Noise Control of Marine Gas Turbines in Propulsion and Auxiliary Power Applications

Size: px
Start display at page:

Download "Noise Control of Marine Gas Turbines in Propulsion and Auxiliary Power Applications"

Transcription

1 74-GT-110 Copyright 1974 by ASME $3.00 PER COPY The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its Divisions or Sections, or printed in its publications. Discussion is printed only if the paper is published in an ASME journal or Proceedings. Released for general publication upon presentation. Full credit should be given to ASME, the Professional Division, and the author (s). $1.00 TO ASME MEMBERS Noise Control of Marine Gas Turbines in Propulsion and Auxiliary Power Applications M. I. SCHIFF Vice President, Special Products Department, Industrial Acoustics Co., Inc., Bronx, N. Y. Mem. ASME While techniques for silencing gas turbines have been applied with great success to numerous land systems, only limited experience has been gained aboard ship. The silencing of ship board gas turbines is made more complex due to the unique problems imposed by the effects of a sea air environment as well as the necessity for minimization of dead load and limitations on available space. The purpose of this paper is to review the state-of-the-art in gas turbine silencing specifically in relation to marine applications, Experiences in silencing the main propulsion system aboard the Adm. Wm. M. Callaghan, Military Sea Transport Service Roll- On/Roll-Off Cargo Ship and the Auxiliary Power units aboard the Royal Canadian DDH-280 Destroyers are described. Contributed by the Gas Turbine Division of The American Society of Mechanical Engineers for presentation at the Gas Turbine Conference & Products Show, Zurich, Switzerland, March 30-April 4, Manuscript received at ASME Headquarters November 21, Copies will be available until December 1, THE AMERICAN SOCIETY OF MECHANICAL. ENGINEERS, UNITED ENGINEERING CENTER, 345 EAST 47th STREET, NEW YORK, N.Y

2 Noise Control of Marine Gas Turbines in Propulsion and Auxiliary Power Applications M. I. SCHIFF INTRODUCTION The increased utilization of gas turbines as a means of propulsion and auxiliary power for marine applications has created a need to control the noise generated by this equipment. It is the purpose of this paper to illustrate areas of experience in the silencing of gas turbines aboard ship, and to outline the procedures to follow in order to satisfy the stringent sound requirements that are being imposed for shipboard spaces. Specific references will be made to silencing achievements and applications aboard the "Admiral Wm. M. Callaghan" Military Sea Transport Service (Roll-On/Roll-Off) Cargo Ship, the U. S. Coast Guard Ice Breaker "Polar Star," the Canadian Navy DDH Class Helicopter Destroyers, and the U. S. Navy DD963 "Spruance" Class Destroyers. Whether for a land base or shipboard application, there are three major areas that must be considered in the silencing of gas turbines. Specifically, one must be concerned with the noise associated with the gas turbine intake, exhaust and casing. Gas turbine intake noise is predominantly high frequency in nature and is created by high velocity air passing over the blades in the compressor sections. The gas turbine exhaust noise is essentially broad band in spectrum, and is generated by the combustion process together with the airflow noise created in the power turbine. Casing radiated noise is the combination of all noise generated in the gas turbine. Due to losses through the turbine structure, this noise is usually decibels lower in sound power output to that of the gas turbine inlet and exhaust noise. with them individually or as a group. Usually, the engine enclosure and any related ventilation silencing are designed for the combined effects of intake, exhaust and casing radiated noise, while the intake and exhaust silencers are designed primarily for the noise generated by those respective components. Since in most ships the propulsion and auxiliary power systems are located at the lower deck levels, noise control considerations must also be applied to the duct systems that supply and discharge engine air. Furthermore, while most land base gas turbines have been designed for far field noise control requirements, (that is, for situations where the potential noise receiver is more than 100 ft away from the gas turbine), marine gas turbine noise control measures are generally required to satisfy near field criterion. Unlike the land base gas turbine, the noise generator and the receiver are in close proximity. As a result, means of natural attenuation such as directivity and divergence provide a very small component of the total noise reduction that may be required. The approach to follow in most shipboard systems can be briefly outlined as follows: 1 Select applicable criterion for shipboard space being considered. 2 Estimate unsilenced sound levels in the space in question. 3 If unsilenced levels exceed applicable criterion considered, take necessary steps to silence the component or components contributing to the excessive noise levels. SELECTION OF SILENCING EQUIPMENT FOR MARINE GAS ACCEPTABLE NOISE CONTROL CRITERIA ABOARD SHIP TURBINES Marine gas turbine silencing systems as In the silencing of gas turbine noise aboard well as land based gas turbines silepcing systems ship, one must consider each of these three are designed to satisfy comfort and hearing noise sources and attack the problems associated damage criteria. In addition, as aural communi- 1

3 SHIP SPACE CATEGORY *-- Table 1 Noise Level Criteria for Ship Spaces in Decibels Octave Band Center Frequencies, Hz SIL VALUE A SIL Value Requirement B C D E SIL Value Requirement F SIL Value Requirement Table 2 Approximate Sound Power Level of Marine Gas Turbine in Decibels, Re: Watts Octave Band Center Frequencies, Hz o o,-.1 m a,-1 '--j rp4 o o el 0 S-1 o a. m m z 0 cs,..-1 m Inlet Exhaust Casing i.: Z o 0 m. m a 8 a r.., i H a.4 A S p m a 0 Inlet Exhaust X Casing cation is essential for efficient ship operation, permissible sound levels for shipboard spaces are also dependent upon speech intelligibility requirements. While numerous studies have been conducted pertaining to the physiology and psychology of speech, hearing and comfort, it is difficult to provide a general criterion that will satisfy all requirements and a compromise must be reached. An acceptable compromise for airborne noise levels aboard ships is indicated in "General Specification for Ships of the U. S. Navy Department of Navy" dated January This specification is a workable one, as the operations that are carried out aboard ship have been carefully considered and the criterion established with ship spaces in mind. The type of spaces aboard ship are classified as follows: Category A: Spaces, other than category E spaces, where intelligible speech communication is necessary. Category B: Spaces where comfort of personnel in 2

4 1. POWER-FLOW INLET SILENCER 2. POWER-FLOW EXHAUST SILENCER 3. VENTILATION SILENCER 4. ENGINE ENCLOSURE 5. REDUCTION GEAR ENCLOSURE 6. ACOUSTICALLY TREATED INLET DUCT 7. ACOUSTICALLY TREATED EXHAUST DUCT Fig. 1 General arrangement of noise control system for typical gas turbine powered ship Category C: Category D: Category E: Category F: their quarters is normally considered to be an important factor. Spaces where it is essential to maintain especially quiet conditions. Spaces or areas where a higher noise level is expected and where deafness avoidance is a greater consideration than intelligible speech communication. High noise level areas where intelligible speech communication is necessary. Topside operating stations on weather decks where intelligible speech communication is necessary. The governing factor in Categories A, E and F is speech intelligibility. For those spaces, Speech Interference Levels (SILO limits are used to specify acceptable levels. Speech Interference Level, SIL is a measure of the effect of background noise on intelligible speech communication and numerically is the arithmetic average of the sound pressure level in decibels of the octave bands with center frequencies at 500, 1000 and 2000 Hz. For all other categories the permissible airborne noise levels are specified in each octave band in decibels. The noise level criteria for categories A to F including the SIL requirements are shown in Table 1. UNSILENCED SOUND LEVELS OF MARINE GAS TURBINES The accuracy of any acoustical analysis is 1. NARROW THROAT 4. EVASE EXIT 7. HEAVY PUNCHED FLANGES 2. STRAIGHT ACOUSTICAL 5. RUGGED BRACED HOUSING &SOLID ROUNDED NOSE PASSAGE 6. COMPRESSED LONG FIBER 3. CONTROLLED ANGLE BLANKET S. BELL MOUTH ENTRY Fig. 2 Cut-away view of a typical rectangular power-flow silencer limited by the reliability of the sound level data of the noise source. While it is possible to theoretically estimate the noise levels generated by a gas turbine and, in some case, this approach provides usable data, there is no substitute for actual Sound Power Levels of operating equipment. Whenever possible, this information should be obtained and guaranteed by the engine manufacturer. If the analysis is a preliminary one and the engines have not been selected, the Sound Power Level (PWL) data presented in Table 2 for 3

5 POWER-FLOW INLET SILENCERS MODU LINE NOISHIELD ENCLOSURE POWER-FLOW EXHAUST SILENCERS Fig. 3 Admiral Wm. M. Callaghan main propulsion gas turbine silencing system 25,000 H-P Main Propulsion Gas Turbine engines and 3500 H-P Auxiliary Power Gas Turbines may be used. The results obtained from using these data will generally prove to be conservative. NOISE CONTROL OF MARINE GAS TURBINES Once the noise levels have been determined and the selection of acceptable levels has been established, it is possible to select the appropriate noise control equipment required. A noise control system as indicated in Fig. 1 will, in most instances, assure satisfactory acoustic and aerodynamic operation of a gas turbine engine. Such a system will consist of the following silencing components for main propulsion or auxiliary power gas turbines: 1 Air Inlet Silencer 2 Exhaust Gas Silencer 3 Engine Enclosure 4 Ventilation Air Inlet Silencer 5 Air Inlet Duct Lagging 6 Exhaust Gas Duct Lagging 7 Reduction Gear/Generator Enclosure This silencing equipment should be designed for a 20-yr useful life, with due consideration given to the deterious effects that a marine environment will have on most materials of construction. The conditions of high temperature and high velocity that land gas turbine exhaust silencers are normally subjected to must also be considered. To ensure maximum effectiveness of the space available for silencing, experience dictates the utilization of splitter type silencers for the inlet, exhaust, and ventilation units. This type of silencer enables the noise control engineer to obtain an optimum balance between aerodynamic pressure loss and noise reduction since it is possible to minimize the aerodynamic losses across the silencer while developing the maximum noise reduction in the available space envelope. Fig. 2 illustrates a typical silencer element. The maximum effectiveness of a silencer is obtained by locating it as close as possible to the engine itself. This means placement at the base of the inlet and exhaust ducts. The location on deck where the inlet and exhaust openings are ducted are generally the area of acoustic concern and control the engine inlet and exhaust designs. The engine enclosure is a prefabricated structure that serves as a housing for the engine. It is constructed of sound absorbing panels designed to minimize build up of noise within the enclosure as well as to provide the required transmission loss across the walls. Doors, hatches, and piping penetrations must be designed to be compatible with the noise reduction provided by the basic panel enclosure. The reduction gear or generator enclosure is usually fabricated of the same type of acoustic structure as that of the engine housing. In both cases, these enclosures must provide accessibility to equipment, as well as to allow for removability of all components when required. Allowable levels in the engine room control the noise control design of the engine enclosure. It has generally been found that the exhaust duct design that offers the required heat loss across its walls, provides the necessary noise reduction required for satisfactory operation. In any event, both the inlet and exhaust ducting systems must be designed to ensure acceptable noise levels in the varied compartments adjacent to the ducting system path. This is accomplished by means of a double walled acoustical panel forming the basic structural element of the duct system. 4

6 Table 3 Dynamic Insertion Loss of Typical Ship Board Main Propulsion Gas Turbine Silencers, Decibels SHIP COMPONENT SILENCED Octave Band Center Frequencies, Hz Callaghan Inlet Callaghan Exhaust Polar Star Inlet DD963 Inlet DD963 Exhaust SILENCING THE ADMIRAL WM. M. CALLAGHAN MAIN PROPULSION GAS TURBINE The Admiral William M. Callaghan "Roll-On/ Roll-Off" Cargo ship, when commissioned in October 1967, was the worldls fastest and largest gas turbine powered merchant vessel. This 24,000 ton ship which is 696 ft in length is capable of speeds of 25 knots. The Callaghan was originally powered by two 25,000 H-P Pratt & Whitney FT 4A-2 gas turbine engines. These engines were subsequently replaced by General Electric Company Model LM-2500 Gas Turbines. However, the silencing system which was designed for operation with the Pratt & Whitney engines also proved aerodynamically and acoustically acceptable for the G.E. engines. Minor modifications were made to the engine enclosure to adapt to the physical difference of the silencers located in the engine inlet duct. The silencers were split into two modules to make removal between deck levels possible. The silencer was an all-welded fabrication with all steel surfaces galvanized to minimize corrosion. Parallel baffle type silencers were also employed to minimize engine exhaust noise. All steel components in the exhaust silencer were fabricated from hot rolled steel. The inlet and exhaust silencers were each designed to satisfy deck side requirements while the engine enclosure was designed to satisfy requirements in the engine room. The inlet system design was controlled by the requirement at the deck house for a sound pressure level not to exceed the sound pressure levels established by Category "B" of the U. S. Navy specification for noise and vibration aboard ship. Octave Band Center Frequency, Hz Allowable Sound Pressure Level, db, Re: Dynes/cm o o two engines. The Callaghan noise control system consists of inlet silencer, exhaust silencer, and engine enclosure for each of the engines. The system is shown schematically in Fig. 3. Silencing of the engine inlet noise is achieved by two stages of straight splitter The exhaust silencer was designed so that sound levels at topside operational stations were limited to a Speech Interference Level of 55. The exhaust system ducted 30 ft above the deck helped to minimize the length of exhaust treatment required. Dynamic Insertion Loss of the inlet and exhaust silencers is tabulated in 5

7 Table 4 Noise Reduction of Typical Marine Gas Turbine Engine Enclosures, Decibels SHIP Octave Band Center Frequencies, Hz Callaghan DDH DD963 Main Propulsion DD963 Auxiliary Power ENGINE INLET SILENCER 2. VENTILATION INLET SILENCER 3. ENGINE EXHAUST SILENCER 4. VENTILATION EXHAUST SILENCER 5. MODULINE ENGINE ENCLOSURE Fig. 4 Silencing system for the DDH-280 ship's service gas turbines Table 3. The engine enclosure was designed to satisfy Category "B" of specification in the engine room. Table 4 illustrates the noise reduction levels necessary to maintain this requirement. SILENCING THE DDH-280 SHIP'S SERVICE GAS TURBINES The four Canadian Armed Forces DDH-280 "Tribal Class" helicopter destroyers are considered the finest anti-submarine destroyers presently afloat. Displacing 4500 tons, these ships are equipped with the most sophisticated underwater surveillance and communications systems. Ship's service aboard this vessel are provided by four Solar, Division of International Harvester Company, Model T "Saturn" gas turbine engines. These generators provide enough power to supply a small city with all of its electrical power requirements. The DDH-280 class destroyers were designed to be among the quietest ships afloat, an obvious tactical advantage during anti-submarine missions. These gas turbines were designed in accordance with the Royal Canadian Navy's Specification for 6

8 Table 5 Dynamic Insertion Loss of Typical Ship Board Auxiliary Power Gas Turbine Silencers, Decibels SHIP COMPONENT SILENCED Octave Band Center Frequencies, Hz DDH-280 Inlet DDH-280 Exhaust DD963 Inlet DD963 Exhaust "Air Borne Noise Criteria for Shipboard Spaces." The specification for individual silencing components is tabulated below: thickness. This 11,000 ton CODOG-electric vessel is 400 ft in length and is the first icebreaker to be built in the United States since Sound Pressure Level, db Octave Band Center Frequency, Hz ft from inlet '3 ft from exhaust o eu3 ft from enclosure The complete noise control system for one of the ship's service gas turbines is illustrated in Fig. 4. The system consists of inlet silencer, engine exhaust silencer, ventilation air exhaust silencer and enclosurê. The intake silencer is somewhat unusual in that it is divided to draw air into the engine as well as cooling air into the engine enclosure. All steel surfaces in the air or gas stream are fabricated from type 304 stainless steel. Tables 4 and 5 summarize the acoustical performance provided by each of the silencing components. SILENCING THE ICEBREAKER "POLAR STAR" BOOST GAS TURBINES The U. S. Coast Guard "Polar Star" is intended to be the world's most powerful icebreaker having the capacity to ram through ice 21 ft in Boost power for breaking through ice is provided by three 25,000 H-P Pratt & Whitney FT 4A-12 marine gas turbines. The gas turbines are geared to independent shafts and are used for limited periods in thick ice fields when more than 18,000 H-P per shaft is required. The silencing provided for each gas turbine is as illustrated in Fig. 5. Only inlet silencing is required to meet the U. S. Coast Guard's noise criterion for this vessel. With all engines in operation, the noise levels at the inlet duct entrance will not exceed 90 dba. Table 3 indicates the silencer Dynamic Insertion Loss necessary to satisfy that specification. Due to space limitations on this vessel, the inlet silencers were designed to conform with the elliptical shape of the ship's inlet ducting. The straight splitter silencers employed were fabricated as three separate elements as shown. 7

9 POWER-FLOW INLET SILENCER POWER-FLOW INLET SILENCER VENTILATION SILENCER Fig. 5 Inlet silencer system for the U. S. Coast Guard icebreaker "Polar Star" boost gas turbines POWER-FLOW EXHAUST SILENCER Fig. 6 DD-963 main propulsion gas turbine silencing system SILENCER TURBINE SECTION ROOF PANEL GEARBOX SECTION ROOF PANELS TURBINE SECTION END WALL OVER PRESSURE RELIEF PANEL GEARBOX SECTION END WALL BLOW IN PANEL PANEL ACCESS PLUG TURBINE SECTION SIDE WALL CI I MAIN COUPLING REMOVAL ACCESS PLUG ACCESS PLUG GEARBOX SECTION SIDEWALL 8 Fig. 7 Enclosure for the DD-963 auxiliary power gas turbine engines

A Different Approach to Gas Turbine Exhaust Silencing

A Different Approach to Gas Turbine Exhaust Silencing 74-GT-26 Copyright 1974 by ASME $3.00 PER COPY $1.00 TO ASME MEMBERS The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of

More information

Hydraulic Starting of Marine Gas Turbine Engines

Hydraulic Starting of Marine Gas Turbine Engines 68-GT-29 The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its Divisions or Sections, or printed in its publications.

More information

DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA. Y. K. Tso and R. G. Juniper

DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA. Y. K. Tso and R. G. Juniper FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA Invited Paper A STUDY OF THE TRANSMISSION OF NOISE AND VIBRATION IN AN ALUMINIUM MOTOR VESSEL Y. K. Tso

More information

SILENCER SELECTION INSTRUCTIONS

SILENCER SELECTION INSTRUCTIONS For general information in HVAC Acoustics, consult the following publications: 2013 ASHRAE Fundamentals Handbook, Chapter 8 Sound and Vibration 2011 ASHRAE Applications Handbook, Chapter 48 Noise and Vibration

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Sound Application Guide: Description and Ratings

Sound Application Guide: Description and Ratings Sound Application Guide: Description and Ratings AHRI SOUND STANDARD: DESCRIPTION AND RATINGS Table of Contents Overview..........................................................................4 AHRI

More information

(VTOL) Propulsion Systems Design

(VTOL) Propulsion Systems Design 72-GT-73 $3.00 PER COPY $1.00 TO ASME MEMBERS The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its Divisions or Sections,

More information

SILENCER SELECTION INSTRUCTIONS

SILENCER SELECTION INSTRUCTIONS SILENCER SELECTION INSTRUCTIONS For general information in HVAC Acoustics, consult the following publications: > > 07 ASHRAE Fundamentals Handbook, Chapter 8 Sound and Vibration > > 05 ASHRAE Applications

More information

Compressor Noise Control

Compressor Noise Control Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1972 Compressor Noise Control G. M. Diehl Ingersoll-Rand Research Follow this and additional

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Pneumatic Starting Systems

Pneumatic Starting Systems $1.50 PER COPY 75C TO ASME MEMBERS The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its 67-GT-15 Divisions or Sections,

More information

MSC Guidelines for Fuel Oil Systems

MSC Guidelines for Fuel Oil Systems P. W. Gooding, CDR, Chief, Engineering Division References: Contact Information: a. 46 CFR 56.50-60 Systems containing oil (Subchapter F) b. 46 CFR 56.50-65 Burner fuel-oil service systems (Subchapter

More information

MULTITHREADED CONTINUOUSLY VARIABLE TRANSMISSION SYNTHESIS FOR NEXT-GENERATION HELICOPTERS

MULTITHREADED CONTINUOUSLY VARIABLE TRANSMISSION SYNTHESIS FOR NEXT-GENERATION HELICOPTERS MULTITHREADED CONTINUOUSLY VARIABLE TRANSMISSION SYNTHESIS FOR NEXT-GENERATION HELICOPTERS Kalinin D.V. CIAM, Russia Keywords: high-speed helicopter, transmission, CVT Abstract The results of analysis

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. LINE SILENCER Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. PRODUCT GUIDE PULSCO LINE SILENCER TABLE OF CONTENTS DESCRIPTION PAGE PULSCO LINE

More information

VENT SILENCER PRODUCT GUIDE

VENT SILENCER PRODUCT GUIDE VENT SILENCER Copyright 200 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. PRODUCT GUIDE PULSCO VENT SILENCER TABLE OF CONTENTS DESCRIPTION PAGE PULSCO VENT

More information

Electric Drive - Magnetic Suspension Rotorcraft Technologies

Electric Drive - Magnetic Suspension Rotorcraft Technologies Electric Drive - Suspension Rotorcraft Technologies William Nunnally Chief Scientist SunLase, Inc. Sapulpa, OK 74066-6032 wcn.sunlase@gmail.com ABSTRACT The recent advances in electromagnetic technologies

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

SILENT MV Ultra Quiet In-line Fans

SILENT MV Ultra Quiet In-line Fans Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent

More information

Prof. João Melo de Sousa Instituto Superior Técnico Aerospace & Applied Mechanics. Part B Acoustic Emissions 4 Airplane Noise Sources

Prof. João Melo de Sousa Instituto Superior Técnico Aerospace & Applied Mechanics. Part B Acoustic Emissions 4 Airplane Noise Sources Prof. João Melo de Sousa Instituto Superior Técnico Aerospace & Applied Mechanics Part B Acoustic Emissions 4 Airplane Noise Sources The primary source of noise from an airplane is its propulsion system.

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL Vent/Fan Silencers Vent/Fan Silencers UNIVERSAL ENERGY ENVIRONMENTAL 4.1 4.1 Rotary Positive Blower Silencers HV Series Combination Easy To Specify and Order Vent and blowdown silencers are rarely a simple

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

ARCHIVED REPORT. Daihatsu DT Series. Outlook. Orientation. Industrial & Marine Turbine Forecast - Gas & Steam Turbines

ARCHIVED REPORT. Daihatsu DT Series. Outlook. Orientation. Industrial & Marine Turbine Forecast - Gas & Steam Turbines Industrial & Marine Turbine Forecast - Gas & Steam Turbines ARCHIVED REPORT For data and forecasts on current programs please visit www.forecastinternational.com or call +1 203.426.0800 Outlook DT Series

More information

Quiet-Duct Conic-Flow Silencers Section Specifications

Quiet-Duct Conic-Flow Silencers Section Specifications Quiet-Duct Conic-Flow Silencers Section 15000 Specifications 1.01 General A. Furnish and install Conic-Flow (tubular) silencers of the types and sizes shown on the plans and/or listed in the schedule.

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

Application of Gas Turbine Power to Oilwell Service Pumping

Application of Gas Turbine Power to Oilwell Service Pumping The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its 70-GT-69 Divisions or Sections, or printed in its publications.

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information

TOP 10 NOISE CONTROL TECHNIQUES

TOP 10 NOISE CONTROL TECHNIQUES TOP 10 NOISE CONTROL TECHNIQUES The following are 10 simple noise control techniques that have wide application across the whole of industry. In many cases, they will produce substantial noise reductions

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

SILENCERS. Contents. Page No. Features, Description, Sizes and Options. Performance Data. Submittal Data Request Sheet

SILENCERS. Contents. Page No. Features, Description, Sizes and Options. Performance Data. Submittal Data Request Sheet Contents Page No. Features, Description, izes and Options Rectangular Dissipative ilencers RBB-LP Rectangular Broad Band - Low Pressure Insertion Loss RBB-MP Rectangular Broad Band - Medium Pressure Insertion

More information

Installation Requirements for Small Gas Turbine Engines

Installation Requirements for Small Gas Turbine Engines THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47 St, New York, N.Y. 10017 85-IGT-151 The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

Architectural Louvers

Architectural Louvers Architectural Louvers Introduction AWV is headquartered in Holland, Ohio and is part of the Mestek Architectural Group. In addition to AWV, Mestek s Architectural activities include Linel and a strategic

More information

FXV/CXV & FXV3/CXV3 Layout Guidelines

FXV/CXV & FXV3/CXV3 Layout Guidelines FXV/CXV & FXV3/CXV3 Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Rosemex Products 96 VENTILATION INDUCTION UNIT

Rosemex Products 96 VENTILATION INDUCTION UNIT 10 Rosemex Products 96 VENTILATION INDUCTION UNIT 1 INDEX Unit features... 1-4 Nomenclature... 5 System comments... 5 Selection procedures... 5-6 Vertical selection tables... 7-12 Low Vertical selection

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INTERIOR NOISE OF A KOREAN HIGH-SPEED TRAIN IN TUNNELS

INTERIOR NOISE OF A KOREAN HIGH-SPEED TRAIN IN TUNNELS INTERIOR NOISE OF A KOREAN HIGH-SPEED TRAIN IN TUNNELS Sunghoon Choi, Chan-Woo Lee, Jae-Chul Kim, and Joon-Ho Cho Noise and Vibration Research Group, Korea Railroad Research Institute, Woulam-dong, Uiwang-city,

More information

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL Absorptive Silencers s UIVERSAL EERGY EVIROMETAL The absorptive type silencer is the classic dissipative design that absorbs noise energy by the use of various types of fibrous packing materials. As sound

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3 , Sound attenuating louvres Rectangular sound attenuators DZ-2, DZ-3 Application are designed to attenuate noises of fans and air-conditioning devices in ventilation and air-conditioning installations.

More information

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Cylindrical Silencers

Cylindrical Silencers Cylindrical Silencers A200 Series and 300 Series Installation and Operation Manual Rev. B (c) Copyright 2012, GT Exhaust, Inc. All Rights Reserved Published: April 30, 2012 NOTICE The instructions herein

More information

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

Poulsen Hybrid Monorotor

Poulsen Hybrid Monorotor Poulsen Hybrid Monorotor The Poulsen Hybrid Monorotor A Novel Approach to Flettner Marine Propulsion January 2012 Background The Magnus effect defines thrust developed by spinning a cylinder in an air

More information

For Yachts Innovative Gear Solutions in Naval Propulsion Systems

For Yachts Innovative Gear Solutions in Naval Propulsion Systems For Yachts Innovative Gear Solutions in Naval Propulsion Systems CODAD gear box Type BSL 2 x 130/140 during final assembly. Philosophy The basic factors for a long lasting success in the production of

More information

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief Gravity Ventilators Models FGI and FGR Fabra Hood Intake and Relief July 008 Page Fabra Header Hood Greenheck Fabra Hoods are designed for intake (Model FGI) or relief (Model FGR) applications with either

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

Eaton India Engineering Center & IIT Madras Research & Technology Collaboration

Eaton India Engineering Center & IIT Madras Research & Technology Collaboration Eaton India Engineering Center & IIT Madras Research & Technology Collaboration Sudhakar Potukuchi, PhD VP Engineering Srinivas Mutukuri, PhD Head, Corporate Research & Technology Nikhil Tambe, PhD Manager,

More information

A Complete Line of Quality Products for Marine Applications

A Complete Line of Quality Products for Marine Applications american warming and ventilating A Mestek Company A Complete Line of Quality Products for Marine Applications 1 About AWV Marine Dampers At American Warming and Ventilating, we are committed to design

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

Subject: ARRV Underwater Radiated Noise Design Limit Date: 29 July, 2008

Subject: ARRV Underwater Radiated Noise Design Limit Date: 29 July, 2008 Subject: ARRV Underwater Radiated Noise Design Limit Date: 29 July, 2008 References: 1. UNOLS Science Mission Requirements dated 2000/2001 2. ICES Cooperative Research Report No. 209 3. Measurement of

More information

Fuel Problems With Marine Gas Turbine Engines

Fuel Problems With Marine Gas Turbine Engines r 67-GT-5 2 The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its Divisions or Sections, or printed in its publications.

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL Wall air diffusers with discs for supply air and flush mounting General Rectangular supply air diffusers with rotatable discs. The disc technique enables supply of air above or below room temperature as

More information

U.S.C.G. Polar Star Combination of a Diesel Electric Propulsion Plant with a Geared Gas Turbine Boost Plant

U.S.C.G. Polar Star Combination of a Diesel Electric Propulsion Plant with a Geared Gas Turbine Boost Plant 73-GT-73 $3.00 PER COPY $1.00 TO ASME MEMBERS The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the Society or of its Divisions or Sections,

More information

Net +Plus Connection Code

Net +Plus Connection Code Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at

More information

SEASPRITE. SH-2G Super MODERN MARITIME SOLUTION

SEASPRITE. SH-2G Super MODERN MARITIME SOLUTION SEASPRITE SH-2G Super MODERN MARITIME SOLUTION Flexible The Kaman SH-2G Super Seasprite is the ideal multimission maritime helicopter. From anti-submarine warfare, to anti-surface warfare, over-the-horizon

More information

GT-Suite Users Conference

GT-Suite Users Conference GT-Suite Users Conference Thomas Steidten VKA RWTH Aachen Dr. Philip Adomeit, Bernd Kircher, Stefan Wedowski FEV Motorentechnik GmbH Frankfurt a. M., October 2005 1 Content 2 Introduction Criterion for

More information

to obtain the specified voids due

to obtain the specified voids due ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

Reliable, Silent, Efficient. Voith Linear Jet

Reliable, Silent, Efficient. Voith Linear Jet Reliable, Silent, Efficient. Voith Linear Jet 1 A New Propulsion Standard. The Voith Linear Jet (VLJ) combines the best elements of two existing technologies conventional screw propellers and water jets.

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

About TECO-Westinghouse

About TECO-Westinghouse About TECO-Westinghouse Th e TECO-WESTINGHOUSE l e g ac y o f i n n ovat i o n a n d q ua l i t y in the design and production of electric motors and generators for the marine industry spans more than

More information

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction e t International Journal on Emerging Technologies 7(1): 37-41(2016) ISSN No. (Print) : 0975-8364 ISSN No. (Online) : 2249-3255 Performance of Extended Inlet and Extended Outlet Tube on Single Expansion

More information

USA FALCON 1. Fax: (310) Telephone: (310) Fax: (310) Telephone: (310) Fax: (310)

USA FALCON 1. Fax: (310) Telephone: (310) Fax: (310) Telephone: (310) Fax: (310) 1. IDENTIFICATION 1.1 Name FALCON 1 1.2 Classification Family : FALCON Series : FALCON 1 Version : FALCON 1 Category : SPACE LAUNCH VEHICLE Class : Small Launch Vehicle (SLV) Type : Expendable Launch Vehicle

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

S-65 S-65. Oct (203) I I (203) Newsletter The Igor I. Sikorsky Historical Archives Inc. All rights reserved.

S-65 S-65. Oct (203) I I (203) Newsletter The Igor I. Sikorsky Historical Archives Inc. All rights reserved. S-65 S-65 S-65 (H-53) The heavy lift helicopter was launched in 1962 with the U.S. Marines CH-53A for combat assault missions. The U.S. Navy RH-53 minesweeping and U.S. Air force HH-53 combat air rescue

More information

RETROFIT TERMINAL UNITS

RETROFIT TERMINAL UNITS GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable

More information

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018 References C. J. Robuck, LCDR, Chief, Engineering Division a. 46 CFR Part 52 Power Boilers b. 46 CFR Part 54 Pressure Vessels c. 46 CFR Part 63 Automatic Auxiliary Boilers Contact Information If you have

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants Page 1 of 8 Compiled by Approved by Chief Examiner Syllabus Committee: 26 February 2013 OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE Deck: Page 2 of 8 KNOWLEDGE, UNDERSTANDING

More information

Acoustic design of the air transparent soundproofing wall

Acoustic design of the air transparent soundproofing wall PROCEEDINGS of the 22 nd International Congress on Acoustics Materials for Noise Control: Paper ICA2016-323 Acoustic design of the air transparent soundproofing wall Seong-Hyun Lee (a), Junghwan Kook (b),

More information

Mancoolers Models MCY, MCB, MCP

Mancoolers Models MCY, MCB, MCP Mancoolers s MCY, MCB, MCP October 2007 Mancoolers Greenheck MC Mancooler fans are direct drive, tube axial fans designed for applications where localized air direction and circulation are required. Mancoolers

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions Sound attenuating exterior wall grille QUICK FACTS Excellent noise attenuation A robust grille that withstands severe climatic conditions Available in a number of different materials Technical description

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Design and Test of Transonic Compressor Rotor with Tandem Cascade Proceedings of the International Gas Turbine Congress 2003 Tokyo November 2-7, 2003 IGTC2003Tokyo TS-108 Design and Test of Transonic Compressor Rotor with Tandem Cascade Yusuke SAKAI, Akinori MATSUOKA,

More information

MSC Guidelines for Steering-Gear Electrical Systems

MSC Guidelines for Steering-Gear Electrical Systems S. T. Brady, CDR, Chief of Engineering Division Purpose: This document outlines basic guidance for submitting steering-gear control and alarm system drawings for vessels meeting the requirements of 46

More information

Turbocharging: Key technology for high-performance engines

Turbocharging: Key technology for high-performance engines Engine technology Turbocharging: Key technology for high-performance engines Authors: Dr. Johannes Kech Head of Development Turbocharging Ronald Hegner Team Leader, Design of Turbocharging Systems Tobias

More information

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide PELICANTM Wall Rectangular perforated wall air diffusers for supply air Quick facts Flexible air distribution pattern, easy to set Cleanable, removable damper Simple commissioning, fixed measurement tapping

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information