUM EXTENT PERMITTED BY LAW. NO PERSON OR REPRESENTATIVE IS AUTHORIZED TO EXTEND ANY OTHER WARRANTY OR CREATE FOR ABB INC, K-TEK PRODUCTS, ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ABB INC, K-TEK S PRODUCTS. THE REMEDIES SET FORTH IN THIS WARRANTY ARE EXCLUSIVE OF ALL OTHER REMEDIES AGAINST ABB INC, K-TEK PRODUCTS. ABB INC, K-TEK PRODUCTS, SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES OF ANY KIND. ABB INC, K-TEK PRODUCT S, SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE PARTS (FOUND TO BE DEFECTIVE IN MATERIALS OR WORKMANSHIP) WHICH ARE RETURNED BY THE PURCHASER TO ABB INC, K-TEK PRODUCTS. If a product is believed to be defective, the original purchaser shall notify ABB Inc, K-TEK Products, and request a Returned Material Authorization before returning the material to ABB Inc, K-TEK Products, with transportation prepaid by the purchaser. (To expedite all returns/repairs from outside of the United States, consult ABB Inc, K-TEK Product s customer service team Operating instruction manual MS10 Buoyancy Level Switch 13

14 Contact us ABB Inc. Industrial Automation 125 E. County Line Road Warminster, PA USA Tel: Fax: ABB Inc Manchac Park Lane - Suite B Baton Rouge, LA USA Phone: Service: Fax: Service service@us.abb.com Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2017 ABB All rights reserved 3KXL535001R4201 OI/MS10-EN Rev. F ABB Engineering (Shanghai) Ltd. No. 4528, KangXin Hwy. Pudong New District Shanghai, , P.R. China Phone: Service: Fax: norman-suijun.xia@cn.abb.com Service rola.li@cn.abb.com Sales Service

MS40/EX Magnetic Level Gauge Switch. Magnetically actuated 10 amp DPDT electric switch. K-TEK Level products

MS40/EX Magnetic Level Gauge Switch. Magnetically actuated 10 amp DPDT electric switch. K-TEK Level products Operating instruction manual OI/MS40-EN Rev. D MS40/EX Magnetic Level Gauge Switch Magnetically actuated 10 amp DPDT electric switch K-TEK Level products Introduction This operation and instruction manual

More information

MS41 Magnetic Level Gauge Switch. Magnetically actuated 10 amp hermetically sealed electric switch K-TEK Level products

MS41 Magnetic Level Gauge Switch. Magnetically actuated 10 amp hermetically sealed electric switch K-TEK Level products Operating instruction manual OI/MS41-EN Rev. D MS41 Magnetic Level Gauge Switch Magnetically actuated 10 amp hermetically sealed electric switch K-TEK Level products Introduction This operation and instruction

More information

LS Series Buoyancy Level Switch. Mechanical Level Switch K-TEK Products

LS Series Buoyancy Level Switch. Mechanical Level Switch K-TEK Products Operating instruction manual OI/LS-EN Rev. B LS Series Buoyancy Level Switch Mechanical Level Switch K-TEK Products Introduction This operating instruction manual provides the following information: Installation

More information

MS40 MS40/EX Explosion

MS40 MS40/EX Explosion MS40 MS40/EX Explosion MS40-0200-1 Rev c (10-2010) DCN0530 Table of Contents 1.0 Description..... 3 2.0 Application..3 3.0 Operation.3 4.0 Mounting & Installation 3-4 5.0 Maintenance 4 6.0 Warranty Statement..9

More information

MS Rev c ( ) DCN0530

MS Rev c ( ) DCN0530 MS41-0200-1 Rev c (10-2010) DCN0530 Table of Contents 1.0 Description... 3 2.0 Application... 3 3.0 Operation... 3 4.0 Mounting & Installation... 3-4 5.0 Installation and Wiring... 5 6.0 Warranty Statement...

More information

RS85 Vibrating fork level switch

RS85 Vibrating fork level switch Data sheet DS/-EN Rev. P Multi-option liquid level switch K-TEK Level products Measurement made easy Features Direct replacement for ultrasonic Gap switches, RF capacitance switches, float switches and

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products Operating instruction manual OI/GP50-EN Rev. B GP50 Vibrating Fork Level Switch Vibrating level switch for powders and granular solids K-TEK Products Introduction This operating instruction manual provides

More information

PS45 Magnetic Level Gauge Switch. Magnetically actuated no-bleed switch K-TEK Products

PS45 Magnetic Level Gauge Switch. Magnetically actuated no-bleed switch K-TEK Products Operating instruction manual OI/PS45-EN Rev. C PS45 Magnetic Level Gauge Switch Magnetically actuated no-bleed switch K-TEK Products Introduction This operation and instruction manual provides the following

More information

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products Data sheet DS/AT100-EN Rev. S AT100 Magnetostrictive Level Transmitter High accuracy magnetostrictive liquid level transmitter K-TEK Products Features SIL2 certified IEC 61508* High accuracy:.01% of full

More information

GP Rev a ( ) DCN0533

GP Rev a ( ) DCN0533 TABLE OF CONTENTS 1.0 INTRODUCTION.....3 Function Range of Application Typical Installations 2.0 TECHNICAL DATA.....5 General Dimensions Mechanical Data Electrical Data Operating Conditions 3.0 MOUNTING......8

More information

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products Data sheet DS/MW05-EN Rev. C MW05 MagWave Magnetic Level Gauge Dual chamber level system K-TEK Products Multiple Chamber Styles 24 Preconfigured Styles Plus Custom Styles Left Hand or Right Hand Mounted

More information

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

Fisher i2p 100 Electro Pneumatic Transducer

Fisher i2p 100 Electro Pneumatic Transducer Product Bulletin D103197X012 i2p 100 Transducer Fisher i2p 100 Electro Pneumatic Transducer The Fisher i2p 100 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a milliampere

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

WARNING! READ BEFORE INSTALLATION

WARNING! READ BEFORE INSTALLATION A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET WARNING! READ BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure,

More information

Installation & Operation Manual RS80/RS85. Vibrating Fork Level Switch. For the latest version of this manual, visit ktekcorp.com.

Installation & Operation Manual RS80/RS85. Vibrating Fork Level Switch. For the latest version of this manual, visit ktekcorp.com. Installation & Operation Manual RS80/RS85 RS80 RS85 For the latest version of this manual, visit ktekcorp.com. Table of Contents 1.0 Introduction... 3 1.1 Description... 3 1.2 Theory of Operation... 3

More information

m WARNING! READ m BEFORE INSTALLATION

m WARNING! READ m BEFORE INSTALLATION m WARNING! READ m BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature,

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation

More information

KP Specialty Level Instruments. Rotary Paddle Switch K-TEK Products

KP Specialty Level Instruments. Rotary Paddle Switch K-TEK Products Operating instruction manual OI/KP-EN Rev. G 04.2013 KP Specialty Level Instruments Rotary Paddle Switch K-TEK Products Introduction This operating instruction manual provides the following information:

More information

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive

More information

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions FAIRCHILD T800 SERIES STANDARD RANGE MINIATURE TWO-WIRE, PI PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions Model TT800 Model TA800 Model TD800 Inlet Port (Channel 2) Inlet Port

More information

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Switch-Tek Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA

More information

J 6 Se r i e s. Pressure and Vacuum switches. features

J 6 Se r i e s. Pressure and Vacuum switches. features J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows

More information

BMRX Series ROTARY LEVEL CONTROL

BMRX Series ROTARY LEVEL CONTROL BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

EG Series Installation Manual

EG Series Installation Manual EG Series Installation Manual Convenient Micro Connectors (M) speed installation and maintenance Enclosure is fully potted and sealed to eliminate threat of moisture contamination in the wiring and electronics

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions FAIRCHILD T500 SERIES ELECTRO-PNEUMATIC TRADUCER Installation, Operation and Maintenance Instructions Identification Number Underwriting Group Factory Mutual Canadian Standard T (F) (C) 500- Approval Class

More information

Fisher 3660 and 3661 Positioners

Fisher 3660 and 3661 Positioners 3660 and 3661 Positioners Product Bulletin Fisher 3660 and 3661 Positioners Fisher 3660 pneumatic and 3661 electro pneumatic single acting positioners are used with various actuators on sliding stem valves

More information

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 - Type 2000 Pneumatic and Electropneumatic Valve Positioner Installation, Operation and Maintenance Instructions Ordering Information Use this coding system to order Model CA20 - Type of Positioner 00 P/P

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

V200 Series Positioners

V200 Series Positioners V200 Series Positioners In a single compact and rugged housing The V200 positioner incorporates the flexibility of converting from a pneumatic unit to several versions of an electropneumatic unit, and

More information

LMG100 Econolev Magnetic level gauge KTEK products. Measurement made easy

LMG100 Econolev Magnetic level gauge KTEK products. Measurement made easy Operation instruction manual OI/LMG100-EN LMG100 Econolev Magnetic level gauge KTEK products Measurement made easy Introduction ABB offers the standard LMG100 Econolev Magnetic Level Gauge with a 316 stainless

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L E L E C T R I C L E V E L C O N T R O L S LINC L471 L471SC LV471 L971 SERIES Recognized as a world-class leader in Electric & Pneumatic level control switches, flow indicators, chemical metering pumps,

More information

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance  Output Range Type 500X Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions Ordering Information Type 500X I/P Transducers Output Range Part Number Input psi bar Impedance Pilot

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller Switch-Pak w/ Compact Relay Controller AU13, AV13 & AZ13 Series Owner s Manual Flowline, Inc.. 10500 Humbolt Street, Los Alamitos, CA 90720. p 562.598.3015. f 562.431.8507. w flowline.com MN301430 Rev

More information

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS

More information

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051CFA Annubar Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer CONTROL SYSTEMS 1239 WILLOW LAKE BOULEVARD VADNAIS HEIGHTS, MINNESOTA 55110 651 766 2700 Fax: 651 766 2701 www.control systems.usfilter.com Product Specification A1000i Loop Powered/4-20mA Submersible

More information

1500 Series Level Switches

1500 Series Level Switches SEE MORE AT SORInc.com Request Quote 1500 Series The SOR family of 1500 series mechanical level switches answer industry s call for less expensive alternatives to the traditional chambered level switch.

More information

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom

More information

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator Contents Data Sheet Rev. A RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator For continuous positioning, In explosion-proof design, Rated force 10 kn / 20 kn (2200 lbf / 4400 lbf) Electrical actuator

More information

PT-500 Analog Output Series User Manual

PT-500 Analog Output Series User Manual PT-500 Analog Output Series User Manual 4-20 ma, 0-5 VDC, 0-10 VDC, mv/v R Doc #9004194 Rev A2, 08/16 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications

More information

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Installation and Maintenance Instructions 44TA Liquid Level Float Switch OPW Installation, Operation and Maintenance Manual, Page 54 MPORTANT: Please read these warnings and use the assembly instructions completely and carefully before starting. Failure to do so may cause product

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL L007 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L007 Side- Mounted

More information

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter Product Bulletin D200437X012 3710 and 3720 Positioners Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter Fisher 3710 pneumatic (figure 1) and 3720 electro pneumatic positioners (figure

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua Dr. Oliveira Salazar, nº 88 4780-453 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 809 124 Fax. +351 252 859 298

More information

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL S003 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information

More information

Capacitive level sensors CLS 23

Capacitive level sensors CLS 23 For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL

More information

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc. AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RPM Series Float Level Sensors Rev. E, 08/16 Doc. 9002103 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com

More information

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control Type 900X Miniature I/P, E/P Transducer for Electronic Air Pressure Control Self-correcting to maintain precise control Available with zero-based ranges The Type-900X I/P, E/P transducer converts an electrical

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Tuffy Liquid Level Switches

Tuffy Liquid Level Switches Tuffy Liquid Level es Tuffy liquid level switches are designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. Models are equipped with a single electric or pneumatic

More information

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc. All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed as warranties

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer CONTROL SYSTEMS 1239 WILLOW LAKE BOULEVARD VADNAIS HEIGHTS, MINNESOTA 55110 651 766 2700 Fax: 651 766 2701 www.control systems.usfilter.com Product Specification A1000i Loop Powered/4-20mA Submersible

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control Miniature I/P, E/P Transducer for Electronic Air Pressure Control Self-correcting to maintain precise control The Type-900X I/P, E/P transducer converts an electrical signal (current or voltage) to a proportional

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...

More information

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T5220 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA EchoPod Ultrasonic Level Switch, Controller & Transmitter DL10, DL14, DL24, DS14 & DX10 Series Quick Start DL14-00 Shown 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

1000 Series Piston Type Differential Pressure Gauges

1000 Series Piston Type Differential Pressure Gauges 1000 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...

More information

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch L001

More information

Features. Flexibility

Features. Flexibility The V100 positioner can be ordered as a base model pneumatic positioner, converted to standard NEMA 4X electropneumatic, EX model, or FF (fail freeze) model in a matter of minutes, without removing the

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional

More information

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A Mid-West Instrument ELECTRICAL Upon receipt of your order, please review the ratings plate to verify that the model number and the electrical ratings match the product that you ordered. Figure 1 is the

More information

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter Product ulletin D200064X02 360J and 3620J Positioners Fisher 360J and 3620J Positioners and 3622 Electro Pneumatic Converter Fisher 360J or 360JP pneumatic and 3620J or 3620JP electro pneumatic positioners

More information

Measurement Products - Measurement Made Easy. Guided Wave Radar Level Transmitters K-TEK Products

Measurement Products - Measurement Made Easy. Guided Wave Radar Level Transmitters K-TEK Products Measurement Products - Measurement Made Easy Guided Wave Radar Level Transmitters K-TEK Products Index 3 Introduction 4 Principle of operation 6 Industries and applications 7 Specifications 8 Contact Us

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

LMS200 Magnetic level gauge switch

LMS200 Magnetic level gauge switch ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION LMS200 Magnetic level gauge switch Non-invasive magnetically actuated point level switches that require no power to operate are an enhancement to a magnetic

More information

102 Differential Pressure Switch

102 Differential Pressure Switch Knurled cap over set point adjustment High side process connection 1/4 NPT(F) [1/2 NPT(F) optional] onal] Hermetically sealed switching element capsule with 18 AWG wire leads, 18 (45.7 cm) in length 102

More information

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise Data Sheet DS/WEP-EN Rev. C Model WEP Electro-pneumatic positioner WEP positioner A valve control without compromise Standard - ma input Single acting, force-balance operating principle Excellent dynamic

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units ABB MEASUREMENT & ANALYTICS DATA SHEET Series 4234-500 and 4234-600 Katharometer power supply units 2 SE RIE S 4 23 4-500 AN D 4 23 4-600 K ATHAROME TE R POWE R SU PPLY U NITS DS/4 23 4-E N RE V. F Measurement

More information

SPC-PANEL Simplex, Single Phase Pump Control Panel

SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100P, 101P, 110P, 180P, 200P, 201P ADJUSTABLE PRESSURE SWITCHES; MODEL 160P ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES, ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches 2100 and 2100E Level Switches Product Bulletin Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches Fisher 2100 on-off pneumatic switch and 2100E electric switch sense (shown in figure 1) high

More information