1 Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai- Ph: + Fax: info@intechchennai.com Website: Temperature Controllers ECS CSM_ECS_DS_E Simple Functi ons in DIN mm-size Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for applications requiring alarms. Universal-input (thermocouple/platinum resistance thermometer) models also available. Clearly visible digital display with character height of. mm. RoHS compliant. Refer to Safety Precautions for All Temperature Controllers. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to ECS/ECSV Operation for operating procedures. Model Number Structure Model Number Legend Models U-W. Control Outputs R: Relay Q: Voltage for driving SSR. Alarm Outputs Blank: No alarm : alarm : alarms A functional explanation is provided here fo r illustration, but models are not necessarily available for all possible combinati ons. Refer to Ordering Information when ordering. Examples Relay control output, without alarm, thermocouple input,. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input) plug-in construction, light gray case: ECS-RKJU-W. Power Supply Voltage Blank: to VAC D: VAC/VDC. Terminal Shape U:. Case Color W: Light gray Relay control output, one alarm output, platinum resistance thermo meter input, plug-in construction, light gray case: ECS-RPU -W
2 Ordering Information ECS List of Models Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: to VAC Size Type Control modes ECS-U mm ON/OFF or PID Alarms Outputs Model with thermocouple Model with platinum resistance thermometer Relay ECS-RKJU-W ECS-RPU-W Voltage (for driving SSR) ECS-QKJU-W ECS-QPU-W Relay ECS-RKJU-W ECS-RPU-W Voltage (for driving SSR) ECS-QKJU-W ECS-QPU-W Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: VAC/VDC Size Type Control modes ECS-U mm ON/OFF or PID Alarms Outputs Model with thermocouple Model with platinum resistance thermometer Relay ECS-RKJDU-W ECS-RPDU-W Voltage (for driving SSR) ECS-QKJDU-W --- Relay ECS-RKJDU-W ECS-RPDU-W Voltage (for driving SSR) ECS-QKJDU-W --- Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: to VAC Size Type Control modes ECS-U mm ON/OFF or PID Alarms Outputs Model with thermistor Model with universalinput (thermocouple and platinum resistance thermometer) Relay ECS-RGU-W ECS-RTU-W Voltage (for driving SSR) ECS-QGU-W ECS-QTU-W Relay ECS-RGU-W ECS-RTU-W Voltage (for driving SSR) ECS-QGU-W ECS-QTU-W Relay --- ECS-RTU-W (See note.) Voltage (for driving SSR) ECS-QTU-W There is no alarm output mode switch. The default setting for alarm output is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output in initial setting level. For details, refer to the ECSV/ECS-U Digital Temperature Controller User s Manual (Cat. No. H-E-). Case Color: Light Gray, Thermistor, Power Supply Voltage: VAC/VDC Size Type Control modes ECS-U mm ON/OFF or PID Alarms Outputs Model with thermistor Relay ECS-RGDU-W ECS-RGDU-W Accessories (Order Separately) Socket without Alarm ( Pins) Socket with Alarm ( Pins) Type Front Connecting Socket Back Connecting Socket (flush mounting) Front Connecting Socket (with finger protection) Finger Safe Terminal Cover for PG Model PCF- PG- PCF--E YA-G Type Front Connecting Socket Back Connecting Socket (flush mounting) Front Connecting Socket (with finger protection) Finger Safe Terminal Cover for PG Model PCF- PGA- PCF--E YA-G Protective Cover Type Hard Protective Cover Model YA-B
3 Specifications ECS Ratings Supply voltage to VAC, / Hz VAC, / Hz; VDC Operating voltage range % to % of rated supply voltage Power consumption to VAC: VA VAC: VA, VDC: W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt, JPt Thermistor: E-THE@@ Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U, N, R, Pt, JPt Control Relay output SPDT, VAC, A (resistive load) output Voltage output (for driving the SSR) VDC, ma (with short-circuit protection circuit) Control method ON/OFF or -PID (with automatic PID parameter setting function) Alarm output SPST-NO, VAC, A (resistive load) Setting method Digital setting using front panel keys Indication method -segment digital display (character height:. mm) and deviation indicators Other functions Setting change prohibit (key protection) Input shift Temperature unit change ( C/ F) Direct/reverse operation Temperature range, Sensor switching (K/J/L, Pt/JPt) Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models. Control period switching -mode alarm output Sensor error detection (excluding thermistor models) Ambient operating to C (with no condensation or icing); with -year guarantee: to C temperature Ambient operating humidity % to % Storage temperature to C (with no condensation or icing) Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.)
4 Characteristics Setting accuracy Thermocouple (See note.): (±% of indication value or ± C, whichever is greater) ± digit max. Indication accuracy Platinum resistance thermometer (See note.): (±.% of indication value or ± C, whichever is greater) ± digit max. (ambient temperature of C) Thermistor (See note.): (% FS of indication value) ± digit max. Influence of temperature R thermocouple inputs: (±% of PV or ± C, whichever is greater) ± digit max. Influence of voltage Other thermocouple inputs: (±% of PV or ± C, whichever is greater) ± digit max. Platinum resistance thermometer inputs: (±% of PV or ± C, whichever is greater) ± digit max. Thermistor: (±% FS) ± digit max. Hysteresis (for ON/OFF control) Proportional band (P) Integral time (I) Derivative time (D).% FS (.% FS for universal-input (thermocouple/platinum resistance thermometer) models) to C (automatic adjustment using auto-tuning/self-tuning) to, s (automatic adjustment using auto-tuning/self-tuning) to, s (automatic adjustment using auto-tuning/self-tuning) ECS Alarm output range Absolute-value alarm: Same as the control range Other: to input setting range full scale ( C or F) Alarm hysteresis:. C or F (fixed) Control period / s Sampling period ms Insulation resistance MΩ min. (at VDC) Dielectric strength, VAC, / Hz for min between current-carrying terminals of different polarity Vibration Malfunction to Hz, m/s for min each in X, Y, and Z directions resistance Destruction to Hz,.-mm single amplitude for hr each in X, Y, and Z directions Shock resistance Malfunction m/s min., times each in six directions Destruction m/s min., times each in six directions Life expectancy Electrical, operations min. (relay output models) Weight Approx. g (Controller only) Degree of protection Front panel: Equivalent to IP, Enclosure Category (IEC ), Rear case: IP; Terminals: IP Memory protection EEPROM (non-volatile memory) (number of writes:,,) EMC EMI Radiated: EN Group Class A EMI Conducted: EN Group Class A Radiated Electromagnetic Field Immunity: EN --: kv contact discharge (level ) kv air discharge (level ) RF-interference Immunity: EN --: V/m (- MHz,.-. GHz amplitude modulated) (level ) V/m ( MHz pulse modulated) Conducted Disturbance Immunity: EN --: V (. to MHz) (level ) Noise Immunity (First Transient Burst Noise): EN -- Burst Immunity: kv power-line (level ), kv I/O signal-line (level ) Surge Immunity: EN --: Power line: Normal mode kv; Common mode kv Output line (relay output): Normal mode kv; Common mode kv Voltage Dip/Interrupting Immunity: EN --. cycle, % (rated voltage) Approved standards UL - (listing) CSA C. No.- Conformed standards EN, EN -, IEC -. The following exceptions apply to thermocouples. U, L: ± C ± digit max. R: ± C ± digit max. at C or less. The following exception applies to platinum resistance thermometers. Input set values for ECS-U: % FS ± digit max.. The following exceptions apply to thermistors. When the unit setting is C, temperature indication ranges exceeding the set temperature range ±% FS may not be accurate. When the unit setting is F, the temperature range for the input setting numbers and ( to F) and temperature indication ranges exceeding the set temperature range % FS to +% FS may not be accurate.
5 Temperature Range Thermocouple Input Models Temperature range using switch) (Default setting: ) Input K J/L, Setting number Minimum setting unit C C Platinum Resistance Thermometer Input Models Temperature range using switch) Input.. JPt/Pt.... (Default setting: ) Setting number Minimum setting unit C. C C. C C. C ECS Thermistor Input Models (For details on Sensors, refer to E.) Temperature range using switch) Input kω ( C) kω ( C) kω ( C) Universal-input (Thermocouple/Platinum Resistance Thermometer) Models Using Thermocouple Sensors, Control Mode Switch : OFF Using Platinum Resistance Thermometers, Control Mode Switch : ON G Ω kω ( C) ( C) kω ( C) kω ( C) kω ( C) Ω kω ( C) ( C) (Default setting: ) Setting number Minimum setting unit C Input K J L T U N R,,,,,,, Temperature, range,,, using switch) (Default setting: ) Setting number Minimum setting unit C. C C. C C. C C Temperature range using switch) (Default setting: ) Input Pt JPt,.... Setting number Minimum setting unit C. C C. C C
6 External Connection Diagram ECS models Sensor Thermocouple (See note.) Platinum resistance thermometer (See note.) Without alarms Thermistor Voltage output models (See note.) Voltage output models (See note.) Voltage output models (See note.) VDC, ma Voltage output VDC, ma Voltage output VDC, ma Relay output models Relay output models Relay output models Voltage output With alarms (K, J) Voltage output models (See note.) to VAC VAC/VDC (See note.) Two alarm points B A B Voltage output models (See note.) to VAC VAC/VDC (See note.) Two alarm points Voltage output models (See note.) to VAC VAC/VDC (See note.) VDC, ma OUT VDC, ma OUT VDC, ma OUT Alarm output Alarm output Alarm output Alarm output Relay output models Relay output models Relay output models Alarm output Alarm output Alarm output to VAC VAC/VDC (See note.) B A B to VAC VAC/VDC (See note.) to VAC VAC/VDC (See note.). The voltage output ( VDC, ma) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals or to ground. Otherwise, unwanted current paths will cause measurement errors.. Models with to VAC and VAC/VDC are separate. Models using VDC have no polarity.. Be sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models. Nomenclature ECS-U Models Temperature display Deviation indicators Mode indicators Mode Key Output indicator Alarm indicators Up Key Down key
7 Dimensions ECS All units are in millimeters unless otherwise indicated. Controller ECS-U Terminal Arrangement (Bottom View) (.)..... Models without alarms Models with alarms Panel Cutout Dimensions The external dimensions are the same for both models with and without alarms L min. + L = ( N.) Mounting side-by-side (group mounting of N Controllers) ECS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (Without Alarms) Adapter for flush mounting Panel YF- Adapter for flush mounting PG- Back Connecting Socket Tightening screws ECS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (With Alarms) Adapter for flush mounting Panel YF- Adapter for flush mounting PGA- Back Connecting Socket Tightening screws Use the PCF- and PG- Sockets for models without alarms, and use the PCF- and PGA- Sockets for models with alarms.
8 Accessories (Order Separately) -pin Sockets without Alarms PCF- Front Connecting Socket max. Eight, M.. sems screws. Two,.-dia. holes.. Terminal Arrangement/ Internal Connections (Top View) ±. ECS Mounting Hole Dimensions Two,.-dia. hole or two, M DIN Track mounting is also possible. max.. max. The PCF--E Socket with finger protection is also available. PG- Back Connecting Socket dia. Terminal Arrangement (Bottom View). M. The YA-G Finger Safe Terminal Cover is also available. -pin Sockets with Alarms PCF- Front Connecting Socket max. Eleven, M.. sems screws. Two,.-dia. holes.. Terminal Arrangement/ Internal Connections (Top View) Mounting Hole Dimensions Two,.-dia. mounting holes ±. DIN Track mounting is also possible. max.. max. The PCF--E Socket with finger protection is also available. PGA- Back Connecting Socket dia. Terminal Arrangement (Bottom View)..... The YA-G Finger Safe Terminal Cover is also available. Do not use any other types of Sockets. Doing so will adversely affect the accuracy. Applicable Thermistors Use Element Interchangeable T hermistors (E-THEA, E- THED, and E-THEF) to connect to the For details on Sensors, refer to E. Hard Protective Cover The YA-B Hard Protective Cover is available for the following applications. To protect the set from dust and dirt. To prevent the panel from being accidentally touched c ausing displacement of set values. To provide effective protection against water droplets. Authorised Distributors:- Intech Systems Chennai Pvt. Ltd S-, Guindy Industrial Estate, Chennai- Ph: + Mob: Fax: info@intechchennai.com Website: A-B
E5CSV temperature controller
ECSV temperature controller R e a d y, s e t, g o!» P e r f e c t c o n t ro l» Easy setting u p» E n h a n c e d f u n c t i o n a l i t y Advanced Industrial Automation Perfect temperature control in
More informationTemperature Controllers
Temperature Controllers ECSV Easy Setting Using DIP Switch and Simple Functions in DIN 8 8 mm-size Temperature Controllers Easy setting using DIP and rotary switches. Models with two alarms added to Series,
More informationTemperature Controllers
Temperature Controllers ECSZ Easy Setting Using DIP Switch and Simple Functions in DIN 8 8 mm-size Temperature Controllers Easy setting using DIP and rotary switches. Models with two alarms added to Series,
More informationSurface mounting, flush mounting, and DIN track mounting
Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,
More information0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)
Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and
More informationDigital Temperature Controller
Digital Temperature Controller Compact and Intelligent 1/32 DIN Temperature Controller with Communications Function Auto-tuning and self-tuning available. Can auto-tune even during execution of self-tuning
More informationCommunications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.
Modular Temperature Controller New In-panel DIN Track Mounting Temperature Controller Ordering Information RC : : Name Temperature Controller Terminal Unit Power supply 24 VDC 2 No. of control points Control
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More information1/16 DIN Temperature Controller E5CS
1/16 DIN Temperature Controller Automatic Adjustment and ID Control in a 48x48-mm ackage Control accuracy to ±1% of full scale Selectable temperature ranges in C or F Easy-to-read 13.4-mm high LED display
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More informationPCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A
PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance
More informationInductive Proximity Sensor
Inductive Proximity Sensor E2Q3 Square Proximity Sensor Terminal housing Integrated short circuit and reverse polarity protection Output function programmable by wiring Active face positioning: Y-axis
More informationOrdering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1
Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out
More informationTemperature Controllers E5CSV
Temperature Controllers ECSV Simple to Set and Operate / DIN Size Controllers Easy setting using internal DIP and rotary switches / or PID control (with on-demand auto-tuning) selectable Clearly visible
More informationInsulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit
SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,
More informationH3DS-X - Solid State Two-Wire Timer
OMRON Analog Set Multifunction Timers H3DS Series To view data sheets, click on any link below: H3DS - Standard Timer H3DS-F - Twin Timer H3DS-G - Star-Delta Timer H3DS-X - Solid State Two-Wire Timer Multi-function
More informationHigh-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.
Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available
More informationAnalog Input Terminal
Analog Input Terminal I/O Interface Converts Analog Input Data into Binary Data Four inputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion
More informationType Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed
PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands
More informationType Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US
Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations Class 1 Division 2 approved. Fully hermetically sealed for hazardous locations. Cadmium-free contacts for environment-friendly
More informationAnalog Output Terminal
Analog Output Terminal I/O Interface Converts Binary Data into Analog Output Data Two outputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion
More informationDescription General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance
R High-Precision Fiber-optic Amplifier TheEmploysa16-Bit Processor as An Industry First H An Automatic Sensitivity Adjustment feature allows stable detection of objects in frequently changing environments
More informationApplicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL
Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent
More informationOrdering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays
Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil
More informationApplication Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from
Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00
More informationModel Number Structure
Solid State Relays CSM DS_E_2_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible
More informationLoad Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC
Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30
More informationG9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect
Two-Hand Controller -mm Wide Two-hand Control Circuit H Two-hand Controller, easy-to-connect Expansion Units available H Positive, force-guided contacts H DIN-rail mounting and panel mounting available
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationModel Number Structure
Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can
More informationModel Number Structure
Solid State Relays Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking
More information* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.
Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor
More informationPCB Relay. Contact form Terminal Single-side stable Single-winding latching
PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving
More informationD4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationPre-wired Models D4C- (1) (2) (3) (4)
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 03 Ph: +91 44 4353 Fax: 044 4353 E-mail: info@intechchennai.com Website: www.intechchennai.com Enclosed Switch D4C CSM_D4C_DS_E_10_1
More informationD4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.
Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety
More informationD2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend
Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationEmergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm
Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418
More informationModel Pressure range ON/OFF output Linear output
Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention
More informationModel Pressure range ON/OFF output Linear output
Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor
More information20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24
Solid State Relays (SSRs) G3PA/G3PB Long Service Life for Circuits that Cycle Frequently D D D D D Built-in heat sink increases life and reliability Voltage turn-on at zero crossing reduces initial inrush
More informationModel Number Structure
Solid State Relays CSM OEE_DS_E_1_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting
More informationModel Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend
Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start
More informationSafety-door Switch. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.
More informationOrdering Information. Text PCB Power Relay G5LE
A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms
More informationTransistor Remote Modules
Transistor Remote Modules Compact 8-point and 16-point Transistorized Modules Compact (8-point models: 125 x 40 x 50 mm (W x H x D); 16-point models: 150 x 40 x 50 mm (W x H x D)) Two independent supplies
More informationDigital display Pressure range ON/OFF output Linear output Model
Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be
More informationOrdering Information. Text Surface-Mounting Signal Relay G6K
Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.
More informationSYSMAC Transistor Remote Module
9 SYSMAC Transistor Remote Module Block and Transmission Capability in One Module 1 Two-conductor cable communications available using Omron Wired Remote I/O Master Modules (C200H-RM201 and C500-RM201)
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition
More informationPCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment
PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.
More informationG7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press
Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms
More informationOrdering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31
Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision
More informationType Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g
Tactile Switch BF Miniature, Space-Saving Tactile Switch Provides Long Service Life and Easy Mounting Extended mechanical/electrical service life: 0 x 0 6 operations for x mm type and x 0 6 operations
More informationPressure transmitters for heavy duty applications MBS 8200 and MBS 8250
Data sheet Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known
More information24-hour/Weekly Time Switch H2F
24-hour/Weekly Time Switch H2F Up to 96 ON/OFF Cycles from DIN-sized (72 x 72 mm) Timer Easy setting with color-coded programming tabs. Choose from 24-hour or 1-week models with either SPST-NO or SPDT
More informationSolid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations
Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage
More informationTL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information
Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page
More informationA22NK. Key-type Selector Switches
Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy
More informationSubminiature Basic Switch
Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000
More informationD4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.
Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN (TÜV) standards. (positive opening mechanism isindicatedonthe switch) H Wide standard operating
More informationModel Number Structure
Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive
More informationEnclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models
Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with
More informationG7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets
Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes
More informationPower Controller. (see note 1) 10 sec
Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control
More informationPCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC
PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through
More informationPCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal
PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with
More informationSwitching Power Supply
Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels
More informationPCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S
PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and
More informationModel Number Structure
Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action
More informationInductive Proximity Sensor
Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED
More informationG3PE-Single-phase. Solid State Relays for Heaters
Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with
More informationApplication Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from
Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00
More informationA165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm
Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts
More informationPCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable
PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and
More informationD4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.
Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation
More informationG7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend
A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationSwitching Power Supply
Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote
More informationM5200 Industrial Pressure Transducer
SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof Gage, Sealed, Compound The pressure
More informationInput terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model
Solid State Relays with Built-in Current Transformer CSM DS_E_7_ A New-concept SSR with Built-in Current Transformer. Heater Burnout and SSR Shortcircuit Failure Detection. Built-in Current Transformer
More informationIntrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure
Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable
More informationD4DL. Guard Lock Safety-door Switch. Model Number Structure
Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied
More informationDigital Pressure Sensor
Digital Pressure Sensor SALIENT FEATURES IP 65 enclosure Hysteresis Adjustable Programmable Pressure unit Dual Digital & Voltage Outputs Wide measurement range 1~10 bar Model Number Legend 1 2 3 4 1. Series
More informationD4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -
Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head
More informationOrdering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings
Motor Time Switch H2F-WM CSM_H2F-WM_DS_E_2_1 Weekly ON/OFF Control in 1-h Increments The H2F-WM is a Compact Weekly Time Switch in a DIN -mm Body Equipped with Power Interruption Backup Providing Protection
More informationManual Reset Limit Switch
Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
Emergency Stop Devices A22E A22E For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Emergency Stop Switch (22 mm or 25
More informationMicro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES
MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...
More informationE2EZ-X2D1-N E2EZ-X2D2-N
Chip-immune Inductive s Detects Objects without Being Influenced by Aluminum or Iron Chips Series now includes M s. s also available. CE Marking for DC -Wire and DC -Wire s. Be sure to read Safety Precautions
More informationSmall Limit Switch D4V
Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully
More informationSolid State Relays contactor with Integrated Fuse Type RGC1F
Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC
More informationAC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A
Main Feature 1. 1 Pole to 4-Poles versions available with switching current at 15A (1 Pole) and 10A (2-4 Poles). 2. Printed Circuit Board Terminal, Plug-in Terminal and Flanged Case are designed for easy
More informationPCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC
PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationOrdering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES
Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak
More information