V31. Variable Area Flowmeter
|
|
- Prudence Harrison
- 5 years ago
- Views:
Transcription
1 Variable Area lowmeter V Housing in stainless steel Borosilicate glass Only ealing rings ervice kind construction Replace V / V / V Limit switches (Options) Chip guard Operating principle The measuring element is composed of a float and a conical glass tube. A medium flows from the bottom to the top through the measuring ring, lifting the float until the buoyancy force and the weight of the float establish equilibrium. The height of the float in the measuring ring is the measure of the flow. The flow rate is read directly from a scale inscribed on the glass. The readings obtained apply solely to the medium for which the device has been calibrated or for a medium with the same density and viscosity. Applications The metering device is used for flow metering, dosing, monitoring, and control of liquid and gas media in pipes. The scale on the device shows the flow rate expressed as volume or mass per unit of time. Applications: flow metering, dosing, monitoring, and control of liquid and gas media. The device can be fitted with up to two limit switches for purposes of process monitoring.
2 Technical Data Measuring range Turndown ratio : Accuracy class (according to VDE/VDI, sheet low direction Water Air Water Air l/h Nl/h l/h 8 8 Nl/h l/h <= l/h m³/h >= l/h l/h <= Nl/h m³/h >= Nl/h Liquids,% Gases,% q G % from bottom to top Materials Measuring tube Borosilicat glass Connections loat.7, PVD, PVC.7, aluminium, PVD loat guiding.7 eals loat top Viton, EPDM, EP/KM PVD / stainless steel Protection body. hatter protection Polycarbonat Ambient conditions Ambient temperature +8 C ( +7 ) Ambient temperature PVC +8 C ( +7 ) torage temperature + C ( + ) Climatic category Weatherproof and/or unheated operation site, class C according to DIN IEC part Medium Conditions Inlet and outlet straight Pressure Loss mallest measuring range Largest measuring range Dimensions for measrured variable hock resistance / vibration resistance The device should be protected against extreme shock and vibration, either of which could cause damage Pressure Resistance Ranges B bis C7 max. bar (at max. 8 C ; 7 ) Ranges D bis D8 max. bar (at max. 8 C ; ) Media Temperature tatus Water Air covered to C and, bar abs Ranges E bis E max. bar (at max. 8 C ; 7 ) Connections in PVD max. bar (at max. C ; 8 ) max. bar (at max. C ; ) max., bar (at max. C ; ) Connections in PVC max. bar (at max. C ; 8 ) max. bar (at max. C ; ) max., bar (at max. C ; ) loat material st.st. / Aluminium + C (+ +7 ) loat material PVD + C (+ +7 ) PVC Glue connection + C (+ + ) liquid or gaseous Density Liquids <=, kg/l Gases / Inlet and outlet straight are not required as long as the flow profile is laminar. On strongly non laminar flow profiles e.g. regulating and shuttoff devices inlet straight of mm, see also directive VDI/VDE see measuring ranges Limit contacts Model witching type Power K7A reed contact N/O AC V/, A / VA K7B reed contact N/C DC V/, A / W K reed contact PDT V AC/DC/,A/VA/W Ki inductive contact N/C V DC
3 Measuring ranges Liquids V model Pressure loss mbar(psi) loat.7 c/w and w/o guiding loat.7+ magnet loat.7 viscosity stable loat PVD weighted w. magnet G B (,), 7 Gases V model Connection izes tandard Ranges acc. Range code tandard ranges for liquids l/h (p=kg/l(, lb/cu.ft), viskosity mpas(cp)) (turndown ratio :) /" B, /8" B /" B,, B 8 8, B G C (,9),, /" C, 9 9 /8" C 8 8 /" C C (,8), 7, 7 C C7 8 8 G D 9 (,8) /" D /" D " D D 7 7 D (,) D7 8 8 D8 (,8) D G E (,) 8 8 " E /" E /" E " E Connection izes tandard Ranges acc. Range code Pressure loss mbar(psi) loat Aluminum c/w and w/o guiding loat Aluminum + magnet loat PVD loat PVD weighted w. magnet tandard ranges for air Nl/h (Pabs =, bar(,9psi) at T= C(8 ), p=,9kg/m³, V=,8 mpas) (Turndown ratio :) G B (,8) /" B /8" B 8 8 /" B 8 8 B B G C /" C /8" C /" C C (,8) C C G D 9 (,8) /" D 8 8 /" D 9 9 " D D D (,) D7 D8 (,8) D9 7 G E (,) 7 7 " E /" E 8 8 /" E " E 8 8
4 Construction details V Model Ø AR a b W W emale thread Hose connector Ø.7 9 Body Ø Ø Weights Treaded conn. langed conn G /,7 Kg DN, Kg G /,7 Kg DN, Kg G, Kg DN,9 Kg 7 G, Kg DN 8,9 Kg 7 G / NPT ¼",?", ½" G / NPT ¾", ", ¼" G / NPT ¼", ½", " Ø, Ø 9 Connection Bonded connection DN /// PN DN d = mm Ø 9, Ø, Ø 8 DN d = mm Ø 8, Ø tandard connections are underlined DN d = mm DN / PN DN / PN DN PN lange AME ¼",?", ½" lb AME ", ½" lb AME ½", ", ½" lb file: V_flyer_en_. Heinrichs Messtechnik GmbH P. O. Box RobertPertheltraße 9 Phone D8 Cologne D79 Cologne ax info@heinrichsmt.com
5 VARIABLE AREA LOWMETER Glass Tube ( / l/h Water) max. bar Temp. min. C, max. 8 C Accuracy:,% Gas /,% Liquid q G =% Description Block Nr.,,,,, V Base price Thread G ¼"() 7 mm PVD G ¼"() 7 mm G ⅜"() 7 mm PVD G ⅜"() 7 mm G ½"() 7 mm PVD G ½"() 7 mm NPT ¼"() 7 mm PVD NPT ¼"() 7 mm NPT ⅜"() 7 mm PVD NPT ⅜"() 7 mm NPT ½"() 7 mm PVD NPT ½"() 7 mm lange B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm Hose clip ½" inner diameter Ø mm ½" inner diameter Ø mm PVD ⅜" inner diameter Ø9 mm ⅜" inner diameter Ø9 mm PVD Type of float, Material guide rod.7.7 PVD weighted 8 Aluminium. 99 Measuring range stainless steel float (not guided) BW HO: l/h kg/m³, mpas BW HO: l/h kg/m³, mpas BW HO: l/h kg/m³, mpas BW HO:, l/h kg/m³, mpas BW HO: 8 8 l/h kg/m³, mpas BW HO: l/h kg/m³, mpas Measuring range PVD float (weighted) BW HO:, l/h kg/m³, mpas BW HO:, l/h kg/m³, mpas BW HO: l/h kg/m³, mpas BW HO:, l/h kg/m³, mpas BW HO:, l/h kg/m³, mpas BW HO: l/h kg/m³, mpas Measuring range Aluminium float (not guided) BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: 8 8 Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C
6 Measuring range PVD float (weighted) BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: 8 8 Nl/h mbar, C BL Air: Nl/h mbar, C BL Air: Nl/h mbar, C B V X A Gasket EPDM Viton EP/Perfluor loat stop PVD Union nut Aluminium lacquered KM KM hatter protection max. 8 C with required for ATEX approval electrical output x K 7 A Contact closes below limit x K 7 B Contact closes above limit x K two way contact x K i Inductive contact closes on descending float x K i Inductive contact closes on descending float cale %cale (HO) Measuring rangescale (HO) %cale (Medium) Measuring rangescale (Medium) graven scale Works certificate. EN ) Inspection certificate. with materialanalysis (DIN EN :) on stainless steel parts ) Calibration certificate tandard confirmed accuracy class (..) Points point protocol pecial scaling Accuracy % 9 Cleaning according works standard (free of oil and grease) Cleaning of stainless steel parts with marking free of oil and grease Pressure / leakage test pressure test according EN with certificate. leakage test according EN with certificate. ATEX GD IIC TX (BV ATEX H/B 9) Marking stainless steel plate xmm Accessories with (separate specification) requires shatter protection
7 VARIABLE AREA LOWMETER Glass Tube ( / l/h Wasser) max. bar Temp. min. C, max. 8 C Accuracy:,% Gas /,% Liquid q G =% Description Block Nr.,,,,, V Base price Thread G ¼"() 7 mm PVD G ¼"() 7 mm G ⅜"() 7 mm PVD G ⅜"() 7 mm G ½"() 7 mm PVD G ½"() 7 mm NPT ¼"() 7 mm PVD NPT ¼"() 7 mm NPT ⅜"() 7 mm PVD NPT ⅜"() 7 mm NPT ½"() 7 mm PVD NPT ½"() 7 mm lange B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm B DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm AB DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm 9B DN PN/// orm B EN9 mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ½" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R ¾" lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm R " lbs R AME B. mm Hose clip ½" inner diameter Ø mm ½" inner diameter Ø mm PVD ⅜" inner diameter Ø9 mm ⅜" inner diameter Ø9 mm PVD Type of float, Material guide rod guided with.7 with magnet.7 independent of viscosity mpa s (cp) with PVD PVD weighted 7 PVD with magnet 8 Aluminium. 9 Aluminium. guided with Aluminium. with magnet 99 Measuring range stainless steel float (guide and not guided) CW HO:, l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO:, l/h kg/m³, mpas CW HO: l/h kg/m³, mpas C7W HO: l/h kg/m³, mpas Measuring range stainless steel float with magnet CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: 8 8 l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas C7W HO: 8 8 l/h kg/m³, mpas Measuring range stainless steel float independent of viscosity mpa s (cp) CW HO: l/h kg/m³, mpas CW HO:, l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas C7W HO: l/h kg/m³, mpas Measuring range PVD float CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C
8 CL Air: Nl/h mbar, C C7L Air: Nl/h mbar, C Measuring range PVD float (weighted or with magnet) CW HO:, l/h kg/m³, mpas CW HO: 99 l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: l/h kg/m³, mpas CW HO: 7,7 l/h kg/m³, mpas CW HO: l/h kg/m³, mpas C7W HO: l/h kg/m³, mpas Measuring range PVD float (with magnet) CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: 77 Nl/h mbar, C C7L Air: 99 Nl/h mbar, C Measuring range Aluminium float (guided and not guided) CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C C7L Air: 8 8 Nl/h mbar, C Measuring range Aluminium float (with magnet) CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: Nl/h mbar, C CL Air: 8 8 Nl/h mbar, C C7L Air: Nl/h mbar, C B V X A Gasket EPDM Viton EP/Perfluor loat stop PVD Union nut Aluminium lacquered KM KM hatter protection max. 8 C with required for ATEX approval electrical output x K 7 A Contact closes below limit x K 7 B Contact closes above limit x K two way contact x K i Inductive contact closes on descending float x K i Inductive contact closes on descending float cale %cale (HO) Measuring rangescale (HO) %cale (Medium) Measuring rangescale (Medium) graven scale Works certificate. EN ) Inspection certificate. with materialanalysis (DIN EN :) on stainless steel parts ) Calibration certificate tandard confirmed accuracy class (..) Points point protocol pecial scaling Accuracy % 9 Cleaning according works standard (free of oil and grease) Cleaning of stainless steel parts with marking free of oil and grease Pressure / leakage test pressure test according EN with certificate. leakage test according EN with certificate. ATEX GD IIC TX (BV ATEX H/B 9) Marking stainless steel plate xmm Accessories with (separate specification) requires shatter protection
9 VARIABLE AREA LOWMETER Glass Tube ( / l/h Wasser) max. bar Temp. min. C, max. 8 C Accuracy:,% Gas /,% Liquid q G =% Description Block Nr.,,,,, V Base price Thread G ¾"() Verschraubung 7 mm PVD G ¾"() Verschraubung 7 mm Edelstahl G "() Verschraubung 7 mm PVD G "() Verschraubung 7 mm Edelstahl NPT ¾"() Verschraubung 7 mm PVD NPT ¾"() Verschraubung 7 mm Edelstahl NPT "() Verschraubung 7 mm PVD NPT "() Verschraubung 7 mm Edelstahl lange 9B DN PN/// orm B EN9 mm PVD 9B DN PN/// orm B EN9 mm Edelstahl 9B DN PN/// orm B EN9 mm PVD 9B DN PN/// orm B EN9 mm Edelstahl 7B DN PN/// orm B EN9 mm PVD 7B DN PN/// orm B EN9 mm Edelstahl 7B DN PN/// orm B EN9 mm PVD 7B DN PN/// orm B EN9 mm Edelstahl R " lbs R AME B. mm PVD R " lbs R AME B. mm Edelstahl R " lbs R AME B. mm PVD R " lbs R AME B. mm Edelstahl R ½" lbs R AME B. mm PVD R ½" lbs R AME B. mm Edelstahl R ½" lbs R AME B. mm PVD R ½" lbs R AME B. mm Edelstahl Hose clip ¾" inner diameter Ø9 mm Edelstahl ¾" inner diameter Ø9 mm PVD " inner diameter Ø mm Edelstahl " inner diameter Ø mm PVD ½" inner diameter Ø8 mm Edelstahl ½" inner diameter Ø8 mm PVD Type of float, Material guide rod guided with.7 with magnet.7 independent of viscosity mpa s s(cp) with PVD PVD weighted 7 PVD with magnet 8 Aluminium. 9 Aluminium. guided with Aluminium. with magnet 99 Measuring range stainless steel float (guide and not guided) DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: 8 8 l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas D7W HO: l/h kg/m³, mpas D8W HO: l/h kg/m³, mpas D9W HO: l/h kg/m³, mpas Measuring range stainless steel float with magnet DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: 7 7 l/h kg/m³, mpas DW HO: 9 9 l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas D7W HO: 8 8 l/h kg/m³, mpas D8W HO: l/h kg/m³, mpas D9W HO: 8 8 l/h kg/m³, mpas Measuring range stainless steel float independent of viscosity mpa s (cp) DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: 7 7 l/h kg/m³, mpas DW HO: l/h kg/m³, mpas D7W HO: l/h kg/m³, mpas D8W HO: l/h kg/m³, mpas D9W HO: 8 8 l/h kg/m³, mpas Measuring range PVD float DL Air: Nl/h mbar, C DL Air: 8 8 Nl/h mbar, C DL Air: 9 9 Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C D7L Air: Nl/h mbar, C D8L Air: Nl/h mbar, C D9L Air: Nl/h mbar, C Measuring range PVD float (weighted or with magnet) DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: 7 7 l/h kg/m³, mpas DW HO: l/h kg/m³, mpas DW HO: l/h kg/m³, mpas D7W HO: l/h kg/m³, mpas D8W HO: l/h kg/m³, mpas
10 D9W HO: l/h kg/m³, mpas Measuring range PVD float (with magnet) DL Air: 7 7 Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: 8 8 Nl/h mbar, C D7L Air: Nl/h mbar, C D8L Air: Nl/h mbar, C D9L Air: Nl/h mbar, C Measuring range Aluminium float (guided and not guided) DL Air: 7 7 Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: 8 8 Nl/h mbar, C D7L Air: Nl/h mbar, C D8L Air: Nl/h mbar, C D9L Air: Nl/h mbar, C Measuring range Aluminium float (with magnet) DL Air: 8 8 Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C DL Air: Nl/h mbar, C D7L Air: Nl/h mbar, C D8L Air: Nl/h mbar, C D9L Air: Nl/h mbar, C Gasket B EPDM Viton KM V EP/Perfluor KM X A loat stop PVD Union nut Aluminium lacquered hatter protection max. 8 C with required for ATEX approval electrical output x K 7 A Contact closes below limit x K 7 B Contact closes above limit x K two way contact x K i Inductive contact closes on descending float x K i Inductive contact closes on descending float cale %cale (HO) Measuring rangescale (HO) %cale (Medium) Measuring rangescale (Medium) graven scale Works certificate. EN ) Inspection certificate. with materialanalysis (DIN EN :) on stainless steel parts ) Calibration certificate tandard confirmed accuracy class (..) Points point protocol pecial scaling Accuracy % 9 Cleaning according works standard (free of oil and grease) Cleaning of stainless steel parts with marking free of oil and grease Pressure / leakage test pressure test according EN with certificate. leakage test according EN with certificate. ATEX GD IIC TX (BV ATEX H/B 9) Marking stainless steel plate xmm Accessories with (separate specification) requires shatter protection
11 VARIABLE AREA LOWMETER Glass Tube (7 / l/hwasser) max. bar Temp. min. C, max. 8 C Accuracy:,% Gas /,% Liquid q G =% Description Block Nr.,,,,, V Base price Thread G ¼"() Verschraubung 7 mm PVD G ¼"() Verschraubung 7 mm Edelstahl G ½"() Verschraubung 7 mm PVD G ½"() Verschraubung 7 mm Edelstahl 7 G "() Verschraubung 7 mm PVD 7 G "() Verschraubung 7 mm Edelstahl NPT ¼"() Verschraubung 7 mm PVD NPT ¼"() Verschraubung 7 mm Edelstahl 7 NPT ½"() Verschraubung 7 mm PVD 7 NPT ½"() Verschraubung 7 mm Edelstahl 8 NPT "() Verschraubung 7 mm PVD 8 NPT "() Verschraubung 7 mm Edelstahl lange 7B DN PN/// orm B EN9 mm PVD 7B DN PN/// orm B EN9 mm Edelstahl 7B DN PN/// orm B EN9 mm PVD 7B DN PN/// orm B EN9 mm Edelstahl B DN PN/ orm B EN9 mm PVD B DN PN/ orm B EN9 mm Edelstahl B DN PN/ orm B EN9 mm PVD B DN PN/ orm B EN9 mm Edelstahl B DN PN/ orm B EN9 mm PVD B DN PN/ orm B EN9 mm Edelstahl B DN PN/ orm B EN9 mm PVD B DN PN/ orm B EN9 mm Edelstahl R ½" lbs R AME B. mm PVD R ½" lbs R AME B. mm Edelstahl R ½" lbs R AME B. mm PVD R ½" lbs R AME B. mm Edelstahl R " lbs R AME B. mm PVD R " lbs R AME B. mm Edelstahl R " lbs R AME B. mm PVD R " lbs R AME B. mm Edelstahl 7R ½" lbs R AME B. mm PVD 7R ½" lbs R AME B. mm Edelstahl 7R ½" lbs R AME B. mm PVD 7R ½" lbs R AME B. mm Edelstahl Hose clip chlauchtülle " lichte Weite Ø mm Edelstahl chlauchtülle " lichte Weite Ø mm PVD V Klebeanschluss DN d = mm 7 mm PVC Type of float, Material guide rod.7.7 guided with.7 with magnet.7 independent of viscosity mpa s (cp) with PVD PVD weighted 7 PVD with magnet 8 Aluminium. 9 Aluminium. guided with Aluminium. with magnet 99 Measuring range stainless steel float (guided) EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: 8 8 l/h kg/m³, mpas EW HO:. l/h kg/m³, mpas Measuring range stainless steel float with magnet EW HO: 8 8 l/h kg/m³, mpas EW HO: 8 8 l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: 7 7 l/h kg/m³, mpas EW HO: 9 9 l/h kg/m³, mpas Measuring range stainless steel float independent of viscosity mpa s (cp) EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas Measuring range PVD float EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: 8 8 Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C
12 Measuring range PVD float (weighted or with magnet) EW HO: l/h kg/m³, mpas EW HO: 8 8 l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: l/h kg/m³, mpas EW HO: 7 7 l/h kg/m³, mpas Measuring range PVD float (with magnet) EL Air: Nl/h mbar, C EL Air: 8 8 Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C Measuring range Aluminium float (guided and not guided) EL Air: Nl/h mbar, C EL Air: 8 8 Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C Measuring range Aluminium float (with magnet) EL Air: 7 7 Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: Nl/h mbar, C EL Air: 8 8 Nl/h mbar, C Gasket B EPDM Viton KM V EP/Perfluor KM X A loat stop PVD Union nut Aluminium lacquered hatter protection max. 8 C with required for ATEX approval electrical output x K 7 A Contact closes below limit x K 7 B Contact closes above limit x K two way contact x K i Inductive contact closes on descending float x K i Inductive contact closes on descending float cale %cale (HO) Measuring rangescale (HO) %cale (Medium) Measuring rangescale (Medium) graven scale Works certificate. EN ) Inspection certificate. with materialanalysis (DIN EN :) on stainless steel parts ) Calibration certificate tandard confirmed accuracy class (..) Points point protocol pecial scaling Accuracy % 9 Cleaning according works standard (free of oil and grease) Cleaning of stainless steel parts with marking free of oil and grease Pressure / leakage test pressure test according EN with certificate. leakage test according EN with certificate. ATEX GD IIC TX (BV ATEX H/B 9) requires shatter protection Marking stainless steel plate xmm Accessories with (separate specification)
BGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationMetal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam
Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in
More informationPlastic tube variable area flowmeter for liquids and gases
Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationVariable Area Flow Meters
JJ Series VS1 JJ Series VS3 JJ Limit switches Variable Area Flow Meters DS_Variable_Area_Flow_Meters 01/2017 185 Variable area flow meters Principle of operation Variable area flow meters are used in pipelines
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationVariable area meter F VA TUBUX M30
VA TUUX M30 The variable area meter must be fitted vertically and without tension. ontrol elements or reductions/extensions in the pipe diameter upstream or downstream of the variable area meter have no
More informationCOVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information
Durchflussmessung Flowmeters COVOL Areas of Application Operating Data Method of Operation Oscillating Piston Operating pressure, max. PN 10 (Plastic) PN 16 (Stainless Steel) Fields of operation Consumption
More informationFlap-Type Flow Meter Prall
Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional
More informationOrifice flowmeter F O N4
Special features Suitable for any mounting positions without reduction in accuracy Complies with requirements for treatment and disinfection of swimming/ bathing pools (DIN 9 643) Simple installation Direct
More informationGA 24 Heavy-duty variable area flowmeter
KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVariable-Area Flowmeter BGN. Device Description
Variable-Area Flowmeter BGN Device Description Contents 1 IDENTIFICATION... 4 1.1 Supplier/manufacturer... 4 1.2 Product type... 4 1.3 Product name... 4 1.4 Issue date... 4 1.5 Version no... 4 2 APPLICATIONS...
More informationTechnical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.
Technical Data. Flow Meter. Tel. +43/7262/61179-0 4311 Schwertberg, Poneggenstr. 5 Austria/Europe info@praher-valves.com Fax +43/7262/61203 Float-type flow meter Float-type flow meter DN Inches da Measuring
More informationOrifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam
Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by
More informationLevel switches Series LC40 Float level switch for liquids
Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the
More informationAbsolute pressure gauge with diaphragm
Absolute pressure gauge with diaphragm and switch function,type series BF2 Features Absolute pressure gauge with diaphragm and switch function Nominal ranges 0 60 mbar abs to 0 2500 mbar abs With integrated
More informationKM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation
Flow Monitor & Flow Indicator KM-165, KM-185, KM-200 OVERVIEW Operation Float measuring principle Application Cooling systems and cooling circuits Mechanical engineering Pharmaceutical industry Chemical
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationVA 40. Variable-area flowmeter. For explosion protected devices please refer to Supplementary Installation an Operating Instructions:
KROHNE 01/2005 7.02266.22.00 GR Installation and Operating Instructions VA 40 Variable-area flowmeter For explosion protected devices please refer to Supplementary Installation an Operating Instructions:
More informationGeneral Specifications
General Specifications Model RAGG Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in
More informationFlowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.
Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationVariable-Area Flowmeter for Horizontal and Vertical Installation BGF. Device Description
Variable-Area Flowmeter for Horizontal and Vertical Installation BGF Device Description Contents 1 Identification...4 1.1 Supplier/manufacturer...4 1.2 Product type...4 1.3 Product name...4 1.4 Issue date...4
More informationFlowmeter F I Gardex. Connection and installation instructions. Application. Benefits. Design and mode of operation
The baffle plate (b) causes a back-pressure in the medium, and the balance beam (c) is deflected. This movement is transmitted via the beam to the indicator mechanism (e) using a bellows bushing (d). gear
More informationFlowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing
Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in TrogamidT, suitable for inert media, and polysulfone, suitable for corrosive*
More informationLevel switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description
edit. II 2015/ page 1 Level switches (two-term level controllers) ERH-xx-04,-06,-07,6,6.1 Description The limit level signalling or two-term liquid level control in the open or closed pressure tanks. The
More informationSITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview
Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3
More informationFlowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885
Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in TrogamidT, suitable for inert media, and, suitable for corrosive* media
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationFlow switches Series AD/VH
Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,
More informationK - Flow Meter with Float
K - Flow Meter with Float Doc. no.: 18, en_cat_k, 12/2014, rev. 1 Application All-metal flow meters with float type K are used for signaling and measuring of instant flow, flowed volume of liquid and fluent
More informationFlow Measurement SITRANS F C
Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis
More informationBürkert Supplement program
ürkert Supplement program Subject to change Design changes can lead to changes in pricing Technical Specifications The technical data in the ordering tables have minimum specifications. or complete information
More informationSITRANS F C. Flow sensor MC2 4/193. Overview
Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,
More informationOperating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationGRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids
GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration
More informationRotameter flowrate metering equipment F VA 250
Assembly and mode of operation The operates according to the principle of flotation, as do other devices within this range: The flowing measuring substance raises the conical rotameter in the measuring
More informationFlow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en
/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationSITRANS F flowmeters SITRANS F I. Intra/Prima flap flowmeter. 4/284 Siemens FI
Intra flap flowmeter for transparent liquids Prima flap flowmeter for opaque liquids pplication The flap flowmeter is used to check and display the flow of liquids in closed pipelines. The device can be
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationLevel Measurement based on Archimedes Principle. Device Description
Level Measurement based on Archimedes Principle BA Device Description Contents 1 IDENTIFICATION...4 1.1 Supplier/manufacturer...4 1.2 Product type...4 1.3 Product name...4 1.4 Issue date...4 1.5 Version
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationFunction. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4
Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More informationMagnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)
Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications
More informationSITRANS F flowmeters SITRANS F C
SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationV-100 product information. Variable area flowmeters for gases and liquids
V-100 product information Variable area flowmeters for gases and liquids MyScale Air mm ALU Wide-ranging and modular: Variable area flowmeters V-100 Highly modular and adaptable for almost any requirement:
More informationRHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min
RHM 160 - The world s largest Coriolis Mass Flowmeter for flow rates up to 25000 kg/min The RHM 160 can measure flow rates up to 1500 t/hr with the patented Omega shape meter technology manufactured by
More informationTechnical Data Sheet
Technical Data Sheet Type 52 2/2-way solenoid valve NC - Valve normally closed (as standard) NO - Valve normally open (as option) Direct operated piston design valve. No differential pressure is necessary
More informationPressure transducer DMU 01K Compact version
Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,
More informationTWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B
Resistance Thermometers according to DIN Ignition Protection Exia measuring monitoring analysing TWL-Exia O O Measuring range: -...+600 C OO Pt 100-sensor class A respectively class B OO Output: resistance
More informationVariable-Area Flowmeter BGN. Installation and Operating Instructions
Variable-Area Flowmeter BGN Installation and Operating Instructions Contents 1 IDENTIFICATION... 4 1.1 Supplier/manufacturer... 4 1.2 Product type... 4 1.3 Product name... 4 1.4 Issue date... 4 1.5 Version
More informationPressure gauge in stainless steel version. Suitable for aggressive media and environments. Aluminium, white with black lettering
Ed.17.01 Application in stainless steel version. Suitable for aggressive media and environments Design EN 837-1 Series 2840 WIKA model 232.50 Case size Nominal size dim 100 mm Accuracy Class 1,0% Case
More informationDifferential Pressure and Flow meters Accessories for the Media Series
Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the
More information/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic
Variable Area Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in PA transparent or Polysulphone suitable for inert or corrosive*
More informationPlastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology
Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,
More informationFlowmeter DFM
Flowmeter DFM 165 50 Nominal size DN 10-65 Nominal size /8 2 1/2 Nominal pressure PN 10 bar Features Measuring range to 50,000 l/h suitable for a wide range of applications for gaseous medium types, water,
More informationARBO. ARBO Magnetic drive pumps. Pompen en Filters b.v. Product group 2.2
ARBO Pompen en Filters b.v. ARBO Magnetic drive pumps Product group 2.2 Product group 2.2 MagPro Working principle Magnetic drive pumps are Seal-less. The driving torque is transmitted by a permanent magnetic
More informationElectromechanical Level Control
Electromechanical Level Control Catalog 9034CT9701R2/08 08 Class 9036, 9037, and 9038 and Class 9049 Accessories CONTENTS Description..............................................Page Selection Guide..............................................
More informationVisual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page
Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Pipe Operating Operating Page O.D. x s Pressure Temperature Plastic thread 10 25670 PVDF 63.0 x 3.6 2.5-10 thread max. 140 C 61 Plastic
More informationV-Flow Line product information. Variable area flowmeters and high-precision control valves for gases and liquids
V-Flow Line product information Variable area flowmeters and high-precision control valves for gases and liquids Suitable devices for your flow application: The V-Flow Line of Vögtlin Instruments AG Variable
More informationVariable-Area Flow Meter for Horizontal and Vertical Installation BGF. Installation and Operating Instructions
Variable-Area Flow Meter for Horizontal and Vertical Installation BGF Installation and Operating Instructions Contents 1 Introduction... 4 2 Identification... 4 2.1 Supplier/manufacturer... 4 2.2 Product
More informationDifferential pressure gauge with diaphragm
Differential pressure gauge with diaphragm and switch function,type series BG2 Features Differential pressure gauge with diaphragm and switch function Nominal range -40...0 mbar to -1...24 bar, 0 40 mbar
More informationGeneral Specifications
General Specifications Model RAGK Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. This float is mounted in
More information2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm
/ or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationFlow. Oval Wheel Flowmeter Model DOE
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DOE Measuring range: 0.5 36 l/h und 1 40 l/min Viscosity range: 1 1000 cp Accuracy: ±1% of reading Material: stainless
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationAngle Seat Globe Valve, Metal
Angle Seat Globe Valve, Metal Construction The GEMÜ pneumatically operated /-way valve has a robust low maintenance aluminium actuator. The valve spindle is sealed by a self-adjusting gland packing providing
More informationMidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin
MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More information* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas
09005886 DB_EN_MA15_ATEX Rev. ST4-D 03/18 *09005886* Data sheet MA15F... A/B/C/D Diaphragm manometer for explosive areas Gas explosion protection zone 1 and 2, gases and vapours Dust explosion protection
More informationRHM Coriolis Mass Flowmeter for high Flow Applications
RHM 100 - Coriolis Mass Flowmeter for high Flow Applications The RHM 100 can measure up to 720 t/hr with the superior and patended Omega shape meter technology manufactured by rheonik, the mass flowmeter
More informationCoriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter
Coriolis Flowmeters Coriolis Flowmeters KCM C-flow series Coriolis mass flowmeter The coriolis mass flow meters measure simultaneously mass flow, volume flow, temperature and density and consequently can
More informationSITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More informationKDG/KDF - Flow Meter and Flow Switch
Integral Flow Control Valve Easy to Read Scale Brass, SS, or PVDF Process Connections Direct Reading Scales for Water and Air Compact Economical Design Optional Panel Mounting Kit Optional Flow Switch
More informationProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction
ProFlow N142 P R O D U C T B U L L E T I N Vane Meters Special versions This brochure comprises only VAF Instruments standard delivery program. Special flowmeter variants can be offered as tailor-made
More informationSATRON VT Pressure Transmitter
SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring
More informationInstallation and Operating Instructions. Variable area flow meter RA 65 / FA 65
Installation and Operating Instructions Variable area flow meter 2 Contents 1. Foreword...3 2. Safety...3 2.1. Symbol and meaning...3 2.2. General safety directions and exemption from liability...3 2.3.
More informationMagnetic Float Switch. Series 137. Level Measurement & Control Solutions
Level Measurement & Control olutions Magnetic Float witch eries 37 OPERATING PRINCIPLE: FEATURE: Modular construction.... witch module. 2. Flange module. 3. Float module. This means it gives flexibility
More information2 way ball valve M1 with pneumatic actuator
Praher Plastics Austria GmbH DB/EN/DEEN/14/03/335 Subject to change without prior notice!! General: Valve body: Sealing material: Ball seating joint: Dimensions: PVC-U EPDM / FPM PTFE DN10 DN50 d16 d63
More informationSIHI LPH-X - Liquid Ring Vacuum Pump Two Stage
- Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction
More informationOld documentation - Only for your information! Product is not available any more!
GasBloc Solenoid valve Single or multiple actuator GB 0 D0.1 Printed in Germany Edition 0.10 Nr. 0 9 1 6 Technical description The GB 0 gas valve family comprises 1, or solenoid valves as single or multiple
More informationMagnetic float switch For vertical installation Model FLS
Level measurement Magnetic float switch For vertical installation Model FLS KSR data sheet FLS for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and level
More informationVariable V Area Flowmeter Rotameter The Original
Variable V Area Flowmeter Rotameter The Original precise measurement of liquids and gases robust and universal proven device with an installed base of more than 500,000 worldwide a wide product range many
More informationMicro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
More informationSample gas pumps P2.x ATEX
Gas Analysis Sample gas pumps P2.x ATEX Even in explosive systems in the chemical industry, petrochemistry or biochemistry, gas analysis is key for safe operation. Many of the analysis processes used in
More informationGeneral Specifications
eneral Specifications Model RAH Rotameter S 01R01B05-00E-E This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting
More informationOPTIFLUX 6000 Technical Datasheet
OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical
More informationSITRANS F M flow sensors 711/A and 711/911E
s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law
More information2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50
2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be
More informationNIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions
NIVOMAG MAGNETIC LEVEL SWITCHES FEATURES Magnetic coupling between the switch and the float Operation w/o external power supply Side or top mounted versions Underwater housing Fixed or variable hysteresis
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For
More informationFlow-Alert Flow Switches (Micro Switch)
Flow-Alert Flow witches (Micro witch) Automatically signals alarm if flow is too high or too low Automatically opens or closes electrical circuits Triggers warning lights, buzzers and other devices huts