application guide axial condensing units

Size: px
Start display at page:

Download "application guide axial condensing units"

Transcription

1 application guide axial condensing units 17 English/

2 Congratulations you have made a wise choice and we feel sure that it will meet your expectations WARNING: Read this manual before installation, reparation o maintenance works. CONTENTS PAGE RANGE PRODUCT GENERAL DESCRIPTION PHYSICAL DATA ELECTRICAL DATA FAN PERFORMANCES SOUND PRESSURE / SOUND POWER LEVEL CAPACITY TABLES UNIT DIMENSIONS Lennox have been providing environmental solutions since 1895, our range of condensing units continues to meet the standards that have made LENNOX a household name. Flexible design solutions to meet YOUR needs and uncompromising attention to detail. Engineered to last, simple to maintain and Quality that comes as standard. Information on local contacts at All the technical and technological information contained in this manual, including any drawing and technical descriptions provided by us, remain the property of Lennox and must not be utilised (except in the operation of this product), reproduced, issued to or made available to third parties without the prior written agreement of Lennox.

3 RANGE PRODUCT COOLING ONLY CONDENSING UNITS HEAT PUMP CONDENSING UNITS V/Ph/50Hz V/Ph/50Hz NOMINAL CAPACITY kw COOLING NOMINAL CAPACITY kw NOMINAL CONSUMPTION kw COOLING V+N/1Ph V+N/1Ph V+N/1Ph E 230V+N/1Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph E 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph D 400V+N/3Ph temperature(dew point)= +7ºC/ temperature =+3 NOMINAL CONSUMPTION kw COOLING HEATING COOLING HEATING V+N/1Ph V+N/1Ph V+N/1Ph V+N/1Ph V+N/3Ph V+N/3Ph V+N/3Ph V+N/3Ph V+N/3Ph E VFC 400V+N/3Ph E VFC 400V+N/3Ph E VFC 400V+N/3Ph E VFC 400V+N/3Ph D VFC 400V+N/3Ph D VFC 400V+N/3Ph D VFC 400V+N/3Ph D VFC 400V+N/3Ph D C50 400V+N/3Ph D C50 400V+N/3Ph D C50 400V+N/3Ph temperature(dew point)= +7ºC/ temperature =+3 Condensing temperature=4/ temperature 8ºC DB/7ºCWB 2

4 GENERAL DESCRIPTION - The air conditioner - units on version cooling only and heat pump, are units condensed by air, designed for small shopping center and housing. hey are supplied to match with other type of indoor unit that the customer needs. They are designed for installation outdoors, with a wide range of options, completed-factory assembled are also available. CABINET The unit chassis is made of galvanized steel with epoxy painted finished, able to work with outdoors under the worst conditions. The unit is completed with handles, which assist easy installation. Its compact dimensions and features allow the unit to be positioned in almost any location. COMPRESSOR All units are provided with scroll compressor, cooling by a suction gas with thermic protection inside the engine, so no other additional protection is required. It is mounted on antivibration devices both external and internal. The 400V-III units are supplied with a three phase detector which avoids the unit starts, unless the phase connections are right. In heat pump units, the compressors are provided with a crankcase heater to heat the oil in the compressor so that a suitable lubrication can take place; this is an option for cooling only units. FANS The units are supplied with one or two axial motor fans, with exceptional features in noise level and flow. -knhk HEAT EXCHANGERS Made-up with copper pipes and aluminium wings, designed to get a high heating transfer. Their dimensions and design of the circuits have been specially worked to obtain the maximum performance of the exchanger increasing the power of the unit and reducing the consumption. COOLING CIRCUIT Made of welded dehydrated copper pipe with service port on the suction and liquid lines. It includes coupling valves to make easier the refrigerant connection. Heat pump units are equipped as well with unidirectional and four way reversing valves. SWITCHBOARD The heat pump unit includes a printed board with a defrosting timer, for safety device. The condensing units and units, of the air to air type, designed for small and medium shopping center and housing. They are supplied to match with other type of indoor unit that the customer needs. They are designed for installation outdoors, with a wide range of options, completed-factory assembled are also available. CABINET Made of galvanized steel sheeting with epoxy painted finish, weather proofed with high resistant to corrosion. The units are provided with metal profiles, capable of withstanding the unit and able as well of installing the unit mounted on the floor. COMPRESSOR All units are provided with hermetically sealed compressors, scroll type, cooled by exhaust gas, with internal thermal insulation inside the engine, so no other additional protection is required. The compressor is fitted on vibration mountings both inside and outside. The compressors have a screwed connection into the pipe thus they can be more easily to assembled. In heat pump units the compressors are provided, as standard, with a crankcase heater (optional for cooling only units), to assist evaporation of the coolant retained by the oil in the compressor so that a suitable lubrication can take place. FANS The units are supplied with one and two fans axial type, of direct coupling and motor with external rotor and excellent features on sound levels. HEAT EXCHANGERS Made of copper tubing with aluminum corrugated swirl fins, they are designed and specially dimensioned to obtain the maximum output so as to prevent ice forming in the outer heater, extending the operating cycles to a maximum obtaining maximum output and exchange on reducing the frequency of defrosting. COOLING CIRCUIT Made of welded dehumidifying copper tube with plugged valves in the suction and liquid lines. The units are supplied with high and low pressure switches, with automatic reset. Silencer fitted on the compressor discharge, and expansion system through a reducing valves. Heat pump units () are equipped with dehumidifying filter to avoid liquid getting on the compressor, four way valve for reversing cycle, and one way valves. SWITCHBOARD Designed according to EN normative. With protective fuses for compressors and fans, except for the ones adjustable and variable activating motor which are supplied with an external thermic relay. The units have a built printed circuit board which controls the unit. 3

5 PHYSICAL DATA cooling only units Nominal cooling capacity (*) E 12E 16E 18E 22E kw COMPRESSOR Nr/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll Nr 1 CAPACITY STEPS % FAN Air flow m 3 /h WEIGHT Kg DIMENSIONS REFRIGERANT CONNECTION Height (H) mm Width (W) mm Depth (D) mm Liquid pipe 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" Gas pipe 1/2" 5/8" 5/8" 3/4" 3/4" 3/4" 7/8" 7/8" (*) temperature(dew point)= +7ºC/ temperature =+3 (24E) (24E 43E) (48D 86D) (112D 152D) Nominal cooling capacity (*) COMPRESSOR CAPACITY STEPS 24E 32E 38E 43E 48D 64D 76D 86D 112D 128D 152D kw Nr/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll 2/Scroll 2/Scroll 2/Scroll 2/Scroll 3/Scroll 3/Scroll 3/Scroll Nr 1 2 % FAN Air flow m 3 /h WEIGHT Kg DIMENSIONS REFRIGERANT CONNECTION Height (H) mm Width (W) mm Depth (D) mm Liquid pipe 5/8" 5/8" 3/4" 7/8" 2x5/8" 2x5/8" 2x3/4" 2x7/8" 2x3/4" 2x7/8" 2x7/8" Gas pipe 1-1/8" 1-1/8" 1-3/8" 1-5/8" 2x1-1/8" 2x1-1/8" 2x1-3/8" 2x1-5/8" 2x1-3/8" 2x1-5/8" 2x1-5/8" (*) temperature(dew point)= +7ºC/ temperature =+3 4

6 PHYSICAL DATA HEAT PUMP units Nominal cooling capacity (*) kw Nominal heating capacity (**) kw COMPRESSOR Nr/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll Nr 1 CAPACITY STEPS % FAN Air flow m 3 /h WEIGTH Kg DIMENSIONS REFRIGERANT CONNECTION 080 Height (H) mm Width (W) mm Depth (D) mm Liquid pipe 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" Gas pipe 1/2" 5/8" 5/8" 3/4" 3/4" 3/4" 7/8" 7/8" (*) temperature(dew point)= +7ºC/ temperature =+3 (**) Condensing temperature=4/ temperature 8ºC DB/7ºCWB (24E) (24E 43E) (48D 86D) (112D 152D) 24E 32E 38E 43E 48D 64D 76D 86D 100D 128D 152D Nominal cooling capacity (*) kw Nominal heating capacity (**) kw COMPRESSOR Nr/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll 2/Scroll 2/Scroll 2/Scroll 2/Scroll 2/Scroll 3/Scroll 3/Scroll CAPACITY STEPS Nr 1 2 % FAN Air flow m 3 /h WEIGHT Kg Height (H) mm DIMENSIONS Width (W) mm Depth (D) mm REFRIGERANT CONNECTION (***) Liquid pipe Gas pipe C1 C2 C1 C2 5/8" 5/8" 3/4" 7/8" 2x5/8" 2x5/8" 2x3/4" 2x7/8" 2x3/4" 1-1/8" 1-1/8" 1-3/8" 1-5/8" 2x1-1/8" 2x1-1/8" 2x1-3/8" 2x1-5/8" 2x1-3/8" 7/8" 3/4" 1-5/8" 1-3/8" 2x7/8" 2x1-5/8" (*) temperature(dew point)= +7ºC/ temperature =+3 (**) Condensing temperature=4/ temperature 8ºC DB/7ºCWB 5

7 ELECTRICAL DATA Voltage V/f (50Hz) V+N/1Ph 10E 12E 16E 400V+N/3Ph 18E Nominal absorbed power kw Maximum current (A) 230V-1Ph E 4000V-3Ph Start up current (A) 230V-1Ph V-3Ph (24E) (24E 43E) (48D 86D) (112D 152D) 24E 32E 38E 43E 48D 64D Voltage V/f (50Hz) 400V+N/3Ph Nominal absorbed power (Cooling) 76D 86D 112D 128D 152D kw Maximum current (A) 4000V-3Ph Start up current (A) 4000V-3Ph

8 ELECTRICAL DATA Voltage V/f (50Hz) Nominal absorbed power (Cooling) Nominal absorbed power (Heating) Maximum current (A) Start up current (A) V+N/1Ph V+N/3Ph kw kw V-1Ph V-3Ph V-1Ph V-3Ph (24E) (24E 43E) (48D 86D) (112D 152D) 24E 32E 38E 43E 48D 64D 76D 86D 112D 128D 152D Voltage V/f (50Hz) 400V+N/3Ph Nominal absorbed power (Cooling) Nominal absorbed power (Heating) kw kw Maximum current (A) 4000V-3Ph Start up current (A) 4000V-3Ph OPTION FP1/FP2 KNCK/ 100D FP1/FP2 KNCK/ 128D FP1/FP2 KNCK/ 152D FP1/FP2 Voltage V/f (50Hz) 400V+N/3Ph 112D FP1/FP2 128D FP1/FP2 152D FP1/FP2 Maximum absorbed power kw 44.6/ / / / / /71.2 Maximum current (A) 4000V-3Ph 69.2/ / / / / /

9 FAN PERFORMANCES E E E E E 080 Fan mumber Airflow m3/h (24E) (24E 43E) (48D 86D) (112D 152D) 24E 32E 38E 43E 48D 64D 76D 86D 112D 128D 152D Fan mumber Airflow m3/h OPTION FP1/FP2 / 112D FP1/FP2 / 128D FP1/FP2 / 152D FP1/FP2 Fan mumber 2 Airflow m3/h 29000/

10 SOUND PRESSURE/SOUND POWER LEVEL Specctrum per octave band db(a) 125 Hz 250 Hz 500 Hz 1000Hz 2000 Hz 4000 Hz 8000 Hz Sound Power Lw db(a) Sound pressure at 10m Lp db(a) /HK 018 /HK 024 /HK 30 10E E E E E E 24E 32E 32E 38E 38E 43E 43E 48D 48D 64D 64D 76D 76D 86D 86D (1) (2) (1) (2) (1) (2) (1) 69,4 67,7 66,9 65,8 64,0 62,4 52,0 71,1 43,1 (2) 69,4 67,7 66,8 65,7 63,6 60,6 52,0 70,7 42,7 (1) 72,4 70,7 70,1 69,3 66,9 65,0 55,0 74,2 46,2 (2) 72,4 70,7 69,9 68,9 66,6 63,8 55,0 73,8 45,8 (1) 72,4 70,7 70,2 69,9 67,5 64,5 55,0 74,5 46,5 (2) 72,4 70,7 70,0 69,2 66,8 63,2 55,0 73,9 45,9 (1) 72,4 70,7 70,2 69,8 68,4 65,2 58,0 74,9 46,9 (2) 72,4 70,7 69,9 69,0 66,8 63,1 57,1 73,8 45,8 (1) 72,4 70,7 70,2 70,5 69,5 66,6 58,0 75,6 47,6 (2) 72,4 70,7 70,0 69,7 68,1 65,0 57,1 74,6 46,6 (1) 67,6 71,1 74,9 73,2 72,5 69,6 57,0 78,6 50,6 (2) 67,6 70,9 73,2 71,3 70,3 66,9 55,7 76,6 48,6 (3) 61,8 69,9 71,9 68,8 67,6 65,3 53,6 74,6 46,6 (1) 80,3 72,4 76,7 75,9 75,4 70,2 62,3 81,0 53,0 (2) 80,3 72,3 75,2 74,9 73,9 68,0 61,3 79,7 51,7 (3) 71,6 66,6 72,4 68,4 68,4 64,3 53,9 74,6 46,6 (1) 80,3 72,6 76,1 75,8 77,6 74,2 67,3 82,5 54,5 (2) 80,3 72,4 74,8 74,9 75,4 71,2 64,8 80,6 52,6 (3) 71,8 67,0 69,7 68,2 71,5 68,4 59,4 76,0 48,0 (1) 80,3 73,5 77,1 76,3 77,2 71,4 65,0 82,1 54,1 (2) 80,3 72,9 75,4 75,1 75,1 68,9 63,1 80,4 52,4 (3) 73,7 67,7 72,1 69,7 70,7 64,8 57,2 75,8 47,8 (1) 71,9 67,9 74,1 72,5 73,8 69,5 57,0 78,7 50,7 (2) 71,9 67,9 72,3 69,9 69,8 66,1 56,0 75,7 47,7 (3) 62,0 63,0 70,4 67,4 68,6 65,0 55,0 74,0 46,0 (1) 83,3 75,4 79,7 78,9 78,4 73,2 65,3 84,0 56,0 (2) 83,3 75,3 78,2 77,9 76,9 71,0 64,3 82,7 54,7 (3) 74,6 69,6 75,4 71,4 71,4 67,3 56,9 77,6 49,6 (1) 83,3 75,6 79,1 78,8 80,6 77,2 70,3 85,5 57,5 (2) 83,3 75,4 77,8 77,9 78,4 74,2 67,8 83,6 55,6 (3) 74,8 70,0 72,7 71,2 74,5 71,4 62,4 79,0 51,0 (1) 83,3 76,5 80,1 79,3 80,2 74,4 68,0 85,1 57,1 (2) 83,3 75,9 78,4 78,1 78,1 71,9 66,1 83,4 55,4 (3) 76,7 70,7 75,1 72,7 73,7 67,8 60,2 78,8 50,8 (1) The above data shows noise levels without isolation for compressor (standard unit). (2) The above data shows noise levels with isolation for compressor (optional). (3) The above data shows noise levels with Kit low noise (optional). - Global sound power level measured in compliance with ISO standard 3744 and under Eurovent certification program. - Sound pressure in db(a) calculated at 10 m, in a free field on a reflecting surface, is given as a guide only and with a directibility of +/- 3 dba. - Only the sound power spectrum and the global sound power value are used in determining pressure characteristics on site. - The above data shows noise levels of standard unit and unit with compressor isolation when unit s fan is working on cooling or heating mode at maximum speed. - The above data shows noise levels of unit with Kit low noise when cooling only units, or heat pump units (on cooling mode) are working with outdoor temperatures of 3, because on heating mode the Kit low noise is disabled. 9

11 SOUND PRESSURE/SOUND POWER LEVEL Specctrum per octave band db(a) 125 Hz 250 Hz 500 Hz 1000Hz 2000 Hz 4000 Hz 8000 Hz Sound Power Lw db(a) Sound pressure at 10m Lp db(a) 128D (1) 84,2 80,8 82,1 85,6 83,4 77,0 69,3 89,2 61,2 (2) 84,2 80,7 81,0 84,6 81,3 74,7 68,0 87,7 59,7 (3) 75,0 73,1 77,2 79,8 77,6 72,2 63,8 83,5 55,5 152D (1) 84,2 80,8 82,1 85,4 84,6 78,6 70,9 89,7 61,7 (2) 84,2 80,7 80,9 84,6 82,2 76,0 69,0 88,1 60,1 (3) 75,0 73,3 76,9 80,0 79,4 74,3 66,1 84,4 56,4 112D (1) 76,3 75,5 79,7 80,1 79,2 73,8 66,8 84,7 56,7 (2) 76,3 74,7 77,8 79,1 76,3 70,7 64,1 82,8 54,8 (3) 70,6 70,7 75,6 75,2 75,3 70,0 63,2 80,4 52,4 128D (1) 76,3 75,5 79,7 80,1 79,2 73,8 66,8 84,7 56,7 (2) 81,9 78,8 80,2 82,4 79,4 73,3 66,7 85,9 57,9 (3) 73,4 72,6 77,5 77,4 76,4 71,4 64,1 82,1 54,1 152D (1) 84,2 81,0 82,3 85,5 84,4 77,3 69,6 89,5 61,5 (2) 84,2 80,8 81,0 84,6 82,0 75,1 68,0 88,0 60,0 (3) 75,0 73,7 77,1 80,0 79,0 72,7 64,1 84,1 56,1 OPTION FP1/FP2 Specctrum per octave band db(a) 125 Hz 250 Hz 500 Hz 1000Hz 2000 Hz 4000 Hz 8000 Hz Sound Power Lw db(a) Sound pressure at 10m Lp db(a) 100D FP1 128D FP1 152D FP1 100D FP2 128D FP2 152D FP2 (1) 84,2 81,0 82,0 84,4 82,0 75,6 69,3 88,0 60,04 (2) 84,2 80,8 81,0 84,1 80,7 73,9 67,9 87,2 59,24 (1) 84,2 81,1 82,7 84,6 82,4 76,4 69,6 88,4 60,4 (2) 84,2 80,8 81,4 84,2 81,0 74,4 68,2 87,5 59,45 (1) 84,2 80,9 81,9 84,4 81,5 75,2 68,5 87,8 59,8 (2) 84,2 80,7 80,9 84,1 80,4 73,6 67,5 87,1 59,12 (1) 96,4 93,6 91,7 93,1 89,5 86,4 81,9 97,0 68,99 (2) 96,4 93,6 91,6 93,0 89,3 86,3 81,8 96,9 68,90 (1) 96,4 93,6 91,8 93,1 89,6 86,5 81,9 97,0 69,04 (2) 96,4 93,6 91,6 93,0 89,4 86,3 81,8 96,9 68,92 (1) 96,4 93,6 91,7 93,1 89,4 86,3 81,9 97,0 68,96 (2) 96,4 93,6 91,6 93,0 89,3 86,2 81,8 96,9 68,88 (1) The above data shows noise levels without isolation for compressor (standard unit). (2) The above data shows noise levels with isolation for compressor (optional). (3) The above data shows noise levels with Kit low noise (optional). - Global sound power level measured in compliance with ISO standard 3744 and under Eurovent certification program. - Sound pressure in db(a) calculated at 10 m, in a free field on a reflecting surface, is given as a guide only and with a directibility of +/- 3 dba. - Only the sound power spectrum and the global sound power value are used in determining pressure characteristics on site. - The above data shows noise levels of standard unit and unit with compressor isolation when unit s fan is working on cooling or heating mode at maximum speed. - The above data shows noise levels of unit with Kit low noise when cooling only units, or heat pump units (on cooling mode) are working with outdoor temperatures of 3, because on heating mode the Kit low noise is disabled. 10

12 COOLING CAPACITIES / E/ 036 Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A / E/ 048 Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): / E/ 060 Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity: Output kw refers to the comprssor duty Power input: Input kw refers to the compressor + fan motor duty 18E/ 070 Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A 11

13 COOLING CAPACITIES 22E/ E/ 43E Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): N/A N/A Power input (Kw): N/A N/A 24E / 24E 48D/ 48D Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): N/A Power input (Kw): N/A 32E/ 32E 64D/ 64D Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): N/A Power input (Kw): N/A 38E/ 38E 76D/ 76D Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): N/A Power input (Kw): N/A 12

14 COOLING CAPACITIES 86D/ 86D 100D Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A COOLING MODE Total capacity (Kw): 62,53 59,98 57,70 54,01 50,22 Power input (Kw): 21,57 23,25 24,84 27,55 30,47 Total capacity (Kw): 75,10 72,20 69,39 65,05 60,61 Power input (Kw): 22,14 23,81 25,55 28,44 31,62 Total capacity (Kw): 89,39 87,42 82,51 77,49 72,31 Power input (Kw): 22,87 23,81 26,41 29,40 32,77 Total capacity (Kw): 105,55 102,79 97,12 91,34 85,39 Power input (Kw): 23,86 24,95 27,52 30,55 34,03 112D 128D Total capacity (Kw): N/A N/A Power input (Kw): N/A N/A Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A COOLING MODE Total capacity (Kw): 82,17 79,08 75,71 70,76 65,68 Power input (Kw): 29,70 31,74 34,07 37,67 41,53 Total capacity (Kw): 98,62 95,73 90,80 84,97 79,03 Power input (Kw): 30,53 32,21 35,28 39,18 43,42 Total capacity (Kw): 117,65 114,22 107,65 100,87 93,97 Power input (Kw): 31,35 33,08 36,69 40,79 45,33 Total capacity (Kw): 139,88 133,87 126,29 118,52 110,55 Power input (Kw): 32,17 34,76 38,43 42,66 47,44 128D 152D Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): 101,22 97,16 92,52 85,90 79,13 Power input (Kw): 37,25 39,63 42,55 47,04 52,04 Total capacity (Kw): Power input (Kw): Total capacity (Kw): 121,83 118,79 111,23 103,46 95,60 Power input (Kw): 38,60 40,17 44,36 49,11 54,37 Total capacity (Kw): Power input (Kw): Total capacity (Kw): 145,97 140,75 132,00 123,02 113,94 Power input (Kw): 39,78 42,14 46,48 51,43 56,93 Total capacity (Kw): N/A Power input (Kw): N/A Total capacity (Kw): 174,77 164,90 154,84 144,60 134,18 Power input (Kw): 40,65 44,52 49,01 54,10 59,84 152D Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): Power input (Kw): Total capacity (Kw): N/A Power input (Kw): N/A Total capacity: Output kw refers to the comprssor duty Power input: Input kw refers to the compressor + fan motor duty 13

15 HEATING CAPACITIES Condensing ºC Condensing ºC 6/ Total capacity (Kw): 5,31 5,25 5,18 5,12 5,05 4,99 Power input (Kw): 1,00 1,13 1,28 1,44 1,62 1,82 6/ Total capacity (Kw): 14,48 14,26 14,04 13,81 13,57 13,32 Power input (Kw): 2,81 3,12 3,48 3,87 4,30 4,77 Total capacity (Kw): 5,63 5,57 5,50 5,42 5,34 5,27 Power input (Kw): 1,00 1,13 1,27 1,43 1,61 1,82 Total capacity (Kw): 15,41 15,17 14,92 14,65 14,38 14,10 Power input (Kw): 2,82 3,13 3,48 3,87 4,31 4,78 12/ Total capacity (Kw): 6,19 6,11 6,02 5,93 5,83 5,73 Power input (Kw): 1,00 1,12 1,26 1,42 1,60 1,80 12/ Total capacity (Kw): 17,02 16,72 16,41 16,09 15,77 15,44 Power input (Kw): 2,85 3,15 3,50 3,89 4,32 4, Condensing ºC Condensing ºC 6/ Total capacity (Kw): 6,83 6,75 6,67 6,58 6,50 6,42 Power input (Kw): 1,33 1,49 1,68 1,89 2,12 2,38 6/ Total capacity (Kw): 17,81 17,50 17,17 16,83 16,50 16,19 Power input (Kw): 3,37 3,73 4,13 4,59 5,10 5,67 Total capacity (Kw): 7,25 7,17 7,07 6,97 6,87 6,77 Power input (Kw): 1,33 1,49 1,68 1,88 2,11 2,38 Total capacity (Kw): 18,95 18,59 18,21 17,83 17,45 17,11 Power input (Kw): 3,38 3,73 4,14 4,59 5,10 5,67 12/ Total capacity (Kw): 7,97 7,86 7,75 7,62 7,49 7,36 Power input (Kw): 1,32 1,48 1,67 1,87 2,10 2,36 12/ Total capacity (Kw): 20,86 20,41 19,95 19,49 19,05 18,66 Power input (Kw): 3,40 3,74 4,14 4,60 5,11 5, Condensing ºC Condensing ºC 6/ Total capacity (Kw): 8,18 8,09 7,99 7,88 7,77 7,67 Power input (Kw): 1,54 1,74 1,96 2,21 2,49 2,80 6/ Total capacity (Kw): 19,37 19,10 18,79 18,50 18,19 17,91 Power input (Kw): 3,70 4,10 4,57 5,10 5,70 6,40 Total capacity (Kw): 8,69 8,59 8,47 8,35 8,22 8,10 Power input (Kw): 1,54 1,74 1,96 2,20 2,48 2,79 Total capacity (Kw): 20,57 20,27 19,94 19,59 19,24 18,92 Power input (Kw): 3,71 4,12 4,58 5,10 5,71 6,39 12/ Total capacity (Kw): 9,55 9,43 9,29 9,14 8,98 8,82 Power input (Kw): 1,53 1,73 1,94 2,19 2,46 2,77 12/ Total capacity (Kw): 22,60 22,25 21,85 21,44 21,02 20,60 Power input (Kw): 3,74 4,14 4,60 5,12 5,72 6,40 6/ 12/ 036 Condensing ºC Total capacity (Kw): 9,59 9,49 9,37 9,24 9,11 8,98 Power input (Kw): 1,81 2,03 2,29 2,57 2,90 3,26 Total capacity (Kw): 10,19 10,07 9,94 9,79 9,64 9,48 Power input (Kw): 1,80 2,03 2,28 2,57 2,89 3,25 Total capacity (Kw): 11,20 11,05 10,89 10,71 10,52 10,33 Power input (Kw): 1,79 2,02 2,27 2,55 2,87 3,23 Total capacity: Heating data kw for a heatpump condensing unit. Heating data ~0.95(cooling data+compressor power input) Power input: Input kw refers to the compressor + fan motor duty 6/ 12/ 048 Condensing ºC Total capacity (Kw): 12,34 12,11 11,88 11,65 11,45 11,28 Power input (Kw): 2,35 2,61 2,89 3,21 3,57 3,99 Total capacity (Kw): 13,11 12,85 12,60 12,35 12,12 11,91 Power input (Kw): 2,33 2,60 2,88 3,20 3,56 3,98 Total capacity (Kw): 14,41 14,13 13,84 13,56 13,29 13,05 Power input (Kw): 2,30 2,57 2,86 3,19 3,55 3,97 14

16 HEATING CAPACITIES 24E 76D Condensing ºC Condensing ºC 6/ Total capacity (Kw): 21,00 20,53 20,13 19,84 19,61 19,46 Power input (Kw): 4,23 4,63 5,13 5,73 6,42 7,20 6/ Total capacity (Kw): 74,39 72,95 71,64 70,49 69,49 68,68 Power input (Kw): 14,37 15,81 17,52 19,49 21,75 24,30 Total capacity (Kw): 22,36 21,82 21,37 21,02 20,73 20,54 Power input (Kw): 4,23 4,62 5,12 5,71 6,41 7,20 Total capacity (Kw): 78,91 77,24 75,78 74,49 73,35 72,39 Power input (Kw): 14,43 15,84 17,53 19,51 21,77 24,34 12/ Total capacity (Kw): 24,58 23,93 23,37 22,91 22,54 22,26 Power input (Kw): 4,27 4,63 5,10 5,69 6,38 7,18 12/ Total capacity (Kw): 86,49 84,53 82,75 81,14 79,70 78,46 Power input (Kw): 14,56 15,91 17,56 19,52 21,80 24,39 32E 86D Condensing ºC Condensing ºC 6/ Total capacity (Kw): 30,51 29,96 29,45 28,99 28,55 28,15 Power input (Kw): 5,73 6,36 7,08 7,90 8,80 9,79 6/ Total capacity (Kw): 86,51 84,96 83,70 82,66 81,82 81,12 Power input (Kw): 16,72 18,48 20,63 23,12 25,95 29,09 Total capacity (Kw): 32,34 31,72 31,15 30,61 30,12 29,67 Power input (Kw): 5,72 6,34 7,06 7,88 8,79 9,80 Total capacity (Kw): 91,75 89,98 88,48 87,25 86,22 85,39 Power input (Kw): 16,80 18,49 20,58 23,07 25,92 29,10 12/ Total capacity (Kw): 35,42 34,69 34,02 33,37 32,79 32,23 Power input (Kw): 5,71 6,32 7,03 7,85 8,77 9,80 12/ Total capacity (Kw): 100,6 98,39 96,47 94,86 93,48 92,34 Power input (Kw): 17,05 18,57 20,56 22,99 25,84 29,07 38E 100D Condensing ºC Condensing ºC 6/ Total capacity (Kw): 37,21 36,47 35,82 35,24 34,75 34,34 Power input (Kw): 7,19 7,91 8,76 9,75 10,88 12,15 6/ Total capacity (Kw): 96,10 93,87 91,95 90,27 88,82 87,49 Power input (Kw): 17,71 19,31 21,37 23,83 26,69 29,90 Total capacity (Kw): 39,45 38,62 37,89 37,24 36,69 36,20 Power input (Kw): 7,21 7,92 8,76 9,75 10,89 12,17 Total capacity (Kw): 102,27 99,74 97,51 95,53 93,82 92,34 Power input (Kw): 17,91 19,40 21,37 23,79 26,63 29,87 12/ Total capacity (Kw): 43,24 42,27 41,38 40,57 39,85 39,23 Power input (Kw): 7,28 7,95 8,78 9,76 10,90 12,20 12/ Total capacity (Kw): 112,6 109,56 106,83 104,40 102,26 100,44 Power input (Kw): 18,38 19,65 21,45 23,76 26,55 29,79 43E 128D Condensing ºC Condensing ºC 6/ Total capacity (Kw): 43,25 42,48 41,85 41,33 40,91 40,56 Power input (Kw): 8,36 9,24 10,31 11,56 12,98 14,55 6/ Total capacity (Kw): 123,82 121,24 119,00 117,05 115,36 113,86 Power input (Kw): 23,58 25,86 28,66 31,95 35,70 39,89 Total capacity (Kw): 45,87 44,99 44,24 43,63 43,11 42,70 Power input (Kw): 8,40 9,24 10,29 11,53 12,96 14,55 Total capacity (Kw): 131,51 128,58 126,01 123,75 121,78 120,05 Power input (Kw): 23,73 25,90 28,63 31,89 35,65 39,88 12/ Total capacity (Kw): 50,29 49,19 48,23 47,43 46,74 46,17 Power input (Kw): 8,52 9,29 10,28 11,50 12,92 14,53 12/ Total capacity (Kw): 144,51 140,92 137,75 134,92 132,44 130,26 Power input (Kw): 24,13 26,08 28,65 31,82 35,55 39,82 48D 152D Condensing ºC Condensing ºC 6/ Total capacity (Kw): 44,06 42,99 42,08 41,36 40,82 40,43 Power input (Kw): 9,16 9,95 10,94 12,14 13,52 15,09 6/ Total capacity (Kw): 152,38 148,95 145,85 143,04 140,61 138,52 Power input (Kw): 29,60 32,41 35,75 39,67 44,16 49,27 Total capacity (Kw): 46,91 45,69 44,69 43,84 43,17 42,70 Power input (Kw): 9,19 9,94 10,91 12,10 13,49 15,08 Total capacity (Kw): 161,82 158,02 154,51 151,41 148,62 146,17 Power input (Kw): 29,76 32,50 35,80 39,68 44,17 49,29 12/ Total capacity (Kw): 51,68 50,24 48,99 47,95 47,07 46,40 Power input (Kw): 9,29 9,97 10,89 12,05 13,44 15,04 12/ Total capacity (Kw): 177,67 173,22 169,06 165,24 161,79 158,68 Power input (Kw): 30,10 32,71 35,91 39,73 44,19 49,30 6/ 12/ 64D Condensing ºC Total capacity (Kw): 61,01 59,92 58,89 57,98 57,11 56,30 Power input (Kw): 11,46 12,72 14,17 15,79 17,59 19,57 Total capacity (Kw): 64,68 63,44 62,30 61,22 60,25 59,35 Power input (Kw): 11,43 12,68 14,12 15,76 17,58 19,60 Total capacity (Kw): 70,84 69,38 68,03 66,75 65,58 64,47 Power input (Kw): 11,42 12,63 14,06 15,70 17,55 19,61 15 Total capacity: Heating data kw for a heatpump condensing unit. Heating data ~0.95(cooling data+compressor power input) Power input: Input kw refers to the compressor + fan motor duty

17 UNIT DIMENSIONS b A B C a c model ksck 10e kjhk 036 models ksck 12e-16e kjhk models ksck 18e-22e kjhk Access p anel to electrical box Access p anel to electrical box Access p anel to electrical box Power supply Gas line Liquid line Power supply Gas line Liquid line Power supply Gas line Liquid line models ksck/knhk 24e models ksck/knhk 32e-38e-43e 24e Main switch (optional) Main switch (optional) Access to gas and liquid lines Power supply Power supply Electrical box 660 Access to gas and liquid lines Electrical box 980 models ksck/knhk 48d-64d-76d-86d models ksck112d-128d-152d knhk 100D-128D-152D Main switch (optional) Main switch (optional) Power supply Electrical box Access to gas and liquid lines Electrical box 1195 Power supply Access to gas and liquid lines 2250 Power supply

18 BELGIUM, LUXEMBOURG : LENNOX BENELUX N.V./S.A. CZECH REPUBLIC : LENNOX JANKA a.s. FRANCE : LENNOX FRANCE GERMANY : LENNOX DEUTSCHLAND GmbH IRELAND : LENNOX IRELAND NETHERLANDS : LENNOX BENELUX B.V. POLAND : LENNOX POLSKA Sp. z o. o. PORTUGAL : LENNOX PORTUGAL Lda. RUSSIA : LENNOX DISTRIBUTION MOSCOW SLOVAKIA : LENNOX SLOVENSKO s.r.o. SPAIN : LENNOX REFAC S.A. UKRAINE : LENNOX DISTRIBUTION KIEV UNITED KINGDOM : LENNOX UK OTHER COUNTRIES : LENNOX DISTRIBUTION COD: MSL103E Due to Lennox s ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by 18a qualified installer and servicing agency.

PRODUCT CATALOGUE CHILLER ECOMAX

PRODUCT CATALOGUE CHILLER ECOMAX PRODUCT CATALOGUE CHILLER ECOMAX English/02-2005 AIR COOLED CHILLER INTRODUCTION TO THE RANGE The simple and robust design of the Ecomax range brings real benefits in terms of savings in investment, operation

More information

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC English/09-2003 CHILLED WATER CASSETTE! INTRODUCTION TO THE RANGE The units are available in the following versions:! 2 pipes! 2 pipes - 2 wires (electrical

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

Enhanced Air Conditioning

Enhanced Air Conditioning 4SCU16LT Split System Enhanced Air Conditioning COMPRESSOR High-efficiency 2 stage Copeland UltraTech TM scroll compressor R410a refrigerant Grommet-mounted compressor for quiet operation Internally protected

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3

More information

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½

More information

Product Data PH13NB PH13PB FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NB PH13PB FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: PH13PB 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

... RTU Technical Manual. Packaged Air Conditioning Unit...

... RTU Technical Manual. Packaged Air Conditioning Unit... ... RTU Technical Manual Packaged Air Conditioning Unit... Index. CODING AND MODELS. WORKING LIMITS. TECHNICAL SPECIFICATIONS. PERFORMANCE TABLES. TECHNICAL SPECIFICATIONS FOR OPTIONAL EQUIPMENT. ELECTRONIC

More information

4SHP13LE Product Specifications

4SHP13LE Product Specifications 4SHPLE Product Specifications S SPLIT SYSTEM HEAT PUMP FORM NO. 4SHPLE-00 (0/04) Service valves positioned for quick installation and easy service Low pressure switch for loss of charge system protection

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

4SHP13LB PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP COIL DESIGN ACCESSORIES. COMPRESSOR Low ambient kit Crank Case Heater Freezestat

4SHP13LB PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP COIL DESIGN ACCESSORIES. COMPRESSOR Low ambient kit Crank Case Heater Freezestat 4SHP13LB 13 SPLIT SYSTEM HEAT PUMP PRODUCT SPECIFICATIONS FORM NO. 4SHP13LB-100 (11/2016) Reliable, solid-state, time-initiated, temperature-terminated defrost system Service valves positioned for quick

More information

HSH5. Product Specifications. Quiet Comfort DXC 1500

HSH5. Product Specifications. Quiet Comfort DXC 1500 ENVIRONMENTALLY SOUND REFRIGERANT HSH5 Quiet Comfort DXC 1500 Product Specifications 15 SINGLE STAGE HEAT PUMP WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

4SHP18LS PRODUCT SPECIFICATIONS

4SHP18LS PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS 18 SEER SPLIT SYSTEM ENHANCED HEAT PUMP FORM NO. -100 (06/2014) COMPONENTS Full metal louvered panels remove for easy coil cleaning and service Bi-directional filter drier for long-lasting

More information

6,3 108 kw R410A UP FLOW DOWN FLOW !"#$% "&'("!%)*(% "&+*'*"&$(#%,*'-%($."'$%)*(% ""!$+% "&+$&#$(%"(%/0*!'1*&%,)'$(% ""!$+% "&+$&#$( RCGROUP SpA

6,3 108 kw R410A UP FLOW DOWN FLOW !#$% &'(!%)*(% &+*'*&$(#%,*'-%($.'$%)*(% !$+% &+$&#$(%(%/0*!'1*&%,)'$(% !$+% &+$&#$( RCGROUP SpA 15!"#$% "&'("!%)*(% "&+*'*"&$(#%,*'-%($."'$%)*(% ""!$+% "&+$&#$(%"(%/0*!'1*&%,)'$(% ""!$+% "&+$&#$( 6,3 108 kw EC AC UP DOWN R410A 16 VERSIONS: DX (R410A) - Plug Fan Direct expansion air conditioner in

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

13 SEER Light Commercial 3 Phase

13 SEER Light Commercial 3 Phase 13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

WQL/WQH/WQRC 524 to 1204

WQL/WQH/WQRC 524 to 1204 Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

N2AE - 50 Hz PRODUCT SPECIFICATIONS

N2AE - 50 Hz PRODUCT SPECIFICATIONS ISO 9001:2000 REGISTERED N2AE - 50 Hz PRODUCT SPECIFICATIONS 50 Hz AIR CONDITIONING CONDENSING UNIT 230 Volt, 1-phase, 50 Hz in 1½, 2, 2½, 3, 4 tons 400 Volt, 3-phase, 50 Hz in 3, 3½, 4, 5 tons REFRIGERATION

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

LUI / LUO. Condensing Units

LUI / LUO. Condensing Units UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK Air Cooled CHILLER CAPACITY: 25-206 TR 2 Company Business Awal Gulf Manufacturing, located at Bahrain is the one of the leading manufacturers of air conditioning and refrigeration products in Middle East

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information