Blow Type Application Examples

Size: px
Start display at page:

Download "Blow Type Application Examples"

Transcription

1 Blow Type pplication Examples Removal of static charges when taking out or storing wafers voids electrostatic discharging when taking wafers out of their cassettes, and prevents the stored wafers from being attracted to the transfer arm. Removal of static charges when conveying wafers Prevents dust from being attracted to the surface of wafers. Prevents the internal patterns from being damaged. Use -shaped bar nozzle Use blow type ionizer with straight bar nozzle. rm Removal of static charges on parts when carried by a parts feeder Static electricity is generated due to friction of parts while the parts feeder conveys them, and the parts stick to feeder s surface. Use the blow type ionizer to prevent parts from being sticked caused by static electricity. lso, simultaneous use with a fan type is effective against the static electricity removal. Removal of static charges on wafers Use blow type ionizers with shower nozzles that provides Ionized air flow with a wide angle to remove static charges on wafers. Use straight bar nozzle or shower nozzle. Removal of static charges and particles on CDs and DVDs Use -head types with bender nozzles to remove static charges and particles on CDs and DVDs from both sides. Removal of static charges on wrap film Use blow type Ionizers with U-shaped bar nozzles in confined space to remove static charges on both sides of the wrap film. Bender nozzle CDs and DVDs, etc. u

2 Removal of static charges on devices carried by pallets Use blow type Ionizers with straight bar nozzles to remove static charges on a wide carrying pallet. Removal of static charges in printing process Use -head type Ionizers with bender nozzles. Prevents faulty printing caused by static charges in ink jet printing process. Bender nozzle BOW TYPE Use straight bar nozzles at two places to remove static charges. Removal of static charges in bottles (Removal of dust) Use a spiral bar nozzle to remove static charges inside a bottle. Blows ionized air from the tip. Removal of static charges on electronic parts Very low generation of electrical noise No damage to a device caused by induction electric field by the discharging needle. Removal of static charges with pin point accuracy (It is possible to place the nozzle close to a device by using the tube.) Note: Select a tube in accordance with the degree of tube flexibility. Spirally blows ionized air from the side surface of the bar. Removal of static charges on glass substrate Use -head type Ionizers with two straight bar nozzles to remove static charges on FPD glass. Removal of static charges in pipes ( or less) By inserting the tube inside a pipe enables removal of static charges. i

3 Select the nozzle for your application Shower nozzle Flat nozzle Blows ionized air at or 9 angles Blows ionized air at 9 angle, suitable for removal of static charges over relatively wide area. 9 or 9 Use of two straight bar nozzles Straight bar nozzle Removal of static charges from both sides of film simultaneously. Removal of static charges over a wide area. types of bar nozzles are applicable for to mm ionized air coverage. -shaped bar nozzle U-shaped bar nozzle Space saving and suitable for locations where straight bar nozzles can't reach. types of -shaped bar nozzles are applicable for and mm ionized air coverage. Removal of static charges from both sides simultaneously up to mm wide film. Free-mounting -shaped bar nozzle Enables the bar rotation to change the direction of the ionized air flow outlet. It is applicable for and mm ionized air coverage. Combining various nozzle units with bender nozzles Combining various nozzle units with the flexible tube enables static charge removal for various applications. When using the bender shower nozzle unit or 9 Note: Nozzle units can be only attached to the nozzles with a bender nozzles (DTRY-NZR ND and DTRY-NZ ND) For installation of nozzle unit, see Rotate the bar in the desired direction. o

4 Specifications Blow Type and Compact Blow Type DTRY-EB DTRY-EB DTRY-E Item (Main Unit for -head Type) (Main Unit for -head Type) (Main Unit for -head Type) Power supply VDC % Consumption current m pprox. Output voltage kv pprox. (High frequency type) While power is supplied, power indicator ED (Green) turns on. When an abnormal discharge occurs, the abnormality indicator ED (Red) turns on. Power safety circuit The contact point output NO/NC is selectable when an abnormal discharge occurs. Note The contact point output NO/NC is selectable when an ( DVC m Max.) abnormal discharge occurs. Note ( DVC m Max.) Outer dimensions mm 9()(W)(H) (Main unit only) 9()(W)(H) (Main unit only) ()(W)7(H) (Main unit only) Mass g[oz.] 9 [.7] (Main unit only) [.] (Main unit only) [.] (Main unit only) Ion balance Note V Ozone generation amount ppm.7 or less (When measured at mm apart from the nozzle outlet with a standard nozzle and. MPa air at primary side.) Media Note ir (vapor- and oil-removed clean air) Supply air flow rate R/min(NR) pprox. (with DTRY-NZRNS nozzle and. MPa air at primary side, per head.) pprox. (with DTRY-NZNS nozzle and. MPa air at primary side) Operating air pressure range Operating ambient temperature ccessories Blow Type MPa[psi.] C[ F] Notes : For output of abnormality output contact point, see : The ion balance value of the DTRY-E is the value when the air flow rate is R/min(NR). : lways turn on the power supply with supplying air. Remarks : When using two or more Ionizers, mount them at least mm apart. Closer mounting may cause a detrimental effect or detrimental ion balance. : Ion balance is measured by in-house test standard. Consult us for details. Graphs of Static Charge Removing Characteristics (when using the standard nozzle) See for Graphs of Static Charge Removing Characteristics when using the other nozzles. DTRY-EB Static Charge Removing Characteristics obtained when the Standard Nozzle is used Nozzle DTRY-NZRNS.. [] (with DTRY-NZRNS nozzle).. [7] (with DTRY-NZRS nozzle).. [7] (with conductive urethane, Teflon or silicone tube).. [7] (with DTRY-NZRNDND nozzles).. [7] (with DTRY-NZRSW nozzle).. [7] (with DTRY-NZRSW nozzle).. [77].. [7] (with DTRY-NZRFT nozzle).. [7] (with DTRY-NZRSP nozzle).. [7] (with DTRY-NZRBB nozzles).. [7] (with DTRY-NZR nozzles).. [7] (with DTRY-NZRU nozzle).. [7] (with DTRY-NZRFMTFMT nozzles) [] indoor (avoid a place subject to dew condensation) pc. power and signal cable ( m), pc. ground wire ( m), and pc. contact point selector protection sticker Measured distance: mm Measured distance: mm Measured distance: mm Compact Blow Type DTRY-E Static Charge Removing Characteristics obtained when the Standard Nozzle is used Nozzle DTRY-NZNS pc. power and signal cable ( m), pc. bracket, and pc. contact point selector protection sticker Measured distance: mm Measured distance: mm Measured distance: mm BOW TYPE Item Controller Power supply Consumption current Outer dimensions Mass Media Max. flow rate Operating pressure adjusting range Proof pressure m mm R/min(NR) Filtering particle diameterm Filter capacity Filtering efficiency % Operating ambient temperature C[ F] ccessories g[oz.] MPa[psi.] MPa[psi.] MPa psi. DTRY-EC VDC % () (W) (H) (Main unit only) [9.] (Main unit only) ir (.7 MPa at primary-side pressure and. MPa at secondary-side pressure).. [7]. [] [] indoor (avoid a place subject to dew condensation) pc. connection cable between controller and Ionizer (. m) Note: Pay attention to the maximum flow rate and operating pressure adjusting range when using the controller. It may cause a shortage of the flow rate compared to the one obtained not using the controller. Remark: The Ionizer is a stand-alone unit. However, the use with the controller enables control of both power supply and air.!

5 Order code BOW TYPE Main Unit -head type DTRY-EB -head type DTRY-EB Caution The main unit cannot be operated alone. lways use it with a nozzle. Caution The discharging needles are covered with cover caps for protection. Remove the cap before installing the nozzle. Nozzles for Blow Type Standard nozzle DTRY-NZRNS Bender nozzles DTRY-NZRND ( mm) DTRY-NZRND ( mm) DTRY-NZRND ( mm) DTRY-NZRND ( mm) DTRY-NZRND ( mm) Flat nozzle DTRY-NZRFT Straight bar nozzles DTRY-NZRB (Nominal size: mm) DTRY-NZRB (Nominal size: mm) DTRY-NZRB (Nominal size: mm) DTRY-NZRB (Nominal size: mm) DTRY-NZRB (Nominal size: mm) Free-mounting -shaped bar nozzles DTRY-NZRFMT (Nominal size: mm) DTRY-NZRFMT (Nominal size: mm) U-shaped bar nozzle DTRY-NZRU Stainless steel pipe nozzle ( mm) DTRY-NZRS Shower nozzles DTRY-NZRSW ( type) DTRY-NZRSW (9 type) -shaped bar nozzles DTRY-NZR(Nominal size: mm) DTRY-NZR(Nominal size: mm) Spiral bar nozzle DTRY-NZRSP Option Bracket (For straight bar nozzle) DTRY-EQ Caution: Dedicated for the blow type Common Options for Blow Type and Compact Blow Type Bender shower nozzle units DTRY-DN-SW ( type) DTRY-DN-SW9 (9 type) Conductive urethane tube ( mm) DTRY-DN-U Silicone tube ( mm) DTRY-DN-S! Bender flat nozzle unit DTRY-DN-FT Bender bar nozzle units DTRY-DN-B (Nominal size: mm) DTRY-DN-B (Nominal size: mm) Teflon tube ( mm) DTRY-DN-F Outer diameter: Inner diameter: Outer diameter: 7 Inner diameter: Outer diameter: 7 Inner diameter: Note : The tube is a consumable item; periodic replacement is required. Note : The DTRY-DN-S and DTRY-DN-F cannot be used for the earlier type standard nozzles DTRY-NZRS and DTRY-NZS. Remarks : Use Teflon tube for endurance-oriented, and silicon tube for flexibility-oriented. Remarks : m or m roll of conductive urethane tubes is available. Order code: U-B ( m) Order code: U-B- ( m)

6 COMPCT BOW TYPE Main Unit -head type DTRY-E BOW TYPE Caution The main unit cannot be operated alone. lways use it with a nozzle. Caution The discharging needle is covered with the cover cap for protection. Remove the cap before installing the nozzle. Nozzles for Compact Blow Type Standard nozzle DTRY-NZNS Bender nozzles DTRY-NZND ( mm) DTRY-NZND ( mm) DTRY-NZND ( mm) DTRY-NZND ( mm) DTRY-NZND ( mm) Flat nozzle DTRY-NZFT Straight bar nozzles DTRY-NZB (Nominal size: mm) DTRY-NZB (Nominal size: mm) DTRY-NZB (Nominal size: mm) DTRY-NZB (Nominal size: mm) DTRY-NZB (Nominal size: mm) Free-mounting -shaped bar nozzles DTRY-NZFMT (Nominal size: mm) DTRY-NZFMT (Nominal size: mm) U-shaped bar nozzle DTRY-NZU Stainless steel pipe nozzle ( mm) DTRY-NZS Shower nozzles DTRY-NZSW ( type) DTRY-NZSW (9 type) -shaped bar nozzle DTRY-NZ(Nominal size: mm) Spiral bar nozzle DTRY-NZSP Caution Dedicated use for DTRY-E. These nozzles cannot be used for DTRY-CE. Conductive urethane tube holder DTRY-NZR For application examples, refer to page i Caution: Dedicated use for conductive urethane tube C adapter DTRY-EC Rating Input : VC to VC / Hz,. Output: VDC, 7m Controller DTRY-EC Tungsten discharging needle for replacement (supplied by a set of needles) DTRY-EB Caution Dedicated for DTRY-E, DTRY-EB &. Dedicated tool for replacing the discharging needle Note: Bit alone is available. DTRY-EB Shape of the bit inserting section!

7 BOW TYPE Dimensions (mm) BOW TYPE Main Unit -head type DTRY-EB Power and signal cable (ccessory) Input power: + VDC Connector pin location and lead wire colors: # # # [White] & # [Black]: Contact point output # [Red] : Input power + VDC # [Green] : Groundpower # Ground terminal (Knurled nut ) Power and signal cablevctf-. mm wires JIS-C. Power and signal connector molex 7-R # Viewed from - Pin location of molex 7-R (female) Throttle valve With quick fitting Main Circuit Ground terminal (Green): V (Red): + VDC (Black): RM (White): RM Power VDC VDC OD VDC m MX INSIDE CIRCUIT OUTSIDE CIRCUIT Circuit Notes : ON/OFF of the power to the Ionizer should be done at the input side (+ VDC side). : Ground for power and ground terminal are connected inside. : For output of abnormality output contact point, see -. (Mounting hole) For power and signal connection 9. Connector (male) molex 9- NO/NC selector switch Discharging needle. NC NO RM 9 Power indicator ED (Green) bnormality indicator ED (Red) -head type DTRY-EB Power and signal cable (ccessory) Input power: + VDC Connector pin location and lead wire colors: # # # [White] & # [Black]: Contact point output # [Red] : Input power + VDC # [Green] : Groundpower # # Viewed from - Pin location of molex 7-R (female) Throttle valve With quick fitting Main Circuit INSIDE CIRCUIT Ground terminal (Green): V (Red): + VDC (Black): RM (White): RM OUTSIDE CIRCUIT Power VDC VDC OD VDC m MX Circuit Notes : ON/OFF of the power to the Ionizer should be done at the input side (+ VDC side). : Ground for power and ground terminal are connected inside. : For output of abnormality output contact point, see Ground terminal (Knurled nut ) -. (Mounting hole) Power and signal cablevctf-. mm wires JIS-C. Power and signal connector (molex 7-R) For power and signal connection.. Connector (male) (molex 9-) 9 NO/NC selector switch Discharging needle 7. NC NO RM 9! Power indicator ED (Green) bnormality indicator ED (Red)

8 BOW TYPE Nozzles Standard nozzle DTRY-NZRNS (M).7 Note. Stainless steel pipe nozzle DTRY-NZRS (M) Width across flats Width across flats BOW TYPE 7 () Note: The standard nozzle DTRY-NZRNS has a groove in the hexagonal section, to be distinguished from DTRY-NZRS (earlier model). 7 (7.) 7. (.) () Shower nozzle ( type) DTRY-NZRSW Shower nozzle (9 type) DTRY-NZRSW (M) (M) 7 7 () (.) 7- () 7- Flat nozzle DTRY-NZRFT (M) Width across flats Width across flats (nut) - 7 (.) 7 (.) (9) (.) (9.) Straight bar nozzle DTRY-NZRB Bracket for straight bar nozzle DTRY-EQ Width across flats Width across flats (nut) (M) Pitch N-. (.) () 7 () B C N DTRY-NZRB DTRY-NZRB DTRY-NZRB DTRY-NZRB DTRY-NZRB Supports the tip of straight bar nozzle M., ength Setscrew 7., Depth 7 M.7, ength Hexagon socket bolt ( pcs. supplied) Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn on.!

9 BOW TYPE Nozzles Spiral bar nozzle DTRY-NZRSP (M) Width across flats Width across flats (nut) () (.) -. () (9.7) U-shaped bar nozzle DTRY-NZRU -shaped bar nozzle DTRY-NZR () 7. Pitch Pitch -. Width across flats (M) 7 Section - viewed from C Width across flats (nut) (9) 7 R N-. 7. Width across flats (nut) 7. (.) () B C R 7 7 (.) (M) Width across flats Pitch -. DTRY-NZR DTRY-NZR N Section - viewed from B Free-mounting -shaped bar nozzle DTRY-NZRFMT N-. (7.7) (.7) Pitch 7 R Width across flats (nut) Width across flats Width across flats (nut) Width across flats 7 (.) (M) DTRY-NZRFMT DTRY-NZRFMT N Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn on.!

10 BOW TYPE Nozzles Bender nozzle DTRY-NZRND (M) BOW TYPE 7 () DTRY-NZRND DTRY-NZRND DTRY-NZRND DTRY-NZRND DTRY-NZRND Optional nozzle units for bender nozzles. (use the unit at the tip of a flexible tube for changing a nozzle) Bender shower nozzle unit ( type) DTRY-DN-SW Bender shower nozzle unit (9 type) DTRY-DN-SW Bender flat nozzle unit DTRY-DN-FT (9.).. ock nut - Bender bar nozzle unit DTRY-DN-B (.) (B) Pitch Width across flats Width across flats (nut) 7. N-. DTRY-DN-B DTRY-DN-B B N Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn on.!

11 COMPCT BOW TYPE Dimensions (mm) COMPCT BOW TYPE Main Unit -head type DTRY-E Throttle valve with quick-fitting.. Power and signal cable (ccessory) Input power: + VDC Connector pin location and lead wire colors: # # # [White] & # [Black]: Contact point output # [Red] : Input power + VDC # [Green] : Groundpower # # Main Circuit Ground terminal (Green): V (Red): + VDC (Black): RM (White): RM Power VDC Viewed from - Pin location of molex 7-R (female) INSIDE CIRCUIT OUTSIDE CIRCUIT Circuit Notes : ON/OFF of the power to the Ionizer should be done at the input side (+ VDC side). : Ground for power and ground terminal are connected inside. : For output of abnormality output contact point, see (MX.7.) Discharging needle (MIN..) NO/NC selector switch (.) VDC OD VDC m MX NC NO RM. 7. For power and signal connection () () Connector (male) molex 9- Power and signal cable : VCTF-. mm wires JIS-C. Power and signal connector (molex 7-R) Power indicator ED (Green) 77 bnormality indicator ED (Red) 7 -. Mounting hole M., Depth 7 (Ground terminal) Dual use as a tapped hole for mounting the main unit 7 M., Depth 7 Tapped hole for mounting the main unit Bracket (accessory) (Ground) note. COMPCT BOW TYPE Nozzles Standard nozzle DTRY-NZNS Note: Use a mounting hole on the bracket for grounding. (M) Note.7. 9 (7.). Note: The standard nozzle DTRY-NZNS has a groove in the hexagonal section, to be distinguished from DTRY-NZS (earlier model). Shower nozzle ( type) DTRY-NZSW Shower nozzle (9 type) DTRY-NZSW (M) (M). (9.) 7-. (.) 7-!7

12 COMPCT BOW TYPE Nozzles Flat nozzle (M) Width across flats (.) DTRY-NZFT Width across flats (nut) () (9.). 77 (.) - BOW TYPE Stainless steel pipe nozzle DTRY-NZS Width across flats Width across flats (M) (.).. () () Straight bar nozzle DTRY-NZB Width across flats Width across flats (nut) Pitch 7. (M) N-. (.) (B). C () DTRY-NZB DTRY-NZB DTRY-NZB DTRY-NZB DTRY-NZB B C N Spiral bar nozzle DTRY-NZSP (M) Width across flats Width across flats (nut) () (.) (9.7). (.). Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn on.!

13 COMPCT BOW TYPE Nozzles U-shaped bar nozzle DTRY-NZU -shaped bar nozzle DTRY-NZ -. (9.). Width across flats Pitch Pitch (M) (.) -. Width across flats (nut) R () () 7 R Width across flats (nut) Width across flats (.) (M) Free-mounting -shaped bar nozzle DTRY-NZFMT N-. (7.7) (.7) Pitch 7 R Width across flats (nut) Width across flats Width across flats (nut) Width across flats. (.) (M) DTRY-NZFMT DTRY-NZFMT N Bender nozzle DTRY-NZND (). () DTRY-NZND DTRY-NZND DTRY-NZND DTRY-NZND DTRY-NZND..... Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn on.!9

14 COMPCT BOW TYPE Optional nozzle units for bender nozzle (use the unit at the tip of a flexible tube for changing a nozzle) Bender shower nozzle unit ( type) DTRY-DN-SW Bender shower nozzle unit (9 type) DTRY-DN-SW9 BOW TYPE 7-7- Bender flat nozzle unit DTRY-DN-FT (9.).. ock nut - Bender bar nozzle unit DTRY-DN-B (.) (B) Pitch Width across flats Width across flats (nut) 7. N-. DTRY-DN-B DTRY-DN-B B N Remark: oosen the nut to adjust the direction of the Ionized air flow outlet. Note: Do not contact the nozzle with a grounded conductive object. The abnormality indicator ED may turn

15 Dimensions of Common Options for BOW TYPE and COMPCT BOW TYPE (mm) TUBES Conductive urethane tube DTRY-DN-U Conductive urethane tube Conductive urethane tube holder DTRY-NZR -. (7) M., two mm length screws ( pieces included in the main unit) Teflon tube DTRY-DN-F Teflon tube 7 Note: The DTRY-DN-F cannot be used for the earlier standard nozzles DTRY- NZRS and DTRY-NZS. Silicone tube DTRY-DN-S Silicone tube 7 Note: The DTRY-DN-S cannot be used for the earlier standard nozzles DTRY- NZRS and DTRY-NZS. (.) 9 (.) () () Viewed from Tube-securing screw (.) Note: The tube holder is the dedicated model for the conductive urethane tube DTRY-DN-U. It cannot be used with the Teflon tube DTRY-DN-F and the silicone tube

16 CONTROER DTRY-EC PF (In-line filter) ( For Blow Type and Compact Blow Type ) -. 9 () () External signal Pneumatic Circuit Diagram POWER ON OUT BOW TYPE (IN port) (99) 9 () () OV V q w r e q w GND r e w q GND rpowerr e e w q Electric Circuit Diagram w q IONIZER 7 (OUT port) Connector for external signal Note (molex 9-P) Connector for power supply Note (molex 9-P) Connector for Ionizer Note (molex MR) Notes:. The Controller is for the Blow Type Ionizer.. Provide VDC power with m or larger. For an C adapter, use the DTRY-EC.. The cable used to connect the controller and the Ionizer is included in the product.. For a power supply cable, use the power and signal cable in the Ionizer accessories.. Separately purchase a cable for external signals.. Ground the controller power supply and the Ionizer

17 Graphs of Static charge Removing Characteristics (Blow Type) The following graphs show static charge removing characteristics obtained when using the blow type Ionizer, DTRY-EB (-head type) with typical nozzles. Using the proper item to the proper place enables static charge removal with superior ion balance. Notes : The static charge removing characteristics are measured by in-house test standard using the charged plate monitor of pf, mm. Notse : The static charge removal time means decaying time from ± V to ± V. Photo shows a full-size For the graph of static charge removing characteristics obtained when using the standard nozzle DTRY-NZRNS, see page! Bender Nozzle ength and Static Charge Removing Characteristics Nozzle: DTRY-NZRND Conductive Urethane Tube ength and Static Charge Removing Characteristics When mounting the conductive urethane tube DTRY-DN-U to the nozzle DTRY-NZRNS Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Teflon Tube ength and Static Charge Removing Characteristics When mounting the Teflon tube DTRY-DN-F to the nozzle DTRY-NZRNS Silicone Tube ength and Static Charge Removing Characteristics When mounting the silicone tube DTRY-DN-S to the nozzle DTRY-NZRNS Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: MPa psi.

18 Graphs of Static charge Removing Characteristics Static Charge Removing Characteristics obtained when the Nozzle with Stainless Steel Pipe is used Static Charge Removing Characteristics obtained when Shower Nozzle ( type) is used Nozzle : DTRY-NZRS Nozzle : DTRY-NZRSW Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm BOW TYPE... Static Charge Removing Characteristics obtained when Shower Nozzle (9 type) is used..... Static Charge Removing Characteristics obtained when the Flat Nozzle is used Nozzle : DTRY-NZRSW Nozzle : DTRY-NZRFT Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm..... Static Charge Removing Characteristics obtained when the Spiral Bar Nozzle is used Nozzle : DTRY-NZRSP..... Static Charge Removing Characteristics obtained when the Straight Bar Nozzle ( mm) is used Nozzle : DTRY-NZRB Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm..... Static Charge Removimg Characteristics obtained when the Straight Bar Nozzle ( mm) is used..... Static Charge Removing Characteristics obtained when the Straight Bar Nozzle ( mm) is used Nozzle : DTRY-NZRB Nozzle : DTRY-NZRB Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm..... Static Charge Removing Characteristics obtained when the Straight Bar Nozzle ( mm) is used..... Static Charge Removing Characteristics obtained when the Straight Bar Nozzle ( mm) is used Nozzle : DTRY-NZRB Nozzle : DTRY-NZRB Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm MPa

19 Graphs of Static charge Removing Characteristics Static Charge Removing Characteristics obtained when the -shaped Bar Nozzle ( mm) is used Static Charge Removing Characteristics obtained when the -shaped Bar Nozzle ( mm) is used Nozzle : DTRY-NZR Nozzle : DTRY-NZR Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Static Charge Removing Characteristics obtained when the Free-mounting -shaped bar nozzle ( mm) is used Nozzle : DTRY-NZRFMT Static Charge Removing Characteristics obtained when the Free-mounting -shaped bar nozzle ( mm) is used Nozzle : DTRY-NZRFMT Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm Measured distance: mm..... Static Charge Removing Characteristics obtained when the U-shaped Bar Nozzle is used Nozzle : DTRY-NZRU Measured distance: mm..... Bender Nozzle ength and Static Charge Removing Characteristics (Shower Nozzle Type) When mounting the nozzle unit DTRY-DN-SW to the nozzle DTRY-NZRND..... Bender Nozzle ength and Static Charge Removing Characteristics (Shower Nozzle 9Type) When mounting the nozzle unit DTRY-DN-SW9 to the nozzle DTRY-NZRND Bender Nozzle ength and Static Charge Removing Characteristics (Flat Nozzle) When mounting the nozzle unit DTRY-DN-FT to the nozzle DTRY-NZRND... Bender Nozzle ength and Static Charge Removing Characteristics (Straight Bar Nozzle mm) When mounting the nozzle unit DTRY-DN-B to the nozzle DTRY-NZRND Bender Nozzle ength and Static Charge Removing Characteristics (Straight Bar Nozzle mm) When mounting the nozzle unit DTRY-DN-B to the nozzle MPa psi. Note: The static charge removing characteristics are measured by in-house test standard.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Series IZS31. RoHS compliant

Series IZS31. RoHS compliant Ionizer 3 types of the sensors are available. Autobalance sensor [High-precision type] Adjusts ion balance near the workpiece to reduce any interference! New Autobalance sensor [Body-mounting type] Rapid

More information

Injects ionized air over an angle of 60 or 90. Straight Bar Nozzle

Injects ionized air over an angle of 60 or 90. Straight Bar Nozzle Ionizer (Air Push Type) KS Wide Range of Nozzles for Optimal Ionization From pin-point to wide-area ionization, the optimal ionization for the application is now possible. High-frequency AC method with

More information

Ionizer (Nozzle type) Series IZN10

Ionizer (Nozzle type) Series IZN10 262 Series IZN0 / Nozzle type (Nozzle type) Series IZN0 RoHS Slim and compact: 6mm thickness. Nozzle selectable: Energy saving, large flow types and female threads for piping. ±0V ion balance: High frequency

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders The Pen Cylinder s compactness and easy handling make production lines in a broad range of industries. new release with even lighter weight and more PEN CYLINDERS Product series extended even more! The

More information

Static Electricity Removing Unit Ionizer Blow Type

Static Electricity Removing Unit Ionizer Blow Type Low particle generation type Catalog No.BK-R Static Electricity Removing Unit Ionizer Blow Type Series KOGANEI Brand All products are RoHS compliant. A wealth of variations Simple maintenance Standard

More information

ION JET NOZZLE NIH-55

ION JET NOZZLE NIH-55 ION JET NOZZLE NIH-55 INSTRUCTION MANUAL - Read this instruction manual and make sure you thoroughly understand its contents before attempting to operate, inspect or service this product. - The users and

More information

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORES PRODUCTS MNIFOLD REGULTORS MNIFOLD REGULTORS CONTENTS Features, Flow Rate Characteristics 115 Specifications, Port Size 116 Inner Construction,

More information

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method STATIC REMOVER UTRA-COMPACT IONIZER High-frequency AC Method ER-VSERIES Conforming to EMC Directive A new style of charge removal New ultra-compact, high-performance ionizer! Phone:.9.1 - Fax:.73.773 -

More information

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and

More information

High-frequency AC Method. panasonic-electric-works.net/sunx

High-frequency AC Method. panasonic-electric-works.net/sunx 1091 PHOTO PHOTO Thin Type Ionizer High-frequency AC Method General terms and conditions... F-17 Related Information Glossary of terms... P.1401 guide... P.1075~ General precautions... P.1405 Conforming

More information

New ultra-compact, high-performance ionizer!

New ultra-compact, high-performance ionizer! STATIC REMOVER UTRA-COMPACT IONIZER High-frequency AC Method ER-VSERIES Conforming to EMC Directive A new style of charge removal New ultra-compact, high-performance ionizer! AUDIN -, avenue de la malle

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations

More information

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves. ME12, ME25, ME60 Specifications Micro ejectors Media Operating pressure range MPa [psi.] Operating temperature range C [ F] Nozzle diameter Note mm [in.] kpa [in.hg] flow rate Note R/min [ft. 3 /min.]

More information

High-frequency AC Method. panasonic-electric-works.net/sunx. A new style of charge removal New ultra-compact, high-performance ionizer!

High-frequency AC Method. panasonic-electric-works.net/sunx. A new style of charge removal New ultra-compact, high-performance ionizer! 199 PHOTOEECTRIC PHOTOEECTRIC Ultra-compact SERIES Related Information High-frequency AC Method General terms and conditions... F-17 Glossary of terms... P.11 guide... P.175~ General precautions... P.15

More information

Design & Selection. Installation & Adjustment

Design & Selection. Installation & Adjustment U SM Series WRNING This product must not be used submerged in water, oil or powder, or where coolant, coolant fluid or swarf, etc., may come in contact. lways incorporate an interlock in the control circuit

More information

16mm. Ionizer Nozzle type. IZN10 Series. Offset voltage ±10 v Slim design: Thickness dimension 16 mm RoHS compliant

16mm. Ionizer Nozzle type. IZN10 Series. Offset voltage ±10 v Slim design: Thickness dimension 16 mm RoHS compliant Ionizer Nozzle type IZN10 Series Dust removal and static neutralization by air blow Eliminates dust clinging to lamp cover. RoHS Spot type static neutralization Prevents electrostatic breakdown of electric

More information

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORESIN PRODUCTS ELECTRO-PNEUMTIC TRNSDUCING REGULTORS CONTENTS ETR Series Features, Operation Principle 237 pplication Examples 238 Handling

More information

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME: Doc. No. IZ -OML0002-B OPERATION MANUAL PRODUCT NAME: MODEL: Ionizer IZN10 Series Read this operation manual carefully to understand before installation and operation. Pay extra attention on the clause

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Intermittent control timer

Intermittent control timer Contact our sales office regarding a delivery date or a price since this is a special model. P.G.Information (Specialized Product) SP095X-002E P: NU Intermittent control timer IZE110-X238 SMC CORPORATION

More information

Static Electricity Removal Unit Ionizer Ion Polarity Control Type

Static Electricity Removal Unit Ionizer Ion Polarity Control Type Catalog No.BK-R6 Static Electricity Removal Unit Ionizer Ion Polarity Control Type DTY-BX Series Compact body Body size 5 5 mm [.98.78 in] High voltage wiring not required, with built-in potential sensor

More information

SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm

SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm SOLENOID VALVES HEB series (2, 3-port pilot type solenoid valves) SOLENOID VALVES EA, EB SERIES 53mm 10mm 120 HEB SERIES SPECIFICATIONS Specifications Basic Models and Functions Item Basic model Number

More information

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves) Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves) 80mm 12mm 18mm Space Saving Thin and compact size Valve width: 12mm [0.472in.] Valve length: 80mm [3.150in.] Flow Large flow rate with

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems T-6-way valve NPT threads Standard control valves 6-way valve for change-over systems IMI T / Control valves / T-6-way valve NPT threads T-6-way valve NPT threads The 6-way valve solution enables various

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure sensor for liquid and gaseous media QBE620-P... 1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal

More information

Front Fork Disassembling and Assembling RM-Z250L6. KAYABA Pneumatic Spring Front Fork PSF2

Front Fork Disassembling and Assembling RM-Z250L6. KAYABA Pneumatic Spring Front Fork PSF2 Front Fork Disassembling and Assembling RM-Z250L6 KAYABA Pneumatic Spring Front Fork PSF2 RM-Z250L6 Front Fork Disassembling 1. Release air Release the air pressure by pressing the air valve with a screwdriver.

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

100 to 400 MPa Series

100 to 400 MPa Series 100 to 400 Series 100 Pumps 202 Accessories 203 200 Single-Acting Cylinders 204 Double-Acting Cylinders 205 Manual Pumps 206 SMP-200 207 Electric Pumps 208 Special Pumps 209 Valves 210 to 212 Pressure

More information

SOLENOID VALVES, SERIES

SOLENOID VALVES, SERIES VALVES GENERAL CATALOG SOLENOID VALVES, SERIES INDEX Features 103 Product Range 104 Handling Instructions and Precautions 105 EA Series Specifications 109 Order Codes 113 Dimensions 116 EB Series Specifications

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Pascal N2 Gas Balancer

Pascal N2 Gas Balancer Pascal N2 Gas Balancer modeldng BLNCER for SPINDLE HED CE marking Pressure Equipment Directive (97/23/EC) Japan Patent NO.4010525 & 3942365 US Patent NO.6,883,789 Germany Patent NO.60213368.8 www.pascaleng.co.jp

More information

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators ELECTRO-PNEUMTIC TRNSDUCING REGULTORS ETR Series Electro-Pneumatic Transducing Regulators fusion of air and electronics Flexibly control pressure. sequencer (PC) allows remote control operation. Feedback

More information

Series ADR. Double Rod Cylinder W1H ADR M Bore Size : ф10, ф16, ф20, ф25. How to Order A ACP UACP AM2 AM AL ALX ARD AQ2 AGX GX ADM ADR

Series ADR. Double Rod Cylinder W1H ADR M Bore Size : ф10, ф16, ф20, ф25. How to Order A ACP UACP AM2 AM AL ALX ARD AQ2 AGX GX ADM ADR Double Rod Cylinder Bore Size : ф10, ф16, ф, ф25 HIGH ATERA OAD CAPABIITY ADJUSTABE STROKE IS AVAIABE A THIN AND COMPACT DOUBE ROD CYINDER BA BUSHING OPTION AUTO SWITCH READY NON-UBE SERVICE STAND. A 2

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

King Of Valve Co.,Ltd.

King Of Valve Co.,Ltd. Series variation Series Series Series variation SCP* SCP* U Variation Double acting lubrication type Double acting oil-free type, with switch Double acting Stroke adjustable type (Extended) Double acting

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

ACTUATORS GENERAL CATALOG

ACTUATORS GENERAL CATALOG CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS VANE TYPE SERIES CONTENTS RAN (Standard Type) Basic Model and Configuration 259 Specifications 26 Order Codes 264 Dimensions

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

TUBES CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBES

TUBES CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBES ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Nylon Tubes, 489 Soft Nylon Tubes, 490 Urethane Tubes, 491 Flat Tubes,, Handling Instructions and Precautions

More information

Hydraulic Deadweight Tester Model CPB5800

Hydraulic Deadweight Tester Model CPB5800 Calibration technology Hydraulic Deadweight Tester Model CPB5800 Applications Primary standard for ranges up to 20,000 psi hydraulic Pressure reference / calibration standard used in production and calibration

More information

NDJ Series New DAIPACK

NDJ Series New DAIPACK DJ Series ew DIPK omenclature DJ - - 0-4 6 7 Model o. DJ: ew DIPK Pump capacity 8: V 8 used ( 8 cm /rev) : V used (4.8 cm /rev) Pressure adjustment range 9: 0.8 to. MPa {8 to kgf/cm } : 0.8 to 7 MPa {8

More information

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Compact Slide. Series MXH ø6, ø10, ø16, ø20 Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations

More information

Solenoid Valves JC, JE Series

Solenoid Valves JC, JE Series Easy-to-use, simple construction valves! Suitable for various needs and offering high-performance control, while achieving still lower power consumption, quicker response, and a larger flow rate! Solenoid

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Bore size: JSC3: φ40/φ50/φ63/φ80/φ100. JSC4: φ125/φ140/φ160/φ180

Bore size: JSC3: φ40/φ50/φ63/φ80/φ100. JSC4: φ125/φ140/φ160/φ180 764 Min. stroke length with switch ( switch) Brake cylinder: Double acting, single rod/double acting, no-lubrication -N Series : JSC3: φ40/φ50/φ63/φ80/φ100 JSC4: φ125/φ140/φ160/φ180 JIS symbol Specifications

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Static Electricity Prevention Equipment

Static Electricity Prevention Equipment Static Electricity Prevention Equipment Antistatic Equipment Don t charge static electricity (Conductivity) Fittings Tubing Pad Speed Controller Electrostatic Removal Equipment Eliminates static electricity

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.

More information

Specifications. Standard Stroke Table. Bore size (mm) Number of axes 200, 300, 400, 500,

Specifications. Standard Stroke Table. Bore size (mm) Number of axes 200, 300, 400, 500, Series REH Specifications Bore size mm Fluid ction Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Piston speed ubrication Stroke length tolerance Piping

More information

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Version Poppet valve Control

More information

Linear slide cylinder Double acting single rod type. Bore size: 4.5, 6, 8. Descriptions Bore size mm

Linear slide cylinder Double acting single rod type. Bore size: 4.5, 6, 8. Descriptions Bore size mm Linear slide cylinder Double acting single rod type LCM Series Bore size:.5, 6, 8 JIS symbol Specifications Descriptions LCM Bore size mm.5 6 8 Actuation Double acting Working fluid Compressed air Max.

More information

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8 Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole

More information

Internet For latest information, PDF catalogs and operation manuals

Internet  For latest information, PDF catalogs and operation manuals DJ Series ew DIPK omenclature Features DJ - - 0-4 6 7 Low noise The tank contains the pump and motor inside and functions itself as noise insulation panels to trap noise internally. Low oil temperature

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

MAGNET TYPE RODLESS CYLINDERS SERIES CONTENTS

MAGNET TYPE RODLESS CYLINDERS SERIES CONTENTS CD drawing data catalog is available. CTUTORS GENERL CTLOG MGNET TYPE RODLESS CYLINDERS SERIES CONTENTS Features 59 MRC Series Specifications 6 Order Codes 6 Inner Construction, Major Parts and Materials

More information

Pressure Transmitters

Pressure Transmitters Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Nozzle Type Ionizer. 16 mm x 100 mm x 46 mm 33% reduction. IZN10E Series CAT.ES A

Nozzle Type Ionizer. 16 mm x 100 mm x 46 mm 33% reduction. IZN10E Series CAT.ES A Nozzle Type Ionizer Slim Lightweight Thickness Width Height 16 mm x 100 mm x 46 mm 33% reduction 120 g a 80 g Offset voltage: ±10 V (For energy saving static neutralization nozzle) 16 mm RoHS 46 mm 100

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

2/2 or 3/2-way Miniature Rocker Solenoid Valve

2/2 or 3/2-way Miniature Rocker Solenoid Valve 2/2 or 3/2-way Miniature Rocker Solenoid Valve Type 0127 can be combined with... For maximum chemical resistance requirements Compact design with mm width and Cv ratings up to 0.08 Proven reliability since

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Pressure Sensors. for liquid and gaseous media

Pressure Sensors. for liquid and gaseous media 1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature

More information

2 Port Solenoid Valve For Dust Collector

2 Port Solenoid Valve For Dust Collector The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

SUB-LINE FILTERS CONTENTS

SUB-LINE FILTERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORES PRODUCTS SUB-LE FILTERS CONTENTS SUB-LE FILTERS Features, Handling Instructions and Precautions 155 Line Filters Specifications,

More information

Modular valve block MVB 100/200

Modular valve block MVB 100/200 Modular valve block MVB 100/200 Nominal size DN 15 Nominal size 1/2 Nominal pressure PN 6 bar www.asv-stuebbe.com/produkte/armaturen Characteristics MVB 100 Ideal for realising dosing and distribution

More information

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6 2257 North Penn Road Hatfield, PA 19440 (215) 997-0590 (800) 538-0750 Fax: (215) 997-3450 Publication 5100935 June 2005 INSTRUCTIONS Owner's Manual Ionizing Air Nozzles Models AN-2 and AN-6 SIMCO Static

More information

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL BK-UV Ver.1. Air Valve SOLENOID VALVES SERIES INSTRUCTION MANUAL Ver.1. 1 Handling Instructions and Precautions Terminal connector Non-locking type To operate the manual override, press it all the way

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

SOLENOID VALVES, SERIES

SOLENOID VALVES, SERIES VALVES GENERAL CATALOG SOLENOID VALVES, SERIES INDEX Features 365 Basic Models and Configuration 366 Solenoid Valve Order Codes 367 Manifold Order Codes 368 112 Series Specifications 369 Operating Principles

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CD drawing data catalog is available. VLVES GENERL CTLOG SOLENOID VLVES SERIES INDEX Features 293 Basic Models and Configuration 29 1 Series Specifications 297 Cylinder Operating Speed and Flow Rate 299

More information

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install. New Snap Disk Fixed setting pressure switches Compatible Refrigerants R22, R134a, R401, R402, R404, R407C, R410 and their lubricating oils, CO2 and R290 Our new range of electromechanical pressure switches

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

Mobile recleanable HEPA filter units for a flow of m 3 / h

Mobile recleanable HEPA filter units for a flow of m 3 / h Mobile recleanable HEPA filter units for a flow of 3.000 m 3 / h Page 1/11 consisting of Mobile online recleanable HEPA filter block, Type M-RHF hightec 1 x 2 and Mobile air conveyor block, Page 2/11 RHF

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX Features 133 Basic s and Configuration 133 Specifications 13 Solenoid Valve Order s 137 Manifold Order s 138 Operating Principles and Symbols 139 Dimensions

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

OVAL TURBO STEAM METER

OVAL TURBO STEAM METER Steam Turbine Flowmeter for Saturated Steam OV TURBO STEM METER Mini: GSM Standard: GS, GSV GENER This Turbo Steam Meter is specifically designed and built for the measurements of saturated steam consumption

More information

SPEED CONTROLLERS WITH QUICK FITTINGS

SPEED CONTROLLERS WITH QUICK FITTINGS SPEED CONTROLLERS WITH QUICK FITTINGS Union Straight Type Fittings for controlling the speed of actuators, such as cylinders. Superior flow rate characteristics and fine tuning adjustments in the low flow

More information

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX resenting our CD drawing data catalog VLVES GENEL CTLOG SOLENOID VLVES SEIES INDEX Characteristics 8 roduct ange 140 Handling Instructions and recautions 141 0 Series Specifications 142 Solenoid Valve