Food Service Technology Center
|
|
- Hubert Ralf Davis
- 6 years ago
- Views:
Transcription
1 Food Service Technology Center Baxter OV500G1-EE Gas Single Rack Oven Test Report Application of ASTM Standard Test Method F March 2014 Prepared by: Michael Karsz Fisher-Nickel, Inc. Prepared for: Pacific Gas and Electric Company Customer Energy Efficiency Programs PO Box San Francisco, California Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2014
2 Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility. The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor. Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, Inc. and the FSTC do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. Disclaimer Copyright 2015 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Fisher- Nickel, Inc., PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights. Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Fisher-Nickel, Inc., the FSTC, or PG&E. In no event will Fisher-Nickel, Inc. or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report. Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report. Revision History Revision num. Date Description Author(s) 0 Mar 2014 Initial Release M. Karsz 1 Nov 2015 Added ENERGY STAR Qualification Page M. Karsz Page 2 of 15 CP
3 Contents Page Equipment Description. 4 Test Location 4 Ventilation. 4 Test Instrumentation Inventory.. 5 FSTC Test Report: Results.. 6 Additions, Deviations, and Exclusions 10 ENERGY STAR Qualification.. 11 Manufacturer Specifications Sheet Report Certification.. 14 Page 3 of 15 ECP
4 Equipment Description Test Work Order Number (TWO) Manufacturer Baxter Model OV500G1-EE Serial Number Generic Equipment Type Single Rack Oven Gas Rated Input 175,000 Btu/h Construction Stainless Steel Controls Programmable Digital Control External Dimensions (W x D x H) 55.0" x 51.0" x 99.5" Custom Settings (if any) Energy Saving 250 F Test Location All testing was performed under controlled conditions in the FSTC laboratory facilities at Alcosta Blvd., Suite 101, San Ramon, CA Ventilation FSTC researchers installed the equipment on a tiled floor under a four-foot-deep canopy hood, which operated at a nominal exhaust rate of 300 cfm per linear foot. The hood was mounted six feet, six inches above the floor, with at least six inches of clearance between the vertical plane of the equipment and the hood s edge. Page 4 of 15 CP
5 Test Instrumentation Inventory Description (ID) Manufacturer Model Measurement Range Resolution Calibration Date Next Calibration Gas Meter (ALE506) Sensus CFH 0.05 ft³ 11/27/ /12/2015 Electric Meter (ALA101) Electro Industries Shark A 7.5 Wh 12/13/ /12/2014 Electric Meter (ALD412) Continental Control WNB-3Y-208P 0 20 A 0.02 Wh 12/12/ /12/2014 DAQ Temp (ALC312) National Instruments FP-TC F 0.1 F 08/07/ /07/2014 DAQ Pulse (ALC312) National Instruments FP-CTR-500 < 50 khz 50 khz 08/07/ /07/2014 Thermometer (ALE502) Fluke F 0.1 F 12/10/ /12/2014 Pit Scale (FSTCS001) Metler ID lb 0.01 lb Verified Internally w/ ALE503 Scale (ALB203) Metler SB lb lb 11/12/ /12/2014 Flow Meter (OWM109) Omega FTB gpm gal (Verified (Verified internally on internally as 02/10/2014) needed) Page 5 of 15 CP
6 FSTC Test Report: Results Purpose of Testing This testing determined the energy input rate, preheat time and energy, idle energy rate, heavy-load cooking-energy efficiency in convection and steam modes by applying ASTM F Energy Input Rate Rated Voltage (V) 208 Rated Energy Input Rate (Btu/h) 175,000 Measured Energy Input Rate (Btu/h) 174,719 Difference (%) 0.2 Electric Energy Rate (kw) 0.86 Baxter OV500G1-EE Single Rack Oven: Preheat Ambient Temperature ( F) 74.7 Final Preheat Temperature ( F) 390 Duration (min) Gas Energy Consumption (Btu) 42,274 Electric Energy Consumption (kwh) 0.21 Preheat Rate ( F/min) 18.9 Nameplate Information: Idle Ambient Temperature ( F) 74.0 Average Cavity Temperature ( F) 401 Gas Idle Energy Rate (Btu/h) 21,364 Electric Energy Rate (kw) 0.54 Heavy-Load Baking-Energy Efficiency a Ambient Temperature ( F) 72.6 Food Product Apple Pie Oven Temperature ( F) 400 Cook Time (min) Gas Baking Energy Rate (Btu/h) 65,241 Energy to Food (Btu/lb) 212 Energy to Oven (Btu/lb) 477 Electric Baking Energy Rate (kw) 0.70 Baking-Energy Efficiency (%) 48 ± 0.7 Production Capacity (lb/h) 142 ± 2.6 a based on a minimum of three test replicates. Baxter State Route 162 East Orting, WA, USA Page 6 of 15 R-RO
7 Set Back Energy-Saving Mode Average Cavity Temperature ( F) 234 Gas Idle Energy Rate (Btu/h) 6,486 Electric Energy Rate (kw) 0.05 Steam Performance (10s Water Injection Time) Cycle Water Consumption (gal) Runoff (gal) Steam Produced (gal) Heavy-Load Baking Test Data Measured Values Test #1 Test #2 Test #3 Test Date 2/12/14 2/13/14 2/13/14 Number of Pans Initial Weight of Apple Pies (lb) Final Weight of Apple Pies (lb) Weight of Sheet Pans (lb) Initial Temperature of Apple Pies ( F) Final Temperature of Apple Pies ( F) Initial Moisture Content of Apple Pies (%) Cook Time (min) Test Voltage (V) Electric Energy Consumption (Wh) Gas Energy Consumption (Btu) 60,168 60,180 60,384 Gas Heating Value (btu/scf) 1,025 1,020 1,020 Calculated Values Specific Heat of Apple Pies (Btu/lb, F) Sensible Energy (Btu) 15, ,404 Latent Fusion Energy (Btu) 9,317 9,312 9,331 Latent Vaporization Energy (Btu) 3,259 3,075 3,269 Total Energy to Food (Btu) 27,677 27,643 28,004 Energy to Food (Btu/lb) Energy Consumed by Pans (Btu) 1,984 2,011 2,025 Energy Consumed by the Rack Oven (Btu) 62,352 62,398 62,568 Energy to Oven (Btu/lb of food cooked) Results Baking-Energy Efficiency (%) Gas Baking Energy Rate (Btu/h) 65,105 64,768 65,850 Electric Baking Energy Rate (kw) Production Capacity (lb/h) Page 7 of 15 R-RO
8 Sheet Cake Browning Uniformity Food Product White Cake Mix Bake Time (min) Top Pan Middle Pan Bottom Pan Page 8 of 15 R-RO
9 Energy Cost Model The test results can be used to estimate the annual energy consumption for the single rack oven in a real-world operation. A simple cost model was developed to calculate the relationship between the various cost components (e.g., preheat, idle and baking costs) and the annual operating cost using the ASTM test data. The cost model incorporates the set back mode during idle periods, which is the normal operating state for this single rack oven. Daily Oven Operation Assumptions Total Operating Time per Day (h) 12 Operating Time in Set Back Mode per Day (h) 3 Operating Days per Year (d) 365 Number of Preheats per Day 1 Total Amount of Food Baked per Day (lb) 600 Based on the assumptions above, total daily energy consumption was determined by adding the daily preheat energy consumed, the daily idle and set back energy consumed, and the daily baking energy consumed. It is estimated that the Baxter OV500G1- EE Single Rack Oven would consume 1,583 therms of gas and 2,099 kwh of electricity annually. Using a rate of $1.00/therm and $0.10/kWh, the estimated operational cost of Baxter OV500G1-EE Single Rack Oven is $1,793 per year. Estimated Single Rack Oven Energy Consumption and Cost Gas (Btu) Electric (kwh) Daily Preheat Energy 42, Daily Idle Energy 96, Daily Set Back Energy 19, Daily Baking Energy 275, Annual Gas Consumption (therms/yr) a 1,583 Annual Electric Consumption (kwh/yr) 2,099 Total Annual Cost ($/year) b $1,793 a One therm = 100,000 Btu b Oven energy costs are based on $1.00/therm and $0.10/kWh (national average; prices may vary greatly depending on region). Page 9 of 15 R-RO
10 Additions, Deviations, & Exclusions Additions: The following procedure was employed to evaluate the set back/energy-saving mode of the Baxter OV500G1-EE: - Enable the rack oven s set back mode. If applicable, set temperature and time settings as per manufacturer s instructions. - Preheat the rack oven to 400 F and allow to stabilize for the allotted set back time. - Once set back is engaged, allow the rack oven sufficient time to cool to the set point set back temperature. - Allow the rack oven to stabilize at the set back temperature for 2 h. - Monitor baking cavity temperature and rack oven energy consumption for an additional 3 h while the rack oven is operating in this condition. - Report the rack oven s gas energy rate, electric energy rate, and average cavity temperature for the 3 h in set back mode. Deviations: As per manufacturer s request, the Baxter OV500G1-EE was tested at 175,000 Btu/h rather than the 180,000 Btu/h listed on the nameplate. Exclusions: None. Page 10 of 15 CP
11 ENERGY STAR Qualification FSTC testing of the Baxter OV500G1-EE Gas Single Rack Oven resulted in an idle rate of 21,364 Btu/h and an energy efficiency of 48%. The results comply with the ENERGY STAR program requirement for Commercial Ovens, version 2.2 Page 11 of 15 ECP
12 Manufacturer Specifications Sheet Page 12 of 15 CP
13 Manufacturer Specifications Sheet (Continued) Page 13 of 15 CP
14 Page 14 of 15
15 Page 15 of 15
Food Service Technology Center
Food Service Technology Center Convotherm C4eT 6.20EB Electric Combination Oven Test Report Application of ASTM Standard Test Method F2861-10 May 2015 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Piper NAEB102 Electric Combination Oven Test Report Application of ASTM Standard Test Method F2861-10 November 2015 Prepared by: Michael Slater Fisher-Nickel, Inc. Prepared
More informationFood Service Technology Center
Food Service Technology Center Sapidus H2Oil UE-1100 (240V) Electric Fryer Test Report Application of ASTM Standard Test Method F1367-07 November 2015 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Frymaster BIELA214-2RCSD Electric Fryer Test Report Application of ASTM Standard Test Method F1361-07 September 2016 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Giles GGF-400 Gas Fry Kettle FSTC Report # 501311131-R0 Application of ASTM Standard Test Methods F1964-11, 1361-07 December 2012 Prepared by: Adam Cornelius Denis Livchak
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationSpring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report
Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F1704-09 FSTC Report 501311275 Food Service Technology Center Prepared
More informationVulcan, VPX5 Electric Steamer Performance Test
Vulcan, VPX5 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.02 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel
More informationWatlow Model Firebar 1000 and 1600 Prototype Element Performance Test
Watlow Model Firebar 1000 and 1600 Prototype Element Performance Test In a standard fryer In accordance with ASTM Standard Test Method F 1361-95 FSTC Report 5011.98.60 Food Service Technology Center Manager:
More informationMarket Forge, ET-5E Electric Steamer Performance Test
Market Forge, ET-5E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.98 Food Service Technology Center Final Report, April 2001 Prepared by: Todd
More informationVulcan, VPX3 Electric Steamer Performance Test
Vulcan, VPX3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.01 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel
More informationMarket Forge, ET-3E Electric Steamer Performance Test
Market Forge, ET-3E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.99 Food Service Technology Center Final Report, April 2001 Prepared by: Todd
More informationThermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test
Thermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test Application of ASTM Standard Test Method F 1695-03 FSTC Report 501310104 March 2011 Prepared by: Greg
More informationCleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test
Cleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.84 Food Service Technology Center Final Report, November
More informationVulcan-Hart Gas Steamer Performance Testing Model VHX24G-3
Vulcan-Hart Gas Steamer Performance Testing Model VHX24G-3 Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.97 Food Service Technology Center Final Report, February 2001 Prepared
More informationCommercial Food Service Equipment Specifications for California Investor-Owned Utility-Based Incentives 2015
Commercial Foodservice Appliance Qualification Requirements for the California Energy Wise Program: Any Commercial cooking appliances must have a representative model tested and verified by a California
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationGaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report
Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Method F1704-09 FSTC Report 5011.09.06-R1 Food Service Technology Center Prepared by:
More informationGaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report
Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F 1704-05 Food Service Technology Center (www.fishnick.com) -R1 Prepared
More information2013 Spring Calendar. be energy wise. California Utilities Partnering for Energy Efficiency. California Energy Wise Foodservice Seminars
California Utilities Partnering for Energy Efficiency 2013 Spring Calendar California Energy Wise Foodservice Seminars Energy-Efficient Equipment Demonstrations be energy wise Informative Educational Seminars
More informationVulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric)
Vulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric) Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.85 Food Service Technology Center
More informationCOMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION
COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION 1. CUSTOMER INFORMATION (please print) Account Name Doing Business As (if different from Account Name) Installation Address City State Zip Code Mailing
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationAccuTemp STEAM n HOLD, Model 208-D8-300 Electric Steamer Performance Test
AccuTemp STEAM n HOLD, Model 208-D8-300 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.99.75 Food Service Technology Center Manager: Don Fisher Final
More informationAccuTemp, Model S3 Electric Steamer Performance Test
AccuTemp, Model S3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-05 FSTC Report # 5011.05.08 April 2005 Prepared by: Chuck Wallace Victor Kong David Zabrowski Fisher-Nickel,
More informationVulcan ER50D Electric Fryer Performance Tests
Vulcan ER50D Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-07 FSTC Report 5011.08.04 December 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,
More informationAccuTemp STEAM N HOLD, Model 208-D Electric Steamer Performance Test
AccuTemp STEAM N HOLD, Model 208-D12-300 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report # 5011.03.02 (Revised) June 2003 Prepared by: Todd Bell David Zabrowski
More informationPerformance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment
AHRI Standard 1060 (I-P) 2011 Standard for Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does
More informationProject Title: Contract Number: Milestone Number: Report Date: Contract Contact: Phone: Congressional District: Executive Summary:
Project Title: 350 kw Target Midway Solar PV Project Contract Number: EP4-20 Milestone Number: 1 Report Date: 12/28/2016 Contract Contact: Brittany Stanton Phone: 612-696-0823 Congressional District: MN
More informationFrymaster Protector Gas Fryer Performance Tests
Frymaster Protector Gas Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.03 February 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FOOD SERVICE TECHNOLOGY CENTER 12949 Alcosta Blvd Suite 101 San Ramon, CA 94583 Richard Swierczyna Phone: 925-866-2844 Email: rswierczyna@fishnick.com MECHANICAL
More informationBorrego Springs Microgrid Demonstration Overview
Borrego Springs Microgrid Demonstration Overview Society of American Military Engineers San Diego, CA March 11, 2015 Neal Bartek Distributed Energy Resources Manager 2012 San Diego Gas & Electric Company.
More informationGlendale Water & Power Smart Grid Project
Glendale Water & Power Smart Grid Project Key Dates in Project History Key Dates Project History On July 10, 2007, City Council directed GWP to develop a long term plan for smart meters On October 23,
More informationEquipment Capital Budget Justification
Equipment Capital Budget Justification Hilary Shone Purpose: We are looking to expand our foodservice production capacity and need an additional, energy-efficient oven to allow this increase in production.
More informationSANDAG Vanpool Program Guidelines as of February 2018
SANDAG Vanpool Program Guidelines as of February 2018 The San Diego Association of Governments (SANDAG) administers the SANDAG Vanpool Program to provide alternative transportation choices to commuters,
More informationFrymaster 22 kw Protector Electric Fryer Performance Tests
Frymaster 22 kw Protector Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.11 May 2008 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc.
More informationPower Distribution Units
Power Distribution Units AP9562, AP9563, and AP9564 AP9562, AP9563, and AP9564 are 15- and 20-amp Rack Power Distribution Units (PDUs) that provide 120-volt power to rack-mounted equipment. AP9562, -.,
More informationWARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN
WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationSacramento Municipal Utility District s EV Innovators Pilot
Sacramento Municipal Utility District s EV Innovators Pilot Lupe Jimenez November 20, 2013 Powering forward. Together. Agenda SMUD Snapshot Pilot Plan v Background v At-a-Glance v Pilot Schedule Treatment
More informationLSI SAS e HBA Temperature and Airflow
LSI SAS 9206-16e HBA Temperature and Airflow Application Note Preliminary, Version 1.0 DB06-000784-00 Revision History Version and Date Preliminary, Version 1.0, Initial release of this document. Description
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationModel SSKR Automate Vehicle Anti-Theft System
Model SSKR Automate Vehicle Anti-Theft System Owner s Guide limited lifetime consumer warranty Directed Electronics, Inc. promises to the original purchaser to repair or replace with a comparable reconditioned
More informationCity Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.
To be completed by Solar Electric Design Ally and Project Owner Don't Forget to Include Project Owner and Design Ally Signatures Site Layout Sun Chart Wiring Schematic Program Use Only FastTrack ID Project
More informationToro Sprayer Calibration Tool
Commercial Products Toro Sprayer Calibration Tool User Guide & Installation Instructions Toro Sprayer Calibration Tool 1 Table of Contents Introduction... 2 Program Instructions... 4 Toro Software End
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL
ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 4.8 April, 2013 TABLE OF CONTENTS Section Page 1. INTRODUCTION...1 1.1 Description...1 1.2 Uncrating...1 1.3 Serial
More informationPage Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6
TC-SGRAH1-1005 October 05 R Series - High Efficiency Multi-position Air Handler Engineering and Specification Guide (Electric and No Heat) With optional field conversion downflow kit Contents: Page Number
More informationXXXXX. Kokish River Hydroelectric Project. Interconnection Facilities Study and Project Plan
XXXXX Kokish River Hydroelectric Project Interconnection Facilities Study and Project Plan March 16, 2011 British Columbia Hydro and Power Authority British Columbia Hydro and Power Authority 2010. All
More informationREDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL
More informationFood Service Equipment Application
Food Service Equipment Application July 1, 2013 - June 30, 2014 Customer Information Company Anticipated Installation Date (Approval required prior to installation) Electric Utility Serving Applicant Electric
More informationModel D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION
"Success through Unity" Model D Spray Gun Parts Identification Manual 2943J-ID June 17, 2003 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood, New Jersey,
More informationBuilding Blocks and Opportunities for Power Electronics Integration
Building Blocks and Opportunities for Power Electronics Integration Ralph S. Taylor APEC 2011 March 8, 2011 What's Driving Automotive Power Electronics? Across the globe, vehicle manufacturers are committing
More informationThe Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives
The Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives Steve Lindenberg U.S. Department of Energy Jim Green National Renewable Energy Laboratory WINDPOWER 2006 Pittsburgh, June 4-8,
More informationMulti-Stage Selective Catalytic Reduction of NO in Lean-Burn Engine Exhaust. B. M. Penetrante M. C. Hsiao B. T. Merritt G. E.
UCRL-JC-128071 PREPRINT Multi-Stage Selective Catalytic Reduction of in Lean-Burn Engine Exhaust x B. M. Penetrante M. C. Hsiao B. T. Merritt G. E. Vogtlin This paper was prepared for submittal to the
More informationUtilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken
Utilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken Bakken Artificial Lift and Production Denver, Colorado September 24 25, 2013 Chad Wocken*, John Harju, Grant Dunham, and
More informationCity of Palo Alto (ID # 6416) City Council Staff Report
City of Palo Alto (ID # 6416) City Council Staff Report Report Type: Informational Report Meeting Date: 1/25/2016 Summary Title: Update on Second Transmission Line Title: Update on Progress Towards Building
More informationRULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions
More information4lliedSig nal. Development of a Digital Control Unit to Displace Diesel Fuel With Natural Gas. Federal Manufacturing & Tech nolog ies. A. D.
Development of a Digital Control Unit to Displace Diesel Fuel With Natural Gas Federal Manufacturing & Tech nolog ies A. D. Talbott KCP-613-5913 I Published March 1997 Final ReporVProject Accomplishments
More information37SCENE 46SCENE 79SCENE
Installation and Operation Instructions LED SCENE LIGHT LED SCENE LIGHT 37SCENE 46SCENE 79SCENE 37SCENE 46SCENE Introduction The 37SCENE, 46SCENE, 79SCENE LED Scene Lights are designed for the emergency
More informationPanel Mount Digital Tachometer Model
User Guide Panel Mount Digital Tachometer Model 461950 Introduction Congratulations on your purchase of the Extech 461950 Panel Tachometer. This meter displays continuous readings from 5 to 99,990 rpm.
More information3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide
3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide Installing Tall Skirt on SVC and SVE cabinets Instructions July 2016 78-0015-3067-0 2 July 2016 78-0015-3067-0 Contents 1. General
More informationProject Title: Lowertown Ballpark (CHS Field) Solar Arrays Contract Number: EP4-34 Milestone Number: 1 Report Date: June 21, 2016
DEPARTMENT OF PARKS AND RECREATION DESIGN AND CONSTRUCTION CITY OF SAINT PAUL Mayor Christopher B. Coleman 400 City Hall Annex 25 West 4 th Street Saint Paul, Minnesota 55102 www.stpaul.gov/parks Telephone:
More informationSCC Greenhouse Gas Assessment
SCC Greenhouse Gas Assessment April 2015 March 2016 Produced by CO2balance UK Ltd March 2017 CO2balance UK Ltd, 1 Discovery House, Cook Way, Bindon Road, Taunton, Somerset, TA2 6BJ, UK Tel: +44 (0) 1823
More informationAmerican National Standard for Lighting Equipment Voltage Surge Requirements
American National Standard for Lighting Equipment Voltage Surge Requirements Secretariat: National Electrical Manufacturers Association Approved: December 21, 2017 American National Standards Institute,
More informationDigital Remote Wheels DRW-1
Digital Remote Wheels DRW-1 USER MANUAL Date 01.12.2018 2 Imprint Imprint Copyright 2018 Arnold & Richter Cine Technik GmbH & Co. Betriebs KG. All rights reserved. No parts of this document may be reproduced
More informationUser's Manual. Model Hot Wire Thermo-Anemometer. Introduction
User's Manual Model 407123 Hot Wire Thermo-Anemometer Introduction Congratulations on your purchase of Extech s Hot Wire Anemometer. This meter is equipped with a telescoping antenna, indicates air-flow
More informationA Member of the. Integrated Metering Technologies
I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe
More informationTANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)
Revision 0 TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U) R. F. Fogle September 15, 2002 Westinghouse Savannah River Company LLC Savannah River Site Aiken, South Carolina 29802 This document was prepared
More informationUser's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable
User's Guide Vane Anemometer Model 451112 Measures Air Velocity & Temperature Degrees C/F switchable 6 selectable units of measure Data Hold function Introduction Congratulations on your purchase of Extech
More informationCBC-160-1N and CBC-160-2N Clutch/Brake Controls
P-239-36 819-04 CBC-160-1N and Clutch/Brake Controls Installation Instructions An Altra Industrial Motion Company Contents Introduction...2 Specifications........................... 2 Installation...3
More informationTest Rig Design for Large Supercritical CO 2 Turbine Seals
Test Rig Design for Large Supercritical CO 2 Turbine Seals Presented by: Aaron Rimpel Southwest Research Institute San Antonio, TX The 6th International Supercritical CO 2 Power Cycles Symposium March
More information3M Three-Wall and Four-Wall Headers. Series 3XXX
1 of 7 M Three-Wall and Four-Wall Headers Series XXX Product 78-10-0008-0 Released: 0-0-11 of 7 Table of Contents Section Page 1. Scope........ M Customer Documents....... Performance and Test Descriptions...
More informationCharlotte Energy Hub. Restricted Siemens Energy Inc.
Charlotte Energy Hub Restricted Siemens Energy Inc. siemens.com World-Class Power Generation Equipment Facility 1.2 million square feet > $400 million invested since 2011 Full manufacturing and service
More information3M CP2 Press-Fit Headers and Sockets, 2 mm
1 of 7 3M CP2 Press-Fit Headers and Sockets, 2 mm A-Style CP2 Connectors CP2-SA110-G1-KR Right Angle Socket Connectors mated to CP2-HA110-GA1-KR Header Connectors 78-5102-0083-1 Revised Date: February
More informationInstallation Power Management Unit Battery Cables and Battery Harness
Installation Power Management Unit Battery Cables and Battery Harness Important Safety Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation
More informationUtilities (electric & natural gas) allocate resources to promote energy efficiency
Utilities (electric & natural gas) allocate resources to promote energy efficiency DCEO administers Public Sector through its Illinois Energy Now Program www.illinoisenergy.org Encourage investment in
More informationInstallation Instructions for: Channel Thermocouple Amplifier
Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you
More informationRECHARGE STATION OPERATION MANUAL. Version
RECHARGE STATION OPERATION MANUAL Version 1.0-0712 2014 by VirTra Inc. All Rights Reserved. VirTra, the VirTra logo are either registered trademarks or trademarks of VirTra in the United States and/or
More informationWeb Volume Control Model WV220
WEB CONTROL PRODUCTS User Manual Web Volume Control Model WV220 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationA Study of Lead-Acid Battery Efficiency Near Top-of-Charge and the Impact on PV System Design
A Study of Lead-Acid Battery Efficiency Near Top-of-Charge and the Impact on PV System Design John W. Stevens and Garth P. Corey Sandia National Laboratories, Photovoltaic System Applications Department
More informationGAS RULE NO. 12 Sheet 1 RATES AND OPTIONAL RATES A. APPLICABILITY
Revised Cal. P.U.C. Sheet No. 18229-G Cancelling Revised Cal. P.U.C. Sheet No. 14774-G GAS RULE NO. 12 Sheet 1 A. APPLICABILITY This Rule applies to rates and optional rates where PG&E provides any one
More informationTHE ALTERNATIVE FUEL PRICE REPORT
THE ALTERNATIVE FUEL PRICE REPORT Alternative Fuel Prices Across the Nation August 8, 2002 T his is the seventh issue of the Clean Cities Alternative Fuel Price Report, a quarterly newsletter keeping you
More information3 Automotive Structural Adhesives
Automotive Structural Adhesives TM Scotch-Grip Fastener Adhesives 2, 4844 (Normal Temp Formula) Data Sheet June 2 General Description M Scotch-Grip TM Fastener Adhesives are microencapsulated, room temperature
More informationTERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)
TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for
More information3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006; Amended December 15, 2011) 1.0 Purpose The purpose
More informationDr. Chris Dudfield. Chief Technology Officer Intelligent Energy. Sponsors
Dr. Chris Dudfield Chief Technology Officer Intelligent Energy Sponsors 7 th September 2017 Creating the blueprint for advanced fuel cell manufacturing Dr Chris Dudfield Chief Technology Officer 2 The
More informationBC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)
BCAHSG-2 3-Jun BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) 5 YEAR WARRANTY see warranty form for details Contents: Page Number Product Features 2
More informationNISSAN 370Z INTELLI-KEY Rev.:
Remote Starter NISSAN 70Z 009-00 INTELLI-KEY Rev.: 0096 009 Not included: x Fuse 5Amp x s Amp x Relays Override OEM Transponder Immobilizer Via Data (No Key Required). Interfaces directly with the latest
More informationDear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.
Owner s Manual 1 Dear Customer, Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully. User Memo: Date of purchase: Dealer name: Dealer address:
More information-SQA- SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION. -Module Number Session
-SQA- SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION -Module Number- 2210034 -Session-1994-95 -Superclass- -Title- ZJ MOTOR VEHICLE INSPECTION: TACHOGRAPHS
More informationAN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References
AN 17.4 RPM to TACH Counts Conversion 1 Preface 2 Audience 3 Overview 4 References This application note provides look up tables for the calculation of RPM to TACH Counts for use with the EMC2103, EMC2104,
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More informationWARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure
& Rectangular PowerBounce User s Manual Assembly, Installation, Care, Maintenance, and Use Instructions WARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure
More information3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810
1 of 9 3M Connector System 0.050" x 0.100" Pitch 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 Product Specification 78-5110-0074-0 Released: 10-1-10 2 of 9
More informationS T A N D A R D. ASAE S FEB04 Front and Rear Power Take-Off for Agricultural Tractors
ASAE S203.14 FEB04 Front and Rear Power Take-Off for Agricultural Tractors S T A N D A R D ASABE is a professional and technical organization, of members worldwide, who are dedicated to advancement of
More informationModel GX Spray Gun
"Teamwork & Communication" Model GX-7-400 Spray Gun Parts Identification Manual 17943-ID May 24, 1999 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood,
More informationSANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT
SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT This Net Metering and Interconnection Agreement ( Agreement ) is made and entered into as of this day of, 2018, by the City of Santa
More informationElectron Positron Proton Spectrometer for use at Laboratory for Laser Energetics
LLNL-TR-427769 Electron Positron Proton Spectrometer for use at Laboratory for Laser Energetics S. L. Ayers April 13, 2010 Disclaimer This document was prepared as an account of work sponsored by an agency
More information