1 Components Power Supplies and Converter DC/AC Converter Generic Product Catalog
2
3 Power Supplies and Converter - DC/AC Converter Table of Contents Introduction DC/AC Converter... 1 DC/AC Converter Typologies 5 kva DC/AC Converter kva DC/AC Converter... 7 Appendix Notes Traceability of Reviews Table of Reviews This publication is AECMA S1000D compliant. I
4 Generic Product Catalog II All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
5 Power Supplies and Converter - DC/AC Converter DC/AC Converter Construction features "Power supply systems with static converters" are suitable for outdoor use in places located near the track. The rack and all the internal metallic accessories, including screws and nuts, are AISI304 stainless steel. Racks with max 6kVA power shall be installed on pole. Racks with power between 6kVA and max 200kVA shall be installed at ground level on a cement bedplate with connection cable inlet from the bottom and/or from the top. Power cord features 50kV isolation at 50 Hz and 125 kv pulse and is fitted with a metallic screen of at least 70nmq. Every device is fitted with proper anti-vibration systems. The protection class with doors closed is IP54. The protection class with open doors, for both the MT (medium voltage) and bt (low voltage) compartments, is IPXXB at least. MT/bt compartments can only be accessed after removing the appropriate panels using the tools provided for the purpose. Suitable warning signs shall be affixed on every removable part that provides access to live components and/or energizable components. Functions Whatever internal malfunctioning affecting the converter, including sectioning device, fuse and arrester, won't have effect on the continuity of the 3.6 kvdc power supply line. Connecting cable screen discharge (if any) to the dc line will trigger the fuse. Fuse operation is monitored via the status change of an electric clean contact (fuse tripping) connected to the terminal block. Automatic operating time is lower than 15 seconds from when voltage will be present on the dc line, voltage can be regulated between 2200 and 3300 Vdc. Energy quantities Supplied energy quantities feature one minute sampling rate and are stored in a memory which can be consulted for a thirty-years period. Functions towards the outside It has been provided the transmission via fiber optic terminal, supported by standard FS protocol, of controls and diagnostic data concerning: - local/remote service selection - control and monitoring converter on/off - on/off indication - power-on number counter - Counter of the number of automatic shutdowns due to input overvoltage and undervoltage - Permanent monitoring of the connection integrity of the negative reference wire and issue of the relevant alarm for negative connection break. - Alarm for current passing through power cord screen connected to the TE protection circuit. - MT fuse tripping indication. - Disconnector on/off state. - Input voltage measure. - Internal temperature on at least two different stages of the pole-installed device and four on ground-installed devices.. Ancillary equipment Systems come with the following accessories: Pole-type version: - Lower support complete with bolts for universal fastening on poles of the "M" type and "LS" type (collars excluded). - Upper support complete with bolts for universal fastening on poles of the "M" type and "LS" type (collars excluded). - Single-pole disconnector with MT fuse and fuse holder, complete with hand winch with transmission operation from the bottom (operating rod excluded). Introduction Converter activation after manual or automatic disconnector making is subject to a local/remote switch: in local it will be of the manual type whereas in remote it will be of the automatic type. Selectable (local/remote) activation control/procedure has been provided. Exceeding the frequency range and/or the output voltage will result in converter shutdown. In case of power absorption > 100% than rated power, the converter will limit current to the max admitted value. In case of output short circuit, a protection circuit for electronic components will limit the current to 150% peak of the nominal current; should this condition last, an output automatic breaker will cut-in. Connection continuity to CDTE and to CPTE is monitored. Ground-type version: - Single-pole disconnector with MT fuse and fuse holder, complete with hand winch with transmission operation from the bottom (operating rod excluded). - MT cable, 10 meters. CDTE and CPTE connection continuity checks Connection or CDTE or CPTE lack of continuity will result in converter locking within max 100 ms. Converter is reconnected following the sequence below: 1. Open the disconnector on MT side 2. Reset CDPE or CPTE connection or connections 3. Close the disconnector on MT side. Rack structure Rack structure is in press-bent sheet plate with first-class, 15/10 nm thickness, AISI 304 rolled steel sections, painted externally with RAL 7044 color. Optional accessories MT disconnector remote control motorization. This publication is AECMA S1000D compliant. 1
6 Generic Product Catalog Electrical characteristics: Vdc external power supply - Remote local selector - Electrical/mechanical lock of the two positions. - Extraction key on open position from local. - Local opening/closing both electrical and manual. Introduction Mechanical characteristics: - Point machine preset for both piling installation and installation on "M" and "LS" poles - Steel structure, 15/10 thickness - External painting RAL Door with key-lock, FS standardized type. 2 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
7 5 kva DC/AC Converter Power Supplies and Converter - DC/AC Converter The 5 kva version, to be pole-installed and to be used for powering signaling huts, TxD system shelters located along the line, line lighting systems for TE system maintenance, tunnel lighting systems, points heating BTS systems for small-layout stations, etc. DC/AC Converter Typologies This publication is AECMA S1000D compliant. 3
8 Generic Product Catalog DC/AC Converter Typologies General Features Part number: Format: Size [l, h, d] [mm]: Front Panel: MTBF [h]: 700, 1.400, 550 > load max. Weight [g]: Front panel color: RAL7044 Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude[m]: Relative humidity: < % (@ 30 C) non-condensing Composition: Obsolescence: HW revision: SW revision: SW file: Naming: Certifications and conformity: CEI EN ; CEI 64-8; CEI EN ; CEI EN 50119; CEI 20-13; CEI 20-38; IS 365/ ed.2008; IS 402 A ed.2000; IS 728 ed no Technical Features Power supply Power supply system nominal voltage [kvdc]: 3,6 Max permanent voltage [kvdc]: 3,6 Max non-permanent voltage Umax2 (t < 5') [kvdc]: 3,9 Max transient no-load voltage Umax3 (t = 20 ms) [kvdc]: 5,2 Output Single-phase/three-phase output voltage [Vac]: 230 ± 1% Frequency [Hz]: 50 ± 1%; Ripple: 125% max. per 5' Rack characteristics Paint flatness degree: < 25 gloss Paint thickness [μm]: 70 typ. (40 min.) Paint type: Polyester powder Protections In the event of power absorption > 100% than nominal power, converter will limit current to the max admitted value. In the event of output short-circuit, there is a circuit fitted which protects the electronic components by limiting current to 150% nominal current peak; output automatic switch is also fitted. Ground isolation voltage monitoring with safety circuit intervention to prevent dangerous accidental contacts. Remote diagnostics via fiber optic link; transmission via fiber optic terminal supported by FSIEC870.5 standard protocol of diagnostic controls and data concerning: 1. On/Off 2. Running hours 3. Power-on number 4. Number of shutdowns due to input overvoltage/undervoltage 5. Ground failure alarm 6. Input voltage measurement 7. Output Power measurement 8. Inner temperature into the two stages 9. Permanent control of the integrity of the connection of the negative reference conductor 10. Local/remote operating choice 11. On/off warning 12. Fuse release 13. On/off sectioning switch state MTTR: < 30' Technical features subject to variation without notice. Schematic 4 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
9 Power Supplies and Converter - DC/AC Converter DC/AC Converter Typologies 1. Air extraction 2. Control board first stage 3. First stage magnetic 4. Capacitor HV 5. Second stage control boards 6. Filter capacitors 7. Inductor filter 8. Isolation trasformers 9. Antivibration support 10. Protection grid 11. Natural air sinks converter This publication is AECMA S1000D compliant. 5
10 DC/AC Converter Typologies Generic Product Catalog Example of installation on long pole line, ver. 5kVA 6 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
11 40 kva DC/AC Converter Power Supplies and Converter - DC/AC Converter The 40 kva version, to be ground-installation along the line and to be used for powering signaling huts, TxD system shelters located along the line, line lighting systems for TE system maintenance, tunnel lighting systems, points heating BTS systems for small-layout stations, etc. DC/AC Converter Typologies This publication is AECMA S1000D compliant. 7
12 Generic Product Catalog DC/AC Converter Typologies General Features Part number: Format: Size [l, h, d] [mm]: Front Panel: MTBF [h]: 810, 880, > load max. Weight [g]: Front panel color: RAL7044 Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude[m]: Relative humidity: < % (@ 30 C) non-condensing Composition: Obsolescence: HW revision: SW revision: SW file: Naming: Certifications and conformity: CEI EN ; CEI 64-8; CEI EN ; CEI EN 50119; CEI 20-13; CEI 20-38; IS 365/ ed.2008; IS 402 A ed.2000; IS 728 ed no Technical Features Power supply Power supply system nominal voltage [kvdc]: 3,6 Max permanent voltage [kvdc]: 3,6 Max non-permanent voltage Umax2 (t < 5') [kvdc]: 3,9 Max transient no-load voltage Umax3 (t = 20 ms) [kvdc]: 5,2 Output Single-phase/three-phase output voltage [Vac]: 400 ± 1% Frequency [Hz]: 50 ± 1%; Ripple: 125% max. per 5' Rack characteristics Paint flatness degree: < 25 gloss Paint thickness [μm]: 70 typ. (40 min.) Paint type: Polyester powder Protections In the event of power absorption > 100% than nominal power, converter will limit current to the max admitted value. In the event of output short-circuit, there is a circuit fitted which protects the electronic components by limiting current to 150% nominal current peak; output automatic switch is also fitted. Ground isolation voltage monitoring with safety circuit intervention to prevent dangerous accidental contacts. Remote diagnostics via fiber optic link; transmission via fiber optic terminal supported by FSIEC870.5 standard protocol of diagnostic controls and data concerning: 1. On/Off 2. Running hours 3. Power-on number 4. Number of shutdowns due to input overvoltage/undervoltage 5. Ground failure alarm 6. Input voltage measurement 7. Output Power measurement 8. Inner temperature of the two stages 9. Permanent control of the integrity of the connection of the negative reference conductor 10. Local/remote operating option 11. On/off warning 12. Fuse release 13. On/off sectioning switch state MTTR: < 30' Technical features subject to variation without notice. Schematic 8 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
13 Power Supplies and Converter - DC/AC Converter DC/AC Converter Typologies 1. Solar irradiation protection 2. Cabinet ventilation 3. Protection grid 4. Capacitor HV 5. Control board 1 stage 6. Power converter heat sink 7. Control board 2 stage 8. Filter capacitors 9. Inductor filter 10. Isolation transformer 11. Antivibration support This publication is AECMA S1000D compliant. 9
14 DC/AC Converter Typologies Generic Product Catalog Example of ground-installation along the line, ver. 40 kva 10 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
15 Power Supplies and Converter - DC/AC Converter Notes Appendix This publication is AECMA S1000D compliant. 11
16 Appendix Generic Product Catalog 12 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
17 Power Supplies and Converter - DC/AC Converter Table of Reviews REV. DATE Prepared Approved Authorised Revision Reason /07/2010 Bottino D. Vernazza M. Casazza A. Traceability of Reviews This publication is AECMA S1000D compliant. 13
18 Generic Product Catalog 14 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.
19 Property of Ansaldo STS SpA, all rights reserved. The copying, reproduction and use of this work in any form whatsoever is forbidden without the written authorization of Ansaldo STS SpA.
20 Ansaldo STS SpA Via Paolo Mantovani Genoa Italy
DC POWER SUPPLY SYSTEMS
DC POWER SUPPLY SYSTEMS double branch Rectifier - SCR type TITANIUM 2R-SCR PLUS SERIES TITANIUM 2R-SCR rectifier series belongs to the Double Branch category thus provided with two independent AC / DC
More informationdesigning and producing a wide range of railway power converters and devices since 1986 FOCUS ON TRANSPORT ELECTRONICA
designing and producing a wide range of railway power converters and devices since 1986 FOCUS ON TRANSPORT ELECTRONICA TROLLEYBUS CATENARY SUPPLIED BATTERY CHARGER The trolleybus catenary supplied battery
More informationAME. Rectifier - Battery charger. Industrial applications: Key features:
Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);
More informationWorld Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants
World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable
More informationManual for Inverter system type PCI05
- 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause
More informationTechnical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER
Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...
More informationType SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.
Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings
More informationMedium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications
Medium voltage products UniSec Y800 New 24 kv air-insulated medium voltage switchgear to e-istribuzione specifications UniSec Y800 ubicles available Unit e-istribuzione specifications (Ed. 4) UniSec IS/1
More informationProducts Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0
Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More information10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph
VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery
More informationPRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0
PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationnonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS
RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan,
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More information.3 Section Waste Management and Disposal.
Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section
More informationIndustrial Chargers and
Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationSECTION DC POWER SUPPLY/BATTERY CHARGER
SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance
More informationTechnical Specification SENTINEL PRO
Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES
More informationPhoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationORION PLUS three-phase kVA
ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through
More informationSolar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationPRODUCT CATALOGUE 2016
PRODUCT CATALOGUE 2016 Static digital voltage stabilisers The static stabiliser is used when the correction speed represents the critical issue (for example, computers, laboratory equipment, measuring
More informationSwitching Power Supplies
, 18 150 Watt Features Compact boxed power supplies with screw terminal block Universal input 85-264 VAC, 50/60 Hz Short circuit and overvoltage protection High efficiency International safety approvals
More informationINSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00
INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationMaintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C
C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER
More informationDead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability
Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationQUEENSLAND URBAN UTILITIES
DOCUMENT NO : EQUIPMENT NO : PREPRED : CHECKED : PPROVED : SHEET NO : 1 of 6 GENERL 1 Battery Charger DCC Inverters 3 DCDC Converters 4 System Design Life (other than batteries) Years 5 Battery Design
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationABB central inverters PVS to 2091 kva
SOLAR INVERTERS ABB central inverters PVS980 1818 to 2091 kva 01 ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators
More informationTitle High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title High Voltage and 1500 System Earthing References and Definitions Reference Number PDS 02 (RIC Standard: EP 12 00 00 01 SP) Document Control
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationRELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES
RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION
More informationDC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual
DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This
More informationCatalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector
Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds
More informationDUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL
72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications
More informationBellMega BM-510. Operation Manual Ver: 1.0 Rev: 1
BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for
More information1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems
Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.
More informationINDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV
MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,
More informationPower Supplies. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high effi ciency and compact size with new visual diagnostic LEDs
More informationCentral Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT
Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT Maintenance Manual SCCP-WH-B4-en-20 98-4046720 Version 2.0 EN SMA Solar Technology
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationIndustrial Power Supplies
, Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with
More informationPOWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.
POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I
More informationS&S POWER SWITCHGEAR EQUIPMENT LTD.,
S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,
More informationQUOTATION BLADE 7 LX. Product code GEAL6S2BAA
1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...
More informationModels. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery
AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit
More informationPURE SINE WAVE DC TO AC POWER INVERTER
PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series
More informationFeatures. Description. Table of Contents
Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationPower Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS
Power Quality Solutions 2018 POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS ACTIVE Ematic FA40 New Series ICAR: products and solutions Founded in 1946, ICAR is a leading manufacturer of capacitors and
More informationINTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist
INTER PLANT STANDARD - STEEL INDUSTRY IPSS THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS Corresponding IS does not exist IPSS: 1-10-038-08 0 FOREWORD 0.1 This Inter Plant Standard has
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationINTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)
INTER PLANT STANDARD STEEL INDUSTRY I P S S SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) Corresponding IS does not exist IPSS: 1-10-036-12 0 FOREWORD 0.1 This
More informationPOWERTRONIX QUASAR 5-40 KVA
POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251
More informationCentral Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20
Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Maintenance Manual SC500-800HE20-WH-en-10 98-4110410 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationMINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial
More informationPower Lynx 3 Uninterruptible Power System (UPS) Technical Specifications
Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible
More informationMEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV
CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationDART Charger Product Description, Information and Specification
g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY
More informationSPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W
Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration
More informationGTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA
GTS-L / 0 / POWER SOLID STATE RELAYS WITH LOGIC CONTROL Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging machines Temperature
More information1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General
SPW TPW6B series SCR Electronic Voltage Stabilizer/Power Conditioner for Industries Use Applications: Printing Specific /Medical Specific /Control Numerical Machine/Elevator Specific /Testing Specific/UPS
More information150 WATT HEW SINGLE SERIES DC/DC CONVERTERS
Features Description The 4:1 Input Voltage 150 W single HEW Series of DC/DC converters provide precisely regulated dc outputs. The output voltage is fully isolated from the input, allowing the output to
More informationOffshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure
POWER SUPPLY SYSTEMS FOR HIGHER PROTECTION CLASS Our power supply systems offer a protection class up to IP 55. Together with our Industrial building blocks it is suitable for a variety of applications,
More informationMEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices
MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH
More information8DJ. Maintenance-free for lifetime
8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and
More informationAMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism
AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC Universal applications: Medium voltage motor starting applications Capacitor switching Retrofit applications to replace
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationOutdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv
Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker
More informationINSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03
INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment
More informationEmergency lighting units EM powerled
BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual
More informationInstallation and Operations Manual
Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com
More informationFortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting
More informationZX-Family Gas-insulated medium voltage switchgear
ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom
More informationOutdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications
Outdoor live tank SF 6 circuit breaker Type OHB for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers
More informationSolar Inverter Manual
Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage
More informationTitle Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationVSD Series II Variable Speed Micro Drives
VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationAg Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption
Datasheet Ag103 Intelligent Sealed Lead Acid Solar Battery Charger Module Pb 1 Features Multi-Stage Charging Solar Panel or DC Input Maximum Power Point Tracking (MPPT) Very Low Power Consumption Wide
More informationRedundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies
Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC
More informationLiebert Hipulse E The High-ECO-Availability UPS. AC Power Systems
Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions
More information1.5KW DC-DC Converter Specification
1.5KW DC-DC Converter Specification TDC-J Series V 3.2 Date 2016-10-14 1 Table of Contents 1 Overview 2 Basic functions 3 Technical Specifications 3.1 Product Naming 3.2 Model List 3.3 Model selection
More informationOutdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers
More informationProduct brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring
Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring ABB is a leader in power and automation technologies that enable utility and industry customers to
More informationDocument: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
More information