1 Product Catalogue ETA C and D General The well-known ETA-pump on the bearing bracket C and D is constructed in accordance with DIN standard and completes the performance range up to max. 100 m3/hr (6600 Imp.g.p.m., 7900 USgpm). The graduation of pump sizes enables you to select a model of high efficiency and low absorbed horsepower under any set of operating conditions. Field of Application General water supplies for municipalities, industry and agriculture; water works, pressure boosting and irrigation plants; circulation of hot water, cooling water and oil; as condensate, building sites, and loading pumps etc. Design Horizontal single and two stage centrifugal pump with volute casing flanged onto the bearing bracket. Sizes /2 and 5-50/2 are two-stage. Overhung ral flow impeller equipped with balance holes for hydraulic balancing. Renewable casing wear rings and shaft protecting sleeves. Shaft Seal Uncooled soft-packed stuffing box up to 110 C (0 F) or cooled soft-packed stuffing box up to C (25 F). Other constructions are available which cater for special requirements. Uncooled mechanical seals up to C (25 F) max. may also be fitted. Nozzle Orientations Suction nozzle axial, discharge nozzle rally pointing upward; on sizes 200-, -29 and -35 tangentially left pointing upward. Other nozzle positions possible upon request. Flanges machined according to DIN 2533, NP 16, from size 200 upward according to DIN 2532, NP 10. Drive Direct drive by an electric motor, an internal combustion engine or a turbine via a flexible coupling. Bearings Axial and ral location by two oil lubricated deep groove ball bearings in the bearing pedestal. Grease lubrication on request
2 Materials of construction Part No. Part Designation Material combinations (01) (02) (03) (04) (05) (06) (07) (0) 101 Volute Casing JL Diffuser JL /2a Wear ring JL 1040 GCuSn 10 JL 1040 GCuSn 10 JL1040 GCuSn Pump Shaft 00M40Q 431S29 00M40Q 431S29 202/202a Impeller JL1040 GCuSn 10 JL 1040 GCuSn 10 JL1040 GCuSn 10 Shaft seal Packed gland Mechanical Packed gland Mechanical Bearing housing JL Stuffing box housing JL Gland JL Shaft Protecting sleeve JL SS JL 1040 GG-25 Selection Charts Selection chart at 1450 r.p.m m / / / ft m3/h
3 CAPACITY RANGE Casing Pressure: Cast-iron casings at temperatures up to 0 C at temperatures exceeding 0 C up to C 10 ats. gauge ats. gauge For higher pressures; attention is drawn to design in S.G. cast iron. Bearing Pedestal: C D Max. value N/n kw/rpm Corresponding maximum motor rating at speeds: 900 rev/min kw 1 rev/min kw Maximum Peripheral Speed: For cast iron impellers 40 m/sec (131 ft/sec) (meter in metres x R.P.M. x 3,14) 60 Use cast chrome-steel or bronze, for higher peripheral speeds. Temperature: Maximum operating temperature for all sizes: with standard stuffing box N with hot water stuffing box HW 105 C (uncooled stuffing box) C (cooled stuffing box) For higher temperatures, refer to S.G. cast iron construction. Lubrication: The pump shaft runs in two oil-lubricated ball-bearings. The bearings and the bearing bracket should be flushed with petrol or benzene while slowly rotating the shaft. After cleaning and complete removal of the cleaning agent, the bearing bracket should be filled with oil, Maximum and minimum oil level are indicated by marks on the dipstick. Only high-grade branded oils conforming to the following specifications should be used: Centistrokes Viscosity at 50ºC º Engler Specific gravity 20ºC max. Flash point minimum ºC Pour point below ºC Neutralization number max. Ash content % max. Bitumen content % up to 1500 rev/min over 1500 rev/min at low ambient temperature
4 Dimension Table Cooling water inlet and outlet connections for stuffing-box design HW, and sealing liquid or leakage connections for design VSM are 3/. Connection for other sealing liquid and flushing liquid VSH is 1/4 (see operating manual). Connections provided for: I Priming funnel, venting Size to /2 Size to -35 3/4 III Draining Size to /2 Size to -35 3/4 V Pressure gauge 1/2 VI Vacuum gauge 1/2 VII Oil-drain plug 3/ XII Oil-filling plug, dipstick 3/ XVI Leakage drain bearing pedestal C 3/4 Leakage drain bearing pedestal D 1 Size Bearing Pedestal C C C C C C C D D C D D D D DS D Pump a 1 b 1 b 2 f 1 g 1 h 1 h 1 h 2 m 1 m 1 m 3 m 4 n 1 n 1 n 2 n3 o 1 p 1 q 1 q 3 q 4 r 3 r 1 s 1 w
5 Size Tangential discharge dm 6 Shaft extension l u t Suction Flange Suction Flange Bolt Circle Raised Face Number Bolts Hole discharge Flange Discharge Flange Bolt Circle Raised Face Number Bolts Hole , , , , , , , , , , , , , , , , ETA: Flange size 100 to according to DIN 2533 NP 16 (EN PN16) Flange size 200 to - according to DIN 2532 NP 10 (EN PN16) ETA B: according to DIN 2533, nominal pressure 16 (EN PN16) For connection to pipelines with foreign flange standards (ASA pr BST) adaptor pieces or welded connecting flanges are fitted (acc. to DIN on the pump side). Number Of Stages: Pumps are single stage except the following sizes: Two stage pumps - ETA and 5-50 Shaft Protection: All sizes with bearing pedestals C and D have shaft sleeves of cast iron for standard design and stainless steel for mechanical seal design
6 ETA Size 0-40 Bearing Pedestal Pump a 1 b 1 b 2 f 1 g 1 h 1 h 1 m 1 m 1 m 2 n 1 o 1 p 1 q 1 q 2 r 3 BR s 3 w Size Tangential discharge dm 6 Shaft extension l u t Suction Flange Suction Flange Bolt Circle Raised Face Number Bolts Hole discharge Flange Discharge Flange Bolt Circle Raised Face Number Bolts Hole , Bearing Pedestal BRK Pedestal with no shaft protecting sleeve Number of stages Two stage pump - ETA 0-40/
7 Dimension Table ETA - B Size Bearing Pump Dimensions Shaft (pump) Pedestal a b1 b2 c d e f g h i k m o p q s y so dms l u t D DS
8 Part No. Designation 101 Volute casing 102a Suction cover 109 Diffuser 115 Bearing pedestal 2 Joint ring 2 a Joint ring 4 O ring 201 Shaft 202 Impeller 202 a Impeller,1st stage 211 Spacer sleeve 213 Shaft protecting sleeve 217 Impeller nut 222 Lock washer 241 Thrower 301 Cooling cover 344 Gasket.3 Flat gasket 407 Stuffing box gland 409 Deep groove ball bearing 4.3 Joint ring 4.4 Joint ring 426 Bearing end cover 426a Bearing end cover 432 Felt ring 433 Stuffing box packing 434 O-ring 437 Gasket 43 Gasket 439 Gasket 447 Lantern ring 456 Felt ring cover 471 Cover 472 Rotating seal ring for casing 474 Washer 475 Stationary seal ring 47 Right handed spring Set ring 556 Threaded plug/sealing liquid IX Cooling water / lnlet X Cooling water / Outlet XVI Leakage drain XX Sealing liquid / lnlet f Oil dipstick c Sealing liquid channel 1151:37/5 426a 213 XX 556 c f XVI a ETA with uncooled soft-packed stuffing box, construction N XX 556 c a a f a XVI a ETA, two-stage, with uncooled soft-packed stuffing box, construction N, sizes /2 and 5/
9 ETA ETA 0-40/ R.P.M. 46 Impeller mm Impeller outlet width 14-9 mm 47
10 ETA R.P.M. 4 Impeller mm Impeller outlet width 11 mm 47
11 ETA /2 4 Impeller 1st 330 mm Impeller outlet width 1st 15 mm Impeller 2nd mm Impeller outlet width 2nd 11 mm 1450 R.P.M. 49
12 ETA R.P.M. 50 Impeller mm Impeller outlet width 16 mm 49
13 ETA 5-50/2 Impeller 1st 330 mm Impeller outlet width 1st 22 mm 50 Impeller 2nd mm Impeller outlet width 2nd 16 mm R.P.M.
14 ETA R.P.M. 52 Impeller mm Impeller outlet width 20 mm 51
15 ETA R.P.M
16 ETA R.P.M. 54 Impeller mm Impeller outlet width 50 mm 53
17 ETA R.P.M. 54 Impeller mm Impeller outlet width 3 mm 55
18 ETA R.P.M. 56 Impeller mm Impeller outlet width 32 mm 55
19 ETA R.P.M. 56 Impeller 290/ / mm Impeller outlet width 0 mm 57
20 ETA R.P.M. 5 Impeller 330/330 - /210 mm Impeller outlet width 71 mm 57
21 ETA R.P.M. 5 Impeller mm Impeller outlet width 5 mm 59
22 ETA R.P.M. 60 Impeller mm Impeller outlet width 43 mm 59
23 ETA R.P.M. 60 Impeller 345/ /175 mm Impeller outlet width 97,5 mm 61
XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump
XFLO P U M P S XS SERIES Single Stage Double Suction Split Casing Centrifugal Pump General and Construction 1. Applications Waterworks, Irrigation, Drainage pumping stations, Power stations, Industrial
More informationVolute Casing Pump additional sizes to those of ISO 2858/EN 22858
Volute Casing Pump additional sizes to those of ISO 2858/EN 22858 CBTA 150200...350400 + 2 additional sizes 100160 and 125200 TECHNICAL DATA Output: up to 2200 m 3 /h Delivery head: up to 160 m Speed:
More informationNon-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h
Non-clogging Pump DBS 3216...30040 TECHNICAL DATA Output: up to 1200 m 3 /h Delivery head: up to 100 m Speed: up to 3600 rpm depending of the pump size and material execution Medium temperature: max. 110
More informationPA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.
END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 50HZ OR 60HZ PA SERIES APPLICATIONS PA Series pumps can be used for the following services in commercial, residential, agriculture, industrial,
More informationNon-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h. depending of the pump size and material execution
Non-clogging Pump DBS 3216...30040 TECHNICAL DATA Output: up to 1200 m 3 /h Delivery head: up to 100 m Speed: Medium temperature: max. 110 C Casing pressure: Shaft sealing: up to 3600 rpm depending of
More informationContents. Identification
Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions
More informationStandard SO according to DIN
Standard SO according to DIN 24.255 DESIGN FEATURES Design Features Horizontal centrifugal, single Stage pump. Spiral volute casing. Overhung on shaft impeller. Grease or oil lubricated antifriction bearing.
More informationVERTICAL IN-LINE PUMP
VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line
More informationBEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data
Type series booklet CTI-2000/00 [09-2010] BEV Deep well vertical pumps 1. Fields of Application BEV are vertical multistage centrifugal pumps designed for deep well, ditches and tanks to pump clean liquids
More informationTKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion
TKL Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump Experience In Motion 1 The total cost of a pump includes not only purchase price, but cost of operation: power costs, reliability, ease
More informationBoiler Feed Booster Pump YNK. Type Series Booklet
YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any
More informationHigh-pressure pumps Series HP49
High-pressure pumps Series HP49 www.andritz.com/pumps General Description / Application Multi-stage high pressure pumps for water supply, irrigation and industrial applications, for hot and cold water
More informationData sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6
Data sheet Item no.: Page: 1 / 6 Operating data Operating data determined for maximum inlet pressure Pumped medium Water Clean water Not containing chemical and mechanical substances which affect the materials
More informationHYDRO-TITAN. Heavy duty back pullout water & process liquid pumps
HYDRO-TITAN Heavy duty back pullout water & process liquid pumps Positioned for Reliability The total cost of a pump includes not only purchase price, but cost of operation: power costs, reliability, ease
More informationSIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.
Modular multistage pumps SIHI multi Type MSC Description The SIHI multi MSC range of horizontal, ring-section multistage pumps have been designed for long-term reliability when pumping high pressure liquids.
More informationNorm-Centrifugal Pumps PN 10
Norm-Centrifugal Pumps PN 10 Pump dimensions acc. to DIN EN 733 with additional sizes Technical requirements acc. to DIN ISO 9908 Application For pumping pure water, industrial water, sea water, condensate,
More informationSide channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description
Side channel pumps PN 16 Self-priming centrifugal pumps SOH - SOHB Technical description Operating data Design Industries Media pumped: Nominal diameter: 1-1 1 /2 Flow rate: 0.3-7.5 m 3 /h Pump head: 5-155
More informationAxially split volute casing pumps. Applications. Bearings. Shaft seal. Operating data
Type series booklet 1385.52/3--10 RDLV Axially split volute casing pumps Applications Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems, fire fighting
More informationSIHI multi. Modular multistage pumps. Type MSL, MSM. Description. Construction. Applications. Technical Data. Options
Modular multistage pumps SIHI multi Type MSL, MSM Description SIHI multi pumps are horizontal multistage centrifugal pumps of ring-section design, which meet the technical requirements of ISO 5199 / EN
More informationSide channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description
Side channel pumps PN 16 Self-priming centrifugal pumps SOH - SOHB - SOHM Technical description ATEX certified The SOH side channel pump models are available in a variety of designs. Design base plate
More informationData sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.
Data sheet Item no.: 3700 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 415.38 m ³/h Clean water Actual developed head 57.81 m Not containing chemical and Efficiency 82.3 % mechanical
More informationBearings. Shaft seal. Materials
Type series booklet 1385.51/3--10 RDL Axially split volute casing pumps Applications Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems, fire fighting
More informationNTT CENTRIFUGAL PUMPS TO EN733 (DIN 24255) FOR HEAT TRANSFER OILS UP TO 350 C
FOR HEAT TRANSFER OILS UP TO 350 C WE HAVE ALL THE TICKS Version 1 - NTT: Rapid Allweiler Pumps Whilst all care has been taken to ensure the accuracy of the information contained in this brochure was correct
More informationRWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data
Type series booklet CTI-4900/01 [04-2012] RWCP, RWCN Vertical pumps for tanks for loaded liquids 1. Fields of Application RWCP and RWCN are vertical, centrifugal pumps designed for wells, ditches and tanks.
More informationWaterflo WF Series Back pull-out End Suction Centrifugal pump
08 Waterflo WF AKAY INDUSTRIES AKAY WATERFLO WF SERIES Akay WATERFLO WF Series range fully complies to both performance and dimensional standards to the international Standard DIN 24255 Stuffing Box Standard
More informationElite. KSB Australia Pty Ltd. Centrifugal Pump
Type Series Booklet Elite Centrifugal Pump Application The Ajax Elite centrifugal pump is suitable for handling water and similar liquids mainly used in the following applications. -Water Supply -Air conditioning
More informationNC State University Design and Construction Guidelines Division 23 Hydronic Pumps
1.0 Purpose A. The following guidelines apply to the selection of pumps primarily for circulating water. It is the goal of NC State to purchase pumps that are selected to provide a long service life, minimal
More informationNormpumpen nach DIN EN 733 einschl Standard horizontal pumps to DIN EN 733 NORMA J ( ) PUMPS I MOTORS I SYSTEMS I SERVICES
NORMA J ( ) PUMPS I MOTORS I SYSTEMS I SERVICES Introduction Pumps of the Norma J ( ) Series are horizontal volute casing centrifugal end suction pumps with Back Pull-out feature. Principal dimensions
More informationKSB RPH-V. Process pumps. 3. Designation. 1. Application. 2. Design. 4. Operating Data. to API 610, 11th edition and ISO 13709
Type Series Booklet 1316.56/04-EN (A1316.0.2E/8) KSB Process pumps to API 610, 11th edition and ISO 13709 1. Application pumps are mainly used in refineries as well as in chemical and petrochemical plants.
More informationGIS/ GISO Series End Suction Pumps TECHNICAL BULLETIN
GIS/ GISO Series End Suction Pumps TECHNICAL BULLETIN Goulds Water Technology is renowned for manufacturing the highest quality pumping equipment utilizing the best engineering practices available worldwide.
More informationVolute Casing Centrifugal Pumps PN 16 for Heat Transfer Oils up to 350 C Series NTT Pump dimensions acc. to DIN EN 733 with additional sizes
Volute Casing Centrifugal Pumps PN 16 for Heat Transfer Oils up to 350 C Series NTT Pump dimensions acc. to DIN EN 733 with additional sizes Application For handling organic heat-transfer oils in heat
More informationData sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.
Data sheet Page: 1 / 5 Operating data Requested flow rate 160.00 m³/h Actual flow rate 159.85 m³/h Operating data determined for maximum inlet pressure Actual developed head 20.96 m Requested developed
More informationILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.
Type series booklet CTI-2600/04 [04-2017] ILN, ILNC In Line vertical pumps ILN single suction ILN double suction ILNC sizes 65/ to 250/... sizes 300/ all sizes 1. Fields of Application Suitable for a wide
More informationHORIZONTAL SPLIT CASING PUMPS TYPE : UP / UPL / UPH
HORIZONTAL SPLIT CASING PUMPS TYPE : UP / UPL / UPH HORIZONTAL AXIALLY SPLIT CASING PUMPS Range : Delivery size upto 1220 mm Capacity up to 24,000 m³/hr Head up to 180 meters Applications : Suitable for
More informationCasing. Impeller. Gland. Shaft. Bearing Bracket. Support Foot RANGE APPLICATIONS
Casing Impeller Gland Shaft Bearing Bracket Support Foot RANGE APPLICATIONS Delivery size : up to 150 mm Capacity Head 3 : up to 550 m /hr : up to 100 metres Circulation of water in industries, Air-conditioning
More informationSide Channel Pumps Self-priming, segmental type with verly low NPSH
Side Channel Pumps Self-priming, segmental type with verly low NPSH CEH Sizes 1201 6108, 1202/5 6108/5, 1202/7 6107/7 Technical data Capacity: Delivery head: Speed: max. 35 m³/h max. 354 m max. 1800 1/min
More informationabcdef EUseries EN733/DIN End Suction Centrifugal Pumps where innovation flows SNG
abcdef SNG 09 where innovation flows EN7/DIN 22 End Suction Centrifugal Pumps www.euroflopumps.com Coding System Eg. EU 2 / 1 MBC DB EUM / 2 MBC A2-01 Series EU = Bareshaft pumps EUM = Monobloc pumps X
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please
More informationISO 2858 Back Pullout End Suction Centrifugal Pumps
ISO 2858 Back Pullout End Suction Centrifugal Pumps Back Pullout End Suction Centrifugal Pumps Applications: Irrigation Water transfer Building Services Pressure Boosting Mining HVAC Features: Designed
More informationANSI, CLT & CLB CHEMICAL PROCESS PUMPS
ANSI, CLT & CLB CHEMICAL PROCESS PUMPS RAPID ALLWEILER PUMPS HEAD OFFICE WE HAVE ALL THE TICKS DEEP APPLICATION KNOWLEDGE TAILOR MADE PUMPING SOLUTIONS STATE OF THE ART TRAINING CENTRE LEADING PROVIDER
More informationHorizontal Double Suction Volute Pump Type CN. Pipe line
PUMP Horizontal Double Suction Volute Pump Type APPLICATIONS Buildings Irrigation Water supply Drainage Water circulation Fire fighting Air conditioning Water supply Drainage Waterworks Water intake Booster
More informationGeneral Catalog. A New Vision for Quality Pumps. General Catalog
General Catalog A New Vision for Quality Pumps General Catalog 2 Tru20 is committed to only the highest quality pumping products. We produce a tremendous range of water and process pumps in order to serve
More informationHigh-pressure pumps Series HP45
High-pressure pumps Series HP45 www.andritz.com/pumps General Description / Application Multi-stage high pressure pumps for water supply, irrigation and industrial applications, for hot and cold water
More informationEtanorm SYT Type Series Booklet
Thermal Oil / Hot Water Pump Etanorm SYT Type Series Booklet Legal information/copyright Type Series Booklet Etanorm SYT All rights reserved. The contents provided herein must neither be distributed, copied,
More informationCentrifugal End Suction Fire Pumps
Centrifugal End Suction Fire Pumps 1 Centrifugal End Suction Fire Pumps Product Overview American-Marsh Model FP-REF End Suction pumps are used in a variety of fire protection services every day. These
More informationEUF/EUFS series. Fire Pump PSB Listed according to CP52(Singapore)
ANNEX 1: SPECIMEN OF LOGO and MARK A) SETSCO (Registered) Logo where innovation f l ow s B) SETSCO Mark for Ready-Mixed Concrete Cert No: RMC-YYYY-XXX-A C) SETSCO Mark for Fire Safety Products Fire Pump
More informationSide Channel Pumps Self-priming, segmental type
Side Channel Pumps Self-priming, segmental type AKH 1101 6103 Technical data Capacity: from 0,2 up to 35 m³/h Head: from 6 up to 144 m Speed: 1450 rpm (max. 1800 rpm) Temperature: max. 120 C Casing pressure:
More informationSide channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH
Side channel pumps ADH/CDH 0801... 2504 AEH 0805... 0808 TECHNICAL DATA Capacity: Head: Speed: max. 7,2 m³/h max. 400 m max. 3000 rpm Temperature: max. 120 C Casing pressure: Shaft sealing: PN 25 for ADH/CDH
More informationINVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data
Type series booklet CTI-0300/03 [05-2012] INVCP, INVCN Vertical pumps for tanks 1. Fields of Application INVCP pumps are used for organic and inorganic liquids in water services and different industries.
More informationSILI PUMP, Your reliable one-stop supplier of marine pumps.
SILI PUMP, Your reliable one-stop supplier of marine pumps. Shanghai SILI PUMP Industry Co., Ltd. Add: No.128 Jinyuan Road, 201518, Shanghai, China (Jinyuan Industry Area) Tel: 0086-21-39109967, fax: 0086-21-39109967
More informationMZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data
Type series booklet CTI-1700/00 [12-2008] MZ, MA Liquid ring pumps 1 Fields of application Multi-stage, horizontal liquid ring pumps, with self-priming capacity. MZ and MA pumps are used for pumping of
More informationSIHI prime - Side Channel Pumps Self-priming, segmental type
SIHI prime - Side Channel Pumps Self-priming, segmental type AKH-X 1201 3606 TECHICAL DATA Capacity: Delivery head: Speed: from 0.4 up to 7.5 m³/h from 10 up to 242 m 1450 rpm (max. 1800 rpm) Temperature:
More informationES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS
ES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS Conforms to ISO 2858 Conforms to ISO 5199 Optimized for capacity Efficiency as per Hydraulic Institute & Europump Norms Many product variants -
More informationKIRLOSKAR END SUCTION PUMPS-TYPE DB/DBHS. Description. Cut-sectional View. Shaft :
KIRLOSKAR END SUCTION PUMPS-TYPE DB/DBHS Description Range : Delivery size up to 150 mm Capacity up to 550 m 3 /hr Head up to 100 metres Applications : Suitable for Circulation of Water in Industries,
More informationSKM-D. Multistage Centrifugal Pumps TS EN ISO 9905 ST 02/ EN ISO 9001
Multistage Centrifugal s KM T EN IO 9905 T 02/04.033 EN IO 9001 General information KM Handled Liquids : KM pumps are suitable for clean liquids with low viscosity. Technical ata ischarge Nozzle Range
More informationCompany name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017
Position Qty. Description 1 NB 1-31/29 A-F2-B-E-BAQE Phone: 4 84 61 Date: 13/3/217 Product No.: On request Non-self-priming, single-stage, centrifugal volute pump designed according to ISO 199 with dimensions
More informationDesign Characteristics. Aplicaciones
Design Characteristics Single stage centrifugal. Casing axially split. Double entry impeller. Bearings on both sides of impeller. Suction and discharge branches located in lower casing. Características
More informationGrupa Powen-Wafapomp SA. Pumps for Power and Heat Supplying Industries catalogue
0 Grupa Powen-Wafapomp SA Pumps for Power and Heat Supplying Industries 2017 catalogue Contents 2 Basic pumps Supply pumps Z YS 4 10 Condensate pumps K i WK 20 Cooling water pumps D P 26 32 Hot water pumps
More informationRDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F
Type Series Booklet 1387.5/2--10 RDLO / RDLO V Axially Split Volute Casing Pumps Fields of Application Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems,
More informationData sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m
Data sheet Item no.: 2600 Page: 1 / 5 Operating data Requested flow rate 40.00 m ³/h Actual flow rate 40.00 m ³/h Requested developed head 68.00 m Actual developed head 68.00 m Pumped medium Water Efficiency
More informationSMD axially split casing, double suction pump
SMD axially split casing, double suction pump Main applications SMD single stage, double suction, axial split casing pumps are designed to meet the needs of the water market for a wide range of raw, clean,
More informationHORIZONTAL SPLIT CASING PUMP
HORIZONTAL SPLIT CASING PUMP HORIZONTAL PUMP CONSTRUCTION MBH Horizontal Split Casing Pumps - a new concept for better performance and higher efficiencies. For greater interchangeability and ease of maintenance,
More informationVertical multistage centrifugal pumps in ring-section design
Vertical multistage centrifugal pumps in ring-section design Vertical multistage centrifugal pumps in ring-section design PUMP DESIGN Multistage centrifugal pumps in ring-section design, radially split,
More informationGoulds Small Capacity Double Suction Pump
Goulds 3410 Small Capacity Double Suction Pump 3410 Double Suction Pumps Designed for a Wide Range of Industrial, Municipal, Capacities to 7,000 GPM (1591 m3/h) Heads to 550 feet (168 m) Temperatures to
More informationHigh-Pressure Centrifugal Pumps
High-Pressure Centrifugal Pumps L LV Application For handling fluids which do not contain any abrasive particles nor chemically attack the pump materials. Main fields of application In water supply, booster,
More informationData sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.
Data sheet Item no.: 1900 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 72.19 m ³/h Operating data determined for maximum inlet pressure Actual developed head 70.26 m Clean water Efficiency
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationPROJ. NO SECTION HYDRONIC PUMPS
SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationHeat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet
Heat Transfer Fluid / Hot Water Pump HPK-L Type Series Booklet Legal information/copyright Type Series Booklet HPK-L All rights reserved. The contents provided herein must neither be distributed, copied,
More informationHORIZONTAL MULTI STAGE PUMPS
HORIZONTAL MULTI STAGE PUMPS APPLICATIONS Water supply Hot/cold water Sprinklers Agriculture Construction Factories Mines Boiler feed Other general high pressure services *Please choose the model, referring
More informationG&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS
TECHNICAL Brochure BAC8 Series A-C 8 SPLIT CASE PUMPS TABLE OF CONTENTS Useful Pump Formulas 2 Performance Curves 3-5 Materials of Construction (Standard) 6 Materials of Construction (Optional) 7 Pump
More informationIndex - Section 14 End Suction Pump Semi-Open Impeller
Index - Section End Suction Pump Semi-Open Impeller ITEM S Product Numbering System...1 Typical Architects / Engineers Specifi cations - Series 4000...2 Seal Application...3-4 Technical Charts...5-6 Pump
More informationN, N4. End-Suction Centrifugal Pumps standardized EN 733
, Construction Single-stage end-suction centrifugal pumps, with bearing bracket. ominal duty points and main dimensions in accordance with E 7. Back Pull-Out construction, for simple and quick dismantling
More informationCPS. Horizontal Split Case Centrifugal Pump
CPS Horizontal Split Case Centrifugal Pump CPS Series pumps, are single-stage double suction split case centrifugal pumps designed for applications of clean water or similar liquids without solids in water
More informationINDUSTRY APPLICATION. S -pumps are used in: Industry Waste treatment Environment protection Construction industry Civil engineering
INDUSTRY APPLICATION Self-priming centrifugal pumps of type S are used for pumping clean and contaminated liquids containing solids. The special design makes them suitable also for abrasive liquids. S
More informationData sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
More informationBulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support
Bulletin C 1.4.43 Dean Pump Division Heavy Duty, High Temperature Process Pumps R4140 Telescoping Guard R4140 C-Face Motor Support Dean Pump Series R Centrifugal Process Pumps Capacities to 5000 GPM (1135
More informationSMN Double-Suction Axially Split Pump
SMN Double-Suction xially Split Pump motralec 4 rue Lavoisier. Z Lavoisier. 95223 HERBLY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com
More informationAxial geteilte Spiral-gehӓusepumpen Axial split case pumps ASE ( ) PUMPS I MOTORS I SYSTEMS I SERVICES
ASE ( ) PUMPS I MOTORS I SYSTEMS I SERVICES Introduction RITZ ( ) ASE axial split case pumps has been developed for wide range of application benefiting both the industrial users and the municipality.
More informationVolute pumps for heat carrier oils up to 350 C. SIHI SuperNova ZTND TECHNICAL DATA. Temperature: max. 350 C Casing pressure: PN 16
Volute pumps for heat carrier oils up to 350 C SIHI SuperNova ZTND 032-125... 200-500 TECHNICAL DATA Output: Delivery head: Speed: max. 0 m³/h max. 95 m max. 3600 rpm Temperature: max. 350 C Casing pressure:
More information855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps
855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps Technical Specification Pages This page left intentionally blank. 1.0 Overview. The 855 Series is Carver s offering specifically designed to
More informationTECHNICAL BROCHURE BMPVN MPVN HIGH PRESSURE MULTI-STAGE PUMPS
TECHNICAL BROCHURE BMPVN MPVN HIGH PRESSURE MULTI-STAGE PUMPS A FULL RANGE OF PRODUCT FEATURES Performance Range: Capacities up to GPM ( m /h) Head up to feet ( m) Maximum speed up to RPM Sizes: From "
More information1100 Series Multi-Stage Vertical Turbine Pumps
1100 Series Multi-Stage Vertical Turbine Pumps Capacities to 40,000 GPM Heads to 1,500 Feet Temperatures to 200 F Water Lubricated Open Lineshaft Vertical Hollow Shaft Motor The vertical hollow shaft motor
More informationVSC /VSCS Pumps Technical Brochure
VSC /VSCS Pumps Technical Brochure BX-4C VSC/VSCS Construction Materials STANDARD SEAL CONFIGURATION PART NAME STANDARD CONSTRUCTION ASTM NO. Casing Cast iron A159 Class G0 Volute cover plate (Outboard)
More informationJansen Pompentechniek T: +31(0) E:
1 1 VOGEL - Pumps with Channel Type Impeller, Design KS Capacity up to 500 m 3 /h (2200 USgpm) Head up to 45 m (150 feet) Speed up to 1450 min -1 (1450 r.p.m.) Sizes: DN 65 up to DN 150 (21/2 up to 6 )
More informationZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps
ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps Main Applications Features and Benefits ZPP and Z22 double suction axially split single stage centrifugal pumps are used for demanding
More informationSJP Vertical Propeller Pumps
Sulzer Pumps SJP Vertical Propeller Pumps The Heart of Your Process Sulzer Pumps Sulzer Pumps is a world leader in reliable products and innovative pumping solutions. Our advanced research and development,
More informationVolute pumps for hot water up to 230 C
Volute pumps for hot water up to 230 C SIHI SuperNova ZEND 031125... 125250 TECHNICAL DATA Output: Delivery head: Speed: max. 600 m³/h max. 90 m max. 3600 rpm Temperature: max. 230 C (1) Casing pressure:
More informationPUMP TYPE Single stage, axially split volute casing pump with double entry radial impeller, for horizontal installation.
SKD SERIES PRODUCT DESCRIPTION AND TECHNICAL DATA PUMP TYPE Single stage, axially split volute casing pump with double entry radial impeller, for horizontal installation. APPLICATION Water supply systems,
More informationPN 16/PN 25 Volute Centrifugal-Pumps for Heat Transfer Media Thermal Oil up to 400 C Hot Water up to 207 C
PN 16/PN 25 Volute Centrifugal-s for Heat Transfer Media Thermal Oil up to 00 C Hot Water up to 7 C Series NTWH/CTWH Series NBWH/CBWH Series NIWH/CIWH Application For circulating heat transfer media such
More informationCombiNorm. Centrifugal pump according to EN 733 (DIN 24255)
CombiNorm Centrifugal pump according to EN 733 (DIN 242) The SPX FLOW Johnson Pump Combi system is a modular programme of single stage centrifugal pumps with a high degree of interchangeability of parts
More informationBulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs
Bulletin BX-1H Bell & Gossett Series HSC-S Pumps Technical Bulletin Part of the Bell & Gossett Equipment Selection Programs TABLE OF CONTENTS Useful Pump Formulas...............................................
More informationVolute pumps for hot water up to 207 C
Volute pumps for hot water up to 207 C SIHI SuperNova ZDND 032160... 250 TECHNICAL DATA Output: Delivery head: Speed: max. 600 m³/h max. 90 m max. 3600 Temperature: max. 207 C Casing pressure: PN 25 Shaft
More informationType ZEND. SIHI Model: ZEND / ZDND / ZHND Hot Water Transfer Pumps Product Reference Manual. Experience In Motion. FPD-xxxx
Type ZEND SIHI Model: ZEND / ZDND / ZHND Hot Water Transfer Pumps Product Reference Manual FPD-xxxx Experience In Motion Volute pumps for hot water up to 230 C SIHI SuperNova ZEND 031125... 125250 TECHNICAL
More informationVolute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M
Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive Series CNH-M Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service
More informationProcess Pump RPH. Type Series Booklet
Process Pump RPH Type Series Booklet Legal information/copyright Type Series Booklet RPH All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationSingle-stage centrifugal pumps to standards en 733 (nfe 44111) and iso 5199 Industry Agriculture - Heating
OPERATING LIMITS Flow up to : m /h Head up to : mce Service pressure up to : Jusqu à bar* Temperature range : - à +7 C hot water up to : + C * depending on model NOLH Single-stage centrifugal pumps to
More informationPTB GLV. Vertical Centrifugal Pump
Vertical Centrifugal Pump GLV Application Vertical centrifugal pumps, approved in design and certified, are applied as tank installation pumps in areas with explosion hazard. Equipped with special safety
More informationHigh Temperature Chemical Process Inline Pumps
Bulletin C-1.2.21. Dean Pump Division High Temperature Chemical Process Inline Pumps Series DL Series DL High Temperature Chemical Process Inline Pumps Capacities to 6 GPM (182 m 3 /hr) Heads to feet (167
More informationMULTISTAGE PUMPS TYPE RKB
MULTISTAGE PUMPS TYPE RKB MULTISTAGE PUMPS-TYPE : RKB Description Range : Delivery size upto 250mm Capacity up to 850 m³/hr Head up to 850 m Applications : Sprinkler irrigation, Fire Fighting, Water supply
More information