Air flow management. Fan Filters Introduction
|
|
- Emery Anderson
- 5 years ago
- Views:
Transcription
1 6
2 Fan Filters Introduction Air management Increasingly often, the causes behind malfunctions or faults in electrical and electronic equipment housed in control panels or fitted as an integral part of a machine, are due to heat problems. In reality, the life span of components depends on the temperature and level of humidity inside the electrical cabinet. The normal recommended average operating temperature inside a cabinet is 35 C with relative humidity of no more than %. Fandis offers a wide range of solutions for efficiently disposing of dissipated heat from electrical components suitable for different applications. NATURAL CONVECTION The use of exhaust filter ensures the passage of air and the removal of heat in a natural manner. This solution can be considered for dissipating low level of heat in dusty environments. FORCED CONVECTION Forced ventilation is an inexpensive and efficient solution for preventing the formation of air pockets inside electrical cabinets. The best configuration includes fitting a fan filter to an exhaust filter. The fan filter positioned at the bottom of the cabinet, takes in and filters air from the outside (standard air ) while the exhaust filter at the top expels hot air. The pressure generated by the ventilation prevents unfiltered air from entering through holes or openings. 8 Fandis
3 Fan Filters Introduction FAN FILTERS An inverted air version - reverse - is also available (fan filter at top and exhaust filter at bottom). The system can be controlled by a thermostat that turns the fan on when high temperatures are detected. Hot air can also be expelled from the roof of the cabinet if, for instance, the sides of the cabinet are covered by obstacles, walls or by the sides of other cabinets. In a perfect configuration, an exhaust filter is positioned at the bottom of the cabinet. The lower pressure generated by the roof unit sucks in air from the outside through the exhaust filter to enhance internal air and the dissipation of heat. The use of a swivelling fan is an alternative solution for a better air circulation inside the electrical cabinet. This fan distributes heat to reduce the temperature, cools local hot spots and disperses cold air emitted by cooling units. Fandis 9
4 Fan Filters Introduction EMC shielding Electromagnetic compatibility, or EMC, relates to the unintentional generation or reception of electromagnetic energy that may lead to electromagnetic interference with a component or item of equipment. By incorporating EMC into electrical component design, electronics engineers can ensure the long-term stability and lifespan of multiple electrical components operating within a given space. The EMC shielding of an enclosure guarantees both limited radiated emissions and protects internal components from external sources of interference. Fandis EMC filters and fan filters are designed to prevent the weakening of the shielding effect in enclosures with a high level of protection, even with cutouts, and to maintain this status. 1 Fandis
5 Fan Filters Introduction FAN FILTERS Fan filters are a practical solution for removing heat from the cabinet. They channel filtered ambient air into the enclosure, expelling warm internal air through an exhaust filter or roof unit to reduce temperatures and protect electronic components from overheating. Fandis offers three different series of fan filters to better satisfy various cooling and ventilation requirements. FAN FILTERS FF SERIES TIME-SAVING INSTALLATION Quick tool-less mounting system with clips for 1 to 3.7mm thick plates QUICK CONNECTION Cage clamp free-tool wiring system IP55 AND TYPE 3R (OPTIONAL) Ideal for indoor or outdoor use in harsh industrial environments EMC-COMPATIBLE Metal shielding for electromagnetic protection SLIDE OPENING Easy replacement of the filter media without the need of tools COLORS Custom RAL colors subject to minimum order Details that make the difference Fandis 11
6 Fan Filters Introduction FPF SERIES FPF fan filters are the first series of Fandis filtering solutions for enclosures. These units have a low external profile to avoid obstruction and are easy to mount on standard panel cutouts with a fast snap-on assembly. An integrated sealing gasket also provides secure dust and water protection. QUICK INSTALLATION Snap-mounting system with elastic hooks EMC-COMPATIBLE Metal shielding for electromagnetic protection IP55 PROTECTION (OPTIONAL) Ideal for harsh ambient condition in industrial applications GF SERIES FAN FILTERS The GF fan filter range is characterized by an innovative mounting system with jacks, which accommodate both plastic and plate enclosures with thick wall applications. This series has the advantage of a fast outer installation, without extra drilling, and an easy filter replacement through the original hinged protection guard. FIXING WITH JACKS Patented system for thick wall applications in both plastic and plate enclosures (up to 16mm) HINGED OPENING Easy tool-less replacement of the filter media through the hinged protection guard 12 Fandis
7 FPF filter standard without fans FAN FILTERS A B C D E F G mm mm mm mm mm mm mm Kg FPF8KUG CE; curus; FPF12KUG CE; curus; FPF13KUG CE; curus; FPF15KUG CE; curus; FPFKUG CE; curus; G A B E F A C D F E 1 1 FPF12 FPF FPF13 FPF15 FPF Fandis 47
8 FPF EMC filter standard without fans ffelectromagnetic radiation protection A B C D E F G mm mm mm mm mm mm mm Kg FPF12KUGC CE; FPF13KUGC CE; FPF15KRGC CE; FPF15KUGC CE; FPFKRGC CE; FPFKUGC CE; G A B E F A C D F E 1 1 FPF12 FPF FPF13 FPF15 FPF Fandis
9 FPF8K fan filter 115/23 Va.c FAN FILTERS Current FPF8KU115B V a.c. 5/.115/.92 9./7. 23/3 42/62 33./ CE; curus; FPF8KU115BR V a.c. 5/.115/.92 9./7. 23/3 42/62 33./ CE; curus; FPF8KU23B V a.c. 5/.7/.55 1/8. 23/3 42/62 33./ CE; curus; FPF8KU23BR V a.c. 5/.7/.55 1/8. 23/3 42/62 32./ CE; curus; Standard / Reverse 65 5Hz 55 Hz FPF8KRG 5 FPF12KRG Fandis 49
10 FPF8KD fan filter 12/24 Vd.c Current V A W m 3 /h Pa db(a) Kg C FPF8KUD12B V d.c CE; FPF8KUD24B V d.c CE; curus; FPF8KUD24BR V d.c CE; curus; Standard Reverse FPF8KUG 24 FPF12KUG 22 FPF8K*D12/24B Air Flow [m3/h] FPF8KUG 35 FPF12KUG FPF8K*D24BR Fandis
11 FPF12K fan filter 24/115/23 Va.c FAN FILTERS Current FPF12KU115BE V a.c. 5/.21/.1 /18 57/61 66/73 46./ CE; curus; FPF12KU115BER V a.c. 5/.21/.1 /18 57/61 66/73 46./ CE; curus; FPF12KU23BE V a.c. 5/.125/.11 /19 57/61 66/73 46./ CE; curus; FPF12KU23BER V a.c. 5/.125/.11 /19 57/61 66/73 46./ CE; curus; FPF12KR24BE V a.c. 5/.81/.85 15/16 57/61 66/73 46./ CE; FPF12KU24BER V a.c. 5/.81/.85 15/16 57/61 66/73 46./ CE; Standard / Reverse Hz Hz FPF12KRG FPF13KRG Fandis 51
12 FPF12KD fan filter 24/48 Vd.c Current V A W m 3 /h Pa db(a) Kg C FPF12KUD24B V d.c CE; curus; FPF12KUD24BR V d.c CE; curus; FPF12KUD48B V d.c CE; Standard / Reverse Fan Filter FPF12KRG FPF13KRG Fandis
13 FPF13K fan filter 115/23 Va.c FAN FILTERS Current FPF13KU115BE V a.c. 5/./.1 22/ 1/135 84/1 46./ CE; curus; FPF13KU115BER V a.c. 5/./.1 22/ 1/135 84/1 46./ CE; curus; FPF13KU23BE V a.c. 5/.1/.9 23/21 1/135 84/1 46./ CE; curus; FPF13KU23BER V a.c. 5/.1/.9 23/21 1/135 84/1 46./ CE; curus; Standard / Reverse Hz Hz FPF13KRG FPF15KRG Fandis 53
14 FPF13KP fan filter 115/23 Va.c Current FPF13KPU115BE V a.c. 5/.21/.1 /18 11/1 68/82 46./ CE; curus; FPF13KPU115BER V a.c. 5/.21/.1 /18 11/1 68/82 46./ CE; curus; FPF13KPU23BE V a.c. 5/.125/.11 /19 11/1 68/82 46./ CE; curus; FPF13KPU23BER V a.c. 5/.125/.11 /19 11/1 68/82 46./ CE; curus; Standard / Reverse 9 5Hz Hz 7 FPF13KRG FPF15KRG Fandis
15 FPF13KPD fan filter 24 Vd.c FAN FILTERS Current V A W m 3 /h Pa db(a) Kg C FPF13KPRD24B V d.c CE; curus; FPF13KPRD24BR V d.c CE; curus; Standard / Reverse 7 5 Fan Filter FPF13KRG FPF15KRG Fandis 55
16 FPF15K fan filter 115/23 Va.c Current FPF15KU115BE V a.c. 5/.265/.274 3/3 2/27 111/134 5./ CE; curus; FPF15KU115BER V a.c. 5/.265/.274 3/3 2/27 111/134 5./ CE; curus; FPF15KU23BE V a.c. 5/.132/.13 29/29 2/27 111/134 5./ CE; curus; FPF15KU23BER V a.c. 5/.132/.13 29/29 2/27 111/134 5./ CE; curus; Standard / Reverse Hz 5 Hz FPF15KRG FPFKRG Fandis
17 FPF15KD fan filter 24/48 Vd.c FAN FILTERS Current V A W m 3 /h Pa db(a) Kg C FPF15KRD24BR V d.c CE; curus; FPF15KUD24B V d.c CE; curus; FPF15KUD48B V d.c CE; Standard / Reverse Fan Filter FPF15KRG FPFKRG Fandis 57
18 FPF15KG fan filter 115/23/ Va.c ffhigh performance Current FPF15KGR115BE V a.c. 5/./.65 58/7 3/ 1/1 66,/69, CE; curus; FPF15KGU115BE V a.c. 5/.54/.65 5/64 3/ 1/1 66,/69, CE; FPF15KGU115BER V a.c. 5/.54/.65 5/64 3/ 1/1 6/ CE; FPF15KGR23BE V a.c. 5/.3/.3 7/85 3/ 1/1 63.3/ CE; curus; FPF15KGU23BE-1 23 V a.c. 5/.3/ /87 3/ 1/1 63.3/ CE; 58 Fandis
19 FPF15KG fan filter 115/23/ Va.c Current FPF15KGU23BER-1 23 V a.c. 5/.3/ /87 3/ 1/1 63.3/ CE; FPF15KGUTBE-1 V a.c. 5/.1/.13 71/93 3/ 1/1 69.8/ CE; FPF15KGUTBER-1 V a.c. 5/.1/.13 71/93 3/ 1/1 69.8/ CE; FAN FILTERS 114 Standard / Reverse Hz 5 Hz FPF15KRG FPFKRG Fandis 59
20 FPF15KM fan filter 115/23 Va.c Current FPF15KMR115BER V a.c. 5/./.1 17/15 13/15 75/92 46./ CE; curus; FPF15KMU115BE V a.c. 5/./.1 17/15 13/15 75/92 46./ CE; curus; FPF15KMU23BE V a.c. 5/.1/.9 23/21 13/15 75/92 46./ CE; curus; FPF15KMU23BER V a.c. 5/.1/.9 23/21 13/15 75/92 46./ CE; curus; Standard / Reverse 1 9 5Hz Hz FPF15KRG FPFKRG Fandis
21 FPF15KP fan filter 115/23 Va.c FAN FILTERS Current FPF15KPR115BE V a.c. 5/.21/.1 /18 115/125 51/59 46./ CE; curus; FPF15KPR115BER V a.c. 5/.21/.1 /18 115/125 51/59 46./ CE; curus; FPF15KPU23BE V a.c. 5/.125/.11 /19 115/125 51/59 46./ CE; curus; FPF15KPU23BER V a.c. 5/.125/.11 /19 115/125 51/59 46./ CE; curus; Standard / Reverse Hz 5 Hz FPF15KRG FPFKRG Fandis 61
22 FPF15KPD fan filter 24/48 Vd.c Current V A W m 3 /h Pa db(a) Kg C FPF15KPRD24BR V d.c CE; curus; FPF15KPUD24B V d.c CE; curus; FPF15KPRD48B V d.c CE; FPF15KPRD48BR V d.c CE; Standard / Reverse 7 Fan Filters FPF15KRG FPFKRG Fandis
23 FPFK fan filter 115/23/ Va.c FAN FILTERS Current FPFKR115BE V a.c. 5/./.65 58/7 5/5 1/ / CE; curus; FPFKU115BE V a.c. 5/.54/.65 5/64 5/5 1/ / CE; FPFKU115BE V a.c. 5/./.65 58/7 5/5 1/186 66,/69, CE; curus; FPFKU115BER V a.c. 5/.54/.65 5/64 5/5 1/ / CE; FPFKR23BE V a.c. 5/.326/.391 7/85 5/5 1/ / CE; curus; FPFKU23BE-1 23 V a.c. 5/.335/.5 77/92 5/5 1/ / CE; Fandis 63
24 FPFK fan filter 115/23/ Va.c Current FPFKU23BE V a.c. 5/.3/.3 7/85 5/5 1/186 65,3/68, CE; curus; FPFKU23BER-1 23 V a.c. 5/.3/ /87 5/5 1/ / CE; FPFKRTBER-1 V a.c. 5/.1/.13 71/93 5/5 1/ / CE; FPFKUTBE-1 V a.c. 5/.1/.13 71/93 5/5 1/ / CE; Standard / Reverse Hz Hz FPFKRG Fandis
25 FPFKG B fan filter 115/23/ Va.c FAN FILTERS ffhigh performance Current FPFKGR115B V a.c. 5/ 1.5/ /148 6/745 2/ / CE; curus; FPFKGR115BR V a.c. 5/ 1.5/ /148 6/745 2/ / CE; curus; FPFKGU115B V a.c. 5/ 1.2/1.2 1/135 65/73 186/ / CE; FPFKGU115B V a.c. 5/ 1.5/ /148 6/745 2/ / CE; curus; FPFKGU115BR V a.c. 5/ 1.2/1.2 1/135 65/73 186/ / CE; Fandis 65
26 FPFKG B fan filter 115/23/ Va.c Current FPFKGR23B V a.c. 5/.7/ /1 6/745 2/ / CE; curus; FPFKGR23BR V a.c. 5/.7/ /1 6/745 2/ / CE; curus; FPFKGU23B V a.c. 5/.62/.81 1/185 65/73 186/ / CE; FPFKGU23B V a.c. 5/.7/ /1 6/745 2/ / CE; curus; FPFKGU23BR V a.c. 5/.4/.64 16/147 65/73 186/ / CE; FPFKGUTB-11 V a.c. 5/.1/. 93/123 65/73 186/ / CE; Standard / Reverse - 11 Standard / Reverse Hz Hz 1 FPF15KRG FPFKRG Hz Hz FPF15KRG FPFKRG 66 Fandis
27 FPFKG BE fan filter 115/23/ Va.c FAN FILTERS ffhigh performance Current FPFKGR115BE V a.c. 5/ 1.4/ /148 6/745 2/ / CE; curus; FPFKGU115BE V a.c. 5/.96/1.3 17/143 6/745 2/ / CE; FPFKGU115BE V a.c. 5/ 1.4/ /148 6/745 2/ / CE; curus; FPFKGU115BER V a.c. 5/.96/1.3 17/143 6/745 2/ / CE; FPFKGR23BE V a.c. 5/./ /1 6/745 2/ / CE; curus; Fandis 67
28 FPFKG BE fan filter 115/23/ Va.c Current FPFKGU23BE-1 23 V a.c. 5/.5/ /1 6/745 2/ / CE; FPFKGU23BE V a.c. 5/./ /1 6/745 2/ / CE; curus; FPFKGU23BER-1 23 V a.c. 5/.5/ /1 6/745 2/ / CE; FPFKGRTBER-1 V a.c. 5/.1/. 93/123 6/745 2/ / CE; Standard / Reverse Hz Hz FPFKRG Fandis
INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series
Filter fans FL-Series Heating, cooling, climate, electrical power control. Since more than sixty years. DBK s knowledge of thermal management gives us the experience to guide and support you with your
More informationNCF 60 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationNCF fans 50 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationKnürr CoolBlast. Top-Mounting Fan for Miracel
Knürr Accessories Knürr Accessories Knürr CoolBlast Top-Mounting Fan Strong points Products Fan Top 1.109 1.110 1.113 Top-Mounting Fans 1.116 Knürr CoolBlast Fan Unit Strong points Products Accessories
More informationNCF fans 60Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationstainless steel Cover hinge The cover hinge is simply screwed to the box protection channel and to the edge fold. Model No. KL
aus HB, S. 46 The Rittal range of terminal boxes offers 44 practical designs, developed and improved in constant dialogue with users. Whether with or without gland plates, in stainless steel, EMC version
More informationClimate Control Products
Products Filter Fans NEMA 1 Box Fan High airflow with low noise operations makes these versatile packaged fans very popular in a wide range of applications. Reversible mounting brackets allow user to push
More informationBefore Using a Stepping Motor
Stepping & Driver Packages 2-Phase Stepping Driver Controllers 2-Phase Full/Half Indexer out C-295 Stepping Installation Direction of Mounting can be mounted freely in any direction as shown below. Regardless
More informationWork area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page
Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:
More informationDimensions WxHxD [mm] Weight [kg]
SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly
More informationDIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits
DIN-A-MITE C TOTAL CUSTOMER SATISFACTION 3 Year Warranty SCR Power Controller Delivers Up To 80 Amperes in a Compact Package The DIN-A-MITE C silicon controlled rectifier (SCR) power controller provides
More informationCabinets Outdoor. Optimal protection from vandalism thanks to a fixing accessible only from within. Easily exchangeable exterior cladding components.
Overview..... 0 Cabinets...... 1 Outdoor Cabinets Outdoor Wall mounted cases........ 2 Accessories for cabinets and wall mounted cases 3 Climate control 4 Desk-top cases 5 Subracks/ 19" chassis... 6 41602001
More informationPEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES
power supplies Our powerful miniature units ensure optimum power supply for miniature controllers. Versions with a 12, 18 and 24 V output voltage are available, enabling them to be used in a whole range
More informationGENERAL CHARACTERISTICS
OUTDOOR CASES GENERAL CHARACTERISTICS The ATOS case in the OUTDOOR range is designed specifically to withstand the most severe environmental requirements. The case provides full protection against very
More informationPower conversion systems for energy storage. Engineering that stores
Power conversion systems for energy storage Engineering that stores INDRIVETEC Innovative Drive Technologies AG The Company Indrivetec specialises in development and manufacture of high-performance storage
More informationPART 1 GENERAL. Pfannenberg Inc.
PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES DTS COOLING UNITS FOR SIDE MOUNTING/DOOR MOUNTING TO ELECTRICAL ENCLOSURES AND INDUSTRIAL CONTROL PANELS PART 1 GENERAL 1.1 SUMMARY A. Cooling
More informationCLIMATE CONTROL SOLUTION
CLIMATE CONTROL SOLUTION Product catalog www.conteg.com Content Filter fans 3 Filter fans 4 Roof exhaust units 6 Accessories 7 Technical and assembly drawings 8 Cooling units 14 Wall-mounted cooling units
More informationFAN SYSTEM KFF VENTILATION SOLUTION FOR ELECTRICAL ENCLOSURES.
FAN SYSTEM KFF VENTILATION SOLUTION FOR ELECTRICAL ENCLOSURES IRINOX S.p.A. Via caduti nei Lager, Z.I Prealpi Loc. Scomigo 31015 Conegliano (TV) Italy T. +39 0438 2020 F. +39 0438 2023 quadri@irinox.com
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationGP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:
Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS
More informationaus SK 2000, S. 134 Mounting cutout 100.5
aus SK 2, S 134 Technical description: Quick fastening system without screws Simply lock into position and voilà! Square mounting cutout Super-slimline grille design The air direction (extracting or blowing)
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationAmperis battery regenerator
Amperis battery regenerator Universal Battery Charger/Discharger/Analyzer Amperis battery regenerator Quick regenerations Expanded lifespan of batteries The Most Energy Efficient technology available.
More informationACCESSORIES FOR SZE2 CABINETS
ZPAS 143 DOORS Doors Intended for use instead of front solid door or rear panel. Maximum door opening angle: 120 Sheet steel textured powder paint, light grey (RAL 7035), stiffened profiles, brown smoked
More informationOperating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1
7F Series - Filter Fan (24 500) m³/h (14.1...294.3) CFM 7F Features 7F.50.8.xxx.1020 7F.50.8.xxx.2055 7F.50.8.xxx.3100 Filter Fan for electrical cabinets and enclosures 120 V or 230 V AC versions Very
More informationBRIZA 22 HYBRID HEATING & COOLING
BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe
More informationAccessories. 19 Cross-Flow Fan. 19 Fan Unit 1 U. RFI Springs. This catalog contains stock and standard parts. Other products and sizes on request.
19 Cross-Flow Fan 19 Fan Unit 1 U RFI Springs 8.1 19 Cross-Flow Fan 19 Cross-Flow Fan For cooling of 160 mm deep modules. Fan for cooling of 220 mm deep modules on request. Delivery: Cross-flow fan Filter
More informationc-go 12V/10A 12V/20A Power supply and battery charger Instruction manual
c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...
More informationSITESTAR ELECTRONICS CABINET DESCRIPTION
SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3
More informationEGQ 212: Duct transducer, CO 2 and temperature
Product data sheet 7.0 EGQ : Duct transducer, CO and temperature How energy efficiency is improved Measuring the CO concentration and temperature for energy-efficient, demand-controlled regulation of the
More informationCTU 02. Thyristor switching module for fast PF compensation. User manual
CTU 02 Thyristor switching module for fast PF compensation User manual version 1.3 Czech Republic Czech Republic 1 Content 1. Function description... 3 2. Device description and indication features...
More informationVERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED
VERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED SIMPLE VERSATILITY. RELIABLE PERFORMANCE. SUBSTANTIAL SAVINGS. SolaHD IP67 SCP-X power supplies mount directly
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More informationCX-SERIES ADVANCED BATTERY CHARGER
CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...
More informationELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationAir volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)
Series - Filter Fan (24 500) m³/h (14.1...294.3) CFM 7F 7F.50.8.XXX.1020 7F.50.8.XXX.2055 7F.50.8.XXX.3100 Filter Fan for electrical cabinets and enclosures 230 V or 120V AC versions Very low acoustic
More informationHigh-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES
High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES The LHP Series offers many advantages in an industrial environment LHP SERIES Illuminates wide, open areas such as warehouses, manufacturing
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationVersatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits
Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable
More informationProduct Data For FARNELL
ae Product Data For FARNELL ae Uniset is / Varioset is ae EL ELECTRONIC KOMBI SYSTEM WALL MOUNTING Pole clamp For reliable, convenient fastening to round or square poles. For pole diameter/size:
More information85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationSmall cases... the perfect shell for valuable electronics
Small cases... the perfect shell for valuable electronics Small cases page 178 mini page 181 page 183 all standard size cards (100, 120, 160, 190 to 233,35 ) can be installed in one case favourable EMC
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationRecommended Tools: Phillips Screwdriver, Flat Blade Screwdriver, 13mm and 10mm Wrench, 5/16 nut driver,
UPS-ST-120 UPSPro Outdoor UPS System Wireless Base Stations and Client Devices Surveillance Cameras Mission Critical Backup Power Remote Sensors Congratulations! on your purchase of the UPSPro Outdoor
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationPSU EN54-4 Power Supplies
PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in
More informationJUMO MIDAS S05 Pressure transmitter Type
Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement
More informationLow Voltage AC drives. ABB Solar Pump Inverter 0.37 to 18.5KW Catalog
Low Voltage AC drives ABB Solar Pump Inverter 0.37 to 18.5KW Catalog Solar Pump Inverter Enabling the power of the Sun Low carbon economy With utilization of solar power ABB inverters helps in reducing
More informationClimateCab Cabinets and Accessories
Product Data Sheet ClimateCab Cabinets and Accessories» Free-standing ClimateCabs include a NEMA 12 Cabinet with M6 or tapped rails, plus a 5000-, 8000-, or 12,000-BTU digitally controlled air-conditioning
More informationCompact Energy Storage Module. Modular Systems, EPDS. Product overview
Compact Energy Storage Module Modular Systems, EPDS Product overview ABB Power Products in energy storage Portfolio coverage Stationary Application Focus ESM Load leveling Spinning reserve ESM Behind-the-meter
More informationSECURELY HELD. OKW ACCESSORIES are designed to be practical, thus providing you with more flexibility for your individual case.
SECURELY HELD RATIONAL HINGE AND LOCKING TECHNIQUES For easy opening of the devices. THE PRODUCT WALL / RAIL OKW offers you a comprehensive range of. Adapted to the application, our standard cases can
More informationDA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators
Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory
More informationBP- A Series Switch-Mode 3 Stage Battery Charger User s Manual
BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions..... 2 2. Features... 3 2-1
More informationLED lighting system. We Brighten Your Brands.
LED lighting system We Brighten Your Brands. Brilliance by design. PDL3 MODUS is a universal 1 for 1 upgrade of existing 400 W HID downlights, featuring application-based high (200 W), medium (150 W),
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More informationSILENT MV Ultra Quiet In-line Fans
Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent
More informationproduct specification
4414 ML Customer specification: No Version: 1.0 Created: 16.09.2011 INDEX 1 General... 2 2 Mechanics... 2 2.1 GENERAL... 2 2.2 MOTOR... 2 2.3 CONNECTIONS... 3 3 Operating Data... 4 3.1 OPERATING DATA -
More informationAsynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors
Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Series R2, Frame 63 355 Introduction KHM R2 series cast iron motors are totally enclosed fan cooled, 3 phase, and squirrel cage induction
More informationVENTILATION. Filter Fans. Example: Waste heat to be removed 500W Temperature difference 20K Air flow required 78m3/hr
Filter Fans High performance and fast mounting Modern design A positive visual impact is given by the up-to-date design of the grills and the minimal external projection. All moulded parts are made of
More informationGo Power! Manual. GP-1750HD Inverter GP-2500 Inverter
Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...
More informationORION PLUS three-phase kVA
ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through
More informationProduct Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g
Product Overview Product Wattage CCT lm Base 827 3,5 2700 210 GU5.3 Benefits For all household luminaires Low energy consumption and maintenance costs Long lifetime up to 15 years² Compact 12V-LED reflector
More informationCommand, control and regulation
186 CONTROL SYSTEMS Command, control and regulation Mechanical regulators... 188 NO-NC thermostats... 191 Twin thermostats... 192 Change-over thermostats... 193 Hygrostats... 194 Flashing signal device...
More informationCPS2000 Cabinet Power System
Input (Nominal): 90 Vac to 264 Vac (Autoranging) Output (Nominal): -48 Vdc (up to 28.8 A) and Optional 50 VA Ringing Generator The low-maintenance, outside-plant CPS2000 (Cabinet Power System) integrates
More information40W POWER LINE COMMUNICATIONS SMART LED POWER DRIVER
40W POWER LINE COMMUNICATIONS SMART LED POWER DRIVER LES-040-GP11X Digital Power Supply Overview gridcomm offers a state-of-the-art module consisting of a 40W LED power driver integrated with Power Line
More informationS /5000 BTU/Hr. 1000/1500 Watt
763.576.32 Spec-168 E763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners SPECTRACOOL Slim Fit Indoor S6 1/17 BTU/Hr. 3/5 Watt S1 34/5 BTU/Hr. 1/15 Watt S16
More information19 Server Cabinets SOHO/SMB Networking
19 Server Cabinets SOHO/SMB Networking Ideal for all 19" rackmount applications Maximum static load of 1500 kg Perforated door and ventilation slots provide excellent airflow Zinc-plated 19" mounting rails
More information3000W HF/PFC Battery Charger
3000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments > 0.98 Power
More informationContents. 1 Introduction. 2 General Product Information. 3 General Test Requirements
1 Introduction 1.1 Purpose......................................... 1 1 1.1.1 Reasons for Issue 2............................... 1 2 1.2 Scope.......................................... 1 2 1.3 Environmental
More informationProduct Data Sheet 4184 NXHH
The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating
More informationSOLSTART Instruction Manual
Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationROOF FAN ROOFMASTER STEC
AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...
More informationIP54 Floor Standing & Wall Mounted Cabinets
IP54 Floor Standing & Wall Mounted Cabinets Our IP54 Style cabinets are designed to be used in areas of high dust levels and damp environments. They are available in 12U, 27U & 42U in widths/depths of
More informationLow voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog
Low voltage AC drives ABB component drives ACS55 0.18 to 2.2 kw / 0.25 to 3 hp Catalog ABB component drives ABB component drives ABB component drives are designed to be incorporated into a wide variety
More informationALTIVAR FLEX58 Chassis Drive Controller Product Selection
ALTIVAR FLEX58 Chassis Drive Controller Product Selection Class 8806 CONTENTS Description Page General Information and Selection....................................... 2 Specifications and Ratings...........................................
More informationpartial statement 106 TITUS www.efb-elektronik.de 19 Networking cabinet TITUS S (Standard)... 108-109 19 Networking cabinet TITUS E (Enhanced)...110-111 19 Networking cabinet TITUS V (pre-assembled)...
More informationCAUTION CM-SE CM-S21 CM-S41
CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and
More informationUSER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE
USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE SECTIONS: ENGLISH 2 NEDERLANDS 17 DEUTSCH 37 Victron Energy BV De Paal 35 1351 JG Almere-Haven The Netherlands Article number
More informationPRODUCTS: POWER SUPPLY
PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER
More informationDifferential Pressure Sensors
1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output
More informationMicroswitches MK series
D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page
More informationGRANITE ENCLOSURES MODEL NO. NPS Standard Features
MODEL NO. NPS-6-- --0666 Standard Features CSA and NEMA 3R (UL50) 1800 Amps @ 24Volt / 900 Amp @ 48Volt back up power Solid steel frame and shelf construction with 2 high sub-frame platform. Available
More informationVA-7450 Series. Electric Valve Actuators
34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional
More informationTHE CALCULATION THAT MAKES SENSE!
Otto Pfannenberg s invention of the Filterfan in 1958 was a milestone in the area of industrial thermal management. Today Pfannenberg provides a wide range of different solutions for industrial thermal
More informationFM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES
G2 SERIES G2 Industrial METER MODULES FM Approved Remote Kit Assembly (Part No. 113275-1) Maintains FM Approval. Accommodates fluid temperatures from -40 F to +250 F (-40 C to +121 C) depending on meter.
More informationEQUIPMENT PROTECTION
Contractor Specifier s Guide EQUIPMENT PROTECTION WWW.PENTAIRPROTECT.COM/HOFFMAN Volume 8 Hoffman Has You Covered From utility junctions to protecting relays, contactors and wire, Hoffman has you covered.
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41
More informationABB component drives ACS150, 0.5 to 5 Hp
ABB component drives ACS150, 0.5 to 5 Hp Technical Catalog BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES Contents Choice 1: Simply contact your local ABB drives sales office
More informationDIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14
Bild fehlt noch DIAPHRAGM PUMPS SLL series 8 EL-N series 9 EL-S series single system 1 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 5 Applications Water treatment and environmental
More informationGTS-L4 5 / 10 / 15 TECHNICAL DATA
GTS-L4 5 / 0 / 5 POWER SOLID STATE RELAYS WITH FOUR INDEPENDENT SOLID STATE RELAYS Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationProduct Data Sheet 4184 NGX
The engineer's choice 4184 NGX INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating
More informationSUPER DUTY THE AFFORDABLE SOLUTION 8685 Station Street, P.O. Box 90, Mentor, OH 44061-0090 USA P: +1-440-255-9333 F: +1-440-255-6427 E: solutions@lintern.com www.lintern.com SUPER DUTY CONDENSER TOTAL
More informationKSOM Control exhaust valve
KSOM Control exhaust valve KSOM is ideal for rooms which require forced exhaust air flow. KSOM consists of exhaust valve, control motor and controller card, which are installed in the valve cone. KSOM
More informationPremounted Midi Shunts
Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts
More information