1 Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin onded balanced poppet Return spring Manifold mounting Stacking plug-in Exh. In plug-in with pressure regulators plug-in with flow controls SERIES FETURES plug-in with PR & FC Patented high force MCSOLENOID for fastest possible response times. onded balanced poppet for high flow, precise repeatability, and consistent operation. alanced poppet permits versatility in function may be used as 3-way or 2-way normally open or normally closed and may be used for vacuum, divertor, or selector applications. Extremely high cycle rate capability. Use on lube or non-lube service. Manual overrides as standard. Various solenoid enclosures and plug-in connectors. Optional surge suppression available. Low wattage DC solenoids down to 1.3 watts. Rectified C voltage P ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 79 Consult Precautions page 327 before use, installation or service of MC Valves..

2 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series 4/2 1/8 - # C v Inline OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # SOLENOID OPERTOR Without flow controls 46-1-J XXX-XXX 46-1-J XXX-XXX Single Operator With flow controls 46-2-J XXX-XXX 46-2-J XXX-XXX Without flow controls J XXX-XXX * (-G) dd G for ground 46-G1-J XXX-XXX 46-G1-J XXX-XXX Double Operator With flow controls 46-G2-J XXX-XXX 46-G2-J XXX-XXX P XX Voltage X Wire length X Manual operator XX Single & double solenoid ** O No leads 1 Non-locking recessed 120 VC (5.4W) 18 2 Locking recessed G D 24 VDC (5.4W) 24 GG D 12 VDC (5.4W) C 36 Single solenoid only J DC 24 VDC (2.4W) JD DD 12 VDC (2.4W) K * Other options available, see page 317. KD ** Use with rectangular and mini connectors Note : - C voltage requires connector with rectifier. - With the MC JC, washdown capability is possible. Consult factory for washdown modification number. Double solenoid requires minimum 5.4 watts. Examples : OPTIONS 46-1-JXXX-XXX G Use with O ring mount (body option D & H ) Single operator - 4 port body with side ports C Single operator - 4 port body with bottom ports (No side ports M5 or #10-32 ONLY) D Single operator - ottom O ring mount ll ports (No side ports) F Single operator - ottom O ring mount Cylinder ports only Side inlet & exhaust G Double operator - 4 Port body - With side ports H Double operator - ottom O ring mount - ll ports (No side ports) 46-DG1-Jxxx-xxx (ottom O ring mount all ports) 46-C1-Jxxx-xxx (4 port body with bottom ports no side ports) Electrical connection Flying leads MC JC solenoid plug-in MC JC solenoid plug-in with rectifier Rectangular connector Rectangular connector with light Mini square connector Mini square connector with light ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 81 Consult Precautions page 327 before use, installation or service of MC Valves..

3 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 3,3 mm 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Class wire (#22 WG x 18), continuous duty -15% to +10% of nominal voltage Consult factory 5.4W 2.4W 1.8W Options : SPP threads DIMENSIONS Dimensions shown are metric (mm) Single solenoid Double solenoid 26.5 w/flow CONTROLS w/o FLOW CONTROLS EX EX /8" PORTS DI Ø 3.4 (2) Consult Precautions page 327 before use, installation or service of MC Valves..

4 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold Mounting Series 4/2 1/8 - # C v Stacking OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # SOLENOID OPERTOR Without flow controls 46-S1-J XXX-XXX 46-S1-J XXX-XXX With flow controls 46-S2-J XXX-XXX 46-S2-J XXX-XXX J XXX-XXX * (-G) dd G for ground XX Voltage X Wire length X Manual operator XX D D DC DD 120 VC (5.4W) 24 VDC (5.4W) 12 VDC (5.4W) 24 VDC (2.4W) 12 VDC (2.4W) C 36 1 Non-locking recessed 2 Locking recessed * Other options available, see page 317. Note : - C voltage requires connector with rectifier. - With the MC JC, washdown capability is possible. Consult factory for washdown modification number. End plate kit required (port size 1/4") : M G G GG Electrical connection Flying leads MC JC solenoid plug-in MC JC solenoid plug-in with diode MC JC solenoid plug-in with rectifier P ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 83 Consult Precautions page 327 before use, installation or service of MC Valves..

5 - 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Class wire (#22 WG x 18), continuous duty -15% to +10% of nominal voltage Consult factory 5.4W 2.4W 1.8W Energize : 7.20 ms De-energize : 4.20ms Options : Spare parts : SPP threads Inlet isolator : Exhaust isolator : Tie rod (x2) : DIMENSIONS WITH FLOW CONTROLS WITHOUT FLOW CONTROLS Dimensions shown are metric (mm) Ø 5.3 Ø /8" CYLDER PORTS /4" LET ND UST COMMONS Consult Precautions page 327 before use, installation or service of MC Valves..

6 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series 4/2 1/8" - 5/32 O.D. Pressed-in 0.3 C v tube receptacles plug-in OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/32 O.D. Pressed-in tube receptacles SOLENOID OPERTOR Single solenoid Double solenoid 46-L00-00-J XXP-XXX 46-N00-00-J XXP-XXX 46-LS-C-J XXP-XXX 46-NS-L-J XXP-XXX 46-LSF-C-J XXP-XXX 46-NSF-L-J XXP-XXX J XX P-XXX * (-G) dd G for ground P XX Voltage X Manual operator XX Single & double solenoid 1 Non-locking F 120 VC (5,4W) 2 Locking F C 24 VC (5,4W) FG D 24 VDC (5,4W) D 12 VDC (5,4W) Single solenoid only DC 24 VDC (2,4W) DD 12 VDC (2,4W) * Other options available, see page 317. Note : C voltage requires connector with rectifier. Double solenoid requires minimum 5.4 watts. OPTIONS 46-LS-C-JXXP-XXX C Single solenoid - Side cylinder ports L Single & double solenoid - ottom cylinder ports 0 ase only - no valve L Single solenoid - ase mount body M Single solenoid - ase mount body with gage port N Double solenoid - ase mount body P Double solenoid - ase mount body with gage port Electrical connection ase plug-in ase plug-in with diode ase plug-in with rectifier ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 Example : base only : 46-0S-C. End plate kit required (port size 1/4") : M Consult Precautions page 327 before use, installation or service of MC Valves..

7 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orific e Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 3.3 mm 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Epoxy encapsulated Class wires 100% ED -15% to +10% of nominal voltage IP54 (electrical connection) 5.4W 2.4W 1.8W Energize : 7.20 ms De-energize : 4.20ms Options : Spare parts : SPP threads Inlet isolator : Exhaust isolator : Valve cover plate : M Tie rod (x2) : DIMENSIONS Dimensions shown are metric (mm) Double solenoid Ø 4.3 1/4" COMMONS Ø /4"-14 NPSM Consult Precautions page 327 before use, installation or service of MC Valves..

8 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series 4/2 1/8" - 5/32 O.D. Pressed-in 0.3 C v tube receptacles OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERTOR Port size (ottom ports only) Valve less base 1/8 NPTF 5/32 O.D. Pressed-in tube receptacles plug-in with pressure regulators Model number 46-L00-00-J XXP-XXX 46-LS-J-J XXP-XXX 46-LSF-J-J XXP-XXX J XX P-XXX * (-G) dd G for ground P XX Voltage X Manual operator XX 120 VC (5.4W) 1 Non-locking recessed F D 24 VDC (5.4W) 2 Locking recessed F D 12 VDC (5.4W) FG DC 24 VDC (2.4W) * Other options available, see page 317. Note : C voltage requires connector with rectifier. OPTIONS 46-LS-J-JXXP-XXX J Regulator with adjusting knob E Regulator with slotted stem G Regulator with slotted stem with locknut 0 ase only no valve L ase mount body M ase mount body with gage port Example : base only with regulator : 46-0S-J. End plate kit required (port size 1/4") : M Electrical connection ase plug-in ase plug-in with diode ase plug-in with rectifier ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 87 Consult Precautions page 327 before use, installation or service of MC Valves..

9 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Class continuous duty, #22 WG x 12 base leads -15% to +10% of nominal voltage Consult factory 5.4W 2.4W 1.8W Energize : 7.20 ms De-energize : 4.20ms Options : Spare parts : Regulating range options : SPP threads Inlet isolator : Exhaust isolator : Valve cover plate : M Tie rod (x2) : Replacement regulators : PR46-0 (slotted stem) PR46-0 (adjusting knob) PR46-0C (slotted stem with locknut) PR46-xxx 0 to 120 PSI 0 to 80 PSI C 0 to 30 PSI DIMENSIONS Dimensions shown are metric (mm) /8" GGE PORT 69.2 Ø 4.3 1/4" COMMONS /4"-14 NPSM 88 Consult Precautions page 327 before use, installation or service of MC Valves..

10 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series 4/2 1/8" - 5/32 O.D. Pressed-in 0.3 C v tube receptacles plug-in with flow controls OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERTOR Port size Valve less base 1/8 NPTF 5/32 O.D. Pressed-in tube receptacles XX Voltage X Manual operator XX 120 VC (5.4W) 1 Non-locking recessed F D 24 VDC (5.4W) 2 Locking recessed F D 12 VDC (5.4W) FG DC 24 VDC (2.4W) * Other options available, see page 317. Note : C voltage requires connector with rectifier. OPTIONS 46-LS-D-JXXP-XXX D Side cylinder ports M ottom cylinder ports 0 ase only no valve L ase mount body M ase mount body with gage port Example : base only with flow controls: 46-0S-D. End plate kit required (port size 1/4") : M Model number 46-L00-00-J XXP-XXX 46-LS-D-J XXP-XXX 46-LSF-D-J XXP-XXX J XX P-XXX * (-G) dd G for ground Electrical connection ase plug-in ase plug-in with diode ase plug-in with rectifier P ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 89 Consult Precautions page 327 before use, installation or service of MC Valves..

11 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Class continuous duty, #22 WG x 12 base leads -15% to +10% of nominal voltage Consult factory 5.4W 2.4W 1.8W Energize : 7.20 ms De-energize : 4.20ms Options : Spare parts : SPP threads Inlet isolator : Exhaust isolator : Valve cover plate : M Tie rod (x2) : DIMENSIONS Dimensions shown are metric (mm) Ø /4" COMMONS /4"-14 NPSM 90 Consult Precautions page 327 before use, installation or service of MC Valves..

12 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series 4/2 1/8" - 5/32 O.D. Pressed-in 0.3 C v tube receptacles plug-in with PR & FC OPERTIONL ENEFITS 1. alanced poppet, immune to variations of pressure. 2. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERTOR Port size (ottom ports only) Valve less base 1/8 NPTF 5/32 O.D. Pressed-in tube receptacles XX Voltage X Manual operator XX 120 VC (5.4W) 1 Non-locking recessed F D 24 VDC (5.4W) 2 Locking recessed F D 12 VDC (5.4W) FG DC 24 VDC (2.4W) * Other options available, see page 317. Note : C voltage requires connector with rectifier. OPTIONS 46-LS-K-JXXP-XXX K Regulator with adjusting knob & flow controls F Regulator with slotted stem & flow controls H Regulator with slotted stem with locknut & flow controls 0 ase only no valve L ase mount body M ase mount body with gage port Example : base only with regulator : 46-0S-K. End plate kit required (port size 1/4") : M Model number 46-L00-00-J XXP-XXX 46-LS-K-J XXP-XXX 46-LSF-K-J XXP-XXX J XX P-XXX * (-G) dd G for ground Electrical connection ase plug-in ase plug-in with diode ase plug-in with rectifier P ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 91 Consult Precautions page 327 before use, installation or service of MC Valves..

13 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 100 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1.8W : (0.20 C v ) 2.4W : (0.20 C v ) 5.4W : (0.30 C v ) Class continuous duty, #22 WG x 12 base leads -15% to +10% of nominal voltage Consult factory 5.4W 2.4W 1.8W Energize : 7.20 ms De-energize : 4.20ms Options : Spare parts : Regulating range options : SPP threads Inlet isolator : Exhaust isolator : Valve cover plate : M Tie rod (x2) : Replacement regulators : PR46-0 (slotted stem) PR46-0 (adjusting knob) PR46-0C (slotted stem with locknut) PR46-xxx 0 to 120 PSI 0 to 80 PSI C 0 to 30 PSI DIMENSIONS Dimensions shown are metric (mm) /8" GGE PORT 69.2 Ø 4.3 1/4" COMMONS /4"-14 NPSM 92 Consult Precautions page 327 before use, installation or service of MC Valves..

14 OPTIONS Codification table for voltages / Manual operators / Electrical connections VLVE CODE J XX X-X XX OPTIONS VILLE FOR - Solenoid valves 36, 46, ISO 01 and ISO 02 Series 317 Consult Precautions page 327 before use, installation or service of MC Valves..

15 OPTIONS 1. VOLTGE J-XX X-X XX VOLTGE 120VC (5.4W) C 24VC (5.4W) DE 24VDC (1.8W) DF 12VDC (1.8W) DJ 24VDC (1.3W) DL 12VDC (1.3W) DN 12VDC (0.5W)* DR 12VDC (1.0W)* DS 24VDC (0.5W)* DU 24VDC (1.0W)* * Not available on 36 series universal valve J-XX X-X XX C D E F P O 2. WIRE LENGTH WIRE LENGTH 18" coil leads 24" coil leads 36" coil leads 48" coil leads 72" coil leads 96" coil leads ase plug-in No leads (use with J, K & L type connectors) 3. MNUL OPERTOR J-XX X-X XX MNUL OPERTOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended J-XX X-X XX G G GC GD GE GF GG GH GJ GK GL GM GN GP GR GS *J *JC *JE *JF *JG *JH *JK 4. ELECTRICL CONNECTION CONNECTORS FOR NON PLUG- VLVES ELECTRICL CONNECTION Flying leads MC JC solenoid plug-in MC JC solenoid plug-in with diode MC JC solenoid plug-in with MOV MC JC solenoid plug-in with light MC JC solenoid plug-in with diode and light MC JC solenoid plug-in with MOV and light MC JC solenoid plug-in with rectifier MC JC solenoid plug-in with rectifier and light MC JC solenoid plug-in Male only MC JC solenoid plug-in with diode Male only MC JC solenoid plug-in with MOV Male only MC JC solenoid plug-in with light Male only MC JC solenoid plug-in with diode and light Male only MC JC solenoid plug-in with MOV and light Male only MC JC solenoid plug-in with rectifier Male only MC JC solenoid plug-in with rectifier and light Male only Square Connector Square Connector with light Square Connector with diode Square Connector with MOV Square Connector with diode/light Square Connector with MOV/light Square Connector with Rectifier J-XX X-X XX *JL Square Connector with Rectifier with light *JJ Square Connector Male only (Plain) *J Rectangular Connector *JD Rectangular Connector with light *JN Rectangular Connector with diode *JP Rectangular Connector with MOV *JR Rectangular Connector with diode/light *JS Rectangular Connector with MOV/light *JT Rectangular Connector with Rectifier *JU Rectangular Connector with Rectifier with light *JM Rectangular Connector Male only (Plain) * Not available on manifold or stacking valves J-XX X-X XX K K KC KD KE KF KG KH KJ KK KL KM KN KP KR KS J-XX X-X XX L L LC LD LE LF LG LH LJ LK LL LM LN LP LR LS J-XX X-X XX F F FC FD FE FF FG FH CONNECTORS FOR NON PLUG- VLVES MI SQURE PLUG- CONNECTORS 9.4 MM SPCG ETWEEN PS Mini plug-in Mini plug-in with diode Mini plug-in with MOV Mini plug-in with light Mini plug-in with diode and light Mini plug-in with MOV and light Mini plug-in with rectifier Mini plug-in with rectifier and light Mini plug-in Male only Mini plug-in with diode - Male only Mini plug-in with MOV - Male only Mini plug-in with light - Male only Mini plug-in with diode and light Male only Mini plug-in with MOV and light Male only Mini plug-in with rectifier Male only Mini plug-in with rectifier and light Male only CONNECTORS FOR NON PLUG- VLVES MI SQURE PLUG- CONNECTORS 8.0 MM SPCG ETWEEN PS ISO SPECIFICTION Mini plug-in Mini plug-in with diode Mini plug-in with MOV Mini plug-in with light Mini plug-in with diode and light Mini plug-in with MOV and light Mini plug-in with rectifier Mini plug-in with rectifier and light Mini plug-in Male only Mini plug-in with diode - Male only Mini plug-in with MOV - Male only Mini plug-in with light - Male only Mini plug-in with diode and light Male only Mini plug-in with MOV and light Male only Mini plug-in with rectifier Male only Mini plug-in with rectifier and light Male only CONNECTORS FOR PLUG- VLVES ase plug-in ase plug-in with diode ase plug-in with MOV ase plug-in with light ase plug-in with diode and light ase plug-in with MOV and light ase plug-in with rectifier ase plug-in with rectifier and light 318 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin Manifold mounting Stacking Manifold base plug-in Manifold base plug-in

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Air return 33 34 36 3 37 38 5 67 69 44 46 4 47 48P SERIES

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves SIZE 26 mm Individual mounting Valve only No base non plug-in Conform to ISO 15407/1 Manifold mounting Valve only No base non plug-in Conform to ISO 15407/1

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline sub-base non plug-in Manifold mounting 35 stacking sub-base non plug-in sub-base with pressure regulators sub-base with

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in Sub-base plug-in Manifold mounting Sub-base non plug-in Sub-base plug-in 33 34 36 32 onded spool

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series non plug-in plug-in Manifold mounting 35 non plug-in plug-in 100 Pilot air accumulator ir/spring return Integral ground wire

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves 8mm valve Series 33 Function Port size Flow (Max) Individual mounting Series 3/ NC M3 0.08 C v Inline OPERATIONAL BENEFITS 1. 8mm valve direct solenoid

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in 4 6 Air return Manual operator Solenoid 4-way pilot with balanced poppet Bonded spool 2 7 8 2 67

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Inlet (1) Exhaust (3) Cylinder () 33 34 36 3 37 38 5 67 69

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline inline hazardous location Manifold mounting 35 sub-base non plug-in sub-base with pressure regulators sub-base hazardous

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in sub-base with pressure regulators 100 200 1 55 56 57 58 59 Manual

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/ Manifold mounting Valve

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Manual operator Solenoid Individual mounting Sub-base non Sub-base Manifold mounting Manifold base Sub-base/ manifold base non with latching solenoid

More information

MAC VALVES EUROPE, INC.

MAC VALVES EUROPE, INC. CURRENT Technology Page Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 165 Mechanically and manually operated

More information

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 NEW Technology Page Introduction Section 1 Section Section Section 4 Section 5 Section 6 Section 7 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 197 Bases according to ISO 5599

More information

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX Patents and Patents Pending SMALL 3 WAY SOLENOID, AIR AND MECHANICALLY OPERATED VALVES MANUAL OPERATOR COIL SOLENOID STROKE (GAP) PUSH PIN POLE PIECE POLE PIECE SPRING The 34 series is a direct operated

More information

Specifications 54 Series Valve

Specifications 54 Series Valve Specifications 54 Series Valve Fluids: Compressed Air or Inert Gases Lubrication: Not required. If used, select a medium aniline point lubricant (between 180ºF and 210ºF) Safe Operating Temperature Range:

More information

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77 Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Individual mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting

More information

32, CONTENTS SMALL LARGE

32, CONTENTS SMALL LARGE SMALL 11,2 LARGE 3-WAY VALVES - 2 to 32 Introduction 02-03 33 Series 04 34 Series 05-06 35 Series 07-08 36 Series 09-12 37 Series 13-14 100 Series 15 200 Series 16 1100 Series 17 Introduction 18-19 52

More information

Bullet Valve (BV) Series

Bullet Valve (BV) Series ullet Valve (V) Series VERY FEW PARTS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / ARMATURE ALANCED DESIGN SOLENOID ISOLATED FROM CONTAMINATED AIR UNIQUE MOUNTING D-SEAL TECHNOLOGY LONG LIFE LIFTING SOLENOID

More information

42 Series MAConnect TM. 42 Series Plug-In Manifold

42 Series MAConnect TM. 42 Series Plug-In Manifold 42 Series MAConnect TM 42 Series Plug-In Manifold Specifications 42 Series Valve Operating Data Fluids: Lubrication: Safe Operating Temperature Range: Pressure Range: Electrical: Air or Inert Gas Not Required.

More information

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural 1 SERI ISO-A Manufactured according ISO 7241-A norm, size meets also ISO 5675 requirements. Poppet Valve or Ball closing system. BSP, NPTF, SAE/ORB threads. Others available upon request. Materials Body:

More information

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP We are pleased to announce the release and availability of the MI/O-67 Fieldbus Platform. Our initial release includes several different protocol options in addition to several modules to ensure a complete

More information

MAC VALVES, INC. Rev. T

MAC VALVES, INC. Rev. T REVISION LEVEL DATE RELEASED CHANGE DESCRIPTION ECN NUMBER P.E. APPROVAL P.D APPROVAL A 5-11-95 ENGINEERING RELEASE 12727 EPJ B 1-15-96 ADDED 35 SERIES 13228 EPJ ADDED MOD 2938 TO 6500 SERIES, MODS 2910

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk

More information

Bullet Valve (BV) Series

Bullet Valve (BV) Series BULLET Valve Bullet Valve (BV) Series The Bullet Valve represents yet another evolution in air valve technology from MAC. VERY FEW PARTS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / ARMATURE (Patents

More information

92 Series MAConnect with Sub D

92 Series MAConnect with Sub D 9 Series MAConnect with Sub D MAXIMUM OF 0 SOLENOIDS CAN BE POWERED BY A SINGLE MULTI-PIN CONNECTOR. UP TO 40 SOLENOIDS CAN BE POWERED BY MEANS OF A SECOND MULTI-PIN CONNECTOR STATION. LEFT OR RIGHT END

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

82 Series MAConnect with Sub-D

82 Series MAConnect with Sub-D 82 Series MAConnect with Sub-D Maximum of 20 solenoids can be powered by a single multi-pin connector. Up to 40 solenoids can be powered by means of a second multi-pin connector station. Left or right

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

MAC Pulse Valve PV06 Series

MAC Pulse Valve PV06 Series The MAC Pulse Valve series is designed to be a direct drop-in replacement for existing pulse technology. The MAC solution utilizes a long life, bonded-spool design, instead of the traditional diaphragm

More information

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI CFR Series Coils, Transformers OUTLINE Power inductors for preventing the diffusion of noises generated from power circuits and suppressing noise components coming through the power lines. ø8.7 ø11 max.

More information

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right How to Order 93 Series MAConnect 93 A - X X X - X X X - XX - D XX P - X XX Pilot Valve Options (see below) Valve Function 0 Base Only A Sgl. Oper. Sgl. Press. B Dbl. Oper. Sgl. Press. C Sgl. Oper. Dual

More information

MAC Pulse Valve PV03 Series

MAC Pulse Valve PV03 Series The MAC Pulse Valve series is designed to be a direct drop-in replacement for existing pulse technology. The MAC solution utilizes a long life, bonded-spool design, instead of the traditional diaphragm

More information

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves Sc h rader Bellows 2 & 3-Way, Inline, Manifold & Stacking Direct cting Solenoid Valves INDEX PGE Features Inline Valves... 3 Stacking Valves... 4 Manifold Valves... 5 Valve Model Number System... 6 Solenoid

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. CERAMIC CHIP CAPACITORS C0G (NP0), X7R, X5R, Z5U and Y5V Dielectrics 10,

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Table 1d - FSA for All Returns, Females Tax Year

Table 1d - FSA for All Returns, Females Tax Year PR 10 Newfoundland and Labrador A0A 20,250 597,345 1,920 1,720 2,580 3,150 1,960 1,610 1,360 1,030 1,020 740 550 460 630 470 410 290 290 70 20 A0B 8,850 249,804 780 740 1,200 1,520 1,010 790 540 430 370

More information

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals. 8 SERIES /8 Ported Air Valves 1/ Ported Air Valves /8 & 1/ 1, 1A, 1B & 8 Series Note! Spring return & spring centered models NOT suitable for dry air service. Features & Way - Position. Way - &. operator

More information

503 Series Solenoid Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves Offered by: Specialists in Valves, ontrols, Pneumatics, Fluid Measurement Phone: (203) 261-6711 www.okcautomation.com 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

and zero rpm. Maximum recommended pressure is 110 psi (7.6 bar). Adjustment for speed is explained under Selection Procedure.

and zero rpm. Maximum recommended pressure is 110 psi (7.6 bar). Adjustment for speed is explained under Selection Procedure. CB Construction Single Flange Dual Flange The type CB element assembly is designed and built to provide dependable clutch or brake service in the most exacting industrial applications. It is suited to

More information

Seated valves 500 bar

Seated valves 500 bar Seated valves 500 bar Type WVM-6I Features Solenoid actuated and direct operated Leakage free in every direction (double tight) High operational safety and reliable switching High duty cycles and long

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI) Gear Pump High Performance Version GP3 up to cm 3 (6. inch 3 ) p max 32 bar (46 PSI) Speed from 35 to 32 RPM Technical Features Operating pressure 29 bar, Peak pressure 32 bar High-strength quality aluminum

More information

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves www.humphrey-products.com Humphrey Products Company P.O. Box 008 Kalamazoo, MI 4900 USA P.69.8.5500 F.69.8.4 BVSa-07 A privately owned

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. CERAMIC CHIP CAPACITORS C0G (NP0), X7R, X5R, Z5U and Y5V Dielectrics 10,

More information

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities 501 Series irectional ontrol Valve Platform Featuring Higher Flow in a ompact Valve Package ommissioning apabilities Solenoid air pilot actuated Low wattage.8 wall for application solenoids Polarity insensitive

More information

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

VAL /4 to 2 Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking 1/4" to 2" Solenoid Pilot ctuated VLVES High flow - Cv of 1.2 to 49.5 Durable, robust construction 1/4" to 2" ports (SPP, PTF, or ISO Rc threads) Wide range of voltages available Four functional types:

More information

Airflex CB Construction Section B

Airflex CB Construction Section B Airflex CB Construction Single Flange Element Dual Flange Element The type CB element assembly is designed and built to provide dependable clutch or brake service in the most exacting industrial applications.

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact: Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,

More information

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI) Gear Pump High Performance Version GP3 up to 1 cm 3 (6.1 inch 3 ) p max 3 (46 PSI) Speed from 35 to 32 RPM Technical Features Operating pressure 29 bar, Peak pressure 3 High-strength quality aluminum alloys

More information

COILS DELTA POWER COMPANY

COILS DELTA POWER COMPANY COILS COMPANY Section / Description page COIL DATA... CD3 IMMERSION PROOF... CD16 GENERAL CARTRIDGE VALVE INSTALLATION NOTES... CD19 CAD INSERTION CODES - 2D... CD20 CAD INSERTION CODES - 3D... CD22 Page

More information

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication ROSS CONTROLS Base Mounted Valves and Serial Bus Communication ISO 15407-1 & 2 ISO 5599/I & /II Serial Communications VLVE TYPE NSI SE Miniature 14 Series Solenoid Pilot Valves Pack VLVE SERIES DESCRIPTION

More information

Series MI-01, MI-02, MI-03

Series MI-01, MI-02, MI-03 Valves > standardized valves > electrically operated > Series MI-01, MI-02, MI-03 ISO 99/1, Size 1 to 3 Technical details Series Connection MI-01, MI-02, MI-03 ISO 99/1 Nominal size Temperature range Medium

More information

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector 1/4" to 2" Solenoid Pilot ctuated VLVES High flow - Cv of 1.2 to 49.5 Durable, robust construction 1/4" to 2" ports (SPP, PTF, or ISO Rc threads) Wide range of voltages available Four functional types:

More information

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6 Table of Contents Minature Valve Series...3-14 RB Series...3-6 Technical Data.... 3 How to Order.... 4 Dimensions... 5 Inline Mount Valve.... 6 Manifold Dimensions and Part Numbers... 6 S Series...7-9

More information

Electrically operated spool valve. The manual override is detent and is operated by screw driver.

Electrically operated spool valve. The manual override is detent and is operated by screw driver. Valves > electrically operated valves > Series M-07 Technical details Connection G1/ Nominal size Temperature range Medium Series M-07 page Materials 9 mm -10 C... +70 C Filtered, oil-free and dried compressed

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

DYNA-POWER LUBRICATION

DYNA-POWER LUBRICATION DYN-POWER LURICTION D-0-09- Lubrication ccessories July 2007 division of Dyna-Power Engineers,Inc. 5330 Greenwood ve South olland, IL 60473 LURICTION CCESSORIES Table of Contents Grease / Oil Guns 2 Grease

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Constricting Type Clutches and Brakes

Constricting Type Clutches and Brakes Constricting Type Clutches and Brakes B Constricting Features B-1 Element Descriptions B-3 CB Elements B-5 Technical and Dimensional Data B-9 Clutch and Brake Applications B-15 Mounting Components B-40

More information

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications 8 SERIES: /8 Ported Air Valves, A & B SERIES: / Ported Air Valves /8 & /, A, B & 8 Series, & Way; & Position Operation to 50 psi Note! Spring return & spring centered models NOT suitable for dry air service.

More information

Genesis Series Valves Parts List / Service Instructions

Genesis Series Valves Parts List / Service Instructions Genesis Series Valves Parts List / Service Instructions INDEX PAGE General Warnings and Cautions......................................................... 2 Model Number Index...................................................................

More information

CYLINDER HEAD. Ref. Part No. Number Description Qty Remarks

CYLINDER HEAD. Ref. Part No. Number Description Qty Remarks A1 CYLINDER HEAD 1 JN6-11102-00-00 HEAD, CYLINDER.......... 1 2 JN6-11133-10-00. GUIDE, VALVE............ 2 3 JN6-11181-00-00 GASKET, CYLINDER HEAD... 1 4 95817-10070-00 BOLT, FLANGE............ 4 5 99530-14016-00

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

INSTRUMENT PANEL CLUSTERS

INSTRUMENT PANEL CLUSTERS INSTRUMENT PANEL CLUSTERS NOT BUYING AT THIS TIME REVISED ##### PART # MAKE APPLICATION 6/18/2018 PRICE 56045618 CHRY IPC 40.00 56045679 CHRY IPC 40.00 56051103 CHRY IPC 40.00 56049833 AC,AD CHRY IPC 40.00

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Flow Measurement SITRANS F S Clamp-on

Flow Measurement SITRANS F S Clamp-on Clamp-on ultrasonic flowmeters Overview SITRANS F S clamp-on ultrasonic flowmeters provide highly accurate measurement while minimizing installation time and maintenance expense. Benefits Easy installation;

More information

Bulletin 14CAN Specialty & Control Valves

Bulletin 14CAN Specialty & Control Valves Bulletin 14C 4-7-06 Specialty & Control Valves Composite Solenoid Valve, 2 & 3-Way ormally Closed or ormally Open Series 38MP The Series 38MP is a 3 or 2 way, 2 position composite body solenoid valve designed

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

TELESCOPIC CYLINDERS ø mm Series RT

TELESCOPIC CYLINDERS ø mm Series RT TELESCOPIC CYLINDERS 25 63 mm Series RT The overall dimensions are one of the most imporant aspects: in comparison with a traditional ISO cylinder of the same a reduction in size of approx. 45% (with a

More information

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004 Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves Catalog VAL-VS-E/USA April 2004 ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369 and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting

More information

PILOT OPERATED SEQUENCE VALVE - Series VR4S

PILOT OPERATED SEQUENCE VALVE - Series VR4S PILOT OPERTED SEQUENCE VLVE - Series VRS Veljan Sequence Valve Series VRS are pilot operated controls and enable a hydraulic system to operate a sequence. Fluid is allowed to pass to a secondary system

More information

Multiplication Tables of Various Bases

Multiplication Tables of Various Bases THE NUMBER BASE 10 100 Ternary (Base 3) 1 2 10 2 11 20 10 20 100 Quaternary (Base 4) 1 2 3 10 2 10 12 20 3 12 21 30 10 20 30 100 Quinary (Base 5) 1 2 3 4 10 2 4 11 13 20 3 11 14 22 30 4 13 22 31 40 10

More information

SMA6J5.0A(CA) - SMA6J440A(CA)

SMA6J5.0A(CA) - SMA6J440A(CA) SMA6J5.0A(CA) - SMA6J440A(CA) SURFACE MOUNT TRANSIENT VOLAGE SUPPESSOR DIODE VOLTAGE RANGE: 5.0-440 V POWER: 600Wa t t s Features Glass Passivated Die Construction Uni- and Bi-Directional Versions Available

More information

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves www.humphrey-products.com Humphrey Products Company P.O. Box 008 Kalamazoo, MI 4900 USA P.69.8.5500 F.69.8.4 BVS-05 A privately owned US

More information

Flow Measurement SITRANS F S Clamp-on

Flow Measurement SITRANS F S Clamp-on Clamp-on ultrasonic flowmeters SITRANS FS20 Overview SITRANS F S clamp-on ultrasonic flowmeters provide highly accurate measurement while minimizing installation time and maintenance expense. Benefits

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

NAMUR Technical details

NAMUR Technical details Valves > standardized valves > electrically operated > Series KN-0, KN- NAMUR Technical details Connection Nominal size Series KN-0, KN- Temperature range Medium G1/4, Namur 6 mm -10 C... +70 C Filtered,

More information

CORE RETURN REQUIREMENTS

CORE RETURN REQUIREMENTS RACK & PINION STEERING GEAR Type A SPR Code Located On Valve End Of Valve SPR Code 1. Cross reference part number on box to SPR 3. Match code found on part to SPR Codes obtained from SPR Code Identification

More information

2005 Series Solenoid Pilot Actuated Valves

2005 Series Solenoid Pilot Actuated Valves Series Solenoid Pilot ctuated Valves www.numatics.com Table of Contents 2005 Series Terminal Strip, Sub-D, and 26 & 12 Round Pin Options-Exploded View 3 Technical and Operating Data 4 How to Order 5 Individual

More information

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale) Version 1.0 Grade boundaries June 2018 exams GCSE Reformed (subjects which use the 9 to 1 grade scale) This document presents grade boundaries for the new reformed GCSEs which use the 9 to 1 grade scale.

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style Genuine Metaris Gear Product Technical Catalog Pumps & Components - MH Series Bearing & Bushing Style www.metaris.com MH365 Series Bushing Pump Features Metaris Bushing Pumps & Motors are available in

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9 Miniature Valve Series............................................................3-14 RB Series..................................................................................3-6 Technical Data...................................................................................3

More information

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic Section irect Acting Valves - irect Acting Pictorial Index - www.parker.com/pneu/valve Inline continued N - Inline Poppet Inline or stacking /8 inch ports Pressures 0 to 5 PSIG Temperatures F to 5 F Flow

More information

2/2, 3/2 and 4/2 directional poppet valve with solenoid actuation

2/2, 3/2 and 4/2 directional poppet valve with solenoid actuation 0/0 /, / nd / directionl poppet vlve with solenoid ctution.7 Type M-.SEW...LX Size Up to 0 r Up to 0 L/min Contents Function nd configurtion Symols 0 Specifiction 0 Technicl dt 0 Electricl dt 0 Chrcteristic

More information

ISO 5599/ Series Technical and Operating Data

ISO 5599/ Series Technical and Operating Data ISO 5599/ Series...................................................................3-9 Technical and Operating Data......................................................................3- How to Order...................................................................................5-6

More information

SECTIONAL BODY. Series 20. Directional Control Valves STANDARD FEATURES SPECIFICATIONS VALVES. Pressure Rating

SECTIONAL BODY. Series 20. Directional Control Valves STANDARD FEATURES SPECIFICATIONS VALVES. Pressure Rating Directional Control Valves SECTIONAL BODY Series 20 CATV 3-10-11-01 STANDARD FEATURES SPECIFICATIONS Parallel or Tandem Circuit Foot Mounting Pressure Rating Weight............... Nominal Flow Rating...

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information