1 ADDENDUM TO THE STC PRO LOGGER II MANUAL 1. Probe Test for Testing Double Insulated Appliances (Utilities Menu) The SafeTcheck Pro Logger II now has a new feature Probe Test, available on all testers with Firmware Version V4.46 and above. By default Pro Loggers use the unique feature CheckConnect in conjunction with a Stainless Steel Cloak to perform an Insulation Resistance (IR) test on Double Insulated Appliances. CheckConnect ensures the Device Under Test (DUT) is both correctly connected to the Pro Logger (to provide a return path for leakage currents) and its exposed surfaces adequately covered to reduce the chance of an erroneous test result. During a Probe Test the CheckConnect feature is disabled. This gives the operator the ability to use the probe, the cloak or a combination of both to test Double Insulated Appliances. The test also provides adequate time to move the probe to several points on the DUT s surface before the test is complete. WARNING: Unlike CheckConnect the Probe Test does not look for a completed return circuit. A test conducted without a return circuit is an invalid test; unfortunately the Pro Logger II will still indicate a PASS test result. In some cases the operator may find that the Probe Test is more appropriate or convenient e.g. the size or physical location of the DUT may make it difficult to use the cloak or CheckConnect. To switch between the Double Insulated Probe Test and CheckConnect Options, go to the Utilities Menu under the F2 Key, Scroll down to the CheckConnect Option using the F2 Key and then select the required option. The selected option will always have a small rectangle to its right. NOTES: 1. TRIO Smartcal recommends the use of CheckConnect for most, if not all, IR tests on Double Insulated appliances. Failure to use this option with an incorrectly connected appliance may mean the test result is incorrect. This potentially dangerous situation exists with any Portable Appliance Tester without CheckConnect (please refer to the Warning above). 2. Correct use of the Cloak and CheckConnect is recommended to protect the operator from electric shock. This feature complies with the mandatory Safety Standard AS SAFETY OF MACHINERY DESIGN AND OPERATION. Notice Issued: 28 th September 2012 Page 1 of 6
2 2. Three (3) Pin Class 2 Run Test (Other Appliance Menu) Appliances connected to the mains via a 3 pin plug with no Double Insulated (Class 2) symbol visible, should be considered Earthed Appliances (Class 1), however, with some appliances of this kind, the earth conductor provides not only a degree of electrical safety but also a path to conduct EMI currents, to reduce noise. This EMI current may cause an appliance to fail due to, what the Pro Logger sees, as excessive leakage. Also, with some other appliances, there is simply no practical way of finding a connection to the Earth Conductor i.e. it has no exposed earthed metal parts. To test these appliances, a Three (3) Pin Class 2 Run Test has been provided (via the Other Appliance Menu) with the Pro Logger. The first phase of this test, while running the appliance, looks for 1mA of leakage current between the Pro Logger s Cloak and the appliance s case i.e. a standard Double Insulated Run Test. If the Pro Logger measures more than this, it will try again with an increased 5mA threshold (because the appliance is Earthed, up to 5mA of Leakage Current is permissible). The person conducting the test will be warned that the 1mA threshold has been exceeded and that a 5mA test will be conducted. Any more than 5mA of leakage current will cause the test to fail. NOTE: This test does not look for the presence of an Earth Conductor. It should only be used if the normal Earthed Appliance Insulation Resistance Test continually has failed. 3. Additional function to discard failed Electrical Tests (Database function) A new feature has been added to the Data Logging function that gives a user the option to discard a failed Electrical Test is available on all testers with Firmware Version V4.56 and above. With the Data Logging Enabled, if an Electrical Test fails, then the user will be prompted to either: save the test information by selecting Start, or abandon the information by selecting Reset. This feature greatly reduces the number of records stored in the Pro Logger s memory. It also reduces the time for editing the resultant data file, if bad test data has been logged to memory i.e. a failed test that is not an Electrical Fail but the result of incorrect connection or setup. Notice Issued: 28 th September 2012 Page 2 of 6
3 4. Additional Two (2) Wire Lead Test (Lead Test function) Many modern appliances use a two wire mains power lead with a figure 8 style socket i.e. no earth conductor. The Pro Logger s Lead Test will now test this style lead as a Class 2 appliance (requires an adaptor STCIEC2F8). The Pro Logger will conduct an Insulation Resistance (IR) Test if the lead is found to have no earth by design (requires confirmation by the user). The IR is measured between the inner mains conductors and the Pro Logger s Cloak which is wrapped around the length of the lead. This feature is available on all testers with Firmware Version V4.64 and above 5. User option to bypass a Failed Continuity (Double Insulated & Earthed Appliance Test functions) (Utilities Menu - V5.20 only) While performing Insulation Resistance (IR) tests on Double Insulated or Earthed Appliances, it may be difficult, or even impossible, to complete the test because of a reported Continuity Failure. This may be a result of the appliance s Mains or On/Off Switch not being closed; or the Pro Logger interpreting a closed switch with high impedance, as not closed. If the Pro Logger reports a Continuity Failure, the Pro Logger presents the user with an option to bypass the error and proceed to the IR test. A user should only proceed if the following is true: 1. the user is satisfied that the appliance s mains switch is closed; and 2. the mains switch doesn t require mains power to be activated. This may be occur when testing Phone Battery chargers such as those for iphones. Applies to Firmware Version V4.67 to V5.09 & Hardware V7.0 For Firmware V5.20 and above & Hardware V8.0 this function may be turned on or off by selecting Fail on poor cont via the Utilities Menu (F2 Key). NOTE: If in doubt, do not bypass the Continuity Failure error. Always err on the side of caution and consider the test a failure. Notice Issued: 28 th September 2012 Page 3 of 6
4 6. RCD Trip Time Threshold (Portable 30mA RCD Test function) When testing Portable RCDs the trip current is suddenly applied and the trip time measured. In the case of 30mA Portable RCDs the acceptable trip time is 300mS however at 150mS (a threshold considered good practice AS37060:2010) the Pro Logger will fail the RCD in Firmware below Firmware Version V4.46; for V4.46 and above the Pro Logger will provide the user with a warning (not a fail) if the Trip Time is 150mS but 300mS. 7. Results Dump (Database function) A results dump function has been added to all Pro Logger IIs to enable test data to be streamed directly into 3 rd party software packages. While using the Pro Logger II in conjunction with FASTtag Asset Management Software, test data may be streamed directly to FASTtag s database; either in real time or after the completion of tests. The onboard database must be disabled (via the Utilities Menu) if results are streamed to the FASTtag Software in real time. Notice Issued: 28 th September 2012 Page 4 of 6
5 8. Three (3) Phase Run Test Option (Other Appliance Menu) Optional run (current leakage) testing of Portable 3 Phase Appliances in accordance with AS/NZS This option is available with 20 and/or 32A 3 phase sockets or other current ratings as requested. The test (via the Other Appliance Menu) looks for an Earth Connection <= 1 Ohm; a run current to ensure the appliance is switched on and running; and a leakage current of <= 5mA. The test is a Long Run Test. It may be shortened at any time after the test commences by pressing Reset twice in quick succession. If any of the test parameters (Earth Current, Run Current or Leakage Current) fail, then the 3 phase test fails otherwise the Pro Logger will indicate a pass. This test requires 2 connections to the Pro Logger: an earth return connection to the Device Under Test s (DUT) chassis; and a connection the 20 or 32A 3 phase socket adaptor (this is a din type socket in the well of the Pro Logger II). The 3 phase socket adaptor is plugged into a 3 phase power source, then the DUT into the 3 phase adaptor. The DUT should be running to conduct a test. To test a 3 phase extension lead, run a test with the extension lead connected between an already tested (and passed) 3 phase appliance and the 3 phase adaptor. Notice Issued: 28 th September 2012 Page 5 of 6
6 9. Battery Power Option (where fitted) Users of the Battery Power Option should note: 1. Insulation and earth testing only are available in Battery mode 2. To enter Battery mode press Start until the Pro Logger beeps (battery symbol in the bottom left corner of display will appear in this mode) 3. In Battery mode the Pro Logger will automatically shut down after 3 minutes, if no key is pressed 4. The Pro Logger may be switched from battery to mains without losing power (the battery will not charge in this mode - see Battery Charge Mode) 5. Failing to follow these instructions will reduce battery life and void the battery s warranty For a new Pro Logger ensure the battery is initially fully charged: 1. Power the Pro Logger from mains power 2. Set the Pro Logger into Charge mode (see below) 3. Wait for Charge Complete prompt to appear and then press Start 4. Turn the Pro Logger off by disconnecting the mains power Battery Charge Mode (following these steps will extend the life of the battery): 1. Power the Pro Logger from mains power (If already on, switch off and back on again) 2. The prompt select test needs to be displayed (If in database mode, press reset unil select test is displayed). The Battery will now be charging 3. Wait for the Charge complete prompt to appear 4. Press Start to acknowledge the charged condition 5. When fully charged the Pro Logger may be stored or it is ready for appliance testing NOTE: 1. While charging, do not select any tests, this will disable the battery charge mode (if this occurs, remove the mains power and restart the Battery Charge Mode sequence). 2. The battery will not charge while the Pro Logger is in Test mode 3. A low battery condition will display a screen message Low battery reconnect to mains 4. Storing the Pro Logger with a flat or partially charged battery will decrease the life of the battery 5. Recharge at least every 6 months, more often if possible TRIO Smartcal Pty Ltd ABN James Street Thebarton SA 5031 Procedures may change without notice. Always check the website for upgrade information. For more information regarding these features or for any questions relating to the STC Pro Logger II, please check the website or call (Weekdays 8:30am 5:00pm CST) Sales: Service: Fax: sales@triosmartcal.com.au Notice Issued: 28 th September 2012 Page 6 of 6
1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.
1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. KYORITSU will not accept liability for any damage or injury caused by misuse
More informationEZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL
EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL CONTENTS 1. Safe testing... 2 2. Product summary and explanation... 5 2.1 Product summary... 5 2.2 Test Function... 5 2.3 Features...
More informationNewcastle Weighing Services Pty Ltd
Newcastle Weighing Services Pty Ltd Revision Sheet Revision 1 Marcus Graham Split Weighing in ClearWeigh This document describes the use of the split weighing facility in the ClearWeigh Touch Terminal
More informationClamp Earth Tester MET-2. Instruction Manual
Clamp Earth Tester MET-2 Instruction Manual Thank you very much for selecting our clamp earth tester. This model is complex instrument and employs a very reliable mechanical/electronic design. Before you
More informationOrica Seismic Electronic Initiation System OSEIS TESTER. Manual
Orica Seismic Electronic Initiation System OSEIS TESTER Manual Version 2.00a, November 2006 Overview Oseis System... 2 1. Oseis Detonator, Tester and accessories... 3 1.1 Oseis electronic detonator...
More informationMULTI FUNCTION POWER PAK PLUS
MULTI FUNCTION JUMP START UP TO V8 PETROL & DIESEL 600A PEAK CURRENT RECHARGE USB POWER TOOLS TABLETS LAPTOPS MOBILE PHONES RECHARGE DEVICES ON-SITE VEHICLE JUMP STARTER KP1404 ED2 (June 15) Table of Contents
More informationUser Manual Back-UPS BX650CI-MS 230 Vac with AVR
User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety
More informationSafetyPAT Plus A B P/N:
SafetyPAT Plus A B C P/N:110401103864 Test Instrument Solutions SafetyPat Plus Instructions A.Features SafetyPat Plus The SafetyPat Plus is a handheld battery powered unit suitable for carrying out electrical
More informationUser Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V
User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, oate, service or maintain
More informationBack-UPS 650 VA 230 V with AVR (BX650CI-ZA)
Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
More informationFREQUENCY INVERTER INSTALLATION & USER GUIDE
En FREQUENCY INVERTER INSTALLATION & USER GUIDE Thank you for purchasing our frequency inverter. Please read the manual carefully before installing or using it and keep it for future reference after installation.
More informationService Manual BLACK DIAMOND SERVICE MANUAL. V.160 November
BLACK DIAMOND SERVICE MANUAL V.160 November 2011 www.montrealchargeur.com www.battelec.ca www.doctorfleet.com Page 1/30 1. SAFETY PRECAUTIONS 1 Before to start using the Black Diamond Charger, read these
More informationBegin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A
HIMOTO ZTW Brushless Electronic Speed Control for car or truck Thank you for purchasing ZTW Brushless Electronic Speed Controller(ESC). The ZTW electronic speed control (ESC) is specifically designed for
More informationWallbox Commander. User Guide WBCM-UG-002-EN 1/11
Wallbox Commander User Guide 1/11 Welcome to Wallbox Congratulations on your purchase of the revolutionary electric vehicle charging system designed with cuttingedge technology to satisfy your daily needs.
More informationZoneTouch V2 Zone Control System Installation Manual
ZoneTouch V2 Zone Control System Installation Manual www.polyaire.com.au 2014 Polyaire Pty Ltd TABLE OF CONTENTS 1) Application 2 2) Features 2 3) Components 3 4) Configuration 4 5) Pre-Installation 6
More informationSolar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5
More informationINSTRUCTION MANUAL PORTABLE APPLIANCE TESTER
INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER KEW6201A CONTENTS 1. Safe testing 1 2. Procedure of removing cover. 3 2.1 Method of removing the cover. 3 2.2 Method of storing the cover. 3 3. Product summary
More informationECONOMISER SERIES E2T USER MANUAL
TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014
More informationChargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine
Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications
More informationTRIPS AND FAULT FINDING
WWW.SDS.LTD.UK 0117 9381800 Trips and Fault Finding Chapter 6 6-1 TRIPS AND FAULT FINDING Trips What Happens when a Trip Occurs When a trip occurs, the drive s power stage is immediately disabled causing
More informationB-RAD Select USER MANUAL TABLE OF CONTENTS
TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...
More informationKEWTECH. KT56 digital multi function tester. Instruction manual
KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating
More informationPower Inverter. User s Manual. Diamond Series CPD1200EILCD
Power Inverter Diamond Series CPD1200EILCD User s Manual 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements
More informationPro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationDoes Your Electrical Safety Testing Routine Need a Boost? Exploring the Benefits of the Line Leakage and Functional Run Tests
Does Your Electrical Safety Testing Routine Need a Boost? Exploring the Benefits of the Line Leakage and Functional Run Tests Introduction Most electrical product manufacturers perform safety tests on
More informationCompetition Electronics, Inc
Competition Electronics, Inc Turbo35-GFX LiPo User s Manual Addendum 1 Introduction This enhancement makes it possible to charge 1,2 and 3 cell LiPo battery packs with the T35-GFX. Now you can have the
More informationIssue 2.0 December EPAS Midi User Manual EPAS35
Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started
More informationPAT120, PAT150 and PAT150R
PAT120, PAT150 and PAT150R Simple tick or cross, pass or fail indication plus measurement Battery powered with rechargeable options Safe 250 V insulation and leakage test for surge-protected and IT equipment
More informationSection 55 Chapter 6
Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main
More informationBIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL
E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature
More informationMODEL No s: PP3, PP3K
instructions for: Power PROBE 3 12-24v MODEL No s: PP3, PP3K Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
More informationMotor Protection With The MonitorPro
Motor Protection With The MonitorPro This application note can show you the easy way to protect your motors and your pump stations. The MultiTrode MonitorPro can protect your motors from a wide range of
More information1.Safe testing IMPORTANT:
Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.
More information5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810
5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please
More informationC.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values
C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information
More informationI. Safety precautions
. Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around
More informationBellMega BM-510. Operation Manual Ver: 1.0 Rev: 1
BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for
More informationAtlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.
GB60/70-9 Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter Model ESR60/ESR70 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2004/2016 In
More informationSimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0
SimplePAT Battery Powered Portable Appliance Tester User Manual Issue 1.0 CONTENTS SAFETY 4 GETTING STARTED 5 INTRODUCTION 6 FEATURES 7 PLANNING THE TESTS Determining the Class of construction 9 Type
More informationLevel-Up Motorhome Leveling
Level-Up Motorhome Leveling Rev: 08.06.18 Page 1 CCD-0001751 TABLE OF CONTENTS Introduction 3 Components 3 Operation 5 Selecting a Site 5 Automatic Leveling Procedure 5 Automatic Leveling Descriptive Logic
More informationTracer VM with User Interface
Tracer with User Interface Flowmeter with FCI (Fluid Characteristic Indication) Operating Instructions General The Tracer Flowmeter provides: 0 to 5V or 0 to 10V Selectable Analog Flow Output 0 to 5V or
More informationEPAS Desktop Pro Software User Manual
Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1
More informationUP100AC INSTRUCTION MANUAL
UP100AC AC/DC Charger INSTRUCTION MANUAL 100W 10A TABLE OF CONTENTS Introduction... 2 Special Features... 4 Warning and Safety Notes... 6 Lithium Battery Connection Diagram... 10 Operation Diagram - Homepage...
More informationCP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable
CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable Chilicon Power Aug 2016 1 CONTENTS CP-250E Microinverter System... 3 The CP-100 Cortex Gateway... 3 Important Safety Information... 4 Inverter
More informationMoistureMatch A next generation grain tester
MoistureMatch A next generation grain tester A next generation moisture tester incorporating new and unique technology. Finally, a portable tester that will more accurately match and track with the commercial
More informationOmniScan MX2. Getting Started Guide. Intended Use. Instruction Manual. Safety Signal Words
OmniScan MX2 Getting Started Guide Intended Use The OmniScan MX2 is designed to perform nondestructive inspections of industrial and commercial materials. Do not use the OmniScan MX2 for any purpose other
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...
CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.
More informationINSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN
INSTALL GUIDE DOCUMENT NUMBER 25893 REVISION DATE 2627 FIRMWARE AKX-IDS(RS)-BZ1B-[ADS-BZ1] HARDWARE ADS-BZ1 ESSORIES ADS-USB (REQUIRED) COMPATIBLE RF-KIT (OPTIONAL) DIRECTED SMART & ADS-HRN(RS)-SM (OPTIONAL)
More informationGround Control TT Leveling System OWNER'S MANUAL
Ground Control TT Leveling System OWNER'S MNUL TBLE OF CONTENTS System Information 2 Features 2 Safety Information 2 Touch Pad Diagram 3 Operation 4 Basic Jack Operation 4 Unhitching From Tow Vehicle 4
More informationPF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016
PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication
More informationSP PRO KACO Managed AC Coupling
SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load
More informationINTRODUCTION. Specifications. Operating voltage range:
INTRODUCTION INTRODUCTION Thank you for purchasing the EcoPower Electron 65 AC Charger. This product is a fast charger with a high performance microprocessor and specialized operating software. Please
More informationGalvanic Isolator. Instruction Leaflet
G i Galvanic Isolator Gi120-P-SA Instruction Leaflet ote: The isolator is suitable for shore supplies that are protected by an RCD (Earth Leakage Circuit Breaker) with a trip current not exceeding 30mA,
More informationBATTERYLESS JUMP STARTER CAPACITOR INSTRUCTION MANUAL. W 2 AFTER SALES SUPPORT
CAPACITOR BATTERYLESS JUMP STARTER Suitable for vehicles up to: 5L Petrol and 3L Diesel INSTRUCTION MANUAL AFTER SALES SUPPORT AUS 1300 883 104 W 2 www.4x4tough.com.au sales@4x4tough.com.au MODEL: 17-031000
More informationINSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN
INSTALL GUIDE DOCUMENT NUMBER 450 REVISION DATE FIRMWARE IDL-IDS(RS)-BZB-[ADS-BZ] HARDWARE ADS-BZ ESSORIES ADS-USB (REQUIRED) COMPATIBLE RF-KIT (OPTIONAL) DIRECTED SMART & ADS-HRN(RS)-SM0 (OPTIONAL) ADS-TOOLS-MB0
More informationBERMAD Waterworks. Insertion Flow Meter Device (IFM)
IFM-MUT1222PRV BERMAD's IFM-MUT1222-PRV SENSOR is designed for measuring the flow rate of valves sized DN80 to DN600 (3-24 ). This document describes the installation process of the sensor. For larger
More information:43 1/13 Victron & BYD B-Box
2018-11-04 15:43 1/13 Victron & BYD B-Box Victron & BYD B-Box The combination of Victron products with BYD B-Box lithium batteries (2.5, 5.0, 7.5, 10.0 and 12.8 models) has been tested and certified by
More informationOpenEVSE - 40A Charging Station
OpenEVSE - 40A Charging Station P50 Advanced P50 Standard http://www.openevse.com Read and save these instructions prior to installing and operating your Charging Station. Retain this installation guide
More informationDo isolate the power supply from other high power systems such as Stereos and Alarms
Thank you for purchasing a Smart Ride Air Management System, AIRBAGIT.COM s premier flagship product. This system will meet all of your custom and utility needs and will provide you years of trouble free
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9
USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationTable of Contents. Chapter 1 Product Summary... 2
Table of Contents Chapter 1 Product Summary... 2 1.1 Product Profile... 2 1.2 Product Function... 2 1.3 Technical Parameters... 2 1.4 Working Environment Requirement... 3 Chapter 2 Tester Structure...
More informationIntelligent Digital Balance Charger
SURE CHARGE 2000 www.racers-edge.com Intelligent Digital Balance Charger INTRODUCTION Thank you for purchasing the SureCharge 2000 LiPo Balance Charger by Racers Edge. This is a rapid charger with a high
More informationInstallation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount
Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before
More informationPOWER PAK II / PLUS II
POWER PAK II / PLUS II MULTI FUNCTION JUMP STARTERS KP1405 & KP1406 ED2 (December 17) Table of Contents Know Your Product... 2 POWER PAK II Safety Instructions... 3-4 POWER PAK II Care & Charging... 5-6
More informationCHAPTER 2: ELECTRICAL SAFETY
CHAPTER 2: ELECTRICAL SAFETY 2.1 Physiological Effect of Electricity 2.2 Macroshock and Microshock Macroshock Microshock 2.3 Approaches toward Protection against Shock 2.4 Medical Safety Test Electrical
More informationZLogs Help. Tablet Applications. Contents. ZLogs Help
Contents ZLogs Home Screen... 3 What s the difference between certifying logs and verifying edits?... 5 What is the self-check and what if it fails?... 6 How do I check and submit my status logs?... 6
More informationComponents. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.
SRX SERIES Table of Contents - Components - Planning The Install - Mounting - Switched Power - Attach Accessory Harness - Plug In Module - Back-Up Battery - Remote Encoding - 2-Way RFID Remote User Instructions
More informationOPERATING INSTRUCTIONS
RS2-G3 ONE BUTTON 2-WAY REMOTE START SYSTEM OPERATING INSTRUCTIONS CONGRATULATIONS on your choice of a Cool Start Remote Engine Starter and Keyless Entry with DP Technology by Crimestopper Security Products
More informationSupport. EMROL Your power partner
Support Support Part one What is and how to use / upgrade the software / firmware / manual How to start a capacity test Interpreting the results after a test is finished Read out the results with the BITS-software
More informationUSER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4
USER S MANUAL ON-LINE 1K/2K/3KVA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. UPS OPERATION...... 12 6. TROUBLE
More informationSafety Design of CHAdeMO Quick Charging System
Page000855 Abstract EVS25 Shenzhen, China, Nov. 5-9, 2010 Safety Design of CHAdeMO Quick Charging System Takafumi Anegawa Tokyo Electric Power Company R&D Center, Mobility Technology Group 4-1, Egasaki-cho,
More informationDraft Unofficial description of the UNRC charger menus
Table of contents 1. The main screen... 2 2. Charge modes overview... 2 3. Selecting modes... 3 4. Editing settings... 3 5. Choose default charge mode... 4 6. Edit memory banks... 4 7. Charge mode description...
More informationBattery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)
Important: Please ensure that you read and save this instruction manual before using this product. Incorrect operation or misuse of this Battery Booster Pack may damage the equipment or create hazardous
More informationLow Frequency Inverter. User Manual
Pure Sine Wave 220-240V 50-60Hz Low Frequency Inverter User Manual For LK/LW series Power Star inverters only, models: LK2000, LK2000-24, LK3000, LK3000-24, LK3000-48, LK6000-24, LK6000-48 1. Safety precautions
More informationinstall guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN
install guide Document number 13171 Revision Date 231121 firmware OEM-IDS(RS)-BM1-[ADS-BM1] hardware ADS-BM1 accessories ADS-USB (REQUIRED) NOTICE The manufacturer will accept no responsability for any
More informationMAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33
CS ENERGY OPERATIONS PROCEDURE FOR MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33 Responsible Officer: Electrical Services Engineering Manager Responsible Manager: Group
More informationInstallation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current
Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current The Gi50/32/SA withstands fault surges of up to 120a, and is designed for installations connected to shore supplies protected by an
More informationMDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries
MDX-645 Battery Conductance Analyzer For 6 & 12-volt automotive starting batteries INSTRUCTION MANUAL Blank page Contents Safety Guidelines 5 Capabilities 5 Registering Your MDX-Series Tester 7 Display
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationCompact Solar Charger. Model Number ACSC-114 INSTRUCTION MANUAL
Compact Solar Charger Model Number ACSC-114 INSTRUCTION MANUAL AUS 1300 886 649 Model: ACSC-114 Product Code: 45276 03/2015 Welcome Congratulations on choosing to buy a Bauhn product. All products brought
More informationStart UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva
Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE
More informationPortable Power Solutions USER MANUAL
by Portable Power Solutions USER MANUAL Thank you for choosing the Jump Starter 2K/2K by Powercases. Always follow basic safety precautions when using electrical appliances. Before operating your new device,
More informationEV110. Electric Vehicle Supply Equipment Tester. Operating Instructions
Electric Vehicle Supply Equipment Tester Seaward Group USA 6304 Benjamin Road, Suite 506 Tampa Florida 33634 Tel: +44(0)191 5863511 www.seaward-groupusa.com sales@seaward-groupusa.com service@seaward-groupusa.com
More informationElite Power Solutions Automatic Battery Control (ABC) Operation Manual
Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents
More informationPOWERED BY KT71 / Portable Appliance Tester. Instruction Manual
KT71 / Portable Appliance Tester POWERED BY Instruction Manual CONTENTS 1. Safe testing 1 2. Procedure of removing cover.. 3 2.1 Method of removing the cover... 3 2.2 Method of storing the cover... 3 3.
More informationPerformance DSG Upgrade Installation Instructions using the Byteshooter tool version 1.4
Performance DSG Upgrade Installation Instructions using the Byteshooter tool version 1.4 Applies to: 2009+ Volkswagen Golf/Jetta/Beetle/Passat and Similar This will guide you through the steps necessary
More informationAtlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)
Atlas ESR Capacitance and Equivalent Series Resistance Meter Model ESR60 (Enhanced) User Guide Peak Electronic Design Limited 2004/2008 In the interests of development, information in this guide is subject
More informationInstallation and Operating Instructions. MPPT Solar System Controller ISC3040
Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s
More information620 Magnolia Avenue Suite B Ontario, CA (909) Diagnostic and Troubleshooting. Golf Cart. Revision: A Date:
620 Magnolia Avenue Suite B Ontario, CA 91762 (909) 923-1973 Diagnostic and Troubleshooting Golf Cart Revision: A Date: 9-25-13 Diagnostics Diagnostics information can be obtained by observing the fault
More informationDIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:
More informationEV100. Electric Vehicle Supply Equipment Tester. Operating Instructions
Electric Vehicle Supply Equipment Tester Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk
More informationHGM501 Gen-set Controller USER MANUAL. Smartgen Technology
HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...
More informationMegOhmMeter. Users Manual
1550 MegOhmMeter October 2001 Rev.1, 1/03 2001, 2003 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Limited Warranty and Limitation of Liability
More informationUSER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08
USER S MANUAL G SERIES USER S MANUAL Ref.49-MG000EN08 Index USER S MANUAL 1. DESCRIPTION OF THE SERIE G SCALE... 1 1.1. KEYBOARD...1 2. INTRODUCTION... 2 2.1. GENERAL SPECIFICATIONS...2 2.2. OPERATIONAL
More informationLRCD200 Series Combined Loop and RCD Tester USER MANUAL
M LRCD200 Series Combined Loop and RCD Tester USER MANUAL G SAFETY WARNINGS Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use.
More informationInstallation and Operating Instructions. Solar System Controller ISC3030
Installation and Operating Instructions Solar System Controller ISC3030 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of the
More informationThunder Power Tarp Kit Operation
Thunder Power Tarp Kit Operation Dual Arm Curb Side Stowing Single Arm Curb Side Stowing 011-52476 Rev. H P a g e 2 In this booklet you will find: OPERATING INSTRUCTIONS... 3 Powering up or down the system...
More informationRescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference
Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More information