1 Installation MP9800 Series Instructions Multi-Point Lock MP9800 with MELR Series Option Multi-Point (Electric Latch Lock Retraction), the global leader in door opening solutions 1 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

2 Table of Contents Warnings... 2 General Description... 3 Hardware Specifications... 3 Electronic Specifications... 3 Parts Breakdown Installation Instructions Concealed Door Position Switch Instructions (708F989) Wiring Diagrams Mechanical Operational Check Electrical Operational Check Warnings Changes or modifications to this unit could void the user s authority to operate the equipment. ALWAYS disconnect power before making any electrical or mechanical adjustments to the system. Observe precautions for handling electrostatic sensitive devices. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced TV technician for help This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme avec la norme NMB-003 du Canada. The term IC: before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appareillage numérique de la classe B répond à toutes les exigences de l interférence canadienne causant des règlements d équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l interférence nocive, et (2) ce dispositif doit accepter n importe quelle interférence reçue, y compris l interférence qui peut causer l opération peu désirée. Important: Any retrofit or other field modification to a fre rated opening can potentially impact the fire rating of the opening, and Corbin Russwin Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (authority having jurisdiction) to ensure compliance with all applicable codes and ratings Copyright 2016 Corbin Russwin Inc., an Group company. 2 of 20, the global leader in door opening solutions

3 2 General Description All Access 600 Multi Point Locks The Corbin Russwin multi-point lock combines all standard access control components into a single device. This integrated approach significantly reduces installation time and creates a streamlined aesthetic that blends flawlessly into any environment. The Access 600 features an open architecture platform that can easily be integrated into existing access control systems. Tools Required - (Same for all Series Products) Phillips screw driver UL and CUL listed for use on Fire Doors Multi point lock furnished for 1-3/4" doors Fail safe or fail secure available Drill with bits Door Position Switch (708F989) supplied for monitoring 24VDC solenoid-operated trim available Wire from EAC Panel to door must be shielded with a drain terminated at EAC Panel controller Access 600 MP9800 Series Multi Point Lock Cylinder override available for MP9800 with Auxiliary Control Slotted screw driver 3 Hardware Specifications 4 Electronic Specifications 12VDC System: Reader Draw = 150mA 12VDC Solenoid Draw= 500mA Total System Draw = 650mA 24VDC System: #8-32 tap & drill (for metal door applications) The M khz (proximity) version of the Open Architecture Wiegand Access Control platform requires a proximity card/fob/tag presentation to gain entry. The 125 khz reader operates on 12 VDC. The M MHz iclass (contactless) version of Open Architecture Wiegand Access Control Platform requires an iclass card/fob/tag presentation to gain entry. The MHz iclass reader operates on 12VDC or 24VDC. Access 600 M802 Reader Draw = 150mA (Reader is always 12VDC) 24VDC Solenoid Draw= 250mA Total System Draw = 400mA Access 600 M812 12VDC Solenoid Draw = 500mA Total System Draw = 625mA 24VDC Solenoid Draw = 250mA Total System Draw = 375mA 12VDC System (MELR): Reader Draw = 150mA 12VDC MELR Module Draw = 850mA Total System Draw = 1 Amp 24VDC System (MELR): Reader Draw = 150mA (Reader is always 12VDC) 24VDC MELR Module Draw= 700mA Total System Draw = 850mA 12VDC MELR Module Draw = 850mA Total System Draw = 975mA 24VDC MELR Module Draw = 700mA Total System Draw = 825mA Wire Gauge Charts Total One-Way Length of Wire Run (ft) Load 12VDC 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A , , Total One-Way Length of Wire Run (ft) Load 24VDC 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A , , , the global leader in door opening solutions 3 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

4 5 Parts Breakdown Access 600 Series M802 MP9800 Series Top Case Assembly Metal Door & MPAD Top Rod and Bolt Assembly M802 PCB and HID Module Assembly M802 Reader Assembly O/S Access 600 Gasket Mounting Plate I/S Access 600 Gasket I/S Access 600 Escutcheon Inside Trim Assembly Outside Trim Assembly Inner Chassis Assembly Inner Chassis Assembly, Fire Monitoring Inner Chassis, Fire Bottom Rod and Bolt Assembly Bottom Case Copyright 2016 Corbin Russwin Inc., an Group company. 4 of 20, the global leader in door opening solutions

5 5 Parts Breakdown - Continued Access 600 Series M812 MP9800 Series Top Case Assembly Metal Door & MPAD Top Rod and Bolt Assembly M812 Reader Assembly O/S Access 600 Gasket Mounting Plate I/S Access 600 Gasket I/S Access 600 Escutcheon Inside Trim Assembly Outside Trim Assembly Inner Chassis Assembly Inner Chassis Assembly, Fire Monitoring Inner Chassis, Fire Bottom Rod and Bolt Assembly Bottom Case, the global leader in door opening solutions 5 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

6 MP9800 Series Multi-Point Lock 5 Parts Breakdown - Continued Access 600 Series M802 MELR Add-on Top Case Assembly Metal Door & MPAD Top Rod and Bolt Assembly MELR Assembly Screw Pack I/S MELR Escutcheon Assembly M802 Reader Assembly O/S Access 600 Gasket Screw Pack M802 PCB and HID Module Assembly Outside Trim Assembly Inside Trim Assembly Inner Chassis Assembly Inner Chassis Assembly, Fire Monitoring Inner Chassis, Fire Bottom Rod and Bolt Assembly Bottom Case Copyright 2016 Corbin Russwin Inc., an Group company. 6 of 20, the global leader in door opening solutions

7 MP9800 Series Multi-Point Lock 5 Parts Breakdown - Continued Access 600 Series M812 MELR Add-on Top Case Assembly I/S MELR Escutcheon Assembly Metal Door & MPAD Top Rod and Bolt Assembly MELR Assembly Screw Pack M812 Reader Assembly O/S Access 600 Gasket Screw Pack M812 Controller Assembly Outside Trim Assembly Inside Trim Assembly Inner Chassis Assembly Inner Chassis Assembly, Fire Monitoring Inner Chassis, Fire Bottom Rod and Bolt Assembly Bottom Case, the global leader in door opening solutions 7 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

8 6 Installation Instructions A) Door Preparation Inside 1. Verify Hand and Bevel of Door -(Figure 1) Check hand of door. The multi-point lock may be handed. Door should be fitted and hung. Verify box label for size of the multi-point lock, function and hand. Change hand if necessary. Left Hand Reverse LHR Fig. 1- Handing Outside Access 600 Right Hand Reverse RHR 2. Door Preparation If door is not pre-drilled, prepare door according to the appropriate template. Refer to templates at (Figure 2). Metal door (Steel & MPAD): FM438 - Templates: T31242 Wood door (MPWD): FM436 - Templates: T31243 Fig. 2- M802/M812 Metal Door Prep Outside Inside Note: For MELR door prep see Step E, and use plastic template. B) Rod and Top Case Installation 1. Refer to instruction sheet FM438 for rod and inner case installation on metal doors. 2. Refer to instruction sheet FM436 for rod and inner case installation on wood doors. (Figure 3). Fig. 3- Top Case Installation Outside Copyright 2016 Corbin Russwin Inc., an Group company. 8 of 20, the global leader in door opening solutions

9 6 Installation Instructions - Continued C) Install Outside and Inside Trim Outside Trim 1. For exterior applications, use gasket (765F859) to seal escutcheon and outside door surface (Figure 4). 2. Feed wire through the through hole and attach the outside exit trim to the door. Fig. 4 Outside Exit trim Inside Trim 1. Position trim carefully onto the inside of the door. Be careful not to pinch wire harness. 2. Mount inside trim lever using (2) # 1/4"-20 x 3" Philips oval head machine screws. (Figure 5). Fig. 5 Inside Exit trim D) Install Outside Escutcheon 1. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door through the ribbon cable hole on the door. (Figure 6). Fig. 6, the global leader in door opening solutions 9 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

10 6 Installation Instructions - Continued E) Install Inside Mounting Plate On Multi Point Lock Without MELR 1. Securely tighten the outside escutcheon with (2) #8-32 x 2" Phillips lat head screws through the mounting plate. (Figure 7). Fig. 7 (2) #8-32 x 2" Phillips Flat Head Screws On Multi Point Lock With MELR F) Preparation of MELR Mounting Holes (If Required) Important: If the manufacturer has not pre-drilled the door, prepare the door per instructions below, using plastic template included with the device. Screw hole orientation is not affected by handing. (See Figures 8a-8d). If the door is pre-drilled by the manufacturer, continue to instructions on the following page. Mark Vertical Centerline Fig. 8a Centerline 1. Mark vertical centerline of slot and wire hole on door. (See Figure 8a). 2. Mount template onto plate as shown. For wood doors, ensure the template notch is touching the rod to provide lateral positioning. (See Figure 8c). Wire Hole 3. Check that template is square to door. (See Figure 8b). 4. Using template bushings as a guide, drill (4) 1/16" holes. (See Figure 8d). Fig. 8b- Template Template in Position 5. Remove template. 6. For metal door, increase 1/16" pilot holes to #29 (.136) and tap for #8-32. Detail of Notch in Template Aligned to Vertical Centerline Wire Hole Template Template Holes Location Detail of Template Notch Touching Rod and Resting on Plate (Wood Door Shown) Fig. 8d Fig. 8c Copyright 2016 Corbin Russwin Inc., an Group company. 10 of 20, the global leader in door opening solutions

11 6 Installation Instructions - Continued G) Installation of MELR Assembly Door Fig. 9a 1. Install the upper left mounting screw, #8-32 x 5/8" Fillister head for metal door and #8 x 5/8" self tapping wood screw for wood doors. (See Figure 9a). Mounting Bracket Note: Leave the screw loose enough to slide the MELR assembly on. 2. Snake the wire through the MELR assembly. Upper Left Mounting Screw 3. Slide the mounting bracket of the MELR assembly underneath the installed screw and secure in place. IMPORTANT: Ensure MELR retraction lever is resting on plate. (Fig. 11). 4. Completely tighten the upper left mounting screw. IMPORTANT: Be careful not to pinch or disconnect the wires located in that area. 5a. Install the remaining (3) #8-32 x 5/8" Fillister mounting screws on metal doors. (See Figure 9b.) 5b. Install the remaining (3) #8 x 5/8" self tapping wood screws on wood doors. (See Figure 9b.) 6. Install (2) 1/4"self-tapping screws on either diagonal, one above molex connector and one below. (Figure 10). Fig. 9b 7. Connect the 8-pin molex connectors. Fig. 10 Fig. 11- MELR Lever Resting on Plate #8-32 x 5/8" #8 x 5/8" Wood Screw 1/4" Self-Tapping Screw #8-32 x 5/8" Fillister Head Machine Screw (2) 1/4" Self-Tapping Screws, the global leader in door opening solutions 11 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

12 6 Installation Instructions - Continued H) Attach Trim Ground Wire 1. Connect pin 5 green/yellow ground wire ring terminal (from the inside trim) to top left screw. (Figure 12). Fig. 12 (Detail) Fig. 12 I) Connect Electrolynx Harness (for Access 600 x M802) J2 Note: If you are installing a Access 600 M812 please proceed to Step I. 1. Connect P3 (2-pin connector) from lock body or MELR assembly to J3 on interior PCB assembly. 2. Connect P4 (6-pin connector) from lock body assembly to J4 on interior PCB assembly. 3. Connect P5 (7-pin connector) from Reader board to J5 on interior PCB assembly. 4. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior PCB assembly. Note that connectors go on only one way. Do not offset connector and be sure they are completely seated. (Figure 13). 1-Violet Lock DC Neg PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) 3 - Pink J1 1- Black 3-White 5-Orange 7-Brown J2 To ElectroLynx Harness From Lock Body P4 to J4 From Reader Board P5 to J5 J1 From Lock Body or MELR Assembly P3 to J3 (Solenoid, neg) 2-Gray, Lock DC Pos NOT USED 4-Tan PWR GND 2-Red Wiegand DATA 1 4-Green RX (N/O) 6-Blue EGND 8-Yellow Fig. 13 (Solenoid, pos) NOT USED PWR 12VDC Wiegand DATA 0 RX (COM) LED Copyright 2016 Corbin Russwin Inc., an Group company. 12 of 20, the global leader in door opening solutions

13 6 Installation Instructions - Continued J) Position Inside Escutcheon and Wires (for Access 600 x M802) Please follow these steps prior to installing inside escutcheon assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx connectors (8 and 4-pin) to one side of the wire guide inside of the door prep. The reader connections and excess wire are arranged on the other. 2. Connect the ElectroLynx connectors (8 and 4-pin) and establish their position inside of the door prep on the proper side of the wire guide. (Figure 14). 3. Neatly route the remaining wires onto themselves and into the remaining space to prevent pinching wires when mounting the escutcheon. (Figure 15). Inside of Door Fig. 14 Fig. 15 K) Connect ElectroLynx Harness (for Access 600 x M812) From Reader Board P5 to J5 Notes: 1. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly. (Figure 16). 2. Connect ElectroLynx harness (4 and 8-pin) from door to interior PCB assembly. (Figure 16). a. Neatly fold the wires onto themselves and into the remaining space to prevent pinching wires when mounting escutcheon. J5 J1 To ElectroLynx Harness J2 b. Do not tuck extra lock body wires back inside the lock body cylinder hole. c. Connectors go on only one way. d. Do not offset connector and be sure they are completely seated. PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) Fig. 16 J2 J1 1-Violet Lock DC Neg 3 - Pink 1- Black 3-White 5-Orange 7-Brown (Solenoid, neg) NOT USED PWR NEG Wiegand DATA 1 RX (N/O) EGND 2-Gray, Lock DC Pos 4-Tan 2-Red 4-Green 6-Blue 8-Yellow (Solenoid, pos) NOT USED PWR POS Wiegand DATA 0 RX (COM) LED, the global leader in door opening solutions 13 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

14 6 Installation Instructions - Continued L) Attach Connectors-Exterior PCB Assembly- (for Access 600 x M812) 1. Connect P3 (2-pin connector) from lock body or MELR to J3 on module (Figure 17). 2. Connect P4 (6-pin connector) from lock body to J4 on module (Figure 17). Fig. 17 From Lock Body or MELR P3 to J3 J3 J3 J4 J4 From Lock Body P4 to J4 M) Position Inside Escutcheon and Wires (for Access 600 x M812) Please follow these steps prior to installing inside escutcheon assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx connectors (8 and 4-pin) to one side of the wire guide inside of the door prep. The reader connections and excess wire are arranged on the other. 2. Connect the ElectroLynx connectors (8 and 4-pin) and establish their position inside of the door prep on the proper side of the wire guide. 3. Neatly route the remaining wires onto themselves and into the remaining space to prevent pinching wires when mounting the escutcheon. Copyright 2016 Corbin Russwin Inc., an Group company. 14 of 20, the global leader in door opening solutions

15 6 Installation Instructions - Continued N) Position Inside Escutcheon & Wires (MELR) M802 or M Position escutcheon against door by hooking the top edge on the top of the MELR assembly. Verify that no wires are being pinched. 2. Mount inside escutcheon assembly to plate using (1) #8-32 x 5/8" Phillips lat head undercut machine screw. (Figure 18-20). Fig. 18- Machine Screw Detail 7 Concealed Door Position Switch Instructions Use Concealed Door Position Switch 708F989 with this product: Fig. 19- M802 MELR 1. Concealed Door Position Switch Model 708F989 is included with this product. System integrator shall determine use and installation location. 2. Drill a 1" Diameter Hole for both the Magnet and the Switch. Both holes shall be 1" Deep and for the Switch (if needed) drill a 1/4" hole for the wires. 3. Connect the common wire of the switch to the common input terminal of the EAC. 4. Connect the normally open wire of the switch to the normally open input terminal of the EAC. (Figure 21). 12VDC: Optional 24VDC Lock Available (Reader is always 12VDC) Fig. 20- M812 MELR Wiegand Access Control System Green (NC) Door Position Switch White McKinney Electric Hinge Fig. 21, the global leader in door opening solutions 15 of 20 Copyright 2016 Corbin Russwin Inc., an Group company.

16 8 Wiring Diagrams Product 8 PIN CONNECTOR 4 PIN CONNECTOR Corbin Russwin ACCESS 600 SERIES, M802 Exits 1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-Tan ACCESS CONTROL DEVICES: Access 600 x M802 Exits, ElectroLynx wire Color / Function assignments 12VDC Reader Power WIE- GAND WIE- GAND RX (NO) NEG POS DATA_1 DATA_0 REF. STEP 2A RX (COM) REF. STEP 2A EGND LED 12 OR 24 VDC (LOCK RELAY REF. DIA- GRAMS REF. DIA- GRAMS DPS (NC) DPS (COM) NEG POS N/A N/A PIN8 (Yellow LED) PIN 6 (Blue RX) PIN 4 (Green Data 0) PIN 2 (Red Reader POS) PIN 4 (not used) PIN 2 (Gray Lock POS) PIN 1 (Black Reader NEG) PIN 3 (White Data 1) PIN 5 (Orange RX) PIN 7 (Brown-EGND) PIN 1 (Violet Lock NEG) PIN 3 (not used) Reader LED Configuration The Access 600 Series reader can be configured for (3) modes of LED operation: Mode 1: Red LED ON when powered. Presenting a 125kHz proximity card will cause LED to FLICKER Green and return to Red state. Reference Diagram #1 as a function of power requirement (12VDC or 24VDC). Mode 2: Note: LED wire is unconnected. Green LED ON when powered. (No Flicker) after presenting valid 125kHz proximity card. Reference Diagram #2 as a function of power requirement (12VDC or 24VDC). Mode 3: Note: LED wire must be connected to circuit GROUND of the system s power supply. EAC Panel controls LED operation. Reference Diagram #3 as a function of power requirement (12VDC or 24VDC). Note: Control of LED is a function of the EAC Panel equipment (i.e. relay) to toggle between Green & Red. Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader performance will be impacted. Reference Diagram #3. Copyright 2016 Corbin Russwin Inc., an Group company. 16 of 20, the global leader in door opening solutions

17 8 Wiring Diagrams - Continued Typical Access 600 Application Diagram (12/24VDC Lock) DIAGRAM #1 MODE 1: LED WIRE NOT USED = RED LED "ON" WHEN POWERED Standard Application Shown - For Alternative Applications Contact WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated 12VDC System: Access 600 M802 Reader Draw = 150mA 12VDC Solenoid Draw= 500mA Total System Draw = 650mA Access 600 M812 12VDC Solenoid Draw = 500mA Total System Draw = 625mA 24VDC System: Reader Draw = 150mA (Reader is always 12VDC) 24VDC Solenoid Draw= 250mA Total System Draw = 400mA 24VDC Solenoid Draw = 250mA Total System Draw = 375mA 12VDC System (MELR): Reader Draw = 150mA 12VDC MELR Module Draw = 850mA Total System Draw = 1 Amp 12VDC MELR Module Draw = 850mA Total System Draw = 975mA 24VDC System (MELR): Reader Draw = 150mA (Reader is always 12VDC) 24VDC MELR Module Draw= 700mA 24VDC MELR Module Draw = 700mA Total System Draw = 850mA Total System Draw = 825mA Green (NC) Black (Hot) White (Neutral) Green (Gnd) White Door Position Switch 120 VAC Input H N G 12/24VDC - + Lockbody Power Supply (By Others) 12 Conductor ElectroLynx Harness From McKinney QC12 Electric Hinge From McKinney READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 0 - Green, 4 RX (NO/NC) - Orange, 5 RX (COM) - Blue, 6 *EGND- Brown, 7 LED - Yellow, 8 LOCK NEG - Violet, 9 LOCK POS - Gray, 10 Not Used (-) 12VDC (+) DATA 1 DATA 0 RX RX Use (NC) for Fail Safe Operation Electronic Access Control Panel (By Others) Lock Relay M802 Access 600 Series DPS DPS (NO) Fail Secure Operation, the global leader in door opening solutions 17 of 20 *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. Copyright 2016 Corbin Russwin Inc., an Group company.

18 8 Wiring Diagrams - Continued Typical Access 600 Application Diagram (12/24VDC Lock) DIAGRAM #2 MODE 2: LED WIRE TIED TO GROUND = GREEN LED "ON" WHEN POWERED Standard Application Shown - For Alternative Applications Contact WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated Access 600 M802 Access 600 M812 12VDC System: Reader Draw = 150mA 12VDC Solenoid Draw= 500mA Total System Draw = 650mA 12VDC Solenoid Draw = 500mA Total System Draw = 625mA 24VDC System: Reader Draw = 150mA (Reader is always 12VDC) 24VDC Solenoid Draw= 250mA Total System Draw = 400mA 24VDC Solenoid Draw = 250mA Total System Draw = 375mA 12VDC System (MELR): Reader Draw = 150mA 12VDC MELR Module Draw = 850mA Total System Draw = 1 Amp 12VDC MELR Module Draw = 850mA Total System Draw = 975mA 24VDC System (MELR): Reader Draw = 150mA (Reader is always 12VDC) 24VDC MELR Module Draw= 700mA Total System Draw = 850mA 24VDC MELR Module Draw = 700mA Total System Draw = 825mA Green (NC) White 3287 Door Position Switch 120 VAC Input Black (Hot) H N G 12/24VDC - + White (Neutral) Green (Gnd) Lockbody Power Supply (By Others) 12 Conductor ElectroLynx Harness From McKinney QC12 Electric Hinge From McKinney READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 0 - Green, 4 RX (NO/NC) - Orange, 5 RX (COM) - Blue, 6 *EGND - Brown, 7 LED - Yellow, 8 (-) 12VDC (+) DATA 1 DATA 0 RX RX Use (NC) for Fail Safe Operation Electronic Access Control Panel (By Others) LOCK NEG - Violet, 9 LOCK POS - Gray, 10 Lock Relay M802 Access 600 Series DPS DPS (NO) Fail Secure Operation Copyright 2016 Corbin Russwin Inc., an Group company. 18 of 20 *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure., the global leader in door opening solutions

19 8 Wiring Diagrams - Continued Typical Access 600 Application Diagram (12/24VDC Lock) DIAGRAM #3 MODE 3: LED WIRE TO EAC PANEL = EAC PANEL CONFIGURABLE Standard Application Shown - For Alternative Applications Contact WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated 12VDC System: Access 600 M802 Reader Draw = 150mA 12VDC Solenoid Draw= 500mA Total System Draw = 650mA 24VDC System: Reader Draw = 150mA (Reader is always 12VDC) 24VDC Solenoid Draw= 250mA Total System Draw = 400mA 12VDC System (MELR): Reader Draw = 150mA 12VDC MELR Module Draw = 850mA Total System Draw = 1 Amp 24VDC System (MELR): Reader Draw = 150mA (Reader is always 12VDC) 24VDC MELR Module Draw= 700mA Total System Draw = 850mA Access 600 M812 12VDC Solenoid Draw = 500mA Total System Draw = 625mA 24VDC Solenoid Draw = 250mA Total System Draw = 375mA 12VDC MELR Module Draw = 850mA Total System Draw = 975mA 24VDC MELR Module Draw = 700mA Total System Draw = 825mA Green (NC) White 3287 Door Position Switch 120 VAC Input Black (Hot) H N G 12/24VDC - + White (Neutral) Green (Gnd) Lockbody Power Supply (By Others) 12 Conductor ElectroLynx Harness From McKinney QC12 Electric Hinge From McKinney READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 0 - Green, 4 RX (NO/NC) - Orange, 5 RX (COM) - Blue, 6 *EGND - Brown, 7 LED - Yellow, 8 LOCK NEG - Violet, 9 LOCK POS - Gray, 10 (-) 12VDC (+) DATA 1 DATA 0 RX RX LED Use (NC) for Fail Safe Operation Electronic Access Control Panel (By Others) Lock Relay M802 Access 600 Series DPS DPS (NO) Fail Secure Operation, the global leader in door opening solutions 19 of 20 *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. Copyright 2016 Corbin Russwin Inc., an Group company.

20 9 Mechanical Operational Check For devices without cylinders, go to Section 6: Step C. 1. For devices with cylinders, insert key into cylinder and rotate. 2. The key will retract the latch and rods, the key should rotate freely. 10 Electrical Operational Check Note: Once electrical wiring has been successfully completed according to proper application, complete the following steps: 1. Turn power ON. 2. Verify LED located on reader is ON. Red or Green depending on reader configuration (See reader LED Configuration). 3. Present proximity credential and verify LED and sounder activity. 4. Verify valid card read at EAC Panel. 5. Verify system operation functions; i.e., when credential is presented to reader that the door unlocks. (Figure 22). Fig. 22 Corbin Russwin 225 Episcopal Road Berlin, CT Phone: WIRE Fax: corbinrusswin.com Copyright 2016 Corbin Russwin Inc., an Group company. 20 of 20, the global leader in door opening FM437 solutions (08/16)

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option Attention Installer FM313 6/09 (617417060) Please read these instructions carefully to prevent missing important

More information

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction) Installation Instructions MP9800 Series Multi-Point Lock MP9800 Series Multi-Point Lock, the global leader in door opening solutions 1 of 20 Copyright 2016 Corbin Russwin Inc., an Group company. Table

More information

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option Attention Installer FM312 6/09 (617419050) Please read these instructions carefully to prevent missing important

More information

ELR Series Multi-Point Lock Installation Instructions

ELR Series Multi-Point Lock Installation Instructions 7000 ELR Series Multi-Point Lock Installation Instructions Copyright 2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

Installation Instructions RF4510-EA

Installation Instructions RF4510-EA Installation Instructions RF4510-EA HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards Frequency

More information

IN120 WiFi. Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16

IN120 WiFi. Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16 IN120 WiFi Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16 Please read these instructions carefully to prevent missing important

More information

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset TM Access 800 FM223A 3/07 (617417410) Please read these instructions carefully to prevent missing important Steps. Please Note: Improper

More information

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset FM223 10/18 Please read these instructions carefully to prevent missing important Steps. Please Note: Improper installations may result

More information

Mortise Lockset IN100 with Aperio Technology Installation Instructions

Mortise Lockset IN100 with Aperio Technology Installation Instructions Mortise Lockset IN100 with Aperio Technology Installation Instructions Attention Installer FM403 07/16 Please read these instructions carefully to prevent missing important steps. Please Note: Improper

More information

Installation Guide(s)

Installation Guide(s) FCC Part 15 Transmitter Certification Test Report FCC ID: SPI-4XXKPMR FCC Rule Part: 15.09 ACS Report Number: 05-070-15C Manufacturer: Single Access Lock Inc. Model: 4XXKP/MR Installation Guide(s) 5015

More information

Automated Coupled Roller Shade Instruction Manual. link. Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount

Automated Coupled Roller Shade Instruction Manual. link. Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount Automated Coupled Roller Shade Instruction Manual link Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount WARNING: Read and understand all instructions to avoid damage or injury.

More information

TCPWI1/TCPIP1. Attention Installer

TCPWI1/TCPIP1. Attention Installer 700 TCPWI1/TCPIP1 Installation Instructions CL33700 TCPWI1 & TCPIP1Series Cylindrical Lockset FM323 4/16 Attention Installer Please read these instructions carefully to prevent missing important steps.

More information

IN100. with Aperio Technology. Mortise Lock Installation Instructions

IN100. with Aperio Technology. Mortise Lock Installation Instructions IN100 with Aperio Technology Mortise Lock Installation Instructions A8122A 6/12 Copyright 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or

More information

PASSPORT Cylindrical Lock Installation Instructions A8013H 04/16

PASSPORT Cylindrical Lock Installation Instructions A8013H 04/16 P2 PASSPORT 1000 Cylindrical Lock Installation Instructions A8013H 04/16 Copyright 2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part

More information

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18 v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18 Copyright 2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

Installation Instructions For Profile Series v.g1.5 Cylindrical Lock Installation Instructions For Profile Series v.g1.5 Cylindrical Lock A7854B Copyright 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in

More information

IN100. with Aperio Technology. Mortise Lock Installation Instructions A8190B 07/16

IN100. with Aperio Technology. Mortise Lock Installation Instructions A8190B 07/16 IN100 with Aperio Technology Mortise Lock Installation Instructions A8190B 07/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or

More information

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3) A. CHECKLIST (4 each AA Batteries Included) FOR DOOR AND FRAME PREPARATION INSTRUCTIONS, SEE APPENDIX A OR GO TO PROXESS.COM Parts List: Each Proxess C-Series lockset includes Exterior lock assembly (include

More information

IN100. with Aperio Technology. Cylindrical Lock Installation Instructions A8189B 07/16

IN100. with Aperio Technology. Cylindrical Lock Installation Instructions A8189B 07/16 IN100 with Aperio Technology Cylindrical Lock Installation Instructions A8189B 07/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole

More information

PASSPORT Cylindrical Lock. Installation Instructions A8033G 04/16

PASSPORT Cylindrical Lock. Installation Instructions A8033G 04/16 P1 PASSPORT 1000 Cylindrical Lock Installation Instructions A8033G 04/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part

More information

P

P P7639 Please keep this instruction sheet for future reference, as it contains important information. Requires four AA batteries (included) for operation. Adult assembly is required. Tool required for assembly:

More information

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

453X Series. Application. Features. Two-Position Damper Actuator General Instructions 453X Series Two-Position Damper Actuator General Instructions Application The 453L, light duty damper actuators are designed for a variety of two-position, spring return, damper applications. The 453L

More information

X0056. fisher-price.com

X0056. fisher-price.com X0056 Please keep this instruction sheet for future reference, as it contains important information. Adult assembly is required. Requires three button cell (LR44) alkaline batteries (included). Batteries

More information

PASSPORT Mortise Lock. Installation Instructions A8032G 04/16

PASSPORT Mortise Lock. Installation Instructions A8032G 04/16 P1 PASSPORT 1000 Mortise Lock Installation Instructions A8032G 04/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without

More information

www.fisher-price.com P6246 R2772 P6248 P6247 Each sold separately and subject to availability. Vehicles shown in illustrations may be different than the vehicle included with your toy. 1 Battery Installation

More information

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number: Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-247 ACS Project Number: 16-0295 Manufacturer: Itron, Inc. Model: OW1 Manual 5015 B.U. Bowman

More information

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI) Tractor Interface Module Installation Instructions Switch Input (TIM-SI) 821-7002 Installation Instructions Tractor Interface Module Switch Input (TIM-SI) 821-7002 Getting Started... 1 Installing the TIM...

More information

Press the buttons for fun sounds and music! fisher-price.com

Press the buttons for fun sounds and music! fisher-price.com K7189 Press the buttons for fun sounds and music! fisher-price.com Please keep these instructions for future reference, as they contain important information. Requires three button cell (LR44) batteries

More information

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions SECTION I: OVERVIEW 1. Description The Sargent 56- prefix ELR works with 80 Series exit devices to provide remote-controlled latch retraction. It is compatible with the following prefixes: 53 - Latchbolt

More information

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included). Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included). Adult assembly is required. Tool required for battery

More information

V9961 V9961

V9961 V9961 V9961 www.fisher-price.com Please keep this instruction sheet for future reference, as it contains important information. Adult assembly required. Requires one "AAA" battery (included). Tool required for

More information

Y9854. fisher-price.com

Y9854. fisher-price.com Y9854 Please keep this instruction sheet for future reference, as it contains important information. Requires two AA (LR6) alkaline batteries for operation (not included). Adult assembly is required. Tool

More information

V-D2425 and V-D2440 Digital Clock

V-D2425 and V-D2440 Digital Clock Installation Manual V1.03 V-D2425 and V-D2440 Digital Clock Valcom, Inc. V-D2425 and V-D2440 Wired Clock Table of Contents Table Installation of Contents 2 Instructions Flush Mount Installation 3 3 Wall

More information

W1392. fisher-price.com

W1392. fisher-price.com W1392 Please keep this instruction sheet for future reference, as it contains important information. Requires three C batteries (LR14) alkaline batteries (not included) for operation. Adult assembly is

More information

LED Recessed Troffer Retrofit Kit

LED Recessed Troffer Retrofit Kit Model # TRK series LED Recessed Troffer Retrofit Kit Installation Instructions PACKAGE CONTENTS A B E Part Item Name Qty. A Retrofit assembly 1 B Bracket 2 C Sheet metal screw 4 D Wire nuts 5 E Gap channel

More information

Yale Real Living Push Button Lever Installation and Programming Instructions

Yale Real Living Push Button Lever Installation and Programming Instructions Yale Real Living Push Button Lever Installation and Programming Instructions NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For

More information

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions T500 Series Non-Digital, On/Off Thermostat General Instructions Applications The T500 series thermostats are available in four basic models for low and line voltage control of valves, relays, and fan motors

More information

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries (included) for operation. Adult assembly is required. Tool required for battery

More information

BFK51 CFD40 CHM41. fisher-price.com

BFK51 CFD40 CHM41. fisher-price.com BFK51 CFD40 CHM41 Please keep this instruction sheet for future reference, as it contains important information. Requires three AA (LR6) alkaline batteries (not included). Adult assembly is required. Tool

More information

T

T T4262 Please keep this instruction sheet for future reference, as it contains important information. Maximum weight: 44 lbs. (20 kg). For ages between 9 months and 3 years. Requires three AA batteries

More information

HP10325 KIT. AMP Wireless Air Controls

HP10325 KIT. AMP Wireless Air Controls HP10325 KIT AMP Wireless Air Controls Take control of your air springs through the AMP Wireless Control application. Requires Air Springs and Onboard Air Systems (sold separately). + Download_on_the_ Download_on_the_

More information

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun X2916 Overhead Gym Tummy Time Fun WARNING To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. Please keep this instruction sheet

More information

T6339. Remove the mobile from the hub and clip to a stroller for on-the-go entertainment!

T6339. Remove the mobile from the hub and clip to a stroller for on-the-go entertainment! T6339 Remove the mobile from the hub and clip to a stroller for on-the-go entertainment! Please keep this instruction sheet for future reference, as it contains important information. Requires four AA

More information

W

W W0275 Actual product may vary from the photos. Please keep this instruction sheet for future reference, as it contains important information. Requires four "AA" (LR6) alkaline batteries (not included)

More information

WARNING. To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym.

WARNING. To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. X7299 WARNING To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. Please keep this instruction sheet for future reference, as it

More information

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk W9740 2 Ride 1 Sit 3 Walk Please keep this instruction sheet for future reference, as it contains important information. For ages 9 36 months and up to 44 lbs (20 kg). Adult supervision is required. Never

More information

W9740. Ride. Sit. Walk. fisher-price.com

W9740. Ride. Sit. Walk. fisher-price.com W9740 Ride Sit Walk Please keep this instruction sheet for future reference, as it contains important information. For ages 9 36 months and up to 44 lbs (20 kg). Adult supervision is required. Never use

More information

HOMELINK DOOR OPENER KIT

HOMELINK DOOR OPENER KIT HOMELINK DOOR OPENER KIT P/N 2882082 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain

More information

W3599

W3599 www.fisher-price.com W3599 Please keep this instruction sheet for future reference, as it contains important information. Requires two "AAA" batteries (included) for vehicles. Requires six "AAA" (LR03)

More information

XM Series. Quick Start Guide. Technology at Work XMCom9

XM Series. Quick Start Guide. Technology at Work XMCom9 XM Series Quick Start Guide Technology at Work. 062411XMCom9 Copyright 2011 Janam Technologies LLC. All rights reserved. XM Series, Janam and the Janam logo are trademarks of Janam Technologies LLC. Other

More information

X7298. fisher-price.com WARNING

X7298. fisher-price.com WARNING X7298 WARNING To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. Please keep this instruction sheet for future reference, as it

More information

T Overhead Gym. Tummy Time Fun. On-the-Go Fun

T Overhead Gym. Tummy Time Fun. On-the-Go Fun T6339 Please keep this instruction sheet for future reference, as it contains important information. Requires four AA (LR6) alkaline batteries for operation (not included). Tool required for battery installation:

More information

R

R R3858 Please keep this instruction sheet for future reference, as it contains important information. Adult assembly is required. Tools required for assembly: Phillips Screwdriver, Hammer and Scrap Block

More information

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required. www.tomy.com Thank you for purchasing a Chuggington Brewster s Big City Adventure Playset! SKU# LC54225 Please retain these instructions for future reference. Adult assembly required. 1 CONTENTS TTS TRACK

More information

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System U.S. Patent No. 7,04,050 For assistance, contact SARGENT

More information

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions *44487296* M400 Series 44487296 Single Electromagnetic Locks: M420, M450, M490 Installation Instructions M420/M450 Armature plate assembly M490 Armature plate assembly Features Automatic Voltage Selection

More information

P Volt Charger Each sold separately and subject to availability.

P Volt Charger Each sold separately and subject to availability. P6828 6-Volt 4 Amp/Hr Battery P6829 6-Volt Charger Each sold separately and subject to availability. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS. For use with a Power Wheels toddler vehicle

More information

& Mattel and Smart Toy LLC. All Rights Reserved. and designate U.S. trademarks of Mattel, except as noted. DNV

& Mattel and Smart Toy LLC. All Rights Reserved. and designate U.S. trademarks of Mattel, except as noted. DNV 1 UNITED STATES 1-800-432-5437 Fisher-Price, Inc. 636 Girard Avenue, East Aurora, NY 14052 Hearing-impaired consumers: 1-800-382-7470 CANADA 1-800-432-5437 Mattel Canada Inc. 6155 Freemont Blvd. Mississauga,

More information

Cab Control Operators Manual

Cab Control Operators Manual Cab Control Operators Manual Cab Control 2400 Cab Control 3400 Cab Control 3600 Ft. Atkinson, Wisconsin USA Panningen, The Netherlands www.digi-star.com D3820-US Rev B June 21, 2013 Table Of Contents Cab

More information

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case.

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case. Installation Instructions ED3200/ED3200A Series Rim Exit Device In U.S.: Corbin Russwin, Inc. 225 Episcopal Road Berlin, CT 06037 USA www.corbinrusswin.com In Canada: Door Security Solutions Canada 160

More information

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL The 5100 series lock is a stand-alone, microprocessor controlled, electromechanical locking system. The 5100 employs a heavy-duty mechanical design which is easy to install and highly reliable. The FSE

More information

MA40-704X Series MA41-707X Series MA41-715X Series

MA40-704X Series MA41-707X Series MA41-715X Series MA4-74X Series MA4-77X Series MA4-75X Series SmartX Actuators Spring Return Two-Position General Instructions Application SmartX Direct Coupled Actuators are designed to be used in both damper and valve

More information

Apple, iphone and ipad are trademarks of Apple Inc., registered in the U.S. and other countries. Android is a trademark of Google Inc.

Apple, iphone and ipad are trademarks of Apple Inc., registered in the U.S. and other countries. Android is a trademark of Google Inc. 1 UNITED STATES 1-800-432-5437 Fisher-Price, Inc. 636 Girard Avenue, East Aurora, NY 14052 Hearing-impaired consumers: 1-800-382-7470 CANADA 1-800-432-5437 Mattel Canada Inc. 6155 Freemont Blvd. Mississauga,

More information

Touchstone TB130 DC Output UPS

Touchstone TB130 DC Output UPS Touchstone TB130 DC Output UPS User Guide Release 2.5 STANDARD 1.0 August 2017 August 2017 Touchstone TB130 DC Output UPS User Guide Release 2.5 STANDARD 1.0 ARRIS Copyrights and Trademarks 2017 ARRIS

More information

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE 74212 USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE FEIT ELECTRIC COMPANY PICO RIVERA, CA (800) 543-3348 FAX (562) 908-6360 www.feit.com Table of Contents

More information

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 DEVICES COVERED IN THESE INSTRUCTIONS: RX Request to Exit ELECTRICAL SPECIFICATIONS Note: SPDT mechanical

More information

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278 MONOPRICE Power Cache 220 Solar Power Generator P/N 15278 User's Manual SAFETY WARNINGS AND GUIDELINES Do not expose this device to water or moisture of any kind. Do not place drinks or other containers

More information

- Wiring Brochure Mixing Expansion Module 440

- Wiring Brochure Mixing Expansion Module 440 - Wiring Brochure Mixing Expansion Module 440 W 440 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

RIDESENSE User Manual

RIDESENSE User Manual RIDESENSE User Manual RIDESENSE overview: The GIANT RIDESENSE employs ANT+ and Bluetooth Smart (BLE 4.0) license certification technology. ANT+: ANT+ certification compliant meter. Bluetooth Smart (BLE

More information

Hendrickson Fit Adapter Installation Instructions

Hendrickson Fit Adapter Installation Instructions Hendrickson Fit Adapter Installation Instructions Hendrickson Fit Adapter (HFA) Installation Manual Table of Contents Pre-Installation Requirements... 3 Clocking Wheels...3 HFA Hubcap Installation... 4

More information

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E INSTALLATION INSTRUCTIONS CRL JACKSON 2085E ELECTRIC LATCH RETRACTION CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com

More information

Wiegand & 2-Channel Relay Board

Wiegand & 2-Channel Relay Board Wiegand & 2-Channel Relay Board Installation Manual For Technical Support, Please CAll: 1-888-528-7826 www.chamberlainaccess.com Thank you for purchasing the Wiegand & 2-Channel Relay Board. While every

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US User s Manual ATTILA THE ANKYLOSAURUS TM TM 2012 VTech Printed in China 91-002772-000 US Hi Friend, You re about to embark on a dino-mite adventure with me, Attila the Ankylosaurus! Just so you know, I

More information

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION *921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications

More information

F261 Series Fluid Flow Switches

F261 Series Fluid Flow Switches F261 Series Fluid Switches Product Bulletin Code No. LIT-12011987 Issued March 9, 2015 The F261 Series Switches respond to fluid flow in lines carrying water, ethylene glycol, or other nonhazardous fluids.

More information

H3-EM Electronic Swinghandle Operating Instructions

H3-EM Electronic Swinghandle Operating Instructions H3-EM-67-100 Electronic Swinghandle Operating Instructions Package Contents H3-EM-67-x00 Electronic Swinghandle with Proximity Reader (qty1) EM-0-45827 M3x25 POZIDRIV Mounting Screws (qty 4) EM-0-47151

More information

Learn & Discover Driver TM

Learn & Discover Driver TM User s Manual Learn & Discover Driver TM 2012 VTech Printed in China 91-002724-000US TM INTRODUCTION Thank you for purchasing the VTech Learn & Discover Driver TM learning toy! Take a spin down the learning

More information

INSTALLATION GUIDE Confidant RFID Kit 1. 3rd party Rose Mount & Back Plate PK3616

INSTALLATION GUIDE Confidant RFID Kit 1. 3rd party Rose Mount & Back Plate PK3616 INSTALLATION GUIDE Confidant RFID Kit 1 3rd party Rose Mount & Back Plate PK3616 Confidant RFID TM Installation Instructions (Kit 1) IMPORTANT: Wear Safety glasses before starting the replacement of parts.

More information

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions MS40-77X Series DuraDrive Series Spring Return Proportional Actuators General Instructions Application DuraDrive Direct Coupled Actuators are designed to be used in both damper and valve control applications.

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US User s Manual TM HORNS THE TRICERATOPS TM 2012 VTech Printed in China 91-002679-005 US Hi Friend, You re about to embark on a dino-mite adventure with me, Horns the Triceratops! Just so you know, I ve

More information

7100SZ Series SafeZone Installation and Instruction Manual

7100SZ Series SafeZone Installation and Instruction Manual 7100SZ Series SafeZone Installation and Instruction Manual Patent Pending 80-9371-0081-00 (10-10) Pull Side Applications with Slide Track (7110SZ, 7150SZ) (see page 5 for template) 3 1 Push Side Applications

More information

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions MS4-634X Series SmartX Actuators Non-Spring Return Proportional General Instructions Application Direct Coupled SmartX Actuators are designed to be used in both damper and valve control applications. The

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information. Two-Way FM LED Remote System AS-RFK2315 User Guide Available functionalities depend on vehicle. Consult your dealer for more information. Designed & engineered in Canada INDUSTRY CANADA USER NOTICE: Operation

More information

Entry. Entry. Entry. Entry

Entry. Entry. Entry. Entry Functions x 9800/9M800 AC2 Exit Device Outside Inside Series/Function Type Function Description ED5200(A) & ED5200S(A) *9833 Without Cylinder Outside lever locked (freewheeling) except when in passage

More information

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57 User s Manual 2013 VTech Printed In China 91-002805-014 US CA 6700-201 Manual new.indd 1 2013/6/6 10:41:57 Dear Parent, Smart Wheels fun as well. Go! Go! Smart Wheels Go! Go! Go! Go! Smart Wheels features

More information

Bear s Baby Laptop TM

Bear s Baby Laptop TM User s Manual Bear s Baby Laptop TM 2013 VTech Printed in China 91-002821-000US INTRODUCTION Thank you for purchasing the VTech Bear s Baby Laptop TM learning toy! Bear s Baby Laptop TM encourages little

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

9700/F9700 SERIES RIM EXIT DEVICE

9700/F9700 SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS 9700/F9700 SERIES RIM EXIT DEVICE Index: Screw chart Tools required Outside trim options "03" Additional door prep Device installation Options available 5300 retro-fit preparation

More information

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 335 - Wiring Brochure W 335 12/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications Rough-in Wiring Rough-in wiring instructions 3 4 Wiring

More information

BFT56 CKB84. fisher-price.com. Keep this instruction sheet for future reference, as it contains important information.

BFT56 CKB84. fisher-price.com. Keep this instruction sheet for future reference, as it contains important information. BFT56 CKB84 Keep this instruction sheet for future reference, as it contains important information. Battery installation is required. Only adults should install batteries. Tool required for battery installation:

More information

User s Manual AKUNA THE VELOCIRAPTOR VTech Printed in China US

User s Manual AKUNA THE VELOCIRAPTOR VTech Printed in China US User s Manual AKUNA THE VELOCIRAPTOR TM 2013 VTech Printed in China 91-002813-000 US Hi Friend, You re about to embark on a dino-mite adventure with me, Akuna the Velociraptor! Just so you know, I ve been

More information

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1 Installation Manual for Off Line Systems INTELLIKEY is a trademark of INTELLIKEY Corporation 100419-GID 04/25/2003 Page 1 Page 2 Attention Installer If installation instructions are not followed this may

More information

CL3300 Series. Cylindrical Lockset Parts Manual

CL3300 Series. Cylindrical Lockset Parts Manual CL3300 Series Cylindrical Lockset Parts Manual Table of Contents Mechanical Drawing...3 Chassis & Buttons...4 Spring Housing Assemblies...5 Roses/Liners and Misc...6 Latches...7 Strikes...8 Standard Levers

More information

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY Issue 6 VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-6124 and VP-6124-E, 24Volt Power

More information

Security and Keyless Entry Installation Guide ca 1051

Security and Keyless Entry Installation Guide ca 1051 PROFESSIONAL SERIES Security and Keyless Entry Installation Guide ca 1051 ca1051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection

More information

*504471* Instruction Manual for the. Akrapovič Sound Kit. Sound Remote Controller and Akrapovič Car Sound Kit App Manual FOR CARS

*504471* Instruction Manual for the. Akrapovič Sound Kit. Sound Remote Controller and Akrapovič Car Sound Kit App Manual FOR CARS Instruction Manual for the Akrapovič Sound Kit *504471* Sound Remote Controller and Akrapovič Car Sound Kit App Manual FOR CARS Ver 1.2 / January 2016 Akrapovič Sound Kit CONGRATULATIONS Congratulations

More information