EM-MPO/400. Multi-parameter Electricity Meter. Installation Instructions. Important: Retain these instructions. Mounting Requirements H O 2

Size: px
Start display at page:

Download "EM-MPO/400. Multi-parameter Electricity Meter. Installation Instructions. Important: Retain these instructions. Mounting Requirements H O 2"

Transcription

1 I V E I V E I V E Multi-para Electricity Meter Important: Retain these instructions Contents 1 Unpacking Storing Installation Disposal Unpacking I V E G Storing -25 C -23 F +7 C +158 F H O 2 <75 %RH 3 Installation 1 Mounting Requirements It is recommended that the installation should comply with the HSE Memorandum of Guidance on Electricity at Work Regulations mm (3.78 ) 83.5 mm (3.29 ) -1 C +14 F +65 C +149 F I V E 96 mm (3.78 ) H O 2 <75 %RH rotection I54 I V E G2118 Issue 3, 6-May-214 1

2 O OK RX V Mounting Requirements (continued) Use with either the EMIC or IQ3/XNC/SER (with MODUS driver) 2.5 m (9 1 ) cable supplied with EMIC EMIC IQ3/XNC/SER (MODUS DRIVER) I V E RS485 2 anel thickness 1 mm (.4 ) to 4 mm (.16 ) repare anel 92 mm (3.62 ) 3 Mount Meter 92 mm (3.62 ) 92 mm +.8 mm -. mm Square ( Square) I V E Slide on 4 clips (supplied) push against panel 4 Connect ower Input to Meter 23 Vac 5/6 Hz ±15 5 W maximum L N 1 2 O I O L ~ N 23 Vac DO NO SWICH ON Single part screw terminals, maximum cross section area cable 4 mm 2 (12 WG) Note that this instrument does not require an earth (ground) connection 2 G2118 Issue 3, 6-May-214

3 5 Connect Measurement Connections O Single part screw terminals, maximum cross section area cable 4 mm 2 (12 WG) 3 phase 3 or 4 wire - Star or Delta (can use Vs) nominal current: 5, nominal voltage: 23 Vac (phase to neutral), 4 Vac (phase to phase) rogrammable: Cs primary: 5 to 25 k, CSENSORS: primary 5 to 8 Vs primary: 11 V to 44 kv () 55 kv (e) Single phase (can use V) Note that uses Cs, e uses current sensors (CSENSOR) - see step 6 3 phase high voltage using 2 Vs and 2 Cs (EM-MO/35 only) 3 phase using 2 Cs - Delta (EM-MO/35 only) G2118 Issue 3, 6-May-214 3

4 6 Ensure Cs and CSENSORs have Correct olarity S1 (+) red S2 (-) lack 1 2 Supply Load Current C S2 (-) white (black/white) S1 (+) black Supply 1 2 Load Supply 1 2 S1 (+) lack Load K L Current K L Current S2 (-) White (lack/white) CSENSOR 1, 1 CSENSOR 15, 4, 8 = rimary S = Secondary Ensure connection to a has correct polarity. C (rend): +(red), - (black); CSENSOR (rend):+(black),-(white or black/white). Ensure current passes through C or CSENSOR in correct direction. Ensure C or sensor is connected to same phase as associated V.. 7 Mount EMIC or IQ3.../XNC/SER EMIC,G2182, Section 3.1 steps 1 to 6 OR IQ3xcite,G2626, IQ3xact,G2766, IQ3/XNC,G2911 IQ3/XNC MODUS Drivers Manual,E G2118 Issue 3, 6-May-214

5 Connect ulse Outputs If required 1 m ac/dc max., 1 V ac/dc max.,.5 W max load ulse 1 ulse 1 kwh Monitor O olarity independant 14 Note: ulse Rate (value of each pulse - kwh, kvrh), ulse Length (duration - s) settable in step ulse 2 ulse 2 kvrh Monitor 9 Connect to EMIC If using EMIC Single part screw terminals, maximum cross section area cable 4 mm 2 (12 WG) 2.5 m (9 1 ) cable supplied with EMIC EMIC O O EMIC RJ45 ort 1 V terminator lack Orange Red lack Data + Data - Red observe correct polarity Orange terminator For runs >3 m use 15 ohm terminators each end. Maximum length is 1 96 aud, with 26 WG cable Maximum number of s (8, 16, 32 dependent on EMIC version). G2118 Issue 3, 6-May-214 5

6 OK RX V Connect to IQ3../XNC/SER (for MODUS Driver) If using MODUS driver IQ3/XNC/SER (MODUS DRIVER) O RS485 IQ3/XNC/SER R R V integral terminator observe correct polarity terminator For runs >3 m use 12 ohm terminators each end. Maximum length is 1 96 aud, with 26 WG cable 11 Switch On O I 6 G2118 Issue 3, 6-May-214

7 12 Configure Meter I V E 5 s Operating Manual, E21116 ages aras Default Note COdE Security code (not Set Up) Ct ri C (CSENSOR) primary 2 1,3 t ri V L-L Voltage ransformer rimary 4 V 2,3 MD ER Min ower Mean Demand Integration eriod -vg ER SEC Current/Voltage ime veraging eriod SEt HRS Run kw Hours Run Set oint 1 4 ULS RtE kwh ulse Rate.1 kwh 5 ULS LEn ulse Length.1 s 5 ULS test HLd ulse Output est r aud Rate 96 6 ddr Unique Modbus ddress 25 ress E, to increase, decrease value respectively Notes: 1., C set values 5 to 25 k. EM-MO/35e,CSENSOR values 5, 5, 1, 15, 4, 8 2. If no V, set to 4 (set scale to 1). If V fitted and primary volts <6 kv, set Nominal Volts to V primary (set scale to 1). If V fitted and primary volts >6 kv, set Nominal Volts to 66 (set Scale to primary volts/66) Note that Scale is set over MODUS. [Readable voltage range: (11 V to 44 kv) e (11 V to 55 kv)] 3. Fine adjust Nominal volts and C primary ( only) allows settings other than those in default tables. I enters and exits Fine djust (icon=f). 4. he hours run set point is the kw level above which the hours run counter will increment. 5 he ulse Rate sets the value of each pulse in kwh - pulse 1, kvrh - pulse 2 (range 1 to 1 counts of register). he ulse Length is the pulse duration in secs (range.1 to 2 s) 6. Set baud rate to match controller (and other s), can be set to 4k8, 9k6, 19k2 baud. Note that protocol fixed at MODUS RU (IEEE) with 16 bit CRC, 8 bit + start bit+ stop bit, no parity G2118 Issue 3, 6-May-214 7

8 OK RX V X RX RS/XEN CS/RXEN Configure MODUS Driver If using MODUS driver he MODUS driver needs to be configured to read the. his requires understanding the communication codes for the paras to be read. IQ3/XNC MODUS Driver Manual, E2111. MODUS Communications Manual, E N L3 L2 L1 Check System Load EMIC V kw ux Input Volts C1 C2 C3 LS L N Ln L1 L2 L O Either Or IQ3/XNC/SER (MODUS DRIVER) V kw 4 Disposal WEEE Directive: t the end of their useful life the packaging and product should be disposed of by a suitable recycling centre. Do not dispose of with normal household waste. Do not burn. lease send any comments about this or any other rend technical publication to techpubs@trendcontrols.com 214 Honeywell echnologies Sàrl, ECC Division. ll rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell echnologies Sàrl, Ecublens, Z.. La ièce, 16, 118 Rolle, Switzerland by its uthorized Representative. rend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. rend Control Systems Limited lbery House, Springfield Road, Horsham, West Sussex, RH12 2Q, UK. el:+44 () Fax:+44 () rend Control Systems US th venue NE, Redmond, Washington 9852, US. el:(425) Fax:(425) G2118 Issue 3, 6-May-214

HMM Series Mechanical Heat Meters

HMM Series Mechanical Heat Meters Mechanical Heat Meters Important: Retain these instructions These instructions shall be used by trained service personnel only If the equipment is used in a manner not specified by these instructions,

More information

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32)

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32) MV Rotary Valve ctuators FOR COTROL LL VLVES VG (D5 TO D) PPLICTIO MV m Control Valve Rotary Valve ctuators are used with the VG -way and the VG -way Control all Valves to control hot and chilled water

More information

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves V5422L / V5422E CTUTED UTTERFLY VLVES SPECIFICTION DT FETURES With factory-mounted electric actuator Centric butterfly valve with elastomer liner Wide DN range (DN250 through DN400) For heating water containing

More information

PQube 3 Modbus Interface

PQube 3 Modbus Interface PQube 3 Modbus Interface Reference manual Revision 1.9 Modbus Interface Reference Manual 1.9- Page 1 Table of Contents 1. Background... 3 2. Basics... 3 2.1 Registers and Coils... 3 2.2 Address Space...

More information

premier product range

premier product range premier product range PREMIER is a full four quadrant metering platform for use in deregulated markets where data storage, multi utility and AMR facilities are important. PREMIER provides solutions from

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves V5422L / V5422E CTUTED UTTERFLY VLVES SPECIFICTION DT FETURES With factory-mounted electric actuator Centric butterfly valve with elastomer liner Wide DN range (DN250 through DN400) For heating water containing

More information

PB-600 series. Jameco SKU Number: W Single Output Battery Charger SPECIFICATION MODEL

PB-600 series. Jameco SKU Number: W Single Output Battery Charger SPECIFICATION MODEL .. Jameco SKU Number: 24381 600W Single Output Charger B-600 series SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 2) OTHERS NOTE BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE

More information

Electrical Power Electric power electrical electric power Electric power electric electric

Electrical Power Electric power electrical electric power Electric power electric electric Power Calculations Electrical Power Electric power is the rate at which electrical energy is transferred by an electric circuit. The SI unit of power is the watt, one joule per second. Electric power is

More information

MT4-024/MT4-230 MT8-024/MT8-230

MT4-024/MT4-230 MT8-024/MT8-230 Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS PRODUCT DT FETURES No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES) MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw 30A 208V 20A 208V 3 Phase 30A 208V 3 Phase Important Information Specifications Installation & Operation Outline & Wiring Drawings

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

OPERATING INSTRUCTIONS ECON-M

OPERATING INSTRUCTIONS ECON-M OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0

More information

EM DC Multi-Function DC Energy Meter

EM DC Multi-Function DC Energy Meter Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk Electro Controls Damper Actuators / Valve Motors - 2017 WattsIndustries.co.uk Damper Actuators / Valve Motors Section 21 DAMPER / VALVE MOTORS 4Nm 2 & 3 POINT EK4.. These small motors can be fitted directly

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Serial adapter 1.0 V10 Fadec to serial comunications

Serial adapter 1.0 V10 Fadec to serial comunications Serial adapter 1.0 V10 Fadec to serial comunications Users Guide. Torrent d en Puig, 31. 08358, Arenys de Munt, Barcelona,Catalonia,Spain E-mail: info@xicoy.com. Fax: +34 933 969 743 web: www.xicoy.com

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

Installation Planning (or what I didn t learn at meter school)

Installation Planning (or what I didn t learn at meter school) NWEMS Harris nstitute of echnical raining nstallation Planning (or what didn t learn at meter school) Presented by Brad Harris nstallation #1 A three phase commercial customer has the following installation

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Content 1. Laserline series 3

Content 1. Laserline series 3 FT LASERLINE Series TECHNICAL DATA SHEET FT LASERLINE Series 1. Laserline series Content 1. Laserline series 3 2. Connectors 4 3. Control system 4 4. Options 5 4.1 Automatic flow control 5 4.2 FT communication

More information

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target

More information

Autoranging Industrial Multimeter

Autoranging Industrial Multimeter Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation

More information

Micro Controller based Motor Protection Relay & Motor Management System

Micro Controller based Motor Protection Relay & Motor Management System Micro Controller based Motor Protection Relay & Motor Management System Micro Controller based Motor Protection Relay :WOD-TUA Features : In built three Phase CTs Extra wide Range : 1 10 A / 7 20 A In

More information

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual DI Rail US Model: DI-US 48-5 Installation/Operation Manual Table of Contents Section age Section age Quick Start 2 1) General Information 4 Materials rovided 4 Optional quipment 4 2) Safety Information

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT Model No. PEL00582 MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page test record

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater. Manual Title: 45 User Supplement Issue: 2 Part Number: 855981 Issue Date: 5/01 Print Date: January 1989 Page Count: 8 Revision/Date: 4, 7/97 This supplement contains information necessary to ensure the

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82315 REL CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this

More information

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications POWR MOITORIG ISTLLTIO GUI H81xx H81xx nergy Meter H06 (optional mounting bracket) Installer s Specifications Insulation lass 600V Sample Rate 1280 Hz Internal Isolation 2500V Operating Temp. Range 0 to

More information

MT4-024/MT4-230 MT8-024/MT8-230

MT4-024/MT4-230 MT8-024/MT8-230 Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS FETURES PRODUCT DT No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX SR 50 W Combined emergency lighting LED Driver Product description Independent fixed output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting function

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent

More information

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines EM readyapply SELFTEST W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For T fluorescent lamps ow-profile casing ( x 0 mm cross-section) -year guarantee Properties or h rated

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL S000 / S000 SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR MODULATING AND FLOATING CONTROL GENERAL These direct-coupled damper actuators provide modulating / floating control for:

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

100W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT.

100W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT. 100W Single Output Switching ower Supply LN-100 series MODEL:LN-100-48 OUTUT FUNCTION TEST NO TEST ITEM SECICTION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 200 mvp-p (Max ) I/: 230VC O/: 95% LOD

More information

Acuvim-L Series. Multifunction Power Meter. Max & Min

Acuvim-L Series. Multifunction Power Meter. Max & Min Series Multifunction Power Meter TRUE-RMS MEASURING OVER/UNDER LIMIT ALARM Max & Min MAX & MIN RECORD POWER QUALITY ANALYSIS TOU, 4 TARIFFS, 12 SEASONS 14 SCHEDULES Metering of Distribution Feeders, Transformers,

More information

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

DC-132 Non Spring Return Electronic Actuator Series

DC-132 Non Spring Return Electronic Actuator Series Delta Control Products, Inc. West Rose Garden Lane Phoenix, Z 857 6-78-48 DC- Non Spring Return Electronic ctuator Series Description This 4 Vac, non-spring return electronic actuator is designed for modulating

More information

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control Document No. 155-314P25 EA 599-16 Description Features Application Product Numbers The Powermite 599 MT Series SSC81U and

More information

30W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

30W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT 30W Single Output Switching ower Supply LN-30 series MODEL:LN-30-12 OUTUT FUNCTION TEST NO TEST ITEM SECIFICTION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 2 Vp-p (Max ) I/: 230VC O/: 100% LOD V1:

More information

VSD Series II Variable Speed Micro Drives

VSD Series II Variable Speed Micro Drives VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD

More information

DL8FM-TW INSTALLATION INSTRUCTIONS

DL8FM-TW INSTALLATION INSTRUCTIONS DL8FM-TW INSTALLATION INSTRUCTIONS INDEX: WIRING INSTRUCTIONS... G 2-4 DOOR LOCKS/UNLOCKS... G 4-8 HI-JACK ROGRAMMING... G 9 LED STATUS INDICATOR... G 9 SHOCK SENSOR... G 9 NEG(-) HORN HONK OUTUT... G

More information

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Document No. 155-313P25 EA 599-15 Description The Powermite 599 MT SSC61U and SSC61.5U series of electronic valve actuators

More information

Controls / Terminal Blocks Controls. CXS Series Special Cam Switches (IEC 947-3) Special Cam Switches CXS Series Features

Controls / Terminal Blocks Controls. CXS Series Special Cam Switches (IEC 947-3) Special Cam Switches CXS Series Features F Controls / Terminal Blocks Controls CXS Series Special Cam Switches (IEC 947-3) IEC 947-3 Special Cam Switches CXS Series Features SAMWHA CXS Series Cam Switches are used for non hazardous area. Functionally

More information

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc 707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20

More information

30W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

30W Single Output Switching Power Supply MODEL:PLN OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT 30W Single Output Switching ower Supply LN-30 series MODEL:LN-30-36 OUTUT FUNCTION TEST NO TEST ITEM SECIFICTION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 4.5 Vp-p (Max ) I/: 230VC O/: 100% LOD

More information

IsoLED FLEX I CUSTOMER MANUAL

IsoLED FLEX I CUSTOMER MANUAL IsoLED FLEX I CUSTOMER MANUAL 1 IsoLED FLEX I CUSTOMER MANUAL Document No. OM-1221-C Version 1.0 AUGUST 14, 2015 ISOLUX LLC 1045 Collier Center Way Suite 6 Naples FL, 34110 2 TABLE OF CONTENT TABLE OF

More information

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply www.eaton.com/dxups USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply CONTENTS 1.Brief introduction 1 1.1 System and model description 1 1.2 Description of commonly used symbols

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM93N DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THE SERVICING INSTRUCTIONS DESCRIBED WITHIN THIS MANUAL ARE FOR USE BY QUALIFIED

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

TrustSight LED Emergency Lighting

TrustSight LED Emergency Lighting TrustSight Emergency Point 15-55 V 3 W Datasheet TrustSight LED Emergency Lighting TrustSight Point 15-55 V 3 W The application of LED technology within the lighting sector also requires integration of

More information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS Date of last update: Apr-15 Ref: D7.8.4/0112-0415/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors...

More information

TrustSight LED Emergency Lighting

TrustSight LED Emergency Lighting TrustSight Emergency ar 20-95V 3W/6W Datasheet TrustSight LED Emergency Lighting TrustSight ar 20-95V 3W/6W The application of LED technology within the lighting sector also requires integration of reliable

More information

Hydraulic Surface Grinder Control Valve

Hydraulic Surface Grinder Control Valve Hydraulic Surface Grinder Control Valve Mechanically Operated Direction Valve Solenoid ilot Operated Directional Valve Double Way-hrottle Control Valve For Dresser Mounted on Wheel Head hrottle Control

More information

Jameco SKU Number:

Jameco SKU Number: Jameco SKU Number: 2105842 60W Single Output with Battery Charger(US Function) SC-60 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE OUTUT NUMBER

More information

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control Technical Instructions Document No. 155-313P25 EA 599-15 EA1157R1 Description The Powermite 599 MT SSC61U and SSC61.5U

More information

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

LEAD ACID BATTERY CHARGER

LEAD ACID BATTERY CHARGER LEAD ACID BATTERY CHARGER MODEL NO: LA4 & LA6 OPERATION & MAINTENANCE INSTRUCTIONS LS1214 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger. Please read this manual thoroughly, before attempting

More information

A 601 A B C. 1. How it works

A 601 A B C. 1. How it works 601 W4 DXN6P25 Variable flow-control 6-way valve, series DXN6_ For 4-pipes climate ceilings with change-over Pressure independent variable flow-control Integrated flow measurement Power supply U v : 24Volt

More information

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166 first issue : 2011-02-07 S FOR MSD Platinum LAMP SYSTEMS last change : 2013-01-11. MSD Platinum 15 R 9281 916 05300 number of pages : 12 Philips Innovative Applications N.V. Specifications subject to change

More information

MaxLite LED UTILITY WRAP FIXTURES

MaxLite LED UTILITY WRAP FIXTURES General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter PowerCommand ModLon II Gateway ModBus LON Converter Description The PowerCommand ModLon II Gateway is used to interface PowerCommand networks to devices and systems that communicate in Modbus communication

More information

Constant Voltage/Constant Current Test System

Constant Voltage/Constant Current Test System Description Constant Voltage/Constant Current Test System The Constant Voltage/Current Test System may be used for constant voltage or constant current pulse testing of automotive and aerospace igniters,

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik 4000 Series Modular remote I/O Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin utility

More information

82170/ /2-way diaphgram valves

82170/ /2-way diaphgram valves > > ort size: DN 8... 50, G1/4... 2 (ISO G/NT) > > For high contaminated fluids > > Solenoid hermetically sealed from fluid > > Compact valve for industrial applications > > Small dimension > > Vacuum

More information

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series Driver LC 150W 200 1050mA IND sl EXC EXCITE series Product description Constant current built-in Driver for LED, particularly suitable for industrial applications in tough environments such as cold warehouses

More information

TE2010-GE Instructions manual

TE2010-GE Instructions manual TE2010-GE Instructions manual Hardware: 3.1-4.0 Software: 3.7 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is

More information