YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER
|
|
- Brendan Palmer
- 5 years ago
- Views:
Transcription
1 A wide range of desuperheaters, pneumatic actuators, strainers to satisfy all specifications of the power, pulp and paper industry and process gas applications FEATURES Fabricated construction Special design for small steam lines with minimal steam pressure losses Steam control within 6 C of saturation temperature and ± 1% of controller range Venturi type vena contracta Wide range of C v (K v ) capacities Pressure class and connections: - ASME B16.34 class 150 to EN class PN 16 to PN butt weld connections to ASME B16.25 or EN-ISO 9692 Materials - ASTM SA 182 F11 / SA 335 P11 - or EN other materials upon request GENERAL APPLICATION Turbine gland sealing Air ejectors Nox steam for gas turbines House steam Drum dryers Tire molds Vulcanizing equipment and cooking kettles TECHNICAL DATA Sizes: Steam NPS 1½ - 4 (DN ) Water NPS ½ - 1 (DN 15-25) Emerson. All Rights Reserved. VCTDS US 16/12
2 Water inlet Water pipe nipple is available to various standards. Construction in accordance to ANSI, DIN, JIS and BS Water inlet flange is available to various standards ANSI NPS ½ - 1 DIN DN Body is available in various materials. Construction in accordance to ANSI, DIN, JIS and BS Steam connection, in a wafer design, raised face or butt weld: ANSI NPS 1½ - 4 DIN DN Water channel in body bore Diverging venturi contour Converging venturi contour Water spray port elliptical shape Steam flow Water swirl chamber Steam venturi insert Water tangential slot FIGURE 1 2
3 The Small Pipe Inline Desuperheater (SPID) has been specifically designed to provide precise steam temperature control in small steam lines. In process applications where control of the product temperature is critical to the final quality, it is essential that fine steam temperature control is maintained. The pressure reduction of saturated steam in throttling valves often results in a lower pressure superheated steam. This superheated steam has a lower heat transfer capability than the saturated state resulting in decreased production. High superheat temperatures can also damage the product or heat exchanger components. The SPID Desuperheater offers a reliable economical solution for steam temperature control in process and utility applications. This is achieved by creating atomized water droplets sprays and injecting them into small steam lines with minimal steam pressure losses. These atomized water droplets have high surface to volume ratios encouraging rapid heat transfer. Rapid vaporization occurs for efficient cooling of the superheated steam without the need for pipe liners. CODES AND STANDARDS The SPID Desuperheater is designed and manufactured to meet a wide variety of international codes and standards. Certified acceptance documents are available upon request. If special codes or standards are required by your local authority, then we would be pleased to discuss them. SYSTEM COMPARISON Conventional Conventional injection water systems consist of: Fixed size spray nozzle Control valve Steam pipe section The steam passes through a vena contracta. The upstream side is a high recovery (low loss) converging contour where velocity and resulting turbulence increase. The downstream side is a rapidly diverging contour causing separation of the steam flow from the boundary surface. This separation provides space for the emerging water spray pattern to fully develop and mix with the steam thereby avoiding thermal shock to downstream piping. Cooling water is monitored into the SPID by a temperature control valve (TCV). The TCV responds to the output signal of a temperature indicating controller (TIC) connected to the downstream temperature sensor/transmitter (TT). Modulation of the TCV varies the amount of water entering the SPID (see figure 2). Cooling water entering through the SPID s water flange connection travels to the water channel which runs circumferentially around the body bore. Multiple water slots in the outer surface of the nozzle insert will tangentially deliver the water into the swirl chamber. The swirl chamber s conical shape forms a converging section that accelerates the rotating water. It then passes through a constant bore for stabilization. The rotating high velocity water exits through what is an elliptical shape in the surface of the diverging side of the steam nozzle. This shape effectively causes the spray to discharge in an axial direction with the steam flow. The resulting finally atomized hollow cone water spray emerges and fully develops before mixing with the steam. FIGURE 2 Water TCV Desuperheated steam Desuperheated steam 3
4 APPLICATIONS The SPID Desuperheater is used upstream of process steam shell and tube heat exchangers. Often process steam equipment experiences chronic tube fouling due to product break out from high superheat temperatures resulting in decreased heat exchanger efficiencies and costly lost production during down time clean outs. Here the final product can benefit from controlling process steam temperatures to within 6 C of saturation and within ± 1% of controller range. Powerhouse applications would include steam turbine gland sealing, air ejectors, Nox steam for gas turbines and house steam needs. Other applications include steam for drum dryers, tire molds, vulcanizing equipment and cooking kettles. In general, any steam desuperheating in small pipe lines. WATER SPRAY PORTS The SPID Desuperheater may be equipped with a variety of water spray ports. The uniform steam nozzle insert accepts spray ports with a wide range of C v (K v ) values. Standard configurations are with either 1 to 8 equally sized spray ports are available with a rangeability of 1 : 40 depending on application. This feature enables the SPID Desuperheater to be customized to specific system requirements. Consult Yarway or your local representatives for details. TABLE 1 - SPID STANDARD CAPACITY RANGE Body Size Ports B NPS 1½ C v = DN 40 K v = C NPS 2 C v = DN 50 K v = D NPS 3 C v = DN 80 K v = E NPS 4 C v = DN 100 K v = H W G W FIGURE 3 H 1 G ST H 2 G ST + G W SIZING FORMULA Every desuperheating station is a mixing point where there is a heat and mass balance. The universal formula is: G W = G ST ( H 1 -H 2 ) : ( H 2 -H W ) In which: G W = G ST = H 1 = H 2 = H W = Injection water mass Inlet steam mass Enthalpy of the inlet steam Enthalpy of the outlet steam Enthalpy of the injection water This formula enables calculation of the quantity of water required to lower the inlet steam temperature to the set - point temperature of the outlet steam. 4
5 IMPORTANT SYSTEM PARAMETERS Apart from the spray quality of the atomizer (primary atomization) there are other system parameters which influence the desuperheater stations performance. These are: Water to steam ratio This ratio is determined by dividing G W by G ST = 6 : 1. Above this ratio, proper evaporation of the injection water cannot always be guaranteed. In case of doubt, consult Yarway. Distance to sensor The distance from the SPID Desuperheater to the temperature sensor should be 12 to 15 meters, although the distance specific to the application is advised by Yarway at the enquiry stage. Longer distances will ensure that full evaporation of the water will take place at lower velocities. Required straight pipe run The minimum pipe run, required downstream, varies with each individual application and is specified by Yarway at the enquiry stage. This straight run is needed to prevent erosion due to impingement of water droplets against pipe walls, valves and fittings. Upstream straight run is normally 2 x D and the downstream straight run 20 x D, as a minimum. ORDERING/SIZING DATA Steam desuperheaters are selected specifically against application data. For optimal sizing, the following comprehensive data should always be supplied. Steam data Inlet pressure bar Inlet temperature C Outlet temperature C set point Steam flow max. t / hr Steam flow normal t / hr Steam flow min. t / hr Water data Water pressure bar Water temperature C General Pipe size Pipe schedule mm Application Yarway does recommend a strainer with a mesh size of approx. 100 µ in the water supply line to protect the SPID Desuperheater from clogging. For applications outside these limitations, consult Yarway or your local representative. TABLE 2 - MODEL NUMBER SPECIFICATION Sample model number 8 A 600 W080 C F 8 Designation for the SPID which is the Series A ANSI - American National Standards Institute D DIN - German Industrial Standards J JIS - Japanese Industrial Standards B BS - British Standard Body rating selections F raised face flanged wafer ends. If flanged, then = F 000 W butt weld ends If butt weld, then: ANSI: incl. schedule 80 = W080 DIN - JIS - BS: incl. schedule thickness 6.02 = W602 Body size letter selections Available C v (K v ) selections Water flange rating selections should be equal to or greater than the body rating F Raised face flange water connection 5
6 TABLE 3 - STANDARD MATERIALS Item Name Material Body ASTM SA 182 F11 2 Insert AISI Nipple ASTM SA 335 P11 4 Flange ASTM SA 182 F11 CERTIFICATION 3 3 B SPID Desuperheaters are approved by authorized authorities to comply with the requirements of ASME B All data subject to changes. NOTE Dimensions may be subject to change without prior notification. Yarway will provide a certified dimensional drawing upon request A RF A BW FIGURE 4 TABLE 4 - DIMENSIONS - WEIGHT Weight A B Water connections Size kg lbs Body Steam connections mm inch mm inch Size Rating 1½ ASME class RF (wafer) / ⅞ ½ ASME class 150/300/ /300/600 BW sched ⅜ /32 flanged BW sched ⅜ /16 RF ASME class RF (wafer) / ⅞ ½ ASME class 150/300/ /300/600 BW sched / /32 flanged BW sched / /16 RF ASME class RF (wafer) / /16 ½ ASME class 150/300/ /300/600 BW sched / /16 flanged BW sched / ⅞ RF ASME class RF (wafer) 60 2⅜ /32 1 ASME class 150/300/ /300/600 BW sched / /16 flanged BW sched / /16 RF 6
7 TABLE 5 - STANDARD MATERIALS Item Name Material Body Insert Nipple Flange CERTIFICATION 3 3 B SPID Desuperheaters are approved by authorized authorities to comply with the requirements of e.g. EN All data subject to changes. NOTE Dimensions may be subject to change without prior notification. Yarway will provide a certified dimensional drawing upon request FIGURE 5 A RF A BW TABLE 6 - DIMENSIONS - WEIGHT Water connections Size Weight kg Body Steam connections A mm B mm Size Rating PN 16/40/64/100 RF (wafer) DN 15 PN 16/40/64/100 BW sched flanged BW sched RF PN 16/40/64/100 RF (wafer) DN 15 PN 16/40/64/100 BW sched flanged BW sched RF PN 16/40/64/100 RF (wafer) DN 15 PN 16/40/64/100 BW sched flanged BW sched RF PN 16/40/64/100 RF (wafer) DN 25 PN 16/40/64/100 BW sched flanged BW sched RF 7
8 8
YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and
More informationYarway Narvik Ven-Temp Desuperheater Model 25
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and
More informationYARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER
Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp and paper industry and
More informationStandard Duty Que - Temp Desuperheater Model: 33 / 43
Model: 33 / 43 Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp
More informationHeavy Duty Que - Temp Desuperheater Model: 13 / 23
Narvik covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry and
More informationStandard Duty SLN - Temp Desuperheater Model: 50 / 60
Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp & paper industry
More informationYARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp and paper industry and
More informationLESLIE DESUPERHEATERS SIZES 1/2" 16" ANSI Class 150 to 2500
LINER LESLIE DESUPERHETERS SIZES 1/" 16" NSI Class 150 to 500 Fabricated and forged constructions High quality stuffing box Variable nozzle type Wide range of Cv (Kv) capacities available Special nozzle
More informationYARWAY NARVIK MODEL 60/70 STANDARD DUTY SLN-TEMP DESUPERHEATER
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp and paper industry and
More informationNARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64
NARVIK-YARWAY Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp &
More informationYarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide of models, sizes and materials to satisfy the specifications of the power, pulp and paper industries along with
More informationStandard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34
Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry
More informationStandard Duty A.T.-Temp Desuperheater for cryogenic processes
Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry
More informationYarway Narvik Model 37 and 47 Cryogenic injector
Cryogenic injector for LNG applications Features Fabricated construction High quality stuffing box with PTFE Chevron rings Variable nozzle type Wide range of K v (C v ) available Special nozzle combinations
More informationTempLowHT Steam Desuperheater Model: 59/69/79
NARVIK-YARWAY The TempLowHT utilizes the fundamental design concepts of the standard Templow, designed for temperatures up to 1150 F (621 C). The TempLowHT is designed to eliminate sliding trim parts in
More informationFLOW TEK VALVES & CONTROL S INC
FLOW TEK VALVES & CONTROL S INC e-mail:- info@flowagevalves.com PLOT NO-172,173, ROAD NO-4, KATHWADA, G.I.D.C. AHMEDABAD. PHONE NO:- 079-22900219,22900220, MOBILE:-09824539702, 9824080899. an ISO 9001
More informationVAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004
MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004 MNSD V MULTIPLE NOZZLE SPRAY DESUPERHEATER Multiple Nozzle Spray Desuperheater Offers High Temperature Capabilities and Low Class V Leakage
More informationVELOCITY CONTROL TECHNOLOGY DESUPERHEATERS
VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS D Series 1 KOSO offers an adequate variety of desuperheating solutions. Most importantly, KOSO has the knowhow to help select the right solution using software
More informationMNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001
MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001 MNSD V MULTIPLE NOZZLE SPRAY DESUPERHEATER Multiple Nozzle Spray Desuperheater Offers High Temperature Capabilities and Low Class
More informationSEMPELL TURBINE BYPASS VALVE MODEL 115 CHP
A range of high pressure turbine bypass valves that provide greater reliability under extreme conditions. FEATURES Pressure reduction by multi-stage controlled expansion Atomizing steam desuperheater,
More informationDirect Contact Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMNSD-V & MNSD-U. Multiple Nozzle Spray Desuperheater
MNSD-V & MNSD-U Multiple Nozzle Spray Desuperheater Copes-Vulcan has been providing control valves and desuperheaters for the power, process and nuclear industries since 1903. SPX provides a wide range
More informationSAMSON 3281 & Steam Converting Valves SMART IN FLOW CONTROL
SAMSON 3281 & 3286 Steam Converting Valves SMART IN FLOW CONTROL FEATURES AND BENEFITS Integrated Accessory Attachment Eliminates external tubing Protects mechanical feedback linkage Entire actuator top
More informationDirect Contact Desuperheaters
Control Description Spirax Sarco direct contact desuperheaters reduce the temperature of superheated steam to produce steam temperatures approaching saturation temperature to cool the superheated steam,
More information10000 SERIES. Steam Desuperheater With Spray Nozzles
10000 SERIES Steam Desuperheater With Spray Nozzles Engineering Data General The desuperheaters Series 10000 provide the right technical solution to reduce steam temperature when large spray water flows
More informationFisher DFA Variable Geometry Desuperheater
DFA Desuperheater Product Bulletin Fisher DFA Variable Geometry Desuperheater The Fisher DFA (Desuperheater with Flexible Architecture) can be used in many applications to efficiently control the spraywater
More informationFisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters
Instruction Manual DMA Desuperheater Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters Contents Introduction... 2 Scope of Manual... 2 Description... 2 Specifications... 2 Principle
More informationDatasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents
Datasheet for MATRE Foam Inductors 1 Contents 2 General product description... 3 3 General installation guide... 3 4 Product dimensions and performance... 3 4.1 Standard bronze housing design - threaded...4
More informationSERIES DESUPERHEATERS
3-4000 SERIES DESUPERHEATERS 2 3-4000 SERIES DESUPERHEATERS PARCOL 3-4000 series desuperheaters are used to reduce the steam temperature by directly water injection inside the superheated steam flow. The
More informationYARWAY THROTTLING VALVES HY-DROP MODEL 5817/ 5827
Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation. 5817- ASME class 1700 5827- ASME class 2700 FEATURES GENERAL APPLICATION The Hy-Drop throttling
More informationDESUPERHEATER (SERIES 800)
INTRODUCTION DESUPERHEATER (SERIES 800) The evolutionary series 800 Desuperheater i.e. Varitrol variable spray nozzles unit can be used in many applications to efficiently reduce the superheated steam
More informationMA-III & MA-IIIU MECHANICAL ATOMIZING DESUPERHEATER
MA-III & MA-IIIU MECHANICAL ATOMIZING DESUPERHEATER Copes-Vulcan has been providing control valves and desuperheaters for the power and process industries since 1903 and been supplying nuclear valves for
More informationSeries DK. Type DKV. Desuperheaters to control the Temperature of Superheated Steam (or Gas)
Series DK Type DKV Desuperheaters to control the Temperature of Superheated Steam (or Gas) Introduction Desuperheating (cooling) the steam can simply be achieved by inject water into the steam flow. When
More informationHigh End Technology. Tight Shutoff. Reliability. Expertise you can trust. General Products
High End Technology Tight Shutoff Reliability Expertise you can trust General Products 210 Who are we? 248 MASCOT is a culmination of over one hundred years experience in the process control valve industry
More informationSeries DK Type DKV and DKM
Series DK Type DKV and DKM Desuperheaters to Control The Temperature of Superheated Steam (or Gas) 5/16 Version 1 Introduction Figure 1: From Left DKV, DKM Desuperheating (cooling) the steam can simply
More informationYarway Hy-Drop Throttling valve
YARWAY Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation Features Dual range throttling - primary range plus a super capacity blast range. Rapid energy
More informationDesuperheaters Fixed Nozzle, Minicooler Design and Variable Nozzle
Desuperheaters Fixed Nozzle, Minicooler Design and Variable Nozzle Dynamic Temperature Control for your Entire System Energy Conservation Environment Process Efficiency www.forbesmarshall.com Forbes Marshall
More informationControls the destructive forces inherent in high pressure drop service through rapid energy dissipation.
Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation. Features General application The throttling valve is designed for continuous blowdown, but also
More informationControls the destructive forces inherent in high pressure drop service through rapid energy dissipation.
Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation. General Description Valves used for throttling services have always been subject to rapid deterioration
More informationFisher DFA Variable Geometry Desuperheater
Instruction Manual DFA Desuperheater Fisher DFA Variable Geometry Desuperheater Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 3 Principle of Operation... 3 Installation...
More informationInjection Desuperheater
Injection Desuperheater Purpose & Advantages The ARTES desuperheater is a control valve with which the temperature of vapour can be regulated by injecting cooling water. The ARTES desuperheater is frequently
More informationSTEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE
STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE Benefits Savings of up to US$ 200.000 per year in maintenance costs Production gains due to superior stability of the temperature control Operational
More informationPRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES
PRESSURE REDUCING AND DESUPERHEATING STATIONS 1-5700 SERIES - 2 - I.P. to condenser bypass valve 1-5765 - Inlet: DN 30 ANSI 900 BW - Outlet: DN 60 ANSI 300 BW - Port : 443 mm Body material: SA182 F91 /
More informationCROSBY STYLE JB PRESSURE RELIEF VALVE
A large orifice pressure relief valve engineered to provide high quality, dependable overpressure protection for air, gas, vapor and steam applications FEATURES Ten size product range is the broadest available.
More informationAPPLICATIONS IN PALM OIL MILL - CONTROL VALVE - DESUPERHEATER -PRDS -FLOWMETER -GAUGES
ENGINEERING (M) SDN BHD 18, JALAN 18, TAMAN SRI KLUANG, 86000 KLUANG, JOHOR, MALAYSIA. TEL : +607-777 1055 FAX : +607-777 1066 E : sales@leesonmech.com W : www.leesonmech.com APPLICATIONS IN PALM OIL MILL
More informationYarway TempLow Steam Desuperheater Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Principles of operation The Yarway TempLow Desuperheater (also model 91 and 93) responds to pneumatic or electric signals generated
More information5. Combustion of liquid fuels. 5.1 Atomization of fuel
5. Combustion of liquid fuels 5.1 Atomization of fuel iquid fuels such as gasoline, diesel, fuel oil light, fuel oil heavy or kerosene have to be atomized and well mixed with the combustion air before
More informationYARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000
Direct contact and metal-to-metal seating make this Y-pattern globe stop valve ideal for most shut-off applications. FEATURES All valves feature integral Stellite hardfacing on both body and disc seating
More informationEXTRACTION CHECK VALVES TYPE C09.6
Application Extraction check valves are valves used to to prevent the back flow of the service fluid in extraction and bleed lines of steam turbines. Each extraction check valve is designed exactly for
More informationORIFICE PLATE flow meters
ORIFICE PLATE flow meters 1 Differential pressure and pressure loss When a throttle element is interposed in a closed passage of fluid in piping, a difference is produced between the pressure upstream
More informationDirect Steam Converting Valves Model DSCV-SA
Direct Steam Converting Valves Model DSCV-SA Introduction The Copes Vulcan large capacity combined pressure reducing and desuperheating valve, which is known as the DSCV, is of angle style construction
More informationKTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE
A rugged, long-life V-port control ball valve with excellent flow characteristics for various fluids including slurries and fibers FEATURES GENERAL APPLICATION Steam, liquids, gas or critical services
More informationSERIES MULTIPLE NOZZLE DESUPERHEATERS
1-4440 SERIES MULTIPLE NOZZLE DESUPERHEATERS 1-4442 SERIES SPRAYSAT DESUPERHEATERS MAIN FEATURES BODY sizes: water: 1" to 3"; steam: 3", 4" or 6" depending on the selected Cv. connections: ANSI, UNI and
More informationFull cone nozzles.
nozzles Absorption Chemical process engineering Chlorine precipitation Cleaning Cooling esuperheating ust control Fire protection Foam control as treatment ing onto mats in air washers ing over packings
More informationSeries Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features
Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features General application Designed for ASME boiler and pressure vessel code, section I applications
More informationHigh Pressure Turbine Bypass Valve HBSE
High Pressure Turbine Bypass Valve HBSE 2 HBSE from Sulzer Valves delivers pressure reduction, temperature control and fast response in a compact, high pressure steam conditioning valve. The Rugged, Compact
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationPurpose & Advantages. The ARTES desuperheater can be actuated by means of electric, pneumatic or hydraulic drives.
V R Purpose & Advantages The ARTES desuperheater is a regulating valve with which the temperature of vapour can be regulated by injecting cooling water. The ARTES desuperheater is frequently used in steam
More informationYarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions
Before installation these instructions must be fully read and understood Model 33 / 43 Installation of the Que - Temp Desuperheater Model 13 / 23 Before installation, check the Que - Temp Desuperheater
More informationSTEAM CONDITIONING VALVES TECHNICAL BULLETIN HORA POWER TECHNOLOGY
STEAM CONDITIONING VALVES TECHNICAL BULLETIN HOLTER REGELARMATUREN GMBH & CO. KG POWER TECHNOLOGY OUR ASPIRATION AIMING FOR THE TOP For 50 years our customers have relied on HORA as a competent partner
More informationDVG/AF Variable Geometry Desuperheater
Instruction Manual D101616X012 DVG/AF Desuperheater DVG/AF Variable Geometry Desuperheater Contents Introduction............................... 1 Scope of Manual.......................... 1 Description...............................
More informationELECTRIC POWER RESEARCH INSITUTE (EPRI) 2011 CONDENSER TECHNOLOGY CONFERENCE AUGUST 3-4, 2011, CHICAGO, ILLINOIS
ELECTRIC POWER RESEARCH INSITUTE (EPRI) 2011 CONDENSER TECHNOLOGY CONFERENCE AUGUST 3-4, 2011, CHICAGO, ILLINOIS IMPORTANCE OF TEMPERATURE OF BYPASS STEAM ADMITTED INTO A STEAM SURFACE CONDENSER IN A COMBINED
More informationVB VALVES & AUTOMATION
Introduction to Valve What are Valves? Valves are mechanical device that controls the flow and pressure within a system or process. They are essential components of a piping system that conveys liquids,
More informationHoneywell EN REV. 2 09/2014 Page 1 of 10 Specification
Series 9110 Single/Double Seated Globe Valves for ANSI 150-600 DIN/BS 4504 PN10-PN40 Honeywell 70-16-10-05 EN REV. 2 09/2014 Page 1 of 10 Specification Series 9110 Single/Double Seated Globe Valves for
More informationHollow cone nozzles.
Absorption Chemical process engineering Cooling isinfection esuperheating ust control Fire protection Foam destruction Gas treatment umidification of air, goods, or textiles Oil spraying Protection of
More informationKunkle Bailey 756 safety relief valve
The 756 safety valve combines a top piston guided valve and an unobstructed seat bore with a full lift capability, giving maximum discharge capacity Features Design incorporates an adjustable blowdown
More informationDP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationWE CONTROL WHAT MATTERS
WE CONTROL WHAT MATTERS Valve control solutions for gas processing plants Industrial Control Valves and Regulators Ramén Valves Control Made in Sweden Industries Ramén Ball Sector Valve Type KS, designed
More informationPressure Reducing and Desuperheating Valves
Pressure Reducing and Desuperheating Valves Solutions for Steam Conditioning Applications Energy Conservation Environment Process Efficiency www.forbesmarshall.com Features Compact design Pressure reduction
More informationInstallation and Maintenance Instructions
Before installation these instructions must be fully read and understood Particular care should be taken when removing the A.T.-Temp Desuperheater from its packing and your special attention is required
More informationHANCOCK GATE, GLOBE AND CHECK VALVES CAST STEEL
ANCOCK GATE, GOBE AND CECK VAVES CAST STEE A range of ASME Class 150, 300 and 600 bolted bonnet cast steel valves, with metal-to-metal seating in flanged or butt weld ends FEATURES Gate valves Internal
More informationDesign V150S Slurry Vee-Ball Control Valve
Product Bulletin Design V150S Slurry Vee-Ball Control Valve Slurry Vee-Ball Valve The Design V150S Slurry Vee-Ball valve shown in figure 1 mates with CL150 raised face flanges. Rugged construction, highly
More informationSeries TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection
Series TD Type TDL Type TDM Automatic Recirculation Valve for pump protection Series TD The SCHROEDAHL Automatic Recirculation Valve is used for the pump protection of centrifugal pumps Preamble SCHROEDAHL
More informationIBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationStandard Duty A.T.-Temp Desuperheater for cryogenic processes Installation and Maintenance Instructions
Unpacking The A.T. - Temp Cryogenic desuperheater is packed with the greatest of care in wooden boxes or cartons for protection during handling and transit to site. After hydrostatic testing, the unit
More informationSeries TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection
Series TD Type TDL Type TDM Automatic Recirculation Valve for pump protection Series TD The SCHROEDAHL Automatic Recirculation Valve is used as a pump protection system for centrifugal pumps Preamble SCHROEDAHL
More informationPRODUCT PORTFOLIO VALVES
BORSIG SERVICE GMBH PRODUCT PORTFOLIO VALVES www.borsig.de Borsig service GmbH ABOUT BORSIG VALVES BORSIG offers comprehensive products and service solutions for power generation, the oil and gas industries
More informationSempell High Pressure Stop Valves Model VA500 (ASME)
7 Sempell High Pressure Stop Valves Designed for the isolation and control of high temperature and high pressure systems, this multipurpose globe valve can be used in a wide variety of applications. Features
More informationCompac-Noz Valves High Performance Non-Slam Check Valves
Compac-Noz Valves High Performance Non-Slam Check Valves Compac-Noz Non-Slam Check Valves Scope of Line and Features Sizes 12" - 60" ASME B16.34 & API 6D, pressure classes 150-4500 API 6A pressure classes
More informationDAM. Engineering GREAT Solutions. Steam Desuperheater
DAM Engineering GREA Solutions Steam Desuperheater DAM: Steam Desuperheater DAM: Steam Desuperheater Desuperheating is used to improve the thermal efficiency of heat transfer processes by lowering the
More informationLecture 27: Principles of Burner Design
Lecture 27: Principles of Burner Design Contents: How does combustion occur? What is a burner? Mixing of air and gaseous fuel Characteristic features of jet Behavior of free (unconfined) and confined jet
More informationControl Valves for Severe Service Applications
Control Valves for Severe Service Applications DFT HI-100 Control Valve Features an In-Line Straight-Thru Venturi Flow Design DFT designs products using the latest CAD, FEA, and CFD design technology software
More informationInstallation and Maintenance Instructions
Before installation these instructions must be fully read and understood Particular care should be taken when removing the A.T.-Temp Desuperheater from its packing and your special attention is required
More informationHIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES
HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES 1-4470 SERIES - 2 - DESCRIPTION HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES 1-4470 SERIES Parcol 1-4470 High Temperature High Pressure Control Valves represent
More informationDiaphragm Valve, Metal
Diaphragm Valve, Metal Construction The GEMÜ pneumatically operated 2/2-way diaphragm valve has a low maintenance actuator. Normally Closed, Normally Open and Double Acting control functions are available.
More informationBULLETIN 1163 MARCH 2002 TURBINE BYPASS SYSTEMS
BULLETIN 1163 MARCH 2002 TURBINE BYPASS SYSTEMS TURBINE BYPASS SYSTEMS Turbine Bypass Systems Copes-Vulcan has been supplying steam conditioning equipment for turbine bypass applications since the 1950s.
More informationA type Ejectors (in line) Dimensions and weights
A type Ejectors (in line) Dimensions and weights Our A type ejectors have the best efficiency and are therefore our most commonly sold type. The motive water is coming from the side and suction is created
More informationSempell High Pressure Stop Valves Model VA510 (DIN)
Designed for highest pressure and temperature applications using high alloy or stainless steels. Features T-pattern globe type Body made of forged steel Wear resistant stellite body seat Conical seat with
More informationHollow Cone Spray Nozzles Series
Hollow Cone Spray Nozzles Series TANK WASHING HOLLOW CONE APPLICATION Absorption Chemical process engineering Cooling Disinfection Desuperheating Dust control Fire protection Foam destruction Gas treatment
More informationSeries Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.
7 YARWAY Hancock T-Pattern Globe valves Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications Features Heavy integral stellite hardfacing on
More informationOPTIMIZING QUILL AND INJECTOR PERFORMANCE IN REFINERY OPERATIONS
Experts in Spray Technology WHITE PAPER: OPTIMIZING QUILL AND INJECTOR PERFORMANCE IN REFINERY OPERATIONS There are dozens of operations in refineries where quills and injectors are used. Before we discuss
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationHANCOCK 600 GATE, GLOBE AND CHECK VALVES CAST STEEL
ANCOCK 600 GATE, GOBE AND CECK VAVES CAST STEE A range of ASME Class 150, 300 and 600 bolted bonnet cast steel valves, with metal-to-metal seating in flanged or butt weld ends FEATURES Gate valves Internal
More informationDRAG VLN Turbine Bypass Valve for Hot Reheat Bypass Applications
DRAG VLN Turbine Bypass Valve for Hot Reheat Bypass Applications VLN delivers superior pressure reduction and temperature control in a compact, high capacity steam conditioning control valve. 2 n Proven
More informationHollow cone. nozzles
Absorption Chemical process engineering Cooling isinfection esuperheating ust control Fire protection Foam destruction Gas treatment umidification of air umidification of goods umidification of textiles
More informationTRUNNION MOUNTED METAL SEATED BALL VALVES
TRUNNION MOUNTED METAL SEATED BALL VALVES HIGH PERFORMANCE BALL VALVES FOR SEVERE SERVICES PROCESS VALVES STANDARD FEATURES FOR SIDE ENTRY & BOTTOM ENTRY DESIGN 1. Trunnion Mounted The ball is trunnion
More informationFor Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others
Nozzles Control Analysis Fabrication FloMax Air Atomizing Nozzles Unique Atomization Process Provides Unmatched Efficiency in Gas Conditioning Operations For Applications Demanding Precision and Efficiency,
More informationRight Angle Nozzle Assembly
Swirl- Air atomizing nozzle Features: Large internal passages with no vanes or cores assure unrestricted flow... Little chance for clogging No external struts or supports to interfere with spray pattern
More informationFisher V150S Slurry Vee-Ball Control Valve
Slurry Vee-Ball Valve Product Bulletin Fisherr V150S Slurry Vee-Ball Control Valve The Fisher V150S Slurry Vee-Ball valve mates with CL150 raised face flanges. Rugged construction, highly wear-resistant