1 Living Environment Systems 2017 Price List

2 Welcome to Mitsubishi Electric Living Environment Systems Mitsubishi Electric Living Environment Systems is a market leader in providing solutions to cool, heat, ventilate and control our buildings. As a major manufacturer of some of these pivotal technologies, we hold the UK's energy challenges close to our heart. We want to help the nation achieve its climate goals; we want to help individuals and businesses reduce the energy consumption of their buildings, whilst also helping to reduce their annual running costs. Founded in 1921, with many of those years spent at the forefront of the air conditioning industry, we have led the way in the use of innovative, energy efficient, heat pump technology. Mitsubishi Electric has evolved, and today our areas of epertise go way beyond advanced air conditioning systems that formed the foundation of our business. Here in the UK, our Living Environment Systems division provides advanced solutions that cool, heat, ventilate and control buildings in the most energy efficient and cost effective ways possible. With performance and efficiency central to our business, we are leading the way to a more sustainable future through high performance products and controls that maimise comfort, minimise cost and reduce carbon emissions. Through our technical epertise, long eperience and innovative product range, we enable buildings everywhere to significantly improve energy efficiency, reduce running costs and adhere to increasingly tough legislation. Towards a better use of energy in buildings A strong commitment to the environment remains a longterm goal of Mitsubishi Electric under its global framework for realising a sustainable planet Environmental Vision In the UK, this vision translates into our Green Gateway philosophy which is central to the way we do business. With this initiative, we are seeking to use our position as a manufacturer of key technologies to increase awareness and improve energy use in the built environment. By constantly challenging everyone involved to combat the issues we all face and encourage constructive dialogue throughout the industry, we aim to help everyone address their energy use and to work towards a more sustainable future. Working within the construction industry in this way and developing energy efficient cooling, heating and ventilation solutions all managed by the most advanced control systems available. At Mitsubishi Electric we believe we can truly make a world of difference. Air Conditioning Heating Ventilation Controls Services

3 Contents Air Conditioning Heating Ventilation Controls Services 1 2 5

4 Air Conditioning

5

6 Energy Efficient Air Conditioning Systems The need for air conditioning Today s commercial buildings are increasingly air tight and filled with heat generating office equipment and lighting, which presents a problem for anyone trying to maintain a stable and comfortable internal environment. With buildings accounting for around half of all UK greenhouse emissions, legislation is demanding higher standards of air quality and increased energy efficiency. To reduce the impact of the built environment, the challenge is to find cooling, heating, ventilation and control solutions that match energy efficiency with complete fleibility of design and control. Our innovative and pioneering air conditioning systems offer more than double the efficiency levels of 1015 year old systems and can also be far more efficient than traditional methods of cooling and heating buildings, resulting in reduced running costs and lower carbon emissions. Todays systems can simultaneously heat and cool different spaces to balance energy use across a building and sanitary hot water can even be supplied from the same system Air Conditioning Energy Efficient Air Conditioning Systems

7 1.1.2 Air Conditioning Energy Efficient Air Conditioning Systems The benefits of our air conditioning Energy Efficient Air Conditioning Systems As a market leader, we pride ourselves in providing high performance and competitive systems with low running costs. By utilising heat pump technology, our air conditioning units not only provide cooling, but also heating and often sanitary hot water. Heat pump technology requires only a small amount of electricity to harvest, upgrade and move heat from one location to another and providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas. Outstanding benefits Efficient and etensive product range ideal for a variety of buildings, from small retail outlets, up to vast multistorey office complees Air conditioning units which can upgrade free energy from a range of natural sources including air, ground and water Our pioneering technology has led the way over the last decade with advances in energy efficiency through inverter technology, refrigerant and compressor design and control solutions We measure and report true seasonal efficiency to provide accurate performance data Dedicated Partner Programme for air conditioning installers Reliable technical support and training at every step of the way

8 Energy Efficient Air Conditioning Systems M Series Mr Slim MultiSplits City Multi Heating Only Contents 1.1. Air Conditioning Energy Efficient Air Conditioning Systems

9 M Series Room Air Conditioning

10

11 The Adaptable M Series Range Designed to cool or heat small to medium sized spaces, such as retail units and small offices, the M Series splits range provides a versatile, yet affordable air conditioning solution. Quick to install, the range includes one of the quietest units on the market. Also available in a variety of options, the M Series range fits in wherever its needed. Indoor units can be wall or floor mounted. Wall Mount Systems Floor Mount Systems Cost effective Classic Inverter series Inverter series designed to suit popular demand Stylish Zen indoor series in black, silver or white Top of the range High COP Inverter series Etremely versatile Designed for wall installation at floor level Compact design makes installation easy models available including 2.5kW5.0kW Operational Range Operation range MUZDM MUZSF/GF/FH/EF MUFZKJ Cooling 10ºC to +ºC 10 C to + C Heating 10ºC to +2ºC 15 C to +2 C Nominal Conditions: Cooling; indoor 27ºC DB, 19ºC WB; outdoor 5ºC DB, 2ºC WB. Nominal Conditions: Heating; indoor 20ºC DB; outdoor 7ºC DB, ºC WB. UK Conditions: Summer; indoor 21ºC DB, 15ºC WB; outdoor 27ºC DB. UK Conditions: Winter; indoor 21ºC DB; outdoor 0 C DB, 1ºC WB Air Conditioning

12 The Adaptable M Series Range Contents MSZDM Inverter Heat Pump Classic Wall Mounted System MSZSF/GF Inverter Heat Pump Wall Mounted System MSZFH Inverter Heat Pump Wall Mounted System MSZEF Zen Inverter Heat Pump Wall Mounted System MFZKJ Inverter Heat Pump Floor Mounted System Accessories / Optional Etras Air Conditioning

13 1.2. Air Conditioning MSZDM Inverter Heat Pump Classic Wall Mounted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges MSZDM INDOOR UNITS MSZDM25VA MSZDM5VA CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) Heating/Cooling LoMiHiSupHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEVEL (dba) Heating/Cooling LoMiHiSupHi SOUND POWER LEVEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES.15 (0.9.) 2.5 (0.9.0) 2.1 (0.7.5) 2.8 ( ) /.52.1 / 5.8 A+ / A / (/8 ).5 (1/ ) 207 / v, Hz 10. (0.9.8).1 (1.0.7) 2.99 (0.7.98).12 (0.99.7) /.0. / 5.7 A+ / A / (/8 ).5 (1/ ) 207 / v, Hz 10 INDOOR PRICE MUZDM OUTDOOR UNITS SOUND PRESSURE LEVEL (dba) Heating/Cooling SOUND POWER LEVEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m MUZDM25VA / Fed by Indoor Unit 0.85 / / /. [5.8] MUZDM5VA 51 / Fed by Indoor Unit / / /.8 [.5] OUTDOOR PRICE SYSTEM PRICE 52

14 MSZSF/GF Inverter Heat Pump Wall Mounted System MSZSF/GF INDOOR UNITS MSZSF20VA MSZSF25VE MSZSF5VE MSZSFVE MSZGF0VE2 MSZGF71VE2 CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) Heating SilentLoMidHiShi Cooling SilentLoMidHiShi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEVEL (dba) Heating/Cooling SilentLoMiHiShi SOUND POWER LEVEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES (/8 ).5 (1/ ) / (1.0.1) 2.5 (0.9.) 2. (0.8.1) 2.5 (0.89.7) /.17. / 7. A+ / A (/8 ).5 (1/ ) / (1..).5 (1.1.8).2 (1.1.82).7 (1.1.77) /.2. / 7.2 A+ / A (/8 ).5 (1/ ) 1920 / (1.7.) 5.0 (1.5.).8 (1.1.0).9 (1.85.5) /.01. / 7.2 A+ / A (1/2 ).5 (1/ ) 2889 / (2.09.).0 (1.7.5) 5.5 (1.7.7) 5.95 (1.87.) /.1. /.8 A+ / A (5/8 ).5 (1/ ) / (2.29.9) 7.1 (2.08.7).7 (1.88.2) 7.0 (1.988.) /..2 /.8 A+ / A (5/8 ) 9.52 (/8 ) / INDOOR PRICE MUZSF/GF OUTDOOR UNITS N/A MUlTISPlIT ONlY MUZSF25VE MUZSF5VE MUZSFVE MUZGF0VE2 MUZGF71VE SOUND PRESSURE LEVEL (dba) Heating/Cooling SOUND POWER LEVEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 8 / v, Hz / / /.2 [8.] (7m) / v, Hz 1.00 / / /.9 [8.5] (7m) 52 / v, Hz / / / 7. [12.] (7m) 55 / v, Hz / / / 7.9 [1.5] (10m) 55 / v, Hz 2.20 / / / 9. [1.] (10m) OUTDOOR PRICE SYSTEM PRICE ,208 MSZSF20VA only available with MXZ MultiSplit outdoor units Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

15 1.2. Air Conditioning MSZFH Inverter Heat Pump Wall Mounted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges MSZFH INDOOR UNITS MSZFH25VE2 MSZFH5VE2 CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) Heating SLoLoMiHiShi Cooling SLoLoMiHiShi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEVEL (dba) Heating/Cooling SilentLoMiHiShi SOUND POWER LEVEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES.2 (1.85.5) 2.5 (1..5) 2.5 (1.9.57) 2.8 (1.8.7) / / 9.1 A+++ / A (/8 ).5 (1/ ) / (1.0.).5 (0.8.0). (0.85.2).7 ( ) / / 8.9 A+++ / A (/8 ).5 (1/ ) / INDOOR PRICE MUZFH OUTDOOR UNITS SOUND PRESSURE LEVEL (dba) Heating/Cooling SOUND POWER LEVEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m MUZFH25VE 9 / v, Hz / / / 2. [9.] MUZFH5VE / v, Hz / / /.8 [9.] OUTDOOR PRICE 7 5 SYSTEM PRICE 70 87

16 MSZEF Zen Inverter Heat Pump Wall Mounted System MSZEFB/S/W INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) Heating/Cooling SLoLoMiHiShi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEVEL (dba) Heating/Cooling SilentLoMiHiShi SOUND POWER LEVEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES MSZEF25VEB/S/W MSZEF5VEB/S/W MSZEFVEB/S/W.2 (1.1.2) 2.5 (1.2.) 2.5 (0.91.9) 2.8 (1.19.7) /.59.7 / 8.5 A++ / A / (/8 ).5 (1/ ) / (1.85.5).5 (1..0).2 (1.5.57).7 (1.8.97) /.85. / 8.5 A++ / A / (/8 ).5 (1/ ) / (1.7.5) 5.0 (1.5.).82 (1..2).9 (1.95.) /.21.5 / 7.2 A+ / A / (1/2 ).5 (1/ ) 079 / INDOOR PRICE MUZEF OUTDOOR UNITS SOUND PRESSURE LEVEL (dba) Heating/Cooling SOUND POWER LEVEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) OUTDOOR PRICE SYSTEM PRICE B = Black S = Silver W = White Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m MUZEF25VE MUZEF5VE MUZEFVE 8 / v, Hz / / / 2.9 [7.] / v, Hz / / /.2 [8.5] / v, Hz 1.55 / / /.9 [12.] Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

17 1.2.8 Air Conditioning MFZKJ Inverter Heat Pump Floor Mounted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges MFZKJ INDOOR UNITS MFZKJ25VE2 MFZKJ5VE2 MFZKJVE2 CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) Heating/Cooling LoMiHiSupHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEVEL (dba) Heating/Cooling SilentLoMiHiShi SOUND POWER LEVEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES. (1.2.) 2.5 (0.5.) 2.85 ( ) 2.5 (0.9.5) 0..2 /..5 / 8.5 A+ / A / (/8 ).5 (1/ ) / (1.25.5).5 (0.5.7). ( ).7 (0.9.85) /.72. / 7.8 A+ / A / (/8 ).5 (1/ ) / (2.28.2) 5.0 (1.5.7) 5.0 (1.8.8).75 ( ) 0..7 /.55. /.5 A+ / A / (1/2 ).5 (1/ ) 295 / INDOOR PRICE MUFZKJ OUTDOOR UNITS MUFZKJ25VE MUFZKJ5VE MUFZKJVE SOUND PRESSURE LEVEL (dba) Heating/Cooling SOUND POWER LEVEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m 51 / v, Hz 0.77 / / / 2.7 [9.] / v, Hz 1.11 / / /.2 [9.] / v, Hz 1.1 / / /.2 [1.0] OUTDOOR PRICE 5 57 SYSTEM PRICE 1,000 1,121 1,08

18 M Series Accessories / Optional Etras WAll MOUNTED UNITS MAC220FT MAC210FT FlOOR MOUNTED UNITS DESCRIPTION AntiAllergy Enzyme filters for MSZSF25VE2, MSZEF25VEB/S/W (10 pack) AntiAllergy Enzyme filters for MSZGF0/71VE2 (10 pack) DESCRIPTION PRICE PRICE MAC08FT AntiAllergy Enzyme filters for MFZKJ25VE2 (10 pack) 82 OUTDOOR UNITS MAC889SG MAC88SG SYSTEM CONTROl UNITS PAR2MAA MACIF MAC97IF MAC557IF PACYT52CRA IO INTERFACE MELCOBEMS MINI DESCRIPTION Air outlet guides for MUFZKJ255VE, MUZSF25/5VE, MUZFH25/5VE, MUZEF25/5VE Air outlet guides for MUFZKJVE, MUZSFVE, MUZEFVE, MUZGF0/71VE(2) DESCRIPTION Wired remote controller for MFZKJ, MSZDM, MSZSF, MSZGF, MSZEF, MSZFH Interface for group control, run fault and connection to MNET System Interface for Contact Terminal and PAR2MAA / PACYT52CRA Wired Remote Controller Interface for connection to WiFi MELCloud service Simplified wired remote controller Input/output interface Modbus/BACnet interface PRICE PRICE Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

19 Mr Slim Packaged SplitSystem Air Conditioning

20

21 The Versatile Mr Slim Range Suitable to cool or heat a huge variety of applications such as offices and retail units, our Mr Slim range is one of Britain s best selling air conditioning splitsystems. Combine the efficiency with the complete versatility that this range has to offer and the possibilities are virtually infinite. Inverter Standard Inverter Power Inverter Zubadan Inverter Cost effective Available in single and three phase outdoor units Available with four way blow cassettes from 71kW High quality cost effective Standard Inverter Available in single and three phase outdoor units S Series models from 2.5kW7kW available with four way blow cassettes, ducted or ceiling mounted indoor units Standard Inverter models from 10kW22kW available with four way blow cassettes, ducted, floor, wall or ceiling mounted indoor units Top of the range Power Inverter technology optimised for high seasonal efficiencies Available in single and three phase outdoor units 9 models available from.5kw22kw Available with four way blow cassettes, ducted, floor, wall or ceiling mounted indoor units Optimal performance at low ambient temperature conditions Quicker defrost and improved start up in heating* Available in single and three phase outdoor units 2 models available from 10kW12.5kW Available with four way blow cassettes, wall or ceiling mounted indoor units * Will work effectively even when the outdoor ambient air temperature is 25 C. At 20ºC, ma heating capacity is achieved in about 20 mins. Operational Range Operation range Size PUHZZRP PUHZP / PUHZSP PUHZSHW SUZKA / SUZSA Cooling Less than 15 C to + C 15 C to + C 15 C to + C 10 C to + C 15 C to + C 15 C to + C 15 C to + C 15 C to + C 0 or more 15 C to + C 15 C to + C 15 C to + C 15 C to + C Heating Less than 11 C to +21 C 15 C to +21 C 25 C to +21 C 10 C to +2 C 0 or more 20 C to +21 C 15 C to +21 C 25 C to +21 C 10 C to +2 C Nominal Conditions: Cooling; indoor 27ºC DB, 19ºC WB; outdoor 5ºC DB, 2ºC WB. Nominal Conditions: Heating; indoor 20ºC DB; outdoor 7ºC DB, ºC WB. UK Conditions: Summer; indoor 21ºC DB, 15ºC WB; outdoor 27ºC DB. UK Conditions: Winter; indoor 21ºC DB; outdoor 0 C DB, 1ºC WB Air Conditioning

22 The Versatile Mr Slim Range Contents PLAZP Power Inverter Heat Pump, Way Blow Ceiling Cassette System PLARP Standard Inverter Heat Pump, Way Blow Ceiling Cassette System PLAZP Zubadan Inverter Heat Pump, Way Blow Ceiling Cassette System PLASP Inverter Heat Pump, Way Blow Ceiling Cassette System SLZKF Inverter Heat Pump, 0000 Way Blow Ceiling Cassette System PKARP Power Inverter Heat Pump, Wall Mounted System PKARP Standard Inverter Heat Pump, Wall Mounted System PKARP Zubadan Inverter Heat Pump, Wall Mounted System SEZKD Inverter Heat Pump, Ceiling Concealed Ducted System PEADRP Power Inverter Heat Pump, Ceiling Concealed Ducted System PEADRP Standard Inverter Heat Pump, Ceiling Concealed Ducted System PEADRP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System PEARP Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System PEARP Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System PCARP Power Inverter Heat Pump, Ceiling Suspended System PCARP Standard Inverter Heat Pump, Ceiling Suspended System PCARPHAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System PSARP Power Inverter Heat Pump, Floor Standing System PSARP Standard Inverter Heat Pump, Floor Standing System HP DXE Power Inverter Heat Pump, Air Curtain System PACIF Air Handling Unit Controller Twin, Triple, Quad Combination Tables Accessories / Optional Etras Air Conditioning

23 1.. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PLAZP Power Inverter Heat Pump ( Phase) Way Blow Ceiling Cassette System PLAZP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiMi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMiMi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PLAZP5eA PLAZPeA PLAZP0eA PLAZP71eA PLAZP100eA.1 (1.5.2). (1..5).5 (1.5.). (1.5.15).82 /.0.90 / 7.0 A++ / A (1/2 ) /.5 (1/ ) (9) 80 (9) 258 (0) 21 / 5 PLPEA PAR2MAA / v, Hz 0.8 / / /.58 [1.0] (2.57.) 5.0 (2.5.) 5.1 (2.15.2). ( ).85 / /.90 A++ / A (1/2 ) /.5 (1/ ) (9) 80 (9) 258 (0) 21 / 5 PLPEA PAR2MAA / v, Hz 1.57 / / /.2 [1.0] (2.88.2).1 (2.7.5).0 (2.8.97) 5. ( ).70 /..0 /.70 A++ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 258 (0) 21 / 5 PLPEA PAR2MAA 8 / v, Hz 2.0 / / / 7.72 [19.0] (.510.2) 7.1 (.8.1).8 (.08.5).55 (.057.5).20 / / 7.0 A++ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 8 / v, Hz 1.99 / / / 7. [19.0] (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5).0 /.0.90 / 7.20 A++ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA INDOOR PRICe PUHZZRP5VKA2 PUHZZRPVKA2 PUHZZRP0VHA2 PUHZZRP71VHA2 PUHZZRP100VKA PUHZZRP125VKA PUHZZRP10VKA 51 / v, Hz 2.0 / / / 9.5 [2.5] OUTDOOR PRICe 900 1,082 1,179 1,229 1,58 SYSTeM PRICe 1,59 1,71 1,85 2,00 2,19 Note: Indoor price includes separate PLPEA grille and PAR2MAA wired remote controller. PLAZP125eA 1.0 (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ).81 / /.70 N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 /5 PLPEA PAR2MAA 52 / v, Hz.7 /.8.27 / / 1. [2.5] ,2 2,51 PLAZP10eA 1.0 ( ) 1. (.215.0) 1. (.8515.) 12.9 (5.71.1).07 /.07. /. N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 52 / v, Hz.8 /.5.0 / / [28.0] ,951 2,877

24 PLAZP Power Inverter Heat Pump ( Phase) Way Blow Ceiling Cassette System PLAZP INDOOR UNITS PLAZP100eA PLAZP125eA PLAZP10eA CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiMi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMiMi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE INDOOR PRICe 11.2 (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5).0 /.0.90 / 7.20 A++ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 1.0 (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ).81 / /.70 N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 /5 PLPEA PAR2MAA ( ) 1. (.215.0) 1. (.8515.) 12.9 (5.71.1).07 /.07. /. N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 92 PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PUHZZRP100YKA Phase 51 / v,Hz 2.0 / / /.2 (8.0) PUHZZRP125YKA Phase 52 / v,Hz.7 /.8.27 / / 5.9 (9.5) PUHZZRP10YKA Phase 52 / v,Hz.8 /.5.0 / /.7 (1.0) OUTDOOR PRICe SYSTeM PRICe 1,577 2,8 1,7 2,9 2,110,0 Phase Note: Indoor price includes separate PLPEA grille and PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

25 1.. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PLARP Standard Inverter Heat Pump ( Phase) Way Blow Ceiling Cassette System PLARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE SUZKA / PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) PLARP5eA PLARPeA PLARP0eA PLARP71eA PLARP100eA.1 (1.75.0). (1..9).9 (1.5.25).1 ( ).10 /..0 /.90 A+ / A (/8 ) /.5 (1/ ) (9) 80 (9) 258 (0) 19 / 5 PLPEA PAR2MAA 5.8 (1.77.2) 5.5 (2.5.).9 (1.5.12) 5.0 ( ). /.0.00 /. A+ / A (1/2 ) /.5 (1/ ) (9) 80 (9) 258 (0) 19 / 5 PLPEA PAR2MAA.9 (2.58.0) 5.7 (2..) 5.87 (2.1.80) 5.25 ( ). /.2.0 /. A+ / A (5/8 ) /.5 (1/ ) (9) 80 (9) 258 (0) 21 / 5 PLPEA PAR2MAA 8.0 (2.10.2) 7.1 (2.88.1).80 ( ).5 ( ).5 /.8.0 /.20 A+ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 258 (0) 21 / 5 PLPEA PAR2MAA 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.).1 / / 5.0 A+ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA INDOOR PRICe SUZKA5VA SUZKAVA SUZKA0VA SUZKA71VA PUHZP100VHA5 / v, Hz 1.00 / / /. (8.) / v, Hz 1.9 / / / 7.7 (12.2) / v, Hz 1.97 / / / 8.7 (1.2) / v, Hz 2.20 / / / 9.9 (1.) / v, Hz.28 / / / 1.90 (28) (20m) OUTDOOR PRICe ,118 SYSTeM PRICe 1,17 1,297 1,8 1,5 1,91 Notes: Indoor price includes separate PLPEA grille and PAR2MAA wired remote controller. No duty/standby operation on SUZKA5//0/71VA. PLARP125eA 1.0 (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ).1 /.01 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 /5 PLPEA PAR2MAA 8 PUHZP125VHA 55 / v, Hz.10 /.08.5 / / 17.2 (28) (0m) 1,2 2,079 PLARP10eA 1.0 ( ) 1. ( ) 1. (.2515.) 12.5 ( ).21 / 2.1 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 880 PUHZP10VHA 5 / v, Hz.98 / / / (29.5) (0m) 1,9 2,89

26 PLARP Standard Inverter Heat Pump ( Phase) Way Blow Ceiling Cassette System PLARP INDOOR UNITS PLARP100eA PLARP125eA PLARP10eA CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.).1 / / 5.0 A+ / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA INDOOR PRICe 81 SYSTEM POWER INPUT (kw) PUHZP100YHA Phase 5 / v,Hz.28 / / / 5.7 (1) (20m) OUTDOOR PRICe 1,191 SYSTeM PRICe 2, (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ).1 /.01 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 /5 PLPEA PAR2MAA 8 PUHZP125YHA2 Phase 55 / v,Hz.10 /.08.5 / /.2 (1) (0m) 1, 2, ( ) 1. ( ) 1. (.2515.) 12.5 ( ).21 / 2.1 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 880 PUHZP10YHA2 Phase 5 / v,Hz.98 / / / 8.02 (1) (0m) 1,01 2,81 Phase Notes: Indoor price includes separate PLPEA grille and PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

27 1..8 Air Conditioning PLAZP Zubadan Inverter Heat Pump Way Blow Ceiling Cassette System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PLAZP INDOOR UNITS PLAZP100eA PLAZP100eA PLAZP125eA CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE 11.2 (.51.0) 10.0 (.911.) 9.5 ( ) 9.2 (.510.5).2 /.5.0 / 5.5 A / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 11.2 (.51.0) 10.0 (.911.) 9.5 ( ) 9.2 (.510.5).2 /.5.0 / 5.5 A / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 / 5 PLPEA PAR2MAA 1.0 (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ).5 / / 5.1 N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (0) 2 /5 PLPEA PAR2MAA INDOOR PRICe PUHZSHW OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m 81 PUHZSHW112VHA 52 / v, Hz 2.8 / / / 11.8 [5] PUHZSHW112YHA Phase 52 / , Hz 2.8 / / /. [1] PUHZSHW10YHA Phase 52 / , Hz.88 /.5.5 / / 5.72 [1] OUTDOOR PRICe SYSTeM PRICe 2,52,9 2,709,570,155,0 Phase Note: Indoor price includes separate PLPEA grille and PAR2MAA wired remote controller.

28 PLASP Inverter Heat Pump Way Blow Ceiling Cassette System PLASP INDOOR UNITS PLASP71BA PLASP100BA PLASP100BA PLASP125BA PLASP125BA PLASP10BA PLASP10BA CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE 8.0 (2.8.9) 7.1 (2.88.1).8 (2.27.).5 (2.7.5) /.21.8 / 5. A / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 258 (5) 2 / PLPBA PAR2MAA 11.2 (.511.5) 9. (.99.9) 9.5 (.89.8) 8. (.59.1) /.01.8 / 5.1 A / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 25 / PLPBA PAR2MAA 11.2 (.511.5) 9. (.99.9) 9.5 (.89.8) 8. (.59.1) /.01.8 / 5.1 A / A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 25 / PLPBA PAR2MAA 1.5 ( ) 12. (5.51.0) 11.5 (.12.8) 11. ( ) /.01 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 25 / PLPBA PAR2MAA 1.5 ( ) 12. (5.51.0) 11.5 (.12.8) 11. ( ) /.01 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 25 / PLPBA PAR2MAA 15.5 ( ) 1.0 (5.51.0) 1.2 (.1.5) 12.0 ( ) / 2.1 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 27 / PLPBA PAR2MAA 15.5 ( ) 1.0 (5.51.0) 1.2 (.1.5) 12.0 ( ) / 2.1 N/A N/A (5/8 ) / 9.52 (/8 ) (9) 80 (9) 298 (5) 27 / PLPBA PAR2MAA INDOOR PRICe SUZSA / PUHZSP OUTDOOR UNITS SUZSA71VA PUHZSP100VHA PUHZSP100YHA Phase PUHZSP125VHA PUHZSP125YHA Phase PUHZSP10VHA PUHZSP10YHA Phase SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 55 / v, Hz 2.25 / / / 9. [1.] / v, Hz.28 / / / 1. [28.9] / v, Hz.28 / / / 5.72 [1.9] / v, Hz.11 /.09. / / 18.8 [29.0] / v, Hz.11 /.09. / / 7.18 [1.0] / v, Hz.98 / / / [0.5] / v, Hz.98 / / / 8.5 [1.0] OUTDOOR PRICe 72 1,02 1,181 1,180 1,5 1, 1,588 SYSTeM PRICe 1, 1,77 1,892 1,909 2,0 2,199 2,5 Phase Notes: Indoor price includes separate PLPBA grille and PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

29 1..10 Air Conditioning SLZKF Inverter Heat Pump 0000 Way Blow Ceiling Cassette System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges SLZKFVA2 INDOOR UNITS SLZKF25VA2 SLZKF5VA2 SLZKFVA2 SLZKF0VA2 CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) Unit / Grille ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE INDOOR PRICe.2 (1..2) 2. (1.5.2) 2.9 (1.09.5) 2.0 (1..20) /.8. /. A+ / A (/8 ).5 (1/ ) () 570 () 25 (10) 15 / SLP2FA PAR2MAA.0 (1.75.0).5 (1..9). (1..20). (1.8.8) /.0. /.5 A+ / A (/8 ).5 (1/ ) () 570 () 25 (10) 15 / SLP2FA PAR2MAA 5.0 (1.7.0). (2.5.2).20 (1.5.0).5 ( ) /.0./. A+ / A (1/2 ).5 (1/ ) () 570 () 25 (10) 15 / SLP2FA PAR2MAA. (2.57.) 5. (2..5) 5.8 ( ) 5.55 (2.28.) /.17.1 /.2 A+ / A (5/8 ).5 (1/ ) () 570 () 25 (10) 15 / SLP2FA PAR2MAA SUZKAVA OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SUZKA25VA 8 / v, Hz 0.89 / / /.2 (7.2) SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) SUZKA5VA / v, Hz 1.11 / / / 5.1 (8.7) SUZKAVA 52 / v, Hz 1.5 / / / 7.0 (12.) SUZKA0VA 55 / v, Hz 2.28 / / / 10.1 (1.) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m OUTDOOR PRICe SYSTeM PRICe , , ,81 Note: Indoor price includes separate SLP2FA grille and PAR2MAA wired remote controller.

30 PKARP Power Inverter Heat Pump Wall Mounted System PKARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEvEL (dba) SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PKARP5HAL PKARPHAL PKARP0KAL PKARP71KAL PKARP100KAL.1 (1.5.2). (1..5).5 (1.5.). (1.5.15) /.8.9 / 5.7 A / A (1/2 ).5 (1/ ) (2.57.). (2.5.).25 (2.15.2).2 ( ) /.2.0 / 5. A+ / A (1/2 ).5 (1/ ) (2.88.2).1 (2.7.7) 5.95 (2..95) 5.5 (2.5.15) /.81.2 /. A+ / A (5/8 ) 9.52 (/8 ) (.510.2) 7.1 (.8.1).8 (.08.5).55 (.057.5) /.9. /.5 A+ / A (5/8 ) 9.52 (/8 ) (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.9.1 /.1 A+ / A (5/8 ) 9.52 (/8 ) INDOOR PRICe PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PUHZZRP5VKA2 PUHZZRPVKA2 PUHZZRP0VHA2 PUHZZRP71VHA2 PUHZZRP100VKA / v, Hz 1.07 / / /.9 [1.] / v, Hz 1. / / /.59 [1.] / v, Hz 1.9 / / / 8.11 [19.] / v, Hz 2.19 / / / 7.79 [19.] / v, Hz.0 / / / 11.2 [27.1] OUTDOOR PRICe 900 1,082 1,179 1,229 1,58 SYSTeM PRICe 1,99 1,5 1,770 1,82 2,17 PKARP100KAL 11.2 (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.9.1 /.0 A+ / A (5/8 ) 9.52 (/8 ) PUHZZRP100YKA Phase 51 / v, Hz.0 / / /.0 [8.] ,577 2,295 Phase Note: Indoor price includes infrared remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

31 1..12 Air Conditioning PKARP Standard Inverter Heat Pump Wall Mounted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PKARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PKARP100KAL 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /.8 A / B (5/8 ) 9.52 (/8 ) PKARP100KAL 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /.8 A / B (5/8 ) 9.52 (/8 ) INDOOR PRICe PUHZP100VHA5 5 / v, Hz.9 / / / 1.55 [ 28.] PUHZP100YHA Phase 5 / v, Hz.9 / / / 5. [1.] OUTDOOR PRICe 1,118 1,191 SYSTeM PRICe 1,8 1,909 Phase Note: Indoor price includes infrared remote controller.

32 PKARP Zubadan Inverter Heat Pump Wall Mounted System PKARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PUHZSHW OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PKARP100KAL 11.2 (.51.0) 10.0 (.911.) 11.1 (.51.85) 9.2 (.510.5) /.2.8 / 5.2 A / A (5/8 ) 9.52 (/8 ) (.51.0) 10.0 (.911.) 11.1 (.51.85) 9.2 (.510.5) /.2.8 / 5.2 A / A (5/8 ) 9.52 (/8 ) INDOOR PRICe SYSTEM POWER INPUT (kw) PUHZSHW112VHA 52 / v, Hz.10 / / / 11.7 [5.] PKARP100KAL PUHZSHW112YHA Phase 52 / v, Hz.10 / / /.2 [1.] OUTDOOR PRICe 2,52 2,709 SYSTeM PRICe,2,27 Phase Note: Indoor price includes infrared remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

33 1..1 Air Conditioning SeZKD Inverter Heat Pump Ceiling Concealed Ducted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges SeZKDVAQ INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores SUZKAVA OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 7m SeZKD25VAQ SeZKD5VAQ SeZKDVAQ SeZKD0VAQ SeZKD71VAQ 2.9 (1..5) 2.5 (1.5.2) 2. ( ) 2.5 (1.7.1) /.2.8 / 5.2 A / A (/8 ).5 (1/ ) (1.75.0).5 (1..9).5 (1..20). (1.7.82) /.7.0 / 5. A+ / A (/8 ).5 (1/ ) (1.77.2) 5.1 (2.5.) 5.8 (1..05).99 ( ) /.2.9 / 5.7 A / A (1/2 ).5 (1/ ) (2.58.0) 5. (2..).21 ( ) 5.9 ( ) /.22.1 / 5.2 A+ / A (5/8 ).5 (1/ ) (2.10.) 7.1 (2.88.).80 ( ).95 ( ) /.21.8 / 5.2 A / A (5/8 ) 9.52 (/8 ) INDOOR PRICe SYSTEM POWER INPUT (kw) SUZKA25VA SUZKA5VA SUZKAVA SUZKA0VA SUZKA71VA 8 / v, Hz 0.80 / / /.80 [7.] / v, Hz 1.1 / / / 5.20 [8.7] / v, Hz 1.80 / / / 8.20 [12.7] / v, Hz 2.20 / / / 9.80 [1.7] / v, Hz 2.27 / / / 9.7 [17] OUTDOOR PRICe SYSTeM PRICe ,1 1,21 1,77 Note: Indoor price includes separate PAR2MAA wired remote controller.

34 PeADRP Power Inverter Heat Pump ( Phase) Ceiling Concealed Ducted System PeADRP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiMi2MiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PeADRP5JAQ PeADRPJAQ PeADRP0JAQ PeADRP71JAQ PeADRP100JAQ.1 (1.5.2). (1..5).5 (1.5.). (1.5.15) /.0.0 / 5. A+ / A (1/2 ).5 (1/ ) (2.57.) 5.0 (2.5.) 5.1 (2.15.2). ( ) /.7. / 5.5 A+ / A (1/2 ).5 (1/ ) (2.88.2).1 (2.7.7) 5.95 (2..95) 5.5 (2.5.15) /.70.1 / 5.8 A+ / A (5/8 ) 9.52 (/8 ) (.510.2) 7.1 (.8.1).8 (.08.5).55 (.057.5) /.5.9 / 5. A / A (5/8 ) 9.52 (/8 ) (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.91.2 / 5. A+ / A (5/8 ) 9.52 (/8 ) INDOOR PRICe SYSTEM POWER INPUT (kw) PUHZZRP5VKA2 PUHZZRPVKA2 PUHZZRP0VHA2 PUHZZRP71VHA2 PUHZZRP100VKA PUHZZRP125VKA PUHZZRP10VKA / v, Hz 0.95 / / /.18 [1.1] / v, Hz 1. / / / 7.09 [1.] / v, Hz 1.79 / / / 8.8 [20.] / v, Hz 2.0 / / / 8. [21] / v, Hz 2.0 / / / 11. [29.2] OUTDOOR PRICe 900 1,082 1,179 1,229 1,58 SYSTeM PRICe 1,20 1,78 1,811 1,9 2,251 Note: Indoor price includes separate PAR2MAA wired remote controller. PeADRP125JAQ 1.0 (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ) /.2.9 / 5.0 N/A (5/8 ) 9.52 (/8 ) / v, Hz.8 /.05.2 / / 17.1 [29.] ,2 2,0 PeADRP10JAQ 1.0 ( ) 1. (.215.) 1. (.8515.) 12.9 (5.71.1) /.10.0 /.8 N/A (5/8 ) 9.52 (/8 ) / v, Hz.81 /..20 / / [0.8] ,951 2, Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

35 1..1 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PeADRP Power Inverter Heat Pump ( Phase) Ceiling Concealed Ducted System PeADRP INDOOR UNITS PeADRP100JAQ PeADRP125JAQ PeADRP10JAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m 11.2 (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.91.2 / 5.5 A+ / A (5/8 ) 9.52 (/8 ) INDOOR PRICe 79 SYSTEM POWER INPUT (kw) PUHZZRP100YKA Phase 51 / v, Hz 2.0 / / /.20 [10.7] (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ) /.2.9 /.9 N/A (5/8 ) 9.52 (/8 ) PUHZZRP125YKA Phase 52 / v, Hz.8 /.05.2 / /.29 [12.] ( ) 1. (.215.) 1. (.8515.) 12. (5.71.1) /.10.0 /.7 N/A (5/8 ) 9.52 (/8 ) PUHZZRP10YKA Phase 52 / v, Hz.81 /..20 / / 7.0 [15.8] OUTDOOR PRICe 1,577 SYSTeM PRICe 2,70 1,7 2,5 2,110 2,981 Phase Note: Indoor price includes separate PAR2MAA wired remote controller.

36 PeADRP Standard Inverter Heat Pump ( Phase) Ceiling Concealed Ducted System PeADRP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PeADRP5JAQ PeADRPJAQ PeADRP0JAQ PeADRP71JAQ PeADRP100JAQ.1 (1.75.0). (1..9).9 (1.5.25).1 ( ) /.2.0 / 5.5 A+ / A (/8 ).5 (1/ ) (1.77.2).9 (2.5.) 5.02 (1.5.12).51 ( ) /.1.2 / 5. A+ / A (1/2 ).5 (1/ ) (2.58.0) 5.7 (2..) 5.95 (2.1.80) 5.2 ( ) 0.8. /.1.0 / 5. A+ / A (5/8 ).5 (1/ ) (2.10.2) 7.1 (2.88.1).80 ( ).5 ( ) /.1.9 / 5.8 A / A (5/8 ) 9.52 (/8 ) (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /. A / B (5/8 ) 9.52 (/8 ) INDOOR PRICe PeADRP125JAQ 1.0 (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ) / /.5 N/A (5/8 ) 9.52 (/8 ) PeADRP10JAQ 1.0 ( ) 1. ( ) 1. (.2515.) 12.5 ( ) /.01.7 /.2 N/A (5/8 ) 9.52 (/8 ) SUZKA / PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) SUZKA5VA SUZKAVA SUZKA0VA SUZKA71VA PUHZP100VHA5 / v, Hz 1.11 / / / 5.10 [9.] / v, Hz 1.2 / / / 7.0 [1.] / v, Hz 1.9 / / / 8.0 [15.] / v, Hz 2.0 / / / 9.10 [18.1] / v, Hz.10 / / / [0.5] OUTDOOR PRICe ,118 SYSTeM PRICe 1,117 1,28 1, 1,8 1,911 Notes: All units charged to 7m (571), 0m (10010) pipe length. Indoor price includes separate PAR2MAA wired remote controller. PUHZP125VHA 55 / v, Hz.87 / / / 19. [0.7] ,2 2,059 PUHZP10VHA 5 / v, Hz. / / / 2.97 [2.28] ,9 2, Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

37 1..18 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PeADRP Standard Inverter Heat Pump ( Phase) Ceiling Concealed Ducted System PeADRP INDOOR UNITS PeADRP100JAQ PeADRP125JAQ PeADRP10JAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /. A / B (5/8 ) 9.52 (/8 ) INDOOR PRICe (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ) / /.5 N/A (5/8 ) 9.52 (/8 ) ( ) 1. ( ) 1. (.2515.) 12.5 ( ) /.01.7 /.2 N/A (5/8 ) 9.52 (/8 ) PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) PUHZP100YHA Phase 5 / v, Hz.10 / / /.8 [15.5] OUTDOOR PRICe 1,191 SYSTeM PRICe 1,98 PUHZP125YHA2 Phase 55 / v, Hz.87 / / / 8.58 [15.7] , 2,12 PUHZP10YHA2 Phase 5 / v, Hz. / / / [15.78] ,01 2,72 Phase Notes: All units charged to 0m (10010) pipe length. Indoor price includes separate PAR2MAA wired remote controller.

38 PeADRP Zubadan Inverter Heat Pump Ceiling Concealed Ducted System PeADRP INDOOR UNITS PeADRP100JAQ PeADRP100JAQ PeADRP125JAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores INDOOR PRICe 11.2 (.51.0) 10.0 (.911.) 11.1 (.51.85) 9.2 (.510.5) /.2.8 /.8 A / B (5/8 ) 9.52 (/8 ) (.51.0) 10.0 (.911.) 11.1 (.51.85) 9.2 (.510.5) /.2.8 /.8 A / B (5/8 ) 9.52 (/8 ) (5.01.0) 12.5 (5.51.0) 1.85 ( ) 11.5 ( ) /.21. /.8 A / B (5/8 ) 9.52 (/8 ) PUHZSHW OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m OUTDOOR PRICe SYSTeM PRICe PUHZSHW112VHA 52 / v, Hz.10 / / / [7.8] ,52,25 PUHZSHW112YHA Phase 52 / , Hz.10 / / / 5.7 [15.8] ,709,2 PUHZSHW10YHA Phase 52 / , Hz.88 /.87.5 / / 7.2 [15.8] ,155,971 Phase Note: Indoor price includes separate PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

39 1..20 Air Conditioning PeARP Power Inverter Heat Pump Large Capacity Ceiling Concealed Ducted System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PeARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) ENERGY LABEL Heating/ AIRFLOW (l/s) LoHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) (Pa) LoHi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE POWER INPUT (kw) Nominal / UK STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. Cores PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PeARP200GAQ Phase 22. ( ) 19.0 (9.022.) ( ) 17.5 (8.20.) / 2.9 B / C (1 1/8 ) 9.52 (/8 ) v, Hz 1.00 / [2.] 5 PeARP2GAQ Phase 27.0 ( ) 22.0 ( ) ( ) ( ) / 2.5 C / D (1 1/8 ) 12.7 (1/2 ) v, Hz 1.18 / [2.8] 5 PeARP00GAQ Phase.8 (18.0.0) 8.0 (18.0.8) 8.1 (15.2.5).95 ( ) /.05 B / C (1 1/8 ) (/8 ) v, Hz 1.55 / [.] 10 5 PeARP0GAQ Phase 5.0 (25.0.0).0 (22.5.0) 5.9 ( ) 0.5 ( ) / 2.57 D / E (1 1/8 ) (1/2 ) v, Hz 2.8 / [.5] 10 5 INDOOR PRICe 1,227 1,99 2,08 2,55 PUHZZRP200YKA2 Phase 2 / v, Hz.9 /. 5.8 / / 8.9 [19] PUHZZRP2YKA2 Phase 2 / v, Hz 8.9 / / / 11.2 [21] PUHZZRP200YKA2 2 Phase 2 / v, Hz 1. / / / 8.9 [19] PUHZZRP2YKA2 2 Phase 2 / v, Hz 18. / / / 11.2 [21] OUTDOOR PRICe,075,275,1,5 SYSTeM PRICe,02,7 8,218 9,005 Phase Note: Indoor price includes separate PAR2MAA wired remote controller.

40 PeARP Standard Inverter Heat Pump Large Capacity Ceiling Concealed Ducted System PeARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) ENERGY LABEL Heating/ AIRFLOW (l/s) LoHi PIPE SIZE mm (in) Gas Liquid EXTERNAL STATIC PRESSURE (Pa) SOUND PRESSURE LEvEL (dba) (Pa) LoHi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE POWER INPUT (kw) Nominal / UK STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. Cores PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER Heating/ INPUT (kw) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PeARP200GAQ Phase 22. ( ) 19.0 (9.022.) ( ) 17.5 (8.20.) / 2.8 D / D (1 1/8 ) 9.52 (/8 ) v, Hz 1.00 / [2.] 5 PeARP2GAQ Phase 27.0 ( ) 22.0 ( ) ( ) ( ) / 2.5 D / D (1 1/8 ) 12.7 (1/2 ) v, Hz 1.18 / [2.8] 5 PeARP00GAQ Phase.8 (19.0.0) 8.0 (18.0.8) 8.1 ( ).95 ( ) / 2.9 D / D (1 1/8 ) (/8 ) v, Hz 1.55 / [.] 10 5 PeARP0GAQ Phase 5.0 (25.0.0).0 (22.5.0) 5.9 ( ) 0.5 ( ) / 2. D / E (1 1/8 ) (1/2 ) v, Hz 2.8 / [.5] 10 5 INDOOR PRICe 1,227 1,99 2,08 2,55 PUHZP200YKA2 Phase 0 / v, Hz 7. / / / 9.7 [19] PUHZP2YKA2 Phase 2 / v, Hz 8.7 / / / 11.0 [21] PUHZP200YKA2 2 Phase 0 / v, Hz 1.27 / / / 9.7 [19] per outdoor PUHZP2YKA2 2 Phase 2 / v, Hz 17.2 / / / 11.0 [21] per outdoor OUTDOOR PRICe 2,07 2,,81 5,28 SYSTeM PRICe,,02,882 7,71 Phase Note: Indoor price includes separate PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

41 1..22 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PCARP Power Inverter Heat Pump ( Phase) Ceiling Suspended System PCARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PCARPKAQ PCARP0KAQ PCARP71KAQ PCARP100KAQ PCARP125KAQ 7.0 (2.88.2).0 (2.7.7) 5.95 (2..95) 5.5 (2.5.15) /.7. /.2 A+ / A (5/8 ) / 9.52 (/8 ) (.510.2) 7.1 (.8.1).8 (.08.5).55 (.057.5) 0.7. /.90. /. A+ / A (5/8 ) / 9.52 (/8 ) (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.90.9 /.0 A / A (5/8 ) / 9.52 (/8 ) (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ) /.1.2 / 5.2 N/A (5/8 ) / 9.52 (/8 ) INDOOR PRICe SYSTEM POWER INPUT (kw) 5.5 (2.5.) 5.0 (2.5.).7 (2.155.). ( ) /.7.2 /.0 A+ / A (1/2 ) /.5 (1/ ) PUHZZRPVKA2 PUHZZRP0VHA2 PUHZZRP71VHA2 PUHZZRP100VKA PUHZZRP125VKA / v, Hz 1.5 / / /.5 [1.] / v, Hz 1.9 / / / 8.07 [19.] / v, Hz 2.20 / / / 7.78 [19.] / v, Hz.0 / / / [27.2] / v, Hz.80 / / / 17.2 [27.] OUTDOOR PRICe 1,082 1,179 1,229 1,58 1,2 SYSTeM PRICe 1,789 1,918 2,018 2,5 2,52 Note: Indoor price includes separate PAR2MAA wired remote controller. PCARP10KAQ 1.0 ( ) 1. (.215.0) 1. (.8515.) 12.9 (5.71.8) /.9. / 5. N/A (5/8 ) / 9.52 (/8 ) PUHZZRP10VKA 52 / v, Hz.57 /.95.8 / / [28.9] ,951 2,9

42 PCARP Power Inverter Heat Pump ( Phase) Ceiling Suspended System PCARP INDOOR UNITS PCARP100KAQ PCARP125KAQ PCARP10KAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores 11.2 (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) /.90.9 / 5.9 A / A (5/8 ) / 9.52 (/8 ) (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11.5 ( ) /.1.2 / 5.2 N/A (5/8 ) / 9.52 (/8 ) INDOOR PRICe ( ) 1. (.215.0) 1. (.8515.) 12. (5.71.8) /.9. / 5.2 N/A (5/8 ) / 9.52 (/8 ) PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PUHZZRP100YKA Phase 51 / v, Hz.0 / / /.0 [8.7] PUHZZRP125YKA Phase 52 / v, Hz.80 / / /.0 [10.] PUHZZRP10YKA Phase 52 / v, Hz.57 /.95.8 / / 7.51 [1.9] OUTDOOR PRICe 1,577 1,7 SYSTeM PRICe 2,72 2,8 2,110,092 Phase Note: Price includes separate PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

43 1..2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PCARP Standard Inverter Heat Pump ( Phase) Ceiling Suspended System PCARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PCARPKAQ PCARP0KAQ PCARP71KAQ PCARP100KAQ PCARP125KAQ 5.5 (1.7.) 5.0 (2.5.).2 (1.5.5).9 ( ) /.2.0 / 5.7 A+ / A (1/2 ) /.5 (1/ ) (2.58.0) 5.7 (2..) 5.8 (2.1.72) 5.58 ( ) /.1.0 /.0 A+ / A (5/8 ) /.5 (1/ ) (2.10.2) 7.1 (2.88.1). ( ).95 (2.77.9) /.1.0 /.0 A+ / A (5/8 ) / 9.52 (/8 ) (.512.5) 9. (.911.2) 9. ( ) 9.21 ( ) /.00.8 / 5.1 A / A (5/8 ) / 9.52 (/8 ) (5.01.0) 12. (5.51.0) 11.7 (.21.) ( ) /.01.7 /.5 N/A (5/8 ) / 9.52 (/8 ) INDOOR PRICe PCARP10KAQ 1.0 ( ) 1. ( ) 1. ( ) 1.2 (5.91.9) / /.2 N/A (5/8 ) / 9.52 (/8 ) SUZKA / PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) SUZKAVA SUZKA0VA SUZKA71VA PUHZP100VHA5 PUHZP125VHA 52 / v, Hz 1.52 / / / 7.70 [12.] / v, Hz 1.91 / / / 8.0 [1.] / v, Hz 2.18 / / / 8.70 [1.5] / v, Hz.28 / / / 1. [28.7] / v, Hz.12 /.09. / / 18.1 [28.8] OUTDOOR PRICe ,118 1,2 SYSTeM PRICe 1,79 1,57 1,592 2,01 2,11 PUHZP10VHA 5 / v, Hz.9 /.8.9 / / 2.8 [0.] ,9 2,91 Notes: All units charged to 7m (571), 0m (10010) pipe length. Indoor price includes separate PAR2MAA wired remote controller. Duty/standby not available on SUZKA/0/71VA.

44 PCARP Standard Inverter Heat Pump ( Phase) Ceiling Suspended System PCARP INDOOR UNITS PCARP100KAQ PCARP125KAQ PCARP10KAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMi1Mi2Hi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMi1Mi2Hi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.00.8 / 5.1 A / A (5/8 ) / 9.52 (/8 ) (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ) /.01.7 /.5 N/A (5/8 ) / 9.52 (/8 ) INDOOR PRICe PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) PUHZP100YHA Phase 5 / v, Hz.28 / / / 5.5 [1.7] PUHZP125YHA2 Phase 55 / v, Hz.12 /.09. / /.9 [1.8] ( ) 1. ( ) 1. (.2515.) 12.5 ( ) / /.2 N/A (5/8 ) / 9.52 (/8 ) PUHZP10YHA2 Phase 5 / v, Hz.9 /.8.9 / / 8.82 [1.9] OUTDOOR PRICe 1,191 1, SYSTeM PRICe 2,08 2,2 1,01 2,58 Phase Notes: All units charged to 7m (571), 0m (10010) pipe length. Indoor price includes separate PAR2MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

45 1..2 Air Conditioning PCARPHAQ Power Inverter Heat Pump Stainless Steel Ceiling Suspended System Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PCARPHAQ INDOOR UNITS PCARP71HAQ CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) 7. (.510.2) 7.1 (.8.1).5 (.08.5).55 (.057.5) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER ENERGY EFFICIENCY CLASS Heating/Cooling /.27.8 / 5. A / A+ AIRFLOW (l/s) LoHi 2817 PIPE SIZE mm (in) Gas/Liquid (5/8 ) / 9.52 (/8 ) SOUND PRESSURE LEvEL (dba) LoHi 8 SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) 1 INTERCONNECTING CABLE No. Cores INDOOR PRICe 1,228 PUHZZRP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m PUHZZRP71VHA2 8 / v, Hz 2.5 / / / 7.79 [19.] OUTDOOR PRICe 1,229 SYSTeM PRICe 2,57 Note: Indoor price includes separate PAR2MAA wired remote controller.

46 PSARP Power Inverter Heat Pump Floor Standing System PSARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) Unit / Panel ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores PSARP71KA PSARP100KA PSARP100KA PSARP125KA PSARP125KA 7. (.510.2) 7.1 (.8.1).5 (.08.5).55 (.057.5) /.7.0 /. A+ / A (5/8 ) / 9.52 (/8 ) (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) 0.7. /.80.0 / 5. A+ / A (5/8 ) / 9.52 (/8 ) (.51.0) 9.5 (.911.) 9.5 ( ) 9.2 (.510.5) 0.7. /.80.0 / 5.5 A+ / A (5/8 ) / 9.52 (/8 ) (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11. ( ) /.0.0 / 5.0 N/A (5/8 ) / 9.52 (/8 ) (5.01.0) 12.5 (5.51.0) 11.9 (.251.) 11. ( ) /.0.0 /.9 N/A (5/8 ) / 9.52 (/8 ) INDOOR PRICe ,00 1,00 1,089 1,089 PUHZZRP OUTDOOR UNITS PUHZZRP71VHA2 PUHZZRP100VKA PUHZZRP100YKA PUHZZRP125VKA PUHZZRP125YKA PUHZZRP10VKA PUHZZRP10YKA Phase Phase Phase SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m 8 / v, Hz 2.21 / / / 7.7 [19.] / v, Hz.08 / / / 11.2 [27.2] / v, Hz.08 / / /.55 [8.7] / v, Hz.2 /.09.5 / / 17.2 [27.2] / v, Hz.2 /.09.5 / /.57 [10.2] OUTDOOR PRICe 1,229 1,58 1,577 1,2 1,7 SYSTeM PRICe 2,072 2, 2,552 2,5 2,780 PSARP10KA 1.0 ( ) 1. (.215.0) 1. (.815.) 12. (5.71.8) /.0. / 5. N/A (5/8 ) / 9.52 (/8 ) / v, Hz.79 /.0.02 / / 19.1 [28.7] ,951,00 PSARP10KA 1.0 ( ) 1. (.215.0) 1. (.815.) 12. (5.71.8) /.0. / 5. N/A (5/8 ) / 9.52 (/8 ) / v, Hz.79 /.0.02 / / 7. [1.7] ,110,199 Phase Note: Indoor price includes built in PAR21MAA wired remote controller Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

47 1..28 Air Conditioning PSARP Standard Inverter Heat Pump Floor Standing System PSARP INDOOR UNITS CAPACITY (kw) Heating (nominal) Heating (UK) Cooling (UK) SHF (nominal & UK) COP / EER (nominal) SCOP / SEER (BS EN1825) ErP ENERGY EFFICIENCY CLASS Heating/Cooling AIRFLOW (l/s) LoMiHi PIPE SIZE mm (in) Gas/Liquid SOUND PRESSURE LEvEL (dba) LoMiHi SOUND POWER LEvEL (dba) DIMENSIONS (mm) Width Depth Height (Grille) WEIGHT (kg) ELECTRICAL SUPPLY FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. Cores INDOOR PRICe PUHZP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) OUTDOOR PRICe SYSTeM PRICe PSARP100KA PSARP100KA PSARP125KA PSARP125KA PSARP10KA 11.2 (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /. A / B (5/8 ) / 9.52 (/8 ) (.512.5) 9. (.911.2) 9.5 ( ) 8.5 (.510.) /.01.8 /. A / B (5/8 ) / 9.52 (/8 ) (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ) / /.5 N/A (5/8 ) / 9.52 (/8 ) (5.01.0) 12. (5.51.0) 11.9 (.251.) 11. ( ) / /.5 N/A (5/8 ) / 9.52 (/8 ) ,00 1,00 1,089 1,089 PUHZP100VHA5 PUHZP100YHA PUHZP125VHA PUHZP125YHA2 PUHZP10VHA PUHZP10YHA2 Phase Phase Phase 5 / v, Hz.28 / / / 1.9 [28.7] / v, Hz.28 / / / 5.71 [1.7] / v, Hz.98 /.8.19 / / [28.7] / v, Hz.98 /.8.19 / /.91 [1.7] ,118 1,191 1,2 1, 1,9 2,09 2,1 2,27 2,7 2,598 Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges 1.0 ( ) 1. ( ) 1. (.2515.) 12.5 ( ) / 2.1. /.2 N/A (5/8 ) / 9.52 (/8 ) / v, Hz 5.9 / / / 2.21 [0.2] PSARP10KA 1.0 ( ) 1. ( ) 1. (.2515.) 12.5 ( ) / 2.1. /.2 N/A (5/8 ) / 9.52 (/8 ) / v, Hz 5.9 / / / 8.5 [1.7] ,01 2,90 Phase Notes: Indoor price includes built in PAR21MAA wired remote controller. All units charged to 0m (10010) pipe length.

48 HP DXe Heat Pump Air Curtain HP DXe ReCeSSeD CAPACITY (kw) Heating (nominal) AIRFLOW MAX (l/s) SOUND PRESSURE LEvEL AT m (dba) LoMi1Hi WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY* 1 PHASE* 1 RUNNING CURRENT (A)* 1 MAINS CABLE No. Cores* 1 UNIFORMITY AT OUTLET (%)* 2 MAX MOUNTING HEIGHT (m) PRICe HP DXe FRee STANDING CAPACITY (kw) Heating (nominal) AIRFLOW MAX (l/s) SOUND PRESSURE LEvEL AT m (dba) LoMi1Hi WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY* 1 PHASE* 1 RUNNING CURRENT (A)* 1 MAINS CABLE No. Cores* 1 UNIFORMITY AT OUTLET (%)* 2 MAX MOUNTING HEIGHT (m) PRICe PRICe HeAT PUMP OUTDOOR UNITS SOUND PRESSURE LEvEL (dba) Heating/Cooling SOUND POWER LEvEL (dba) Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) 0m HP1000R DXe HP10R DXe HP10R DXe HP2000R DXe HP2000R DXe v, Hz v, Hz v, Hz v, Hz ,2 2,958 2,958,55,55,55 HP1000 DXe HP10 DXe HP10 DXe HP2000 DXe HP2000 DXe v, Hz v, Hz v, Hz v, Hz HP2000R DXe v, Hz HP2000 DXe v, Hz ,11 2,728 2,728,157,157,157 PUHZZRP10VKA PUHZZRP71VHA2 PUHZZRP125VKA PUHZZRP125YKA Phase 8 / v, Hz Core / v, Hz Core / v, Hz Core v, Hz v, Hz / v, Hz Core PUHZZRP10YKA Phase 52 / v, Hz Core PUHZZRP200YKA2 Phase 2 / v, Hz Core OUTDOOR PRICe 1,229 1,2 1,7 1,951 2,110,075 Phase Notes: *1 For indoor units with electric heaters enabled, 8015V ph power supply (7.A HP1000, 12.1A HP10, 1.A HP2000). *2 Tested to ISO Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

49 1..0 Air Conditioning PACIF01Be Air Handling Unit Controller Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PACIF01Be SIZe 5 SIZe SIZe 0 SIZe 71 SIZe 100 SIZe 125 SIZe 10 SIZe 200 SIZe 2 CAPACITY (kw) Heating (nominal) COMPATIBLE O.U PUHZZRP PUHZP PUHZSHW PIPE SIZE mm (in) PUHZZRP/P Gas Liquid PUHZSHW Gas Liquid HEAT EXCHANGER (cm ) Ma Volume >0m 20m 10m Min Volume DIMENSIONS (mm) Width Depth Height WEIGHT (No Accessories) (kg) PRICe.1. PUHZZRP5vKA2 N/A N/A 12.7 (1/2 ).5 (1/ ) kg PUHZZRPvKA2 N/A N/A 12.7 (1/2 ).5 (1/ ) kg PUHZZRP0vHA2 N/A N/A (5/8 ) 9.52 (/8 ) kg PUHZZRP71vHA2 N/A PUHZSHW80vHA (5/8 ) 9.52 (/8 ) (5/8 ) 9.52 (/8 ) kg PUHZZRP100vKA/YKA N/A PUHZSHW112vHA/YHA (5/8 ) 9.52 (/8 ) (5/8 ) 9.52 (/8 ) kg PUHZZRP125vKA/YKA N/A PUHZSHW10YHA (5/8 ) 9.52 (/8 ) (5/8 ) 9.52 (/8 ) kg PUHZZRP10vKA/YKA N/A N/A (5/8 ) 9.52 (/8 ) kg PUHZZRP200YKA2 PUHZP200YKA2 PUHZSHW20YKA (1 1/8 ) 9.52 (/8 ) (1 1/8 ) 12.7 (1/2 ) kg PUHZZRP2YKA2 PUHZP2YKA2 N/A (1 1/8 ) 12.7 (1/2 ) kg Notes: One air handling unit controller is required per air handling unit. Cooling: Indoor 27ºC DB/19ºC WB, Outdoor 5ºC DB/2ºC WB. Heating: Indoor 20ºC DB, Outdoor 7ºC DB/ºC WB.

50 Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TWIN SYSTeMS (Including pipe kit) (2) PLAZP5EA / (1) PUHZZRP71vHA2 (2) PLAZPEA / (1) PUHZZRP100vKA (2) PLAZP0EA / (1) PUHZZRP125vKA (2) PLAZP71EA / (1) PUHZZRP10vKA (2) PLAZPEA / (1) PUHZZRP100YKA (2) PLAZP0EA / (1) PUHZZRP125YKA (2) PLAZP71EA / (1) PUHZZRP10YKA (2) PLAZP100EA / (1) PUHZZRP200YKA2 (2) PLAZP125EA / (1) PUHZZRP2YKA2 (2) SLZKF5vA2 / (1) PUHZZRP71vHA2 (2) SLZKFvA2 / (1) PUHZZRP100vKA (2) SLZKF0vA2 / (1) PUHZZRP125vKA (2) SLZKFvA2 / (1) PUHZZRP100YKA (2) SLZKF0vA2 / (1) PUHZZRP125YKA DeSCRIPTION Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase Power Inverter Cassette, Twin System, Phase PRICe 2,7 2,71 2,9,91 2,85,090,,81 5,070 2,277 2,71 2,90 2,85,0 (2) PLARPEA / (1) PUHZP100vHA5 (2) PLARP0EA / (1) PUHZP125vHA (2) PLARP71EA / (1) PUHZP10vHA (2) PLARPEA / (1) PUHZP100YHA (2) PLARP0EA / (1) PUHZP125YHA2 (2) PLARP71EA / (1) PUHZP10YHA2 (2) PLARP100EA / (1) PUHZP200YKA2 (2) PLARP125EA / (1) PUHZP2YKA2 Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase Standard Inverter Cassette, Twin System, Phase 2,58 2,5 2,99 2,1 2,,085,0,2 (2) PLAZPEA / (1) PUHZSHW112vHA (2) PLAZPEA / (1) PUHZSHW112YHA (2) PLAZP0EA / (1) PUHZSHW10YHA Zubadan Inverter Cassette, Twin System, Phase Zubadan Inverter Cassette, Twin System, Phase Zubadan Inverter Cassette, Twin System, Phase,790,97, Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

51 1..2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TWIN SYSTeMS (Including pipe kit) (2) PKARP5HAL / (1) PUHZZRP71vHA2 (2) PKARPHAL / (1) PUHZZRP100vKA (2) PKARP0KAL / (1) PUHZZRP125vKA (2) PKARP71KAL / (1) PUHZZRP10vKA (2) PKARPHAL / (1) PUHZZRP100YKA (2) PKARP0KAL / (1) PUHZZRP125YKA (2) PKARP71KAL / (1) PUHZZRP10YKA (2) PKARP100KAL / (1) PUHZZRP200YKA2 (2) PKARPHAL / (1) PUHZP100vHA5 (2) PKARP0KAL / (1) PUHZP125vHA (2) PKARP71KAL / (1) PUHZP10vHA (2) PKARPHAL / (1) PUHZP100YHA (2) PKARP0KAL / (1) PUHZP125YHA2 (2) PKARP71KAL / (1) PUHZP10YHA2 (2) PKARP100KAL / (1) PUHZP200YKA2 (2) PKARPHAL / (1) PUHZSHW112vHA (2) PKARPHAL / (1) PUHZSHW112YHA (2) PEADRP5JAQ / (1) PUHZZRP71vHA2 (2) PEADRPJAQ / (1) PUHZZRP100vKA (2) PEADRP0JAQ / (1) PUHZZRP125vKA (2) PEADRP71JAQ / (1) PUHZZRP10vKA (2) PEADRPJAQ / (1) PUHZZRP100YKA (2) PEADRP0JAQ / (1) PUHZZRP125YKA (2) PEADRP71JAQ / (1) PUHZZRP10YKA (2) PEADRP100JAQ / (1) PUHZZRP200YKA2 (2) PEADRP125JAQ / (1) PUHZZRP2YKA2 DeSCRIPTION Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Power Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Standard Inverter Wall Mounted, Twin System, Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Concealed Ducted, Twin System, Phase PRICe 2,292 2,5 2,871,282 2,78 2,997,1,0 2,25 2,90 2,80 2,98 2,59 2,92,95,79,91 2,259 2,0 2,878,51 2,759,00,510,78,92

52 Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TWIN SYSTeMS (Including pipe kit) (2) PEADRPJAQ / (1) PUHZP100vHA5 (2) PEADRP0JAQ / (1) PUHZP125vHA (2) PEADRP71JAQ / (1) PUHZP10vHA (2) PEADRPJAQ / (1) PUHZP100YHA (2) PEADRP0JAQ / (1) PUHZP125YHA2 (2) PEADRP71JAQ / (1) PUHZP10YHA2 (2) PEADRP100JAQ / (1) PUHZP200YKA2 (2) PEADRP125JAQ / (1) PUHZP2YKA2 (2) PEADRPJAQ / (1) PUHZSHW112vHA (2) PEADRPJAQ / (1) PUHZSHW112YHA (2) PEADRP0JAQ / (1) PUHZSHW10YHA (2) PCARPKAQ / (1) PUHZZRP100vKA (2) PCARP0KAQ / (1) PUHZZRP125vKA (2) PCARP71KAQ / (1) PUHZZRP10vKA (2) PCARPKAQ / (1) PUHZZRP100YKA (2) PCARP0KAQ / (1) PUHZZRP125YKA (2) PCARP71KAQ / (1) PUHZZRP10YKA (2) PCARP100KAQ / (1) PUHZZRP200YKA2 (2) PCARP125KAQ / (1) PUHZZRP2YKA2 (2) PCARPKAQ / (1) PUHZP100vHA5 (2) PCARP0KAQ / (1) PUHZP125vHA (2) PCARP71KAQ / (1) PUHZP10vHA (2) PCARPKAQ / (1) PUHZP100YHA (2) PCARP0KAQ / (1) PUHZP125YHA2 (2) PCARP71KAQ / (1) PUHZP10YHA2 (2) PCARP100KAQ / (1) PUHZP200YKA2 (2) PCARP125KAQ / (1) PUHZP2YKA2 DeSCRIPTION Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Power Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase Standard Inverter Ceiling Suspended, Twin System, Phase PRICe 2,00 2,97 2,909 2,7 2,00,001,010,292,71,891,09 2,82,092,519 2,981,218,78,882 5,128 2,522 2,711,077 2,595 2,81,19,21,9 1.. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

53 1.. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TWIN SYSTeMS (Including pipe kit) (2) PCARP71HAQ / (1) PUHZZRP10vKA (2) PCARP71HAQ / (1) PUHZZRP10YKA (2) PSARP71GA / (1) PUHZZRP10vKA (2) PSARP71GA / (1) PUHZZRP10YKA (2) PSARP100GA / (1) PUHZZRP200YKA2 (2) PSARP125GA / (1) PUHZZRP2YKA2 (2) PSARP71GA / (1) PUHZP10vHA (2) PSARP71GA / (1) PUHZP10YHA2 (2) PSARP100GA / (1) PUHZP200YKA2 (2) PSARP125GA / (1) PUHZP2YKA2 DeSCRIPTION Power Inverter Stainless Steel Ceiling Suspended, Twin System, Phase Power Inverter Stainless Steel Ceiling Suspended, Twin System, Phase Power Inverter Floor Mounted, Twin System, Phase Power Inverter Floor Mounted, Twin System, Phase Power Inverter Floor Mounted, Twin System, Phase Power Inverter Floor Mounted, Twin System, Phase Standard Inverter Floor Mounted, Twin System, Phase Standard Inverter Floor Mounted, Twin System, Phase Standard Inverter Floor Mounted, Twin System, Phase Standard Inverter Floor Mounted, Twin System, Phase PRICe,97,55,777,9 5,192 5,2,5,27,52,870 TRIPLe SYSTeMS (Including pipe kit) () PLAZPEA / (1) PUHZZRP10vKA () PLAZPEA / (1) PUHZZRP10YKA () PLAZP0EA / (1) PUHZZRP200YKA2 () PLAZP71EA / (1) PUHZZRP2YKA2 () SLZKF5vA2 / (1) PUHZZRP100vKA () SLZKFvA2 / (1) PUHZZRP125vKA () SLZKFvA2 / (1) PUHZZRP10vKA () SLZKF5vA2 / (1) PUHZZRP100YKA () SLZKFvA2 / (1) PUHZZRP125YKA () SLZKFvA2 / (1) PUHZZRP10YKA () PLARPEA / (1) PUHZP10vHA () PLARPEA / (1) PUHZP10YHA2 () PLARP0EA / (1) PUHZP200YKA2 () PLARP71EA / (1) PUHZP2YKA2 DeSCRIPTION Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Power Inverter Cassette, Triple System, Phase Standard Inverter Cassette, Triple System, Phase Standard Inverter Cassette, Triple System, Phase Standard Inverter Cassette, Triple System, Phase Standard Inverter Cassette, Triple System, Phase PRICe,878,07 5,125 5,25,070,551,878,189,77,07,09,1,27,909

54 Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TRIPLe SYSTeMS (Including pipe kit) () PKARPHAL / (1) PUHZZRP10vKA () PKARPHAL / (1) PUHZZRP10YKA () PKARP0KAL / (1) PUHZZRP200YKA2 () PKARP71KAL / (1) PUHZZRP2YKA2 () PKARPHAL / (1) PUHZP10vHA () PKARPHAL / (1) PUHZP10YHA2 () PKARP0KAL / (1) PUHZP200YKA2 () PKARP71KAL / (1) PUHZP2YKA2 () PEADRPJAQ / (1) PUHZZRP10vKA () PEADRPJAQ / (1) PUHZZRP10YKA () PEADRP0JAQ / (1) PUHZZRP200YKA2 () PEADRP71JAQ / (1) PUHZZRP2YKA2 () PEADRPJAQ / (1) PUHZP10vHA () PEADRPJAQ / (1) PUHZP10YHA2 () PEADRP0JAQ / (1) PUHZP200YKA2 () PEADRP71JAQ / (1) PUHZP2YKA2 () PCARPKAQ / (1) PUHZZRP10vKA () PCARPKAQ / (1) PUHZZRP10YKA () PCARP0KAQ / (1) PUHZZRP200YKA2 () PCARP71KAQ / (1) PUHZZRP2YKA2 () PCARPKAQ / (1) PUHZP10vHA () PCARPKAQ / (1) PUHZP10YHA2 () PCARP0KAQ / (1) PUHZP200YKA2 () PCARP71KAQ / (1) PUHZP2YKA2 DeSCRIPTION Power Inverter Wall Mounted, Triple System, Phase Power Inverter Wall Mounted, Triple System, Phase Power Inverter Wall Mounted, Triple System, Phase Power Inverter Wall Mounted, Triple System, Phase Standard Inverter Wall Mounted, Triple System, Phase Standard Inverter Wall Mounted, Triple System, Phase Standard Inverter Wall Mounted, Triple System, Phase Standard Inverter Wall Mounted, Triple System, Phase Power Ceiling Concealed Ducted, Triple System, Phase Power Ceiling Concealed Ducted, Triple System, Phase Power Ceiling Concealed Ducted, Triple System, Phase Power Ceiling Concealed Ducted, Triple System, Phase Standard Ceiling Concealed Ducted, Triple System, Phase Standard Ceiling Concealed Ducted, Triple System, Phase Standard Ceiling Concealed Ducted, Triple System, Phase Standard Ceiling Concealed Ducted, Triple System, Phase Power Inverter Ceiling Suspended, Triple System, Phase Power Inverter Ceiling Suspended, Triple System, Phase Power Inverter Ceiling Suspended, Triple System, Phase Power Inverter Ceiling Suspended, Triple System, Phase Standard Inverter Ceiling Suspended, Triple System, Phase Standard Inverter Ceiling Suspended, Triple System, Phase Standard Inverter Ceiling Suspended, Triple System, Phase Standard Inverter Ceiling Suspended, Triple System, Phase PRICe,89,998 5,02 5,9,97,89,55,717,7,92,99 5,15,22,1,28,78,097,25 5,17 5,7,55,77,9 5, Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

55 1.. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Mr Slim Twin, Triple, Quad Combinations (Prices include pipe kits, grilles if required and one remote controller per combination.) TRIPLe SYSTeMS (Including pipe kit) () PCARP71HAQ / (1) PUHZZRP2YKA2 () PCARP71HAQ / (1) PUHZP2YKA2 () PSARP71GA / (1) PUHZZRP2YKA2 () PSARP71GA / (1) PUHZP2YKA2 DeSCRIPTION Power Inverter Stainless Steel Ceiling Suspended, Triple System, Phase Standard Inverter Stainless Steel Ceiling Suspended, Triple System, Phase Power Inverter Floor Mounted, Triple System, Phase Standard Inverter Floor Mounted, Triple System, Phase PRICe,98,52 5,979 5,7 QUAD SYSTeMS (Including pipe kit) () PLAZPEA / (1) PUHZZRP200YKA2 () PLAZP0EA / (1) PUHZZRP2YKA2 () SLZKF5vA2 / (1) PUHZZRP125vKA () SLZKF5vA2 / (1) PUHZZRP10vKA () SLZKF5vA2 / (1) PUHZZRP125YKA () SLZKF5vA2 / (1) PUHZZRP10YKA () PLARPEA / (1) PUHZP200YKA2 () PLARP0EA / (1) PUHZP2YKA2 () PKARPHAL / (1) PUHZZRP200YKA2 () PKARP0KAL / (1) PUHZZRP2YKA2 () PKARPHAL / (1) PUHZP200YKA2 () PKARP0KAL / (1) PUHZP2YKA2 () PEADRPJAQ / (1) PUHZZRP200YKA2 () PEADRP0JAQ / (1) PUHZZRP2YKA2 () PEADRPJAQ / (1) PUHZP200YKA2 () PEADRP0JAQ / (1) PUHZP2YKA2 () PCARPKAQ / (1) PUHZZRP200YKA2 () PCARP0KAQ / (1) PUHZZRP2YKA2 () PCARPKAQ / (1) PUHZP200YKA2 () PCARP0KAQ / (1) PUHZP2YKA2 DeSCRIPTION Power Inverter Cassette, Quadruple System, phase Power Inverter Cassette, Quadruple System, phase Power Inverter Cassette, Quadruple System, phase Power Inverter Cassette, Quadruple System, phase Power Inverter Cassette, Quadruple System, phase Power Inverter Cassette, Quadruple System, phase Standard Inverter Cassette, Quadruple System, phase Standard Inverter Cassette, Quadruple System, phase Power Inverter Wall Mounted, Quadruple System, Phase Power Inverter Wall Mounted, Quadruple System, Phase Standard Inverter Wall Mounted, Quadruple System, Phase Standard Inverter Wall Mounted, Quadruple System, Phase Power Inverter Ceiling Concealed Ducted, Quadruple System, Phase Power Inverter Ceiling Concealed Ducted, Quadruple System, Phase Standard Inverter Ceiling Concealed Ducted, Quadruple System, Phase Standard Inverter Ceiling Concealed Ducted, Quadruple System, Phase Power Inverter Ceiling Suspended, Quadruple System, Phase Power Inverter Ceiling Suspended, Quadruple System, Phase Standard Inverter Ceiling Suspended, Quadruple System, Phase Standard Inverter Ceiling Suspended, Quadruple System, Phase PRICe 5,70,070,85,12,91,21 5,002 5,98 5,79 5,959 5,011 5,27 5,55 5,898,88 5,2 5,998,2 5,0 5,9

56 Mr Slim Accessories / Optional etras PIPe KITS MSDDTR MSDDWR MSDT111R MSDF1111R Indoor Units DeSCRIPTION Multi distribution pipe twin units : sizes 71/100/125/10 Multi distribution pipe twin units : sizes 200/2 Multi distribution pipe triple units :: sizes 10/200/2 Multi distribution pipe quadruple units 25:25:25:25 sizes 200/2 PRICe WALL MOUNTeD UNITS S S DeSCRIPTION Terminal block CN22 connector PRICe 2 1 WAY BLOW CASSeTTe UNITS SLP2FA SLP2FAE PLPEA PLPEAE PLPEAJ (coming March 2017) PACSE1MEE PARSE9FAE PACSJ7SPE PACSJ1TME PACSJ9HRE PLPBA PLPBALM PLPBAJ PACSH5TM PACSA1ME PARSA9FA PARSL97A PACSH515P DeSCRIPTION Grille for SLZKF2VA2 D isee sensor grille for SLZKF2VA2 Grille for PLAZP/RP510EA D isee sensor grille for PLAZP/RP510EA Self elevating grille for PLAZP/RP510EA Corner panel with isee sensor for PLAZP/RP510EA Corner panel with signal receiver for PLAZP/RP510EA Shutter plate for PLAZP/RP510EA Multifunction casement for PLAZP/RP510EA Power supply kit for PLAZP/RP510EA Grille for PLASP Grille and infrared controller for PLASP Grille with filter lowering function for PLASP Multi function casement PLASP for fresh air 100mm knockout or to hold the high efficiency filter option Corner panel isee sensor for PLASP Infrared signal receiver for PLASP Infrared controller for PLASP Shutter Plate for PLASP PRICe Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

57 1..8 Air Conditioning Mr Slim Accessories / Optional etras Indoor Units Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges CeILING SUSPeNDeD UNITS PARSL9B PACSH8DM PACSH8DM PACSH85DM PACSG8KF PACSF81KC DeSCRIPTION Wireless remote controller and adaptor Optional drain lift pump for PCARPKAQ Optional drain lift pump for PCARP7110KAQ Optional drain lift pump for PCARP0KAQ Oil mist filter for PCARP71HAQ (12 pack) Decoration covers (front cover & suspending bracket) for PCARP71HAQ PRICe Outdoor Units / System Control Units / Power Supply Terminal Kits OUTDOOR UNITS PACSJ08DS PACSG1DS PACSJ07SG PACSG59SG PACSH9SG PACSJ0SG PACSHAG PACSH95AG MAC889SG MAC88SG PACSJ71FME DeSCRIPTION Drain socket set for PUHZZRP5 Drain socket set for PUHZZRP02 / PUHZ(S)P10010 / PUHZP2002 / PUHZSHW11210 Air outlet guide for PUHZZRP5 Air outlet guide for PUHZZRP071 / PUHZ(S)P10010 / PUHZSHW11210 Air outlet guide for PUHZZRP1002 / PUHZP2002 Air protect guide (allows cooling at 15ºC) for PUHZZRP5 Air protect guide (allows cooling at 15ºC) for PUHZZRP071 / PUHZP10010 / PUHZSHW11210 Air protect guide (allows cooling at 15ºC) for PUHZZRP1002 / PUHZP2002 Air outlet guide for SUZKA5VA Air outlet guide for SUZKA71VA 0Pa outdoor fan motor for PUHZZRP10010VKA PRICe SYSTeM CONTROL UNITS PACSA89TA PACSA88HA PACSF0RM MACIF MAC97IF PACSE1TS DeSCRIPTION Remote on/off adaptor Run/fault adapter Run/fault interface Interface for group control, run fault and connection to MNET System for SEZKD2571VAQ Interface for group control and run/fault SEZKD2571VAQ Remote sensor PRICe

58 Mr Slim Accessories / Optional etras Outdoor Units / System Control Units / Power Supply Terminal Kits SYSTeM CONTROL UNITS MAC557IF PACSJ19MA PACSF8MA PACYT52CRA PAR2MAA MELCOBEMS MINI IO INTERFACE DeSCRIPTION MELCloud WiFi interface A/MNET adaptor for PUHZZRP5 A/MNET adaptor for PUHZZRP02 / PUHZP1002 / PUHZSHW Simplified remote controller Remote controller Modbus / BACnet Interface Input/output interface PRICe POWeR SUPPLY TeRMINAL KITS PACSJ9HR PACSG9HR PACSG9HR PACSG97HR DeSCRIPTION Power supply terminal kit for PLARP and PLAZP Power supply terminal kit for PKARP Power supply terminal kit for PCARP / PSARP Power supply terminal kit for PEADRP / PCARPHAQ PRICe Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

59 MultiSplits SplitSystem Air Conditioning

60

61 The Fleible & Efficient MultiSplit Range Ideal for shops and small commercial buildings that require air conditioning in more than one room, the Mitsubishi Electric MultiSplit systems combine fleibility and performance while lowering CO 2 emissions and running costs. Using R10A refrigerant and fleible enough to suit a number of applications, the range includes models that will run up to si indoor units per single outdoor unit, between 5. and 12.2kW. With vastly reduced power consumption, inverter technology and with increased pipe length and advanced controls, the MultiSplit range is etremely efficient and versatile, helping to make system application easier. A variety of indoor units can be connected to a single outdoor unit, these include cassettes, ducted, wall, floor or ceiling mounted. The range is one of the most efficient in the industry with energy efficiency class up to A++. Eample of a way MultiSplit System Operational Range Operation range Cooling Heating MXZ 10ºC to +ºC 15ºC to +2ºC Nominal Conditions: Cooling; indoor 27ºC DB, 19ºC WB; outdoor 5ºC DB, 2ºC WB. Nominal Conditions: Heating; indoor 20ºC DB; outdoor 7ºC DB, ºC WB. UK Conditions: Summer; indoor 21ºC DB, 15ºC WB; outdoor 27ºC DB. UK Conditions: Winter; indoor 21ºC DB; outdoor 0 C DB, 1ºC WB Air Conditioning MultiSplits

62 The Fleible & Efficient MultiSplit Range Contents MXZD/E MultiSplit Inverter Heat Pump MultiSplit Accessories / Optional Etras Air Conditioning MultiSplits

63 Any price shown is our commercial price list (CPL) pricing; e VAT 1.. Air Conditioning MultiSplits Price ecludes any special delivery charges MXZD/E Inverter Heat Pump (5.12.2kW) MultiSplit Units MULTISPLIT INDOOR UNITS WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE CEILING DUCTED MXZ2D5VA2 MXZE5VA MXZE72VA MXZE8VA MXZ5E102VA MXZD122VA MSZSF20VE / MSZSF/25/5VE MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MSZSF20VE / MSZSF/25/5/VE MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MSZSF20VE / MSZSF/25/5/VE / MSZGF0VE2 MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MSZSF20VE / MSZSF/25/5/VE / MSZGF0/71VE2 MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MSZSF20VE / MSZSF/25/5/VE / MSZGF0/71VE2 MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MSZSF20VE / MSZSF/25/5/VE / MSZGF0/71VE2 MSZFH25/5VE2 / MSZEF25/5/VEB/S/W MFZKJ25/5VE2 MFZKJ25/5/VE2 MFZKJ25/5/VE2 MFZKJ25/5/VE2 MFZKJ25/5/VE2 MFZKJ25/5/VE2 SEZKD25/5VAQ * SLZKF25/5VA2 SEZKD25/5/VAQ * PEADRPJAQ *1 SEZKD25/5//0VAQ * PEADRPJAQ *1 SEZKD25/5//0/71VAQ * PEADRP/0/71JAQ *1 SEZKD25/5//0/71VAQ * PEADRP/0/71JAQ*1 SEZKD25/5//0/71VAQ * PEADRP/0/71JAQ *1 SLZKF25/5/VA2 PLARPEA SLZKF25/5/VA2 PLARP/0EA SLZKF25/5/VA2 PLARP/0/71EA SLZKF25/5/VA2 PLARP/0/71EA SLZKF25/5/VA2 PLARP/0/71EA PCARPKAQ PCARP/0KAQ PCARP/0/71KAQ PCARP/0/71KAQ PCARP/0/71KAQ MXZD/E OUTDOOR UNITS NUMBER OF CONNECTABLE INDOOR UNITS CAPACITy (kw) Heating (nominal) Heating (UK) Cooling (UK) COP / EER (nominal) *2 SCOP / SEER (BSEN1825) ErP ENERGy EFFICIENCy CLASS Heating/Cooling MAX AIRFLOW (m /min) Heating/Cooling SOUND PRESSURE LEVEL (dba) Heating/Cooling SilHi SOUND POWER LEVEL (dba) Cooling DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLy PHASE POWER INPUT (kw) Heating/ Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) Heating/Cooling [MAX] INTERCONNECTING CABLE No. CORES TOTAL PIPE LENGTH (m) MAX PIPE LENGTH PER INDOOR UNIT (m) MAX HEIGHT DIFFERENCE (m) CHARGE R10A (kg) [Precharged Length] FUSE RATING (BS88) HRC (A) 2. (1.07.0) 5. (1.15.) 5. ( ) 5.2 ( ).7 /..2 / 7.1 A+ / A++. / / v, Hz 1.70 / / /.9 [12.2] Core (10 if OU higher than IU) 1.0 [20m] 15 OUTDOOR PRICE 85 1,01 1,527 1,855 2,07 Multi Split models with eight ports, 1 and 15.5 kw can now be found in Y Series (.58hp) City Multi section. MXZ2D5VA2 MXZE5VA MXZE72VA MXZE8VA MXZ5E102VA (2.9.0) 5. (2.9.8) 5.8 (2.17.7) 5. (2.87.7).0 /.00.0 /. A+ / A++.0 / / v, Hz 1.59 / / /.1 [18] Core (10 if OU higher than IU) 2.70 [0m] (.10.7) 7.1 (.78.8) 7.1 ( ) 7.0 (.78.72).77 /.20.9 / 5.7 A+ / A+.0 / / v, Hz 2.28 / / / 9.9 [18] Core (10 if OU higher than IU) 2.70 [0m] (.11.) 8. (.79.2) 7.8 (2.829.) 8.2 (.79.12).5 /.0.2 /. A+ / A++.9 / / v, Hz 2. / / / 12. [20.] Core (10 if OU higher than IU) 2.99 [20m] (.11.0) 10.2 (.911.0) 8.7 (.011.) 10.1 ( ).9 /.2.20 /. A+ / A++ 7. / / v, Hz 2. / / / 17.2 [21.] Core (10 if OU higher than IU) 2.99 [20m] 25 MXZD122VA (.51.5) 12.2 (.51.5) 11. ( ) 12.1 (.71.9).2 /. / N/A 77 / 57 / v, Hz.1 /..0 / / 1.1 [0] Core (10 if OU higher than IU).0 [0m] 2 2,705 Notes: *1 Combined ma running current of all indoors on system must not eceed A if PEADRP is used. *2 System COP / EER when connected to MSZEF indoor unit connections. * The SEZKD25VAQ cannot be used when the total indoor capacity is equal to the outdoor capacity i.e. when the capacity ratio is 1.

64 MultiSplit Accessories / Optional Etras OUTDOOR UNITS MAC889SG MAC85SG MAC857SG SYSTEM CONTROL UNITS PAR2MAA MACIF MAC97IF MAC557IF PACYT52CRA IO INTERFACE MELCOBEMS MINI DESCRIPTION Air outlet guides for MXZ2D5VA2 Air outlet guides for MXZE5VA, MXZE72VA, MXZE8VA, MXZ5E102VA Air outlet guides for MXZD122VA DESCRIPTION Remote controller Interface for group control, run fault and connection to MNET System Interface for Contact Terminal and PAR2MAA / PACyT52CRA Wired Remote Controller Interface for connection to WiFi MELCloud service Simplified wired remote controller Input/output interface Modbus/BACnet interface PRICE PRICE Any price shown is our commercial price list (CPL) pricing; e VAT 1..5 Air Conditioning MultiSplits Price ecludes any special delivery charges

65 City Multi Energy Efficient VRF Systems

66

67 The Energy Efficient City Multi VRF Range The City Multi range is Mitsubishi Electric s answer to large scale VRF (Variable Refrigerant Flow) applications. The technology of City Multi is second to none and offers ecellent seasonal energy efficiency, low running costs and reduced CO 2 emissions. Suitable for medium to large buildings that demand high performance with optimum efficiency, our City Multi VRF range can run numerous indoor units connected to one outdoor unit. VRF Systems Our City Multi VRF Systems offer both heat pump and heat recovery technology. Heat pump systems deliver cooling or heating to a space, whereas heat recovery systems can simultaneously provide cooling and heating at the same time via separate indoor units, moving energy around a building for maimum efficiency. The City Multi Y Series heat pump system offers a simple and fleible solution where there is a demand for a changeover capability between heating and cooling for all indoor units, helping to ensure a constant and comfortable indoor climate. The City Multi R2 heat recovery system can provide simultaneous heating and cooling through only two pipes rather than the conventional three which are traditionally used on heat recovery systems, typically reducing installation time and material costs. Recovered energy can not only be moved around rooms within a building but can also be upgraded to heat water for sanitary use. By transferring wasted heat in this way, substantial savings can be made on annual running costs and CO 2 emissions. With a range of over 80 indoor units of varying capacity including floor standing, ducted, ceiling cassettes, ceiling suspended and wall mounted types, up to indoor units can be connected to one City Multi outdoor unit Air Conditioning

68 The Energy Efficient City Multi VRF Range Contents Y Series (.58hp) Heat Pump, Outdoor Unit Y Series Standard (818hp) Heat Pump, Outdoor Unit Y Series Standard (200hp) Heat Pump, Outdoor Unit Y Series Standard (2hp) Heat Pump, Outdoor Unit Y Series Standard (8hp) Heat Pump, Outdoor Unit Y Series Standard (hp) Heat Pump, Outdoor Unit Y Series High COP (81hp) Heat Pump, Outdoor Unit Y Series High COP (12hp) Heat Pump, Outdoor Unit Y Series High COP (20hp) Heat Pump, Outdoor Unit Y Series High COP (2hp) Heat Pump, Outdoor Unit Y Series Replace Multi (822hp) Heat Pump, Outdoor Unit Y Series Replace Multi (2hp) Heat Pump, Outdoor Unit R2 Series Standard (818hp) Heat Recovery, Outdoor Unit R2 Series Standard (2028hp) Heat Recovery, Outdoor Unit R2 Series Standard (0hp) Heat Recovery, Outdoor Unit R2 Series High COP (820hp) Heat Recovery, Outdoor Unit R2 Series High COP (2228hp) Heat Recovery, Outdoor Unit R2 Series High COP (0hp) Heat Recovery, Outdoor Unit R2 Series Replace Multi (812hp) Heat Recovery, Outdoor Unit WY Series (820hp) Heat Pump, Water Cooled Condensing Unit WY Series (22hp) Heat Pump, Water Cooled Condensing Unit WR2 Series (820hp) Heat Recovery, Water Cooled Condensing Unit WR2 Series (22hp) Heat Recovery, Water Cooled Condensing Unit PFDPVME Heat Pump, Close Control System PLFYPVEME Way Blow Ceiling Cassette Indoor Unit PLFYPVFME 0000 Way Blow Ceiling Cassette Indoor Unit PEFYPVMS1E Ultra Thin Ceiling Concealed Ducted Indoor Unit PEFYPVMAE Ceiling Concealed Ducted Indoor Unit PEFYPVMH(S)E High Static Pressure Ceiling Concealed Ducted Indoor Unit PCFYPVKME Ceiling Suspended Indoor Unit PKFYPVBME/VHME/VKME Wall Mounted Indoor Unit PFFYPVLRME Floor Standing Concealed Indoor Unit PFFYPVLRMME Floor Standing Concealed Indoor Unit PFFYPVLEME Floor Standing Eposed Indoor Unit PFFYPVKME Floor Standing Eposed Indoor Unit PLFYWPVBME (HVRF) Way Blow Ceiling Cassette Indoor Unit PEFYWPVMS1E (HVRF) Ultra Thin Ceiling Concealed Ducted Indoor Unit PEFYWPVMAE (HVRF) Ceiling Concealed Ducted Indoor Unit PFFYWPVLRMME (HVRF) Floor Standing Concealed Ducted Indoor Unit GUFRD Lossnay Outdoor Air Processing Unit PWFYPVMEBU VRF Sanitary Water Heater VRF HP DXE Heat Pump Air Curtain PACLV11M LEV Kit Interface PACMKBC Branch Bo BC Controllers Refrigerant Detection Systems Accessories / Optional Etras Air Conditioning

69 1.5. Air Conditioning Y series (.58hp) Heat Pump Outdoor Unit Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUtdOOr Units CapaCiTy (kw) Heating (nominal) Heating (UK) Cooling (UK) power input (kw) Heating (nominal) Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) Ma no. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) pipe SiZE mm (in) SOUND pressure LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Gas Liquid Width Depth Height ELECTRiCaL SUppLy phase STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Heating / Cooling PUMYP112VKM PUMYP112YKM PUMYP125VKM PUMYP125YKM PUMYP10VKM PUMYP10YKM /.8.9 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz / 12.2 [29.5] 20~15 / 5~ /.8.9 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz /.7 [1.0] 20~15 / 5~ earth /.05.9 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz / [29.5] 20~15 / 5~ /.05.9 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz 5.00 / 5.55 [1.0] 20~15 / 5~ earth /..1 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz / [29.5] 20~15 / 5~ /..1 / % OU Capacity (5/8 ) 9.52 (/8 ) v, Hz 5.79 /.87 [1.0] 20~15 / 5~ earth PUMYP200YKM /.70.1 / % OU Capacity (/ ) 9.52 (/8 )* v, Hz / 9.05 [19.0] 20~15 / 5~ earth Note: * 12.7mm (1/2 ) if furthest length 0m PriCE 2,820 2,820,172,172,51,51,021

70 Y series standard (818hp) Heat Pump Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYP200YKBA1 PUHYP2YKBA1 PUHYP00YKBA1 PUHYPYKBA1 PUHYP00YKBA1 PUHYPYKBA / / % OU Capacity (7/8 ) 9.52 (/8 ) v, Hz 8 9. / 8. [1.1] 20~15.5 / 5~ earth / / % OU Capacity (7/8 ) 9.52 (/8 )** v, Hz / 11.0 [17.8] 20~15.5 / 5~ earth / / % OU Capacity (7/8 ) 9.52 (/8 )** v, Hz / 1.7 [22.1] 20~15.5 / 5~ earth / /. 0 10% OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz / 18.7 [28.2] 20~15.5 / 5~ earth /.2.5 /.0 10% OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz / 21.7 [2.7] 20~15.5 / 5~ earth /.8. / % OU Capacity (11/8 ) (5/8 ) v, Hz / 2.7 [7.8] 20~15.5 / 5~ earth PriCE,021 5,02,151 7,17 8,28 9,22 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. **12.7mm(1/2 ) if P2 furthest length 90m, P00 furthest length 0m Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

71 1.5. Air Conditioning Y series standard (200hp) Heat Pump Outdoor Unit Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYP0YKBA1 PUHYP5YsKBA1 PUHYP00YsKBA1 PUHYPYsKBA1 PUHYP700YsKBA1 PUHYP7YsKBA / /.8 10% OU Capacity (11/8 ) (5/8 ) v, Hz 8 / / 29. [.] 20~15.5 / 5~ earth / / % OU Capacity 210 / (11/8 ) (5/8 ) v, Hz 8 / / 2.7 [ ] 20~15.5 / 5~ / earth / /.9 10% OU Capacity 210 / (11/8 ) (5/8 ) v, Hz 8 / / 1.1[ ] 20~15.5 / 5~ / earth /.8.8 /.9 10% OU Capacity 210 / (11/8 ) (5/8 ) v, Hz 8 / 8. /. [ ] 20~15.5 / 5~ / earth / /.7 10% OU Capacity 210 / (1/8 ) (/ ) v, Hz 8 / 8.8 / 9.5 [ ] 20~15.5 / 5~ / earth / / % OU Capacity 210 / (1/8 ) (/ ) v, Hz 8 / / 2.5 [ ] 20~15.5 / 5~ / earth PriCE 10,12 11,21 12,28 1, 1,99 15, Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

72 Y series standard (2hp) Heat Pump Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYP800YsKBA1 PUHYP8YsKBA1 PUHYP900YsKBA /.2 5. / % OU Capacity 0 / (1/8 ) (/ ) v, Hz 8 / 8.2 /. [ ] 20~15.5 / 5~ / earth / /.01 10% OU Capacity 0 / (15/8 ) (/ ) v, Hz 8 / / 8. [ ] 20~15.5 / 5~ / earth / /.08 10% OU Capacity 0 / (15/8 ) (/ ) v, Hz 8 / /. [ ] 20~15.5 / 5~ / earth PriCE 1,99 17,55 18,99 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

73 1.5.8 Air Conditioning Y series standard (8hp) Heat Pump Outdoor Unit Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYP9YsKBA1 PUHYP1000YsKBA1 PUHYP10YsKBA1 PUHYP1100YsKBA / /.71 10% OU Capacity 210 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / / 8.5 [ ] 20~15.5 / 5~ / 1 25 / earth / /.7 10% OU Capacity 210 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / / 51. [ ] 20~15.5 / 5~ / 1 25 / earth /.7 5. /.5 10% OU Capacity 210 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / / 5.1 [ ] 20~15.5 / 5~ / 1 2 / earth / /.0 10% OU Capacity 210 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / / 1.9 [ ] 20~15.5 / 5~ / 1 2 / earth PriCE 19,52 20,72 21,787 22,812 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

74 Y series standard (hp) Heat Pump Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYP11YsKBA1 PUHYP1200YsKBA1 PUHYP12YsKBA /.2 5. /. 10% OU Capacity 0 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / 8.0 /.5 [ ] 20~15.5 / 5~ / 1 2 / earth /.08.5 / % OU Capacity 0 / 210 / (15/8 ) (/ ) v, Hz 8 / 8 / 8 5. / 70.7 [ ] 20~15.5 / 5~ / 1 0 / earth /.19.5 /. 10% OU Capacity 0 / 0 / (15/8 ) (/ ) v, Hz 8 / 8 / / 70.2 [ ] 20~15.5 / 5~ / 1 0 / earth PriCE 2,755 2,82 25,805 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

75 Air Conditioning Y series High COP (81hp) Heat Pump Outdoor Unit Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYEP200YLMA1 PUHYEP2YLMA1 PUHYEP00YLMA1 PUHYEPYLMA / / ~10% OU Capacity (7/8 ) 9.52 (/8 ) v, Hz / 8.0 [1.1] 20~15.5 / 5~ /.0.00 / ~10% OU Capacity (7/8 ) 9.52 (/8 )** v, Hz / 10. [18.1] 20~15.5 / 5~ / / ~10% OU Capacity (11/8 ) 9.52 (/8 )** v, Hz / 1.2 [21.] 20~15.5 / 5~ / / ~10% OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz / 18.0 [28.7] 20~15.5 / 5~ PriCE,598 5,77 7,21 8,17 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. **12.7mm(1/2 ) if furthest length 0m.

76 Y series High COP (12hp) Heat Pump Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYEP00YLMA /.7.79 /.97 ~10% OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz / 18.9 [2.1] 20~15.5 / 5~ PUHYEPYLMA1 PUHYEP0YLMA1 PUHYEP5YsLMA1 PUHYEP00YsLMA /.8.85 / ~10% OU Capacity (11/8 ) (5/8 ) v, Hz / 22.8 [8.0] 20~15.5 / 5~ / / 7.28 ~10% OU Capacity (11/8 ) (5/8 ) v, Hz 8 0. / 28.9 [.5] 20~15.5 / 5~ / / ~10% OU Capacity 200 / (11/8 ) (5/8 ) v, Hz 8 / / 25. [ ] 20~15.5 / 5~ / / / 7.5 ~10% OU Capacity 200 / (11/8 ) (5/8 ) v, Hz 8 / 8 0. / 28.7 [ ] 20~15.5 / 5~ / 1 25 PriCE 9,277 10,55 11,892 1,070 1,7 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

77 Air Conditioning Y series High COP (20hp) Heat Pump Outdoor Unit Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PriCE PUHYEPYsLMA1 PUHYEP700YsLMA1 PUHYEP7YsLMA / / 8.8 ~10% OU Capacity 175 / 175 / (11/8 ) (5/8 ) v, Hz 8 / 8 / / 28.0 [ ] 20~15.5 / 5~ / 1 20 / / / 8.29 ~10% OU Capacity 200 / 175 / (1/8 ) (/ ) v, Hz 8 / 8 / 8. / 1.1 [ ] 20~15.5 / 5~ / 1 20 / /.89.1 / 8.79 ~10% OU Capacity 200 / 175 / (1/8 ) (/ ) v, Hz 8 / 8 / 8.9 /.7 [ ] 20~15.5 / 5~ / 1 20 / ,19 1,58 17,7 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

78 Y series High COP (2hp) Heat Pump Outdoor Unit HiGH EFFiCiENCY HEAt PUMP CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PriCE PUHYEP800YsLMA1 PUHYEP8YsLMA1 PUHYEP900YsLMA /.8.0 / 7.5 ~10% OU Capacity 200 / 200 / (1/8 ) (/ ) v, Hz 8 / 8 / /.2 [ ] 20~15.5 / 5~ / 1 25 / /.7.0 / 7.8 ~10% OU Capacity 200 / 200 / (15/8 ) (/ ) v, Hz 8 / 8 / / 9. [ ] 20~15.5 / 5~ / 1 25 / / / 7.58 ~10% OU Capacity 200 / 200 / (15/8 ) (/ ) v, Hz 8 / 8 / 8.8 / 2.0 [ ] 20~15.5 / 5~ / 1 25 / ,201 20,79 21,81 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

79 1.5.1 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Y series replace Multi (822hp) Heat Pump Outdoor Unit OUtDOOR UNitS PUHYrP200YJMB PUHYrP2YJMB PUHYrP00YJMB PUHYrPYJMB PUHYrP00YsJMB PUHYrPYsJMB PUHYrP0YsJMB PUHYrP5YsJMB CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* /.9 / % OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz 8 8.7/8.7 [1.5] 20~15.5 / 5~ earth /.7 / % OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz /12.7 [18.] 20~15.5 / 5~ earth /.7 / % OU Capacity (11/8 ) 12.7 (1/2 ) v, Hz /1. [21.5] 20~15.5 / 5~ earth /.9 / % OU Capacity (1/8 ) (5/8 ) v, Hz /18.9 [28.] 20~15.5 / 5~ earth /.79 / % OU Capacity 185 / (1/8 ) (5/8 ) v, Hz /18. [ ] 20~15.5 / 5~ 1 20 / earth /. / % OU Capacity 185 / (1/8 ) (5/8 ) v, Hz /22.2 [ ] 20~15.5 / 5~ 1 20 / earth /.57 / % OU Capacity 185 / (1/8 ) (5/8 ) v, Hz /2.2 [ ] 20~15.5 / 5~ 1 20 / earth /.0 / % OU Capacity 185 / (1/8 ) (5/8 ) v, Hz /28.7 [ ] 20~15.5 / 5~ 1 25 / earth PriCE 5,581,975 8,71 9,75 11,205 12,599 1,99 15,89 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

80 Y series replace Multi (2hp) Heat Pump Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUHYrP00YsJMB /.71 / % OU Capacity 185 / (1/8 ) (/ ) v, Hz /0.8 [ ] 20~15.5 / 5~ 1 25 / earth PUHYrPYsJMB /. / % OU Capacity 185 / (15/8 ) (/ ) v, Hz /.0 [ ] 20~15.5 / 5~ 1 2 / earth PUHYrP700YsJMB PUHYrP7YsJMB PUHYrP800YsJMB /.0 / ~10% OU Capacity 185 / 185 / (15/8 ) (/ ) v, Hz /. [ ] 20~15.5 / 5~ 1 20 / 1 20 / earth /.52 / ~10% OU Capacity 185 / 185 / (15/8 ) (/ ) v, Hz / 9.7 [ ] 20~15.5 / 5~ 1 20 / 1 20 / earth /.5 / ~10% OU Capacity 185 / 185 / (15/8 ) (/ ) v, Hz / 2.0 [ ] 20~15.5 / 5~ 1 25 / 1 20 / earth PUHYrP8YsJMB /.5 / ~10% OU Capacity 185 / 185 / (15/8 ) (/ ) v, Hz /.1 [ ] 20~15.5 / 5~ 1 25 / 1 25 / earth PUHYrP900YsJMB /.57 / ~10% OU Capacity 185 / 185 / (15/8 ) (/ ) v, Hz / 5.7 [ ] 20~15.5 / 5~ 1 25 / 1 25 / earth PriCE 1,785 18,179 19,22 21,01 22,12 2,808 25,20 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

81 1.5.1 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges r2 series standard (818hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUrYP200YLMA1 PUrYP2YLMA1 PUrYP00YLMA1 PUrYPYLMA1 PUrYP00YLMA1 PUrYPYLMA /.2.9 / ~1% OU Capacity (/ ) (5/8 ) v, Hz / 8. [1.1] 20~15.5 / 5~ earth / / / / ~1% OU Capacity ~1% OU Capacity (7/8 ) 22.2 (7/8 ) (/ ) (/ ) v, Hz 8015v, Hz / 11.1 [17.] 15.0 / 1.5 [22.2] 20~15.5 / 5~ 20~15.5 / 5~ earth + earth /.0.9 / / /. 5 0 ~1% OU Capacity ~1% OU Capacity (11/8 ) (11/8 ) (/ ) 22.2 (7/8 ) v, Hz 8015v, Hz / 18.8 [27.8] 18. / 21.9 [2.] 20~15.5 / 5~ 20~15.5 / 5~ earth + earth /.9.80 /.25 5 ~1% OU Capacity (11/8 ) 22.2 (7/8 ) v, Hz / 22.9 [5.9] 20~15.5 / 5~ earth PriCE,7 5,59,719 7,921 9,5 10,7 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

82 r2 series standard (2028hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUrYP0YLMA1 PUrYP5YsLMA1 PUrYP00YsLMA1 PUrYPYsLMA1 PUrYP700YsLMA / /.7.82 / /.7 ~1% OU Capacity ~1% OU Capacity / (11/8 ) (11/8 ) 22.2 (7/8 ) (11/8 ) v, Hz 8015v, Hz 8 / 8 8 / / 28. [1.9] 2. / 27.0 [ ] 20~15.5 / 5~ 20~15.5 / 5~ / earth + earth / /.0 ~1% OU Capacity 20 / (11/8 ) (11/8 ) v, Hz 8 / 8 0. / 0.9 [ ] 20~15.5 / 5~ 1 25 / earth /. 5.0 /.1 ~1% OU Capacity 20 / (11/8 ) (11/8 ) v, Hz 8 / 8.1 /.1 [ ] 20~15.5 / 5~ 1 2 / earth / / 5.8 ~1% OU Capacity 20 / 20.9 (1/8 ) (11/8 ) v, Hz 8 / 8. / 8.8 [ ] 20~15.5 / 5~ 1 2 / earth PriCE 11,2 12,7 1,570 1,772 1,20 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

83 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges r2 series standard (0hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS PUrYP7YsLMA1 PUrYP800YsLMA1 PUrYP8YsLMA1 PUrYP900YsLMA1 CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal).91 /.2.9 / / /.9 SCOp / SEER (system).77 /.28.5 /..5 /.7.80 /.5 MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity airflow (m /min) High 20 / / / / 20 pipe SiZE mm (in) Gas.9 (1/8 ).9 (1/8 ) 1.28 (15/8 ) 1.28 (15/8 ) Liquid (11/8 ) (11/8 ) (11/8 ) (11/8 ) SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy* 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz phase* STaRTiNg CURRENT (a)* 8 / 8 8 / 8 8 / 8 8 / 8 NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX].9 / 2.0 [ ]. / 5. [2.+2.] 2.0 /.9 [5.+2.] 8. / 7.7 [5.+5.] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ FUSE RaTiNg (MCB sizes BS EN 0972) (a)* 1 0 / / / / 1 0 MaiNS CaBLE No. Cores* + earth + earth + earth + earth PriCE 17,0 18,820 19,972 20,98 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

84 r2 series High COP (820hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS PUrYEP200YLMA1 PUrYEP2YLMA1 PUrYEP00YLMA1 PUrYEPYLMA1 PUrYEP00YLMA1 PUrYEPYLMA1 PUrYEP0YLMA1 CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal).90 / /.8.7 /.7.8 /.18.7 /.58.5 /.7.22 /.0 SCOp / SEER (system) 5.0 / / / /.5.59 /.85.9 / /.79 MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity airflow (m /min) High pipe SiZE mm (in) Gas (/ ) 22.2 (7/8 ) 22.2 (7/8 ) (11/8 ) (11/8 ) (11/8 ) (11/8 ) Liquid (5/8 ) (/ ) (/ ) (/ ) 22.2 (7/8 ) 22.2 (7/8 ) 22.2 (7/8 ) SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz phase* STaRTiNg CURRENT (a)* / 8 8 / 8 8 / 8 NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] 9.9 / 8. [1.1] 1.0 / 11.2 [19.9] 15. / 1.2 [2.] 19.9 / 19. [0.] 20.7 / 19. [1.7] 2.5 / 22.9 [7.] 0.2 / 28.2 [.1] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PriCE 5,092, 7,8 9,017 10,1 11,58 1,001 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

85 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges r2 series High COP (2228hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS PUrYEP5YsLMA1 PUrYEP00YsLMA1 PUrYEPYsLMA1 PUrYEP700YsLMA1 CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal).7 /..7 /.5.2 /.0.8 /.08 SCOp / SEER (system) 5.0 / / / /.70 MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity ~1% OU Capacity airflow (m /min) High 20 / / / / 20 pipe SiZE mm (in) Gas (11/8 ) (11/8 ) (11/8 ).9 (1/8 ) Liquid (11/8 ) (11/8 ) (11/8 ) (11/8 ) SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * 8015v, Hz 8015v, Hz 8015v, Hz 8015v, Hz phase* STaRTiNg CURRENT (a)* 8 / 8 8 / 8 8 / 8 8 / 8 NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] 28.5 / 2.8 [ ] 1. / 0.2 [2.+2.].7 /.1 [0.+2.] 9.0 / 0.1 [0.+0.] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ 20~15.5 / 5~ FUSE RaTiNg (MCB sizes BS EN 0972) (a)* 1 25 / / / / 1 2 MaiNS CaBLE No. Cores* PriCE 1,5 15,959 17,12 18,29 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

86 r2 series High COP (0hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy * phase* STaRTiNg CURRENT (a)* NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a)* MaiNS CaBLE No. Cores* PUrYEP7YsLMA1 PUrYEP800YsLMA1 PUrYEP8YsLMA1 PUrYEP900YsLMA / /.80 ~1% OU Capacity 20 / 20.9 (1/8 ) (11/8 ) v, Hz 8 / / 0.1 [1.7+0.] 20~15.5 / 5~ 1 2 / /.7.78 /.88 ~1% OU Capacity 20 / 20.9 (1/8 ) (11/8 ) v, Hz 8 / 8 1. / 0.0 [ ] 20~15.5 / 5~ 1 2 / /.7.8 / 7.1 ~1% OU Capacity 20 / (15/8 ) (11/8 ) v, Hz 8 / /.0 [7.+1.7] 20~15.5 / 5~ 1 0 / /.2.9 / 7.19 ~1% OU Capacity 20 / (15/8 ) (11/8 ) v, Hz 8 / 8 9. / 7.8 [7.+7.] 20~15.5 / 5~ 1 0 / 1 0 PriCE 19,592 20,891 22,2 2,575 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

87 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges r2 series replace Multi (812hp) simultaneous Heating and Cooling with Heat recovery Outdoor Unit OUtDOOR UNitS CapaCiTy (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) power input (kw) Heating (nominal) High Performance Heating (UK) COP Priority Heating (UK) Cooling (UK) COp / EER (nominal) SCOp / SEER (system) MaX No. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy airflow (m /min) High pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth (1mm without legs) Height ELECTRiCaL SUppLy phase STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating /Cooling [MAX] guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling FUSE RaTiNg (MCB sizes BS EN 0972) (a) MaiNS CaBLE No. Cores PUrYrP200YJMB PUrYrP2YJMB PUrYrP00YJMB /.52 / ~1% OU Capacity (11/8 ) (/ ) v, Hz / 8.0 [11.8] 20~15.5 / 5~ earth /.10 /. 25 ~1% OU Capacity (11/8 ) (/ ) v, Hz / 11.2 [1.] 20~15.5 / 5~ earth /.01 /.8 0 ~1% OU Capacity (11/8 ) (/ ) v, Hz 8 1. / 1. [20.0] 20~15.5 / 5~ earth PriCE,17 8,02 9,2

88 WY series (820hp) Heat Pump, Water Cooled Condensing Unit CONDENSiNG UNitS CapaCiTy (kw) Heating (nominal) power input (kw) Heating (nominal) OpERaTiNg WaTER VOLUME (m /h) guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling COp / EER (nominal) SCOp / SEER (system) MaX NO. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy pipe SiZE mm (in) gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating / Cooling [MaX] FUSE RaTiNg (BS88) HRC (a)* MaiNS CaBLE No. Cores* PQHYP200YLMA PQHYP2YLMA PQHYP00YLMA PQHYPYLMA PQHYP00YLMA PQHYP00YsLMA PQHYPYLMA PQHYPYsLMA PQHYP0YLMA PQHYP0YsLMA ~ 7.2 5~5 / 5~5.29 /.0.9 /.2 17 ~ 10% (/") 9.52 (/8") v, Hz 8.1 / 5.7 [1.1] 1 20A + earth ~ 7.2 5~5 / 5~5.20 / / ~ 10% 22.2 (7/8") 9.52 (/8")** v, Hz / 7.5 [1.1] 1 20A + earth ~ 7.2 5~5 / 5~5.25 / /.0 2 ~ 10% 22.2 (7/8") 9.52 (/8")** v, Hz ~ 11. 5~5 / 5~ / / ~ 10% (1 1/8") 12.7 (1/2") v, Hz ~ 11. 5~5 / 5~ / /.0 ~ 10% (1 1/8") (5/8") v, Hz ~ ~5 / 5~5.29 / /. ~ 10% (1 1/8") (5/8") v, Hz 8 / ~ 11. 5~5 / 5~ / /.82 9 ~ 10% (1 1/8") (5/8") v, Hz ~ ~5 / 5~5.2 / /.9 9 ~ 10% (1 1/8") (5/8") v, Hz 8 / ~ 11. 5~5 / 5~ / /.82 ~ 10% (1 1/8") (5/8") v, Hz ~ ~5 / 5~5.20 / / 7.25 ~ 10% (1 1/8") (5/8") v, Hz 8 / 8 9. / 9. [18.] 11. / 11.0 [2.1] 12.9 / 12. [27.] 12.2 / 11.9 [ ] 15.1 / 1. [2.9] 1.8 / 1.5 [ ] 17. / 17.2 [9.2] 15.7 / 15. [ ] 1 20A + earth 1 25A + earth 1 2A + earth 1 20A / 1 20A + earth 1 0A + earth 1 20A / 1 20A + earth 1 0A + earth 1 20A / 1 20A + earth PriCE 5,99 7,022 8,8 9, 10,2 11,79 11,522 12,802 12,71 1,125 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

89 1.5.2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges WY series (22hp) Heat Pump, Water Cooled Condensing Unit CONDENSiNG UNitS CapaCiTy (kw) Heating (nominal) power input (kw) Heating (nominal) OpERaTiNg WaTER VOLUME (m /h) guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling COp / EER (nominal) SCOp / SEER (system) MaX NO. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy pipe SiZE mm (in) gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating / Cooling [MaX] FUSE RaTiNg (BS88) HRC (a)* MaiNS CaBLE No. Cores* PQHYP5YLMA PQHYP5YsLMA PQHYP00YLMA PQHYP00YsLMA PQHYP700YsLMA PQHYP7YsLMA PQHYP800YsLMA PQHYP8YsLMA PQHYP900YsLMA ~ ~ ~ ~ ~ ~ ~ ~ ~ ~5 / 5~5 5.2 / /.88 7 ~ 10% (1 1/8") (5/8") v, Hz 8 5~5 / 5~5.10 / / ~ 10% (1 1/8") (5/8") v, Hz 8 / 8 5~5 / 5~ / /.2 ~ 10% (1 1/8") (5/8") v, Hz 8 5~5 / 5~5.00 / /.95 ~ 10% (1 1/8") (5/8") v, Hz 8 / 8 5~5 / 5~ / /.98 ~ 10%.9 (1 /8") (/") v, Hz 8 / 8 5~5 / 5~ / / 7.05 ~ 10%.9 (1 /8") (/") v, Hz 8 / 8 5~5 / 5~ / 5..1 /.97 ~ 10%.9 (1 /8") (/") v, Hz 8 / 8 5~5 / 5~5 5.8 / /.8 ~ 10% 1.28 (1 5/8") (/") v, Hz 8 / 8 5~5 / 5~ / /.9 ~ 10% 1.28 (1 5/8") (/") v, Hz 8 / / 19. [0.5] 17. / 17.8 [ ] 22. / 22. [0.5] 19.7 / 19.8 [ ] 22.7 / 22.7 [ ] 2.5 / 2.1 [ ] 25.8 / 25. [ ] 28.5 / 27.8 [ ] 0.5 / 29.9 [ ] 1 A + earth 1 20A / 1 20A + earth 1 A + earth 1 20A / 1 20A + earth 1 25A / 1 25A + earth 1 2A / 1 25A + earth 1 2A / 1 2A + earth 1 0A / 1 2A + earth 1 0A / 1 0A + earth PriCE 1,925 15,71 15,1 1,817 18,797 19,779 20,71 21,951 2,11 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building.

90 Wr2 series (820hp) Water Cooled Condensing Unit simultaneous Heating and Cooling with double Heat recovery CONDENSiNG UNitS CapaCiTy (kw) Heating (nominal) power input (kw) Heating (nominal) OpERaTiNg WaTER VOLUME (m /h) guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling COp / EER (nominal) SCOp / SEER (system) MaX NO. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy pipe SiZE mm (in) gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating / Cooling [MaX] FUSE RaTiNg (BS88) HRC (a)* MaiNS CaBLE No. Cores* PQrYP200YLMA PQrYP2YLMA PQrYP00YLMA PQrYPYLMA PQrYP00YLMA PQrYP00YsLMA PQrYPYLMA PQrYPYsLMA PQrYP0YLMA PQrYP0YsLMA ~ 7.2 5~5 / 5~5.29 /.0.22 / ~ 1% (/") (5/8") v, Hz 8.1 / 5.7 [1.1] 1 20A + earth ~ 7.2 5~5 / 5~5.20 / /.9 25 ~ 1% 22.2 (7/8") (/") v, Hz / 7.5 [1.1] 1 20A + earth ~ 7.2 5~5 / 5~5.25 / /.1 0 ~ 1% 22.2 (7/8") (/") v, Hz ~ 11. 5~5 / 5~ / / ~ 1% (1 1/8") 22.2 (7/8") v, Hz ~ 11. 5~5 / 5~ / / ~ 1% (1 1/8") 22.2 (7/8") v, Hz ~ ~5 / 5~5.29 / /.08 0 ~ 1% (1 1/8") 22.2 (7/8") v, Hz 8 / ~ 11. 5~5 / 5~ / /. 5 ~ 1% (1 1/8") 22.2 (7/8") v, Hz ~ ~5 / 5~5.2 / /. 5 ~ 1% (1 1/8") 22.2 (7/8") v, Hz 8 / ~ 11. 5~5 / 5~ / /.2 ~ 1% (1 1/8") 22.2 (7/8") v, Hz ~ ~5 / 5~5.20 / /.9 ~ 1% (1 1/8") 22.2 (7/8") v, Hz 8 / 8 9. / 9. [18.] 11. / 11.0 [2.1] 12.9 / 12. [27.] 12.2 / 11.9 [ ] 15.1 / 1. [2.9] 1.8 / 1.5 [ ] 17. / 17.2 [9.2] 15.7 / 15. [ ] 1 20A + earth 1 25A + earth 1 2A + earth 1 20A / 1 20A + earth 1 0A + earth 1 20A / 1 20A + earth 1 0A + earth 1 20A / 1 20A + earth PriCE 5,99 7,022 8,8 9,1 10, 11,27 11,55 12,9 12,8 1,27 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

91 1.5.2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Wr2 series (22hp) Water Cooled Condensing Unit simultaneous Heating and Cooling with double Heat recovery CONDENSiNG UNitS CapaCiTy (kw) Heating (nominal) power input (kw) Heating (nominal) OpERaTiNg WaTER VOLUME (m /h) guaranteed OpERaTiNg RaNgE (ºC) Heating / Cooling COp / EER (nominal) SCOp / SEER (system) MaX NO. OF CONNECTaBLE indoor UNiTS MaX CONNECTaBLE CapaCiTy pipe SiZE mm (in) gas Liquid SOUND pressure LEVEL (dba) SOUND power LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* phase* STaRTiNg CURRENT (a) NOMiNaL SySTEM RUNNiNg CURRENT (a)* Heating / Cooling [MaX] FUSE RaTiNg (BS88) HRC (a)* MaiNS CaBLE No. Cores* PQrYP5YLMA PQrYP5YsLMA PQrYP00YLMA PQrYP00YsLMA PQrYP700YsLMA PQrYP7YsLMA PQrYP800YsLMA PQrYP8YsLMA PQrYP900YsLMA ~ 1. 5~5 / 5~5 5.2 / /.2 ~ 1% (1 1/8") 22.2 (7/8")** v, Hz / 19. [0.5] 1 A + earth ~ ~5 / 5~5.10 / / 7.0 ~ 1% (1 1/8") 22.2 (7/8")** v, Hz 8 / / 17.8 [ ] 1 20A / 1 20A + earth ~ 1. 5~5 / 5~ / / 5.9 ~ 1%.9 (1 /8") 22.2 (7/8")** v, Hz / 22. [0.5] 1 A + earth ~ ~ ~ ~ ~ ~ ~5 / 5~5.00 / /.55 ~ 1%.9 (1 /8") 22.2 (7/8")** v, Hz 8 / / 19.8 [ ] 1 20A / 1 20A + earth 5~5 / 5~ / /.5 ~ 1%.9 (1 /8") (1 1/8") v, Hz 8 / / 22.7 [ ] 1 25A / 1 25A + earth 5~5 / 5~ / /.5 ~ 1%.9 (1 /8") (1 1/8") v, Hz 8 / / 2.1 [ ] 1 2A / 1 25A + earth 5~5 / 5~ / /.0 ~ 1%.9 (1 /8") (1 1/8") v, Hz 8 / / 25. [ ] 1 2A / 1 2A + earth 5~5 / 5~5 5.8 / /.9 ~ 1% 1.28 (1 5/8") (1 1/8") v, Hz 8 / / 27.8 [ ] 1 0A / 1 2A + earth 5~5 / 5~ / /.8 ~ 1% 1.28 (1 5/8") (1 1/8") v, Hz 8 / / 29.9 [ ] 1 0A / 1 0A + earth PriCE 1,058 15,19 15,28 1,95 19,108 20,15 21,20 22,95 2,58 Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building.

92 PFdPVME (10/20hp) Close Control system CLOSE CONtROL UNitS PFdP2VME PFdP0VME* 1 CapaCiTy (kw) SHF (nominal) power input (kw) airflow (l/s) High EXTERNaL STaTiC pressure (pa) pipe SiZE mm (in) Gas Liquid SOUND pressure LEVEL (dba) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase STaRTiNg CURRENT (a) RUNNiNg CURRENT (a) Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (7/8 ) 9.52 (/8 ) v, Hz earth (7/8 )* (/8 )* v, Hz earth PriCE 9,11 10,7 PiPiNG REStRiCtiONS TOTaL piping LENgTH BETWEEN indoor and OUTDOOR UNiTS HEigHT PFdPVME 15m ma m ma (0m ma if outdoor installed below) Notes: *1 2 PUHYP2YJMA units are needed when connected to a PFDP0VME. *2 PFDP0VME uses two refrigerant circuits. Pipe sizes are per single refrigerant circuit Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

93 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PLFYPVEME Way Blow Ceiling Cassette indoor Unit indoor UNitS PLFYP2VEME PLFYP0VEME PLFYPVEME PLFYPVEME PLFYP80VEME PLFYP100VEME PLFYP125VEME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMi1Mi2Hi SOUND pressure LEVEL (dba) LoMi1Mi2Hi WEigHT (kg) (Grille) DiMENSiONS (mm) Width (Grille) Depth (Grille) Height (Grille) ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores grille MODEL REFERENCE () () () () () () () (5) 80 (9) 80 (9) 258 (0) 22020v, Hz plpea (5 80 (9) 80 (9) 258 (0) 22020v, Hz plpea (5) 80 (9) 80 (9) 258 (0) 22020v, Hz plpea (5) 80 (9) 80 (9) 258 (0) 22020v, Hz plpea (5) 80 (9) 80 (9) 258 (0) 22020v, Hz plpea (5) 80 (9) 80 (9) 298 (0) 22020v, Hz plpea (5) 80 (9) 80 (9) 298 (0) 22020v, Hz plpea PriCE ,00 1,21 Note: Indoor price includes PLPEA grille. * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately.

94 PLFYPVFME 0000 Way Blow Ceiling Cassette Indoor Unit INDOOR UNITS PLFYP15VFME PLFYP20VFME PLFYP25VFME PLFYP2VFME PLFYP0VFME PLFYPVFME CAPACity (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) POWER input (kw) Heating (nominal) AiRFLOW (l/s) LoMiHi SOUND PRESSURE LEVEL (dba) LoMiHi WEigHt (kg) (Grille) DimENSiONS (mm) Width (Grille) Depth (Grille) Height (Grille) ELECtRiCAL SUPPLy PHASE RUNNiNg CURRENt (A) Heating / Cooling FUSE RAtiNg (BS88) HRC (A) mains CABLE No. Cores grille model REFERENCE (1.0) () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.1 / 0.19 SLP2FA (1.0) () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.1 / 0.21 SLP2FA (2.00) () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.17 / 0.22 SLP2FA (2.0) () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.18 / 0.2 SLP2FA (2.90) () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.2 / 0.28 SLP2FA (.0).78.1 () () 570 (25) 570 (25) 25 (10) 22020v, Hz 0.5 / 0. SLP2FA PRICE Note: Indoor price includes SLP2FA grille. * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

95 1.5.0 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PEFYPVMs1E Ultra thin Ceiling Concealed ducted indoor Unit indoor UNitS PEFYP15VMs1E PEFYP20VMs1E PEFYP25VMs1E PEFYP2VMs1E PEFYP0VMs1E PEFYPVMs1E PEFYPVMs1E CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (Pa) SOUND pressure LEVEL (dba)** LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.0) (1.) v, Hz 0.1 / (1.70) (1.) v, Hz 0. / (2.10) (1.9) v, Hz 0.9 / (2.) (2.) v, Hz 0.9 / (.00) (2.7) v, Hz 0.5 / (.70) (.) v, Hz 0.5 / (.70) (.2) v, Hz 0.1 / 0.72 PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. ** Additional sound data is available for this model. Separated inlet and breakout sound power level and discharge sound power level data is available on request.

96 PEFYPVMAE Ceiling Concealed ducted indoor Unit indoor UNitS CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (Pa) SOUND pressure LEVEL (dba)** (pa) LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores PEFY P20VMAE (1.80) (1.7) v, Hz 0.2 / 0.5 PEFY P25VMAE (2.00) (1.8) v, Hz 0.2 / 0.5 PEFY P2VMAE (2.) (2.2) v, Hz 0. / 0.55 PEFY P0VMAE (.0).9.7. (.0) v, Hz 0.5 / 0. PEFY PVMAE (.10) (.7) v, Hz 0. / 0.7 PEFY PVMAE (5.10) (.) v, Hz 0.90 / 1.01 PEFY P80VMAE (5.90) (5.) v, Hz 1.0 / 1.15 PEFY P100VMAE (8.10) (7.) v, Hz 1. / 1.7 PEFY P125VMAE (9.90) (9.0) v, Hz 1.9 / 2.05 PriCE ,021 Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. ** Additional sound data is available for this model. Separated inlet and breakout sound power level and discharge sound power level data is available on request Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

97 1.5.2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PEFYPVMH(s)E High static Pressure Ceiling Concealed ducted indoor Unit indoor UNitS PEFYP80VMHE PEFYP100VMHE PEFYP125VMHE PEFYP10VMHE PEFYP200VMHsE PEFYP2VMHsE CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoHi EXTERNaL STaTiC pressure (Pa) SOUND pressure LEVEL (dba) (1pa) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (.10) v, Hz 1.7 / (8.0) v, Hz 2. / (9.) v, Hz 2. / (10.80) v, Hz 2.5 / (15.0) v, Hz.18 / (19.0) v, Hz.1 /.1 PriCE 1,21 1,2 1,57 1,91 2,00 2,2 Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately.

98 PCFYPVKME Ceiling suspended indoor Unit indoor UNitS PCFYP0VKME PCFYPVKME PCFYP100VKME PCFYP125VKME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMi1Mi2Hi SOUND pressure LEVEL (dba) LoMi1Mi2Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (.00) v, Hz 0.28 / (.0) v, Hz 0. / (7.10) v, Hz 0.5 / (8.90) v, Hz 0.7 / 0.7 PriCE 95 1,07 1,288 1,8 Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

99 1.5. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PKFYPVBME / VHME / VKME Wall Mounted indoor Units indoor UNitS PKFYP15VBME PKFYP20VBME PKFYP25VBME PKFYP2VHME PKFYP0VHME PKFYPVHME PKFYPVKME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMi1Mi2Hi SOUND pressure LEVEL (dba) LoMi1Mi2Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.10) (1.0) v, Hz 0.20 / (1.0) (1.) v, Hz 0.20 / (1.80) (1.) v, Hz 0.20 / (2.) (2.) v, Hz 0.0 / (.10) (2.8) v, Hz 0.0 / (.0) (.2) v, Hz 0.0 / (5.00) (.5) v, Hz 0.0 / 0.7 PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately. PKFYP15/20/25VBME should not be used with PUMYP and PUHY(E)P models in sound sensitive spaces (such as hotel bedrooms).

100 PFFYPVLrME Floor standing Concealed indoor Unit indoor UNitS PFFYP20VLrME PFFYP25VLrME PFFYP2VLrME PFFYP0VLrME PFFYPVLrME PFFYPVLrME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoHi SOUND pressure LEVEL** (dba) LoHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.0) v, Hz 0.19 / (1.90) v, Hz 0.19 / (2.0) v, Hz 0.29 / (.00) v, Hz 0.2 / (.80) v, Hz 0.0 / (.70) v, Hz 0. / 0. PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately. ** Additional sound data is available for this model. Separated inlet and breakout sound power level and discharge sound power level data is available on request Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

101 1.5. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PFFYPVLrMME Floor standing Concealed indoor Unit indoor UNitS PFFYP20VLrMME PFFYP25VLrMME PFFYP2VLrMME PFFYP0VLrMME PFFYPVLrMME PFFYPVLrMME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (pa) SOUND pressure LEVEL (dba)** (20pa) LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.0) v, Hz 0. / (1.90) v, Hz 0. / (2.0) v, Hz 0.8 / (.00) v, Hz 0. / (.80) v, Hz 0.8 / (.70) v, Hz 0.59 / 0.59 PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately. ** Additional sound data is available for this model. Separated inlet and breakout sound power level and discharge sound power level data is available on request.

102 PFFYPVLEME Floor standing Eposed indoor Unit indoor UNtS PFFYP20VLEME PFFYP25VLEME PFFYP2VLEME PFFYP0VLEME PFFYPVLEME PFFYPVLEME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoHi SOUND pressure LEVEL (dba) LoHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.0) (1.90) (2.0) (.00) (.80) (.70) v, Hz 0.19 / v, Hz 0.19 / v, Hz 0.29 / v, Hz 0.2 / v, Hz 0.0 / v, Hz 0. / 0. PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

103 1.5.8 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PFFYPVKME Floor standing Eposed indoor Unit indoor UNitS PFFYP20VKME PFFYP25VKME PFFYP2VKME PFFYP0VKME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo UK Total Cooling Hi (Sensible) (Raised Evaporation Temperature*) power input (kw) Heating (nominal) airflow (l/s) LoMi1Mi2Hi SOUND pressure LEVEL (dba) LoMi1Mi2Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.0) v, Hz 0.20 / (1.90) v, Hz 0.20 / (2.0) v, Hz 0.20 / (2.90) v, Hz 0.2 / 0.2 PriCE Notes: * Figures shown using 9 C Raised Evaporation Temperature. PUHY(E)P YKB/YLM and PURY(E)P YLM models have an option for C and 1 C Evaporation Temperature. Please consult with your sales office for application of this feature. The data for this model is available separately.

104 PLFYWPVBME (HVrF) Way Blow Ceiling Cassette indoor Unit indoor UNitS PLFYWP2VBME PLFYWP0VBME PLFYWPVBME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo power input (kw) Heating (nominal) airflow (l/s) LoMi1Mi2Hi SOUND pressure LEVEL (dba) LoMi1Mi2Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores grille MODEL REFERENCE (.20) v, /0Hz 0.28 / 0.5 plpba (.0) v, /0Hz 0.28 / 0.5 plpba (.20) v, /0Hz 0.8 / 0.5 plpba PriCE Notes: Indoor price includes PLPBA grille. HVRF indoor units can only be configured with the CMBWP HBC (HVRF) and PURY(E)P YLMA or PQRYP YLMA outdoor units. Indoor unit water connections / BSP screw Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

105 1.5.0 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PEFYWPVMs1E (HVrF) Ultra thin Ceiling Concealed ducted indoor Unit indoor UNitS PEFYWP15VMs1E PEFYWP20VMs1E PEFYWP25VMs1E PEFYWP2VMs1E PEFYWP0VMs1E PEFYWPVMs1E CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (Pa) SOUND pressure LEVEL (dba) LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.) v, Hz 0. / (1.70) v, Hz 0.8 / (2.00) v, Hz 0.0 / (2.70) v, Hz 0. / (.20) v, Hz 0.2 / (.00) v, Hz 0. / 0.77 PriCE Notes: HVRF indoor units can only be configured with the CMBWP HBC (HVRF) and PURY(E)P YLMA or PQRYP YLMA outdoor units. Indoor unit water connections / BSP screw.

106 PEFYWPVMAE (HVrF) Ceiling Concealed ducted indoor Unit indoor UNitS PEFYWP20VMAE PEFYWP25VMAE PEFYWP2VMAE PEFYWP0VMAE PEFYWPVMAE CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (Pa) SOUND pressure LEVEL (dba) (pa) LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.80) v, Hz 0. / (2.) v, Hz 0.5 / (.00) v, Hz 0. / (.80) v, Hz 1.0 / (.20) v, Hz 1.15 / 1.15 PriCE Notes: HVRF indoor units can only be configured with the CMBWP HBC (HVRF) and PURY(E)P YLMA or PQRYP YLMA outdoor units. Indoor unit water connections / BSP screw Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

107 1.5.2 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PFFYWPVLrMME (HVrF) Floor standing Concealed indoor Unit indoor UNitS PFFYWP20VLrMME PFFYWP25VLrMME PFFYWP2VLrMME PFFYWP0VLrMME PFFYWPVLrMME CapaCiTy (kw) Heating (nominal) UK Heating UK Total Cooling Hi (Sensible) UK Total Cooling Mi2 UK Total Cooling Mi1 UK Total Cooling Lo power input (kw) Heating (nominal) airflow (l/s) LoMiHi EXTERNaL STaTiC pressure (pa) SOUND pressure LEVEL (dba) (20pa) LoMiHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) Heating / Cooling FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores (1.) v, Hz 0.5 / (2.00) v, Hz 0.5 / (2.) v, Hz 0.7 / (.10) v, Hz 0.7 / (.90) v, Hz 0.5 / 0.5 PriCE Notes: HVRF indoor units can only be configured with the CMBWP HBC (HVRF) and PURY(E)P YLMA or PQRYP YLMA outdoor units. Indoor unit water connections / BSP screw.

108 GUFrd Lossnay Outdoor Air Processing indoor Unit indoor UNitS CapaCiTy (kw) Heating (nominal) UK Heating (High Performance) UK Heating (COP Priority) UK Total Cooling power input (kw) LoHi airflow (m /h) LoHi EXTERNaL STaTiC pressure (pa) SOUND pressure LEVEL (dba) LoHi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) LoHi FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores GUFrd.21 (2.0) 5.57 (1.9).2 (2.25) 5.9 (2.08) 5.0 (1.58) 0.1 / v, Hz GUF100rd 12.5 (.2) 11. (.12) 1.00 (.70) (.) (.2) 0.70 / v, Hz PriCE 1,72 2,17 Notes: The figures in ( ) indicates the heat recovery at Lossnay core. Total value is capacity of Lossnay core and refrigerant coil. The current and input are based on the above air volume. The sound pressure at the air outlets (5º angle 1.5m ahead) is about db greater than the indicated value. (High notch). Specifications may be subject to change without notice Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

109 1.5. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PWFYPVMEBU VrF sanitary Water Heater SANitARY WAtER HEAtER CapaCiTy (kw) Hot water (nominal)* 1 HEaT pump SpaCE HEaTER 55 C* HEaT pump SpaCE HEaTER 5 C* Hot water (UK)* 2 ErP Rating ɳ s ErP Rating ɳ s power input (kw) COMpaTiBLE OUTDOOR / CONDENSiNg UNiTS REFRigERaNT CHaRgE (kg) High Temp Circuit pipe SiZE mm (in) Gas Liquid Water Connection Water pipe size SOUND pressure LEVEL (dba) MaX WaTER TEMpERaTURE (ºC) OpTiMUM WaTER FLOW RaTE (m /h) WaTER pressure DROp at OpTiMUM FLOW RaTE (kpa) WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores PriCE PWFYP100VMEBU a+ 100% a+ 12% 2.8 pury / pqry 1.1 (R1a) (5/8") 9.52 (/8") pt / Screw (800) 22020v, Hz ,200 Notes: *1 Nominal conditions: Outdoor 7/ºC, 5ºC inlet water temperature, 1.5m /h water flow rate, 7.5m refrigerant pipe. (Please note this is a spot condition and not capacity over tank heat up). *2 Typical capacity at 10ºCWB outdoor temperature for tank heat up. * Combination with PURYP200YLMA1 ɳ s is the seasonal space heating energy efficiency (SSHEE)

110 VrF HP dxe Heat Pump Air Curtain VrF HP dxe recessed VrF HP1000r dxe VrF HP10r dxe VrF HP2000r dxe VrF HP2000r dxe HO * CapaCiTy (kw) Heating (nominal) airflow MaX (l/s) SOUND pressure LEVEL at m (dba) LoMi1Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* 1 phase* 1 RUNNiNg CURRENT (a)* 1 MaiNS CaBLE No. Cores* 1 UNiFORMiTy at OUTLET (%)* 2 UNiT SiZE (inde) MaX MOUNTiNg HEigHT (m) COMpaTiBLE OUTDOOR UNiTS PriCE v, Hz p71.2 puhy / pury / pqhy / pqry v, Hz p125.2 puhy / pury / pqhy / pqry v, Hz p10.2 puhy / pury / pqhy / pqry v, Hz p200.2 puhy / pury / pqhy / pqry,1,8,7,01 VrF HP dxe FrEE standing VrF HP1000 dxe VrF HP10 dxe VrF HP2000 dxe VrF HP2000 dxe HO * CapaCiTy (kw) Heating (nominal) airflow MaX (l/s) SOUND pressure LEVEL at m (dba) LoMi1Hi WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy* 1 phase* 1 RUNNiNg CURRENT (a)* 1 MaiNS CaBLE No. Cores* 1 UNiFORMiTy at OUTLET (%)* 2 UNiT SiZE (inde) MaX MOUNTiNg HEigHT (m) COMpaTiBLE OUTDOOR UNiTS PriCE v, Hz p71.2 puhy / pury / pqhy / pqry v, Hz p125.2 puhy / pury / pqhy / pqry v, Hz p10.2 puhy / pury / pqhy / pqry v, Hz p200.2 puhy / pury / pqhy / pqry 2,99,1,988,252 Notes: *1 For indoor units with electric defrost heaters enabled, ph, 8015V power supply (7.A HP1000, 12.1A HP10, 1.A HP2000). *2 Tested to ISO2727. * Includes twin LEV kit for installation with the air curtain Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

111 1.5. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PACLV11M LEV Kit interface LEV Kit interface MaX NO. OF CONNECTaBLE indoor UNiTS CapaCiTy OF indoor UNiTS COMpaTiBLE OUTDOOR UNiTS COMpaTiBLE indoor UNiTS pipe SiZE mm (in) Gas Liquid WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores PACLV11M 1 20 to puh(r)y(e)p / pqh(r)y(e)p / pumyp VKa/yKM(1) MSZ, MFZ*.5 (1/ ) v, Hz PriCE 20 Notes: Can t be grouped with City Multi indoor units. Group control via ME controller or system controller only. Group control is not possible via an MA controller, IT terminal or wireless remote controller. *MFZ can only be connected to PUMYP VKA/YKM(1)

112 PACMKBC Branch Bo BRANCH BOX MaX NO. OF CONNECTaBLE indoor UNiTS COMpaTiBLE OUTDOOR UNiTS COMpaTiBLE indoor UNiTS* pipe SiZE mm (in) Gas Liquid WEigHT (kg) DiMENSiONS (mm) Width Depth Height ELECTRiCaL SUppLy phase FUSE RaTiNg (BS88) HRC (a) PACMK1BC pumyp112/125/10vkm/ykm MSZ, MFZ, pla, pca, pead, pka, psa, SEZ, SLZ (5/8 ) 9.52 (/8 ) v, Hz PACMK51BC 5 pumyp112/125/10vkm/ykm MSZ, MFZ, pla, pca, pead, pka, psa, SEZ, SLZ (5/8 ) 9.52 (/8 ) v, Hz PriCE 5 1 *City Multi indoor units can be used in conjunction with PACMKBC, M Series and Mr Slim units. Some limitations apply. Please consult your sales office for application of this model Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

113 1.5.8 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges BC Controllers BC COntrOLLErs CMBP10VG1 CMBP105VG1 CMBP10VG1 NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (kw) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Width Depth Height v, Hz v, Hz v, Hz PriCE 1,5 1,78 2,007 Note: CMBPVG1 units are for use with PURYP200 YLMA1, PURYEP200 YLMA1 & PQRYP20000YLMA units only. MAstEr BC COntrOLLErs CMBP108VGA1 CMBP1010VGA1 CMBP101VGA1 CMBP101VGA1 CMBP101VHA1 NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (KW) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Width Depth Height v, Hz v, Hz v, Hz v, Hz v, Hz PriCE 2,0,17,890,75,52 Notes: CMBPVGA1 units are for use with PURYP200Y(S)LMA, PURYEP200Y(S)LMA1 & PQRYP20000Y(S)LMA units only. CMBP101VHA1 unit is for use with PURYP700900YSLMA1 & PURYEP700900YSLMA1 units only. slave BC COntrOLLErs CMBP10VGB1 CMBP108VGB1 CMBP101VHB1 NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (KW) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Width Depth Height v, Hz v, Hz v, Hz PriCE 1,202 2,51,100

114 BC Controllers With Port isolation Valves BC COntrOLLErs Ks8CMBP10VG1B Ks8CMBP105VG1B Ks8CMBP10VG1B NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (kw) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores BC BOX Width Depth Height PriCE v, Hz CMBp10Vg1 Note: KS8CMBPVG1B units are for use with PURYP200 YLMA1, PURYEP200 YLMA1 & PQRYP20000YLMA units only v, Hz CMBp105Vg v, Hz CMBp10Vg1 1,889 2,20 2,0 MAstEr BC COntrOLLErs Ks8CMBP108VGA1B Ks8CMBP1010VGA1B Ks8CMBP101VGA1B Ks8CMBP101VGA1B Ks8P101VHA1B NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (KW) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores BC BOX Width Depth Height PriCE v, Hz CMBp108Vga v, Hz CMBp1010Vga v, Hz CMBp101Vga v, Hz CMBp101Vga v, Hz CMBp101VHa1,201,807,28 5,575 5,02 Notes: KS8CMBPVGA1B units are for use with PURYP200Y(S)LMA1, PURYEP200Y(S)LMA1 & PQRYP20000Y(S)LMA units only. KS8CMBP101VHA1B unit is for use with PURYP700900YLMA1 & PURYEP700900YSLMA1 units only. slave BC COntrOLLErs Ks8CMBP10VGB1B Ks8CMBP108VGB1B Ks8CMBP101VHB1B NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (KW) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores BC BOX Width Depth Height v, Hz CMBp10VgB v, Hz CMBp108VgB v, Hz CMBp101VHB1 PriCE 1,2 2,912, Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

115 1.5. Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges HBC Controllers (HVrF) MAstEr HBC COntrOLLErs CMBWP108VGA1 CMBWP101VGA1 NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (kw) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Width Depth Height 8 85 (95)* 1520 (0) v, Hz (110)* 1800 (0) v, Hz PriCE,88 5,57 slave HBC COntrOLLErs CMBWP108VGB1 CMBWP101VGB1 NUMBER OF CONNECTiONS WEigHT (kg) DiMENSiONS (mm) ELECTRiCaL SUppLy phase power input (kw) RUNNiNg CURRENT (a) FUSE RaTiNg (BS88) HRC (a) MaiNS CaBLE No. Cores Width Depth Height 8 (8)* 1520 (0) v, Hz (0)* 1520 (0) v, Hz PriCE 2,51,51 Notes: CMBWPVGA1 and CMBWPVGB1 units are for use with PURYP2000YLMA1, PURYEP2000YLMA1, PQRYP2000YLMA units and HVRF indoor units only (PLFYWP, PEFYWP, PFFYWP). One main HBC can be used on outdoor units PURY(E)P2002YLMA1, PQRYP2002YLMA. One main HBC can be used on outdoor units PURY(E)P00YLMA1, PQRYP00YLMA with a system efficiency reduction. Two main HBC s can be used in parallel on outdoor units PURY(E)P000YLMA1, PQRYP000YLMA. *( ) Includes Water

116 refrigerant detection systems description MOdEL ref. PriCE standalone refrigerant detectors White recessed back bo semiconductor detector (back bo not supplied) KsGd01WA 178 Silver recessed back bo semiconductor detector (back bo not supplied) White standalone infrared detector KsGd01sA Ksir KSGD01SA Aspirated refrigerant detectors 8 channel aspirated infrared detector panel Ks8ir8CiFA 7,11 1 channel aspirated infrared detector panel Ks8ir1CiFA 8,11 2 channel aspirated infrared detector panel Ks8ir2CiFA 11,20 2m drum sampling tube for aspirated panel (black) Ks8Bst2 12 KSiR01 Stainless steel room faceplate with alarm for aspirated panel Ks8ssFPA 1 Sampling tube two way manifold for aspirated panel Ks8st2M remote display Units Remote alarm display panel for up to 2 semiconductor sensors Ks8rAd2 1,7 Remote alarm display panel for up to semiconductor sensors Ks8rAd 2,10 Remote alarm display panel for up to aspirated infrared detector panels Ks8rdU 1,981 KS8iR1CiFA Accessories 5 wire adaptor for standalone refrigerant detectors used with pump down PACsA88HA 10 Transformer 12VDC Kstr Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

117 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges refrigerant detection systems description MOdEL ref. PriCE City Multi Pump down Control Panels City Multi R2 automatic pump Down Control panel 1 outdoor unit Ks8OC1 1,28 City Multi R2 automatic pump Down Control panel 2 outdoor units Ks8OC2 1,98 City Multi R2 automatic pump Down Control panel outdoor units Ks8OC 2,5 KS8OC1 City Multi R2 automatic pump Down Control panel outdoor units Ks8OC,18 City Multi R2 automatic pump Down Control panel 5 outdoor units Ks8OC5,707 City Multi R2 automatic pump Down Control panel outdoor units Ks8OC,271 City Multi R2 automatic pump Down Control panel 7 outdoor units Ks8OC7,85 City Multi R2 automatic pump Down Control panel 8 outdoor units Ks8OC8 5,99 Actuated Ball Valves for Pump down Operation KS8SSFPA 5/8" actuated ball valve Ks85/8 ABV 158 /" actuated ball valve Ks8/ ABV 18 7/8" actuated ball valve Ks87/8 ABV /8" actuated ball valve Ks81.1/8 ABV 25 1./8" actuated ball valve Ks81./8 ABV /8" actuated ball valve Ks81.5/8 ABV 28

118 City Multi Accessories / Optional Etras description MOdEL ref. PriCE Outdoor Units Branch pipe (Joint) for size 200 or below total capacity of indoor units Branch pipe (Joint) for size total capacity of indoor units Branch pipe (Joint) for size 01 total capacity of indoor units or first branch of p00p / Ep00Ep00 Branch pipe (Joint) for size 51 or above total capacity of indoor units or first branch of p700p12 / EpEp900 Branch pipe for 2 branches (pumy) Twinning Kit for puhyp5yskba1 / puhyep500yslma / pqhyp0000yslma Twinning Kit for puhyp700900yskba1 / pqhyp900yslma Twinning Kit for puhyp912yskba1 / puhyep900yslma Twinning Kit for puhyrp00ysjmb Twinning Kit for puhyrp700900ysjmb Twinning Kit for puryp000yslma1 Twinning Kit for puryp5yslma1 Twinning Kit for puryp700800yslma1 Twinning Kit for puryep5900yslma Twinning Kit for puryp8900yslma1 Twinning Kit for pqryp0000yslma Twinning Kit for pqryp700900yslma Energy Monitoring Connector CMYY102ssG2 CMYY102LsG2 CMYY202sG2 CMYY02sG2 CMYY2GE CMYY100VBK CMYY200VBK2 CMYY00VBK CMYrP100VBK CMYrP200VBK CMYr100VBKA CMYr100VBK2 CMYr200VBK2 CMYEr200VBK CMYr200XLVBK CMYQ100CBK2 CMYQ200CBK PACCn2WHMCUK Way Blow Cassette Units grille for plfypvbme grille for plfypvfme grille and infrared controller for plfypvbme grille with filter lowering function for plfypvbme isee Sensor corner panel for plfypvbme infrared signal receiver for plfypvbme infrared controller for plfypvbme Shutter plate for plfypvbme PLPBA slp2fa PLPBALM PLPBAJ PACsA1MEE PArsA9FAE PArsL97AE PACsH51sP Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

119 1.5.5 Air Conditioning Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges City Multi Accessories / Optional Etras description MOdEL ref. PriCE Ceiling Concealed ducted Units Long life filter for pefyp80vmhe Long life filter for pefyp10010vmhe Long life filter for pefyp2002vmhse Filter bo for pefyp80vmhe (necessary when long life filter is used) Filter bo for pefyp10010vmhe2 (necessary when long life filter is used) Filter bo for pefyp2002vmhse (necessary when long life filter is used) BC Controllers Joint pipe indoor Units Remote Temperature Sensor Discreet Remote Temperature Sensor VrF sanitary Water Heater Controller Thermistor (5m cable) PFd stands Stand for pfdp2vme (leg etensions also available on request to allow different floor heights) Stand for pfdp0vme (leg etensions also available on request to allow different floor heights) PACKE88LAF PACKE89LAF PACKE85LAF PACKE99tB PACKE10tBF PACKE2tBF CMYr10J1 PACsE1tsE Ks9Bs1A PArW21MAAJ therm10m Ks2 Ks

120 Heating Only Heating Only Solutions

121

122 The Innovative Heating Only Solutions With legislation changing and increasing pressure to replace traditional heating systems with renewable sources of heat, the industry needs to be able to provide a wide range of innovative solutions. Building on a comprehensive range of heating products, City Multi Heating Only systems offer a cost effective and efficient solution designed to combat challenging legislation and the need to reduce carbon emissions and running costs. Designed to deliver heat via the air, our full range of air conditioning products can also be adapted with the use of intelligent controls to run as Heating Only products. Why Heating Only Heat Pumps have been developed over the years to enable heating and cooling from one machine, but there are many reasons to use these energy efficient products to provide only heating to a building via the delivery method of air. Many buildings do not need cooling, for eample schools and student accommodation Heat pump air conditioning systems offer a simple, fleible and efficient method of delivering heat to a building Help with Part L Compliance by removing all power consumption related to cooling 1..1 Air Conditioning Heating Only

123 The Innovative Heating Only Solutions Contents City Multi Heating Only Solution Air Conditioning Heating Only

124 Any price shown is our commercial price list (CPL) pricing; e VAT 1.. Air Conditioning Heating Only City Multi Heating Only Solution Price ecludes any special delivery charges AIR SOURCE OPTIONS HEATING ONLY MODEL CHUP200YKB CHUP2YKB CHUP00YKB CHUPYKB CHUP00YKB CHUPYKB STANDARD MODEL EQUIVALENT PUHYP200YKBA1 PUHYP2YKBA1 PUHYP00YKBA1 PUHYPYKBA1 PUHYP00YKBA1 PUHYPYKBA1 PRICE,021 5,02,151 7,17 8,28 9,22 WATER SOURCE OPTIONS HEATING ONLY MODEL CHQP2YHM CHQP00YHM STANDARD MODEL EQUIVALENT PQHYP2YLMA PQHYP00YLMA PRICE 7,022 8,8 Full indoor unit range is compatible with the CHU/CHQ Heating Only outdoor units.

125 Heating

126

127 Increasing energy bills, the need to reduce carbon emissions and the raft of challenging legislation are driving the demand for alternative forms of heating to improve energy efficiency. As a market leader in both commercial and domestic renewable solutions, Mitsubishi Electric is a pioneer in the development of heat pump technology. Heat pumps have been used around the world for decades and Mitsubishi Electric has refined this technology to produce Ecodan one of the most advanced, efficient heating systems available today. The award winning Ecodan heat pump range is suitable for both small and large projects and delivers effective, low carbon heating and hot water. Ecodan heat pumps provide a simple, renewable solution that rivals traditional heating systems. Helps achieve renewable energy targets Capable of reducing running costs and CO 2 emissions Easy to design, install and maintain Fully scalable and can work independently or in conjunction with other systems Optimised systems from kw to 90kW MCS approved From small flats to large detached houses, office blocks, schools and community heating schemes, Ecodan is the ideal choice to provide reliable space heating and hot water all year round. Certificate Number: MCS HP0002 Product Type: Heat Pumps Product Reference: PUHZWVHA2(BS), PUHZW85VHA2(BS) PUHZW112VHA(BS), PUHZHW10VHA2(BS)/YHA2(BS) QUHZW0VA, PUHZSWVKABS, PUHZSW75VHABS PUHZSW120VHABS, CAHVP0YAHPB MELCloud is a Cloud based solution for controlling your Mitsubishi Electric Ecodan systems either locally or remotely by PC, Mac, Tablet or Smartphone via the Internet. 2.1 Heating

128 Contents PUHZ(H)W Monobloc Standalone Air Source Heat Pumps QUHZW0VA / EHPT20QVM2EA Monobloc Air Source Heat Pump with Thermal Store CAHV Monobloc Air Source Heat Pump CRHV Monobloc Ground / Water Source Heat Pump EHPT20XMHCW FTC5 Packaged Cylinder for Ecodan Monobloc Units EHPT1517XUKHLCW FTC5 Preplumbed Slimline Cylinders for Ecodan Monobloc Units EHPT1XUKHCW FTC5 Preplumbed Standard Cylinders for Ecodan Monobloc Units EHPT210XUKHSCW FTC5 Preplumbed Solar Cylinders for Ecodan Monobloc Units EHPXVM2C FTC5 Packaged Hydrobo for Ecodan Monobloc Units PUHZSW Split Air Source Heat Pumps EHST20(D)(C)MHCW FTC5 Cylinders for Ecodan Split Units EHS(D)(C)MEC FTC5 Hydroboes for Ecodan Split Units FTC2B Flow Temperature Controller for use with Ecodan Monobloc Units and Third Party BEMS Energy Monitoring Packs Accessories / Optional Etras Heating

129 2. Heating PUHZ(H)W Monobloc Standalone Air Source Heat Pumps Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUTdOOR UnIT PUHZWVHA2(BS) PUHZW85VHA2(BS) PUHZW112VHA(BS) PUHZHW10YHA2(BS) HEAT PUMP SPACE HEATER 55 C HEAT PUMP SPACE HEATER 5 C HEAT PUMP COMBINATION HEATER Large Profile *1 HEATING *2 (A/W5) COP OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) ** LOW NOISE MODE (dba) * WATER DATA Pipework Size (mm) Flow Rate (l/min) Water Pressure Drop (kpa) DIMENSIONS (mm) *7 Width Depth Height WEIGHT (kg) ELECTRICAL DATA ErP Rating ɳ s SCOP ErP Rating ɳ s SCOP ErP Rating ɳ wh Capacity (kw) Power Input (kw) Electrical Supply Phase Nominal Running Current [MAX] (A) Fuse Rating MCB Sizes (A) * A++ 127%.25 A++ 12%.12 A 99% ~ +5 C * v, Hz 5. [1] 1 A++ 128%.27 A++ 12%.12 A 97% ~ +5 C * v, Hz 10. [2] 25 A++ 125%.20 A++ 1%.18 A 100% ~ +5 C * v, Hz 11.2 [29.5] 2 A++ 12%.22 A++ 157%.99 A 9% ~ +5 C * v, Hz 1.9 [5] 0 A++ 12%.22 A++ 157%.99 A 9% ~ +5 C * v, Hz 5.1 [1] 1 SYSTEM PRICES (BS Coastal models) 2,19 ( 2,209) 2,91 (,022),70 (,07),91 (,57),0 (,79) System price includes: Outdoor Unit, Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Fleible Connection Pipes, Flow Sensor & O Rings, DHW Cylinder Sensor, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. *1 Combination with EHPT20XMHCW Cylinder *2 Under normal heating conditions at outdoor temp: CDB / CWB, outlet water temp 5 C, inlet water temp 0 C. * Under normal heating conditions at outdoor temp: 7 CDB / CWB, outlet water temp 5 C, inlet water temp 0 C as tested to BS EN1511. * Sound power level of the PUHZWVHA2 is 1dBA, PUHZW85VHA2 is 2.5dBA, PUHZW112VHA is 5dBA, PUHZHW10VHA2 is 5.5dBA, PUHZHW10YHA2 is 7.5dBA. Tested to BS EN *5 Grille. * MCB Sizes BS EN08982 & BS EN0972. *7 Flow Temperature Controller (FTC) for standalone systems PACIF02BE Dimensions WDH (mm) 5201 ɳ s is the seasonal space heating energy efficiency (SSHEE) ɳ wh is the water heating energy efficiency

130 QUHZW0VA / EHPT20QVM2EA Monobloc Air Source Heat Pump With Thermal Store OUTdOOR UnIT QUHZW0VA THERMAL STORE EHPT20QVM2EA HEAT PUMP COMBINATION ErP Rating A+ NOMINAL THERMAL STORE WATER VOLUME (LITRES) 200 HEATER 55ºC ɳ s 117% WATER TEMPERATURE RANGE DHW Mode ( C) 070 C HEAT PUMP COMBINATION SCOP ErP Rating 2.90 A Space Heating Mode ( C) 2 C MECHANICAL ZONES DHW and 1 Heating Zone (2 Zone capability with rd party 2port valves) HEATER Large Profile *1 HEATING *2 ɳ wh COP Capacity (kw) 129%.00.2 OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) SOUND POWER LEVEL (dba) * 0 ~ +5 C (RH<80%) 0 0 WATER DATA Primary Pump Grundfos Solar PML (A/W55) Power Input (kw) 2.18 Sanitary Hot Water Pump Grundfos Solar PML COP 1.98 Connection Size (mm) Heating / DHW 22 / 22 OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) * 15 ~ +5 C Primary Epansion Vessel (Litres) Charge Pressure (MPa (Bar)) (1) SOUND POWER LEVEL (dba) * 5 WATER SAFETY DEVICES Pressure relief valve (Mpa (Bar)) 0. () 2 No. devices WATER DATA Pipework Size (mm) 15 Flow sensor (supplied) Min. flow 1. L/min Flow Rate (l/min) to 8 Manual reset thermostat 85 C DIMENSIONS (mm) Width 595 DISTANCE BETWEEN OUTDOOR Height Difference 5 Depth 80 UNIT AND THERMAL STORE Height 100 (M) DIMENSIONS (mm) Piping Length 15 WEIGHT EMPTY / FULL (kg) 77 / 28 DIMENSIONS Width Depth Height * *5 715 ELECTRICAL DATA Electrical Supply Phase Maimum Running Current (A) Fuse Rating MCB Sizes (A) * 22020v, Hz WEIGHT (kg) ELECTRICAL DATA 57 Powered from indoor unit OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver SYSTEM PRICE,225 System price includes: Outdoor Unit, Thermal Store, Fleible Connection Pipes, Magnetic & Cyclonic Filter, Epansion Vessel, Warranty Card, Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Thermal Store includes: Main Controller, Circulating Pumps, Magnetic & Cyclonic Filter, Flow Sensor and Epansion Vessel. *1 Combination with EHPT20QVM2EA Thermal Store. *2 Under normal heating conditions at outdoor temp: CDB / CWB, outlet water temp 55 C, inlet water temp 7 C. * Under normal heating conditions at outdoor temp: 7 CDB / CWB, outlet water temp 55 C, inlet water temp 7 C as tested to BS EN1511. * Sound power level tested to BS EN *5 Grille or pipe cover. * MCB Sizes BS EN08982 & BS EN0972. ɳ s is the seasonal space heating energy efficiency (SSHEE) ɳ wh is the water heating energy efficiency 2.5 Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

131 2. Heating CAHV Monobloc Air Source Heat Pump Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges OUTdOOR UnIT HEAT PUMP SPACE HEATER 55 C HEAT PUMP SPACE HEATER 5 C SCOP HEATING *1 Capacity (kw) (A/W5) Power Input (kw) COP OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) *2* LOW NOISE MODE (dba) *2 FLOW RATE(l/min) WATER PRESSURE DROP (kpa) DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE NOMINAL RUNNING CURRENT [MAX] (A) FUSE RATING MCB SIZES (A) * PRICE ErP Rating ɳ s SCOP ErP Rating ɳ s CAHVP0YAHPB A++ 125%.19 A+ 19% ~+0ºC 59 Variable (1 without legs) v, Hz 17. [52.9] 19,80 Price includes: Commissioning *1 Under normal heating conditions at outdoor temp: CDB / CWB, outlet water temp 5 C, inlet water temp 0 C *2 Under normal heating conditions at outdoor temp: 7 CDB / CWB, outlet water temp 5 C, inlet water temp 0 C as tested to BS EN1511 * Sound power level of the CAHVP0YAHPB is 70.7dBA. Tested to BS EN12102 * MCB Sizes BS EN08982 & BS EN0972 ɳ s is the seasonal space heating energy efficiency (SSHEE) ɳ wh is the water heating energy efficiency

132 CRHV Monobloc Ground / Water Source Heat Pump CRHV UnIT CRHVP00YAHPB HEAT PUMP SPACE HEATER 55 C ErP Rating A++ ɳ s 127% SCOP.7 HEAT PUMP SPACE HEATER 5 C ErP Rating A++ ɳ s 15% SCOP.0 HEATING *1 Capacity (kw) 0 (B0/W5) Power Input inc. pump (kw) 1.20 COP.2 SEASONAL EFFICIENCY EN1825 (SPF) B0/W5 (0kW). HEATING *2 Capacity (kw) 5 (B0/W5) Power Input inc. pump (kw) COP.1 SEASONAL EFFICIENCY EN1825 (SPF) B0/W5 (5kW).0 HEATING * Capacity (kw) 0 (W10/W5) Power Input inc. pump (kw) COP 5.08 SEASONAL EFFICIENCY EN1825 (SPF) W10/W5 (0kW) 5.09 HEATING * Capacity (kw) 5 (W10/W5) Power Input inc. pump (kw) 8.89 COP 5.11 SEASONAL EFFICIENCY EN1825 (SPF) W10/W5 (5kW).55 SOUND DATA Pressure Level LpA at 1m (dba) Power Level LwA (dba)*5 WATER DATA Flow Rate Range Heat Source (Brine) (l/s (m /hr)) 1.5 to.1 (5. to 15) Building Side (LTHW) (l/s (m /hr)) 1.5 to. (5. to 1) Mechanical Connections Heat Source Outlet (Brine) (mm (")).8 (R2) screw Heat Source Inlet (Brine) (mm (")).8 (R2) screw Building Side Outlet (LTHW) (mm (")).8 (R2) screw Building Side Inlet (LTHW) (mm (")).8 (R2) screw Operating Temperature Range Heat Source Inlet (Brine) ( C) 5 to +27 Heat Source Inlet Option (Brine) ( C)* 5 to +5 Building Side Outlet (LTHW) ( C) +0 to +5 Heat Source Fluid Type *7 Min 0% Ethylene Glycol or equivalent Pressure Drop Heat Source (Brine) (kpa) 12 (at 1.5l/s inc 0% glycol in heat source fluid) Building Side (LTHW) (kpa) 7 Maimum Working Pressure Heat Source (Brine) (MPa(Bar)) 1 (10) Building Side (LTHW) (MPa(Bar)) 1 (10) DIMENSIONS Width (mm) 9 Depth (mm) 780 Height (mm) 151 WEIGHT (kg) 95 REFRIGERANT Type R10A Charge (kg).5 2 Ma pressure (MPa (Bar)).15 (1.5) Compressor Type Inverter Driven Circuit type Hermetically Sealed System ELECTRICAL DATA Electrical Supply 15v, Hz Phase Phase Maimum Running Current (A) Fuse Rating MCB Size (A)*8 PRICE Price includes: Commissioning and two Y type strainers PLEASE NOTE: Full design criteria is needed to ascertain the capacity which could change based on heat source temperature and building flow temperature. ɳ s is the seasonal space heating energy efficiency (SSHEE) ɳ wh is the water heating energy efficiency *1 Under normal heating conditions at brine inlet: 0 C, outlet water temp 5 C as tested to BS EN1511 (0kW) *2 Under normal heating conditions at brine inlet: 0 C, outlet water temp 5 C as tested to BS EN1511 (5kW) * Under normal heating conditions at water inlet: 10 C, outlet water temp 5 C as tested to BS EN1511 (0kW) * Under normal heating conditions at water inlet: 10 C, outlet water temp 5 C as tested to BS EN1511 (5kW) *5 Sound power level as tested to BS EN12102 * Heat source inlet temperature above 27ºC and up to 5 C option must reverse the inlet and outlet heat source connections and refer to manual for dip switch changes *7 The system should be adequately protected from freezing *8 MCB Sizes BS EN08982 & BS EN ,29 * LTHW Low Temperature Hot Water * Please use adequate frost protection to ensure pipework and the unit do not freeze if the system is powered down * Please do not use ground water or well water directly within the unit * The water circuit must be a closed circuit 2.7 Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

133 2.8 Heating EHPT20XMHCW FTC5 Packaged Cylinder for Ecodan Monobloc Units Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges CYLIndER EHPT20XMHCW 200 ErP Rating A 0 ~ +5 C (RH<80%) 28 Flow Rate (l/min) W W85 W112 HW Primary Pump Grundfos UPM Sanitary Hot Water Pump Grundfos UPSO 1 10 CIL2 Connection Size (mm) Heating / DHW 28 / 22 Primary Epansion Vessel (Litres) 12 Charge Pressure (MPa (Bar)) 0.1 (1) Water Circuit Control Thermistor ( C) 1 80 Pressure Relief Valve (MPa (Bar)) 0. () Flow Sensor (minimum flow 5L/min) Supplied DHW Cylinder Control Thermistor ( C) 070 Temp and Pressure Relief Valve ( C)/ (MPa (Bar)) 90 / 0.7 (7) Width 595 Depth 80 Height / 07 Control Board Electrical Supply 22020v, Hz optionally powered Phase by outdoor unit Fuse Rating MCB Sizes (A) *1 10 Immersion Heater Electrical Supply 22020v, Hz Phase Capacity (kw) Ma Running Current (A) 1 Fuse Rating MCB Sizes (A) *1 1 MECHANICAL ZONES DHW and 1 Heating Zone *2 OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver NOMINAL HOT WATER VOLUME (LITRES) HEAT PUMP COMBINATION HEATER Large Profile (with PUHZW85VHA2) OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) WATER DATA WATER SAFETY DEVICES DIMENSIONS (mm) WEIGHT EMPTY / FULL (kg) ELECTRICAL DATA SYSTEM PRICES (BS Coastal models) PUHZWVHA2 PUHZW85VHA2 PUHZW112VHA PUHZHW10VHA2 PUHZHW10YHA2,81 (,91), (,7) 5,192 ( 5,29),11 (,295),2 (,518) System price includes: Outdoor Unit, Cylinder, Magnetic & Cyclonic Filter, G Compliance Kit, Fleible Connection Pipes, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Echanger, Scale Trap, kw Immersion Heater and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972 *2 Optional 2 zone accessory pack available

134 EHPT1517XUKHLCW FTC5 Preplumbed Slimline Cylinders for Ecodan Monobloc Units CYLIndER EHPT15XUKHLCW EHPT17XUKHLCW NOMINAL HOT WATER VOLUME (LITRES) ErP RATING C C HEAT LOSS (kwh/2hrs) HEAT LOSS (W) WATER Flow Rate (l/min) W W85 W Primary Pump 2 Grundfos UPS2 1 2 Grundfos UPS2 1 Sanitary Hot Water Pump Grundfos UPSO 1 CIL2 Grundfos UPSO 1 CIL2 Connection Size (mm) Heating / DHW (mm) Primary Epansion Vessel (Litres) Charge Pressure (MPa (Bar)) 0.5 (.5) 0.5 (.5) WATER SAFETY Water Circuit Control Thermistor ( C) DEVICES Pressure Relief Valve (MPa (Bar)) 0. () 0. () Epansion Relief Valve (Cold) 0.8 (8) 0.8 (8) DHW Cylinder Control Thermistor High Limit Stat ( C) Mechanical 80 Mechanical 80 Temp and Pressure Relief Valve ( C) / (MPa (Bar)) 90 / 1.0 (10) 90 / 1.0 (10) DIMENSIONS (mm) Width Depth Height WEIGHT EMPTY / FULL (kg) 5 / 20 0 / 20 CYLINDER MATERIAL Cylinder Cylinder Material Stainless Steel Stainless Steel Insulation Insulation Type CFC / HCFCfree flameretardant epanded Polyurethane Insulation Thickness (mm) Standing Heat Loss (kwh/2hrs) GWP of Insulation.1.1 ODP of Insulation 0 0 ELECTRICAL DATA Control Board Electrical Supply 22020v, Hz 22020v, Hz optionally powered by outdoor unit Immersion Heater SYSTEM PRICES (BS Coastal models) PUHZWVHA2,519 (,589),570 (,0) PUHZW85VHA2 PUHZW112VHA,29 (,02) N/A,5 (,5),901 ( 5,08) System price includes: Outdoor Unit, Cylinder, Fleible Connection Pipes, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Echanger, Scale Trap, kw Immersion Heater and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972 *2 Optional 2 zone accessory pack available Phase Fuse Rating MCB Sizes (A) * Electrical Supply 22020v, Hz 22020v, Hz Phase Capacity (kw) Ma Running Current (A) 1 1 Fuse Rating MCB Sizes (A) *1 1 1 MECHANICAL ZONES DHW and 1 Heating Zone *2 DHW and 1 Heating Zone *2 OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver 2.9 Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

135 2.10 Heating EHPT1XUKHCW FTC5 Preplumbed Standard Cylinders for Ecodan Monobloc Units CYLIndER EHPT15XUKHCW EHPT17XUKHCW EHPT21XUKHCW EHPT25XUKHCW EHPT0XUKHCW NOMINAL HOT WATER VOLUME (LITRES) ErP RATING HEAT LOSS (kwh/2hrs) HEAT LOSS (W) WATER SYSTEM PRICES (BS Coastal models) Flow Rate (l/min) W W85 W112 HW10 Primary Pump Sanitary Hot Water Pump Connection Size (mm) Heating / DHW (mm) Primary Epansion Vessel (Litres) Charge Pressure (MPa (Bar)) WATER SAFETY Water Circuit Control Thermistor ( C) DEVICES Pressure Relief Valve (MPa (Bar)) Epansion Relief Valve (Cold) DHW Cylinder Control Thermistor High Limit Stat ( C) Temp and Pressure Relief Valve ( C) / (MPa (Bar)) DIMENSIONS (mm) Width Depth Height WEIGHT EMPTY / FULL (kg) CYLINDER MATERIAL Cylinder Cylinder Material Insulation Insulation Type Insulation Thickness (mm) Standing Heat Loss (kwh/2hrs) GWP of Insulation ODP of Insulation ELECTRICAL DATA Control Board Electrical Supply optionally powered by outdoor unit Immersion Heater Phase Fuse Rating MCB Sizes (A) *1 Electrical Supply Phase Capacity (kw) Ma Running Current (A) Fuse Rating MCB Sizes (A) *1 MECHANICAL ZONES OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER 1 B (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 20 Stainless Steel v, Hz v, Hz 1 1 PUHZWVHA2,519 (,589),570 (,0) N/A N/A N/A PUHZW85VHA2,29 (,02),5 (,5),97 (,5) N/A N/A PUHZW112VHA N/A,901 ( 5,08),95 ( 5,090) 5,057 ( 5,19) 5,21 ( 5,) PUHZHW10VHA2 N/A N/A 5,87 (,05) 5,978 (,10),1 (,1) PUHZHW10YHA2 N/A N/A,087 (,279),191 (,8),7 (,59) System price includes: Outdoor Unit, Cylinder, Fleible Connection Pipes, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Echanger, Scale Trap, kw Immersion Heater and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972 *2 Optional 2 zone accessory pack available 170 B (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 22 Stainless Steel v, Hz v, Hz C Grundfos UPS2 2 Grundfos UPSO 1 CIL (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 279 Stainless Steel v, Hz v, Hz C (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 27 Stainless Steel CFC / HCFCfree flameretardant epanded Polyurethane Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges v, Hz v, Hz 1 1 DHW and 1 Heating Zone *2 PARWTE Controller and PARWR51E Receiver 00 C (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 87 Stainless Steel v, Hz v, Hz 1 1

136 EHPT210XUKHSCW FTC5 Preplumbed Solar Cylinders for Ecodan Monobloc Units CYLIndER EHPT21XUKHSCW EHPT25XUKHSCW EHPT0XUKHSCW NOMINAL HOT WATER VOLUME (LITRES) ErP RATING HEAT LOSS (kwh/2hrs) HEAT LOSS (W) WATER SYSTEM PRICES (BS Coastal models) Flow Rate (l/min) W W85 W112 HW10 Primary Pump Sanitary Hot Water Pump Connection Size (mm) Heating / DHW (mm) Primary Epansion Vessel (Litres) Charge Pressure (MPa (Bar)) WATER SAFETY Water Circuit Control Thermistor ( C) DEVICES Pressure Relief Valve (MPa (Bar)) Epansion Relief Valve (Cold) DHW Cylinder Control Thermistor High Limit Stat ( C) Temp and Pressure Relief Valve ( C) / (MPa (Bar)) DIMENSIONS (mm) Width Depth Height WEIGHT EMPTY / FULL (kg) CYLINDER MATERIAL Cylinder Cylinder Material Insulation Insulation Type Insulation Thickness (mm) Standing Heat Loss (kwh/2hrs) GWP of Insulation ODP of Insulation ELECTRICAL DATA Control Board Electrical Supply optionally powered by outdoor unit Immersion Heater Phase Fuse Rating MCB Sizes (A) *1 Electrical Supply Phase Capacity (kw) Ma Running Current (A) Fuse Rating MCB Sizes (A) *1 MECHANICAL ZONES OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PUHZWVHA2,778, (,88),882 (,952) N/A PUHZW85VHA2,55 (,1),57 (,75),81 (,921) PUHZW112VHA 5,109 ( 5,2) 5,21 ( 5,) 5,9 ( 5,) PUHZHW10VHA2 PUHZHW10YHA2,00 (,212),2 (,5),1 (,1),7 (,59),290 (,72), (,95) System price includes: Outdoor Unit, Cylinder, Fleible Connection Pipes, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Echanger, Scale Trap, kw Immersion Heater and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972 *2 Optional 2 zone accessory pack available 210 C (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 28 Stainless Steel v, Hz v, Hz C Grundfos UPS2 1 Grundfos UPSO 1 CIL (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 2 Stainless Steel CFC / HCFCfree flameretardant epanded Polyurethane v, Hz v, Hz 1 1 DHW and 1 Heating Zone *2 PARWTE Controller and PARWR51E Receiver 00 C (.5) () 0.8 (8) 070 Mechanical / 1.0 (10) / 92 Stainless Steel v, Hz v, Hz Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

137 2.12 Heating EHPXVM2C FTC5 Packaged Hydrobo for Ecodan Monobloc Units Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges HYdROBOX EHPXVM2C OPERATING AMBIENT TEMPERATURE ( C DB) 0 ~ +5 C (RH<80%) SOUND PRESSURE LEVEL AT 1M (dba) 28 WATER DATA Flow Rate (l/min) W W85 W112 HW Pump Grundfos UPM Connection Size (mm) 28 Primary Epansion Vessel (Litres) 10 Charge Pressure (MPa (Bar)) 0.1 (1) WATER SAFETY DEVICES Control Thermistor ( C) 1 80 Pressure Relief Valve (Mpa (Bar)) 0. () Flow Sensor (minimum flow 5L/min) Supplied Booster Heater Control Thermistor ( C) 80 Booster Heater Manual Reset Thermostat ( C) 90 Booster Heater Thermal Cut Off ( C) 121 DIMENSIONS (mm) Width Depth 0 Height 800 WEIGHT EMPTY / FULL (kg) 7 / 2 ELECTRICAL DATA Control Board Electrical Supply 22020v, Hz optionally powered Phase by outdoor unit Fuse Rating MCB Sizes (A) *1 10 Booster Heater Electrical Supply 22020v, Hz optionally powered Phase if required Capacity (kw) 2 Ma Running Current (A) 9 Fuse Rating MCB Sizes (A) *1 1 OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver SYSTEM PRICES (BS Coastal models) PUHZWVHA2 PUHZW85VHA2 PUHZW112VHA PUHZHW10VHA2 PUHZHW10YHA2 2,82 ( 2,912),17 (,725),17 (,09) 5,09 ( 5,27) 5,07 ( 5,99) System price includes: Outdoor Unit, Hydrobo, Fleible Connection Pipes, Magnetic & Cyclonic Filter, DHW Cylinder Sensor, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Hydrobo includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Water Circulation Pump, Flow Sensor and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972

138 PUHZSW Ecodan Split Air Source Heat Pumps OUTdOOR UnIT PUHZSWVKABS PUHZSW75VHABS PUHZSW120VHABS HEAT PUMP SPACE HEATER 55 C HEAT PUMP SPACE HEATER 5 C HEAT PUMP COMBINATION HEATER Large Profile *1 HEATING *2 (A/W5) OPERATING AMBIENT TEMPERATURE ( C DB) *7 * * SOUND PRESSURE LEVEL AT 1M (dba LOW NOISE MODE (dba) * WATER DATA Water connections made at indoor hydrobo DIMENSIONS (mm) WEIGHT (kg) REFRIGERANT ELECTRICAL DATA SYSTEM PRICES please refer to sections 2.1 and 2.1 ErP Rating ɳ s SCOP ErP Rating ɳ s SCOP ErP Rating ɳ wh Capacity (kw) Power Input (kw) COP Flow Rate (l/min) Width Depth Height Type Charge (kg) 10m pipe length Pipe Size Gas/Liquid (mm (in)) Connection Type Ma Pipe Length (m) Min Pipe Length (m) Ma Height Difference (m) Electrical Supply Phase Nominal Running Current [MAX] (A) Fuse Rating MCB Sizes (A) * A++ 125%.20 A++ 1%.1 A 98% ~ +5 C * R10A (1/2") /.5 (1/") Flared v, Hz.8 [1] 1 A++ 127%.2 A++ 15%.92 A 9% ~ +5 C * R10A (5/8") / 9.52 (/8") Flared v, Hz 8.1 [19] 25 A++ 125%.21 A++ 12%.1 A 99% ~ +5 C * R10A (5/8") / 9.52 (/8") Flared v, Hz 17.5 [29.5] 0 *1 Combination with EHST20(D)(C)MHCW Cylinders *2 Under normal heating conditions at outdoor temp: CDB / CWB, outlet water temp 5 C, inlet water temp 0 C * Under normal heating conditions at outdoor temp: 7 CDB / CWB, outlet water temp 5 C, inlet water temp 0 C as tested to BS EN1511 * Sound power level of the PUHZSWVKA is 2dBA, PUHZSW75VHA2 is 5.dBA, PUHZSW120VHA is 8.8dBA. as tested to BS EN12102 *5 Grille * MCB Sizes BS EN08982 & BS EN0972 *7 Heating maimum ambient temperature ~21 CDB, DHW Hot water maimum ambient temperature ~5 CDB *8 Electrical cover ɳ s is the seasonal space heating energy efficiency (SSHEE) ɳ wh is the water heating energy efficiency 2.1 Heating

139 2.1 Heating EHST20(d)(C)MHCW FTC5 Cylinders for Ecodan Split Units Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges CYLIndER EHST20dMHCW EHST20CMHCW NOMINAL HOT WATER VOLUME (LITRES) APPLICABLE OUTDOOR UNIT HEAT PUMP SPACE HEATER 55 C HEAT PUMP SPACE HEATER 5 C HEAT PUMP COMBINATION HEATER Large Profile OPERATING AMBIENT TEMPERATURE ( C DB) SOUND PRESSURE LEVEL AT 1M (dba) WATER DATA WATER SAFETY DEVICES DIMENSIONS (mm) WEIGHT EMPTY / FULL (kg) REFRIGERANT ELECTRICAL DATA Water Circuit DHW Cylinder Control Board optionally powered by outdoor unit Immersion Heater ErP Rating ErP Rating ErP Rating Flow Rate (l/min) Primary Pump Sanitary Hot Water Pump Connection Size (mm) Heating / DHW Primary Epansion Vessel (Litres) Charge Pressure (MPa (Bar)) Control Thermistor ( C) Pressure Relief Valve (MPa (Bar)) Flow Sensor (minimum flow 5L/min) Control Thermistor ( C) Temp and Pressure Relief Valve ( C)/ (MPa (Bar)) Width Depth Height Type Connection Size Gas Liquid (mm)(in) Connection Type Electrical Supply Phase Fuse Rating MCB Sizes (A) *1 Electrical Supply Phase Capacity (kw) Ma Running Current (A) Fuse Rating MCB Sizes (A) *1 200 PUHZSWVKABS A++ A++ A 0 ~ +5 C (RH<80%) (SW) Grundfos UPM Grundfos UPSO 1 10 CIL2 28 / (1) () Supplied / 0.7 (7) / 12 R10A 12.7 (1/2") /.5 (1/") Flared 22020v, Hz v, Hz 1 1 DHW and 1 Heating Zone*2 200 PUHZSW75VHABS / PUHZSW120VHABS A++ /A++ A++ /A++ A / A 0 ~ +5 C (RH<80%) (SW75) / 5.9 (SW120) Grundfos UPM Grundfos UPSO 1 10 CIL2 28 / (1) () Supplied / 0.7 (7) / 20 R10A (5/8") / 9.52 (/8") Flared 22020v, Hz v, Hz 1 1 MECHANICAL ZONES DHW and 1 Heating Zone *2 OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver SYSTEM PRICES PUHZSWVKA PUHZSW75VHA PUHZSW120VHA,07 N/A N/A N/A,1 5,588 System price includes: Outdoor Unit, Cylinder, Magnetic & Cyclonic Filter, G Compliance Kit, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Echanger, Scale Trap, kw Immersion Heater and Epansion Vessel. *1 MCB Sizes BS EN08982 & BS EN0972 *2 Optional 2 zone accessory pack available

140 EHS(d)(C)MEC FTC5 Hydroboes for Ecodan Split Units HYdROBOX EHSdMEC EHSCMEC HEAT PUMP SPACE HEATER 55 C HEAT PUMP SPACE HEATER 5 C OPERATING AMBIENT TEMPERATURE ( C DB) APPLICABLE OUTDOOR UNITS SOUND PRESSURE LEVEL AT 1M (dba) WATER DATA WATER SAFETY DEVICES DIMENSIONS (mm) WEIGHT EMPTY / FULL (kg) REFRIGERANT ELECTRICAL DATA Control Board optionally powered by outdoor unit ErP Rating ErP Rating Flow Rate (l/min) Pump Connection Size (mm) Charge Pressure (MPa (Bar)) Control Thermistor ( C) Pressure Relief Valve (MPa (Bar)) Flow Switch Width Depth Height Type Connection Size Gas/Liquid (mm (in) Connection Type Electrical Supply Phase Fuse Rating MCB Sizes (A) *1 A++ A++ 0 ~ +5 C (RH<80%) PUHZSWVKABS (SW) Grundfos UPM (1) () Supplied / R10A 12.7 (1/2") /.5 (1/") Flared 22020v, Hz 10 OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PARWTE Controller and PARWR51E Receiver A++ / A++ A++ / A++ 0 ~ +5 C (RH<80%) PUHZSW75VHABS / PUHZSW120VHABS (SW75) / 5.9 (SW120) Grundfos UPM (1) () Supplied / 9 R10A (5/8") / 9.52 (/8") Flared 22020v, Hz 10 SYSTEM PRICES PUHZSWVKA PUHZSW75VHA PUHZSW120VHA 2,77 N/A N/A N/A,1,20 System price includes: Outdoor Unit, Hydrobo, Magnetic & Cyclonic Filter, DHW Cylinder Sensor, Warranty Card, Ecodan Homeowner DVD, FTC5 Homeowner Quick Start Guide, Ecodan Commissioning Document and MCS Commissioning Label. Hydrobo includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Water Circulation Pump and Flow Sensor. *1 MCB Sizes BS EN08982 & BS EN Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

141 2.1 Heating FTC2B Flow Temperature Controller For use with Ecodan Monobloc Units and Third Party BEMS Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges FTC2B DIMENSIONS (mm) Width Depth Height WEIGHT (kg) OPERATING AMBIENT TEMPERATURE ( C DB) ELECTRICAL DATA Electrical Supply Phase PACIF02BE ~+5ºC (RH<80%) Powered from outdoor unit (20v) SYSTEM PRICES (BS Coastal models) PUHZWVHA2 PUHZW85VHA2 PUHZW112VHA PUHZHW10VHA2 PUHZHW10YHA2 1,929 ( 1,999) 2,70 ( 2,812),258 (,95),181 (,),9 (,58) System price includes: Outdoor Unit, Flow Temperature Controller (FTC2B) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Ecodan Commissioning Document and Fleible Connection Pipes.

142 Energy Monitoring Packs ENERgy MONiTORiNg PACK ONE (EMP1) EMP1 is inbuilt energy monitoring and is included with every Flow Temperature Control 5 (FTC5) system free of charge. The system displays consumed and produced energy to the nearest kwh. Optional WiFi interface for use with MELCloud (PACWF010E) PRICE 72 ENERgy MONiTORiNg PACK TWO (EMP2) EMP2 increases energy consumption accuracy and includes two Measuring Instrument Directive approved electric meters. EMP2 interfaces with FTC5 and records and measures to 1 pulse per watt hour, ensuring accurate energy consumption figures. Optional WiFi interface for use with MELCloud (PACWF010E) PRICE ENERgy MONiTORiNg PACK THREEMONOBLOC (EMPM) MMSP COMPLiANT EMPM for Ecodan monobloc systems contains the two electric meters from EMP2, a Measuring Instrument Directive approved heat meter with resolution to 1 Wh, a MELCloud WiFi interface and 1 years rolling data storage. This pack complies to the DECC metering and monitoring service pack criteria required for the additional domestic RHI payments. PRICE 97 ENERgy MONiTORiNg PACK THREEMONOBLOC (EMPMph) MMSP COMPLiANT EMPMph for Ecodan monobloc systems contains the two electric meters (1 single phase and 1 phase electric meters), a Measuring Instrument Directive approved heat meter with resolution to 1 Wh, a MELCloud WiFi interface and 1 years rolling data storage. This pack complies to the DECC metering and monitoring service pack criteria required for the additional domestic RHI payments. PRICE Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

143 2.18 Heating Energy Monitoring Packs Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges ENERgy MONiTORiNg PACK THREESPLiT (EMPS) MMSP COMPLiANT EMPS for Ecodan split systems contains the two electric meters from EMP2, a Measuring Instrument Directive approved heat meter with resolution to 1 Wh, a MELCloud WiFi interface and 1 years rolling data storage. This pack complies to the DECC metering and monitoring service pack criteria required for the additional domestic RHI payments. PRICE 97 ENERgy MONiTORiNg PACK HyBRiDMONOBLOC (EMPHM) EMPHM for Ecodan monobloc systems includes a Measuring Instrument Directive approved heat meter with resolution to 1 kwh that is required for hybrid systems claiming domestic RHI. phase electric meter / phase electric meter Optional WiFi interface for use with MELCloud (PACWF010E) PRICE 19 / ENERgy MONiTORiNg PACK HyBRiDSPLiT (EMPHS) EMPHS for split systems includes a Measuring Instrument Directive approved heat meter with resolution to 1 kwh that is required for hybrid systems claiming domestic RHI. phase electric meter / phase electric meter Optional WiFi interface for use with MELCloud (PACWF010E) PRICE 19 / 11 72

144 Ecodan Accessories / Optional Etras DESCRiPTiON MOdEL REF. PRICE PUHZ / QUHZ Accessories Remote Sensor A Wired Thermistor available for Room Temperature Monitoring Drain Socket Set Wireless Remote Controller Transmitter Wireless Remote Controller Receiver A wireless receiver should be purchased with a wireless transmitter. Up to 8 transmitters can be paired with 1 wireless receiver Remote Controller Blanking Plate Standard Sensor for optional 2Zone Control on Standalone Systems (PUHZ) High Temperature Sensor (PUHZ) DHW Cylinder Sensor (PUHZ) 2 Zone Pack 1 suitable for 2 zone applications where the temperature of both zones is the same. Pack contains 1 1 pump and isolation valves. 2 Zone Pack 2 suitable for 2 zone applications where the temperature of each zone is different. Pack contains 1 1 pump, isolation valves, miing valve / actuator and standard flow and return sensors for each zone (PUHZ) Fiit foot 00 kit Ferno HP5C Antifreeze containing biocide 10ltr Ferno HP5C Antifreeze containing biocide 25ltr wire adapter for low noise mode (PUHZ) MELCloud WiFi Interface TF1 Magnetic Particle Filter 22mm PUHZW85VHA2 / PUHZSW75VKA/VHA / QUHZW0VA TF1 Magnetic Particle Filter 28mm PUHZ(H)W11210VHA(2)/YHA2 / PUHZSW120VHA Fleible Connection Pipes (PUHZ) Fleible Connection Pipes (QUHZ) CAHV Accessories Main Pipework Thermistor Differential Pressure Switch for Water Systems Wired Remote Controller Centralised Controller AE200E Back Bo for wall recessed mounting AE200E Wall Mounted Bo for wall mounting PACSE1TSE PACSH71dSE PARWTRE PARWR51RE PACRC01 PACTH011E PACTH011HTE PACTH011TKE 2ZOnEP1 2ZOnEP2 PACWF010E TWTH1 KS10EP100S PARW21MAAJ AE200E PACYG8UTB PACYG82TB a pair ,717 9 CRHV Accessories Main Pipework Thermistor Wired Remote Controller Eternal Temperature Sensor and Solar Guard Differential Pressure Switch for Water Systems TWTH1 PARW21MAAJ TMPO KS10EP100S Heating Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

145 Ventilation

146

147 Fresh Air Ventilation Range Why Do We Need Fresh Air Ventilation? Poor indoor air quality can be attributed to many problems inside a building. Ecess humidity causes dampness, rot and mould, whilst pollutants are known to be a major cause of damaging health issues such as asthma and eczema. Stale air is also believed to lead to a loss in productivity and low morale. As the demand for improved energy efficiency results in increasingly airtight buildings, natural ventilation proves less effective and drives the need for mechanical ventilation. With increasing legislation, the challenge for designers, installers and occupiers of any building is to find ventilation that s both effective and energy efficient. Mitsubishi Electric meets this need with a range of ventilation products covering mechanical ventilation with heat recovery units (MVHR). These systems have been designed to deliver a fresh air supply to a building whilst simultaneously etracting stale air in the most energy efficient manner possible by utilising heat recovery technology. Benefits include: Clean, fresh air Improved air quality and comfort Increased climate control Energy efficient heat recovery Reduced energy bills.1 Ventilation

148 Fresh Air Ventilation Range Contents Lossnay VL100(E)U 5 E Wall Mounted Model Lossnay VL220CZGVEB Residential / Light Commercial Model Lossnay LGHRVXE Commercial Series Lossnay LGHRVXTE Commercial Series Lossnay Accessories Ventilation

149 . Ventilation VL100(E)U 5 E Wall Mounted Model Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges WALL MOUNTED VL100U 5 E VL100EU 5 E ElECtRICal POWER SuPPly 22020V, Hz 22020V, Hz PHaSE POWER CONSuMPtION (W) Low High airflow (m /h) Low 1 1 High SOuNd PRESSuRE level (dba) Low High 8 8 temperature EXCHaNGE EFFICIENCy (%) Low High WEIGHt (kg) dimensions (mm) Width Depth Height duct SIZE (mm) 2 Ø75 2 Ø75 FuSE RatING (BS88) HRC (a) MaINS CaBlE No. Cores CONtROl ON/OFF Pull Cord VFC for Eternal Wall Switch (Field Supply) PRICE

150 VL220CZGVEB Residential / Light Commercial Model MODEL VL220CZGVEB ElECtRICal POWER SuPPly 22020V/Hz WEIGHt (kg) 2 FaN SPEEd 1 2 RuNNING CuRRENt (a) INPut POWER (W) airflow (m /h) airflow (l/s) 18 1 EXtERNal StatIC PRESSuRE (Pa) temperature EXCHaNGE EFFICIENCy (%) NOISE (db) dimensions (mm) Width 8 Depth 720 Height 0 MaXIMuM CuRRENt (a) 0.8 PRICE 99 Price includes: VL220CZGVEB and P1DUE bypass damper..5 Ventilation Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

151 . Ventilation LGHRVXE Commercial Series Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges COMMERCIAL MODELS ElECtRICal POWER SuPPly RuNNING CuRRENt (a) SP1 SP2 SP SP INPut POWER (W) SP1 SP2 SP SP airflow (m /h) *2 SP1 SP2 SP SP airflow (l/s) *2 SP1 SP2 SP SP SPECIFIC FaN POWER (W/(l/s)) SP1 SP2 SP SP EXtERNal StatIC SP1 PRESSuRE (Pa) SP2 SP SP SOuNd PRESSuRE SP1 level (dba) SP2 SP SP temperature EXCHaNGE SP1 EFFICIENCy (%) SP2 SP SP ENtHalPy Heating SP1 EXCHaNGE SP2 EFFICIENCy SP (%) SP Cooling SP1 SP2 SP SP WEIGHt (kg) dimensions (mm) Width Depth Height duct SIZE (mm) StaNdaRd FIltER *1 FuSE RatING (BS88) HRC (a) LGH15RVXE 22020V, Hz EuG LGH25RVXE 22020V, Hz EuG LGH5RVXE 22020V, Hz EuG LGHRVXE 22020V, Hz EuG LGH5RVXE 22020V, Hz EuG LGH80RVXE 22020V, Hz EuG LGH100RVXE 22020V, Hz EuG LGH1RVXE LGH200RVXE 22020V, Hz (Sa,Ra)2 (Oa,Ea) EuG V, Hz (Sa,Ra)2 (Oa,Ea) EuG 10 PRICE ,1 1,1 1,528 2,25 2,999 Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 20v, Hz. Sound Pressure Level measured at 1.5m under the centre of panel. *1: EUF7 filter available as optional parts. *2: Airflow tested to Japan industrial standard JIS B 828. SP1, SP2, SP & SP relate to the fan speeds of the Lossnay RVX units i.e. fanspeed 1, 2, &.

152 LGHRVXTE Commercial Series COMMERCIAL MODELS LGH1RVXTE LGH200RVXTE LGH2RVXTE ElECtRICal POWER SuPPly RuNNING CuRRENt (a) INPut POWER (W) airflow (m /h) *2 airflow (l/s) *2 SPECIFIC FaN POWER (W/(l/s)) EXtERNal StatIC PRESSuRE (Pa) SOuNd PRESSuRE level (dba) temperature EXCHaNGE EFFICIENCy (%) SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP SP1 SP2 SP SP ENtHalPy Heating SP1 EXCHaNGE SP2 EFFICIENCy SP (%) SP Cooling SP1 SP2 SP SP WEIGHt (kg) dimensions (mm) Width Depth Height duct SIZE (mm) StaNdaRd FIltER *1 FuSE RatING (BS88) HRC (a) 22020V, Hz EuG V, Hz EuG V, Hz EuG 10 PRICE 2,81,12,1 Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 20v, Hz. Sound Pressure Level measured at 1.5m under the centre of panel. *1:M medium efficiency filter and F8 high efficiency filter available as optional parts. *2: Airflow tested to Japan industrial standard JIS B 828. SP1, SP2, SP & SP relate to the fan speeds of the Lossnay RVXT units i.e. fanspeed 1, 2, &..7 Ventilation Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

153 .8 Ventilation Lossnay Accessories Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges DESCRIPTION MODEL REF. PRICE Remote Controllers lossnay Remote Controller for lghrvx(t)e and Vl220CZGVEB lossnay Simplified Remote Controller for Vl220CZGVEB PZ1DRE PZSMFE 8 8 Medium Efficiency Filters Medium Efficiency Filter for Vl220CZGVEB Medium Efficiency Filter for lghrvxte P220EMFE PZMRTFME 92 High Efficiency Filters High Efficiency Filter for Vl100(E)u 5 E High Efficiency Filter for Vl220CZGVEB High Efficiency Filter for lgh15rvxe High Efficiency Filter for lgh25rvxe High Efficiency Filter for lgh5rvxe High Efficiency Filter for lghrvxe High Efficiency Filter for lgh5rvxe High Efficiency Filter for lgh80rvxe / lgh1rvxe (2 sets) High Efficiency Filter for lgh100rvxe / lgh200rvxe (2 sets) High Efficiency Filter for lghrvxte P100HF 5 E P220SHFE PZ15RFME PZ25RFME PZ5RFME PZRFME PZ5RFME PZ80RFME PZ100RFME PZF8RTFME Etension Pipe Kit Etension Pipe for Vl100(E)u 5 E Etension Pipe joint for Vl100(E)u 5 E P100PE P100PJE Weather Proof Housings lossnay weather proof housings are also available POA

154 Controls

155

156 The Importance of Controls The need for control is paramount in order to optimise the performance of any air conditioning, heating or ventilation system and minimise its running costs and the emissions generated. Mitsubishi Electric offer a wide range of control options designed to do just this. Operating an air conditioning, heating or ventilation system without the right control can prove costly. It s therefore important to ensure that every system is correctly specified and integrated within the building to the degree of control it requires. Mitsubishi Electric have a wide range of controls available offtheshelf and where needed, individual control systems can be specifically designed to suit. Good controls will benefit any application, large or small. Our range of products need to react to a variety of factors: different room sizes, usage and customer levels, changes in the climate, electronic equipment and lighting etc. The ability to monitor the energy consumption and operation of systems is also vital. It is often said that you cannot manage what you are not measuring. Our control systems will enable simple measuring and monitoring of energy consumption and running costs to ensure operation is maintained. So whatever the application, optimum control of our systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient. A Degree of Difference When an air conditioning, heating or ventilation system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure our products work as intended, whilst giving the optimum amount of control..1 Controls

157 The Importance of Controls Contents Remote Controllers Interfaces Centralised Controllers BEMS Interfaces Solution Interfaces Controls

158 . Controls Remote Controllers Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges REMOTE CONTROLLERS PACYT52CRA PACYT52CRAS PARU02MEDA PAR2MAA PARFL2MA PARFA2MA Description Simplified Remote Controller Silver Simplified Remote Controller Touch Remote Controller Standard Remote Controller Infrared Remote Controller Infrared Receiver Connect to Indoor Indoor MNET Network Indoor Indoor Ma Number of Units Compatibility Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Backlight Setpoint Limitation Independent Vane Control Contact Number under Fault Condition Scheduling Night Set Back Button Lock Easy Maintenance with Mr Slim Run / Standby with Mr Slim Silent Mode with Mr Slim Energy Saving with Mr Slim Occupancy Sensor (PIR) PRICE 1 Mr Slim, City Multi and M Series via MAC97IF *1 *1 111 Notes: *1 Permit/Prohibit is via Centralised Controllers. = Yes, = No, = Not applicable. 1 Mr Slim, City Multi and M Series via MAC97IF *1 * City Multi (M Series and Mr Slim via A2M adapter) (0.5 C) (0.5 C) (0.5 C) Weekly 1 Mr Slim, City Multi and M Series via MAC97IF (0.5 C) (0.5 C) (0.5 C) Weekly Mr Slim, City Multi and M Series via MAC97IF Mr Slim, City Multi and M Series via MAC97IF LED 58

159 Remote Controllers REMOTE CONTROLLERS AE200EWEB USER PZ1DRE PZSMFE PARW21MAA PARWTRE PARWR51RE PACIF02BE Description PC Remote Controller Lossnay Remote Controller Lossnay Simplified Remote Controller Standard Remote Controller Wireless Remote Controller Transmitter Wireless Remote Controller Receiver Flow Temperature Controller 5 Connect to AE200E and EWE Indoor Indoor PWFY, Mr Slim Air Curtains, Ecodan CAHV / CRHV FTC5 Ecodan PUHZ Ma Number of Units Compatibility 200 AE200E and EWE Lossnay LGHRVX(T)E Lossnay VL220CZGVEB City Multi PWFY Ecodan PUHZ Ecodan PUHZ Ecodan PUHZ Mr Slim Air Curtains Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Backlight Setpoint Limitation Independent Vane Control Contact Number under Fault Condition Scheduling Night Set Back Button Lock Easy Maintenance with Mr Slim Run / Standby with Mr Slim Silent Mode with Mr Slim Energy Saving with Mr Slim Occupancy Sensor (PIR) Weekly Weekly Weekly Weekly PRICE Notes: *1 Permit/Prohibit is via Centralised Controllers = Yes, = No, = Not applicable Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

160 . Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Interfaces INTERFACES PACSA89TA PACSA89TA PACCN2WHMC PACSA88HA PACSA88HA PACSA88HA PACYT51HAA PACYG10HA PACSJ19MA *2 PACSF8MA *2 Description Connect to On/Off Adapter ( wire adapter) Indoor Night Mode and Demand Control ( wire adapter) Outdoor Pulse Energy Meter Input Outdoor Run and Fault Adapter (5 wire adapter) Indoor Heat and Cool Adapter (5 wire adapter) Indoor Run and Fault Adapter (5 wire adapter) Outdoor On/Off Run and Fault Adapter ATB On/Off Run and Fault Adapter (9 wire adapter) AE200E and EWE MNET Converter Outdoor Ma Number of Units Compatibility Mr Slim and City Multi Mr Slim and City Multi City Multi Mr Slim and City Multi City Multi City Multi ATB AE200E and EWE Mr Slim Outdoor Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Fire Alarm On/Off but Centrally Controlled On/Off but NOT Centrally Controlled Run and Fault Output Heat and Cool Output Night Mode and Demand Control Connect Mr Slim to MNET VFC VFC 12VDC 12VDC 12VDC VFC Via 2VDC Via 2VDC Via 2VDC *1 PRICE Notes: VFC: Volt free contact. *1 PUHZ(ZR)P outdoor type only unit. *2 PACSJ19MA compatible with PUHZZRP5. PACSF8MA compatible with all other PUHZ(ZR)P. = Yes, = No, = Not applicable.

161 Interfaces INTERFACES TCB1 IO INTERFACE PACYG0MCA PACYGMCA PACYGDCA Description On/Off Adapter Input / Output Interface Pulse Meter Interface Temperature Interface Third Party Interface Connect to Indoor Indoor MNET Network MNET Network MNET Network Ma Number of Units 1 1 Pulse Meters 1 PT100, 1 Humidity Sensor 2 General Equipment Compatibility Mr Slim and City Multi M Series and Mr Slim AE200E and EWE AE200E and EWE AE200E and EWE Power Supply Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature On/Off but Centrally Controlled On/Off but NOT Centrally Controlled Run Output Fault Output Energy Saving Heat / Cool / Thermo Output Pulse Weight PRICE Notes: VFC: Volt free contact. = Yes, = No, = Not applicable. 12VDC VDC VFC 0 to 10VDC 0 to 10VDC 0 to 10VDC VFC VFC VFC VFC VFC VFC VFC VFC VFC VFC 2VDC , 1.0 and 10 2VDC VDC Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

162 .8 Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges Interfaces INTERFACES MAC97IF MACIF MAC557IF PACWF010 Description M Series Adapter Adapter and MNET Converter for M Series WiFi Interface WiFi Interface Connect to Indoor Indoor Indoor Indoor Ma Number of Units Compatibility M Series and Mr Slim M Series and Mr Slim M Series and Mr Slim Ecodan FTC5 Power Supply Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature On/Off but Centrally Controlled On/Off but NOT Centrally Controlled Run Output Fault Output Energy Saving Heat / Cool / Thermo Output Pulse Weight PRICE Notes: VFC: Volt free contact. = Yes, = No, = Not applicable.

163 Centralised Controllers CENTRALISED CONTROLLERS ATB AE200E PACYG82TB PACYG8UTB Description 5 Touch Screen Controller 10. Touch Screen Controller AE200E Wall Mounted Bo AE200E Back Bo Connect to MNET Network MNET Network Ma Number of Units and Pulse Meters Compatibility Power Supply Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Weekly Schedule Annual Schedule Night Set Back Web Pages Optimised Start Automatic Setpoint Adjustment Load Shedding Occupied / Unoccupied Settings Reset Remote Monitoring with M2M Simple Energy Monitoring Advanced Energy Monitoring M Series, Mr Slim and City Multi Via PACSC51KUA * M Series, Mr Slim, City Multi, Lossnay and Ecodan CAHV 22020v, Hz AE200E AE200E PRICE 8 1,717 9 Notes: AE200E demonstration website: AE200E PIN CODES: AE200EENERGY 75 AE200EBACNET 900 AE200EWEB USER 10.9 Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

164 .10 Controls Centralised Controllers CENTRALISED CONTROLLERS EWE PACSC51KUA Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges PACSFEPA Description Web Interface and AE200E epansion controller MNET Power Supply MNET Booster Connect to MNET Network MNET Network MNET Network Ma Number of Units and Pulse Meters Compatibility M Series, Mr Slim and City Multi ATB, EWE and AE200E M Series, Mr Slim and City Multi Power Supply Dimensions (mm) (WDH) Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Weekly Schedule Annual Schedule Night Set Back Web Pages Optimised Start Automatic Setpoint Adjustment Load Shedding Occupied / Unoccupied Settings Reset Remote Monitoring with M2M Simple Energy Monitoring Advanced Energy Monitoring PRICE Notes: The EWE epansion controller cannot be used with BEMS interfaces v, Hz , v, Hz v, Hz

165 BEMS Interfaces BEMS INTERFACES MELCOBEMS MINI BACHD1 Description Connect to Ma Number of Units Compatibility Power Supply Air to Air Splits Modbus/BACnet Interface. Air (Water) to Water Modbus Interface Indoor 1 M Series, Mr Slim, Ecodan FTC/5, CAHV, CRHV MNET BACnet Interface MNET M Series, Mr Slim and City Multi 22020v, Hz Dimensions (mm) (WDH) Network Modbus / BACnet RS85 BACnet TCP/IP BEMS Compatibility Cylon, Satchwell, Crestron, Invensys, Interactive Homes, North BT, Andover, Siemens, WEMS, RDM Andover Controls, York BMS, Siemens, Priva Building Intelligence, Delta Controls Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Air to Air Splits DI AI AI AI AI DI Air (Water) to Water AI AI AI AI DI AI AI AI AI DI DI Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Daily kw Energy Monthly kw Energy DO AO AO AO AO DO AO AO DO AO AO AO AO AO AO AO DO AO AO AO AO DO DO AO AO PRICE Key: DI = Digital Input. DO = Digital Output. AI = Analogue Input. AO = Analogue Output. Note: The EWE epansion controller cannot be used with BEMS interfaces ,89.11 Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

166 .12 Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges BEMS Interfaces BEMS INTERFACES MELCOBEMS LMAP0 IQ XNC Description AE200E Modbus BACnet Interface MNET LonWorks Interface AE200E Trend Interface Connect to AE200E and EWE MNET AE200E and EWE Ma Number of Units Compatibility M Series, Mr Slim and City Multi M Series, Mr Slim and City Multi M Series, Mr Slim and City Multi Power Supply Dimensions (mm) (WDH) Network 2VDC Modbus / BACnet RS85 and TCP/IP 22020v, Hz LonWorks FTT10A 22020v, Hz 2 1 Trend BEMS Compatibility Cylon, Satchwell, Crestron, Invensys, Interactive Homes, North BT, Andover, Siemens, WEMS, Andover Controls, York BMS, Siemens, Priva Building Intelligence, Delta Controls, RDM Honeywell, Johnson Controls, Realtime Control Systems, Smart Controls Trend Control Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Daily kw Energy Monthly kw Energy DI AI AI AI AI DI DI DO AO AO AO AO DO DO AO AO With EWE *1 With EWE *1 DI AI AI AI AI DI DI DO AO AO AO AO DO DO AO AO DI AI AI AI AI DI DI DO AO AO AO AO DO DO AO AO PRICE 1,8 1,155 From Synapsys *2 Key: DI = Digital Input. DO = Digital Output. AI = Analogue Input. AO = Analogue Output. Note: The PACYG***CA are not compatible with MELCOBEMS, LMAP0 and IQ XNC. The EWE epansion controller cannot be used with BEMS interfaces. *1 The MELCOBEMS can monitor indoor daily and monthly kwh when used in conjunction with AE200E, EWE, PACYG0MCA on third party energy meters. *2 Synapsys Solutions Ltd, 1 Woodlands Court, Albert Drive, Burgess Hill, West Susse, RH15 9TN, Telephone

167 Solution Interfaces SOLUTION INTERFACES PANEL _RS_SMS MELCOTEL2 MELCORETAIL MELCORETAIL2G RMI PACKAGE LAN/ADSL RMI PACKAGE G Description Run Standby Panel AE200E Hotel MELCORETAIL MELCORETAIL 2G Remote Control & Remote Control & Interface and display Monitoring Interface Monitoring Interface Connect to MELCOBEMS MINI AE200E and EWE MELCOBEMS MINI AE200E / EWE MELCOBEMS MINI AE200E / EWE AE200E & EWE AE200E & EWE Ma Number of Units (via MELCOBEMS MINI) 8 (via MELCOBEMS MINI) 12,700 12,700 (via Centralised Controller) (via Centralised Controller) Compatibility M Series and City Multi M Series, Mr Slim M Series, Mr Slim M Series, Mr Slim, City Multi and M Series, Mr Slim, City Multi and Mr Slim and City Multi and City Multi Lossnay Lossnay Power Supply 22020v, Hz 22020v, Hz 22020v, Hz 22020v, Hz 22020v, Hz 22020v, Hz Dimensions (mm) (WDH) SMS/GPRS Capabilities SMS G * Ethernet Capabilities SIM Card Provided Inputs Digital / Analogue Digital / Analogue Outputs 1 Digital (Fault) Digital Digital Control On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Monitor On/Off Mode Setpoint Fan Speed Air Direction Permit/Prohibit Filter Sign Fault Codes Room Temperature Weekly Schedule Annual Schedule Night Setback Web Pages Optimised Start Automatic Setpoint Adjustment Load Shedding Occupied / Unoccupied Settings reset Simple Energy Monitoring *1 *1 PRICE 9 1, ,18 1,0 *2 2,0 *2 Note: *1 The energy monitoring is estimated using the outdoor unit data. *2 Discount cannot be applied. * Includes 5 years SIM hosting..1 Controls Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges

168 Services

169

170 Services and Support at every step of the way At Mitsubishi Electric, not only have we developed an innovative range of air conditioning, heating, ventilation and control solutions, we have also eamined how we support the market throughout the complete lifecycle of our products literally from cradle to grave. Whether in presales design and specification, installation and maintenance support, right through to our free recycling programme, we can offer solutions that deliver the quality and ecellence you would epect to help make a world of difference. Contents MELSmart Technical Services Partner Programme Design and Consulting Services MELFinance Solutions Deliveries CPD Accreditation Website and Document Library Services SERVICES

171 5.2 Services Services and Support at every step of the way MELSmart Technical Services Advanced, reliable technical support at every step of the way SERVICES Meeting today s energy challenges for our commercial premises demands more integrated thinking from everyone involved in the design, supply, installation, commissioning and maintenance of essential building services whether it is for an individual property or a national estate. Ever increasing energy bills, the need to reduce carbon emissions and a raft of challenging legislation are driving the demand for increased energy efficiency and control in the cooling, heating, ventilation and associated technologies that we use. As a manufacturer, we realise that product development alone is not enough. To keep our products working at their optimum, we have developed the MELSmart approach to ensure our customers are able to maimise the energy efficiency of their building s services right from the start. MELSmart offers a range of support that includes: Fault Finding Commissioning Spare Parts & Warranty Chiller Replacement Surveys CPD Accredited Technical Product Training System Health Checks Maintenance R22 Audit Surveys 2/7/5 Technical Help Desk Whatever the challenge, we re here to help you meet it. MELSmart Contact Details: Telephone: Option 1 Air Conditioning Technical Option 2 Spares Option Warranty Option Heating Technical Option 5 Returns Option Product Training and Site Services

172 Product Training Mitsubishi Electric has si stateoftheart training suites based at Hatfield, Birmingham, Bristol, Manchester, Scotland and Reigate for your convenience. Providing product training for all levels of epertise, our courses are taught by eperienced engineers, with a wealth of knowledge and are all CPD accredited. For bookings please telephone (Option, Option 1) Product range Course reference PriCe City Multi (VRF) Design and Application CMDA FOC City Multi (HVRF) HVRF Design, Application, Installation and Commissioning HDAIC FOC City Multi Commissioning and Set Up CMPT1 15 City Multi Service and Fault Finding CMPT2 15 M Series and Mr Slim Installation, Service and Fault Finding MPISF 15 Controls Module 1 CTM1 15 Ecodan Design and Application Part 1 ED&A Ecodan Installation and Commissioning Part 2 EI&C Ecodan Service and Fault Finding Part ES&FF Applied Applied Products Design & Application APDA FOC 5. Services Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges SERVICES

173 5. Services Services and Support at every step of the way Commissioning Assistance Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges SERVICES Prior to operation, the MELSmart team ensures that the installation is checked against design specification. Trained technicians ensure that the system is fully operational, and that performance and energy efficiency is maimised. We then confirm whether or not the system is operating within its design parameters and validate any warranties. All onsite equipment is then added to our database where a constant record will be kept of any activities between the site and Mitsubishi Electric. On completion, we will provide a Commissioning Log Book with an accurate operating record of the working system. Type of Visit Fault Diagnostic Site Visit Commissioning (as per commissioning check list) VRF/HVRF Commissioning Chillers & Heat Pump Water Products Maintenance on our water products City Multi Strip Down Controls Commissioning Health Checks PriCe 585 per day 585 per day P.O.A. Survey required See net page 585 per day 585 for up to systems For Controls Commissioning, forms will need to be completed prior to the site visit. Please contact: (Option, Option 2) Design PostInstallation Appraisal / Evaluation PriCe 585 per day

174 City Multi / Chiller Stripdown For installations where the City Multi / Chiller outdoor unit(s) cannot be moved to the final location, Mitsubishi Electric offer a City Multi / Chiller strip down service. Type of Visit unit name PriCe PUHYP200YKB PUHYP2YKB PURYP200YLM PURYP2YLM PUHYEP200YLM PUHYEP2YLM PURYEP200YLM PURYEP2YLM 1,20 per unit PUHYP00YKB PUHYPYKB PUHYP00YKB PURYP00YLM PURYPYLM PURYP00YLM PUHYEP00YLM PUHYEPYLM PURYEP00YLM PURYEPYLM 1,890 per unit PFDP2VM P.O.A. Survey Required PFDP0VM P.O.A. Survey Required PUHYPYKB PURYP0YKB PURYPYLM PURYP0YLM PUHYEP00YLM PUHYEPYLM PUHYEP0YLM PURYEP00YLM PURYEPYLM PURYEP0YLM P.O.A. Survey Required PQHYP200YLM PQHYP2YLM PQHYP00YLM PQRYP200YLM PQRYP2YLM PQRYP00YLM 2,10 per unit Survey Required EACV EAHV NX P.O.A. Survey Required 5.5 Services Any price shown is our commercial price list (CPL) pricing; e VAT Price ecludes any special delivery charges SERVICES

175 5. Services Services and Support at every step of the way SERVICES Mitsubishi Electric Partner Programme The Mitsubishi Electric Partner Programme is inclusive and open to all qualifying air conditioning and heating installation companies, large or small. Using the worldrenowned Mitsubishi Electric brand, we will train, facilitate and promote all qualifying companies as part of our aim to drive the industry forwards. Mitsubishi Electric recognises the importance of forging lasting relationships with professional companies who install our equipment. Our Partner Programme enables us to do just that. Established since 2005 and designed to raise industry standards, our Partner Programme assures end users of a consistently high level of installation and after sales service that supports our systems. To be eligible to join our scheme in the first instance, prospective installation partners must comply with the necessary building regulations and meet specific industry, programme and CSR standards. All partners are reviewed on a regular basis to ensure they continue to meet the required standards that makes them eligible to be part of the Mitsubishi Electric Partner Programme. How to apply for the Partner Programme Speak to your Mitsubishi Electric Representative or partner@meuk.mee.com

176 Partner Programme Benefits Dedicated Partner Programme Coordinator Our dedicated Partner Programme Coordinators are on hand to give Partners the support they need. Joint Marketing / Relationship Development Fund (RDF) We will work with Partners to promote our relationship and generate awareness of the unique business benefits of the Partner Programme to endusers. We operate a Partner Programme Relationship Development Fund (RDF) allocated in relation to their commercial activities with Mitsubishi Electric. Promotional Goods RDF Catalogue Partners can take advantage of their RDF to enhance their company image with dual branded work wear, promotional items and golf accessories. Product and Industry Training Although our Partners receive a free allocation of training courses, additional courses can be funded from the Relationship Development Fund at no further cost to the Partner. 2hr Technical Support To assist our Partners in the maintenance of our equipment we have a dedicated technical support team who will endeavour to speedily diagnose faults and offer solutions to the problems our Partners may encounter. Etended Warranty We will offer all Partners who adhere to our standards eclusive etended product warranties. Sales Leads We will make sales leads available eclusively to our Partners. Business Support Tools We have made it easier to do business with Mitsubishi Electric through the introduction of new technologies and our business tools available to Partners. Factory Visits & Events Our Partners and their clients will have the opportunity to witness firsthand the manufacture of air conditioning and Ecodan units at our manufacturing facility in Scotland. 5.7 Services SERVICES

177 5.8 Services Services and Support at every step of the way Design and Consulting Services As part of the Mitsubishi Electric commitment to supporting robust application of our leading technologies, a team of Consultant Sales professionals work nationally with mechanical building services specifiers and consultants to achieve early engagement in project design. Clients are able to confidently apply cooling, heating, ventilation and controls within their individual projects with the emphasis on a solutionbased philosophy to support asdesigned performance and efficiencies. SERVICES This approach helps projects realise asspecified performance and efficiency levels all designed to achieve the most efficient and costeffective outcome for the building operator, whilst reducing the overall environmental impact. As initial designs move from the drawing board through planning, procurement, installation and commissioning, to ongoing operation and use, we work closely with our customers to balance capital ependiture, system efficiencies, installation costs, control strategies and running costs. Working in the real world Recognising the commercial and delivery pressures of projects in the real world Mitsubishi Electric has in place a number of technically biased Business Development Managers. Our team support the M&E roll out and tackle the challenges associated with change of building use or layout (design evolution) from original design and to support robust value engineering that does not compromise the original design or performance criteria. We understand the link between effective design and achieving the best outcomes for built environment owners, operators and users. The goal of our team is therefore to ensure robust design and to support an equally robust implementation. Getting the right balance between capital cost, system efficiencies, installation costs, control systems and ultimately operating costs all need to be considered at an early stage to ensure a positive outcome. Framing and enabling the marketleading service we offer our clients is the ongoing professional and personal development of our employees to meet ever increasing customer needs in product knowledge, industry practice and legislation.

178 Mitsubishi Electric MELFinance Solutions We developed MELFinance Solutions to respond to current market conditions and the need for customers to manage cash flow, while benefitting from the installation of leading technology to reduce carbon emissions and operational costs. MELFinance Solutions can help end user customers fund the cost of new equipment and its installation via hirepurchase finance. Put simply, this means that (subject to financial status), an enduser customer can repay the combination of 'fied asset' and maintenance costs over an agreed period of between 1 to 5 years. For qualifying companies, it is a fleible alternative to a traditional bank loan that provides significant cash flow and ta benefits: No need for hefty deposits Finance deals are secured wholly or largely on the heating, cooling and/or ventilation equipment being financed Stronger cash flow Releases tiedup cash and preserves other forms of credit for other business or operational needs Fied, regular payments Helps you plan for the future by eliminating uncertainty and costly surprises Quick decisions We always aim to provide a prompt turnaround for funding applications Immediate payment Settlement of the full installation and equipment invoice upon installation/delivery The fiveyear, "troublefree" cooling, heating and ventilation finance package offers a host of advantages integrating onsite installation and commissioning fees, minimum threeyear warranty on all Mitsubishi Electric equipment, scheduled maintenance visits and 2/7 emergency technical helpline for any onsite issues. To get your no obligation finance proposal visit: or MELFinanceSolutions@meuk.mee.com Mitsubishi Electric Europe B.V. holds a Consumer Credit Licence no for credit brokerage. As from 1 April 201: Authorised and regulated by the Financial Conduct Authority as a credit broker. Hirepurchase finance will be considered subject to status by an independent finance house as facilitated by Mitsubishi Electric. Finance house's terms and conditions apply. This website tet does not constitute an offer to supply goods/services or provide or arrange hirepurchase finance. Finance only available where you enter into Mitsubishi Electric's contract package for removal of any eisting installation, design, supply and commissioning services. Package is conditional on you entering into (i) a maintenance contract for the installation and (ii) a hirepurchase agreement with Mitsubishi Electric's finance partner. Otherwise, all goods are supplied subject to Company's General Terms and Conditions of sale, copy available upon request. 5.9 Services SERVICES

179 5.10 Services Services and Support at every step of the way Mitsubishi Electric Deliveries SERVICES At Mitsubishi Electric, we take our delivery programme very seriously because we realise that our customers businesses can depend on getting the right equipment on site at the right time. That s why we have developed a comprehensive and fleible delivery programme with one of the longest delivery windows in the industry. With the ability to offer timed, weekend and Public Holiday deliveries, coupled with free Tet Ahead and Ring Ahead functions, we aim to keep our customers informed every step of the way. Delivery Notes Cut off for net day deliveries is 2.0pm on the working day prior to delivery Standard delivery is between 8.00am and 5.0pm AM / PM / Timed / Weekend / Public Holiday deliveries are all available (additional notice needed and charges will apply please refer to full delivery guidelines for further details) Standard delivery will normally be made on an 18T rigid lorry equipped with a tail lift and a single driver with a pump truck Other vehicle types will be utilised dependant on any site access issues and delivery size If there are access restrictions at your nominated delivery point and a vehicle other than an 18T lorry is required, this will need to be booked in advance and a charge may apply Our Tet Ahead and Ring Ahead functions are available on all deliveries with the eception of parcel providers, which will offer Tet Ahead only Deliveries available via HIAB (Flatbed vehicle with crane) / with chapter 8 signage require 8 hours notice and etra charges may apply We offer a 2man delivery service, removal of packaging and a stair walker these require 8 hours notice and etra charges will apply Mitsubishi Electric is an Associate Member of the Fleet Operator Recognition Scheme (FORS) and all of our vehicles are FORS accredited to Bronze level Collection is also available from our Milton Keynes warehouse these must be prearranged and require at least hours notice Returns to be notified within 15 working days Terms and Conditions apply For further information on our recycling service please refer to the website recycling.mitsubishielectric.co.uk

180 CPD Information Guides Mitsubishi Electric is accredited by the Construction CPD Certification Service in many different areas. We have produced a number of Industry Information Guides that are available to download from our document library. We also run a number of CPD seminars and training courses across the UK. To find out more, simply contact your local Mitsubishi Electric sales office. Mitsubishi Electric Website and Document Library Website For further information on any of our products and services please visit our website, livingenvironmentalsystems.mitsubishielectric.co.uk which has been designed to provide a detailed overview of the energy saving solutions we can provide you. The smart, clean and modern design of the site focuses on the features and benefits that Mitsubishi Electric equipment has to offer and hosts our Air Conditioning, Heating, Corporate Solutions and Green Gateway websites under one umbrella, making it easy for visitors to navigate between them. The websites not only promote our comprehensive product offerings but have also been designed to inform and educate visitors, with pages dedicated to the very latest legislative challenges that face all those involved in the built environment. Document Library Our website: library.mitsubishielectric.co.uk also includes a comprehensive Document Library which features all current operating and installation manuals, as well as product literature, CPD guides and more. This means there is no longer a requirement for visitors to login to our sites to download the latest product and technical information. To add to this, a document library app is also available allowing visitors to access this information simply from their tablet or smart phone Services SERVICES

181 Telephone: MELSmart Technical Services: Option 1 Air Conditioning Technical Option 2 Spares Option Warranty Option Heating Technical Option 5 Returns Option Product Training and Site Services livingenvironmentalsystems@meuk.mee.com website: livingenvironmentalsystems.mitsubishielectric.co.uk website: recycling.mitsubishielectric.co.uk New Content Hub coming 2017: thehub.mitsubishielectric.co.uk UNITED KINGDOM Mitsubishi Electric Europe Living Environment Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: Fa: IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 2, Ireland Telephone: Dublin (01) Fa: Dublin (01) International code: (0051) Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 201. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company s General Conditions of Sale, a copy of which is available on request. Thirdparty product and brand names may be trademarks or registered trademarks of their respective owners. Note: The fuse rating is for guidance only. Please refer to the relevant databook for detailed specification. It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions. Mitsubishi Electric s airconditioning equipment and heat pump systems contain a fluorinated greenhouse gas, R10A(GWP:2088), R2(GWP:75), R07C (GWP:177) or R1a (GWP:10). *These GWP values are based on Regulation(EU) No 517/201 from IPCC th edition. In case of Regulation(EU) No.2/2011 from IPCC rd edition, these are as follows. R10A(GWP:1975), R2(GWP: 5), R07C (GWP:1) or R1a (GWP:100). Note: Prices effective as of 1st January 2017 Any price shown is our commercial price list (CPL) pricing; e VAT Sales channels are free to set prices as they see fit: actual prices may vary from CPL Price ecludes any special delivery charges Designed by Square Bear Ltd

182 Sales Contacts Logicool Air Conditioning & Heat Pumps Limited Unit 1, The Machine House Newfields, Moira, Swadlincote Derbyshire DE12 EG T F E sales@logicoolac.com W logicoolac.com Mitsubishi Electric s airconditioning equipment and heat pump systems contain a fluorinated greenhouse gas, R10A(GWP:2088) or R2(GWP:75). *These GWP values are based on Regulation(EU) No 517/201 from IPCC th edition. In case of Regulation(EU) No.2/2011 from IPCC rd edition, these are as follows. R10A(GWP:1975), R2(GWP: 5).

The Mr Slim Inverter Cassette Range

The Mr Slim Inverter Cassette Range The Mr Slim Inverter Cassette Range Mr Slim Inverter Cassette Range Ideal for use in small offices, retail and leisure The Mr Slim Inverter Cassette Range offers customers all the features and benefits

More information

Air Conditioning. SEZ-KD Inverter Heat Pump. Product Information. Ceiling Concealed Ducted System

Air Conditioning. SEZ-KD Inverter Heat Pump. Product Information. Ceiling Concealed Ducted System SEZ-KD Inverter Heat Pump Ceiling Concealed Ducted System SEZ-KD Inverter Heat Pump Ceiling Concealed Ducted System Designed for offices, restaurants or shops, the SEZ-KD series operates at low noise levels.

More information

Multi-Splits. Split-System Air Conditioning. Multi-Splits

Multi-Splits. Split-System Air Conditioning. Multi-Splits Multi-Splits Split-System Air Conditioning Multi-Splits The Flexible Multi-Split Range Available in a variety of options, our Multi-Split range fits in wherever it s needed. M Series MXZ or Mr Slim twin,

More information

M Series & Mr Slim. Split-System Air Conditioning

M Series & Mr Slim. Split-System Air Conditioning M Series & Mr Slim SplitSystem Air Conditioning Air Conditioning Domestic Heating Commercial Heating Photovoltaics Mitsubishi Electric SplitSystems M Series and Mr Slim Energy Saving: Reduced Power Consumption

More information

Multizone Multi Split systems

Multizone Multi Split systems 19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6

More information

Residential. Hot Water. Commercial. XRV Multi-System. Controls. Technical courses

Residential. Hot Water. Commercial. XRV Multi-System. Controls. Technical courses 2012 Hokkaido is a brand of Termal Group, based in Italy and present in the international market, which for 30 years has been a leader in the air conditioning sector throughout Europe. It is a brand that

More information

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by New ECOi Electric 2 and 3 pipe VRF systems 2006/7 Range 1 All round air conditioning by ECOi the next generation of 2 and 3 pipe electric SANYO is justifi ably proud of being renowned for developing unique

More information

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s

More information

Engineering Data Book

Engineering Data Book Engineering Data Book Contents Specifications 2 Dimensions of Indoor 3 and outdoor units Indoor unit Outdoor unit Wiring diagrams 6 RAS-05BKV-E RAS-07BKV-E RAS-05BAV-E RAS-07BAV-E Sensible capacity table

More information

PREMIUM INVERTER DUCTED AIR CONDITIONING

PREMIUM INVERTER DUCTED AIR CONDITIONING PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

modular multi intelligent, environmental and versatile

modular multi intelligent, environmental and versatile modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor

More information

PRODUCT LINEUP MULTI SPLIT

PRODUCT LINEUP MULTI SPLIT 068 PRODUCT LINEUP Energy saving design to provide a comfortable indoor environment while being environment-friendly. An air conditioner that is people-friendly is also environment friendly. Fujitsu General

More information

VRF Mini Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group

VRF Mini Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group Coercial Air Conditioners 16 VRF Mini Series 50Hz Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West Region of Midea Coercial Air Conditioner

More information

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology Slim Ducted Systems Two choices of selection for the air inlet flow Natural drain discharge port and drain pump (up to 850 mm) Cleanable pre-filter included Slim Ducted Systems Digital Inverter Four steps

More information

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,

More information

VRF. For Commercial and Light Commercial

VRF. For Commercial and Light Commercial 118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,

More information

PRICE LIST

PRICE LIST PRICE LIST 2014-2015 100% PRODUCTION 100% PANASONIC TESTING AND QUALITY ASSURANCE RESEARCH & DEVELOPMENT AND DESIGN SERVICE PROVIDER PRO Club: the professional website of Panasonic Panasonic has an impressive

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 00 Air Conditioning System 00 Air Conditioning System Enjoy a clean

More information

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the

More information

Now there s a sleek new profile in heat pumps

Now there s a sleek new profile in heat pumps New RELEASE Now there s a sleek new profile in heat pumps The Mitsubishi Electric Designer Series has been awarded the if Product Design award for its simple and elegant design. The clean, flat surfaces

More information

Samsung Multi split 2017

Samsung Multi split 2017 GOODBYE SQUARE AIR Samsung Multi split 2017 SAMSUNG AIR CONDITIONING VRF SPECIFIERS DESIGN GUIDE 4 th EDITION 1 www.samsung.com/uk/dvms Samsung is moving with, and ahead of, our customers Put simply, our

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information

DC INVERTER DUCTED AIR CONDITIONERS

DC INVERTER DUCTED AIR CONDITIONERS DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies

More information

Residential multisplit Duo/Trio/Quattro/Cinco DC Inverter

Residential multisplit Duo/Trio/Quattro/Cinco DC Inverter YCZ Residential multisplit Duo/Trio/Quattro/Cinco DC Depending on combination HKD COMPATIBLE WITH HND CBD DCD A ++ XAD 2016 YCZ Residential multisplit Duo/Trio/Quattro/Cinco DC COMPATIBLE WITH HIGH WALL

More information

Ductless F L EXIBIL ITY IS F R EEDOM. Fl ex Fit d uc t l ess system. Higher Comfort, Haier Living

Ductless F L EXIBIL ITY IS F R EEDOM. Fl ex Fit d uc t l ess system. Higher Comfort, Haier Living Ductless F L EXIBIL ITY IS F R EEDOM I n t ro d uc in g t h e H a ie r Fl ex Fit d uc t l ess system A What is FlexFit? FlexFit is a top-of-the-line modular system that allows for optimal ductless pairings

More information

2010 Duct-Free Splits Line Card

2010 Duct-Free Splits Line Card 2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette,

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 9-24K High Walls 18-24/6/42/60K High Walls, Cassette, Underceiling 2:1 to

More information

CEILING CONCEALED SPLIT SYSTEM C SERIES

CEILING CONCEALED SPLIT SYSTEM C SERIES CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.

More information

MSZ-LN VGHZ The new generation heatpump

MSZ-LN VGHZ The new generation heatpump MSZ-LN The new generation heatpump MSZ-LN will have tentative sale start of May 2017, Three different color variations and sizes. Greatly Improvements of capacity at -25 C with up to 35% better performance

More information

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning Technical Data RZQG-L(8)Y1 Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz M-SERIES SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-2C20NAHZ ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP; for use with

More information

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems CityM-DK-F Air curtains for Sky Air Biddle City air curtains are the ideal solution for retailers and consultants to

More information

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system ceiling wall Large and wide airflow High efficiency Low noise Large centre display Easy maintenance Inverter options Automatic filter cleaning options Easy-to-use remote controller AWYZ14LB/18LB With the

More information

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160) FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioning 100% outside air About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette, Underceiling 2:1 to

More information

Digital Inverter 4 series

Digital Inverter 4 series TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E

More information

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs. PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.

More information

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer Midea VRFs/ Midea V5X Timothy Huang Senior Engineer VRF Product Overview General Features V5X Key Technologies V5X VRF product strategy VRF line-up Fresh air solutions Selection software Unique Innovations

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS 2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 High Wall High Wall, Cassette, Underceiling 2:1 to 5:1 High Wall Up to 23.0

More information

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018 Higher Comfort, Haier Living 2018 MRV-S (Mini VRF) Product Brochure rev 01012018 Ductless HAIER MRV MILESTONES MRV-S KEY FEATURES Haier is one of the leading producers of HVAC products, having the capacity

More information

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME Ducted Air Conditioning Specialists With ore than 0 years of experience, exporting to ore than 120 countries around the world, Panasonic is unquestionably

More information

SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Yes Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Yes Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz M-SERIES SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port Adapter (MAC-A455JP-E)

More information

LG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.

LG HVAC SOLUTION. LG Electronics.   Distributed by. Copyright 2017 LG Electronics. All rights reserved. 2 0 1 7 2017 LG HVAC SOLUTION LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. ULTIMATE INVERTER COMPRESSOR As the core technology

More information

AIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit

AIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit AIR CONDITIONING SYSTEMS Debuting the New Multi System Maximum comfort for 5 rooms, using 1 outdoor unit Debut of the New Multi System Built to Serve up to Five Rooms in All! N e w One Outdoor Unit Handling

More information

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014 FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation

More information

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR 20 SERIES - ENHANCED CAPACITY DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE www.daikincomfort.com "I'm

More information

PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL IRSTGE Systems can be designed to create an air conditioning solution to suit most buildings requirements. IRSTGE Systems can be designed to effectively provide an air conditioning solution from a large

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application September 2014 Ductless Split s Right Product for the Right Application Single-Zone s Multi-Zone s (up to five rooms) High Wall High Wall, Cassette,

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

SUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

SUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES SUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-3C30NA2 ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port

More information

Models: 12 and 18. Models: 24 to 60

Models: 12 and 18. Models: 24 to 60 SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump

More information

VRF (System Air-Conditioner)

VRF (System Air-Conditioner) The World Leader in Air-Conditioning, Heating & Home Appliances Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. Best in Class

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

24% higher part-load efficiency saves running costs.

24% higher part-load efficiency saves running costs. Danfoss Scroll Compressors SH485 The family is growing Get more for less with the big blue The unique design of the SH485 offers a compact and innovative 40-ton capacity scroll in the size of a 30-ton

More information

Cool with the sun and save 60% of your power

Cool with the sun and save 60% of your power Cool with the sun and save 60% of your power Saves up to 60% of your electrical power Same prices as non solar systems (incl. panel!) Top technology with attractive indoor units Heat pump for cooling and

More information

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A Submittal Data: Multi-Room Ductless heat-pump systems 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A Submittal Data: Multi-Room Ductless heat-pump systems 48,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Hitachi Multizone Heat Pump Air Conditioning

Hitachi Multizone Heat Pump Air Conditioning Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in

More information

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS UP TO 20 SEER PERFORMANCE HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS Energy Star ratings are dependent upon conditions beyond equipment installation. To make certain your HVAC equipment

More information

DC INVERTER VRF SYSTEMS C-VRF

DC INVERTER VRF SYSTEMS C-VRF DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor

More information

Air-conditioning. split ducted systems

Air-conditioning. split ducted systems Air-conditioning split ducted systems 1300 306 125 www.sygnal.com.au Dual Inverter *high static, variable refrigerant flow, variable indoor airflow SYSTEM MODEL HS-IV-10 HS-IV-14 HS-IV-17 INDOOR UNIT MODEL

More information

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz M-SERIES SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-5C42NAHZ ACCESSORIES Three-port Branch Box (PAC-MKA30BC) Five-port Branch

More information

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

Four-Way Ceiling Cassette

Four-Way Ceiling Cassette Benefits of Multi F Systems Individual zone control Operating ranges of 14 F to 118 F in cooling and 0 F to 64 F in heating Quiet and comfortable environment Safer and easier installation with Cost efficient

More information

WELCOME TO THE COMMERCIAL RANGE. NEW PACi TECHNOLOGY

WELCOME TO THE COMMERCIAL RANGE. NEW PACi TECHNOLOGY WELCOME TO THE COMMERCIAL RANGE NEW PACi TECHNOLOGY 128 NEW / COMMERCIAL Here are some of your new air conditioner s major features. Panasonic has developed an impressive range of highly efficient Commercial

More information

Ductless Systems. Right product for the right application. Fall 2015 Edition

Ductless Systems. Right product for the right application. Fall 2015 Edition Ductless Systems Right product for the right application Fall 2015 Edition Right Product for the Right Application Single Zone - Residential Single Zone - Light Commercial Multi-Zone RAV-**KRT System High

More information

Price List. Prices effective as of 1st January 2018

Price List. Prices effective as of 1st January 2018 Price List 2017 Prices effective as of 1st January 2018 Welcome to Mitsubishi Electric Mitsubishi Electric is a market leader in providing solutions to cool, heat, ventilate and control our buildings.

More information

L E D L I G H T I N G P A N E L S S T R I P S L A M P S - L E D.

L E D L I G H T I N G P A N E L S S T R I P S L A M P S - L E D. LED LIGHTING PANELS STRIPS LAMPS w w w. i n t e g r a l - L E D. c o m Panels Integral retrofit LED panels are an easy-to-install replacement for less efficient fluorescent tube panels. Not only are LED

More information

Emergincyoperation Widevoltagerangeoperation Powersupplysecurity Continuousoperationofindoorunit PCBprotectiondesign Anti-corosion

Emergincyoperation Widevoltagerangeoperation Powersupplysecurity Continuousoperationofindoorunit PCBprotectiondesign Anti-corosion www.refra.eu VRF SYSTEM S Quietoperation Lownoisedesign Precisetemperaturecontrol Inteligentdefrosttechnology Individualcontrol Modularoperating Emergincyoperation Widevoltagerangeoperation Powersupplysecurity

More information

Price List Issue 2

Price List Issue 2 Price List 2018 Issue 2 Welcome to Mitsubishi Electric Mitsubishi Electric is a market leader in providing solutions to cool, heat, ventilate and control our buildings. As a major manufacturer of some

More information

LG MULTI SPLIT SYSTEM

LG MULTI SPLIT SYSTEM 50Hz LG MULTI SPLIT SYSTEM Unlike traditional multitype units, it is a nextgeneration multitype airconditioner designed to be installed under any circumstance. LG Multi Split System Why? LG Multi World

More information

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls. RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Heat pumps for swimming pools

Heat pumps for swimming pools Heat pumps for swimming pools Full range of heat pumps for indoor and outdoor swimming i pools The best heating for your pool Reliable and effective Made in Europe www.certikinpoolsindia.net THE CHALLENGE:

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant

More information

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24RMVJU Efficiency SEER EER HSPF COP Non-Ducted 18 12.7 12.5 3.53 Ducted 14 9.7 8.2 3.44 Mixed 15.95 11.2 10.35 3.49 Performance

More information

T Series. The most reliable HVAC system for transit is now better than ever.

T Series. The most reliable HVAC system for transit is now better than ever. T Series The most reliable HVAC system for transit is now better than ever. High performance and reliability for more than 30 years T-Series: The HVAC design that changed an industry. Low life cycle costs

More information

Chilled Water Vertical Fan Coils

Chilled Water Vertical Fan Coils PRODUCT MANUAL Chilled Water Vertical Fan Coils Models: FWMW-C FWMW-H FWCW-C FWCW-H INDEX Vertical Fan Coil page 2 General Characteristics page 3 Technical data page 7 Sound Level page 9 Operating Limits

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. Reference Approval

More information

NEW PRODUCTS EFFICIENT SOLUTIONS PRICE LIST

NEW PRODUCTS EFFICIENT SOLUTIONS PRICE LIST NEW PRODUCTS 2018 2019 EFFICIENT SOLUTIONS PRICE LIST DOMESTIC P. 8 PANASONIC: ECO & SMART IDEAS FOR A SUSTAINABLE LIFESTYLE COMMERCIAL P. 40 Panasonic Green Innovation Company. We will make the environment

More information

PERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less

PERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less Air Conditioning Solutions 2016 360 CASSETTE CIRCULAR DESIGN Its full-circle design allows it to be placed beautifully in any setting. PERFECTLY EVEN COOLING Innovative 360 degree airflow ensures optimal

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

low carbon centrifugal Pod blowers

low carbon centrifugal Pod blowers low carbon centrifugal Pod blowers torin-sifan For over 100 years, torin-sifan have been a leader in servicing the Air Movement requirements of our customers. From our Head Office and Manufacturing facility

More information

LG Multi Split Air Conditioners

LG Multi Split Air Conditioners AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

MULTI SPLIT SYSTEM AIR CONDITIONERS

MULTI SPLIT SYSTEM AIR CONDITIONERS MULTI SPLIT SYSTEM AIR CONDITIONERS Come home to comfort with LG The Total HVAC and Energy Solution Provider Ever since manufacturing orea s first homegrown air conditioner in 1968, L has remained at the

More information

Screw Compressors. Below 37 kw. People. Passion. Performance.

Screw Compressors. Below 37 kw. People. Passion. Performance. Screw Compressors Below 37 kw People. Passion. Performance. People. Passion. Performance. Define your needs, our broad Going for our extensive offer of oil-injected screw compressors below 30kW, you choose