General Description. BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management

Size: px
Start display at page:

Download "General Description. BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management"

Transcription

1 General Description BADICHEQ Chapter1: Introduction I: The problem General Description BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management Lead acid batteries are employed for energy storage since more than 100 years. However the use of traction- and stationary batteries causes trouble until to-day. - Short lifetime of cells or blocs, - Short operating period in spite of correct charging and handling, - Controversial discussions with regard to reasons and responsibility in case of battery failure. In this document battery stands for cells or blocs of the same nominal voltage connected in series. Cell stands for an individual cell but also for a battery bloc. The reasons for failures are in general an inadequate technology of battery charging, that is still prevalent until to day. The total voltage is used to determine the charge current. Even if the correct voltage is respected overcharging of individual cells cannot be avoided. The result is loss of time, energy and electrolyte. Furthermore the charge indication is wrong because the Ahs supplied to the overcharged cells are not completely chemically transformed. Another problem consists because the cells suffer a consecutive difference of their respective charge levels. The equalizing of the charge levels demands voluntary overcharging of the whole battery from time to time, (Equalizing charge) which results in losses of time, energy and electrolyte. In case of omission of the equalizing charge deep discharges may occur and even polarity changes of cells are possible. If one cell fails by a short cut, other cells will be severely overcharged because a standard charger cannot detect the lacking voltage of one cell. II: Requirements The following requirements must be fulfilled for an economic operation of a battery installation composed of several cells connected in series: - Max. operating time - The capacity should remain the same during the whole operating time, independent of ambient conditions.

2 General Description BADICHEQ Min. maintenance costs Units connected in series have divergent capacities due to fabrication tolerances. New batteries have only % of their nominal capacity. They reach the full capacity just after a determined number of cycles or operation under charge conservation. Furthermore the capacity depends on the ambient temperature. Different temperatures may occur within an arrangement of batteries but also in various groups of batteries. Under consideration of these facts it is necessary to do the following, when individual blocs or cells are connected in series: - all units have to be charged to the same level, - all units have to be maintained at the same temperature - the weakest unit has to be protected against overcharging or deep discharge. III: Problem solution The battery management system BADICHEQ monitors all cells during charging and discharging and considers always the weakest or strongest cell. As soon as one cell reaches the preset final voltage the charge current is reduced by an optional PWM signal and the charge continues according to a given characteristic curve, if the charger is able to use the signal. To protect the battery the discharge current can be reduced as soon as the battery reaches a preset voltage or if the capacity reaches a preset level. The BADICHEQ with an integrated small charger applies an additional charge to individual cells. During voltage measuring, the temperature is considered within the various groups of batteries. It is possible by help of an analogue or digital instrument to measure the capacity level and the charge current. The battery status is indicated in % of the nominal capacity. Three LEDs show the general condition of the battery. The behaviour and the voltage status of three cells are recorded during 128 cycles and can be analysed for servicing and in case of guaranty problems. The experience made with the BADICHEQ during 1000 applications has shown that this device takes care of the battery and extends its lifetime. BADICHEQ however cannot substitute the physical laws and facts. When operating the batteries one has to take care that great temperature differences are avoided between the individual batteries. Chapter 2: Description, Structure, Action I: General In September1992 the BADICHEQ 3000 has been first presented to the public. 2 patents now protect its technical features and the unit has been installed since more than 1000 times. The BADICHEQ 3000 has proofed that it is a compact fully automatic system for a reliable battery management:

3 General Description BADICHEQ Up to 48 cells are analysed (with an additional card up to 288 cells can be monitored) - Needing cells are individually charged in addition, - The main charge current can be regulated per cell (CRCS), (Only possible with a charger controlled by the BADICHEQ) - The real available capacity which does not damage the battery is indicated either digital or analogue. - A deep discharge protection is provided (relay contact), - Relevant data during 128 cycles are stored and can be read by a PC through an interface RS 232. * cell stands for a unit of 2, 6 or 12V It is possible to monitor a greater number of batteries or cells by connecting several units. For example connecting 6 BADICHEQ 3000 can monitor 192 cells of 2V. Each unit serves 32 cells. All individual sectors can be visited by a WEB interface which is part of the delivery. The system can be used for different types of batteries. The parameters can be programmed for almost all applications. Until to day the unit has been used for batteries made by Sonnenschein, Hagen, Saft, Varta, Trojan, Deta, Bären, Hawker, Panasonic, Horizon (USA), Oldham, and CMP. Extensive experiences and a reliable control algorithm are available. No cell will be overcharged due to the cell related control of the charge current (CRCS). As soon as one cell reaches the final charge voltage the charge current is reduced... Additional charge will be applied individually to cells that have not yet reached the final voltage by help of an integrated charger (max 20W) of the BADICHEQ. The effect is that after a certain number of charge cycles each cell is fully charged in relation to its individual capacity. This condition is monitored and maintained. The indication of the remaining available capacity considers the dependence on current and temperature of the capacity. Three separate temperature sensors monitor the ambient temperature of the battery during all measurements. The WEB-Interface Badicheq 3000 All battery data can be displayed by help of an SNMP Adapter (separate order) and the integrated web interface via intranet or with a router also via the internet. Further information is given in the BADICHEQ 3000 Webinterface documentation. Synopsis of battery installations via web interface

4 General Description BADICHEQ The status functions A tailor made concept in combination with a control algorithm created after many trials made it possible to design an affordable device that is able to face severe technical, climatically and electromagnetic conditions and overcome all technical problems II: Structure and mode of action The nucleus of the BADICHEQ is a cell-selecting network controlled by a microprocessor. Each cell can be connected with a voltage meter and a BADICHEQ integrated charger. The status data and the consolidated data of 128 cycles (charge and discharge) are stored in a battery supported (S-RAM).

5 General Description BADICHEQ The charger integrated in the BADICHEQ consists of a blocking converter and develops 20W independent of the cell voltage. The output current is limited at 5A, the output voltage at 24V per measuring unit. Help of a 60mV Shunt and two measuring amplifiers measures the battery current. To measure the temperature 3 input terminals are provided for temp sensors with 10mV/K, Ib<1mA. The assignments of cells and sensors within the BADICHEQ software are made in the factory according to the specification given with the order. An analogue display with 3 LEDs can be provided that shows the remaining capacity, the actual current and possible system defects. The display connects easily with the BADICHEQ by means of a 2 or 3 core cables... The data exchange with a PC takes place via an RS 232 interface. The PC has to be IBM compatible with the following min. configuration: - Win9x, WinNT, Win2000, WinXP operating system, - free RS 232 interface (the interface must not be used by an internal modem or similar device), The necessary level adaptation for a data transfer by an RS 232 interface is made in an interface component that is incorporated between the PC and the BADICHEQ. This RS232- Interface is supplied with potential separation. The PC is connected with the negative battery terminal. To control the main charger (current, set value for CRCS) a second potential free PWMoutlet is available. (Opto coupled transistor outlet) A further PWM-signal can be used to influence the discharge current subject to the charge condition of the battery. (To be discussed when ordering) The battery only powers BADICHEQ. This means that additional charging of individual cells can be performed any time, not dependent on the external power supply. Therefore no backlash, no radio interference, no dangerous voltages appear. The BADICHEQ 3000 can be used for batteries up to 576V total voltage. All measuring lines are directly connected to the BADICHEQ. For the connection of the lines to the temperature sensors, the shunt, the display a 37-pin D-SUB plug is provided. III: Advantages Long lifetime of the battery - Avoidance of overcharging of individual blocs, overheating and loss of electrolyte

6 General Description BADICHEQ no over-all equalization charge that damages all blocs by overheating and loss of electrolyte - Avoidance of deep discharges because the necessary additional charge is computed - no loss of lifetime through cycling - Charge procedure: The total battery is charged with an optimised charger as an individual bloc Reduction of the operating costs Other advantages Conditions - use and exchange of uncycled blocs is possible - increased efficiency because no over-charging - no waste of time and energy for equalizing charges - economy of maintenance costs and capacity tests in a workshop - economy of service costs due to rapid failure analysis - appraisal and testing of the installation via optional data lines with internet or LAN - optional incident information to service personnel via GSM - max. availability because of permanent optimal charge balance - maintenance free and fully automatic operation - Reduction of the mean charge time with a charger controlled by the system - comprehensive information with regard to the history of the battery - rapid clarification of guaranty problems Each battery terminal must be connected to the BADICHEQ via lines of 0,75qmm. The lines must be fused near to the battery (max 5A with according voltage) Chapter 3: Technical characteristic main values Max number of cells: 48, with extension module up to 288 Measuring range of cell voltage: 0-1.5x cell nom. voltage Resolution: 0.1% final value of the effective range Max. error: 1% final value of the effective range Temperature drift during voltage measurement: <0.3% of the total temperature range Effective range charge/discharge current: 0-0.7x / 0-1.5x (60mV ) shunt, nom. current Resolution, total error: 0.1% / 0.5% effective range +1%rdg Temperature drift during current measurement: <0.5% of the total temperature range Effective range temperature measurement: - 20 up to +75 C Resolution, total error: 1K/3K (LM235) PWM outputs / frequency: 3 / 2kHz

7 General Description BADICHEQ PWM output voltage and current Relay terminals deep discharge PC coupling: Range of supply voltage: Power consumption: Current of the additional charge: Temperature range Calculated lifetime: Weight/dimensions (HxWxD): 27V / 5mA 220V~ / 2A RS 232, 9.6kBaud 30V up to 660V DC ca. 2,5W, 6W with active display 20W / cell voltage, max. 5A - 0 C to +45 C ambient temperature >15 years with 300 cycles ca. 5 kg / 600x300x150mm (up to 62 cells) ca.20kg / 700x550x350mm (at 288cells) Chapter 4: Scope of delivery All BADICHEQs 3000 in their standard version are designed to monitor 32 cells. It is possible to increase or decrease the number of cells by additional components to screen from 12 up to 288 cells. The max nom. total voltage is 576V. This means that max 48 blocs of 12V or 288 blocs of 2V can be supervised. The exact number of cells should be indicated when ordering. All BADICHEQs are installed in plastic housings. Units for12 up to 28 cells meet the requirements of safety class IP 20, units for 30 up to 288 cells are supplied with a housing that meets the safety class IP 54. The measuring lines to the individual cells are directly connected with the BADICHEQ. Display, shunt, additional temperature sensors, interface adapters and appraisal software are not included in the unit price. They should be ordered separately. Order The BADICHEQ can be adapted to almost any battery type, due to its hardware configuration. This is also valid for the charge procedure, if the cell related charge characteristic (CRCS) is selected and the charger can be controlled accordingly. Each BADICHEQ is preset by the factory for the wanted application. Your order must include the following information: - Nom. Voltage and number of cells or groups of cells to be monitored - Type of battery and manufacturer - Nom. current and voltage for the shunt - Number and allocation of the temp. sensors (max. 3) To prepare the measuring lines we need in addition: - Number of temp. sensors (max 3) and the respective cable lengths, - For each sensor the allocated cell numbers, - Length of the shunt cable. A personal conversation should be held to determine i.e. a specific charge characteristic etc. Technical information/contribution of the customer:

8 General Description BADICHEQ A fused 230 VAC supply per data cabinet near to the BADICHEQ 3000 has to be provided, - A network interface is needed at the installation place near to the BADICHEQ A fused 230 VAC supply and a network interface is needed for each data cabinet in each room if the batteries are located in different rooms!

9 General Description BADICHEQ Chapter 5: Wiring diagrams Example: BADICHEQ 3000, model for 32 batteries of 12V, incl. one temp. sensor and an integrated LED display - LED green: power charge / trickle charge - LED yellow: battery discharge / low voltage of the bloc - LED red: battery fault / unit fault

10 General Description BADICHEQ Sample, graphical representation of the housing

11 General Description BADICHEQ Wiring diagram BADICHEQ 3000 and SNMP

12 General Description BADICHEQ Sample Representation of the LED display

All In one uninterruptible power supply solutions

All In one uninterruptible power supply solutions All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing

More information

80V 300Ah Lithium-ion Battery Pack Data Sheet

80V 300Ah Lithium-ion Battery Pack Data Sheet 80V 300Ah Lithium-ion Battery Pack Data Sheet 80 V, 300 amp-hour capacity, maintenance-free energy storage, IP65 design, fully integrated BMS, integrated fuse and safety relay protection, highly configurable

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Est Battery Data Logger BDL3000

Est Battery Data Logger BDL3000 Est.1968 Battery Data Logger BDL3000 Concept The Thycon Battery Data Logger (BDL) measures, stores, displays and analyses multiple battery parameters continually without user intervention. The BDL combines

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No. User Manual ZSP100 Document No. 0658.00.95-03.2 Page 1/6 MERAWEX Sp. z o.o. Toruńska 8 44-122 Gliwice Poland tel. +48 32 23 99 400 fax +48 32 23 99 409 merawex@merawex.com.pl http://www.merawex.com.pl

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

»The next Level of Energy Management«

»The next Level of Energy Management« GNB Industrial Power Exide Technologies, with operations in more than 80 countries, is one of the world s largest producers and recyclers of lead-acid batteries. Exide Technologies provides a comprehensive

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

CBI All in One DC UPS Power Solutions

CBI All in One DC UPS Power Solutions CBI All in One Power Solutions Everything and more! More efficiency of the battery thanks to continuous control over time. More monitoring in main connection nodes: input, output load, battery. Event logging:

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l Pg. 2 / 32 LIFEPO4 BATTERY CHARGER CB1203 3 Amp charger / Xtra Small Compact and inexpensive battery charger!!! Use with Aliant X, X-P and YLP series / from 2 to 20Ah ACCESSORIES This battery charger is

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Current Automation Catalogue

Current Automation Catalogue Current Automation Catalogue Page 1 Visit our website for more indebt info on this product range Current Automation Catalogue Page 2 STECA Steca Solar Charge Controllers Steca Solar Charge Controllers

More information

Programming of different charge methods with the BaSyTec Battery Test System

Programming of different charge methods with the BaSyTec Battery Test System Programming of different charge methods with the BaSyTec Battery Test System Important Note: You have to use the basytec software version 4.0.6.0 or later in the ethernet operation mode if you use the

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER DESCRIPTION Battery management is implemented in the Aspiro and Guardian DC Power Systems using the ACC Extended (ACX) controller. ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER The

More information

Cellwatch Battery Monitoring Systems

Cellwatch Battery Monitoring Systems Cellwatch Battery Monitoring Systems A battery can fail overnight leaving an entire power system without backup capability... So what did your batteries do today? If you want to know, read on... Cellwatch

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller Rover Series Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.5 Important Safety Instructions Please save these

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER USER MANUAL βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER (OPTIONAL) CHARACTERISTICS LCD display: all systems parameters

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

Uninterruptible power supplies (UPS)

Uninterruptible power supplies (UPS) Contents Overview.2 UPS control unit.4 attery modules.6 uffer modules.8 1460790000 2014/2015.1 Overview Uninterruptible power supplies Weidmüller s uninterruptible power supplies reliably protect 24 V

More information

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE SECTIONS: ENGLISH 2 NEDERLANDS 17 DEUTSCH 37 Victron Energy BV De Paal 35 1351 JG Almere-Haven The Netherlands Article number

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries 8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A Charges & Maintains Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries USER S MANUAL 5 User s Manual And Guide To Professional Battery Charging

More information

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Your new LM controller is a state-of-the art device which was developed in accordance with the latest CAP LM-series Solar charge controller User Manual Thank you very much for buying this CAP product. Please read the instructions carefully and thoroughly before using the products. Your new LM controller

More information

ActiveLED Solar and DC Systems

ActiveLED Solar and DC Systems ActiveLED Solar and DC Systems By Klaus Bollmann June 2016 1 P age Rationale ActiveLED, a division of Ringdale Instruments, has a uniquely modular approach to providing solar applications for lighting

More information

BS20 BATTERY CHARGER For lead-acid batteries

BS20 BATTERY CHARGER For lead-acid batteries BS20 BATTERY CHARGER For lead-acid batteries User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries. THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

BATTERY MONITORING SYSTEM RPB-24

BATTERY MONITORING SYSTEM RPB-24 BATTERY MONITORING SYSTEM RPB-24 MEASUREMENT AND MONITORING DEVICES AC & DC POWER SOLUTIONS TRACTION CONVERTERS DESIGNATION Battery Monitoring System RPB-24 is a microprocessor controlled device, which

More information

UPS Multi Power 1-28 x 42 kw up to 1MW

UPS Multi Power 1-28 x 42 kw up to 1MW sectors and applications such as healthcare, power generation, social networking, telecommunications, commerce and education. Subsequently, any activities and equipment related to data storage, processing

More information

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software

More information

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring. Battery chargers Inverter-chargers Battery monitoring Engineered power Inverters Battery splitters Battery separators MPPT solar charge controllers DC/DC converters SWISS made power Company Studer Innotec

More information

The Traveler Series: Adventurer

The Traveler Series: Adventurer The Traveler Series: Adventurer RENOGY 30A Flush Mount Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.2 Important Safety Instructions Please save these instructions.

More information

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah DIAGNOSTIC POWER SUPPLY WSC 720 user guide 12 V/24 V lead acid batteries 40-500 ah gb 1 Thank you for choosing this charger from Exide Technologies Your WSC720 is a quality product from Exide Technologies.

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries USER GUIDE Battery Charger Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries Please read this user guide carefully before using the charger Use protective eyewear when handling batteries

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing

More information

World Class Charging Systems. TEBETRON expert. Intelligent charging systems for traction batteries

World Class Charging Systems. TEBETRON expert. Intelligent charging systems for traction batteries World Class Charging Systems Intelligent charging systems for traction batteries 2 BENNING World Class Charging Systems Intelligent charging systems The series is a modern charging system, which combines

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

Dismantling the Myths of the Ionic Charge Profiles

Dismantling the Myths of the Ionic Charge Profiles Introduction Dismantling the Myths of the Ionic Charge Profiles By: Nasser Kutkut, PhD, DBA Advanced Charging Technologies Inc. Lead acid batteries were first invented more than 150 years ago, and since

More information

Hydraulic Valves «DSV»

Hydraulic Valves «DSV» Hydraulic Valves «DSV» Edition 09 01 Hydraulic Valves «DSV» Table of contents General information Integrated electronics amplifier and controller «DSV»...1.13-75 Product over-view and/or data sheets Proportional

More information

Analog input module. Brief description. Page 1/8. Data Sheet

Analog input module. Brief description. Page 1/8. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings Safety and use instructions LifeSpeed iq TM - 3-phase chargers ENGLISH SAFETY INSTRUCTIONS GOALS OF THIS MANUAL This manual is aimed at any authorized personnel wanting to use a 3-phase LifeSpeed iq TM

More information

Mia Sylvester Technical Sales Advisor Fronius UK FRONIUS PV STORAGE SOLUTION TRAINING

Mia Sylvester Technical Sales Advisor Fronius UK FRONIUS PV STORAGE SOLUTION TRAINING Mia Sylvester Technical Sales Advisor Fronius UK FRONIUS PV STORAGE SOLUTION TRAINING AGENDA / The Fronius Energy Package Design / Operation Modes / Fronius Symo Hybrid / Fronius Smart Meter / Fronius

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in this instruction manual & on the battery charger. This

More information

2012 Battery Chargers Program

2012 Battery Chargers Program 2012 Battery Chargers Program www.bs-battery.com SPECIFICATIONS P/No. BA 10 BS 20 BS 40 BS 80 BS 160 BS 210 BK 10 Type: Automatic Smart Pro-Smart Bank Input Range: 100-240 Vac 100-240 Vac 100-240 Vac 100-240

More information

GFS - New Charging Technology

GFS - New Charging Technology GFS - New Charging Technology The new GFS-Chargers feature the highest flexibility and the simplest usability. They set new standards regarding the quantity and extent of retrievable data. Pulse-chargers

More information

XTRA-N SERIES. New MPPT Solar Charge Controller. Product models XTRA1206N/XTRA2206N XTRA1210N/XTRA2210N XTRA3210N/XTRA4210N.

XTRA-N SERIES. New MPPT Solar Charge Controller. Product models XTRA1206N/XTRA2206N XTRA1210N/XTRA2210N XTRA3210N/XTRA4210N. -N SERIES New MPPT Solar Charge Controller Product models 1206N/2206N 1210N/2210N 3210N/4210N Product portfolio The -N series integrate the latest design philosophy, as the main part which is the solar

More information

EV Display User Guide

EV Display User Guide EV Display User Guide CleanPowerAuto LLC Brief Description: EV Display is designed to track battery state of charge and other related data in battery powered Electric Vehicle. EV Display is primarily designed

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

User Manual. NiMH/NiCd Charger N, N, N, N Series

User Manual. NiMH/NiCd Charger N, N, N, N Series User Manual NiMH/NiCd Charger 452115-N, 452215-N, 452116-N, 452415-N Series READ THESE INSTRUCTIONS BEFORE USING THE CHARGER This battery charger is only designed for indoor use and should not come into

More information

Language specific user manuals are available on

Language specific user manuals are available on User Manual WEB Charger for LiFePO 4 Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d

More information

DART Charger Product Description, Information and Specification

DART Charger Product Description, Information and Specification g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)

More information

Remote Condition Monitoring

Remote Condition Monitoring Remote Condition Monitoring Track Circuit / Axle Counter Battery HMU Point Machine Energy Information System (EIS) Point Machine HEALTH MONITORING UNIT Point Machine Health Monitoring Unit (PHMU) reduces

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester Charge & Testing Integrated Electronic Solutions Connect Multimediality The new ADELSystem platform communication ADELBus

More information

Phase Modular Finally the benefits of Modular ups are for all

Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 The MUST 30/120 is an uninteruptible power supply, three phase input/ output, ranging from 15 kva to 120 kva

More information

C3 Operating Instructions

C3 Operating Instructions Version 3.1 Stand 09.2014 Robert Bosch (Australia) Pty. Ltd. 1555 Centre Road Clayton, Victoria 3168 C3 Operating Instructions For further information please contact Bosch at: Australia 1300 30 70 40 www.boschautoparts.com.au

More information

Industrial Power Supplies

Industrial Power Supplies , Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with

More information

INTRODUCTION. Specifications. Operating voltage range:

INTRODUCTION. Specifications. Operating voltage range: INTRODUCTION INTRODUCTION Thank you for purchasing the EcoPower Electron 65 AC Charger. This product is a fast charger with a high performance microprocessor and specialized operating software. Please

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL 10A / 15A / 20A Solar Charge Controller PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL Dear Customer, Thank you very much for choosing our product. This manual contains important information about

More information

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Special Specification 6058 Battery Back-Up System for Signal Cabinets Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd/imh 250 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 50 250 V ow

More information

Intelligent Lift Control Valve with Electronic Card

Intelligent Lift Control Valve with Electronic Card Intelligent Lift Control Valve with Electronic Card Q max = 500 l/min, p max = 80 bar Leak-free, two-stage, electronically controlled, without frequency control i50 and i500 Information lift-control valve

More information

Tachometer (RPM Feedback) General

Tachometer (RPM Feedback) General Tachometer (RPM Feedback) General The force of magnetic fields interacting drives all electric motors. How the magnetic field is created on the moving rotor determines the type of control required on the

More information

The Traveler Series TM : Adventurer

The Traveler Series TM : Adventurer The Traveler Series TM : Adventurer 30A PWM Flush Mount Charge Controller w/ LCD Display 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 3.4 Important Safety Instructions Please save

More information

User manual for intelligent pulse battery charger AP-3000, 12V 135A, 24V 100A, 36V 75A, 48V 50A

User manual for intelligent pulse battery charger AP-3000, 12V 135A, 24V 100A, 36V 75A, 48V 50A Eyra elektronika d.o.o., Gabrje pri Stični 45,1295 Ivančna Gorica,, info@eyra-elektronika.si User manual for intelligent pulse battery charger AP-3000, 12V 135A, 24V 100A, 36V 75A, 48V 50A Properties:

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Automatic DC Power Supply/Battery Charger

Automatic DC Power Supply/Battery Charger Automatic DC Power Supply/Battery Charger PATENTED U.S. 9,270,140; 9,385,556; 9,413,186; 9,509,164 NEW in 2015: Field selectable AC input voltage in high-powered units Automatic battery commissioning mode

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries DESIGNED FOR WORKSHOPS AND WAREHOUSES User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries. THIS MANUAL

More information

LIST OF CONTENTS TESTING EQUIPMENT

LIST OF CONTENTS TESTING EQUIPMENT LIST OF CONTENTS TESTING EQUIPMENT Batterytester BBT 305 Batterytester BBT 605 Batterytester BT 301 Batterytester Milton Batterytester Milton Digital Batterytester 500 A2 Forrex tester 12V 420A HSP Printer

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

trak power premium charge

trak power premium charge premium charge Innovative charging technology Made in Germany Motive Power Systems Reserve Power Systems Special Power Systems Service Your benefits with HOPPECKE High frequency charging technique Energy-saving

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

3000W HF/PFC Battery Charger

3000W HF/PFC Battery Charger 3000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments > 0.98 Power

More information