FINAL-ER 42 Electrician Regulations Answer Schedule

Size: px
Start display at page:

Download "FINAL-ER 42 Electrician Regulations Answer Schedule"

Transcription

1 FINAL-ER 42 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker can exercise their discretion and decide on the overall accuracy of any answer that is presented in the candidate s own words. 3. Symbols and terms - alternatives Power W or P Voltage V or E or U Phase Active Question 1 Marks Reference Marking notes (a) Any TWO of: The fittings are impaired ESR 20(2)(a) Fittings are installed in such a way that any designed cooling conditions are impaired. Fittings that cause or are subject to high temperatures are placed in such a position so as to create a source of ignition. There is insufficient space, access and lighting to operate, maintain, repair, test or inspect the fittings in a safe manner If the Secretary believes on reasonable grounds that a fitting. is electrically unsafe, the Secretary may prohibit the fitting being installed. ESR 20(2)(e) ESR 20(2)(f) ESR 20(2)(i) ESR 87(1) FINAL-ER 42 ANSWERS 25 JUNE

2 Question 1 Marks Reference Marking notes (b) Any TWO of: The name of the person so notifying and the place at which that person may be contacted (including where possible a telephone number and facsimile number): The place, date, and time of the accident: A complete description of the accident: A description of any injuries, damage, or losses resulting from the accident: Where known, the names and contact information of any witness, investigator at the scene, or other person who could provide cogent information on the accident: Possible causative factors (if any are known): Any resuscitation applied, including the method, the length of time applied, the reason for discontinuing, and the person that applied the resuscitation: Any associated equipment involved, including the type, whether or not it operated correctly, and any reasons why it did not operate correctly: The condition of the associated equipment involved, including its age: Where known, the name, age, sex, occupation, and residential address of the victim. ESR 112 (1) FINAL-ER 42 ANSWERS 25 JUNE

3 Question 1 Marks Reference Marking notes (c) ANY ONE of: Where unexpected opening of the circuit could cause a danger greater than overload. Provided that the conductor is not situated in a location presenting a fire risk or a risk of explosion. Provided that the conductor is not situated where requirements for special installations and locations specify different conditions and the conductor is located on the load side of a change in current-carrying capacity that is effectively protected against overload by a protective device placed on the supply side of the origin of the conductor. Provided that the conductor is not situated where requirements for special installations and locations specify different conditions and the conductor supplies electrical equipment that is not capable of causing an overload current and the conductor has no branch circuits or socket outlets connected between the origin of the conductor and the electrical equipment. Provided that the conductor is not situated where requirements for special installations and locations specify different conditions and the conductor is provided for installations for telecommunication, control, signalling, and the like : (d) Faults between live conductors (1 mark) Against voltages imported into the electrical earthing system through the supply system neutral conductor (1 mark) (e) Any ONE of: It must be outside and not above a classified zone (e) FINAL-ER 42 ANSWERS 25 JUNE

4 Question 1 Marks Reference Marking notes It must be outside a classified zone (f) Any ONE of: No (j)(i) It must have a degree of protection of IPX4. Is provided with a shield to prevent water spraying on it. Sprinkler heads are provided with suitable deflectors Sprinkler heads are of the dry type (j) Exception (g) 230 x 5% (1 mark) = 11.5V (1 mark) (h) (i) Any colour other than green, yellow, green/yellow, black or light blue Table 3.4 (ii) Green/yellow Table 3.4 (i) Any TWO of: Identified by an orange marker tape positioned above the cable. Marker signs where the cable enters or leaves the building Recorded on a plan that is located at the switchboard at which the cable originates. : (a) (b) (j) Any TWO of: Sockets outlet supplied at ELV have their voltage conspicuously marked Socket-outlets shall not accept plugs of other voltage systems. Socket-outlets shall not have a contact for a protective earthing conductor (a) FINAL-ER 42 ANSWERS 25 JUNE

5 Question 2 Marks Reference Marking notes (a) Any TWO of: Shall have a rating of not less than the full current Shall be capable of interrupting the locked-rotor or stall current of the motor Shall be capable of interrupting eight times the full load current (a) (i) (b) The isolating switch shall have a rating of not less that the control circuit current (b) (c) Where the motor is connected by a plug and socket. Where the motor is rated at not greater than 150 VA Exception (2)(i) and (iii) (d) Any TWO of: Motors associated with fire protection services in accordance with Clause Where the opening of the motor circuit could create a hazard. Shall not provided on a fire-pump motors where the operation of such devices might reduce the operating time of equipment under emergency conditions (e) To prevent the star and delta contactors closing simultaneously GK FINAL-ER 42 ANSWERS 25 JUNE

6 Question 3 Marks Reference Marking notes (a) I L = P (½ mark) 3 V L = (½ mark) 3 x 400 = 36.08A (1 mark) From Table 12, rating of 4mm 2 is 33A (½ mark) From Table 27(1) re-rating factor is 1.12 (½ mark) I max = 33 x 1.12 (½ mark) = 36.96A (1 mark) (b) Permitted voltage drop = 400 x 1.5% (1 mark) = 6 volts From Table 42, V d /A. (½ mark) = 9.71 for 4 mm 2 cable Vd = V d /A.m x I x L (½ mark) 1000 = 9.71 x x 20 (½ mark) 1000 = 7V (1 mark) (c) No. (½ mark) It does not meet the voltage drop (1½ marks) requirements. FINAL-ER 42 ANSWERS 25 JUNE

7 Question 4 Marks Reference Marking notes (a) (i) Any TWO of: Identification of the design Confirmation that the design complies with regulation 63 Identification of the supply system with which the installation is compatible. Signed by the designer of the installation. Compliance with ISO/IECV ESR 58(1) (ii) That the installation is installed in accordance with the design indentified in the declaration of conformity. (1 mark) ESR 57(2)(c) (b) (i) Verification of operation of residual current devices. (½ mark) GK Earth fault-loop impedance test (½ mark) GK (ii) Polarity tests (½ mark) GK Correct circuit connection tests (½ mark) GK (iii) Continuity of earthing (½ mark) GK Insulation resistance (½ mark) GK (iv) Mains work ESR 70(1)(c) (v) (1) The installation is electrically safe. (2) The installation complies with the Act and Regulations (1 mark) ESR 67(1)(a) (1 mark) ESR 67(1)(b) FINAL-ER 42 ANSWERS 25 JUNE

8 Question 5 Marks Reference Marking notes (a) (i) From : (½ mark) The minimum size of the main earthing conductor shall be determined from Table 5.1 in relation to the cross-sectional area of the largest active conductor of the consumers mains. (1½ marks) (ii) 10mm 2 (½ mark) : Table 5.1 (½ mark) (b) Any THREE of: Aerial conductors. Flat braided conductors. Busbars. Sheaths of MIMS cable. Conductive framework and wiring enclosures deemed to be an earthing conductor. Copper earthing conductors buried direct in the ground. Catenary wires. (3 marks) (c) No (½ mark) : Any ONE of: (1½ marks) * RCDs are not recognised as a sole means of basic protection against contact with live parts. * The use of such devices is not recognized as a sole means of protection and does not obviate the need to apply the protective measures specified in clause : : (d) Any ONE of: It shall not be used for the earthing of electrical equipment which is supplied from another switchboard : FINAL-ER 42 ANSWERS 25 JUNE

9 Question 5 Marks Reference Marking notes It shall not be used for the provision of earthing facilities for another distribution board. : FINAL-ER 42 ANSWERS 25 JUNE

10 Question 6 Marks Reference Marking notes (a) (i) (1) The socket outlet is located in a position that it is not likely to be accessed for general purposes. (2) The socket outlet is clearly marked to indicate the restricted purpose of the socket outlet and that RCD protection is not provided. (ii) Any TWO of: Install RCD at the switchboard at the origin of the final subcircuit. Install an SRCD on the bathroom socket outlet. Install an SRCD on a socket outlet upstream from the 1 st new socket outlet Exception 3(a) Exception 3(b) GK (b) It must be supplied by a dedicated circuit. It must be protected by an RCD with a maximum rated residual current of 10 ma The RCD must be positioned so that it may be reset by the patient while under treatment (3 marks) (c) (i) 30 milliamps. (1 mark) (ii) 10 milliamps (1 mark) (iii) 300 milliamps. (1 mark) FINAL-ER 42 ANSWERS 25 JUNE

11 Question 7 Marks Reference Marking notes (a) (i) Yes (½ mark) : Only the socket outlet for the connection of pool equipment is permitted. (½ mark) (b) Table 6.2 (ii) Supplied individually as a separated circuit in accordance with clause 7.4. Supplied by a residual-current device with a maximum rated residual current of 30 ma (b)(iii)(C) (b)(iii)(E) (iii) They must be designed and constructed specifically for use in a swimming pool. Have the required degree of protection Or Rated IPX8 Shall not be provided with a protective earthing conductor (a)(i) (a)(ii) (a) (b) Installed so as to prevent entry of moisture to any connection. Installed so as to prevent water siphoning system through any wiring enclosure or cable : (c) Any TWO of: Locate the electrical equipment at a distance from the pool with all plumbing connections being made of non-conductive materials. Insert metal grids or barriers in any plumbing connection between the electrical equipment and connected to the equipotential bonding system Use an RCD with a fixed rated residual current not exceeding 30 ma to protect circuits supplying Class I equipment. : (a) : (b) : (c) FINAL-ER 42 ANSWERS 25 JUNE

12 Question 8 Marks Reference Marking notes Equipment Load Group Calculation Load (A) W lighting points Group A(i) (30 x 100) 230 = 13 13A (1 mark) 10, 75W discharge lamps Group A(ii) (10 x 75) 230 = A (1½ marks) 18, 10A double socket outlets 10, 10A single socket outlets Group B = = 10A 20 = 5A 6 = 5A 20A (2½ marks) 6kW range electric Group C = x 0.5 = 13 13A (1½ marks) 6kW sauna Group D = x 0.75 = (1½ marks) 3KW heater water Group F = 13 13A (1 mark) Maximum demand 81.76A (1 mark) FINAL-ER 42 ANSWERS 25 JUNE

13 Question 9 Marks Reference Marking notes (a) (i) 200 mm Figure 4.7 (ii) 200 mm Figure 4.7 (iii) 200 mm Figure 4.7 (iv) 50 mm Figure 4.7 (b) (1) Not installed within 0.15 m of flammable materials or structural metalwork (2) Not installed within arms reach of the ground or any o0ther place a person is likely to stand. (c) Any TWO of: Installed immediately adjacent to an entrance to the room where the heater is located. Installed within the room where the heater is located. Installed on the switchboard where the room heater final subcircuit originates. (d) Clearly and permanently marking the functional switch or switches in the heated room area. Providing suitable labeling at the relevant switchboard (a) (b) : (a) (b) FINAL-ER 42 ANSWERS 25 JUNE

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011 ER42 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011 Int QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

IT 28 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (1 mark) ESR 57(3)(e)(ii)

IT 28 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (1 mark) ESR 57(3)(e)(ii) IT 28 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The

More information

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010 Candidate Code No. Result Date Int For Board Use Only ER38 Version of AS/NZS 3000 used (tick ONE Box) 2000 2007 & Amend 1 ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010 QUESTION AND ANSWER BOOKLET

More information

EST Electrical Service Technician Answer Schedule

EST Electrical Service Technician Answer Schedule EST 2075 - Electrical Service Technician Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions. A

More information

ES5 Security Theory/Regulations Answer Schedule

ES5 Security Theory/Regulations Answer Schedule ES5 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET ER52 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET ER54 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 32 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN 08 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET ER47 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Int Time Allowed: Three

More information

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET Candidate Code No. ET34 For Board Use Only Result Date Int Result Date Int ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three hours

More information

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN15 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET Candidate Code No. ET36 For Board Use Only Result Date Int Result Date Int ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET Candidate Code No. ET54 For Board Use Only Result Date Int Result Date Int ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three hours

More information

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 36 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. 1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. KYORITSU will not accept liability for any damage or injury caused by misuse

More information

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 23 June 2018 Time Allowed: 2 Hours ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION Check the label on the back of this paper to ensure you have your paper. INSTRUCTIONS READ CAREFULLY You have

More information

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

More information

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation 86 Customhouse Quay PO Box 165, Wellington 6140 New Zealand Date of publication: 1 November 2016 Issued by: Mark Wogan, Manager Energy Safety WorkSafe New Zealand Electric Vehicle Charging Safety Guidelines

More information

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET Candidate Code No. ET49 For Board Use Only Result Date Int Result Date Int ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three hours

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EST 2074 For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed:

More information

City & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to:

City & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to: City & Guilds 2381 Test 2382 Level 3 Q1 Which one of these electrical installations does BS 7671:2008 not apply to: Temporary Construction sites Distributor s Equipment Caravans Public Premises Q2 Which

More information

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines. 1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET EST 2063 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET Time Allowed: Two Hours INSTRUCTIONS READ

More information

Electrical Testing Company Pty Ltd / download at electricaltestingcompany.com.au / AS/NZS 3003:2011 Cardiac (Rev C)

Electrical Testing Company Pty Ltd / download at electricaltestingcompany.com.au / AS/NZS 3003:2011 Cardiac (Rev C) AS/NZS 3003:2011 Cardiac Protected Electrical Areas (shall comply with Section 2 and Section 4 of the standard) The following is a guide for electricians involved with electrical installations for patient

More information

The Impact of the 18 th edition (BS 7671:2018)

The Impact of the 18 th edition (BS 7671:2018) The Impact of the 18 th edition (BS 7671:2018) In this article, Geoff Cronshaw looks at some of the proposed changes in the DPC (draft for public comment) for electrical installations, focusing on Section

More information

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013. GOVERNMENT OF INDIA CENTRAL ELECTRICITY AUTHORITY (MINISTRY OF POWER) 6 th Floor (N), Sewa Bhawan, R. K. Puram, New Delhi-110066 Tel. Fax: 26103246, e.mail: celegal-cea@gov.in, website: www.cea.nic.in

More information

LEP ASSESSMENT REVIEW

LEP ASSESSMENT REVIEW LEP ASSESSMENT REVIEW FOR SURNAME: NAME: ASSESSMENT DATE: Candidate: Assessor: Final Mark NOTE: Question 1 is a negative marking system. Start with 35 marks and marks are deducted from 35 if mistakes or

More information

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show. 1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EST 2075 For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed:

More information

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES MINISTRY OF LABOUR, INDUSTRIAL RELATIONS AND EMPLOYMENT GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES Occupational Safety & Health Inspectorate These guidelines should be used with approved standards:

More information

Electrical Testing Company Pty Ltd / / AS/NZS 3003:2011 Body (Rev E)

Electrical Testing Company Pty Ltd /  / AS/NZS 3003:2011 Body (Rev E) AS/NZS 3003:2011 Electrical Testing Company Pty Ltd / www.electricaltestingcompany.com.au / AS/NZS 3003:2011 Body (Rev E) Body Protected Electrical Areas (shall comply with Section 2 and Section 3 of the

More information

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test Initial and Periodic Inspection and Testing of Electrical Installations (2391-052) Sample Test Version 1.1 January 2018 Please note this is not a complete sample theory exam, this document consists of

More information

Wilkins Safety Group

Wilkins Safety Group H & S Guidance - Electricity INTRODUCTION Each year there are almost 1000 reportable accidents at work due to contact with electricity including a significant number of fatalities (about 20 a year). Even

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) Author: IET Publications (edited by Mark Coles) Book details Author: IET Publications (edited by Mark Coles) Year: 2011 Format: Paperback,

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int ES5 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL WORKERS REGISTRATION BOARD ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2005 QUESTION AND ANSWER BOOKLET

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001 CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS

More information

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS 717.1 Scope The particular requirements of this section apply to a.c. and d.c. installations for mobile or transportable

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Low Voltage Power Supplies in Electrified Areas

Low Voltage Power Supplies in Electrified Areas Low Voltage Power Supplies in Electrified Areas Synopsis This document mandates requirements for control of return and stray currents and the management of earthing for low voltage power supplies in electrified

More information

EARTHING YOUR QUESTIONS ANSWERED

EARTHING YOUR QUESTIONS ANSWERED 18 EARTHING YOUR QUESTIONS ANSWERED By Geoff Cronshaw What are earthed and unearthed systems? What are the requirements of BS 7671? What are the advantages and disadvantages of the various types of earthing

More information

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections One-Line / Riser Diagrams Drawings are not reviewed prior to submission. Because of

More information

MASTER ELECTRICIANS 2018 WIRING RULES ROADSHOWS

MASTER ELECTRICIANS 2018 WIRING RULES ROADSHOWS New text Deleted text Comment Reference MASTER ELECTRICIANS 2018 WIRING RULES ROADSHOWS BERNIE MCLAUGHLIN Chief Executive Officer Master Electricians NZ 027 450 4063 04 494 1540 bernie@masterelectricians.org.nz

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

WIRING MATTERS SEPTEMBER 2018

WIRING MATTERS SEPTEMBER 2018 WIRING MATTERS SEPTEMBER 2018 The 18 th Edition (BS 7671:2018) launch - revisited This is the second of two articles on the launch of the 18 th Edition (BS 7671:2018). The first article covered electric

More information

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University Safety Office Reviewed: 17 July 2012 Reviewed: DD Month University Code of Practice for Electrical Safety PART B - Design and Construction of Electrical Equipment within the University The purpose of this

More information

Small craft Electrical systems Alternating current installations

Small craft Electrical systems Alternating current installations Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 13297 Fourth edition 2014-12-01 Small craft Electrical systems Alternating current installations Petits navires Systèmes électriques Installations

More information

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.

More information

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting The Electrical Contractors Association SELECT MEMBERSHIP NUMBER 15019 ELECTRICAL INSTALLATION CERTIFICATE (REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - BS 7671 [IET WIRING REGULATIONS]) EI Copyright The

More information

Investigation into UK socket-outlets incorporating USB charging points

Investigation into UK socket-outlets incorporating USB charging points Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

Technical Manual POD Point

Technical Manual POD Point Technical Manual POD Point Solo Charger User Guide How to use your POD Point Solo It couldn t be easier. To start charging, plug in your car and wait for the light to go green. To end your charge at any

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

CAL/OSHA ELECTRICAL LOW VOLTAGE

CAL/OSHA ELECTRICAL LOW VOLTAGE Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to electrical exposure to low voltage (less than or equal to

More information

2018 B. A Guide to AS/NZS 3003: 2018 Electrical Installations Patient Areas CARDIAC. Electrical Testing Company Pty Ltd

2018 B. A Guide to AS/NZS 3003: 2018 Electrical Installations Patient Areas CARDIAC. Electrical Testing Company Pty Ltd 2018 B A Guide to AS/NZS 3003: 2018 Electrical Installations Patient Areas CARDIAC Electrical Testing Company Pty Ltd AS/NZS 3003:2018 2018 B Cardiac Protected Electrical Areas (shall comply with Section

More information

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2 Electrical Learning Notes MODULE 2.2 UNIT 2.2.6 Installation Techniques Earthing & Bonding PHASE:2 Table of Contents INTRODUCTION... 3 DEFINITIONS... 4 EARTHING... 5 TYPES OF SYSTEM EARTHING... 10 EQUIPOTENTIAL

More information

The impact of the 18 th Edition (BS 7671:2018) Sections 722, 753 and [new] 730

The impact of the 18 th Edition (BS 7671:2018) Sections 722, 753 and [new] 730 The impact of the 18 th Edition (BS 7671:2018) Sections 722, 753 and [new] 730 In this article, Geoff Cronshaw looks at the impact that some of the proposed changes in the DPC (draft for public comment)

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5 Page 1 of 5 Title Demonstrate and apply knowledge of theory and practice for registration of electrical workers (stage 3) Level 4 Credits 3 Purpose This unit standard is for people who are completing an

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH BUILT-IN FLOAT SWITCH MODEL NO: PSV5A PART NO: 7236046 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 iss 3 INTRODUCTION Thank you for purchasing this CLARKE

More information

part three electrical installations

part three electrical installations part three electrical installations Cleat Hitch Faulty electrics, or poorly installed electrical systems, can be a real hazard and could place you and others at risk. This part of the Standards aims to

More information

Demonstrate knowledge of electrical theory for Electrical Service Technician B

Demonstrate knowledge of electrical theory for Electrical Service Technician B Demonstrate knowledge of electrical theory for Electrical Service Technician B 10937 version 4 Page 1 of 5 Level 3 Credits 3 Purpose 'Electrical Service Technician B' (EST B) refers to a class of electrical

More information

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH. Instruction Manual for Heating Cables and Cold Leads Type 68994- and 68997- Catalogue no. 68994- and 68997- Hemstedt GmbH Schleicherweg 19 D-74336 Brackenheim-Botenheim Phone +49 (7135) 9898-0 Fax +49

More information

Photovoltaic Solar Plan Review

Photovoltaic Solar Plan Review PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check

More information

Key elements of the AS3000 Wiring standards and some of the recent changes.

Key elements of the AS3000 Wiring standards and some of the recent changes. Key elements of the AS3000 Wiring standards and some of the recent changes. Dean of Engineering Steve Mackay Worked for 30 years in Industrial Automation 30 years experience in mining, oil and gas, electrical

More information

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI) Chapter 5 Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI) Imagine That Engineering Inc. has adopted this program for equipment

More information

Guidance for Low Voltage Electrical Installations

Guidance for Low Voltage Electrical Installations Guidance for Low Voltage Electrical Synopsis This document provides information in support of GI/RT7007 Low Voltage Electrical. Signatures removed from electronic version Submitted by Anne E Blakeney Standards

More information

Renewable sources of electricity a brief overview

Renewable sources of electricity a brief overview Micro generation 11 Renewable sources of electricity a brief overview THE SCOPE of the 17th Edition is wider and contains many new requirements, including additional requirements to ensure the safe connection

More information

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion Consumer Units and the 17th Edition Product Focus Meet the new regulations How to avoid confusion How to Avoid the Confusion The Rules and Regulations Explained The advent of the New 17th Edition of the

More information

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( ) Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 (2382-18) March 2018 Version 1.0 FAQs 1 18 th Edition IET Wiring Regulations 2018 FAQs When will the 18 th Edition of BS 7671

More information

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump

More information

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT This Information Sheet provides guidance on how to carry out User Checks, Formal Visual Inspections and combined Inspection and Tests on portable

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

SECTION 300 OVERHEAD SERVICE

SECTION 300 OVERHEAD SERVICE SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to

More information

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS. SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS Róbert Riedlmajer TRNAVA 2007 Unit 14 - Fundamentals of power system protection

More information

Earthing Principles. Symmetra PX 250/500 kw

Earthing Principles. Symmetra PX 250/500 kw Earthing Principles Symmetra PX 250/500 kw Table of Contents Earthing Principles... 1 Decoding the Earthing Types... 1 TN Systems... 2 Characteristics... 2 Reference to IEC/EN 60364-4-41 413.1.3... 2

More information

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 1 of 5. Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 2 Definitions 2 Not seen the definition for Inspector. But with, - Qualifications,

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

CHAPTER 2: ELECTRICAL SAFETY

CHAPTER 2: ELECTRICAL SAFETY CHAPTER 2: ELECTRICAL SAFETY 2.1 Physiological Effect of Electricity 2.2 Macroshock and Microshock Macroshock Microshock 2.3 Approaches toward Protection against Shock 2.4 Medical Safety Test Electrical

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

A Guide to AS/NZS 3003: 2018

A Guide to AS/NZS 3003: 2018 2018 Electrical Testing Company Pty Ltd A Guide to AS/NZS 3003: 2018 Electrical installations Patient areas (Body and Cardiac) Subject Page AS/NZS 3000 Wiring Rules requirement Classification of Patient

More information

SINGLE PHASE WIRING SPECIFICATIONS

SINGLE PHASE WIRING SPECIFICATIONS SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425

More information

Electrical Equipment and Terminology

Electrical Equipment and Terminology Youth Explore Trades Skills Description Understanding the language of the electrical trade and knowing what electrical equipment is named and its purpose are very important. Anyone who is exposed to a

More information

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 PART NO: 7160050 OPERATION & MAINTENANCE INSTRUCTIONS GC0816 INTRODUCTION Thank you for purchasing this CLARKE Pump. The DFTP230 pump is a self-priming rotary

More information

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers: TT402 (300W) Incandescent Wireless receiver Inline Dimmer Product Description The TT- 402is a 40-300W dimmable wireless receiver. It can be paired with only circuits 1 and 2 (keys 4 or 5) on the Taptile

More information

THREE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425

More information

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33 CS ENERGY OPERATIONS PROCEDURE FOR MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33 Responsible Officer: Electrical Services Engineering Manager Responsible Manager: Group

More information

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1 SAFETY FACT SHEETS Electrical Hazards Safety Non Negotiable G-HS-ST-00752 Electrical Hazards Safety Non-Negotiables (SNN) Zinfra Group is committed to providing a safe workplace in line with our number

More information