EXPERIMENT PITOT TUBE

Size: px
Start display at page:

Download "EXPERIMENT PITOT TUBE"

Transcription

1 Read the following BEFORE getting started: EXPERIMENT PITOT TUBE Objectives, Pitot tube: a) Understand dynamic pressure, static pressure, and total pressure, and how they can be used to find air velocity. b) Realize the effect that relative humidity, altitude, temperature, and barometric pressure can have on air density and therefore calculated air velocity c) Realize that calculated air velocity is a nonlinear function of hv, Velocity pressure d) Realize the applications that a pitot tube may have in determining air velocity, and therefore, airflow (CFM), in HVAC. e) Determine maximum static pressure EXPERIMENT Air velocity/flowrate Measurements 1. Read the following about duct system static and velocity pressures BEFORE starting: 2. Start experiment with only 6 inch duct (ATTACHED TO FAN). Read the static and velocity pressures from the manometers. (Note: the inclined manometer is graduated in 0.1 inches of water pressure; it is inclined for easier reading. Thu U-tube manometer, for static pressure, is also graduated in 0.1 inches of water pressure, but more difficult to read). Record the static and velocity pressures for this first case. The total pressure (total energy in airflow) is the sum of these two pressures. 3. Now block off all air flow (with book) at end of 6 inch duct and record static pressure only. How does this compare with total pressure in step 2, since now, there is no velocity pressure. Record the pressure. 4. Now, reduce the duct to 4 inch using the 6 inch X 4 inch reducer and 18 inch length of 4 inch pipe. Record the static and velocity pressures. The sum of these is total pressure. How does total pressure for 4 inch duct compare to total pressure for 6 inch duct? Explain why it is a smaller value (see duct system figure below). 5. Now, add the 4 inch Tee and insert into 6 inch X 4 inch reducer. Reduce the outlet branches of the Tee to 3 inch using the 4 inch X 3 inch reducers and 2 short lengths of 3 1

2 inch pipe. Note the 4 inch supply to the Tee must be reduced to two 3 inch outlets. Why? Record the velocity pressure at each 3 inch branch (outlet). 6. Now calculate the air velocities for each step above using velocity pressures (or read directly from inclined manometer, feet/min.) 7. Finally, calculate flowrates for each step above using flowrate calculator or Q=vA. (Q ft 3 /min, v ft/min, A, ft 2 -cross sectional area of duct). 8. Tabulate and discuss each step of the above procedures. 2

3 Experiment 4(A): AIR VELOCITY CALCULATION USING PITOT TUBE 1.Objective Calculation of air velocity using Pitot tube. 2.Apparatus: Pitot tube, manometer, fan. 3.Theory: The apparatus works on the principle of Bernoulli s principle. 3

4 Bernoulli s Principle states that the total pressure is the sum of the static pressure and the dynamic pressure. To move air fans and blowers are usually used. They work by imparting motion and pressure to the air. When the force or pressure from the fan blades causes the air to move, the moving air acquires a force or pressure component in its direction or motion due to its weight and inertia. This force is called the velocity pressure. It is measured in inches of water column (w.c). In operating duct system a second pressure is always present. It is independent of air velocity. Know as Static pressure, it acts equally in all directions. Total pressure is the sum of static pressure and velocity pressure. 4

5 Manometers for pitot measurement are offered in a choice of 2 scale types. Some are made specifically for air velocity measurement and are calibrated for ft/min.to correct the air reading for other than standard air conditions, the actual air density must be known. It may be known if relative humidity, barometric pressure and temperature are known. 4.Procedure: 1. The manometer is first checked for water level and adjusted by adding more. When the water is at the reference point the manometer is allowed to settle down. 2. The blower is switched on and the Pitot tube is held at the exits of the tubes. 3. The air pressure causes the water to move in the manometer which is calibrated in inches of water. a. record the air velocity and dynamic pressure off the red-dyed-water scale b. Record the static pressure from the U-Tube c. Measure and the diameter of the outlets in a suitable table. 4. Remove sections of the tubes and repeat step 3 until only 1 section of pipe is left 5. Use the velocity recordings and pipe diameters to calculate flow rate. Dwyer Calculator: 1.Set relative humidity on the scale provided. On scale opposite know dry bulb temperature, read correction factor. 2.Set temperature under barometric pressure scale. Read density of air over correction factor established in #1. 3.On the other side of calculator, set air density reading just obtained on the scale provided. 4.Under Pitot tube reading (velocity pressure, inches of water) read air velocity, feet per minute. 5.Observations: Most manometer scales are calibrated in inches of water. Using readings from such an instrument, the air velocity may be calculated using the basic formula. Reading from the manometer = inches of water V hv d V = Velocity of air in feet per minute 5

6 To determine the dry air density: hv Velocity pressureininchesof water d density of air inpoundsper cubicfoot P d b d density of air in pounds per cubicfeet P b=barometric static pressure in inches of mercury T absolute temperature (degrees F +460) Velocity of air This manometer includes a scale for reading air velocity at room temperature. T 6. Discussion of Results: Draw a figure of the experimental setup and label (or make a legend of) the flow rates, air velocities and pressures at each place recorded. 6

Determining static vacuum pressure required to ventilate Opti Carousel racks at various flow rates. Eric Corell. Page 1

Determining static vacuum pressure required to ventilate Opti Carousel racks at various flow rates. Eric Corell. Page 1 Determining static vacuum pressure required to ventilate Opti Carousel racks at various flow rates Eric Corell Page 1 Objective Due to changes in filter design, cage configuration, and newly introduced

More information

KEES, INC. BALANCING MANUAL

KEES, INC. BALANCING MANUAL KEES, INC. Products for Sheet Metal HVAC, Food Service, & Architectural Construction Industries 400 S. INDUSTRIAL DRIVE ELKHART LAKE, WISCONSIN 53020 920 876-3391 FAX 920 876-3065 FORWARD: BALANCING MANUAL

More information

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station Accutrol, LLC Product Sheet VTS Series US Patents 6,991,177 & 7,543,759 Digital Airflow Measurement Station Innovative features of the AccuStation VTS Series! Digital Airflow Sensing Modular Design Intuitive

More information

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC TURNING AIR INTO SOLUTIONS. AIR KITS Model FC CATALOG 150 June 2017 AIR KITS Overview FC Wheel Construction Air kit wheels are designed for speeds up to 7,000 ft/min. at 70 F. The blades are die-formed

More information

Methods of Testing Heavy Duty Dampers for Rating

Methods of Testing Heavy Duty Dampers for Rating Methods of Testing Heavy Duty Dampers for Rating AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL INC. The International Authority on Air System Components AMCA Publications Authority AMCA International

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN PROUDLY MADE IN R38089 THE USA Classified by UL to UL 2043 for heat release rate and smoke optical density. ABV-4 ABV-5 ABV-6 Product Information The ABV Automatic Balancing Valves maintain a constant

More information

Measuring probe For ventilation and air-conditioning Model A2G-FM

Measuring probe For ventilation and air-conditioning Model A2G-FM Special For ventilation and air-conditioning Model A2G-FM WIKA data sheet SP 69.10 Applications Air flow measurement in circular ventilation pipes Air flow measurement in rectangular ventilation ducts

More information

SUMMARY. St-jean-sur-Richelieu, 2016, January 12th Client : J.A. Roby Project :PI model : Polaris; Sirius; Véga; Antares; Centauri; Rigel

SUMMARY. St-jean-sur-Richelieu, 2016, January 12th Client : J.A. Roby Project :PI model : Polaris; Sirius; Véga; Antares; Centauri; Rigel SUMMARY St-jean-sur-Richelieu, 2016, January 12th 1 Introduction... 4 1.1 General... 4 1.2 Test unit information... 4 1.3 Results... 4 1.4 Pretest information... 5 2 Summary of test results... 5 2.1 Emissions...

More information

Differential Pressure Switch

Differential Pressure Switch Overview and Identification The BAPI Differential is ideal for air filter monitoring, static pressure proving, airflow proving or auxiliary fan actuation.because of its UL 353 Limit Control Listing, the

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

Air Flow Measurement Technologies

Air Flow Measurement Technologies Page 1/7 Typical Air Flow Measurement Applications Air Flow Control True Flow Feedback Theory of Vortex Shedding Air Flow Measurement Pitot Air Flow Measurement Thermal Air Flow Measurement Advantages

More information

2 - Air flow measuring sensors FloXact -Stick

2 - Air flow measuring sensors FloXact -Stick FloXact Stick 2.1 - FloXact -Stick Application The FloXact Stick is used to measure air velocity / air volume in HVAC systems. The design allows for easy installation in existing air duct or terminals.

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application CAT.NO. 120-97 SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application TABLE OF CONTENTS Introduction......3 Selection Examples......4-5 Correction Factors......6 Rating Tables.........7-17

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

V-SENSOR LOW AIR VELOCITY SENSOR

V-SENSOR LOW AIR VELOCITY SENSOR home VSENSOR LOW AIR VELOCITY SENSOR Ultra low velocity pressure measurement Traceable Calibration Certificate Excellent repeatability Self compensating zero Climate chamber compensated Long term span

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal fans

More information

NEBB STANDARDS SECTION-6, PART 2 PROCEDURES

NEBB STANDARDS SECTION-6, PART 2 PROCEDURES NEBB STANDARDS SECTION-6, PART 2 PROCEDURES SECTION 6 BASIC TAB MEASUREMENTS 6.1 INTRODUCTION The purpose of this Section is to describe the procedures used in making basic TAB measurements. These recommended

More information

Air Moving Solutions. axifan adjustable blade vaneaxial fans

Air Moving Solutions. axifan adjustable blade vaneaxial fans Air Moving Solutions. axifan adjustable blade vaneaxial fans MODEL TCVX CATALOG AX300 December 2012 VaneaxialFans Model TCVX The heart of the TCVX AXIFAN lies in its wheel. The manually adjustable blades

More information

BAC, BAF, BAH Central Station Air Handlers

BAC, BAF, BAH Central Station Air Handlers PRODUCT DATA & INSTALLATION Bulletin B80-BA-PDI-5 Part # 1097717 PRODUCT SUPPORT web: b-rp.ca/bah email: ahu@b-rp.ca call: 1-844-893-3222 x527 scan: BAC, BAF, BAH Central Station Air Handlers Indoor and

More information

VT-SENSOR AIR VELOCITY AND TEMP

VT-SENSOR AIR VELOCITY AND TEMP home VTSENSOR AIR VELOCITY AND TEMP Ultra low velocity pressure measurement Traceable Calibration Certificate Excellent repeatability Self compensating zero Climate chamber compensated Long term span stability

More information

testo Smart Probes The SMART world of Testo HVAC

testo Smart Probes The SMART world of Testo HVAC testo Smart Probes The SMART world of Testo HVAC My world just got a whole lot EASIER The most exciting development in HVAC Instruments. EVER. The biggest family of SMART instruments. Servicing heating

More information

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS amca CERTIFIED RATInGS VOLU-probe Pitot Airflow Traverse Probes FLOW MEASUREMENT STATION PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Accurate airflow measurement for demanding applications

More information

1 Aeroelasticity Phenomenon (Tacoma Narrows Bridge Disaster) Figure 1 Tacoma Narrows Bridge Disaster

1 Aeroelasticity Phenomenon (Tacoma Narrows Bridge Disaster) Figure 1 Tacoma Narrows Bridge Disaster 1 Aeroelasticity Phenomenon (Tacoma Narrows Bridge Disaster) Background This project deals with the interaction of wind with the elastic characteristics of a structure, which enables the structure to take

More information

Once in a while flat oval duct can be converted to the even more efficient shape of round, if the equivalent round size fits the available space.

Once in a while flat oval duct can be converted to the even more efficient shape of round, if the equivalent round size fits the available space. Introduction Round is the most efficient duct shape for transporting air. Round duct has less surface area, weight and fewer joints than rectangular duct. It is much easier to seal and can easily be specified

More information

Air Velocity. Table of Contents. Air Velocity Kits pgs Transmitters pgs Air Velocity

Air Velocity. Table of Contents. Air Velocity Kits pgs Transmitters pgs Air Velocity Table of Contents Measurement........................197-199 Meters/Thermo-Anemometers/Pitot Tubes pgs 201-211 Flow Charts.............................200 Series 400 Meters........................201 Series

More information

PROHOOD AIR CAPTURE HOOD MODEL PH731

PROHOOD AIR CAPTURE HOOD MODEL PH731 PROHOOD AIR CAPTURE HOOD MODEL PH731 The PH731 ProHood Capture Hood is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and

More information

Solutions from SPTT-3

Solutions from SPTT-3 Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static

More information

Air Handling Unit Fan Selection Guide

Air Handling Unit Fan Selection Guide KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4

More information

KoldLok Integral Raised Floor Grommet

KoldLok Integral Raised Floor Grommet p r o d u c t c e r t i f i c a t i o n r e p o r t KoldLok Integral Raised Floor Grommet Model 1010 Updated May 1, 2002 Prepared for Upsite Technologies, Inc. 2904 Rodeo Park Drive East Santa Fe, New

More information

ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2

ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2 AN ENTIRELY NEW TYPE OF HANDHELD METER ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2 How Does It Work? See Video Demos at www.evergreentelemetry.com. Evergreen Telemetry s innovative instrument architecture

More information

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Bulletin 8510-4 May 2000 Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Description Index Series 8500 Centrifugal Swingout Fans The Series 8500 Centrifugal

More information

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products. AMS Thermal Dispersion Pressure Differential Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based

More information

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace 1 stage PSC CXX-1-D 1 stage ECM CXX-1-X 2 stage PSC CXX-2-D 2 stage ECM CXX-2-V Modulating CXX-M-V, CXX-M-S Modulating Compact CC15-M-V

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work? Exercise 4-1 Flowmeters EXERCISE OBJECTIVE Learn the basics of differential pressure flowmeters via the use of a Venturi tube and learn how to safely connect (and disconnect) a differential pressure flowmeter

More information

Technical Information

Technical Information N 10 October 2010 A fan is a volume revolving machine that aims to move a mass of air. Each fan is specified by an operation curve linking airflow, pressure and speed. These fans curves gives technical

More information

Differential pressure switch for monitoring air pressure in HVAC systems.

Differential pressure switch for monitoring air pressure in HVAC systems. Document No. CAN55E-P5 November 4, QBM8- Differential Pressure Switch Description Features Application Product Numbers Ordering Differential pressure switch for monitoring air pressure in HVAC systems.

More information

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565 VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565 The VelociCalc Model 9565 series are portable handheld Multi-Function Ventilation Test Instruments featuring a menu-driven user interface for easy

More information

ATTACHMENT NO. 9 MWI FIELD TRIP REPORT DURING INTIAL TESTING OF PUMPING EQUIPMENT DTD 24 APRIL 2006

ATTACHMENT NO. 9 MWI FIELD TRIP REPORT DURING INTIAL TESTING OF PUMPING EQUIPMENT DTD 24 APRIL 2006 ATTACHMENT NO. 9 MWI FIELD TRIP REPORT DURING INTIAL TESTING OF PUMPING EQUIPMENT DTD 24 APRIL 2006 1 MWI FIELD TRIP REPORT By Dennis Strecker April 24, 2006 Upon arrival at the test facility on April

More information

Rev. 0 - March Air System Diagnostics Kit Instructions.indd 1

Rev. 0 - March Air System Diagnostics Kit Instructions.indd 1 Air System Diagnostics Kit Instructions Rev. 0 - March 2016 Air System Diagnostics Kit Instructions.indd 1 Air System Diagnostics Kit Instructions.indd 2 Table of Contents Table of Contents...1 Introduction...2

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....

More information

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev. Installation Guide DigiTract 4 Two Stage Heat/Cool Comfort Control System Part #DT4MAN Rev. October 2013 Zoning Systems That s all we do. TABLE OF CONTENTS...Page INTRODUCTION...1 SYSTEM DESCRIPTION...1

More information

Experiment No.3: Flow through orifice meter. Background and Theory

Experiment No.3: Flow through orifice meter. Background and Theory Experiment No.3: Flow through orifice meter Background and Theory Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters (Head flow meters)

More information

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS Direct Drive & Belt Driven Model VJ / VJBD CATALOG 476 June 2015 Vaneaxial Fans Model VJ / VJBD Type "J" The heart

More information

Tested: written by :

Tested: written by : TEST REPORT TEST OF A NON CATALYTIC WOOD BURNING STOVE FOR EMISSIONS AND EFFICIENCY PER EPA METHODS 28 AND 5G-3, FEBRUARY 1988 Client: Hichanse Model name : HCS-01 Attention: Rafaël Sanchez TESTED BY:

More information

ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2

ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2 AN ENTIRELY NEW TYPE OF HANDHELD METER ONE METER FOR: AIR, WATER, HUMIDITY, POWER & CO2 HOW DOES IT WORK? SEE VIDEO DEMOS AT WWW.EVERGREENTELEMETRY.COM. Evergreen Telemetry s innovative instrument architecture

More information

Tested by: written by :

Tested by: written by : TEST REPORT TEST OF A NON CATALYTIC WOOD BURNING STOVE FOR EMISSIONS AND EFFICIENCY PER EPA METHODS 28 AND 5G-3, FEBRUARY 1988 Client: Hichanse Model name : HCS-02 Attention: Rafaël Sanchez TESTED BY:

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN BY B.MADHAN KUMAR

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN BY B.MADHAN KUMAR International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July-2013 485 FLYING HOVER BIKE, A SMALL AERIAL VEHICLE FOR COMMERCIAL OR. SURVEYING PURPOSES BY B.MADHAN KUMAR Department

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-3 Venturi Tubes EXERCISE OBJECTIVE In this exercise, you will study the relationship between the flow rate and the pressure drop produced by a venturi tube. You will describe the behavior of

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5 -02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias SUBMITTAL Project Palm Beach Gardens Fire Station Date February 5, 2018 Fausto Frias Prepared For TLC Attention- Steve Job Name Palm Beach Gardens Fire Station Mark for AHU-1 Date February 5, 2018 Unit

More information

FLUID FLOW. Introduction

FLUID FLOW. Introduction FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting

More information

CENTRIFUGAL PUMP: Parallel and Series Operation 11/11/02

CENTRIFUGAL PUMP: Parallel and Series Operation 11/11/02 CENTRIFUGAL PUMP: Parallel and Series Operation 11/11/02 1 CENTRIFUGAL PUMP Location Sub-basement SB-92. (Manual is available) Introduction This experiment illustrates the basic operation and characteristics

More information

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point: Exercise 3-2 Pressure Loss EXERCISE OBJECTIVE Familiarize yourself with the pressure loss phenomenon. DISCUSSION OUTLINE The Discussion of this exercise covers the following point: Pressure loss Major

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................

More information

A) AirBoss Series (PAN-AB)

A) AirBoss Series (PAN-AB) A A) AirBoss Series (PAN-AB) C B The AirBoss zone control takes command of heating and cooling equipment. Features include built-in LAT monitoring which provides additional staging controls and a built-in

More information

F-35 Class Hovercraft Propulsion. Amber Deja December 2, 2014 AEM 495

F-35 Class Hovercraft Propulsion. Amber Deja December 2, 2014 AEM 495 F-35 Class Hovercraft Propulsion Amber Deja December 2, 2014 AEM 495 Goal Determine whether the University of Alabama Hoverteam F-35 Class hovercraft propulsion system should use a non-ducted propeller,

More information

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2 FAN ENGINEERING Information and Recommendations for the Engineer Twin City Fan FE-1800 Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia Introduction Bringing a fan up to speed

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX100-A October 2008 AXIFAN VANEAXIAL FANS TYPE TCVA TCVA Vaneaxial Fans The heart of the TCVA AXIFAN fan lies in its wheel. Cast of high strength aluminum alloy, the one-piece

More information

BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA BULLETIN VAV 107 VAV FANS Variable Air Volume Vane Axial Fans CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA D/47 Vane Axial Fans Chicago s Design 47 Vane Axial fans are specified by architects,

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

AXIFAN VANEAXIAL FANS

AXIFAN VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXIFAN VANEAXIAL FANS MODEL TCVA CATALOG AX100 JUNE 2013 VANEAXIAL FANS Model TCVA The heart of the TCVA AXIFAN fan lies in its wheel.

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL Fiberglass Axial Flow Fans Series 28 Series 28B Series 29 Series 29B Series 34 Series Series V BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 46 Bulletin A-39-N

More information

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group VERANTIS Environmental Solutions Group FRP Fans: CMHB Series 6-8-10 Performance and Technical Information Bulletin 11-6 Rev May 2013 VERANTIS Environmental Solutions Group Verantis Environmental Solutions

More information

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM Digital Air Flow Meter INSTRUCTION MANUAL ENGLISH DAFM4 DAFM4 VOL CFM LW MODE HOLD START STOP EXIT LW-D-AREA MAX / MIN [HOLD TO EXIT AVG AVG MODE] ON / OFF (SET) 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com

More information

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone. Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination

More information

Experiment (4): Flow measurement

Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time demonstrate applications of the

More information

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual The IAQ50 Air Damper/Monitor Installation and Maintenance Manual RUSKIN MANUFACTURING 3900 Dr. Greaves Road Kansas City, Missouri 64030-1183 U.S.A. ! WARNING DO NOT TAMPER WITH (REMOVE, REPLACE, RELOCATE

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

Air- Blast Sprayer Calibration for Pecan Orchards

Air- Blast Sprayer Calibration for Pecan Orchards Air- Blast Sprayer Calibration for Pecan Orchards Air-blast Sprayer Calibration for Pecan Orchards Chemical pesticides are the most commonly used method for controlling arthropod and disease pests on pecan.

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

Users Manual. Airflow Meter

Users Manual. Airflow Meter 922 Airflow Meter Users Manual PN 2683880 November 2006 Rev.1, 12/07 2006-2007 Fluke Corporation, All rights reserved. Printed in Taiwan. Product specifications are subject to change without notice. All

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODELS CRVMWH-3 For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

Introducing NJK Precision Airflow Measuring Stations

Introducing NJK Precision Airflow Measuring Stations Introducing Precision Airflow Measuring Stations A new and unique airflow measuring station that accurately measures airflows at very low flow rates and can operate in physically restrictive applications

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

NJK Precision Product NJK-02 Sensor Installation Guide

NJK Precision Product NJK-02 Sensor Installation Guide Precision -02 Sensor 2017 Product Line Precision Product Table of Contents Precision Company Overview - Page 2-02 Installation Guidelines - Page 3-02 Recommended Installations - Page 5-02 Non-Recommended

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MiniCOREVentilator ENERGY RECOVERY CORE INSTALLATION INSTRUCTIONS MC500-1ERV JANUARY 10, 2018 SUPERSEDES: NONE INSTALLATION INSTRUCTIONS FOR MINICORE VENTILATOR (MCV) WITH FACTORY INSTALLED OPTIONS USED

More information

DIGITAL ANEMOMETER MODEL DCFM8906

DIGITAL ANEMOMETER MODEL DCFM8906 OPERATING INSTRUCTIONS DIGITAL ANEMOMETER MODEL DCFM8906 CFM AIR FLOW METER A. MEASURING AIR VELOCITY (SINGLE POINT) FEET PER MINUTE (FPM) 1. Press the ON/OFF button and turn meter on. Meter will show

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.

More information

PRODUCT ANNOUNCEMENT. There is a better way to measure air flow. The New Fluke 922 Airflow Meter

PRODUCT ANNOUNCEMENT. There is a better way to measure air flow. The New Fluke 922 Airflow Meter PRODUCT ANNOUNCEMENT There is a better way to measure air flow The New Fluke 922 Airflow Meter Fluke announces the new 922 Airflow Meter, making airflow measurements easy by combining three tools: differential

More information

Dimension and Selection Guide

Dimension and Selection Guide Dimension and Selection Guide GAS/OIL HEATING ONLY IDF-35 through IDF-125 Upright Model Dimensions LD RD LD or RD RA N END VIEW LEGEND BD = Bottom Discharge BD = Bottom Discharge = Top Discharge = Outside

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

Gold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1

Gold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1 Thermal Dispersion Airflow Measurement Model GF1 Technical Manual Gold Series Thermal Dispersion Airflow Measurement Technology Advantage Gold Series by Ebtron Installation, Operation and Maintenance Technical

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

Installation Instructions

Installation Instructions 08A0, 09A0, 08A00, 08A00 For Use With Horizontal EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY HORIZONTAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS

More information

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Pre-lab Questions: Please review chapters 19 and 20 of your textbook Introduction Magnetism and electricity are closely related. Moving charges make magnetic fields. Wires carrying electrical current in a part of space where there is a magnetic field experience a force.

More information

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114 SUMMARY 1 Introduction... 4 1.1 General... 4 1.2 Test unit information... 4 1.3 Results... 4 1.4 Pretest information... 4 2 Summary of test results... 5 2.1 table 1A: Data Summary Part A... 5 2.2 table

More information