XCM12 Mini-Centrifuge
|
|
- James McKinney
- 5 years ago
- Views:
Transcription
1 Multi-speed Digital User Manual v. 1.0 C&A Scientific
2 Disclaimer C & A Scientific owns the copyright of this user manual. No person shall reprint or distribute the contents of this user manual, including pictures, drawings, and related audio and video products. C & A Scientific has no obligation and responsibility for any damages caused by users who do not follow the operating instructions, safety precautions, and maintenance recommendations of this user manual. C & A Scientific has the right to modify the contents of the Operating instructions section at any time without notice. C&A Scientific i
3 Table of Contents XCM12 Mini-Centrifuge 1 Introduction Packing list Product components Product inspection Technical specifications Safety and operating environment Safety precautions Operating environment Operating instructions Power Rotors Tubes Tube preparation Load tubes Start Select speed and time Calculate centrifugal force Stop Cleaning, storage, and maintenance Cleaning Remove and clean rotor Storage Maintenance Repair and maintenance record Troubleshooting and support Troubleshooting Support Warranty Warranty Scope Quality Certificate Product Certificate C&A Scientific ii
4 1 Introduction The XCM12 Mini-Centrifuge adopts international advanced design and manufacturing technology, featuring a compact structure and simple operation. This tabletop centrifuge is suitable for the following purposes: Microtubule filtration Fast centrifugation Micro blood cell separation Microbial sample processing Experimental partition centrifugal of PCR Important: Before first use, read this manual for operating, safety, and other instructions and information. 1.1 Packing list Item Description Quantity Note 1 Centrifuge 1 2 Power cord 1 AC V/50/60Hz 3 Rotors 5 4 Adapters 28 1 piece each: 1.5/2.2 ml x 12 + PCR 2 ml x 8 x 4 rows Angle PCR rotor 2 ml x 12 x 4 rows Angle rotor 5 ml x 4 Angle hematocrit rotor 40 mm x 12 (written hematocrit x 12) Angle 5.1/ 8.1 ml x 4 1.5ml (1 package of 4) 0.5ml (1 package of 12) 0.2ml (1 package of 12) 5 Warranty 1 12 months from day of receipt 6 Certificates 1 7 Operating instructions 2 Packing Staff: 1 each: Quality certificate Product certificate 1 each: User Manual Quick Start Guide Inspector: Date: Date: C&A Scientific 1-1
5 1.2 Product components Figure 1 Unit (Centrifuge) XCM12 Mini-Centrifuge 1. Cover 2. Upper chassis 3. Rotor 4. LCD display 5. Base chassis 6. Foot 7. Latch Figure 2 Cover 8. Cover tab Figure 3 Power button and plug (back of unit) 9. Power button 10. AC V/50/60Hz power plug C&A Scientific 1-2
6 Figure 4 LCD display 1. Menu (used for changing speed and time) 2. Speed display (x 10rpm) 3. Increase button 4. Cover open indicator 5. Time display 6. Decrease button 7. Start/Stop button 8. Operation indicator 9. Cover closed indicator 10. Time unit 1.3 Product inspection After opening the packaging, immediately inspect the unit and accessories for any manufacturer defects or damage during shipping. If the unit is not the model you ordered or is somehow not consistent with your order, immediately contact C & A Scientific. Do the following: Remove all packing materials Ensure the exterior of the unit has no clear damage Pull the cover tab on the cover to open it. Ensure the cover opens easily with no abnormal sound. Ensure the rotor is vertical and fits tightly on the motor shaft. Ensure the Power button and Power Plug are firmly fixed on the back of the unit. If either is loose, do not use the unit and immediately contact C & A Scientific. If the unit and accessories pass your inspection, the machine is safe for use. Before use, read all C&A Scientific 1-3
7 Category Environment of use Electric Source Input Ambient Temperature Display Time Speed [r/min.] Maximum relative centrifugal force Max tube length Specification Clean, dry, and ventilated Altitude: 2000m Relative humidity: 80% AC230V 50HZ/60HZ +5 C~-40 C LED display 1 Hr 59 min 59 sec 4000r/min 3040 X g 40mm X 135mm Max capacity 50mL X 4 Unit dimensions 23 X 18 X 14 Unit weight 66 pounds Carton dimensions 25 X 21 X 17 Carton weight 76 pounds Noise 65dB(A) Recommended Temperature/Humidity F/80% Test Value EN ,EN ,EN ,EN /A2 Rotor Capacity (ml x tube) Speed (r/min) RCF (x g) Tube Rotors #1Square rotor 1.5/2.2 ml 12 + PCR 0.2 ml 8 4 rows PCR 0.2 ml 12 4 rows PP Conical w/cover #2 Angle PP Conical PCR w/cover #3 Angle 5 ml PP Conical w/cover #4 Angle Hematocrit D 1.5 mm 40 #5 Angle 5/1.8/1.1 ml PP Screw w/stand C&A Scientific 1-4
8 Safety and operating environment and Operating instructions. If the unit and accessories did not pass inspection or you are missing parts or accessories, contact C & A Scientific. Do not attempt repair without professional guidance from the manufacturer or C & A Scientific! C&A Scientific 1-5
9 1.4 Technical specifications XCM12 Mini-Centrifuge Category Environment of use Electric Source Input Ambient Temperature Display Time Speed [r/min.] Maximum relative centrifugal force Max tube length Specification Clean, dry, and ventilated Altitude: 2000m Relative humidity: 80% AC230V 50HZ/60HZ +5 C~-40 C LED display 1 Hr 59 min 59 sec 4000r/min 3040 X g 40mm X 135mm Max capacity 50mL X 4 Unit dimensions 23 X 18 X 14 Unit weight 66 pounds Carton dimensions 25 X 21 X 17 Carton weight 76 pounds Noise 65dB(A) Recommended Temperature/Humidity F/80% Test Value EN ,EN ,EN ,EN /A2 Rotor Capacity (ml x tube) Speed (r/min) RCF (x g) Tube Rotors #1Square rotor 1.5/2.2 ml 12 + PCR 0.2 ml 8 4 rows PCR 0.2 ml 12 4 rows PP Conical w/cover #2 Angle PP Conical PCR w/cover #3 Angle 5 ml PP Conical w/cover #4 Angle Hematocrit D 1.5 mm 40 #5 Angle 5/1.8/1.1 ml PP Screw w/stand C&A Scientific 1-6
10 2 Safety and operating environment Before first use, read this manual for operating, safety, and other instructions and information. Neglect of safety and environmental operation procedures, laws, regulations, and other governing rules and guidelines of the country and the locality of the installation can cause harm to personnel, the unit, and the environment. To avoid damage to surrounding objects, personnel, and environments, comply with all safety and operating environment instructions in this user manual. The use of the following materials is prohibited with the unit: Flammable and explosive materials Strong chemicals Toxic or radioactive substances Pathogenic microorganisms Use C & A Scientific accessories. C & A Scientific is not responsible for damage caused by use of accessories from other suppliers. Only authorized personnel using appropriate tools may repair the unit. Failure to comply will void the warranty. 2.1 Safety precautions It is strictly prohibited to: Plug in or unplug the power cord while the Power button is ON Plug in or unplug the power cord and switch the power ON or OFF with wet hands Scrub the instrument and clean the machine while the Power button is ON Danger! High Voltage! The risk of electric shock! Operate with samples greater than 70% capacity of each test tube Place the unit on an unstable surface Use a hand or other object to stop the motor 2.2 Operating environment The unit must be used: Indoors only and away from water sources In a room fitted with adequate ventilation C&A Scientific 2-7
11 At an altitude of 7,000 feet (2,100 meters) or less At a working environmental temperature range of +41 to +104 F (+5 to +40 ) With a relative humidity of 80% or less Keep the unit away from: Vibration and air flow that may influence performance Conductive dust, explosive gas, and corrosive gases in the ambient air These factors may damage the centrifuge: Strong chemicals Environmental impacts, including natural ultraviolet radiation Wear and tear or corrosion of the parts of the protective cover and other components 3 Operating instructions 3.1 Power 1. Plug the Power cord into the power supply. Danger! High Voltage! The risk of electric shock! 2. On the back of the unit, switch the Power button ON. Figure Rotors 1. Pull the Cover tab to open the cover. 2. Align the center of the rotor (A) with the shaft (B), as shown in Figure 6, and press down until it clicks, indicating that the rotor is locked. C&A Scientific 3-8
12 Figure 6 3. Grasp the rotor and gently lift it upward to verify it locked. For information about removing the rotor, see Remove and clean rotor. 3.3 Tubes Tube preparation Ensure that: You use 0.2ml, 0.5ml, or 1.5ml sized tubes. If you have different sized tubes, use the adapters to ensure a secure fit in the rotor. Each tube has an equal amount of liquid by weight Each tube contains 70% or less of the tube s capacity. Do not fill tubes to capacity. You have an even number of tubes. This enables proper rotor balance. Load tubes If your sample matter does not fill each tube (you have an odd number of tubes), place a comparable substance (by weight) in a tube to create an even number of tubes. 1. Load filled tubes and any adapters into the rotor slots, ensuring that the rotor is symmetrically balanced with tubes. Note: When using the PCR rotor, all slots must be filled. C&A Scientific 3-9
13 3.4 Start XCM12 Mini-Centrifuge Important: Carbon deposits may have settled during shipping, which can cause friction and vibration when running. When using the unit for the first time, run it without tubes for 2-3 minutes on low speed to adjust and stop any vibration. 1. Close the cover until you hear a click. The centrifuge will not operate unless the cover is closed. Note: If the cover opens while running, the spinning slows and the E3 error displays. Select speed and time Figure 7 1. Press the Menu button. The Speed display flashes. 2. To change the speed, press the Increase or Decrease buttons. Pause to save the setting. For information about calculating centrifugal force, see Calculate centrifugal force. 3. Press the Menu button. The Time display flashes. 4. Optionally, to change the time unit from minutes to seconds, when the time is set at 1 minute, press the Decrease button. Pause to save the setting. 5. To change the time, do one of the following: Note: You can select from 1 to 59 seconds or 1 to 99 minutes. If you changed the time unit, press the Menu button again, then press the Increase or Decrease buttons. Pause to save the setting. If you did not change the time unit, press the Increase or Decrease buttons. Pause to save the setting. 6. Press the Start/Stop button. Note: You cannot change the speed selection while the cycle is running. C&A Scientific 3-10
14 Calculate centrifugal force XCM12 Mini-Centrifuge Relative centrifugal force is used to measure the efficiency of a variety of instrument separation or precipitation. The calculation of centrifugal force involves centrifugal speed and centrifugal radius. The centrifugal force setting should consider the radius of the rotor and the shape of the centrifugal container. based on the following equation: RCF = (n/1000) ² r r is the centrifugal radius; unit is in centimeters n is the centrifugal speed; unit is in RPM (revolutions per minute) 3.5 Stop 1. Press the Start/Stop button but do NOT open the cover. The unit will stop spinning in a few seconds. Do not use your hand or other objects to stop the motor! 2. After the unit has stopped spinning, pull the Cover tab and lift the cover. 3. On the back of the unit, switch the Power button off. 4. Remove all tubes. 5. Clean the unit and accessories if this is the last use of the day. 6. Close the cover when in storage. 4 Cleaning, storage, and maintenance Frequent and proper cleaning will help ensure a long product lifespan. If you plan to return the unit or accessories to C & A Scientific or if professional maintenance is required, before returning it, you must ensure all equipment is properly cleaned and cannot cause harm to the human body. When performing maintenance or cleaning the centrifuge, ensure the power is switched OFF or the unit is unplugged. 4.1 Cleaning Weekly exterior and rotor cleaning is usually sufficient. However, clean immediately after use if using chemicals for techniques such as extraction, separation, purification or other cell degradation techniques. If the equipment or accessory is polluted with pathogenic, toxic, or radioactive substances, proper cleaning is your responsibility. Consult your laboratory's biosafety guidelines for further instruction. C&A Scientific 4-11
15 If the unit requires cleaning and decontamination not mentioned in this user manual, follow your laboratory s cleaning and safety guidelines. 1. Carefully wipe the surface of the unit using a soft cloth with a neutral detergent. Remove the detergent residue with a clean, damp cloth. Do not use: Organic solvents: They can break down the motor bearing's lubricating oil. Do not let liquid, especially organic solvents, touch the motor spindle and inner bearing ball. Sharp instruments: They can scratch the unit or cause injury. Remove and clean rotor 1. Place thumbs on each side of the rotor snaps and press inward, as shown in Figure 8. Figure 8 2. Grip the rotor firmly and lift vertically to remove it from the shaft. Do not wiggle the rotor from side to side or use strong force as this may damage the rotor, shaft, and motor. Handle the rotor with care to prevent damage. 3. To clean, use a moistened sponge or cotton cloth with a neutral, non-abrasive detergent, then wash with distilled water. Do not sprinkle or spray the rotor with water as liquid may remain and cause corrosion. 4. After cleaning, dry the rotor upside down on a clean surface. 4.2 Storage When in storage, ensure the unit is powered OFF or unplugged. Store the rotors and accessories in the bag that shipped with the unit. To prevent dust and other contamination, ensure the unit is properly cleaned, the cover is closed, and you place the unit in the bag that shipped with it. C&A Scientific 4-12
16 4.3 Maintenance XCM12 Mini-Centrifuge When performing maintenance or cleaning the centrifuge, ensure the power is switched OFF or the unit is unplugged. Check the rotor on a regular basis for corrosion, pits, grooves, and small cracks. If found, discontinue use of the rotor and contact C & A Scientific. Ensure the cover opens and closes smoothly. If a major problem occurs, such as the unit does not operate properly with the power supply, a burnt smell emerges from inside the machine, a rotor breaks, or the unit shakes violently while running, immediately discontinue use and contact C & A Scientific. Do not attempt repair without the guidance of an authorized professional! Repair and maintenance record C&A Scientific 4-13
17 5 Troubleshooting and support The table below list causes and solutions for commonly known issues. Contact C & A Scientific if you still cannot resolve an issue after troubleshooting. If an issue occurs, turn the power off, unplug the unit, troubleshoot, and then start the unit again. 5.1 Troubleshooting Issue Does not spin Sudden stop during operation LCD display does not light Causes and Solutions Check the AC V/50/60Hz power plug and power cord for damage Ensure your power outlet is functioning Ensure the Power button can turn ON and OFF The lid opened. Close the lid before starting the operation again. Power supply connection issue. Motor overheated or overloaded; turn the power off and wait minutes to restart If there is a burning smell, immediately unplug the power supply and contact C & A Scientific Voltage range might be excessive; check that the supply voltage is in accordance with provisions of AC V/50/60Hz Not connected to the power supply: check the Power plug, Power cord, and the power connection Press the Menu button and Increase and Decrease buttons to test each display area Button not responding Contact C & A Scientific Not listed here Contact C & A Scientific 5.2 Support C & A Scientific Service and support contact (U.S.): sales@cnascientific.com or (703) If you plan to return the unit or accessories, you must ensure all equipment is properly sanitized and cannot cause harm to the human body. C&A Scientific 5-14
18 6 Warranty The warranty period begins upon your receipt of the product and expires 12 months after the day of receipt. In the warranty period, if the product fails, contact C & A Scientific. If failure is due to a faulty part or manufacturing defect, the product will be repaired or replaced. If failure is due to improper use, repair or replacement is not the responsibility of C & A Scientific. Damage to the housing (outside plastic dome or rotors) is not covered under warranty. After the warranty period expires, C & A Scientific is not responsible for the cost of any repair or replacement. After the warranty period expires, you may still request repair from the manufacturer or C & A Scientific at your own expense. 6.1 Warranty Scope The user must operate and maintain the product according to the requirements and instruction presented in this user manual. Modification, adjustments (including changes in electrical components), and other changes from the intended design may only be conducted by the manufacturer or C & A Scientific. In the event you do not meet the above requirements, any damage caused by misuse will be repaired by the manufacturer or C & A Scientific at your expense. C&A Scientific 6-15
OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified
OPERATIONS MANUAL Mini Centrifuge Model MCF-2360 Certified Contents 1. Safety 2 2. Introduction 7 3. Package Contents 7 4. Specifications 8 5. Features 8 6. Parts of the Mini Centrifuge 9 7. Installation
More informationBio Lion Table Top Centrifuge XC-L5
Bio Lion Table Top Centrifuge XC-L5 Operation Manual Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting
More informationOperating Manual Cellspin
Operating Manual Cellspin Clinical Centrifuge Date of Purchase Serial No. Place of purchase Copyright 2017 Hanil Scientific Inc. All rights reserved. Contact Us If you have and questions, contact Hanil
More informationOperation Manual Supra R22
Operation Manual Supra R22 High speed Centrifuge Copyright c 2017 Hanil Scientific Inc. All rights reserved. Contact Us If you have any questions, contact Hanil Scientific Inc. or place of purchase. info@ihanil.com
More informationBio Lion Table Top Centrifuge XC-H165
Bio Lion Table Top Centrifuge XC-H165 Operation Manual Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting
More informationBT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT
BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4
More informationINSTRUCTION MANUAL. CAT Place Table Top Centrifuge
1 INSTRUCTION MANUAL CAT. 72359-06 6-Place Table Top Centrifuge 2 CONTENTS IMPORTANT SAFETY GUIDELINES PLEASE READ BEFORE USE.. 3 SUPPLIED EQUIPMENT... 5 OPTIONAL ACCESSORIES... 5 SETUP... 5 UNPACKING...
More informationNANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500
NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction
More informationGLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd
Benchtop Centrifuge GLO GT416 User s Manual Glotech Co., Ltd Contents 1. GLO GT416G Performance 2. Precautions 3. Technical Specifications 4. Installation 4 1. Delivery Checklist 4 2. Unpacking the Instrument
More informationInstruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge
Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards
More informationInstruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge
Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards
More informationInstruction Manual. Labnet Spectrafuge 16M Microcentrifuge
Instruction Manual Labnet Spectrafuge 16M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com Safety Precautions NEVER
More information1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.
Multi-Purpose, High Speed Centrifuge 1580R User s Manual Gyrozen Co., Ltd. B Station, 30-12 Gyeryong-ro 141-gil, Yuseoung-gu, Daejeon 305-301, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 www.gyrozen.com
More informationD2012 & D2012 plus High Speed Mini Centrifuge
D2012 & D2012 plus High Speed Mini Centrifuge DLAB Laboratory Instruments Limited USER MANUAL Before using centrifuge, please carefully read this user manual for its efficient operation and safety. Contents
More informationLumitester PD-20 Control Kit
日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully
More informationD3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited
D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited Before using centrifuge, please carefully read this user manual for its efficient operation and safety. USER
More information624R User s Manual. Compact Bench-Top Refrigerated Centrifuge
Compact Bench-Top Refrigerated Centrifuge 624R User s Manual Manufacturer: GYROZEN Co., Ltd. 30-12 Gyeryong-ro 141beon-gil, Yuseong-gu, Daejeon 34187, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 info@gyrozen.com
More informationSimple design with easy-to-use features
Simple design with easy-to-use features High Speed Refrigerated Centrifuge Model 7000 Compact High Speed Refrigerated Centrifuge Model 6000 Optional foot switch attachable for hands-free lid opening 2
More informationDM1424 Hematocrit Centrifuge
DM1424 Hematocrit Centrifuge SCILOGEX, LLC www.scilogex.com Before using centrifuge, please carefully read this user manual for efficient operation and safety. Contents Safety Reminder... 1 1. Specifications...
More information1236R User s Manual. Multi-Purpose, High Speed Centrifuge
Multi-Purpose, High Speed Centrifuge 1236R User s Manual Manufacturer: GYROZEN Co., Ltd. 30-12 Gyeryong-ro 141beon-gil, Yuseong-gu, Daejeon, 34187, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 info@gyrozen.com
More informationCONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection
1 PRODUCT DESCRIPTION 1.1 Usage in accordance with safety standards 1.1.1 General Information 1.1.1.1 Hazards and precautions 1.1.1.2 Brief description 1.1.1.3 Safety standards 1.1.1.4 Included items 1.1.1.5
More informationmaterials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:
WARRANTY The Drucker Company warranties that this centrifuge is free from defects in materials and workmanship for 2 years. Should the centrifuge require warranty or out-of-warranty service please contact:
More informationUSER MANUAL. D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC.
USER MANUAL D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC Before using centrifuge, please carefully read this user manual for efficient operation and safety. USER MANUAL Contents
More informationBlueSpin Cryo. (Cat. No. BSD-CRYO)
BlueLine Instruments for Electrophoresis INSTRUCTION MANUAL BlueSpin Cryo (Cat. No. BSD-CRYO) SERVA Electrophoresis GmbH - Carl-Benz-Str. 7 - D-69115 Heidelberg Phone +49-6221-138400, Fax +49-6221-1384010
More informationUSER MANUAL. D2012 High Speed Mini Micro-Centrifuge SCILOGEX, LLC.
USER MANUAL D2012 High Speed Mini Micro-Centrifuge SCILOGEX, LLC www.scilogex.com Before using centrifuge, please carefully read this user manual for efficient operation and safety. USER MANUAL Contents
More informationUser s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)
User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) EOW-LB100-PNUS2 Thank you for purchasing this product from Tabuchi Electric. Read this User s Manual carefully to ensure safe use of
More information40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /
ITEM #0506882 / 0506883 40 V LITHIUM-ION BATTERY MODEL #KB 240-06 / KB 440-06 Français p. 7 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date AB13786C 1 PRODUCT SPECIFICATIONS Battery
More informationDM0636 Multi-purpose Centrifuge
DM0636 Multi-purpose Centrifuge Before using centrifuge, please carefully read this user manual for its efficient operation and safety. Contents Copyright:... 0 Safety Reminder... 1[ 1. Specifications...
More informationModel : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment
HIGH SPEED CENTRIFUGES Instruction Manual Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment Before Installation The centrifuge can be damaged if connected
More informationRegister your instrument! MiniSpin /MiniSpin plus. Operating manual
Register your instrument! www.eppendorf.com/myeppendorf Operating manual Operating MiniSpin /MiniSpin see on Fig. Tab. p. p. manual plus Copyright 2015 Eppendorf AG, Germany. All rights reserved, including
More informationUltra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea
INSTRUCTION MANUAL Ultra 5.0 Manufactured By In Korea 2 Ultra5.0 Instruction Manual Contents 1. Introduction 2. Note for Installation 3. Parts Description - Specifications - Caution - Safety Devices -
More informationHigh Speed Micro-Centrifuge User manual
High Speed Micro-Centrifuge User manual 400.003.205 Centrifuge Supplied With Rotor 400.003.221 (24 x 1.5ml/2ml) 400.003.210 Refrigerated with Rotor 400.003.221 24x1.5ml/2ml 400.003.220 Rotor 5ml x 18 400.003.221
More informationHeavy-Duty Welding Fabrication Table
Heavy-Duty Welding Fabrication Table with Fix-Up Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and
More informationSIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions
SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
More informationVoltmaster Centrifugal Trash Pumps
Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2
More informationInstruction Manual for FI Controller
Instruction Manual for FI Controller Thank you for purchasing one of our TAKEGAWA s products. Please strictly follow the instructions to install and use the products. Before installing the products, please
More informationCentrifuge. Model XC-1000 Operating Manual
Centrifuge Model XC-1000 Operating Manual Before using this product, please read this manual carefully to learn about the available features to obtain the best results of this equipment. Warning: To prevent
More information110 Volt/12 Volt Portable Inflator
110 Volt/12 Volt Portable Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationPacked with new features
Packed with new features Simple design with new easy-to-use features NEW NEW High Speed Refrigerated Centrifuge Model 7000 Compact High Speed Refrigerated Centrifuge Model 6000 Optional foot switch available
More informationTissue Master. User Manual
Tissue Master User Manual This page left blank intentionally This manual is a guide for the use of the Omni International Tissue Master and accessories. Data herein has been verified and validated. It
More informationAngle Grinder Holder
Angle Grinder Holder Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More information12 Volt Heavy-Duty Air Inflator
12 Volt Heavy-Duty Air Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More informationOperation Manual. H6000 Series
Operation Manual H6000 Series Foreword Thank you for purchasing s Incu-Mixer MP. This user manual contains all pertinent information concerning the function and operation of the instrument. In order to
More informationClinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.
Clinical Centrifuge Before using centrifuge, please carefully read this user manual for efficient operation and safety. 49 Rue Gioffredo 06000 Nice Tél. +33.4.93.85.58.90 Fax. +33.957.333.256. info@a-prf.com
More information315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL
315W CMH COMPLETE GROW LIGHT SYSTEM [120-240V] USER MANUAL Enclosed Style Open Style IMPORTANT PRODUCT INFORMATION READ IMMEDIATELY SAFETY FIRST! Failure to observe the following safety warnings may result
More information60 Watt Industrial LED Low Bay Light
60 Watt Industrial LED Low Bay Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationAir-Operated Waste Oil Drainer
Air-Operated Waste Oil Drainer 20-Gallon Tank Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationINSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE
INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...
More information82V LITHIUM-ION BATTERY CHARGER GC 400
82V LITHIUM-ION BATTERY CHARGER GC 400 (2907302) Owner s Manual TOLL-FREE HELPLINE: 1-855-470-4267 www.greenworkstools.com/82v-commercial/ Read all safety rules and instructions carefully before operating
More informationSAVE THESE INSTRUCTIONS
12 Volt High-V Volume Air Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND A OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationMax. 22,000 rpm / 48,700 xg, full 3 liter capacity
Max. 22,000 rpm / 48,700, full 3 liter capacity Easy-to-use Compact Design (only 50cm wide) Features 3 Liter Capacity 6 x 500mL bottles can be centrifuged at 12,090. Auto Interlock Lid To close lid Push
More informationHeavy Duty Four Wheeled Walker
Heavy Duty Four Wheeled Walker Weight Capacity: 500 lbs. ITEM # W1802 Made in China 2011 ESSENTIAL MEDICAL SUPPLY, INC. Manufactured for Orlando, FL 32822 -- SAVE THESE INSTRUCTIONS -- Do not attempt to
More informationClinispin CT20 User Manual
Clinispin CT20 User Manual C0060-WOD-230EU Lit M00031 Rev 1 June, 2012 Safety Precautions NEVER NEVER NEVER NEVER NEVER NEVER NEVER NEVER ALWAYS ALWAYS ALWAYS ALWAYS use the centrifuge in any manner not
More informationAIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E
AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E TDG8000-3 TDG7000SE-3 TDG7000E TDG8000E TDGW7000SE TDG7000E3 TDGW8000E
More informationSTANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96
PAGE: 1 of 5 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 INTERFERENCES AND POTENTIAL PROBLEMS 4.0 EQUIPMENT/APPARATUS 5.0 PROCEDURE 6.0 QUALITY ASSURANCE/QUALITY CONTROL 7.0 HEALTH AND SAFETY
More informationCentrifuge. Model XC-2000 Operating Manual
Centrifuge Model XC-2000 Operating Manual Before using this product, please read this manual carefully to learn about the available features to obtain the best results of this equipment. Warning: To prevent
More informationIMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1
IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 2 MAIN COMPONENTS ITEMS INCLUDED SPRAYER TANK 6.8 VOLT BATTERY -3400 mah 6.8 VOLT CHARGER NOZZLE WRENCH TANK CAP
More informationOPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA
OPERATING MANUAL Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA Mega17R OPERATING SPECIFICATION Mega 17R MAX RPM MAX RCF MAX CAPACITY SPEED DISPLAY 17,000
More informationSPECTRAFUGE 6C. User Manual C0060 C V
SPECTRAFUGE 6C User Manual C0060 C0060-230V Lit M00031 Rev 2 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet Spectrafuge 6C Centrifuge. The manual
More informationAdjustable Steel Welding Table
Adjustable Steel Welding Table Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationUSER MANUAL PRF DUO. Clinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.
USER MANUAL PRF DUO Clinical Centrifuge Before using centrifuge, please carefully read this user manual for efficient operation and safety. 49, Rue Gioffredo 06000 Nice - France - Phone : +33.4.93.85.58.90
More informationElectric Chainsaw Sharpener With Bar Mount
Electric Chainsaw Sharpener With Bar Mount Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
More informationNavigator ORDERCODE 40410
Navigator ORDERCODE 40410 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Navigator brings excitement to any venue. Whether you want simple plug-&-play action or
More information16 Inch Surface Cleaner
16 Inch Surface Cleaner Owner s Manual WARNING: Read and understand all instructions, warnings, and cautions before using this product. Failure to follow the instructions, warnings, and cautions may result
More informationOperating Instructions. PowerMax. CORDLESS CAULKING GUN Modell: HPS-4C2-10.8V Li-Ion 380ml to 410ml (5:1)Coaxial Cartridges
Operating Instructions PowerMax CORDLESS CAULKING GUN Modell: HPS-4C2-10.8V Li-Ion 380ml to 410ml (5:1)Coaxial Cartridges Operational Precautions General Safety Instructions! WARNING 1. Consider work area
More informationPower-edge. Pro. User manual. Power-edge Pro User Manual
Power-edge Pro User manual Power-edge Pro User Manual 1 Congratulations on your purchase of a Power-edge Pro ski edge sharpening machine! Your Power-edge Pro will allow you to grind regular or hardened
More informationOPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.
Requires Manual Shut Off. 6 / 2 AMP,, DUAL RATE BATTER TTERY CHARGER 45005 OPERATING INSTRUCTIONS E224783 E224783 Note: 6V Charging Due to continuing improvements, actual product may differ slightly from
More informationSource Capture Air Purification System
Source Capture Air Purification System HA-SCP-G3 Owner s Manual Table of Contents HealthyAir HA-IFM-1111 Filter 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Packing
More information1200W CaR PoliSheR en RS4900
1200W Car Polisher RS4900 RS4900 8 1 2 7 3 4 5 6 A B flat nozzle C D E F 1200W Car Polisher RS4900 G H flat nozzle I J K L 4 1200W Car Polisher COMPONT LIST 1 2 3 4 5 6 7 Variable speed control Switch
More information18VDC ESB6 Series Cordless Screwdrivers Operation Manual
18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before
More informationSECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body
SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS Body Specifications 236 Protecting your vehicle from corrosion 237 Washing and waxing 238 Cleaning the interior 239 235 SPECIFICATIONS DIMENSIONS AND WEIGHT
More informationBATTERY & STARTER ANALYSER (BSA-12) User Manual
BATTERY & STARTER ANALYSER (BSA-12) User Manual Introduction BSA-12 Battery Starter Analyser does not carry internal batteries but is powered up from external DC source ranging from 9V to 15V DC. It is
More informationINSTRUCTION MANUAL ANGLE GRINDER PT W
INSTRUCTION MANUAL ANGLE GRINDER PT50360 4½ INCHES 120V 60Hz 600W 5A 12,000 rpm C US Note : Before operating this tool, read this manual and follow all safety rules and operating instructions. This electric
More informationCompact LED profile with zoom
Compact LED profile with zoom 2 11 TABLE OF CONTENTS SAFETY / GENERAL INSTRUCTIONS INTRODUCTION Features Specifications OVERVIEW Rear view Top view MOUNTING CONTROL MENU OVERVIEW Control Panel Function
More information1000-lb Hydraulic Truck Crane
1000-lb Hydraulic Truck Crane Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationGarden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual
Garden Hose Reel with 3/4In. x 100Ft. Hose Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
More informationMULTI-CHARGER FOR 12 TO 18V NI-CD OR LI-ION BATTERIES
MULTI-CHARGER FOR 12 TO 18V NI-CD OR LI-ION BATTERIES 054-3169-4 Owner s Manual Input: Output: Optimum charging temperature: Battery types: Charging times: Weight: PRODUCT SPECIFICATIONS 120 V, 60 Hz 18V
More informationDIGITAL RCD(ELCB) TESTER
INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.
More informationOperation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models , -25, -50, -55
Operation Manual Cole-Parmer MPR16 Multipurpose Refrigerated and MP16 Multipurpose Ambient Centrifuges Models 17406-20, -25, -50, -55 CE 1065z76_MAN_Rev.1 2016 Cole-Parmer Instrument Company, LLC Table
More informationRegister your instrument! HeatSealer S100. Operating manual
00N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2015 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication
More informationOWNER S OPERATING MANUAL
OWNER S OPERATING MANUAL MIG 100 GASLESS WELDER TABLE OF CONTENTS Page Safety instructions 3-4 MIG Welders 5 Welder Information 5 Gasless welder set up 6 Operation 6-10 Troubleshooting Guide 11-12 Spare
More informationMULTI-FUNCTION JUMP STARTER
MULTI-FUNCTION JUMP STARTER FEATURES 1. Flashlight 2. Jump Start Port 3. LED Power indicator 4. USB Output 5. Power button 6. Charging port 7. Car battery clamp 8. Home charger&car charger 9. Portable
More information182-LED Solar-Powered Motion Security Light. Owner s Manual
182-LED Solar-Powered Motion Security Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More information2-Pack Indoor Simulated Dome Security Cameras
2-Pack Indoor Simulated Dome Security Cameras Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationOPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.
OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. M.R.C.LTD. Hagavish 3 st. Israel 58817 Tel: 972 3 5595252, Fax: 972
More informationMulti-Purpose, High Speed Centrifuge 1248R/1580R User s Manual
Multi-Purpose, High Speed Centrifuge 1248R/1580R User s Manual Gene Company Limited 8/F., Shell Industrial Building, 12 Lee Chung Street, Chai Wan, Hong Kong Tel:(852)-2896-6283 Fax:(852)-2515-9371 info@genehk.com
More informationBio Lion CENTRIFUGES.
Bio Lion CENTRIFUGES www.bio-lion.com Table of Contents Refrigerated High Speed Centrifuge Page 1-3 Refrigerated Low Speed Centrifuge Page 4 High Speed Centrifuges Page 5 - Page 8 Low Speed Centrifuges
More informationVetlab CombiSpin Centrifuge
Vetlab CombiSpin Centrifuge User Manual 26.10.2017 Vetlab Supplies Ltd Unit 13 Broomers Hill Park Broomers Hill Lane Pulborough RH20 2RY Telephone: 01798 874567 Fax: 01798 874787 Email: info@vetlabsupplies.co.uk
More informationL550 Table-Top Low-Speed Large Capacity Centrifuge
L550 Table-Top Low-Speed Large Capacity Centrifuge Operational Manual Madell Technology Corp. http://www.madelltech.com 1. Model and name: L550 Table-top low-speed large capacity centrifuge. 2. Application:
More informationOperation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.
Concorde Liquid Handling Equipment Pipette Aid Operation Manual Cat. no. R14-PANAID *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version
More informationSystem 3 ZB1PS Device Chassis. Operator s Manual
System 3 ZB1PS Device Chassis Operator s Manual System 3 ZB1PS Operator's Manual Copyright 2007 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or transmitted
More informationFluorescent Ring Light with Dimmer INSTRUCTIONS
Fluorescent Ring Light with Dimmer INSTRUCTIONS Introduction Thank you for choosing Impact. The Impact Fluorescent Ring Light with Dimmer is a continuous light for photography and video. It casts a soft,
More informationMultistage Air Filtration Systems Instruction Manual
Multistage Air Filtration Systems Instruction Manual Be sure to read through this manual for proper use and safety. You must be familiar with the Safety Instructions before using this product. Please keep
More informationOPERATING INSTRUCTIONS
CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7
More information1100W PORTABLE GENERATOR
1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use
More informationInstruction Manual. CORDLESS DRILL 18V Li-ion WITH IMPACT FUNCTION. Model SROM 1172
Instruction Manual CORDLESS DRILL 18V Li-ion WITH IMPACT FUNCTION Model SROM 1172 Our tool range has you covered for DIY. Whatever the job, make light work of it with MAKO tools. Product Features: 1. Keyless
More informationCappController Pipette Controller. Operation Manual Version: 1.2.
CappController Pipette Controller Operation Manual Version: 1.2 www.capp.dk Table of Content 1. Safety Precautions... 1 2. General Description... 2 3. Getting Started... 3 3.1. Recharging the Battery...
More informationOPERATING INSTRUCTION
11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More information