1 2009 ROHN PRODUCTS LLC

2 G U Y E D T O W E R S S T A N D A R D 2 5 G G U Y E D T O W E R GENERAL USE The is available in the standard 0 section length and a 7 length which is UPS shippable. The uses double bolted joints, proven to be the best method of joining tower sections for sturdiness and dependability. As a guyed structure, the can rise to a maximum of 90. FEATURES Completely hot-dip galvanized after fabrication Accessories for are the same as the 20G and are completely interchangeable Built on 2 /2 equilateral triangle design High strength tubular legs joined by Zig-Zag cross members Each 0 section contains all required nuts and bolts inside one leg Extra heavy-duty /4 steel tubing side rails Continuous solid steel rod bracing QUICK REFERENCE PARTS & ACCESSORIES PAGE 4 INFORMATION PAGE 7 FOUNDATION INFORMATION PAGE 8 Phone (309) Fax (309) The Industry Standard

3 G U Y E D T O W E R S S T A N D A R D 2 5 G G U Y E D T O W E R S E C T I O N S G U Y E D T O W E R S 93/4 6/2 /4 8/4 2 O.D..87 I.D..25 O.D. (6 GA. wall) 5/6 O.D. Bracing.25 O.D. (6 GA. wall) /6 O.D. Bracing STANDARD TOP SECTION 25AG 2 /2 STANDARD SECTION - 0 Section 7-7 Section The 7 Section is UPS shippable. Additional top sections are shown on page 4. Phone (309) Fax (309) The Industry Standard 2

4 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F EPA (SQ. FT.) For Exposure B, Revision G EHS 5.8 P/N 90R EPA (SQ. FT.) For Exposure C, Revision G EPA (SQ. FT.), Revision F P/N 90R050 Tower Model Tower Height Windspeed (Rev. G) ROHN Tower EPA= Effective Projected Area Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance. DESIGN NOTES:. Tower designs are in accordance with ANSI/TIA-222-F-996 and ANSI/TIA-222-G-2005, Class I Structures. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two /2 diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ). 6. Antenna and mounts are assumed symmetrically placed at the tower top. PARTS LIST NOTES:. Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations. 2. Standard guys provided with each standard tower include an additional 6% length. 3. Anchor grounding (AGKGGX) and base grounding (BGK3GGX) with the tower material. 4. Installation information and a safety package (P/N: ACWS) are included with each tower. FOR FOUNDATION INFORMATION, PLEASE SEE PAGE 8. 3 Phone (309) Fax (309) The Industry Standard

5 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 22.6 OR /6 EHS 32 P/N: 90R /6EHS BG242 5/6THH 5/8TBE&J TBSAFETY GAR30 AGKGGX BGK3GGX CPC.5/ CB 3/4 x 2PP 40 ROHN Part No: 90R TOWER 2.4 OR /6 EHS 40 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 50 ROHN Part No: 90R TOWER 20.3 OR /6 EHS 48 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 60 ROHN Part No: 90R TOWER 9.4 OR /6 EHS 56 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 70 ROHN Part No: 90R TOWER 8.6 OR /6 EHS 64 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 80 ROHN Part No: 90R080 Phone (309) Fax (309) The Industry Standard 4

6 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 8.0 OR /6 EHS 8 3 CB 3/6EHS BG242 5/6THH 5/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R090 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 7.5 OR /6 EHS 80 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 00 ROHN Part No: 2590R TOWER 7.0 OR /6 EHS 0 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R0 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 6.6 OR /6 EHS 96 P/N: 90R20 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 20 ROHN Part No: 90R TOWER 6.2 OR /6 EHS 04 P/N: 90R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 30 ROHN Part No: 90R30 5 Phone (309) Fax (309) The Industry Standard

7 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 5.9 OR /6 EHS 2 P/N: 90R /6EHS BG242 5/6THH 5/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 90R TOWER 5.5 OR /6 EHS 4 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R50 GAC305 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 5.3 OR /6 EHS 5 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R60 GAC305 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 5.0 OR /6 EHS 6 5 3/6EHS BG242 5/6THH 3/8TBE&E CB TBSAFETY ROHN Part No: 90R P/N: 90R70 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP TOWER 4.8 OR /6 EHS 7 5 3/6EHS BG242 5/6THH 3/8TBE&E CB TBSAFETY ROHN Part No: 90R P/N: 90R80 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 6

8 G U Y E D T O W E R S 9 0 M P H R E V. G, 7 0 M P H R E V. F TOWER 4.5 OR /6 EHS 8 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 90R P/N: 90R90 GAC305 AGKGGX BGK3GGX 3 2 CPC.5/ /4x2PP 7 Phone (309) Fax (309) The Industry Standard

9 G U Y E D T O W E R S 0 M P H R E V. G, 9 0 M P H R E V. F TOWER 3.4 OR /6 EHS 3 CB 3/6EHS BG242 5/6THH 5/8TBE&J TBSAFETY ROHN Part No: 0R P/N: 0R040 GAR30 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 2.6 OR /6 EHS 40 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 50 ROHN Part No: 0R TOWER.9 OR /6 EHS 48 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 60 ROHN Part No: 0R TOWER.3 OR /6 EHS 6 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R070 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 0.9 OR /6 EHS 7 3 CB 3/6 EHS BG242 5/6 THH 3/8 TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R080 AGKGGX BGK3GGX CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 8

10 G U Y E D T O W E R S TOWER 0.5 OR /6 EHS 72 P/N: 0R090 0 M P H R E V. G, 9 0 M P H R E V. F 8 3 3/6EHS BG242 5/6THH 5/8TBE&E TBSAFETY AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 90 ROHN Part No: 0R TOWER 0.2 OR /6 EHS 9 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R00 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.9 OR /6 EHS 0 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R0 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.7 OR /6 EHS 96 P/N: 0R20 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 20 ROHN Part No: 0R TOWER 9.3 OR /6 EHS 04 P/N: 0R /6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 30 ROHN Part No: 0R30 9 Phone (309) Fax (309) The Industry Standard

11 G U Y E D T O W E R S TOWER 9.2 OR /6 EHS 2 P/N: 0R40 0 M P H R E V. G, 9 0 M P H R E V. F 3 4 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC305 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 0R TOWER 9.0 OR /6 EHS 4 5 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 0R P/N: 0R50 GAC3455TOP AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.8 OR /6 EHS 5 5 CB 3/6EHS BG242 5/6THH /2TBE&J TBSAFETY ROHN Part No: 0R P/N: 0R60 GAC3455TOP AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.7 OR /6 EHS P/N: 0R BASE CB2 3/6EHS BG242 5/6THH 3/8TBE&E /2TBE&J TBSAFETY GAC305 GAC3455TOP AGKGGX BGK3GGX CPC.5/ INNER ANCHOR OUTER ANCHOR 3/4x2PP 70 ROHN All par ts shown in table are included when ordering Part No: 0R TOWER 8.6 OR /6 EHS P/N: 0R BASE CB2 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY GAC3455TOP AGKGGX BGK3GGX CPC.5/ INNER ANCHOR OUTER ANCHOR 3/4x2PP 80 ROHN All par ts shown in table are included when ordering Part No: 0R80 Phone (309) Fax (309) The Industry Standard 0

12 G U Y E D T O W E R S G U Y E D T O W E R S TOWER 8.5 OR /6 EHS P/N: 0R90 0 M P H R E V. G, 9 0 M P H R E V. F 8 6 3/6EHS BG242 5/6THH 3/8TBE&E GAC3455TOP AGKGGX BGK3GGX BASE CB2 /2TBE&J 2 CPC.5/.75 6 INNER ANCHOR OUTER ANCHOR TBSAFETY 6 3/4x2PP 90 ROHN All par ts shown in table are included when ordering Part No: 0R90 Phone (309) Fax (309) The Industry Standard

13 G U Y E D T O W E R S TOWER 0.8 OR /6 EHS 32 P/N: 30R M P H R E V. G, 0 M P H R E V. F 3 3/6EHS BG242 5/6THH 5/8TBE&J TBSAFETY GAR30 AGKGGX BGK3GGX CPC.5/ CB 3/4x2PP 40 ROHN Part No: 30R TOWER 0. OR /6 EHS 4 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R050 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.7 OR /6 EHS 5 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R060 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 9.2 OR /6 EHS 6 2 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R070 AGKGGX BGK3GGX CPC.5/ /4x2PP TOWER 8.9 OR /6 EHS 7 3 CB 3/6EHS BG242 5/6THH 3/8TBE&E TBSAFETY ROHN Part No: 30R P/N: 30R080 AGKGGX BGK3GGX CPC.5/ /4x2PP Phone (309) Fax (309) The Industry Standard 2

14 G U Y E D T O W E R S TOWER 8.6 OR /6 EHS 72 P/N: 30R M P H R E V. G, 0 M P H R E V. F 8 3 3/6EHS BG242 5/6THH 3/8TBE&E AGKGGX BGK3GGX CPC.5/ CB TBSAFETY 3/4x2PP 90 ROHN Part No: 30R TOWER 8.4 OR /6 EHS 80 P/N: 30R /6EHS BG242 5/6THH 3/8TBE&E AGKGGX BGK3GGX CPC.5/ CB TBSAFETY 3/4x2PP 00 ROHN Part No: 30R00 3 Phone (309) Fax (309) The Industry Standard

15 G U Y E D T O W E R S P A R T S & A C C E S S O R I E S O.D..38 I.D..25 N.P.T O.D I.D / O.D I.D. - /4 8-3/6-4 /4 TOP SECTION 25AG TOP SECTION 25AG2 TOP SECTION 25AG3 TOP SECTION 25AG4 8-3/2-5/ O.D I.D. 3 4 SHORT BASE SB TOP SECTION 25AG5 BEARING PLATE BPL LONG LEGS PROVIDE EXTRA EARANCE FOR INSTALLATION OF EQUIPMENT. BOLTS TO TOP OF STANDARD SECTION. DRILLED TO ACCEPT TB3 OR TB4 THRUST BEARING. ASSEMBLY PLATE / TOP BEACON PLATE APL FOR MOUNTING BEACON. BOLTS TO TOP OF STANDARD SECTION. 5 SHORT BASE SB5 3 4 HINGED SHORT BASE SBH HINGED TO BOTTOM. THESE BASE SECTIONS FOR EMBEDMENT IN CONCRETE. CONCRETE BASE PLATE BPC* FOR USE WITH PIER PIN EMBEDDED IN CONCRETE. PIER PIN 3/4x2PP MUST BE ORDERED SEPARATELY. HINGED BASE PLATE BPH* BOLTS TO CONCRETE. HINGED TO ALLOW TOWER TO BE ROTATED UP FROM BASE DURING INSTALLATION. BASE BOLTS /2x2BB MUST BE ORDERED SEPARATELY. SINGLE DRIVE-IN BASE SDB TO BE DRIVEN DIRECTLY INTO GROUND. TAPERED BASE 25TGA* CAN BE USED WITH RACAL DECCA A497L BASE INSULATOR OR WITH 3/4x2PP. * TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING. Phone (309) Fax (309) The Industry Standard 4

16 G U Y E D T O W E R S P A R T S & A C C E S S O R I E S PEAK ROOF MOUNT PR* ADJUSTABLE HINGED FEET CONFORM TO NEARLY ANY ROOF PITCH. BOLTS TO ROOF SURFACE. FLAT ROOF MOUNT FR* BOLTS DIRECTLY TO FLAT ROOF SURFACE. SIDE ARM MOUNT UHF FOR UHF & FM ANTENNAS. SIDE ARM BRACKET SA253UA MOUNTING TUBE PROVIDED IS 3 LONG, 2 - /4 O.D. TOP MOUNT 25TDMKD - NO PIPE 25TDM2S3KD - 2 X 7 PIPE 25TDM25S3KD - 2 /2 X 7 PIPE 25TDM3S3KD - 3 X 7 PIPE 25TDM35S3KD - 3 /2 X 7 PIPE TOP PLATE INUDES BUILT IN GUY LUGS. BOLTS TO SWAGED TOP OF STANDARD SECTION. LOWER PLATE CONNECTS WITH U-BOLTS. SET SCREWS SECURE MOUNTING PIPE. FACE MOUNT DM2 MOUNTING PIPE IS 5 LONG, 2 STD. ADJUSTABLE HOUSE BRACKET HB25AG 0-5 HB25BG 0-24 HB25CG 0-36 HEAVY DUTY UNIVERSAL HOUSE BRACKET HBUTVRO ADJUSTABLE TO POSITION TOWER 8-36 FROM WALL. UNIVERSAL EAVE BRACKET EB25 HINGED ALLOWS TOWER LEG AMPS TO REMAIN PERPENDICULAR TO GROUND WHILE BOLT DOWN SUPPORTS ROTATE TO LAY FLAT ALONG PITCHED ROOF OR EAVE. GUY BRACKET GAD MOUNTS TO ANY TOWER AT ANY HORIZONTAL BRACE. TORQUE BARS TB25D OPTIONAL, FOR USE WITH GAD (NOT SHOWN). ANTI-IMB PANELS 25A3 THREE ANTI-IMB PANELS TO BOLT TO EXISTING STANDARD TOWER SECTION. TORQUE ARM STABILIZER ASSEMBLY TA25 ANTI-TWIST DEVICE LOCATED IN THE AREA OF ANTENNAS. PROVIDES SIX-WAY GUYING. BOLTS TO TOWER AT ANY SECTION JOINT. ATTACHED WITH JOINT BOLTS. MUST BE INSTALLED AS SECTIONS ARE JOINED TOGETHER. * TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING. 5 Phone (309) Fax (309) The Industry Standard

17 GUYED TOWERS PA R T S & A CC E S S O R I E S 90º JOINTS 2590MM - BOTH ENDS SWAGED JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. 90º JOINTS 2590FF - BOTH ENDS OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. 90º JOINTS 2590FM - ONE END SWAGED, ONE OPEN JOINTS ARE NOT DRILLED WHERE THEY SLIP FIT TO SECTIONS. CAN BE FIELD DRILLED OR CUSTOM CONNECTED TO MEET PARTICULAR NEEDS. ACCESSORY SHELF AS FOR MOUNTING MANY POPULAR ROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS. RP BEARING/ACCESSORY SHELF BAS RP CM DRILLING TO ACCEPT THRUST BEARING ON TOP PLATE. ACCESSORY SHELF DRILLED FOR MOUNTING MANY POPULAR ROTORS. ROTOR POST SAFETY RING SR245 SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED. THRUST BEARING TB3 - SUPPORTS UP TO 2 O.D. MAST. TB4 - SUPPORTS UP TO 3 O.D. MAST. MOUNTS TO BAS OR BLP. WORK PLATFORM WP SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED. TOWER BUSHING TB50 - -/4 I.D. X 2 O.D. TB75 - -/2 I.D. X 2 O.D. FOR USE ON 25AG TOP SECTION REFER TO PAGE 2. ERECTION FIXTURE EF /2 SHEAVE WITH 3/8 I.D. GROOVE. NOTE: ERECTION FIXTURES ARE FOR LIFTING ONE 0 SECTION AT A TIME AND ARE NOT INTENDED FOR THE LIFTING OF PERSONNEL. Phone (309) Fax (309) The Industry Standard 6

18 GUYED TOWERS G R O U N D I N G I N F O R M AT I O N 2 IN. 84 IN..63 IN..63 IN IN. IN. 2 IN. 84 IN. GAR30 ( 7,330 LBS. ALLOWABLE LOAD)* 5.25 IN. ( 7,330 LBS. ALLOWABLE LOAD)* 8 IN. 84 IN..63 IN. 2 IN IN..38 IN. GAC305 ( 7,330 LBS. ALLOWABLE LOAD)* 2 IN. 2.5 IN. P/N STAMPED HERE.75 IN. 2 IN. GAC3455TOP ( 7,670 LBS. ALLOWABLE LOAD)* ANCHOR RODS Notes:. and GAC305 rods are supplied with type EP25343 and EP25345 equalizer plates - as in type GAR30 rod. 2. Part number suffixes 3,5 and 55 denotes 3 or 5 holes in equalizer plates. 3. Type EE equalizer plates are supplied in pairs for eye and eye turnbuckles. 4. Type EJ equalizer plates are used with eye and jaw turnbuckles. * INUDES INCREASE IN ALLOWABLE STRESSES. BASE ANCHOR * Clamp is not included in grounding kit. It must be ordered as a separate item. TINNED BARE COPPER WIRE (NO. 4 MAX) 6.00 IN. MIN. (52mm) ATTACH TO LEG WITH SUPPLIED LEG AMP AMP NO. : GUY WIRE SIZE* P/N CPC.5/.75: 3/6 IN. - /2 IN. TINNED BARE COPPER WIRE (NO. 4 MAX) GROUND ROD AMP 0 FT. (2.483M) COPPER AD GROUND ROD GROUND ROD AMP 6.00 IN.MIN. (52mm) 0 FT. (2.483M) COPPER AD GROUND ROD 7 Phone (309) Fax (309) The Industry Standard

19 GUYED TOWERS STANDARD FOUNDATIONS Pier Pin Pier Pin 4 IN. Projection 4 IN. Projection 6 IN. 3 IN. Maximum No. 3 Circular ties, 3 in. on centers with 6 in. laps (8) No. 7 vertical bars equally spaced on a 2in. diameter circular cage 4 FT. 6 IN. No. 3 Circular ties, 3 in. on centers with 6 in. laps (0) No. 7 vertical bars equally spaced on a 27in. diameter circular cage 4 FT. 6 IN. ELEVATION VIEW ELEVATION VIEW 2 FT. 6 IN. 3 FT. 3 FT. 2 FT. 6 IN. 6 IN. 3 IN. Maximum Alternate Square Pier Alternate Square Pier PLAN VIEW PLAN VIEW CB2 CB Concrete Volume =.2 CU. YDS. Concrete Volume = 0.8 CU. YDS. STANDARD ANCHOR BLOCKS Centerline of anchor Ground line Ground line 40º 3 FT. Centerline of anchor Ground line Ground line 42º #5 Horizontal bars equally spaced at 0 IN. O-C all around #6 Horizontal bars equally spaced at 0.5 IN. O-C all around 4 FT. #3 Stirrups equally spaced 2 IN. O-C #3 Stirrups equally spaced 2 IN. O-C FT. FT. 6 IN. 3 FT. 4 FT. 4 FT. 6 FT. ELEVATION VIEW PROFILE VIEW ELEVATION VIEW PROFILE VIEW Concrete Volume 0.4 CU. YDS. per block.3 CU. YDS. total for 3 Concrete Volume.3 CU. YDS. per block 4.0 CU. YDS. total for 3 NOTE: 3 Minimum cover required on all reinforcing bars. Phone (309) Fax (309) The Industry Standard 8

20 2009 ROHN PRODUCTS LLC

STANDARD 25G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard

STANDARD 25G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard G GUYED TOWERS 25G STANDARD 25G GUYED TOWER ROHN 25G The first. The original. includes REV. F & REV. G 25G GENERAL USE The 25G is available in the standard 0 section length and a 7 length which is UPS

More information

STANDARD 80 SERIES GUYED TOWER GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard

STANDARD 80 SERIES GUYED TOWER GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard G GUYED TOWERS - 80 STANDARD 80 SERIES GUYED TOWER 80 SERIES GENERAL USE The ROHN Model 80 Guyed Tower is designed with variable sized legs and braces to allow construction to heights of 1000. This tower

More information

EFFECTIVE WIND VELOCITY FORMULA SHEET

EFFECTIVE WIND VELOCITY FORMULA SHEET RM ROOF MOUNTS EFFECTIVE WIND VELOCITY FORMULA SHEET ROHN recommends a minimum mph Effective Wind be used for determining ballast requirements. Refer to page 2 for ballast requirements and general notes.

More information

EFFECTIVE WIND VELOCITY FORMULA SHEET

EFFECTIVE WIND VELOCITY FORMULA SHEET ROOF MOUNTS EFFECTIVE WIND VELOCITY FOULA SHEET ROHN recommends a minimum mph Effective Wind be used for determining ballast requirements. V = C1 C2 V e V e = Effective Wind at centerline of antenna for

More information

Round: 95/53/37 Flat: 57/31/22 Round: 77/55/28 Flat: 46/33/17

Round: 95/53/37 Flat: 57/31/22 Round: 77/55/28 Flat: 46/33/17 Tower Kits Tower Height: 40' 50' 60' 70' Part Number 4.618.G000.040 4.618.G000.050 4.618.G000.060 4.618.G000.070 List Price $4026.00 $4425.00 $4825.00 $5224.00 Round: 100/54/38 Flat: 60/32/22 Round: 80/60/30

More information

PRODUCT NAME ORDER # PAGE # ANTENNAS

PRODUCT NAME ORDER # PAGE # ANTENNAS PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband

More information

INTRODUCTION. Sincerely, Dan Ianello, PE President. Toll Free: NELLO Fax:

INTRODUCTION. Sincerely, Dan Ianello, PE President. Toll Free: NELLO Fax: INTRODUCTION Nello Corporation specializes in the Communications Support Infrastructure market. We have a strategy of providing innovative and cost effective products to an industry that relies on quality,

More information

Table of Contents. Kit Maximum Examples Index by Kit Number Terms and Conditions...Inside Back Cover

Table of Contents. Kit Maximum Examples Index by Kit Number Terms and Conditions...Inside Back Cover Table of Contents Antenna Mounts Light Standoff Mounts...2 Medium Standoff Mounts...4 Heavy Standoff Mounts...6 Fixed Crossover Assemblies...8 Universal Crossover Assemblies...8 Hybrid Crossover Assemblies...9

More information

KROFTMAN CONTAINER SHELTER TC812

KROFTMAN CONTAINER SHELTER TC812 KROFTMAN CONTAINER SHELTER CONTENT FRAME P82-FR 82-0 82-02 82-03 82-0 82-05 82-06 82-07 parts list frame part numbers main frame base plan, frame plan available hight inside detail 0 detail 02, 03 Roof

More information

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with

More information

Installation Instructions

Installation Instructions Description Instructions given in this bulletin apply to either a standard, unshielded or high-performance, shielded antenna. The antenna consists of a two-piece reflector, braced by a back structure;

More information

WIDE-CORRUGATION FARM GRAIN BINS

WIDE-CORRUGATION FARM GRAIN BINS SM WIDE-CORRUGATION FARM GRAIN BINS B R O C K G R A I N B I N S B rock Grain Systems has a world-wide reputation for providing reliable on-farm storage that allows farmers to market their grain when they

More information

LSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders

LSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders C. Stairs & Ladders 1. General Requirements a. A stairway or ladder must be provided at all worker points of access where there is a break in elevation of 19 inches (48 cm) or more and no ramp, runway,

More information

LMS 106 CR MODEL MOBILE TOWER

LMS 106 CR MODEL MOBILE TOWER LMS 106 CR MODEL MOBILE TOWER 106 TALL, 6 EA SECTIONS LEGS ASTM A500-07, A53-12, GRADE B, US CARBON STEEL Lifetime Warranty TILT BASE ASSEMBLY INTEGRATED INTO TRAILER. Lifetime Warranty 3 SECTOR ANTENNA

More information

Pecco SK 225 TOWER CRANE. 106 ft (32.3m) 19,900 lbs kg. Hook Heights. Sections I

Pecco SK 225 TOWER CRANE. 106 ft (32.3m) 19,900 lbs kg. Hook Heights. Sections I 11 x S35 = 212'-11" (64.9m) 11 x S35 = 212'-11" (64.9m) Pecco SK 225 TOER CRANE 200 ft (61.0m) 7,100 lbs 3 200 kg 181 ft (55.2m) 8,800 lbs 4 000 kg 163 ft (49.7m) 10,600 lbs 4 800 kg 144 ft (43.9m) 12,800

More information

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the

More information

Hi-Tech specially designed components allow for fast and easy assembly.

Hi-Tech specially designed components allow for fast and easy assembly. OPEN SHELVING MEDIUM, HEAVY AND EXTRA HEAVY-DUTY HI-TECH STEEL SHELVING Open Starter Units Include: Two beaded front posts, two angle back posts, one pair of back sway braces, two pair of side sway braces

More information

Technical Math 2 Lab 3: Garage Door Spring 2018

Technical Math 2 Lab 3: Garage Door Spring 2018 Name: Name: Name: Name: As you may have determined the problem is a broken spring (clearly shown on the left in the picture below) which needs to be replaced. I. Garage Door Basics: Common residential

More information

LMS 120 XHD MODEL MOBILE TOWER

LMS 120 XHD MODEL MOBILE TOWER LMS 120 XHD MODEL MOBILE TOWER MOBILE TOWER 120 TALL, 6 EA SECTION LEGS ASTM A500-07, A53-12, GRADE B, US CARBON STEEL Lifetime Warranty TILT BASE ASSEMBLY INTEGRATED INTO TRAILER. Lifetime Warranty 3

More information

Safety Ladders: Hot Dip Galvanized/Stainless Steel

Safety Ladders: Hot Dip Galvanized/Stainless Steel Y-Spar Guide-rail profile: 50 x 32 mm. Comes with joint plate. Mounting brackets extra to order. Recommended mounting distance 1400 mm - max. 1680 mm. Installation of bracket to ladder is carried out through

More information

Rush and setup xstage S4

Rush and setup xstage S4 Rush and setup xstage S4 S4 is an ideal option for use during the biggest events, thanks to its unique adjustability from 1 m (39.37") up to 2.5 m (98.4") (floor height). Very large adjustability range,

More information

Detroit Speed, Inc. Mini Tubs Camaro/Firebird P/N:

Detroit Speed, Inc. Mini Tubs Camaro/Firebird P/N: Detroit Speed, Inc. Mini Tubs 1967-1969 Camaro/Firebird P/N: 040401 The Detroit Speed Mini-Tubs are inner wheel housings designed to accommodate a wider wheel and tire package. They are engineered for

More information

ANTENNA SUPPORT STRUCTURES

ANTENNA SUPPORT STRUCTURES 14.1 Rooftop Ballast Frame for Wireless Antennas General Description Non-penetrating Rooftop Ballast Frames enable installation of wireless panel antennas for a sector. The Frames are secured using concrete-block

More information

TITAN Motor Truck Scale

TITAN Motor Truck Scale S C A L E S Instruction Manual TITAN Motor Truck Scale Model: 00 Series FAIRBANKS 00 by Fairbanks Scales Inc. All rights reserved 0 Revision # 0/0 Amendment Record Titan 00 Series Motor Truck Scale 0 Manufactured

More information

LADDER SAFETY PROGRAM

LADDER SAFETY PROGRAM All ladders at Craven Community College must be constructed and used in accordance with OSHA regulations and ANSI standards. All commercially manufactured ladders must have a label indicating it meets

More information

ANTENNA PARTS CATALOG

ANTENNA PARTS CATALOG ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net Call to order: (815) 244-3500 SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine Screw

More information

Product Information. December 1, The Cable Connection 52 Heppner Drive Carson City, NV 89706

Product Information. December 1, The Cable Connection 52 Heppner Drive Carson City, NV 89706 Product Information December 1, 2016 The Cable Connection 52 Heppner Drive Carson City, NV 89706 800.851.2961 775.885.1443 Fax: 775.885.2734 E-mail: info@ultra-tec.com www.ultra-tec.com Summary of Cable

More information

Detroit Speed, Inc. Mini Tubs Camaro/Firebird P/N:

Detroit Speed, Inc. Mini Tubs Camaro/Firebird P/N: Detroit Speed, Inc. Mini Tubs 1967-1969 Camaro/Firebird P/N: 040401 The Detroit Speed Mini-Tubs are inner wheel housings designed to accommodate a wider wheel and tire package. They are engineered for

More information

Commercial Bins/Silos

Commercial Bins/Silos Commercial Bins/Silos Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, Grain Systems offers the strongest and heaviest gauge storage tanks

More information

INSTRUCTION MANUAL L WIND CONE

INSTRUCTION MANUAL L WIND CONE Cooper Industries DOCUMENT September 29, 2009 Revision B Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 Title: INSTRUCTION

More information

INFORMATIVE MATERIAL 5 QUICK LASHING GUIDE. Cargo securing on CTUs for transports on Road, Combined Rail and in Sea Area A, B & C SEA AREAS

INFORMATIVE MATERIAL 5 QUICK LASHING GUIDE. Cargo securing on CTUs for transports on Road, Combined Rail and in Sea Area A, B & C SEA AREAS Page 65 INFORMATIVE MATERIAL 5 QUICK LASHING GUIDE Cargo securing on CTUs for transports on Road, Combined Rail and in Sea Area A, B & C SEA AREAS A B C H s 8 m 8 m < H s 12 m H s > 12 m Baltic Sea (incl.

More information

Style 233-L & 234-L Rubber Joints

Style 233-L & 234-L Rubber Joints Style 33-L & 3-L Rubber Joints Style 33-L Rubber s are designed for piping systems that experience large lateral offsets due to settlement. The Style 33-L is a low profile triple arch design with a built-in

More information

Maintenance Information

Maintenance Information 16606022 Edition 3 May 2014 Air Drill 728 Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these potentially

More information

A. This Section includes the following types of sectional overhead doors:

A. This Section includes the following types of sectional overhead doors: SECTION 08361 - SECTIONAL OVERHEAD DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Commercial Hopper Tanks (CHT)

Commercial Hopper Tanks (CHT) Commercial Hopper Tanks (CHT) Total Value. Total Systems. NCHT & FCHT Series The right tank for the right job. Commercial hopper tanks are typically used in applications where routine clean out is required,

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

When buying Crosby you re buying more than product, you re buying Quality.

When buying Crosby you re buying more than product, you re buying Quality. From a 2 ton capacity snatch to a 6000 metric ton capacity crane, McKissick can make a McKissick s major involvement in the block McKissick When buying Crosby you re buying more than product, you re buying

More information

CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002

CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002 CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002 Case Study compiled by: Rhonda Gatzke, Member GEO 11/2002 Some Some of of the the project project participants: participants: Metro Metro

More information

Pecco SK TOWER CRANE. FREESTANDING (stationary) Hook Heights. 200 ft (60.9m) 8,300 lbs kg. 180 ft (55.0m) 10,300 lbs kg

Pecco SK TOWER CRANE. FREESTANDING (stationary) Hook Heights. 200 ft (60.9m) 8,300 lbs kg. 180 ft (55.0m) 10,300 lbs kg x S5 = '-" (6.9m) x S5 = '-" (6.9m) Pecco SK 80-0 TOER CRANE 80 ft (55.0m) 00 ft (60.9m) 0,00 lbs 700 kg 8,00 lbs 750 kg ft (.m) 6 ft (9.m),00 lbs 5 500 kg,700 lbs 6 700 kg ft (7.6m) 7,500 lbs 7 900 kg

More information

GRC. R & C Agency Trapeze Lighting

GRC. R & C Agency Trapeze Lighting GRC R & C Agency 2013 Lighting 3 TW-001 Straight Fixture Basic, economical straight fixture. Lamp can only be adjusted downward. Max. / Dichroic TW-001A Twist Action Fixture Multi functional trapeze fixture

More information

FlexLink conveyor Series Y

FlexLink conveyor Series Y FlexLink conveyor Series Y 3 Introduction New conveyor with focus on hygiene The new FlexLink hygiene conveyor was designed to meet the following requirements of special interest to the dairy, food, and

More information

BESTEEL 170 SERIES CURTAIN TRACKS

BESTEEL 170 SERIES CURTAIN TRACKS BESTEEL 170 SERIES CURTAIN TRACKS BL = Black Finish 2XX Series Track Systems have a black finish. Parts Included 170 (270) 170 BESTEEL CWANA code CORD OPERATED/MOTORIZED 171 (271) 171-R (271-R) 260 172

More information

Innovative designs to improve your bottom line.

Innovative designs to improve your bottom line. Innovative designs to improve your bottom line. UNIQUELY DESIGNED WALLS FOR ADDITIONAL STRENGTH The flat sided (trapezoidal) configuration with built-in wind bands, offered as a standard design feature

More information

D and DL Annular Blowout Preventers

D and DL Annular Blowout Preventers D and DL Annular Blowout Preventers In the unique design of the Cameron DL Annular BOP, closing pressure forces the operating piston and pusher plate upward to displace the solid elastomer donut and force

More information

*We only delivery to Western portions of Oregon *Prices subject to change without notice

*We only delivery to Western portions of Oregon *Prices subject to change without notice Alan's Factory Outlet Carport Prices in Oregon *We only delivery to Western portions of Oregon *Prices subject to change without notice 1-800-488-6903 www.alansfactoryoutlet.com Regular Style Carport Prices

More information

panelclaw.com Polar Bear III for 10 Degree

panelclaw.com Polar Bear III for 10 Degree panelclaw.com Polar Bear III for 10 Degree Installation Manual Document Number 9910024 Rev A March 2014 Revision History Rev ECO # Date Description of Changes Approved By 01 TBD 02-FEB-14 Initial Draft

More information

Albuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN. Bid Tabulation Abstract

Albuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN. Bid Tabulation Abstract Albuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN Bid Tabulation Abstract ITEM # DESCRIPTION BRAND NAME Fabric - Smooth galvanized, 2 in. mesh, open hearth

More information

Specifications LS-248H II. 200-Ton ( metric ton) Hydraulic Lattice Boom Crawler Crane

Specifications LS-248H II. 200-Ton ( metric ton) Hydraulic Lattice Boom Crawler Crane Specifications Hydraulic Lattice Boom Crawler Crane LS-248H II 200-Ton (181.50 metric ton) Shown with side frame auxiliary counterweights. Not to Scale General dimensions feet meters Basic boom length

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS WIND GENERATOR KIT Complete Set Including All Accessories 500 Watts rated at 12,5 m/s (= 28 mph) 6 Meter (= 20 ft.) Free-Standing Tower ASSEMBLY INSTRUCTIONS Contents WIND GENERATOR KIT Complete Set Including

More information

OPERATION MANUAL 17 Crown Block Sheave Manufactured by Wireline Technologies, Inc. Serial Number

OPERATION MANUAL 17 Crown Block Sheave Manufactured by Wireline Technologies, Inc. Serial Number OPERATION MANUAL 17 Crown Block Sheave Manufactured by Wireline Technologies, Inc. Serial Number Introduction This manual explains the use and care of 17 Crown Block Sheaves manufactured by Wireline Technologies,

More information

10 X 10 NPMM Installation

10 X 10 NPMM Installation May 20, 2016 Revision E ASSEMBLY MANUAL Installation General Dynamics SATCOM Technologies 1700 Cable Drive NE Conover NC 28613 USA Phone 770-689-2040 www.gdsatcom.com 10' x 10' NPMM INSTALLATION INSTRUCTIONS

More information

THEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES

THEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES LMS 85 HW 85 MODEL, 5 EA-21 MULTIPLE SECTIONS Lifetime Warranty, 36 X 21 SUPER HEAVY-DUTY BASE SECTION, ALL SECTIONS ASTM A500-07, A53-12, GRADE B, CARBON STEEL, SCHEDULE 40 STRUCTURAL TUBING Lifetime

More information

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs CONTROLS Division of A-T Controls, Inc. THD Series Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 In-lbs Double Acting and Spring Return Symmetric and

More information

Zip Tie Domes - 3V 3/8 Assembly Manual

Zip Tie Domes - 3V 3/8 Assembly Manual Zip Tie Domes - 3V 3/8 Assembly Manual Instructions for Assembling the 25 Foot 3V 3/8 Frequency Geodesic Dome Tools Needed: 8 foot Step Ladder, Wire Cutters SAFETY RULES: Do Not Climb On the Dome. It is

More information

Spring Cable Reels EXEL

Spring Cable Reels EXEL Spring Cable Reels EXEL Conductix - Wampfler designs and manufactures high-performance electrification systems for mobile equipment used in heavy industries such as iron and steel, food processing, cement

More information

DIGIFLO ELECTRONIC FLOWMETER

DIGIFLO ELECTRONIC FLOWMETER DIGIFLO ELECTRONIC FLOWMETER PIPE FITTING INSTALLATION MANUAL SADDLE MACHINED IN-LINE BODY MOLDED IN-LINE BODY MOLDED TEE Blue-White R Industries, Ltd. F-2000 Page 2 1.0 Temperature vs. Pressure Temperature

More information

SuperTrac. Axle. Service & Maintenance. Manual

SuperTrac. Axle. Service & Maintenance. Manual SuperTrac Axle Service & Maintenance Manual Table of Contents Page Exploded Views Section 1: General Information General Warnings Description of Axle Models Identifications Section 2: Installation Axle

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts...

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts... S 1 Index PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3 GROUND and pole MOUNT SYSTEMS...5 Power Rail Module Mounting System...6 Power Rail Extrusions...7 Power Rail Commercial Extrusions...7

More information

Home Frontload Washers

Home Frontload Washers Home Frontload Washers Refer to Page 3 for Model Numbers Parts FLW1536C_802849 www.alliancelaundry.com Part No. 802849R9 January 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

RIG-I-FLEX 140 SERIES CURTAIN TRACKS

RIG-I-FLEX 140 SERIES CURTAIN TRACKS RIG-I-FLEX 140 SERIES CURTAIN TRACKS Parts Included 140 RIG-I-FLEX CWANA code CORD OPERATED/MOTORIZED WALK-ALONG 140 (240) 140-R (240-R) 141 (241) 141-R (241-R) 142 (242) 142-R (242-R) STRAIGHT CURVED

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

WE BELIEVE IN A

WE BELIEVE IN A WE BELIEVE IN A COMPANY CONTENTS TECNOPALI North Europe is the largest steel lighting pole, mast and accompanying steel structure producer in the Baltics, located in Daugmale, Latvia. Tecnopali North Europe

More information

Sunfire Series. Full Size Electric Convection Ovens. Parts List. Models SCO-ES-10S SCO-ES-20S. Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/15

Sunfire Series. Full Size Electric Convection Ovens. Parts List. Models SCO-ES-10S SCO-ES-20S. Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/15 Sunfire Series Full Size Electric Convection Ovens Parts List Models SCO-ES-0S SCO-ES-20S Document Number: S_EO_PL_CONVECTION_SCOES Updated: 2/5 Rating Plate Location Door Door Motor Motor Rating Plate,

More information

2.88 OD Universal Mast Mount

2.88 OD Universal Mast Mount Revision A January 19, 2006 ASSEMBLY MANUAL 2.88 OD Universal Mast Mount GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com 2.88 O.D. Universal

More information

Structural Support Products. Wireless Site Solutions Ordering Guide Version 2.1

Structural Support Products. Wireless Site Solutions Ordering Guide Version 2.1 Structural Support Products Wireless Site Solutions Ordering Guide Version 2.1 TOWER MOUNTS G2 Series High Capacity Sector Frames Quick-Vee Medium Capacity Sector Frames Sector Frame Reinforcement Kits

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories The following is a list of accessories and fittings that can be provided with S8 tray. For more information on these items, contact our Engineering Department. Fittings Horizontal Bends 30 Bends with 24,

More information

Appendix 4 Exploded Views & Parts Lists. 34 Generac Power Systems, Inc.

Appendix 4 Exploded Views & Parts Lists. 34 Generac Power Systems, Inc. Appendix Exploded Views & Parts Lists CENTURION Home Standby Generator Enclosure - Drawing No. E 7 8 7 7 8 7 8 8 7 Generac Power Systems, Inc. Appendix Exploded Views & Parts Lists CENTURION Home Standby

More information

SITE ACCESSORIES CATALOG USA.

SITE ACCESSORIES CATALOG USA. SITE ACCESSORIES CATALOG USA 2019 www.trylon.com Pictorial Table of Contents Page 2 Sector V-Frames Page 4 RRU Mounts Page 5 Rotatable Standoff Mounts Page 6 Light Standoff Mounts Page 8 Medium Standoff

More information

Non Penetrating Mast Mount for 2.4M Antennas

Non Penetrating Mast Mount for 2.4M Antennas April 27, 2007 INSTALLATION MANUAL Non Penetrating Mast Mount for 2.4M Antennas GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com Non-Penetrating

More information

Harding Steel Tri-Lift

Harding Steel Tri-Lift Harding Steel Tri-Lift World Class Lifts since 1968 Harding Steel Tri-Lift Density Security Economy Tri-Lift System Description System Description: The Harding Steel Tri-Lift parking system is a 4-post

More information

Applied. ATTENTION! 1200 lb WEIGHT LIMIT L-25 MINI TOWER INSTRUCTIONS REVISED: 10/24/2017 PROUDLY MADE IN THE U.S.A.

Applied. ATTENTION! 1200 lb WEIGHT LIMIT L-25 MINI TOWER INSTRUCTIONS REVISED: 10/24/2017 PROUDLY MADE IN THE U.S.A. 1 L-25 MINI TOWER ATTENTION! 1200 lb WEIGHT LIMIT BILL OF GOODS QTY: (1) 25' L-25 Mini Tower (1) HINGED BASE ASSEMBLY (1) 10 TOWER TRUSS (1) 7 TOWER TRUSS (1) 3 TOWER TRUSS (1) HEAD BLOCK (1) SLIDE BLOCK

More information

HSC EC 11-USA DETAN ROD SYSTEMS DT 14-US FAÇADE

HSC EC 11-USA DETAN ROD SYSTEMS DT 14-US FAÇADE HSC EC DETAN 11-USA ROD SYSTEMS DT 14-US FAÇADE HALFEN DETAN Rod Systems. The most Trusted Name. The most Elegant Application. With DETAN, architectural visions become a structural reality. DETAN Rod Systems

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories Wedge Lock Splice Plates Standard 4-hole pattern. Furnished in pairs, with hardware. One pair including hardware provided with each section. Boxed in pairs with hardware. For field installation drill 13

More information

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return CONTROLS Division of A-T Controls Heavy Duty Actuators Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to,600,000 in. lbs. Double Acting and Spring Return THD S E R I E S The Triac line

More information

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings Section 2 Cast & Wrought Grooved Fittings Shurjoint Grooved Fittings... 56 Flow Data / Friction Resistance... 56 Ductile Iron Grooved Fittings 7110 / 7111 / 7112 / 7113 Elbows... 57 7120 / 7135 / 7130

More information

SSS Square Straight Steel

SSS Square Straight Steel SSS Square Straight Steel Square Straight Steel Shaft One-piece construction Side, Tenon, or Pad mounting available Ground lug standard Galvanized anchor bolts and template included (4-bolt design) Base

More information

Commercial Grain Management Systems

Commercial Grain Management Systems Agri/Industrial Division Commercial Grain Management Systems Now with more roof options including peak load capacity of up to 50,000 lbs (22,680 kg)! MORE ROOF OPTIONS TO MEET YOUR SPECIFIC NEEDS! Chief

More information

KRANE-KING Jib & Gantry Cranes Gantries Free Standing Jibs Tension & Cantilevered Jibs Hoists

KRANE-KING Jib & Gantry Cranes Gantries Free Standing Jibs Tension & Cantilevered Jibs Hoists KRANE-KING Jib & Gantry Cranes Gantries Pages H.4 - H.17 Free Standing Jibs Pages H.18 - H.30 Tension & Cantilevered Jibs Pages H.31 - H.35 Hoists Pages H.36 - H.42 Index to Krane-King Jib & Gantry Cranes

More information

STANDARD PRACTICE INSTRUCTION

STANDARD PRACTICE INSTRUCTION STANDARD PRACTICE INSTRUCTION DATE: March 1, 2010 SUBJECT: Ladder Safety Program. REGULATORY STANDARD: 29 CFR 1910.25 Portable Wood Ladders. 29 CFR 1910.26 Portable Metal Ladders. 29 CFR 1926.1052-1060

More information

8400 Series Fiber Distribution System

8400 Series Fiber Distribution System 8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable

More information

Ford Passenger Cars Mustang II Independent Front Suspension Installation Instructions

Ford Passenger Cars Mustang II Independent Front Suspension Installation Instructions 1935-1948 Ford Passenger Cars Mustang II Independent Front Suspension Installation Instructions 1-866-925-1101 www.totalcostinvolved.com The installation of the Total Cost Involved's Mustang Independent

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System 1.01 Typical Installation Scope TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System Section 1- General Furnish labor, equipment, tools and material to install the PPB-300 Steel Piers as

More information

Support Equipment. In This Section Mobile Ingredient Bins H Kettle Drainer H Rack/Tray Carts H

Support Equipment. In This Section Mobile Ingredient Bins H Kettle Drainer H Rack/Tray Carts H H SUPPORT EQUIPMENT Support Equipment In This Section Mobile Ingredient Bins H-1...198 Kettle Drainer H-2...199 Rack/Tray Carts H-3...200 Tray, Cup or Glass Rack Carts H-3-B...201 Cup & Glass Rack Carts

More information

CHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70

CHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70 Proof Coil Chain Grade 28 Proof coil chain is suitable for use as towing chain, logging,fencing, trailer safety chain, boat anchors, security barriers or other general purposes where chain of high tensile

More information

,000 psi Minimum Yield Strength. 70,000 psi Minimum Tensile Strength

,000 psi Minimum Yield Strength. 70,000 psi Minimum Tensile Strength Commercial Bins/Silos Total Value. Total Systems. Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, GSI offers the strongest and heaviest gauge

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT

6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT 4096-349 March 27, 2012 REVISION J ASSEMBLY MANUAL 6-1/2 FT. x 6-1/2 FT. NON-PENETRATING MAST MOUNT General Dynamics 1500 PRODELIN DRIVE NEWTON, NC 28658 INSTALLATION INSTRUCTIONS J Revised tool list,

More information

Disassembly and pressure discharge of STABILUS products prior to disposal

Disassembly and pressure discharge of STABILUS products prior to disposal DE: X : X ES: X IT: X PR: X FR: X RO: X STABILUS products prior to disposal Revision no. Name / Date 534971 Kannewurf 05.02.2004 Revision no. Name / Date 537762 Kannewurf 05.07.2004 Revision no. Name /

More information

EXPANSION JOINT SELECTION GUIDE

EXPANSION JOINT SELECTION GUIDE EXPANSION JOINT SELECTION GUIDE The proper selection and application of an expansion joint is the determining factor in its operation and life. Improper selection and application will lead to problems

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

Shelving with Sloped Shelves

Shelving with Sloped Shelves Shelving with Sloped Shelves Rousseau shelving with sloped shelves provides superior-quality gravity flow storage that integrates perfectly with other products in our Spider family. This unique product

More information

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

StopGate TM Barrier Arm GENERAL SPECIFICATIONS StopGate TM Barrier Arm GENERAL SPECIFICATIONS I. GENERAL All StopGate Barrier Arms shall be designed and manufactured by Energy Absorption Systems, Inc., of Chicago, Illinois. II. DESCRIPTION OF SYSTEM

More information

WP Petroleum (Shanghai) Ltd. Tubular Handling Tools

WP Petroleum (Shanghai) Ltd. Tubular Handling Tools WP Petroleum (Shanghai) Ltd. Tubular Handling Tools Quality Assurance WP Petroleum (Shanghai) Ltd [WP] is firmly committed to providing high quality Tubular Handing Tools and services, which meet or exceed

More information

FULL COLOR TAB #16 TECHNICAL DATA

FULL COLOR TAB #16 TECHNICAL DATA FULL COLOR TAB #16 TECHNICAL DATA 276 General How Force Charts Weight Charts Seal Kits Conversion Charts TECHNICAL DATA How to determine the right cylinder size for the job. To determine what cylinder

More information

INSTALLATION INSTRUCTIONS AM rev. A

INSTALLATION INSTRUCTIONS AM rev. A INSTALLATION INSTRUCTIONS AM16629-1 rev. A READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. INTRODUCTION NOTE: Zebra technologies Corporation

More information

Rigid Entry Boots REB & RDEB. Installation Instructions

Rigid Entry Boots REB & RDEB. Installation Instructions Rigid Entry Boots REB & RDEB Installation Instructions Body Flat Gasket Clamp Plate Band Clamps Compression Nut Duct Boot (Included with RDEB) Warning Caution Follow all federal, state and local laws governing

More information

General Cable Support Information

General Cable Support Information General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices

More information

IBH. In-Between Handling Lift Trucks

IBH. In-Between Handling Lift Trucks IBH In-Between Handling Lift Trucks TECHNICAL DATA ELECTRICAL SYSTEM Model 1018: 12V, 105 A.H. rubber-clad industrial battery and built-in 8 amp. charger. Models 1518, 2018: 12V, 125 A.H. rubber-clad industrial

More information