MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Size: px
Start display at page:

Download "MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL"

Transcription

1 MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG. CO M Rev A PO BOX 151 WEBB CITY, MO /15 PH (417) FAX (417) Technical Support: Ph: techsupport@cardet.com

2 2

3 INTRODUCTION Thank you for purchasing our Detecto Model WPS12 Waterproof Digital Portion Scale. This manual will guide you through installation, and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference. FCC COMPLIANCE STATEMENT This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference. You may find the booklet "How to Identify & Resolve Radio-TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C The stock number is All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. Serial Number Date of Purchase Purchased Form RETAIN THIS INFORMATION FOR FUTURE USE TABLE OF CONTENTS Installation Unpacking.. 1 Power Supply Battery Pack Battery Charging... 1 Low Battery Display Annunciators Key Functions Operation Configuration... 5 Gravity Compensation... 6 Display Messages... 7 Care and Maintenance... 7 SPECIFICATIONS Weight Display: 5Digits, Height 24.3mm, HTN Dimensions: Platform Size: Zero: Power: Tare: Temperature Operation: Storage: Capacity: Keys: Features: PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "NOTIFICATION" symbols: IMPORTANT 187mm x 246mm x 57mm 184 mm x 172mm Established on power up routine and maintained by auto-zero circuitry. AC adapter: 120 VAC input 9v, 100mA output Battery: Ni-MH rechargeable 4.8 VDC 1800 ma 100% of full scale capacity 40 to 105 F (5 to 40 C) 140 F (60 C) Maximum 12lb x 0.1oz, 12lb x 1/8 oz, 12lb x lb, 192 oz x 0.05 oz, 192 oz x 1/8 oz, 5500g x 1 g ON/OFF, TARE, UNITS/Back Light, SET IP67 ELECTRICAL WARNING 1

4 2

5 INSTALLATION UNPACKING Before beginning installation of your scale, make certain the instrument has been received in good condition. When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit. 1. Remove the scale from the shipping carton and inspect it for any signs of damage. 2. Plug-in the adapter to use the scale and begin charging the battery pack. Refer to the POWER SUPPLY or BATTERY PACK sections of this manual for more instruction. 3. Place the scale on a flat level surface, such as a table or bench. 4. The scale is now ready for use. POWER SUPPLY To apply power to the scale using the supplied power supply, insert the plug from the power supply cable into the power jack on the side of the scale and then plug power supply into the proper electrical outlet. The scale is now ready for operation. BATTERY PACK The scale uses a 4.8 VDC, 1800 ma built-in rechargeable battery pack. The WPS12 can operate for up to 80 hours of continuous use with a fully charged battery pack. BATTERY CHARGING To recharge the battery pack, the power supply must be connected to an AC power outlet and plugged into the scale. It will take approximately 5 hours to fully recharge the battery pack in the scale. While the batteries are charging the WPS12 can still be operated. Note that charging the battery pack for more than 12 hours will not damage it. LOW BATTERY When the battery pack is near the point it needs to be recharged, a low battery indicator on the display will turn on. If the battery voltage drops too low for accurate weighing, the scale will automatically shut off and you will be unable to turn it back on. When the low battery indicator is displayed, the operator should plug the power supply into the scale and then into the proper electrical wall outlet. The scale will begin charging the battery pack. 1

6 DISPLAY ANNUNCIATORS The annunciators are turned on to indicate that the scale display is in the mode corresponding to the annunciator label or that the status indicated by the label is active. The O annunciator is turned on when the weight display is stable. lb The lb annunciator is turned on to indicate that the displayed weight is in pounds. oz The oz annunciator is turned on to indicate that the displayed weight is in ounces. lb oz Both the lb and oz annunciators are turned on to indicate that the displayed weight is in pounds and ounces. g The g annunciator is turned on to indicate that the displayed weight is in grams. The low battery annunciator is used with the battery operation. It will turn on to indicate that the batteries will soon need to be recharged. Low limit setting annunciator High limit setting annunciator 2

7 KEY FUNCTIONS UNITS / 1. Press to change the weighing units to the alternate units of measurement (if selected during configuration of the scale). 2. Press and hold three (3) seconds to turn display back light on or off.- TARE 1. Press to reset the displayed weight to zero up to 100% of the scale capacity. ON/OFF 1. Press and release to turn on scale. 2. Press and release to turn the scale off. 3

8 OPERATION TURN THE SCALE ON Press the ON/OFF key to turn the scale on. The scale will display all display segments then change to zero weight. SELECT THE WEIGHING UNIT Press the UNITS key to alternate between the selected weighing units. NOTE: Multiple weighing units must be enabled during configuration for this function to be operational. WEIGH Place the item to be weighed on the scale tray. Scale will display item weight. TO RE-ZERO THE WEIGHT DISPLAY To Zero or Tare the weight display, press the TARE key and continue. The scale will re-zero / TARE until the full capacity is reached. TARE To weigh ingredients in a container you must first TARE the weight of the container so that only the net weight of the ingredient is displayed. 1. Place empty container on scale platform while scale is OFF 2. Turn scale on. Display will show zero weight. 3. Add ingredient to container. Scale will display weight of ingredient. 4. To weigh additional ingredients, press TARE before adding each ingredient. 5. To display the total weight of ingredients press the SET and TARE keys at the same time. 6. Note that upon removing the container and ingredients the scale will display a negative weight. Press the TARE key to return the scale to zero. HIGH / LOW WEIGHT CHECKING The scale may be set to alert you when either over or under a set limit. 1. Press and hold the TARE key for 3 seconds. The scale will beep and display the low weight annunciator 2. Place weight equal to low weight limit on scale and press SET. Scale will beep indicating low limit is set. Scale will display the high weight annunciator. 3. Add weight to scale until weight is equal to desired high weight limit. Press SET. Scale will beep indicating high limit is set. Remove weight from scale. The scale will now beep and display will indicate if item placed on scale is over or under the set limits. To clear the HIGH / LOW settings, press SET and TARE keys at the same time The membrane keyboard is not to be operated with pointed objects (pencils, pens, fingernails, etc.). Damage to keyboard resulting from this practice will NOT be covered under warranty. 4

9 CONFIGURATION The Scale has been pre-configured at the factory and should not require configuration for use in most applications. In the event that the factory settings do not meet the requirements of your application, the following describes the steps to configure the scale. TO BEGIN CONFIGURATION: 1. Press the ON/OFF key to turn on the scale. 2. Press and hold the SET key for 3 seconds. When the display shows, release the SET key to enter the Configuration mode. The display will change to show. WEIGHING UNITS To select lb/oz (pounds/ounce) weighing units (12 lb x 0.1 oz): 1. With the display showing, press the SET key. The display will change to show and the status ( or ). 2. Press the UNIT key to toggle between: Enable (display will change to ) or Disable (display will change to ). 3. Press the SET key. 4. Repeat above steps for each weighing unit mode : g = grams (5500g x 1 g) lb oz = pound ounces (12 lb x 0.1 oz) lb oz 1/8 = pound / 1/8 ounces (12 lb x 1/8 oz) lb = pounds only (12 lb x lb) oz = ounces (192 oz x 0.05 oz) oz 1/8 = 1/8 ounces (192 oz x 1/8 oz) 5. The display will return to. 6. Press UNIT key to proceed to AUTOMATIC SHUTOFF AUTOMATIC SHUTOFF 1. The display will change to AOFF. 2. Press the SET key to begin selection of the automatic shut-off time (in seconds). 3. Press the UNIT key to toggle through the selections,,,,, or. 4. When the desired time or Off is displayed, press the SET key. 5. The display will return to. 6. Press UNIT key to proceed to GRAVITY COMPENSATION. 5

10 GRAVITY COMPENSATION 1. With the display showing : CONFIGURATION, CONT. To Enable the Gravity Compensation mode, press the SET key. The display will change to (use the factory set value of 9.797). To Disable the Gravity Compensation mode, press the UNIT key. The display will change to (use the value obtained from the factory Tech Support). 2. Press the SET key again. The display will change to show. 3. Press the UNIT key. The display will change to show. 4. Press the SET key to save the settings and reset the scale. 5. Setup is complete. GRAVITY COMPENSATION The Gravity Compensation for your scale has been pre-configured at the factory and should not require changing in most locations. In the event that the factory settings do not meet the requirements of your location, contact the factory Tech Support for the value for your location. With enabled in the function setting of the Configuration mode, the scale will use the factory set value of for the Gravity Compensation. If the is disabled, the scale will use the value obtained from the factory Tech Support and entered by the operator for the Gravity Compensation. To change the Gravity Compensation value: 1. Press and hold the UNIT key while pressing the ON/OFF key to turn on the scale and enter Gravity Compensation mode, the display will show (or the current value). 2. Press the UNIT key to increase the value or TARE key to decrease the value to achieve the desired value. 3. Press the SET key to confirm the entered gravity and return the scale to the normal operating mode. CALIBRATION PROCEDURE 1. While the scale is off, press and hold the ON/OFF key. 2. Once all display segments are on, release the ON/OFF key and immediately and press the UNIT key three (3) times. 3. The scale will show , and finally show the counts of zero. 4. Press the SET key. The scale will show 0g and then go back to the counts. 5. Place a 5.5 kg test weight on the scale and then press the SET key. 6. The scale will show 5500g, and change to show CAL, and then automatically turn off. 7. Remove the test weight from the scale. 8. The scale is ready for normal operation. 6

11 DISPLAY MESSAGES DISPLAY MEANING Low battery indication E 2 prom Error Over capacity CARE AND MAINTENANCE The heart of the WPS12 Waterproof Digital Portion Scale is a precision load cell located in the center of the scale base. It will provide accurate operation indefinitely if protected against overload of scale capacity, dropping items on scale, or other extreme shock. DO NOT use acetone, thinner or other volatile solvents for cleaning. DO NOT expose scale to direct sunlight or temperature extremes. DO NOT place scale in front of heating/cooling vents. DO clean the scale with a damp soft cloth and mild non-abrasive detergent. DO clean the scale by submerging in dishpan and using mild non-abrasive detergent. NOTE: Before submerging scale in dishpan, make sure power jack cover on side of scale is completely inserted, battery pack cover on bottom of scale is installed and water temperature does not exceed 140 F (60 C). DO remove AC power before cleaning with a damp cloth or submerging scale in dishpan. DO provide clean AC power and adequate protection against lightning damage. DO keep the surroundings clear to provide clean and adequate air circulation. DO NOT PLACE SCALE IN COMMERCIAL DISHWASHER TO CLEAN! 7

12 8

MODEL PS-4 DIGITAL PORTION SCALE

MODEL PS-4 DIGITAL PORTION SCALE MODEL PS-4 DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG. CO. 8528-M317-O1 Rev A 203 E. Daugherty, Webb City, MO 64870 USA 07/05 Ph: 417-673-4631 Fax: 417-673-2153 www.detectoscale.com Technical

More information

Price Computing Scale D Series Operation Manual

Price Computing Scale D Series Operation Manual This Document is Hosted by: www.oldwillknottscales.com Price Computing Scale D Series Operation Manual Cardinal Scale Manufacturing Co. 8529-M400-O1 Rev. A PO BOX 151 WEBB CITY, MO 64870 04/13 PH (417)

More information

Patient Lift Scale Indicator Owner s Manual

Patient Lift Scale Indicator Owner s Manual Patient Lift Scale Indicator Owner s Manual Item # 13046 INTRODUCTION Thank you for purchasing the Model PL600DM Patient Lift Scale Indicator. It has been manufactured with quality and reliability. This

More information

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions CARDINAL SCALE MFG. CO. 8525-M041-O1 Rev H PO BOX 151 WEBB CITY, MO 64870 Printed in USA 09/04 PH (417) 673-4631 FAX (417)

More information

Price Computing Scale DS Series Operation Manual

Price Computing Scale DS Series Operation Manual Price Computing Scale DS Series Operation Manual Cardinal Scale Manufacturing Co. 8529-M635-01 Rev B PO BOX 151 WEBB CITY, MO 64870 Printed in USA 04/09 PH (417) 673-4631 - FAX (417) 673-5001 www.detectoscale.com

More information

PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual

PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual PEDIATRIC SCALE Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual CARDINAL SCALE MFG. CO. 8525-M178-O1 Rev F PO BOX 151 v WEBB CITY, MO 64870 Printed in USA 11/07 PH (417) 673-4631 v FAX (417) 673-5001

More information

DIGITAL Pediatric Scale Models 8435 & 8435KG Owner s Manual

DIGITAL Pediatric Scale Models 8435 & 8435KG Owner s Manual DIGITAL Pediatric Scale Models 8435 & 8435KG Owner s Manual CARDINAL SCALE MFG. CO. 8525-M316-O1 Rev A 203 E. Daugherty, Webb City, MO 64870 USA Printed in USA 02/10 Ph: 417-673-4631 Fax: 417-673-2153

More information

DIGITAL PHYSICIAN Waist-High Scale. Eye-Level Scale. Model 6127 Series, 6129 Series and. Models 6337 and 6339 Operating Instructions

DIGITAL PHYSICIAN Waist-High Scale. Eye-Level Scale. Model 6127 Series, 6129 Series and. Models 6337 and 6339 Operating Instructions DIGITAL PHYSICIAN Waist-High Scale Model 6127 Series, 6129 Series and Eye-Level Scale Models 6337 and 6339 Operating Instructions CARDINAL SCALE MFG. CO. 8525-M310-O1 Rev C PO BOX 151 WEBB CITY, MO 64870

More information

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Model 850F CARDINAL SCALE MFG. CO. 0066-M176-O1 Rev J 203 E. Daugherty, Webb City, MO 64870 USA 11/14 Ph: 417-673-4631 Fax: 417-673-5001

More information

ELECTRONIC PHYSICIAN Waist-High Scale 6027 and 6029 Series Owner s Manual

ELECTRONIC PHYSICIAN Waist-High Scale 6027 and 6029 Series Owner s Manual ELECTRONIC PHYSICIAN Waist-High Scale 6027 and 6029 Series Owner s Manual CARDINAL SCALE MFG. CO. 0044-M078-O1 Re G PO BOX 151 WEBB CITY, MO 64870 Printed in USA 11/06 PH (417) 673-4631 FAX (417) 673-5001

More information

IB-400. Weighmobile. Owner's Manual

IB-400. Weighmobile. Owner's Manual IB-400 Weighmobile Owner's Manual CARDINAL SCALE MFG. CO. 0046-M023-O1 Rev I PO BOX 151 WEBB CITY, MO 64870 Printed in USA 05/00 PH 417-673-4631 FAX 417-673-5001 Web Site - http://www.detectoscale.com

More information

Digital Stand-On Sit-Down Scale Models 6868 & 6868KGEU Operating Instructions

Digital Stand-On Sit-Down Scale Models 6868 & 6868KGEU Operating Instructions Digital Stand-On Sit-Down Scale Models 6868 & 6868KGEU Operating Instructions CARDINAL SCALE MFG. CO. 0065-M502-O1 Rev C PO BOX 151 WEBB CITY, MO 64870 Printed in USA 05/13 PH (417) 673-4631 FAX (417)

More information

PD100 PD200 PD300 PD300DHR

PD100 PD200 PD300 PD300DHR ProDoc Series Digital Physician Scale PD100 PD200 PD300 PD300DHR (Digital Height Rod) and PD300MHR (Mechanical Height Rod) Owner s Manual QuickMedical - Authorized Distributor 0044-M340-O1 Rev A PO Box

More information

Digital Stand-On Sit-Down Scale Models 6876 & 6876KGEU Operating Instructions

Digital Stand-On Sit-Down Scale Models 6876 & 6876KGEU Operating Instructions Digital Stand-On Sit-Down Scale Models 6876 & 6876KGEU Operating Instructions CARDINAL SCALE MFG. CO. 0065-M481-O1 Rev C PO BOX 151 WEBB CITY, MO 64870 Printed in USA 05/13 PH (417) 673-4631 FAX (417)

More information

DIGITAL PHYSICIAN Eye-Level Scale

DIGITAL PHYSICIAN Eye-Level Scale This Document is Hosted by: www.oldwillknottscales.com DIGITAL PHYSICIAN Eye-Level Scale Model 6437 Series Operating Instructions CARDINAL SCALE MFG. CO. 0033-M114-O1 Rev F PO BOX 151 WEBB CITY, MO 64870

More information

PD100 PD200 PD300 PD300DHR

PD100 PD200 PD300 PD300DHR ProDoc Series Digital Physician Scale PD100 PD200 PD300 PD300DHR (Digital Height Rod) and PD300MHR (Mechanical Height Rod) Owner s Manual CARDINAL SCALE MFG. CO. 0044-M340-O1 Rev C PO Box 151 Webb City,

More information

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Cardinal DETECTO PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual CARDINAL SCALE MFG. CO. PO BOX 151, WEBB CITY, MO 64870 0066-M176-O1 Rev H 10/06 417-673-4631 www.cardinalscale.com Printed

More information

DIGITAL PHYSICIAN Waist-High Scale

DIGITAL PHYSICIAN Waist-High Scale DIGITAL PHYSICIAN Waist-High Scale Model 8430 Series Operating Instructions CARDINAL SCALE MFG. CO. 8525-M041-O1 Rev K PO BOX 151 WEBB CITY, MO 64870 Printed in USA 10/12 PH (417) 673-4631 FAX (417) 673-5001

More information

SONARIS Sonar Stadiometer Owner s Manual

SONARIS Sonar Stadiometer Owner s Manual SONARIS Sonar Stadiometer Owner s Manual 1 2 INTRODUCTION Thank you for purchasing our Detecto SONARIS Sonar Stadiometer. It has been manufactured with quality and reliability and has been tested before

More information

Digital Stand-On Sit-Down Scale Models 6868/6868KGEU Operating Instructions

Digital Stand-On Sit-Down Scale Models 6868/6868KGEU Operating Instructions Digital Stand-On Sit-Down Scale Models 6868/6868KGEU Operating Instructions 0065-M502-O1 Rev E 203 E. Daugherty, Webb City, MO 64870 USA Printed in USA 12/16 Ph: 417-673-4631 Fax: 417-673-2153 www.detecto.com

More information

Waist-High Digital Bariatric Scale Model 685X Series Operating Instructions

Waist-High Digital Bariatric Scale Model 685X Series Operating Instructions Waist-High Digital Bariatric Scale Model 685X Series Operating Instructions CARDINAL SCALE MFG. CO. 1930-M458-O1 Rev F 203 E. Daugherty, Webb City, MO 64870 USA Printed in USA 03/15 Ph: 417-673-4631 Fax:

More information

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE This document hosted by: www.oldwillknottscales.com HS SERIES ELECTRONIC HANGING SCALE CONTENTS 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION OPERATION MANUAL 3. INSTRUCTIONS FOR USE 4. HOW

More information

IB-600. Weighmobile. Owner's Manual

IB-600. Weighmobile. Owner's Manual IB-600 Weighmobile Owner's Manual CARDINAL SCALE MFG. CO. 0046-M264-O1 Rev D PO BOX 151 WEBB CITY, MO 64870 Printed in USA 05/00 PH 417-673-4631 FAX 417-673-5001 Web Site - http://www.detectoscale.com

More information

7550 Fold-up Stationary Wheelchair Scale Installation and Operation Manual

7550 Fold-up Stationary Wheelchair Scale Installation and Operation Manual 7550 Fold-up Stationary Wheelchair Scale Installation and Operation Manual CARDINAL SCALE MFG. CO. PO Box 151 Webb City, MO 64870 0065-0647-0M Rev A Ph: 417-673-4631 Fax: 417-673-5001 Printed in USA 11/13

More information

Model DS7060 Handrail Scale. User Manual

Model DS7060 Handrail Scale. User Manual Model DS7060 Handrail Scale User Manual Doran Scales, Inc. 1315 Paramount Pkwy Batavia, IL 60510 USA 1-800-264-4107 www.doranmedical.com MAN0302 Revision 0.0 TNW 2/20/2013 Section 1. Unpacking and Installation...

More information

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice. Digital Scale Revision 1.0 August 17, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702 Fax

More information

SPC Series. Digital Scale. Operation Manual

SPC Series. Digital Scale. Operation Manual SPC Series Digital Scale Operation Manual Revision 1.0 August 17, 2000 ! WARNING Use only the AC adapter which comes with the scale. Other adapters may cause damage. Internal service to this product should

More information

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy: π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature

More information

Compact Scales. Software Revision V1.25 & above

Compact Scales. Software Revision V1.25 & above Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:

More information

Adam Equipment CPW COMPACT SCALE

Adam Equipment CPW COMPACT SCALE Adam Equipment CPW COMPACT SCALE ADAM EQUIPMENT CO. LTD. pn. 3935 Rev. D, November 2002 INTRODUCTION The CPW Compact Scales are available in 4 models, with capacities from 25kg to 150kg. The scales are

More information

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08 USER S MANUAL G SERIES USER S MANUAL Ref.49-MG000EN08 Index USER S MANUAL 1. DESCRIPTION OF THE SERIE G SCALE... 1 1.1. KEYBOARD...1 2. INTRODUCTION... 2 2.1. GENERAL SPECIFICATIONS...2 2.2. OPERATIONAL

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

SSP-Series Portable Balances Operation Manual

SSP-Series Portable Balances Operation Manual SSP-Series Portable Balances Operation Manual TABLE OF CONTENTS SAFETY PRECAUTIONS.. 1 GETTING STARED... 1 INSTALLATION & SET-UP 2 POWER CONNECTION & BATTERY OPERATION... 2 LEVELING... 3 CALIBRATION...

More information

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS NGW & HGW SERIES HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE CONTENTS CAUTIONS 1. INSTALLATION 2. SPECIFICATIONS OPERATION MANUAL 3. KEYBOARD LAYOUT AND DESCRIPTION 4. INITIAL SETUP PLEASE READ THIS MANUAL

More information

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002 Adam Equipment QT SERIES ADAM EQUIPMENT CO. LTD. pn. 3938 Rev. D1, July 2002 Adam Equipment Co. Ltd. 2002 Adam Equipment Co. Ltd. 2002 FEATURES Auto shut off Auto zero tracking Auto backlight (optional)

More information

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004 Adam Equipment MIW-20 BABY SCALE ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004 Adam Equipment Company 2004 Adam Equipment Company 2004 CONTENTS 1.0 INTRODUCTION... 2 2.0 TECHNICAL SPECIFICATIONS...

More information

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS This document hosted by: www.oldwillknottscales.com BM SERIES CONTENTS BENCH/FLOOR SCALE 1 INSTALLATION OPERATION MANUAL 2 SPECIFICATIONS PLEASE READ THIS INSTRUCTION MANUAL VERY CAREFULLY BEFORE ATTEMPTING

More information

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS CONTENTS SAC SERIES TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE 1. INSTALLATION 2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS OPERATION

More information

Ohaus ES Series Bench Scale

Ohaus ES Series Bench Scale Ohaus ES Series Bench Scale INSTRUCTION MANUAL 1 2 DECLARATION OF CONFORMITY Ohaus Corporation, 19A Chapin Road, P.O. Box 2033, Pine Brook, NJ, 07058, USA We, Ohaus Corporation, declare under our sole

More information

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013) Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when

More information

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011) Adam Equipment WBW & WBW-M SERIES (P.N. 3036610540, Revision A2, November 2011) Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally friendly packaging

More information

Valor 2000 Series Instruction Manual

Valor 2000 Series Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TM Valor 2000 Series Instruction Manual Valor 2000 Series Scales EN-1 1. INTRODUCTION

More information

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale KILOTECH KWD 500 Water tight Portion/Weighing Scale Operation Manual Version 1.0 Last Modified: Jan 2006 1 Industrial Weighing Systems 9 Richmond St. Picton, ON Canada K0K 2T0 Ph: 613-786-0016 Cell: 613-921-0397

More information

AP30 MkII Postal Scale INSTRUCTION MANUAL

AP30 MkII Postal Scale INSTRUCTION MANUAL AP30 MkII Postal Scale INSTRUCTION MANUAL Dual Range 2kg x 0.001kg / 30kg x 0.01kg AP30MkII OZIM v 1d Contents 1. Compliance...1 1.1 Compliance with C Tick...1 1.2 Compliance with National Standards Commission...1

More information

Solar mosquito killer

Solar mosquito killer Solar mosquito killer Model 96415 Assembly And Operation Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious

More information

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

NPS Series. Pallet Jack Scale Operator s Guide (V1611) NPS Series Pallet Jack Scale Operator s Guide (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623)

More information

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973) SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D ST400D Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D

More information

Virtual Measurements & Control. VC210 Operators Manual

Virtual Measurements & Control. VC210 Operators Manual Virtual Measurements & Control VC210 Operators Manual Safety Notice 2 Technical Specification 3 Features 3 Theory of Operation 4 Operation 4 Enunciators 4 Buttons 5 Power Down Timer and Buzzer Setting

More information

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T Model GS30 Model #: Serial #: Model GS30T NTEP Approved Meets NIST Handbook 44 Criteria Legal for Trade Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T For Service on Your Scale:

More information

User Guide. Digital Shipping Scale S150

User Guide. Digital Shipping Scale S150 User Guide Digital Shipping Scale S150 2012 Sanford, L.P. All rights reserved. Revised 3/12. No part of this document or the software may be reproduced or transmitted in any form or by any means or translated

More information

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g) American Weigh Scales SC-Series User Manual SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 SC-Series Manual Thank

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

MS300 P latform S cale

MS300 P latform S cale 3kg x.1kg/66lb x.2lb HOLD UNITS kg/ ON-OFF ZERO TARE T I MS3 MS3 P latform S cale User Instructions E NG L IS H 7613-578 Issue 1 27.4.23 Salter Brecknell Weighing 22. All rights reserved. The information

More information

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale 3400KL / 3400KG / 3400KG-C 3401KL User Instructions PELSTAR, LLC 9500 West 55 th St. McCook, IL 60525-7110 USA www.homscales.com

More information

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2. American Weigh Scales SG-300 User Manual SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 SG-300 Manual Thank you for purchasing the American Weigh SG-300 spoon

More information

Models XMC/XWS/XWT (-S) -XIS

Models XMC/XWS/XWT (-S) -XIS STANDARD BENCH SCALE OPERATION & SERVICE MANUAL Models XMC/XWS/XWT (-S) -XIS STANDARD BENCH SCALE www.mt.com/xpress 2 STANDARD BENCH SCALE ABOUT THIS MANUAL AND MT EXPRESS Thank you for purchasing an MT

More information

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 EDGE User Manual EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 EDGE-5K Thank you for purchasing the American Weigh EDGE- 5K digital kitchen scale. Please

More information

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

User Manual Industrial Power Storage System (ips) ips-m Series Battery System User Manual Industrial Power Storage System (ips) ips-m Series Battery System Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co., Ltd. All rights

More information

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability) MODEL TI-500 RF Series Digital Weight Indicator (with wireless weighing capability) User Manual Revision 1.4 July 6, 2018 Table of Contents OVERVIEW... 3 Scope of TI-500 RF Series... 3 BASIC OPERATION...

More information

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1. accurate around the world s i n c e 1 8 9 7 User s Guide EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR WB-40 Weigh Bars TS-700 WB Digital Indicator Guide version 1.3 USER S GUIDE Table of Contents

More information

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T Model GS30 Model #: Serial #: Model GS30T NTEP Approved Meets NIST Handbook 44 Criteria Legal for Trade Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T For Service on Your Scale:

More information

Catapult 1000 Series Instruction Manual

Catapult 1000 Series Instruction Manual TM Catapult 1000 Series Instruction Manual Catapult 1000 Series Scales EN-1 1. INTRODUCTION This manual contains installation, operation and maintenance instructions for the TM Catapult 1000 Series Scales.

More information

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 ECOWEIGH Series ECO-5K User Manual ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 ECO-5K Thank you for purchasing the American Weigh ECO- 5K digital kitchen

More information

Weighing Scale IDS-802. User Manual

Weighing Scale IDS-802. User Manual Weighing Scale IDS-802 User Manual A. MAIN SPECIFICATION Model: Capacity: Accuracy: Display: IDS-802 Weighing scale 3kgx0.1g,6kgx0.2g,15kgx0.5g,30kgx1g Grade III, n=30,000 Single 6 digits LCD with Blue

More information

Operating instructions Platform/floor scales

Operating instructions Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN

More information

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

uline.com

uline.com π H-1679 H-2331 PALLET TRUCK SCALE 1-800-295-5510 uline.com Avoid placing the scale in locations that may AFFECT accuracy: 1. Temperature extremes Do not place in direct sunlight or near air conditioning

More information

PORT-A-WEIGH CRANE SCALES

PORT-A-WEIGH CRANE SCALES MSI4260 PORT-A-WEIGH CRANE SCALES User Guide Quality Industrial Weighing and Force Measurement Equipment Measurement Systems International Page 2 MSI-4260 Port-A-Weigh User Guide TABLE OF CONTENTS Introduction...

More information

Quick Guide. brite Advanced Retail scale

Quick Guide. brite Advanced Retail scale Quick Guide brite Advanced Retail scale 2 METTLER TOLEDO Quick Guide brite Advanced Contents 1 Your new retail scale...4 1.1 Safety instructions...4 1.2 Further documents...4 1.3 Maintenance...4 1.4 Intended

More information

Premier Mobile Electric Lift Table Setup Manual

Premier Mobile Electric Lift Table Setup Manual Premier Mobile Electric Lift Table Setup Manual Table of Contents Installation... 2 Charging the Batteries................ 2 Optional Scale Features/Operation... 3 Troubleshooting... 4 Care & Cleaning....

More information

Marin Control Digital

Marin Control Digital Operation Manual Marin Control Digital Digital Meter for the measurement of Temperature, salinity and specific gravity in saltwater aquariums. Short instructions: ON OFF : Is used to turn the power on

More information

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge Instruction Manual Labnet Spectrafuge 16M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com Safety Precautions NEVER

More information

CITIZEN. series. Precision Balances

CITIZEN. series. Precision Balances CITIZEN CZ series Precision Balances - 9 - CZ [NTEP ] User s Guide Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS. 2 SECTION 3 INSTALLATION....3 SECTION 4 KEY DESCRIPTIONS.. 4 SECTION 5 OPERATION.....5

More information

Model 7400 OPERATOR MANUAL

Model 7400 OPERATOR MANUAL Model 7400 OPERATOR MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 1.0 MAN0198 10/3/2005 INTRODUCTION Introducing

More information

Model 700 Microarray Oven

Model 700 Microarray Oven www.scigene.com Model 700 Microarray Oven USER MANUAL Cat. #1070-00-1, 1070-00-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale, CA 94085 USA 408-733-7337

More information

Model 8000XL OPERATOR MANUAL

Model 8000XL OPERATOR MANUAL Model 8000XL OPERATOR MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 1.0 MAN0191 10/3/2005 INTRODUCTION

More information

Peninsula Folding Lift Table Manual

Peninsula Folding Lift Table Manual Peninsula Folding Lift Table Manual Table of Contents Pre-Installation......................... 2 Parts Identification... 2 Installation... 3 Installation with Scale Option... 4 Scale Features/Operation....

More information

Model WS-6020U Solar Station QUICK SETUP GUIDE

Model WS-6020U Solar Station QUICK SETUP GUIDE Model WS-6020U Solar Station QUICK SETUP GUIDE Solar-powered Transmitter: Remote transmission of outdoor temperature to the Solar Station by 915 MHz signals LCD displays the outdoor temperature data Recharge

More information

Midmark Electric Lift Table Manual

Midmark Electric Lift Table Manual Midmark Electric Lift Table Manual Table of Contents Pre-Installation......................... 2 Parts Identification... 2-3 Installation... 3 Installation with Scale Option... 4 Scale Features/Operation...

More information

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of

More information

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance TM ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance Scale Users Guide ISHTAA SCALES INC., INDIA www.ishtaascales.com 14 Content 1. Technical Data... 1 2. Installation... 2 3. Controls

More information

CED PRO II. High Precision Electronic Scale Instructions

CED PRO II. High Precision Electronic Scale Instructions CED PRO II High Precision Electronic Scale Instructions Phone - USA (610) 610-366-9752 (888) 628-3233 USA Fax: (610) 366-9680 Hong Kong (852) 28666802 CED PRO II SCALE INSTRUCTIONS Congratulations on your

More information

This page intentionally left blank. Cab Control 400

This page intentionally left blank. Cab Control 400 OPERATORS MANUAL DIGI-STAR 790 WEST ROCKWELL AVENUE FORT ATKINSON, WISCONSIN 53538 PHONE: (920) 563-1400 TECHNICAL SERVICE: (920) 563-9700 www.digi-star.com D3674-US Rev B June 30, 2005 This page intentionally

More information

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international

More information

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE Parking Alert Sensor SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE COMPLIANCE WITH FCC REGULATIONS This device complies

More information

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL Models XTCII ECONOMY COUNTING SCALE www.mt.com/xpress 2 ECONOMY COUNTING SCALE ABOUT THIS MANUAL AND MT EXPRESS Thank you for purchasing an MT Xpress product.

More information

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) EOW-LB100-PNUS2 Thank you for purchasing this product from Tabuchi Electric. Read this User s Manual carefully to ensure safe use of

More information

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY: π H-4564 PALLET TRUCK SCALE WITH PRINTER 1-800-295-5510 uline.com AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY: 1. Temperature extremes Do not place in direct sunlight or near air conditioning

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR PORTABLE SCOREBOARD MODEL MP-6300

OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR PORTABLE SCOREBOARD MODEL MP-6300 OPERATING INSTRUCTIONS AND SERVICE MANUAL OUTDOOR PORTABLE SCOREBOARD MODEL MP-6300 EFFECTIVE S.N.18,750, January, 2005 TABLE OF CONTENTS..PAGE 1. GENERAL INFORMATIO 3 1.1 DESCRIPTION 1.2 IDENTIFICATION

More information

COATING THICKNESS GAGE NOVOTEST TP-1

COATING THICKNESS GAGE NOVOTEST TP-1 COATING THICKNESS GAGE NOVOTEST TP-1 MANUAL 2015 All rights reserved. No part of this publication may be reproduced, stored in a retrieval, or transmitted in any form or by any means, electronic, mechanical,

More information

Operating manual Platform/floor scales

Operating manual Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating manual Platform/floor scales KERN / / EOS Type _B Type _B Type EOS_B Version 4.1 2017-04 GB Phone: +49-[0]7433-9933-0 Fax:

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL EFFECTIVE S.N.XXXX, JAN 1, 1994 TABLE OF CONTENTS 1. General Information 1.1 Description 1.2 Identification

More information

In accordance with the Gallagher policy of continuing development, design and specifications are subject to change without notice.

In accordance with the Gallagher policy of continuing development, design and specifications are subject to change without notice. PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagherams.com Copyright Gallagher Group Limited 2007. All rights reserved. Patents Pending. Weigh Scale

More information

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063 LIGHTBOLT MAX EXTENDABLE WORK LIGHT Model No. 4063 INSTRUCTION MANUAL MobilePower, LLC. Miami, FL www.mobilepower-us.com Customer Support: (800) 708-8550 customerservice@mobilepower-us.com BEFORE YOU USE

More information

MS-4200/4201/4202/4202L USER MANUAL

MS-4200/4201/4202/4202L USER MANUAL MS-4200/4201/4202/4202L USER MANUAL TABLE OF CONTENTS PREFACE... 2 GENERAL INFORMATION... 2 SAFETY INSTRUCTION... 2 ENVIROMENTAL... 3 CLEANING... 3 MAINTENANCE... 3 WEIGHING OPERATION... 3 WARRANTY-LIABILITY...

More information

F5 Platforms: FIPS Kit Installation MAN

F5 Platforms: FIPS Kit Installation MAN F5 Platforms: FIPS Kit Installation MAN-0647-00 Table of Contents Table of Contents About the FIPS kit...5 Supported platforms...5 Apply tamper evidence seals to F5 platforms...5 Legal Notices...9 3 Table

More information

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00 Easy Weigh OWNER S MANUAL MODEL: AC-100 ADVANCED COUNTING SCALE VER 1.00 TABLE OF CONTENTS SPECIFICATIONS... 1 NOMENCLATURE... 1 FUNCTION KEYS... 2 DISPLAY... 3 ACCURACY SPECIFICATIONS... 4 UNPACKING &

More information

Version /26/09

Version /26/09 Version 1.5 05/26/09 Documen Date Comments Sections t Version 1.2 02-27-07 Redesigned manual to be consistent with Triner Scale All format. 1.3 03-27-07 Redesigned Cover page image and Keyboard and Display

More information

Thermocouple Thermometer Models

Thermocouple Thermometer Models Thermocouple Thermometer Models 91100-00 (Type J) 91100-10 (Type K) 91100-20 (Type T) Cole-Parmer Instrument Company 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847)

More information

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1 OPERATIONS MANUAL M-520 Please take the time to read these instructions before starting to use the scales Page 1 Contents Power supply 3 Specifications 3 Maintenance and general care 3 Key functions 4

More information