AGM. I-Lux MR 16 Style 2 & 5, Coil & Shunt. 108 Fairgrounds Drive Suite 8 Manlius, NY Phone: Fax:
|
|
- Magdalen Joseph
- 6 years ago
- Views:
Transcription
1 AGM I-Lux MR 16 Style 2 & 5, Coil & Shunt
2 Revision 7.5 Pg 2
3 I-Lux Catalog / Item Numbers Catalog Code XXX.XXF Sign Size 1 ~ Size 1 2 ~ Size 2 3 ~ Size 3 5 ~ Size 5 Sign Style 2 ~ Style 2 (3 step 4.8A - 6.6A) 5 ~ Style 5 (1 step 5.5A) Sign Faces S ~ Single Face D ~ Double Face Modules 1.0 to 4.0 in length L830 Requirements / Power Factor / VA Loads Size Number of Modules L830 Transformer Style 2 / Style 5 Power Factor Volt Amp - VA Load Style 2 / Style 5 Number of Lamps All / / / 68 1 All / / / All / / / All / / All / / All / / All / These ratings are subject to improvement without notice.
4
5 Panel Dimensions Sign Size Legend Size Viewable Panel Height Overall Sign Height Face Height & /8 19 7/8 25 7/ Size 1 Size MOD 1.0 MOD Size 4 Size MOD
6 I-Lux Installation 1. Place the sign on the pad with the floor flanges perpendicular to the length of the sign. 2. Mark mounting locations. 3. Move the sign out of the way. 4. Drill mounting holes for anchor bolts. 5. Install L-830 transformer into the base can. Check technical data sheet to make sure correct wattage is used. 6. Secure cable clamp to transformer secondary lead or secondary extension cord. 7. Reposition the sign on the pad and hold at an angle. 8. Pull the power cord out of the leg of the sign, plug it into the transformer secondary lead or extension cord. 9. Rotate the sign to the upright position over the anchor holes being careful to not pinch the power cord. 10.Loosely clamp flanges to the pad. 11.Loosen the pinch bolts in the slip flanges. 12.Tighten the anchors on the floor flanges. 13.Tighten the pinch bolts in the slip flanges against the couplings. All AGM signs have been tested at the factory and set to function within FAA specifications immediately upon installation. Just plug it in, bolt it down and walk away. Installation issues are almost always traced back to an incorrect isolation transformer or potential damage occurring in shipping or storage. Make sure to note any damage that occurred in shipping when receiving the signs and be sure to document it with the carrier. When installing the sign make sure that the correct L830 isolation transformer is connected. I-Lux Maintenance AGM signs are designed to provide decades of trouble-free service. Prior to the performance of any work on the signs, power should be disconnected either at the vault or through use of the sign s power switch (if so equipped). We recommend an annual inspection & wiping down of the sign interior to maintain bright and even light output. Inspection of the signs should also include removal of any excess dirt, snow, and avian excrement to maintain proper visibility of the sign legend. I-Lux Installation Troubleshooting All AGM signs have been tested at the factory and set to function within FAA specifications immediately upon installation. Just install and walk away. Installation issues are almost always traced back to a failed lamp or an undersized isolation transformer. Further information on opening the I-Lux cabinet and troubleshooting the Coil & Shunt PCM follows on page 8. If the lamps and isolation transformer appear functional, and any operating issues have not been resolved after following the troubleshooting guidelines, please call us at and we will be pleased to assist you.
7 I-Lux Warranty Warranty AGM L858(L) Airfield Guidance Signs are warranted against mechanical and physical defects in design or manufacture for a period of 2 years from date of installation per FAA AC 150/ (applicable edition), and against electrical defects in design or manufacture of the LED or LED specific circuitry for a period of 4 years per FAA EB67(applicable edition), and will correct such by repair or replacement, at its option, provided the signs have been properly handled and stored prior to installation, properly installed and operated after installation, and provided further that the Buyer has notified AGM in writing within the warranty period and a reasonable time after notice of such defects. Refer to handling, storage, installation and operational instructions for proper procedural guidance that must be followed to maintain warranty provisions. This warranty is in effect for the specified term as long as the L-858(L) equipment: has not been, in AGM's judgment, altered in such a way as to affect the equipment adversely, subject to accident, negligence, improper storage, and has been operated and maintained in accordance with accepted FAA guidelines as describe in AC 150/ (applicable edition) and AGM's published operational guidelines. AGM reserves the right to examine signs on which a claim has been made. Equipment must be presented in the same condition as when the defect was discovered. AGM also reserves the right to require the return of equipment to establish any claim. Disclaimer: AGM's obligation under this warranty is limited to repair or replacement of defective equipment sold by AGM at no cost to Buyer. This does not include any other costs such as the cost of removal, shipping, or installation of the defective part or repaired product, including labor or any consequential damages of any kind. Warranty services provided under this agreement does not assure uninterrupted operations of L- 858(L) equipment. AGM shall not be liable for any indirect or consequential damages. AGM's liability under no circumstances will exceed its sales price of the signs claimed to be defective. All transportation costs under this warranty are the responsibility of the purchaser. Replacement parts and or equipment provided under this warranty are covered under the same terms until the expiration of the original warranty period that began upon the first installation of the equipment. This is AGM's sole and exclusive warranty with respect to the L-858(L) equipment sold to the Buyer. There are no express or implied warranties of fitness for any particular purpose or any implied warranties other than those made expressly herein. AGM shall not be liable to the purchaser of this product or third parties for indirect or consequential damages, or for damages arising from the use of any options or parts other than those designated by AGM as approved products. Damage caused by lightning, flood and other natural or man made causes are outside the scope of this warranty.
8 I-Lux Field Trouble Shooting If your I-Lux requires attention, we are pleased to assist you at We keep all parts in stock and ship within 24 hours. Lamp failure is by far the most common reason your sign will not illuminate. The FAA requires all signs to be wired in series so that when one lamp fails, the whole sign goes dark. Ensure that power to the sign has been turned off, and examine each lamp for continuity. Sometimes the filament in a failed lamp will appear intact and the continuity check is the easiest way to ensure a speedy lamp change. While doing this, it is suggested that you examine each lamp socket for any worn or loose connections. If all lamps and sockets appear in good order, remove the end of the sign to gain access to the Power Control Module (PCM). Remove the two lamp circuit ends from the terminal block and check for continuity through the lamp circuit. Check all connections on the PCM to make sure they are tight. If all connections are tight, there is continuity through the lamp circuit and the sign will not illuminate, then the voltage regulator may need replacing. To check this, remove the wire from the terminal on the regulator that is marked Shunt. Energize the circuit to step 1. If the regulator shunt has malfunctioned, the lamps will illuminate. Do not continue to operate the sign with the shunt removed as any increase in circuit amperage will cause the lamps to get too much power and burn out. Replace the shunt (part #24) to resume normal operation. If you do not have a replacement shunt contact AGM to have a replacement shipped out immediately. If the sign illuminates but appears dim, follow the shunt adjustment procedure on the next page. If the voltage on step one is too low and there is a pulsation observed in the middle current steps, then the size of the associated L-830 transformer can be increased by one size. This can be necessary on circuits that are approaching the maximum rated load of the L-828 regulator. I-Lux PCM Access 1.) Remove the bolts (7/16 socket) from the top and bottom surface of the power end. 2.) Slide the side out. 3.) Sign panel may be removed if greater access is desired.
9 I-Lux Coil & Shunt Adjustment To adjust the voltage regulation shunt on the I-Lux, remove the lamp cap on the end of the sign closest to the power leg. Using a true RMS meter, insert the leads into the open butt connectors beside the lamp. Energize the airfield circuit to the top step 6.6A and take note of the voltage value on the meter. Shunt adjustment hole Shunt adjustment hole plug The proper operating voltage is between 11.5VAC and 12.0VAC. We recommend operating at or below 11.75V to extend lamp life and avoid frequent relamping. If the voltage needs to be adjusted, remove the shunt adjustment plug on the side of the sign closest to the power leg. There is a small slotted adjustment screw on the right side of the voltage regulator shunt (magnified in the image below) that when turned clockwise, will increase the voltage, and likewise counter-clockwise will decrease the voltage. The shunt adjustment tool in your installation kit is an effective tool to accomplish this. A 3/32 flat head screwdriver is also effective in adjusting the shunt.
10 Floor Flange Dimensions
11 AGM A B C D E F J I H G K L Q P M O N I-Lux Style 2, & 5, MR 16 Coil & Shunt Part List Part # Description J I7-SH24 Shunt MR 16 Socket K I7-PCM * Power Control Module. I7-9Q MR 16 Lamp L I-CBN Corner Bracket with knurl nut D I7-LHS Lamp Holder with Heatsink M C6-THR Tether E I7-LCG Lamp Cap Gasket N C7-36PC Power Cord F I8-#LP00 Panel, 0.0 is sign length. O C6-FF235 Floor Flange G I7-#LB Light Baffle P I6-FC# Frangible Coupling H I6-#SP Support Post, (only size 2 or 3) Q C6-SF5 Slip Flange I I6-CB Corner Bracket C9-INP Name Plate (not pictured) Part # Description A I7-LCP Lamp Cap B I7-6A C When ordering = style * = number of lamps # = size.
12 AGM Isolating Safety Switch with Cover (Optional Item C7-SWC) The AGM isolating safety switch allows the guidance sign power control & circuitry to be isolated from the airfield CCR circuit, providing a greater measure of safety when performing maintenance. This allows the rest of the airfield circuitry to remain illuminated to maintain necessary communication to pilots. The isolating safety switch is weatherproof with an IP67 rating and also includes a weatherproof cover that provides additional protection against mechanical damage. The switch is a DPDT (double pole double throw) style switch. Two terminals are for power to the PCM, two terminals are power from the isolation transformer, and two are the short circuit path. Catalog # C7-SWC Isolation Transformer short Catalog # C7-SWC Power Supply from Isolation Transformer Power to Sign PCM
INSTRUCTION MANUAL L WIND CONE
Cooper Industries DOCUMENT September 29, 2009 Revision B Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 Title: INSTRUCTION
More informationThis document describes:
Thank you for purchasing this product from ERM. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This programmable
More informationMega-Rail System Installation
Installation Manual Mega-Rail System P/N 030767-MRS 2003-2007 DODGE CUMMINS Mega-Rail System Installation Installation Instructions GDP 03-07 Mega-Rail System P/N 030767-MRS PLEASE READ ALL INSTRUCTIONS
More informationGDP STREET-GATE 38mm Wastegate System
Installation Manual STREET-GATE 38mm Wastegate System P/N SG67-38MM-7510 GDP STREET-GATE 38mm Wastegate System 07.5-10 DODGE CUMMINS Installation Instructions STREET-GATE 38mm Wastegate Kit p/n SG67-38MM-7510
More information30100 Module Installation Guide L
30100 Module Installation Guide 1997-2006 12.0L Mack Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 1997-2006 Mack 12.0L Engine Module +12 volts red wire. Ground black wire Injector
More informationMercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions
1999-2006 Mercedes MBE 906/926 6.4L & 7.2L Engine Module Part # 15000 Installation Instructions 15000_revC 1999-2006 Mercedes 6.4L & 7.2L Engine Module +12 volts red wire. Ground black wire Injector Terminals
More informationGM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com
21700 Module Installation Guide 2017 GM 6.6L Duramax *L5P* Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable Switch Female Fuel Pressure Sensor Connector Male Fuel Pressure Sensor Connector
More informationRaydot LLC 24 Actuator (115 VOLT)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. Raydot LLC 24 Actuator (115 VOLT) 145 Jackson Ave. S. Cokato, MN 55321-USA (320) 286-2103
More information15100 Module Installation Guide Mercedes EPA07 w/dpf
15100 Module Installation Guide 2007-2009 Mercedes EPA07 w/dpf 7.2L Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 2007-2009 Mercedes 7.2L Engine Module +12 volts red wire. Ground
More informationThis document describes:
Thank you for purchasing this product from ERM Products. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This universal
More informationManual Transfer Switch
Manual Transfer Switch Instruction Manual 30 1200 Amp 2, 3 & 4 Pole Page 1 WARNING Before Installation READ THIS MANUAL carefully to learn how to properly install, operate and maintain this unit. Personal
More informationII DISTRIBUTION & SUBSTATION TYPE C
CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e
More informationDODGE CUMMINS Air-Boss CR Intake Plenum
Installation Manual P/N 0307-ABIP 2003-07 DODGE CUMMINS Air-Boss CR Intake Plenum Installation Instructions P/N 0307-ABIP GDP Air-Boss CR Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationPOWER GEAR SLIDE-OUT MANUAL
POWER GEAR SLIDE-OUT MANUAL Operation Guide FLUSH FLOOR SLIDE-OUT SYSTEM FOR AMERICAN COACH PRODUCTS 82-S0220-01 Rev. 1 AMERICAN COACH SLIDE-OUT MANUAL FLUSH FLOOR SYSTEM TABLE OF CONTENTS SECTION PAGE
More information8" - 12" Hydraulic Steel Squeeze Off Tool
8" - 12" Hydraulic Steel Squeeze Off Tool ECN 19130 C812S Hydraulic Steel Squeeze Off Tool for Steel Pipe Page 1 of 8 This Footage Tools C812S Steel Squeeze Off Tool is sold with one pump configuration
More information24 Linear Actuator 115 Volts A.C. (Cat. # C430A)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. 24 Linear Actuator 115 Volts A.C. (Cat. # C430A) Page 1 of 8 IS10007.doc 11/15/06 IMPORTANT!
More informationRANGE HOODS USER INSTRUCTIONS
RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions
More informationMcCANNA Actuation Systems B
17710-B Ramcon Series 8/25 C/CR, 50/100 B/BR, 250/500 B/BR Electric Actuators Installation, Operation and Maintenance Instructions Contents Storage...........................................................................................................
More informationDodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -
29 September 2005 Dodge Cummins Low Fuel Pressure Alarm Light Kit 1081130-33 1 1999-2005 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130 Red 1081133
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More information20250 Module Installation Guide
20250 Module Installation Guide 2013.5-2017 RAM 6.7L Cummins Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable switch connector Power +12 volts (Red wire) & Ground (Black wire) Injector
More information48" and 52" Hyflo Fans Installation and Operators Instruction Manual
48" and 52" Hyflo Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should arise,
More informationAGRI-COVERTM SWITCH CONTROL INSTRUCTIONS
AGRI-COVERTM SWITCH CONTROL INSTRUCTIONS Use these instructions in place of the rocker switch and solenoid sections in your roll tarp or ROLTECTM Electric Hopper Conversion instructions. Some installs
More informationINSTALLATION INSTRUCTIONS AND PARTS LIST SUPPLEMENTAL WIND CONE FIXTURE FAA L-806 PART NUMBER LIGHTED PART NUMBER UNLIGHTED
Cooper Industries Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 DOCUMENT 8512 May 3, 2004 Revision B Title: INSTALLATION
More informationModel Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS
PumpAgents.com - Click here for Pricing/Ordering Model 36600-Series ELECTRIC BILGE PUMPS FEATURES Self-Priming Diaphragm Design Allows Dry Running Quiet Operation Built-in Hydraulic Pulsation Dampener
More informationCTFRP Series Power Supplies
CTFRP Series Power Supplies Ferroresonant Non-Standby Power Supplies User Manual Myers Power Products 6/2013 CTFRP Series Manual Chapter 1 General Information The Myers CTFRP Series Power Supply provides
More informationAD-7 THERMAL INDICATING AMMETER
AD-7 THERMAL INDICATING AMMETER a nd ACCESSORIES Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7.
More informationINSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09
HAND CRANK & MOTORIZED POWER CORD REELS: SERIES 1125PC SERIES: 1125PC HAND CRANK SERIES: 1125PC MOTORIZED COXREELS The technical data and images which appear in this manual are for informational purposes
More informationTRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10
TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10 TAPS INSTALLATION GUIDE V1.10 1 TRAILER AUXILIARY POWER SYSTEM CONTENTS General Information and System Logic... 2 Diagrams... 3 System Diagram
More informationAir-Boss VP Intake Plenum
Installation Manual P/N 98502-ABIP 98.5-02 DODGE CUMMINS Air-Boss VP Intake Plenum Installation Instructions P/N 98502-ABIP GDP Air-Boss VP Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationTitle: INSTRUCTION MANUAL HIGH INTENSITY RUNWAY LIGHT/QUARTZ (HRLQ) FAA L-862. DOCUMENT 8922 August 28, 2012 Revision S
Cooper Industries Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 DOCUMENT 8922 August 28, 2012 Title: INSTRUCTION MANUAL
More informationMotorized Stainless 2-Way Valves
Installation and Operation Manual Motorized Stainless 2-Way Valves Safety Valve ETV Applications WARNING This Heat-Timer valve is strictly an operating valve; it should never be used as a primary limit
More informationAirfield Signs Lighting. L-858 Taxiway & Runway. Product Solutions Catalog. Halogen and Fluorescent. Installation ManualInstallation Manual
Installation ManualInstallation Manual L-858 Taxiway & Runway Airfield Signs Lighting Product Solutions Catalog Halogen and Fluorescent 96A086, Rev. AN, www.adb-air.com L-858 Taxiway & Runway Signs 96A086
More informationCRD610 Automatic Fitting Inserter
CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3
More informationMV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe
More informationDODGE CUMMINS Arctic-Heat Grid Relocation Kit
Installation Manual P/N 07509-350-GRK 2007.5-09 DODGE CUMMINS Arctic-Heat Grid Relocation Kit Installation Instructions P/N 07509-350-GRK GDP Arctic-Heat Grid Heater Installation PLEASE READ ALL INSTRUCTIONS
More informationSPC-PANEL Simplex, Single Phase Pump Control Panel
Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner
More informationInstallation / Operation Instructions Sunnex ORION Series Exam Lights
Installation / Operation Instructions Sunnex ORION Series Exam Lights OR-120 OR-127 OR-220 OR-227 Models: OR-300 OR-400 OR-500 OR-600 1. APPLICATIONS The Sunnex ORION Series light was designed specifically
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More informationDODGE CUMMINS MK-2 Micro-Kleen System
Installation Manual P/N MK20306 2003-07 DODGE CUMMINS MK-2 Micro-Kleen System Installation Instructions P/N MK20306 2 Micron Fuel Filter Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
More informationInstruction Manual For Baldor Buffers
No. 280F Replaces 280E LB7011 Instruction Manual For Baldor Buffers SAFETY NOTICE: WARNING statements describe conditions that may lead to personnel injury including potentially fatal injuries if the machine
More informationRapid Flow Induction Dodge Cummins 5.9L 52101
INSTALLATION Manual Rapid Flow Induction Vehicle Application Part Number 03-07 Dodge Cummins 5.9L 52101 TROUBLESHOOTING: If you have questions during the installation of this product, please visit www.bullydog.com/product_updates.php.
More informationSmart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual
Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX Owner s Manual Table of Contents Important Safety Instructions 2 Features 3 Installation Guidelines 5 Warranty 8 1.0 Important
More informationJD2800 Module Installation Guide
Up to 30% More Horsepower 10-20% Fuel Savings John Deere 9.0L Tier III Denso Common Rail Engines JD2800 Module Installation Guide AgDieselSolutions.com Ground Terminal Power (+12V constant) Terminal Injector
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A E355088 READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual
More informationCummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200
1994-2003 Cummins N14 Celect & Celect Plus Engine Module For Agricultural Applications Only Part # 31200 31200_revA Adjustable Switch Agricultural Cummins N14 Engine Module Power and Ground terminals Timing
More informationDODGE CUMMINS GDP Twin CP-3 Big Line Kit
Installation Manual P/N 0306-TCP3 2003-07 DODGE CUMMINS GDP Twin CP-3 Big Line Kit Installation Instructions P/N 0306-TCP3 GDP Twin CP-3 Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationCU6703 Module Installation Guide
Up to 30% More Horsepower 10-20% Fuel Savings Cummins 6.7L Tier III Engines CU6703 Module Installation Guide AgDieselSolutions.com MAP sensor male and female connectors. Power and Ground wires. Module
More informationDO NOT DISCARD Important information for AIRPORT MAINTENANCE DEPT
IRFIELD SIGNS R Installation Instructions for Taxiway & Runway Signs Size, Size, Size 3 & Size 5 DO NOT DISCRD Important information for IRPORT MINTENNCE DEPT To install:. Locate the frangible couplings
More informationINSTALLATION. Note: Not all of the included parts will be used during this installation. -cont.-
Driving Lights for Road Glide 5007 Fits: 98-up Road Glide PartS Included 1 Right Light Assembly 1 Left Light Assembly 1 Right Mounting Bracket 1 Left Mounting Bracket 1 Hardware Kit Including: 2 Narrow
More information"WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD200SS TUBE EXPANDER OPERATIONS MANUAL VERSION 4.3 LAST EDITED 06.17.15 cleanroomdevices.com Table of Contents Table of Contents....1
More informationAutomated I.V. Stand Cat. No OPERATOR S MANUAL. Operation& Maintenance Instructions. Raising the Standard of Care!
Automated I.V. Stand Cat. No. 741314 OPERATOR S MANUAL Operation& Maintenance Instructions Raising the Standard of Care! Table of Contents Warranty....................... 2 Hardware.......................
More informationAdjustable Angled Incline Conveyor Owners Manual with Operating Instructions
Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Revision 012211 Table of Contents Basic Conveyor Features 3 Getting Started 4 Setting Up the Incline Conveyor 5 Belt Removal
More informationThank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.
OWNER S MANUAL Safety First Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment. Questions or Concerns? 911EP wants to quickly resolve
More informationPatient Care Facility
ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for
More informationDODGE CUMMINS GDP Big Line Kit
Installation Manual P/N 9852BLK 1998.5-2002 DODGE CUMMINS GDP Big Line Kit Installation Instructions P/N 9852BLK GDP Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
More information4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:
4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: 05-15-07 PART#: 98-0006-06 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of
More informationDeluxe ASA Halogen Spot/Flood Light
Installation & Operation Instructions Deluxe ASA Halogen Spot/Flood Light 405610-3 To avoid the risk of accidents or damage to this product, it is essential to read these instructions thoroughly before
More informationBlue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases
Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96
More informationModel C230 Pump Controller
MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is
More informationReach ins, Freeezers & Refrigerators Installation & Operation Manual
Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com
More informationDrug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions
ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control
More informationTK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/17/14
Tech Line: (952) 985-5675 Fax (952) 985-5679 21730 Hanover Ave. Lakeville, MN 55044 www.qa1.net www.facebook.com/qa1motorsports TK08 TUNING KIT TECHNICAL MANUAL CONTENTS UNDER PRESSURE! USE EXTREME CAUTION
More informationLED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)
LED TROUBLESHOOTING Controller Version L610 Rev 7M or newer (manufactured after 1/21/15) Last update 11/5/18 The purpose of this document is to help the airfield electrician troubleshoot the Lumacurve
More informationIllumifalls Patio Pond
Illumifalls Patio Pond REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-755-4497,
More informationSlimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current
Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current Thank you for buying a Rinehart Racing exhaust system. We are committed to providing premium products that with proper
More informationOperating Instructions for PAC800 Battery Charger
Operating Instructions for PAC800 Battery Charger General Safety The charger may only be used for the specified battery types. This battery charger is supplied with pre-set charging curves that are adapted
More information4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:
4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: 12-04-07 PART#: 98-0001-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE
More informationRACE PPE Manifolds and Up-Pipes
RACE ONLY High-Flow Exhaust Manifolds with Up-pipes GM DURAMAX 6.6L 2001-2015 DISCLAIMER OF LIABILITY This is a performance product which increases horsepower above factory specifications. Additional horsepower
More informationTK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/25/14 Tech Line: (952) Fax (952)
Tech Line: (952) 985-5675 Fax (952) 985-5679 21730 Hanover Ave. Lakeville, MN 55044 www.qa1.net www.facebook.com/qa1motorsports TK08 TUNING KIT TECHNICAL MANUAL CONTENTS UNDER PRESSURE! USE EXTREME CAUTION
More informationINSTALLATION INSTRUCTION & OWNER S MANUAL
CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful
More informationPump Installation and Service Manual HRS Hydromatic Retractable System
Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party
More informationINSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09
HAND CRANK WELDING CABLE REEL: SERIES 100WC COXREELS The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES
More information36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions
6" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual Fan and Framing Dimensions Planning the layout of the spacing between Fans is very important. Spacing too close together
More information400 Watt WIND TURBINE
400 Watt WIND TURBINE User s Manual Congratulations on your Coleman solar product purchase. This product is designed to the highest technical specifications and standards. It will supply years of maintenance
More informationDutchman I N D U S T R I E S
Dutchman I N D U S T R I E S DIVISION OF Dutchmaster Nurseries Ltd. Stabilizers O w n e r s M a n u a l Manufactured and Sold by Dutchman Industries Inc. 3735 Sideline 16, Brougham, Ontario, Canada L0H
More informationMaxLite LED Linear HighBay Fixtures
Operating Instructions MaxLite LED Linear HighBay Fixtures General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions,
More informationEZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty
EZ-R7 T-Plug Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors Installation Instructions and Product Warranty Professional Installation Required Thank you for purchasing
More informationSUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200
More informationHarley Davidson FL Touring Current Xtreme
ITEMS SUPPLIED Description Part # Qty Front Header (Chr/Blk) 100-0119/100-0123 1 Rear Header (Chr/Blk) 100-0120/100-0124 1 Front Heat Shield (Chr/Blk) 100-0121/100-0125 1 Rear Heat Shield (Chr/Blk) 100-0122/100-0126
More informationL DODGE CUMMINS Maximizer System
Installation Manual P/N 07509MAX 2007.5-09 6.7L DODGE CUMMINS Maximizer System Installation Instructions P/N 07509MAX GDP Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
More informationInstallation Manual. L-858 Taxiway & Runway Signs. AGSF, Halogen Signs. 96A0286, Rev. AR, 7/20/17 AM e Edition 1.0
AGSF, Halogen Signs This manual is only for use with the Halogen "SH" and "SW" series L-858 signs. For Fluorescent information on "SF" and "SN" signs, see the AP revision of this manual in the obsolete
More informationMicroscope light manual
Microscope light manual LS-12 and LS-14 LS-12 LS-14 1/9 Content Overview... 3 Mounting... 4 Light adjustment... 5 Mirror... 6 Filters... 6 Replacing microscope light... 7 Technical data... 8 Troubleshooting...
More informationL DODGE CUMMINS MK-2 + BLK APPS Mount
Installation Manual P/N MK20305-APPS 2003-05 5.9L DODGE CUMMINS MK-2 + BLK APPS Mount Installation Instructions P/N MK20305-APPS 2 Micron + Big Line Kit APPS Mount Installation PLEASE READ ALL INSTRUCTIONS
More informationLIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light
LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light Installation & Operation Manual This manual covers the following models: LightStick #19300 LightStick Plus #19301 GENERAL This product emits germicidal
More informationInstallation & Operation Manual Chef Base
Installation & Operation Manual Chef Base Please read this manual completely before installing or operating this unit! BACB53 BACB53M BACB71 BACB71M BACB74 BACB74M BACB83 BACB83M BACB86 BACB86M BACB96
More informationCompressor Clutch Replacement Procedure
Clutch Replacement Procedure P-1401-WE 819-0316 Installation Instructions An Altra Industrial Motion Company Warner Replacement Clutches for the following compressors: Denso 6E171 10P15 6P148 6C17 Ford
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More informationHYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS
HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS SPECIFICATIONS 1 PRINCIPLE OF OPERATION 1 INSTALLATION 2 Choosing a Sampling Location 2 Mounting the Enclosure 2 Remote Alarm
More informationCRD600 Automatic Fitting Inserter
CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3
More informationTechnical Support Line: (952) Fax Line: (952) Hanover Ave. Lakeville, MN
Technical Support Line: (952) 985-5675 Fax Line: (952) 985-5679 21730 Hanover Ave. Lakeville, MN 55044 www.qa1.net INSTALLATION INSTRUCTIONS QA1 P/N CC104MU Camber Caster Plates 1994-2004 Mustang 5.0/4.6
More informationINDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:
INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: 02-02-09 PART#: 98-0006-05 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE
More informationTBM Series 3-Way Ball Valve
www.simtechusa.com TBM Series 3-Way Ball Valve Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 06-26-13 TBM Series Ball Valves SIMTECHRECOMMENDSREADINGTHEFOLLOWINGINFORMATIONPRIORTOINSTALLINGANDUSING
More informationLevel One Electric Vehicle Charging Station Wall Mount Product Guide
Level One Electric Vehicle Charging Station Wall Mount Product Guide Model # WU-120 ShorePower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com 2 Table
More informationINSTALLATION MANUAL DURAMAX DIESEL POWERED PICKUP TRUCKS MODEL RP-100 & RP-150. With New Quick Connect Components!
INSTALLATION MANUAL 2001-2009 DURAMAX DIESEL POWERED PICKUP TRUCKS MODEL RP-100 & RP-150 With New Quick Connect Components! PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION! 705
More informationIllumifalls Kit REMINDER CALL BEFORE RETURNING TO STORE.
Illumifalls Kit REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. MODEL/MODELO #AISB12K Questions, problems, missing parts? Before returning to your retailer, call our customer service department
More informationCOMPRESSED AIR LOADER MODEL: AL-1
COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection
More informationMV Series Motors Operation & Parts Manual
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson
More informationDO NOT DISCARD Important information for AIRPORT MAINTENANCE DEPT
Installation Instructions for Taxiway & unway Signs Size, Size, Size & Size 5 DO NOT DISCAD Important information for AIPOT MAINTENANCE DEPT To install:. Locate the frangible couplings (item # see Electrical
More information