2009 ROHN PRODUCTS LLC
|
|
- Cleopatra Malone
- 5 years ago
- Views:
Transcription
1 2009 ROHN PRODUCTS LLC
2 G U Y E D T O W E R S S T A N D A R D 2 5 G G U Y E D T O W E R GENERAL USE The is available in the standard 0 section length and a 7 length which is UPS shippable. The uses double bolted joints, proven to be the best method of joining tower sections for sturdiness and dependability. As a guyed structure, the can rise to a maximum of 90. FEATURES Completely hot-dip galvanized after fabrication Accessories for are the same as the 20G and are completely interchangeable Built on 2 /2 equilateral triangle design High strength tubular legs joined by Zig-Zag cross members Each 0 section contains all required nuts and bolts inside one leg Extra heavy-duty /4 steel tubing side rails Continuous solid steel rod bracing QUICK REFERENCE PARTS & ACCESSORIES PAGE 4 INFORMATION PAGE 7 FOUNDATION INFORMATION PAGE 8 Phone (309) Fax (309) The Industry Standard
3 G U Y E D T O W E R S S T A N D A R D 2 5 G G U Y E D T O W E R S E C T I O N S G U Y E D T O W E R S 93/4 6/2 /4 8/4 2 O.D..87 I.D..25 O.D. (6 GA. wall) 5/6 O.D. Bracing.25 O.D. (6 GA. wall) /6 O.D. Bracing STANDARD TOP SECTION 25AG 2 /2 STANDARD SECTION - 0 Section 7-7 Section The 7 Section is UPS shippable. Additional top sections are shown on page 4. Phone (309) Fax (309) The Industry Standard 2
4 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F EPA (SQ. FT.) For Exposure B, Revision G EHS 5.8 P/N 90R EPA (SQ. FT.) For Exposure C, Revision G EPA (SQ. FT.), Revision F P/N 90R050 Tower Model Tower Height Windspeed (Rev. G) ROHN Tower EPA= Effective Projected Area Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance. DESIGN NOTES:. Tower designs are in accordance with ANSI/TIA-222-F-996 and ANSI/TIA-222-G-2005, Class I Structures. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two /2 diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ). 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES:. Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations. 2. Standard guys provided with each standard tower include an additional 6% length. 3. Anchor grounding (AGKGGX) and base grounding (BGK3GGX) with the tower material. 4. Installation information and a safety package (P/N: ACWS) are included with each tower. FOR FOUNDATION INFORMATION, PLEASE SEE PAGE 8. 3 Phone (309) Fax (309) The Industry Standard
5 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 22.6 OR /6 EHS 32 P/N: 90R /6EHS BG242 5/6THH 5/8TBE&J TBSAFETY GAR30 AGKGGX BGK3GGX CPC.5/ CB 3/4 x 2PP 40 ROHN Part No: 90R TOWER 2.4 OR /6 EHS 40 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 50 ROHN Part No: 90R TOWER 20.3 OR /6 EHS 48 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 60 ROHN Part No: 90R TOWER 9.4 OR /6 EHS 56 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 70 ROHN Part No: 90R TOWER 8.6 OR /6 EHS 64 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 80 ROHN Part No: 90R080 Phone (309) Fax (309) The Industry Standard 4
6 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 8.0 OR /6 EHS 8 3 CB 3/6EHS BG242 5/6THH 5/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R090 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 7.5 OR /6 EHS 80 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 00 ROHN Part No: 2590R TOWER 7.0 OR /6 EHS 0 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R0 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 6.6 OR /6 EHS 96 P/N: 90R20 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 20 ROHN Part No: 90R TOWER 6.2 OR /6 EHS 04 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 30 ROHN Part No: 90R30 5 Phone (309) Fax (309) The Industry Standard
7 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 5.9 OR /6 EHS 2 P/N: 90R /6EHS BG242 5/6THH 5/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 90R TOWER 5.5 OR /6 EHS 4 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R50 GAC305 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 5.3 OR /6 EHS 5 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R60 GAC305 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 5.0 OR /6 EHS 6 5 3/6EHS BG242 5/6THH 3/8TBE&E CB TBSAFETY ROHN Part No: 90R P/N: 90R70 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP TOWER 4.8 OR /6 EHS 7 5 3/6EHS BG242 5/6THH 3/8TBE&E CB TBSAFETY ROHN Part No: 90R P/N: 90R80 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 6
8 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 4.5 OR /6 EHS 8 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R90 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP 7 Phone (309) Fax (309) The Industry Standard
9 G U Y E D T O W E R S 0 M P H R E V. G, 9 0 M P H R E V. F TOWER 3.4 OR /6 EHS 3 CB 3/6EHS BG242 5/6THH 5/8TBE&J TBSAFETY ROHN Part No: 0R P/N: 0R040 GAR30 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 2.6 OR /6 EHS 40 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 50 ROHN Part No: 0R TOWER.9 OR /6 EHS 48 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 60 ROHN Part No: 0R TOWER.3 OR /6 EHS 6 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R070 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 0.9 OR /6 EHS 7 3 CB 3/6 EHS BG242 5/6 THH 3/8 TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R080 AGKGGX BGK3GGX CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 8
10 G U Y E D T O W E R S TOWER 0.5 OR /6 EHS 72 P/N: 0R090 0 M P H R E V. G, 9 0 M P H R E V. F 8 3 3/6EHS BG242 5/6THH 5/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 90 ROHN Part No: 0R TOWER 0.2 OR /6 EHS 9 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R00 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.9 OR /6 EHS 0 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R0 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.7 OR /6 EHS 96 P/N: 0R20 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 20 ROHN Part No: 0R TOWER 9.3 OR /6 EHS 04 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 30 ROHN Part No: 0R30 9 Phone (309) Fax (309) The Industry Standard
11 G U Y E D T O W E R S TOWER 9.2 OR /6 EHS 2 P/N: 0R40 0 M P H R E V. G, 9 0 M P H R E V. F 3 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 0R TOWER 9.0 OR /6 EHS 4 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R50 GAC3455TOP AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.8 OR /6 EHS 5 5 CB 3/6EHS BG242 5/6THH /2TBE&J TBSAFETY ROHN Part No: 0R P/N: 0R60 GAC3455TOP AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.7 OR /6 EHS P/N: 0R BASE CB2 3/6EHS BG242 5/6THH 3/8TBE&E /2TBE&J TBSAFETY GAC305 GAC3455TOP AGKGGX BGK3GGX CPC.5/ INNER ANCHOR OUTER ANCHOR 3/4x2PP 70 ROHN All par ts shown in table are included when ordering Part No: 0R TOWER 8.6 OR /6 EHS P/N: 0R BASE CB2 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC3455TOP AGKGGX BGK3GGX CPC.5/ INNER ANCHOR OUTER ANCHOR 3/4x2PP 80 ROHN All par ts shown in table are included when ordering Part No: 0R80 Phone (309) Fax (309) The Industry Standard 0
12 G U Y E D T O W E R S G U Y E D T O W E R S TOWER 8.5 OR /6 EHS P/N: 0R90 0 M P H R E V. G, 9 0 M P H R E V. F 8 6 3/6EHS BG242 5/6THH 3/8TBE&E GAC3455TOP AGKGGX BGK3GGX BASE CB2 /2TBE&J 2 CPC.5/.75 6 INNER ANCHOR OUTER ANCHOR TBSAFETY 6 3/4x2PP 90 ROHN All par ts shown in table are included when ordering Part No: 0R90 Phone (309) Fax (309) The Industry Standard
13 G U Y E D T O W E R S TOWER 0.8 OR /6 EHS 32 P/N: 30R M P H R E V. G, 0 M P H R E V. F 3 3/6EHS BG242 5/6THH 5/8TBE&J TBSAFETY GAR30 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 30R TOWER 0. OR /6 EHS 4 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R050 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.7 OR /6 EHS 5 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R060 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.2 OR /6 EHS 6 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R070 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.9 OR /6 EHS 7 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R080 AGKGGX BGK3GGX CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 2
14 G U Y E D T O W E R S TOWER 8.6 OR /6 EHS 72 P/N: 30R M P H R E V. G, 0 M P H R E V. F 8 3 3/6EHS BG242 5/6THH 3/8TBE&E AGKGGX BGK3GGX CPC.5/ CB TBSAFETY 3/4x2PP 90 ROHN Part No: 30R TOWER 8.4 OR /6 EHS 80 P/N: 30R /6EHS BG242 5/6THH 3/8TBE&E AGKGGX BGK3GGX CPC.5/ CB TBSAFETY 3/4x2PP 00 ROHN Part No: 30R00 3 Phone (309) Fax (309) The Industry Standard
15 G U Y E D T O W E R S P A R T S & A C C E S S O R I E S O.D..38 I.D..25 N.P.T O.D I.D / O.D I.D. - /4 8-3/6-4 /4 TOP SECTION 25AG TOP SECTION 25AG2 TOP SECTION 25AG3 TOP SECTION 25AG4 8-3/2-5/ O.D I.D. 3 4 SHORT BASE SB TOP SECTION 25AG5 BEARING PLATE BPL LONG LEGS PROVIDE EXTRA EARANCE FOR INSTALLATION OF EQUIPMENT. BOLTS TO TOP OF STANDARD SECTION. DRILLED TO ACCEPT TB3 OR TB4 THRUST BEARING. ASSEMBLY PLATE / TOP BEACON PLATE APL FOR MOUNTING BEACON. BOLTS TO TOP OF STANDARD SECTION. 5 SHORT BASE SB5 3 4 HINGED SHORT BASE SBH HINGED TO BOTTOM. THESE BASE SECTIONS FOR EMBEDMENT IN CONCRETE. CONCRETE BASE PLATE BPC* FOR USE WITH PIER PIN EMBEDDED IN CONCRETE. PIER PIN 3/4x2PP MUST BE ORDERED SEPARATELY. HINGED BASE PLATE BPH* BOLTS TO CONCRETE. HINGED TO ALLOW TOWER TO BE ROTATED UP FROM BASE DURING INSTALLATION. BASE BOLTS /2x2BB MUST BE ORDERED SEPARATELY. SINGLE DRIVE-IN BASE SDB TO BE DRIVEN DIRECTLY INTO GROUND. TAPERED BASE 25TGA* CAN BE USED WITH RACAL DECCA A497L BASE INSULATOR OR WITH 3/4x2PP. * TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING. Phone (309) Fax (309) The Industry Standard 4
16 G U Y E D T O W E R S P A R T S & A C C E S S O R I E S PEAK ROOF MOUNT PR* ADJUSTABLE HINGED FEET CONFORM TO NEARLY ANY ROOF PITCH. BOLTS TO ROOF SURFACE. FLAT ROOF MOUNT FR* BOLTS DIRECTLY TO FLAT ROOF SURFACE. SIDE ARM MOUNT UHF FOR UHF & FM ANTENNAS. SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3 LONG, 2 - /4 O.D. TOP MOUNT 25TDMKD - NO PIPE 25TDM2S3KD - 2 X 7 PIPE 25TDM25S3KD - 2 /2 X 7 PIPE 25TDM3S3KD - 3 X 7 PIPE 25TDM35S3KD - 3 /2 X 7 PIPE TOP PLATE INUDES BUILT IN GUY LUGS. BOLTS TO SWAGED TOP OF STANDARD SECTION. LOWER PLATE CONNECTS WITH U-BOLTS. SET SCREWS SECURE MOUNTING PIPE. FACE MOUNT DM2 MOUNTING PIPE IS 5 LONG, 2 STD. ADJUSTABLE HOUSE BRACKET HB25AG 0-5 HB25BG 0-24 HB25CG 0-36 HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 8-36 FROM WALL. UNIVERSAL EAVE BRACKET EB25 HINGED ALLOWS TOWER LEG AMPS TO REMAIN PERPENDICULAR TO GROUND WHILE BOLT DOWN SUPPORTS ROTATE TO LAY FLAT ALONG PITCHED ROOF OR EAVE. GUY BRACKET GAD MOUNTS TO ANY TOWER AT ANY HORIZONTAL BRACE. TORQUE BARS TB25D OPTIONAL, FOR USE WITH GAD (NOT SHOWN). ANTI-IMB PANELS 25A3 THREE ANTI-IMB PANELS TO BOLT TO EXISTING STANDARD TOWER SECTION. TORQUE ARM STABILIZER ASSEMBLY TA25 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER. * TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING. 5 Phone (309) Fax (309) The Industry Standard
17 GUYED TOWERS PA R T S & A CC E S S O R I E S 90º JOINTS 2590MM - BOTH ENDS SWAGED JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. 90º JOINTS 2590FF - BOTH ENDS OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. 90º JOINTS 2590FM - ONE END SWAGED, ONE OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. ACCESSORY SHELF AS FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS. RP BEARING/ACCESSORY SHELF BAS RP CM DRILLING TO ACCEPT THRUST BEARING ON TOP PLATE. ACCESSORY SHELF DRILLED FOR MOUNTING MANY POPULAR ROTORS. ROTOR POST SAFETY RING SR245 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED. THRUST BEARING TB3 - SUPPORTS UP TO 2 O.D. MAST. TB4 - SUPPORTS UP TO 3 O.D. MAST. MOUNTS TO BAS OR BLP. WORK PLATFORM WP SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED. TOWER BUSHING TB50 - -/4 I.D. X 2 O.D. TB75 - -/2 I.D. X 2 O.D. FOR USE ON 25AG TOP SECTION REFER TO PAGE 2. ERECTION FIXTURE EF /2 SHEAVE WITH 3/8 I.D. GROOVE. NOTE: ERECTION FIXTURES ARE FOR LIFTING ONE 0 SECTION AT A TIME AND ARE NOT INTENDED FOR THE LIFTING OF PERSONNEL. Phone (309) Fax (309) The Industry Standard 6
18 GUYED TOWERS G R O U N D I N G I N F O R M AT I O N 2 IN. 84 IN..63 IN..63 IN IN. IN. 2 IN. 84 IN. GAR30 ( 7,330 LBS. ALLOWABLE LOAD)* 5.25 IN. ( 7,330 LBS. ALLOWABLE LOAD)* 8 IN. 84 IN..63 IN. 2 IN IN..38 IN. GAC305 ( 7,330 LBS. ALLOWABLE LOAD)* 2 IN. 2.5 IN. P/N STAMPED HERE.75 IN. 2 IN. GAC3455TOP ( 7,670 LBS. ALLOWABLE LOAD)* ANCHOR RODS Notes:. and GAC305 rods are supplied with type EP25343 and EP25345 equalizer plates - as in type GAR30 rod. 2. Part number suffixes 3,5 and 55 denotes 3 or 5 holes in equalizer plates. 3. Type EE equalizer plates are supplied in pairs for eye and eye turnbuckles. 4. Type EJ equalizer plates are used with eye and jaw turnbuckles. * INUDES INCREASE IN ALLOWABLE STRESSES. BASE ANCHOR * Clamp is not included in grounding kit. It must be ordered as a separate item. TINNED BARE COPPER WIRE (NO. 4 MAX) 6.00 IN. MIN. (52mm) ATTACH TO LEG WITH SUPPLIED LEG AMP AMP NO. : GUY WIRE SIZE* P/N CPC.5/.75: 3/6 IN. - /2 IN. TINNED BARE COPPER WIRE (NO. 4 MAX) GROUND ROD AMP 0 FT. (2.483M) COPPER AD GROUND ROD GROUND ROD AMP 6.00 IN.MIN. (52mm) 0 FT. (2.483M) COPPER AD GROUND ROD 7 Phone (309) Fax (309) The Industry Standard
19 GUYED TOWERS STANDARD FOUNDATIONS Pier Pin Pier Pin 4 IN. Projection 4 IN. Projection 6 IN. 3 IN. Maximum No. 3 Circular ties, 3 in. on centers with 6 in. laps (8) No. 7 vertical bars equally spaced on a 2in. diameter circular cage 4 FT. 6 IN. No. 3 Circular ties, 3 in. on centers with 6 in. laps (0) No. 7 vertical bars equally spaced on a 27in. diameter circular cage 4 FT. 6 IN. ELEVATION VIEW ELEVATION VIEW 2 FT. 6 IN. 3 FT. 3 FT. 2 FT. 6 IN. 6 IN. 3 IN. Maximum Alternate Square Pier Alternate Square Pier PLAN VIEW PLAN VIEW CB2 CB Concrete Volume =.2 CU. YDS. Concrete Volume = 0.8 CU. YDS. STANDARD ANCHOR BLOCKS Centerline of anchor Ground line Ground line 40º 3 FT. Centerline of anchor Ground line Ground line 42º #5 Horizontal bars equally spaced at 0 IN. O-C all around #6 Horizontal bars equally spaced at 0.5 IN. O-C all around 4 FT. #3 Stirrups equally spaced 2 IN. O-C #3 Stirrups equally spaced 2 IN. O-C FT. FT. 6 IN. 3 FT. 4 FT. 4 FT. 6 FT. ELEVATION VIEW PROFILE VIEW ELEVATION VIEW PROFILE VIEW Concrete Volume 0.4 CU. YDS. per block.3 CU. YDS. total for 3 Concrete Volume.3 CU. YDS. per block 4.0 CU. YDS. total for 3 NOTE: 3 Minimum cover required on all reinforcing bars. Phone (309) Fax (309) The Industry Standard 8
20 2009 ROHN PRODUCTS LLC
STANDARD 25G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard
G GUYED TOWERS 25G STANDARD 25G GUYED TOWER ROHN 25G The first. The original. includes REV. F & REV. G 25G GENERAL USE The 25G is available in the standard 0 section length and a 7 length which is UPS
More informationSTANDARD 80 SERIES GUYED TOWER GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard
G GUYED TOWERS - 80 STANDARD 80 SERIES GUYED TOWER 80 SERIES GENERAL USE The ROHN Model 80 Guyed Tower is designed with variable sized legs and braces to allow construction to heights of 1000. This tower
More informationEFFECTIVE WIND VELOCITY FORMULA SHEET
RM ROOF MOUNTS EFFECTIVE WIND VELOCITY FORMULA SHEET ROHN recommends a minimum mph Effective Wind be used for determining ballast requirements. Refer to page 2 for ballast requirements and general notes.
More informationEFFECTIVE WIND VELOCITY FORMULA SHEET
ROOF MOUNTS EFFECTIVE WIND VELOCITY FOULA SHEET ROHN recommends a minimum mph Effective Wind be used for determining ballast requirements. V = C1 C2 V e V e = Effective Wind at centerline of antenna for
More informationRound: 95/53/37 Flat: 57/31/22 Round: 77/55/28 Flat: 46/33/17
Tower Kits Tower Height: 40' 50' 60' 70' Part Number 4.618.G000.040 4.618.G000.050 4.618.G000.060 4.618.G000.070 List Price $4026.00 $4425.00 $4825.00 $5224.00 Round: 100/54/38 Flat: 60/32/22 Round: 80/60/30
More informationPRODUCT NAME ORDER # PAGE # ANTENNAS
PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband
More informationINTRODUCTION. Sincerely, Dan Ianello, PE President. Toll Free: NELLO Fax:
INTRODUCTION Nello Corporation specializes in the Communications Support Infrastructure market. We have a strategy of providing innovative and cost effective products to an industry that relies on quality,
More informationTable of Contents. Kit Maximum Examples Index by Kit Number Terms and Conditions...Inside Back Cover
Table of Contents Antenna Mounts Light Standoff Mounts...2 Medium Standoff Mounts...4 Heavy Standoff Mounts...6 Fixed Crossover Assemblies...8 Universal Crossover Assemblies...8 Hybrid Crossover Assemblies...9
More informationKROFTMAN CONTAINER SHELTER TC812
KROFTMAN CONTAINER SHELTER CONTENT FRAME P82-FR 82-0 82-02 82-03 82-0 82-05 82-06 82-07 parts list frame part numbers main frame base plan, frame plan available hight inside detail 0 detail 02, 03 Roof
More informationQuality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS
Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with
More informationInstallation Instructions
Description Instructions given in this bulletin apply to either a standard, unshielded or high-performance, shielded antenna. The antenna consists of a two-piece reflector, braced by a back structure;
More informationWIDE-CORRUGATION FARM GRAIN BINS
SM WIDE-CORRUGATION FARM GRAIN BINS B R O C K G R A I N B I N S B rock Grain Systems has a world-wide reputation for providing reliable on-farm storage that allows farmers to market their grain when they
More informationLSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders
C. Stairs & Ladders 1. General Requirements a. A stairway or ladder must be provided at all worker points of access where there is a break in elevation of 19 inches (48 cm) or more and no ramp, runway,
More informationLMS 106 CR MODEL MOBILE TOWER
LMS 106 CR MODEL MOBILE TOWER 106 TALL, 6 EA SECTIONS LEGS ASTM A500-07, A53-12, GRADE B, US CARBON STEEL Lifetime Warranty TILT BASE ASSEMBLY INTEGRATED INTO TRAILER. Lifetime Warranty 3 SECTOR ANTENNA
More informationPecco SK 225 TOWER CRANE. 106 ft (32.3m) 19,900 lbs kg. Hook Heights. Sections I
11 x S35 = 212'-11" (64.9m) 11 x S35 = 212'-11" (64.9m) Pecco SK 225 TOER CRANE 200 ft (61.0m) 7,100 lbs 3 200 kg 181 ft (55.2m) 8,800 lbs 4 000 kg 163 ft (49.7m) 10,600 lbs 4 800 kg 144 ft (43.9m) 12,800
More informationSentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions
WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the
More informationHi-Tech specially designed components allow for fast and easy assembly.
OPEN SHELVING MEDIUM, HEAVY AND EXTRA HEAVY-DUTY HI-TECH STEEL SHELVING Open Starter Units Include: Two beaded front posts, two angle back posts, one pair of back sway braces, two pair of side sway braces
More informationTechnical Math 2 Lab 3: Garage Door Spring 2018
Name: Name: Name: Name: As you may have determined the problem is a broken spring (clearly shown on the left in the picture below) which needs to be replaced. I. Garage Door Basics: Common residential
More informationLMS 120 XHD MODEL MOBILE TOWER
LMS 120 XHD MODEL MOBILE TOWER MOBILE TOWER 120 TALL, 6 EA SECTION LEGS ASTM A500-07, A53-12, GRADE B, US CARBON STEEL Lifetime Warranty TILT BASE ASSEMBLY INTEGRATED INTO TRAILER. Lifetime Warranty 3
More informationSafety Ladders: Hot Dip Galvanized/Stainless Steel
Y-Spar Guide-rail profile: 50 x 32 mm. Comes with joint plate. Mounting brackets extra to order. Recommended mounting distance 1400 mm - max. 1680 mm. Installation of bracket to ladder is carried out through
More informationRush and setup xstage S4
Rush and setup xstage S4 S4 is an ideal option for use during the biggest events, thanks to its unique adjustability from 1 m (39.37") up to 2.5 m (98.4") (floor height). Very large adjustability range,
More informationDetroit Speed, Inc. Mini Tubs Camaro/Firebird P/N:
Detroit Speed, Inc. Mini Tubs 1967-1969 Camaro/Firebird P/N: 040401 The Detroit Speed Mini-Tubs are inner wheel housings designed to accommodate a wider wheel and tire package. They are engineered for
More informationANTENNA SUPPORT STRUCTURES
14.1 Rooftop Ballast Frame for Wireless Antennas General Description Non-penetrating Rooftop Ballast Frames enable installation of wireless panel antennas for a sector. The Frames are secured using concrete-block
More informationTITAN Motor Truck Scale
S C A L E S Instruction Manual TITAN Motor Truck Scale Model: 00 Series FAIRBANKS 00 by Fairbanks Scales Inc. All rights reserved 0 Revision # 0/0 Amendment Record Titan 00 Series Motor Truck Scale 0 Manufactured
More informationLADDER SAFETY PROGRAM
All ladders at Craven Community College must be constructed and used in accordance with OSHA regulations and ANSI standards. All commercially manufactured ladders must have a label indicating it meets
More informationANTENNA PARTS CATALOG
ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net Call to order: (815) 244-3500 SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine Screw
More informationProduct Information. December 1, The Cable Connection 52 Heppner Drive Carson City, NV 89706
Product Information December 1, 2016 The Cable Connection 52 Heppner Drive Carson City, NV 89706 800.851.2961 775.885.1443 Fax: 775.885.2734 E-mail: info@ultra-tec.com www.ultra-tec.com Summary of Cable
More informationDetroit Speed, Inc. Mini Tubs Camaro/Firebird P/N:
Detroit Speed, Inc. Mini Tubs 1967-1969 Camaro/Firebird P/N: 040401 The Detroit Speed Mini-Tubs are inner wheel housings designed to accommodate a wider wheel and tire package. They are engineered for
More informationCommercial Bins/Silos
Commercial Bins/Silos Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, Grain Systems offers the strongest and heaviest gauge storage tanks
More informationINSTRUCTION MANUAL L WIND CONE
Cooper Industries DOCUMENT September 29, 2009 Revision B Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 Title: INSTRUCTION
More informationINFORMATIVE MATERIAL 5 QUICK LASHING GUIDE. Cargo securing on CTUs for transports on Road, Combined Rail and in Sea Area A, B & C SEA AREAS
Page 65 INFORMATIVE MATERIAL 5 QUICK LASHING GUIDE Cargo securing on CTUs for transports on Road, Combined Rail and in Sea Area A, B & C SEA AREAS A B C H s 8 m 8 m < H s 12 m H s > 12 m Baltic Sea (incl.
More informationStyle 233-L & 234-L Rubber Joints
Style 33-L & 3-L Rubber Joints Style 33-L Rubber s are designed for piping systems that experience large lateral offsets due to settlement. The Style 33-L is a low profile triple arch design with a built-in
More informationMaintenance Information
16606022 Edition 3 May 2014 Air Drill 728 Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these potentially
More informationA. This Section includes the following types of sectional overhead doors:
SECTION 08361 - SECTIONAL OVERHEAD DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationCommercial Hopper Tanks (CHT)
Commercial Hopper Tanks (CHT) Total Value. Total Systems. NCHT & FCHT Series The right tank for the right job. Commercial hopper tanks are typically used in applications where routine clean out is required,
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationWhen buying Crosby you re buying more than product, you re buying Quality.
From a 2 ton capacity snatch to a 6000 metric ton capacity crane, McKissick can make a McKissick s major involvement in the block McKissick When buying Crosby you re buying more than product, you re buying
More informationCASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002
CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002 Case Study compiled by: Rhonda Gatzke, Member GEO 11/2002 Some Some of of the the project project participants: participants: Metro Metro
More informationPecco SK TOWER CRANE. FREESTANDING (stationary) Hook Heights. 200 ft (60.9m) 8,300 lbs kg. 180 ft (55.0m) 10,300 lbs kg
x S5 = '-" (6.9m) x S5 = '-" (6.9m) Pecco SK 80-0 TOER CRANE 80 ft (55.0m) 00 ft (60.9m) 0,00 lbs 700 kg 8,00 lbs 750 kg ft (.m) 6 ft (9.m),00 lbs 5 500 kg,700 lbs 6 700 kg ft (7.6m) 7,500 lbs 7 900 kg
More informationGRC. R & C Agency Trapeze Lighting
GRC R & C Agency 2013 Lighting 3 TW-001 Straight Fixture Basic, economical straight fixture. Lamp can only be adjusted downward. Max. / Dichroic TW-001A Twist Action Fixture Multi functional trapeze fixture
More informationFlexLink conveyor Series Y
FlexLink conveyor Series Y 3 Introduction New conveyor with focus on hygiene The new FlexLink hygiene conveyor was designed to meet the following requirements of special interest to the dairy, food, and
More informationBESTEEL 170 SERIES CURTAIN TRACKS
BESTEEL 170 SERIES CURTAIN TRACKS BL = Black Finish 2XX Series Track Systems have a black finish. Parts Included 170 (270) 170 BESTEEL CWANA code CORD OPERATED/MOTORIZED 171 (271) 171-R (271-R) 260 172
More informationInnovative designs to improve your bottom line.
Innovative designs to improve your bottom line. UNIQUELY DESIGNED WALLS FOR ADDITIONAL STRENGTH The flat sided (trapezoidal) configuration with built-in wind bands, offered as a standard design feature
More informationD and DL Annular Blowout Preventers
D and DL Annular Blowout Preventers In the unique design of the Cameron DL Annular BOP, closing pressure forces the operating piston and pusher plate upward to displace the solid elastomer donut and force
More information*We only delivery to Western portions of Oregon *Prices subject to change without notice
Alan's Factory Outlet Carport Prices in Oregon *We only delivery to Western portions of Oregon *Prices subject to change without notice 1-800-488-6903 www.alansfactoryoutlet.com Regular Style Carport Prices
More informationpanelclaw.com Polar Bear III for 10 Degree
panelclaw.com Polar Bear III for 10 Degree Installation Manual Document Number 9910024 Rev A March 2014 Revision History Rev ECO # Date Description of Changes Approved By 01 TBD 02-FEB-14 Initial Draft
More informationAlbuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN. Bid Tabulation Abstract
Albuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN Bid Tabulation Abstract ITEM # DESCRIPTION BRAND NAME Fabric - Smooth galvanized, 2 in. mesh, open hearth
More informationSpecifications LS-248H II. 200-Ton ( metric ton) Hydraulic Lattice Boom Crawler Crane
Specifications Hydraulic Lattice Boom Crawler Crane LS-248H II 200-Ton (181.50 metric ton) Shown with side frame auxiliary counterweights. Not to Scale General dimensions feet meters Basic boom length
More informationASSEMBLY INSTRUCTIONS
WIND GENERATOR KIT Complete Set Including All Accessories 500 Watts rated at 12,5 m/s (= 28 mph) 6 Meter (= 20 ft.) Free-Standing Tower ASSEMBLY INSTRUCTIONS Contents WIND GENERATOR KIT Complete Set Including
More informationOPERATION MANUAL 17 Crown Block Sheave Manufactured by Wireline Technologies, Inc. Serial Number
OPERATION MANUAL 17 Crown Block Sheave Manufactured by Wireline Technologies, Inc. Serial Number Introduction This manual explains the use and care of 17 Crown Block Sheaves manufactured by Wireline Technologies,
More information10 X 10 NPMM Installation
May 20, 2016 Revision E ASSEMBLY MANUAL Installation General Dynamics SATCOM Technologies 1700 Cable Drive NE Conover NC 28613 USA Phone 770-689-2040 www.gdsatcom.com 10' x 10' NPMM INSTALLATION INSTRUCTIONS
More informationTHEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES
LMS 85 HW 85 MODEL, 5 EA-21 MULTIPLE SECTIONS Lifetime Warranty, 36 X 21 SUPER HEAVY-DUTY BASE SECTION, ALL SECTIONS ASTM A500-07, A53-12, GRADE B, CARBON STEEL, SCHEDULE 40 STRUCTURAL TUBING Lifetime
More informationTHD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs
CONTROLS Division of A-T Controls, Inc. THD Series Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 In-lbs Double Acting and Spring Return Symmetric and
More informationZip Tie Domes - 3V 3/8 Assembly Manual
Zip Tie Domes - 3V 3/8 Assembly Manual Instructions for Assembling the 25 Foot 3V 3/8 Frequency Geodesic Dome Tools Needed: 8 foot Step Ladder, Wire Cutters SAFETY RULES: Do Not Climb On the Dome. It is
More informationSpring Cable Reels EXEL
Spring Cable Reels EXEL Conductix - Wampfler designs and manufactures high-performance electrification systems for mobile equipment used in heavy industries such as iron and steel, food processing, cement
More informationDIGIFLO ELECTRONIC FLOWMETER
DIGIFLO ELECTRONIC FLOWMETER PIPE FITTING INSTALLATION MANUAL SADDLE MACHINED IN-LINE BODY MOLDED IN-LINE BODY MOLDED TEE Blue-White R Industries, Ltd. F-2000 Page 2 1.0 Temperature vs. Pressure Temperature
More informationSuperTrac. Axle. Service & Maintenance. Manual
SuperTrac Axle Service & Maintenance Manual Table of Contents Page Exploded Views Section 1: General Information General Warnings Description of Axle Models Identifications Section 2: Installation Axle
More informationSentinel Field Satellite Controller
WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning
More informationPRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts...
S 1 Index PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3 GROUND and pole MOUNT SYSTEMS...5 Power Rail Module Mounting System...6 Power Rail Extrusions...7 Power Rail Commercial Extrusions...7
More informationHome Frontload Washers
Home Frontload Washers Refer to Page 3 for Model Numbers Parts FLW1536C_802849 www.alliancelaundry.com Part No. 802849R9 January 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial
More informationRIG-I-FLEX 140 SERIES CURTAIN TRACKS
RIG-I-FLEX 140 SERIES CURTAIN TRACKS Parts Included 140 RIG-I-FLEX CWANA code CORD OPERATED/MOTORIZED WALK-ALONG 140 (240) 140-R (240-R) 141 (241) 141-R (241-R) 142 (242) 142-R (242-R) STRAIGHT CURVED
More informationMATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...
153 Contents General.................................................................................................. 154 C-bracket.................................................................................................
More informationWE BELIEVE IN A
WE BELIEVE IN A COMPANY CONTENTS TECNOPALI North Europe is the largest steel lighting pole, mast and accompanying steel structure producer in the Baltics, located in Daugmale, Latvia. Tecnopali North Europe
More informationSunfire Series. Full Size Electric Convection Ovens. Parts List. Models SCO-ES-10S SCO-ES-20S. Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/15
Sunfire Series Full Size Electric Convection Ovens Parts List Models SCO-ES-0S SCO-ES-20S Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/5 Rating Plate Location Door Door Motor Motor Rating Plate,
More information2.88 OD Universal Mast Mount
Revision A January 19, 2006 ASSEMBLY MANUAL 2.88 OD Universal Mast Mount GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com 2.88 O.D. Universal
More informationStructural Support Products. Wireless Site Solutions Ordering Guide Version 2.1
Structural Support Products Wireless Site Solutions Ordering Guide Version 2.1 TOWER MOUNTS G2 Series High Capacity Sector Frames Quick-Vee Medium Capacity Sector Frames Sector Frame Reinforcement Kits
More informationSeries 2, 3, 4, & 5 Aluminum - Accessories
The following is a list of accessories and fittings that can be provided with S8 tray. For more information on these items, contact our Engineering Department. Fittings Horizontal Bends 30 Bends with 24,
More informationAppendix 4 Exploded Views & Parts Lists. 34 Generac Power Systems, Inc.
Appendix Exploded Views & Parts Lists CENTURION Home Standby Generator Enclosure - Drawing No. E 7 8 7 7 8 7 8 8 7 Generac Power Systems, Inc. Appendix Exploded Views & Parts Lists CENTURION Home Standby
More informationSITE ACCESSORIES CATALOG USA.
SITE ACCESSORIES CATALOG USA 2019 www.trylon.com Pictorial Table of Contents Page 2 Sector V-Frames Page 4 RRU Mounts Page 5 Rotatable Standoff Mounts Page 6 Light Standoff Mounts Page 8 Medium Standoff
More informationNon Penetrating Mast Mount for 2.4M Antennas
April 27, 2007 INSTALLATION MANUAL Non Penetrating Mast Mount for 2.4M Antennas GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com Non-Penetrating
More informationHarding Steel Tri-Lift
Harding Steel Tri-Lift World Class Lifts since 1968 Harding Steel Tri-Lift Density Security Economy Tri-Lift System Description System Description: The Harding Steel Tri-Lift parking system is a 4-post
More informationApplied. ATTENTION! 1200 lb WEIGHT LIMIT L-25 MINI TOWER INSTRUCTIONS REVISED: 10/24/2017 PROUDLY MADE IN THE U.S.A.
1 L-25 MINI TOWER ATTENTION! 1200 lb WEIGHT LIMIT BILL OF GOODS QTY: (1) 25' L-25 Mini Tower (1) HINGED BASE ASSEMBLY (1) 10 TOWER TRUSS (1) 7 TOWER TRUSS (1) 3 TOWER TRUSS (1) HEAD BLOCK (1) SLIDE BLOCK
More informationHSC EC 11-USA DETAN ROD SYSTEMS DT 14-US FAÇADE
HSC EC DETAN 11-USA ROD SYSTEMS DT 14-US FAÇADE HALFEN DETAN Rod Systems. The most Trusted Name. The most Elegant Application. With DETAN, architectural visions become a structural reality. DETAN Rod Systems
More informationSeries 2, 3, 4, & 5 Aluminum - Accessories
Wedge Lock Splice Plates Standard 4-hole pattern. Furnished in pairs, with hardware. One pair including hardware provided with each section. Boxed in pairs with hardware. For field installation drill 13
More informationHeavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return
CONTROLS Division of A-T Controls Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to,600,000 in. lbs. Double Acting and Spring Return THD S E R I E S The Triac line
More informationSection 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings
Section 2 Cast & Wrought Grooved Fittings Shurjoint Grooved Fittings... 56 Flow Data / Friction Resistance... 56 Ductile Iron Grooved Fittings 7110 / 7111 / 7112 / 7113 Elbows... 57 7120 / 7135 / 7130
More informationSSS Square Straight Steel
SSS Square Straight Steel Square Straight Steel Shaft One-piece construction Side, Tenon, or Pad mounting available Ground lug standard Galvanized anchor bolts and template included (4-bolt design) Base
More informationCommercial Grain Management Systems
Agri/Industrial Division Commercial Grain Management Systems Now with more roof options including peak load capacity of up to 50,000 lbs (22,680 kg)! MORE ROOF OPTIONS TO MEET YOUR SPECIFIC NEEDS! Chief
More informationKRANE-KING Jib & Gantry Cranes Gantries Free Standing Jibs Tension & Cantilevered Jibs Hoists
KRANE-KING Jib & Gantry Cranes Gantries Pages H.4 - H.17 Free Standing Jibs Pages H.18 - H.30 Tension & Cantilevered Jibs Pages H.31 - H.35 Hoists Pages H.36 - H.42 Index to Krane-King Jib & Gantry Cranes
More informationSTANDARD PRACTICE INSTRUCTION
STANDARD PRACTICE INSTRUCTION DATE: March 1, 2010 SUBJECT: Ladder Safety Program. REGULATORY STANDARD: 29 CFR 1910.25 Portable Wood Ladders. 29 CFR 1910.26 Portable Metal Ladders. 29 CFR 1926.1052-1060
More information8400 Series Fiber Distribution System
8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable
More informationFord Passenger Cars Mustang II Independent Front Suspension Installation Instructions
1935-1948 Ford Passenger Cars Mustang II Independent Front Suspension Installation Instructions 1-866-925-1101 www.totalcostinvolved.com The installation of the Total Cost Involved's Mustang Independent
More information3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits
3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.
More informationTYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System
1.01 Typical Installation Scope TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System Section 1- General Furnish labor, equipment, tools and material to install the PPB-300 Steel Piers as
More informationSupport Equipment. In This Section Mobile Ingredient Bins H Kettle Drainer H Rack/Tray Carts H
H SUPPORT EQUIPMENT Support Equipment In This Section Mobile Ingredient Bins H-1...198 Kettle Drainer H-2...199 Rack/Tray Carts H-3...200 Tray, Cup or Glass Rack Carts H-3-B...201 Cup & Glass Rack Carts
More informationCHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70
Proof Coil Chain Grade 28 Proof coil chain is suitable for use as towing chain, logging,fencing, trailer safety chain, boat anchors, security barriers or other general purposes where chain of high tensile
More information,000 psi Minimum Yield Strength. 70,000 psi Minimum Tensile Strength
Commercial Bins/Silos Total Value. Total Systems. Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, GSI offers the strongest and heaviest gauge
More information56-SDMS-07 REV. 01 SPECIFICATIONS FOR
56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice
More information6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT
4096-349 March 27, 2012 REVISION J ASSEMBLY MANUAL 6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT General Dynamics 1500 PRODELIN DRIVE NEWTON, NC 28658 INSTALLATION INSTRUCTIONS J Revised tool list,
More informationDisassembly and pressure discharge of STABILUS products prior to disposal
DE: X : X ES: X IT: X PR: X FR: X RO: X STABILUS products prior to disposal Revision no. Name / Date 534971 Kannewurf 05.02.2004 Revision no. Name / Date 537762 Kannewurf 05.07.2004 Revision no. Name /
More informationEXPANSION JOINT SELECTION GUIDE
EXPANSION JOINT SELECTION GUIDE The proper selection and application of an expansion joint is the determining factor in its operation and life. Improper selection and application will lead to problems
More information3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit
3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions
More informationShelving with Sloped Shelves
Shelving with Sloped Shelves Rousseau shelving with sloped shelves provides superior-quality gravity flow storage that integrates perfectly with other products in our Spider family. This unique product
More informationStopGate TM Barrier Arm GENERAL SPECIFICATIONS
StopGate TM Barrier Arm GENERAL SPECIFICATIONS I. GENERAL All StopGate Barrier Arms shall be designed and manufactured by Energy Absorption Systems, Inc., of Chicago, Illinois. II. DESCRIPTION OF SYSTEM
More informationWP Petroleum (Shanghai) Ltd. Tubular Handling Tools
WP Petroleum (Shanghai) Ltd. Tubular Handling Tools Quality Assurance WP Petroleum (Shanghai) Ltd [WP] is firmly committed to providing high quality Tubular Handing Tools and services, which meet or exceed
More informationFULL COLOR TAB #16 TECHNICAL DATA
FULL COLOR TAB #16 TECHNICAL DATA 276 General How Force Charts Weight Charts Seal Kits Conversion Charts TECHNICAL DATA How to determine the right cylinder size for the job. To determine what cylinder
More informationINSTALLATION INSTRUCTIONS AM rev. A
INSTALLATION INSTRUCTIONS AM16629-1 rev. A READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. INTRODUCTION NOTE: Zebra technologies Corporation
More informationRigid Entry Boots REB & RDEB. Installation Instructions
Rigid Entry Boots REB & RDEB Installation Instructions Body Flat Gasket Clamp Plate Band Clamps Compression Nut Duct Boot (Included with RDEB) Warning Caution Follow all federal, state and local laws governing
More informationGeneral Cable Support Information
General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices
More informationIBH. In-Between Handling Lift Trucks
IBH In-Between Handling Lift Trucks TECHNICAL DATA ELECTRICAL SYSTEM Model 1018: 12V, 105 A.H. rubber-clad industrial battery and built-in 8 amp. charger. Models 1518, 2018: 12V, 125 A.H. rubber-clad industrial
More information