IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627

Size: px
Start display at page:

Download "IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627"

Transcription

1 MODULOSTAR CMS4, CMS IEC fuse holders: CMS 4 - Fuse holder compliant with IEC 09- &, and tested in accordance with IEC & for fuse disconnector usage IEC fuse disconnectors: CMS 4 - Fuse disconnectors compliant with IEC & and Electrical characteristics insulation Ui AC/DC V AC B impulse withstand Uimp current Max. power dissipation per fuse 8 kv A W CMS 4 fuse holders for 4x fuses without striker Poles N + N + N 4 Fuse holders without indicator light CMS4N CMS4 CMS4N CMS4 CMS4 CMS4N CMS44 Ref.Num N48 F9 E J J9 L8 G4 Mod. (7. mm).. Fuse rating * Values shown for C ambient temperature. IEC 09- & Maximum current in use for,, et +N poles with FS-fuses. for 4, and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. gg am URD - URC URGA URGB grb glb Wiring: Rigid wire =. - mm ( - AWG) - Multistrand wire: Maximum mm (4 AWG) Tightening torque:. Nm max / 0 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat. x mm (maximum diameter mm). Poles + N + N CMS4I CMS4NI CMS4I CMS4I CMS4NI M0778 M8 C79 Z D7 8 0 Fuse holders with indicator light Ref.Num Mod. (7. mm) Recommended wire cross-section (mm ) for 4x fuses with striker Standard ready for accessories Mod. Possible Functions Pole Ref.Num (7. mm) L4 CMS4AC. Indicator light & blown fuse only CMS 4 fuse disconnectors for all types of 4x fuses Pole N N48. CMS4P P7708 CMS4M K44 CMS4MI N87. + N P49 * CMS4P G99 CMS4M R7 CMS4MI K7 consult us CMS4P N0779 CMS4M T CMS4MI D80 * CMS4M Y8 CMS4MI K9 + N CMS4NP F4 CMS4NM L799 CMS4NMI A 4 * Two auxiliary (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers. Accessories 07/0 Model without indicator Model with indicator light Model fitted with light ready for accessories ready for auxiliary microswitch auxiliary microswitch Ref.Num Description Auxiliary microswitch kit pole CMS 4 Auxiliary microswitch kit poles CMS 4 auxiliary microswitch kit poles CMS 4 Auxiliary microswitch assembly pin (between kits) Enlargement pin for auxiliary microswitch Multi-pole assembly kit Indicator light kit Lock Model fitted with auxiliary microswitch & indicator light CMS4W CMS4W CMS4W CMS4PTH CMS4BP CMS4PAK CMS4LHI LOCK FG4 References M874 C9 D979 J48 F9 Z8 A M Mod. (7. mm) Mod. (7. mm). 0* 0* 0* * 0 per bag Auxiliary microswitch kit M874 Enlargement pin for auxiliary microswitch - F9 Auxiliary microswitch assembly pin J48

2 MODULOSTAR CMS4, CMS IEC fuse holders: CMS - Fuse holder compliant with IEC 09- &, and tested in accordance with IEC & for fuse disconnector usage IEC fuse disconnectors: CMS - Fuse disconnectors compliant with IEC & and Electrical characteristics insulation Ui AC/DC V AC B impulse withstand Uimp current Max. power dissipation per fuse 8 kv A 9. W CMS fuse holders for x8 fuses without striker Poles N + N + N 4 Fuse rating CMSN CMS CMSN CMS CMS CMSN CMS4 Accessories Maximum current in use for,, et +N poles with FS-fuses. for 4, and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. gg am URD - URC URGA URGB grb glb * Values shown for C ambient temperature. Wiring: Rigid wire =. - mm ( - AWG) - Multistrand wire: Maximum mm ( AWG). Tightening torque: max. Nm - 4 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat. x. mm (maximum diameter 7 mm). Auxiliary microswitch kit E8 G D9 Enlargement pin for auxiliary microswitch - F9 Auxiliary microswitch assembly pin - J48 Pole N + N * + N Ref.Num M9 E8 L44 V Z8 Q7709 N Fuse holders without indicator light Model without indicator light ready for accessories CMSN M9 CMSP G CMSNP M447 CMSP T9 CMSP W7 W7 CMSNP A77 Mod. (7. mm) for x8 fuses with striker Pole Standard ready for accessories IEC 09- & Mod. (7. mm) consult us Model with indicator light ready for auxiliary microswitch CMSM * Two auxiliary (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers. Description Auxiliary microswitch kit pole CMS Auxiliary microswitch kit poles CMS auxiliary microswitch kit poles CMS Auxiliary microswitch assembly pin (between kits) Enlargement pin for auxiliary microswitch Multi-pole assembly kit Indicator light kit Lock 9 0 CMSM CMSM CMSM CMSNM Poles + N + N Model fitted with auxiliary microswitch D9 E979 Q470 H99 P0780 FG44 * 0 per bag 07/0 9 7 CMSI CMSNI CMSI CMSI CMSNI CMSMI 7 8 H47 S8 Z7 M70 A84 CMSAC P88. Indicator light & blown fuse only CMS fuse disconnectors for all types of x8 fuses Fuse holders with indicator light Model fitted with auxiliary microswitch & indicator light A8 CMSMI N7 CMSMI R770 CMSMI B8 CMSNMI P874 CMSW CMSW CMSW CMS4PTH CMS4BP CMS4PAK CMS4LHI LOCK Ref.Num Possible Functions References E8 L9 B J48 F9 Z8 A M Mod. (7. mm). Recommended wire cross-section (mm ) Mod. (7. mm).. Mod. (7. mm) * 0* 0*

3 MODULOSTAR CMS4, CMS Mecanics for CMS/US 4 & Dimensions of CMS 4 and US 4 products Width depending Nb poles 4 on nb. of 7. mm modules modules mm Dimensions of CMS and US products Width depending Nb poles 4 on nb. of 7. mm modules modules mm /0 FG4

4 MODULOSTAR CMS4, CMS Locking system Mecanics for CMS/US 4 & Locking reference: M Multipole assembly Assembly kit CMS4 & CMS : Z8 Assembly kit US 4: X797 US : F798 Each bag of kits is sufficient for: 0 multipole assemblies 0 two-pole assemblies three-pole assemblies NB: poles maximum in an assembly Mounting auxiliary four-pole assemblies Dismounting auxiliary Auxiliary microswitch functions Characteristics of the auxiliary microswitch MICRO Fuse melting: A fuse holder containing a fuse with a striker sends out a signal when the fuse element melts Min. and current for operation 0VAC-DC - 00mA current A AC and breaking capacity () at 0V A AC 0,A AC 4 0,A DC //4 M Pre-isolation: Presence: When the fuse holder opens Sends a signal when the holder is closed with no fuse in it current and breaking A DC /DC capacity () at and 4 V A AC A AC 4/DC 0,A DC 4 () as per standard IEC 947- With the fuse in the handle closed state. No fuse Fuse blown Handle open FG4 07/0

5 MODULOSTAR CMS4, CMS Mecanics for CMS/US 4 & Microswitch options Auxiliary can only be mounted on previously prepared fuse disconnectors. Use of the auxiliary microswitch for fuse melting requires the use of fuses with strikers. auxiliary microswitch CMS 4 (C9) - US4 (Z799) CMS (L9) - US (H7) or auxiliary microswitch CMS 4 (M874+F9) CMS (E8+F9) US 4 (Y798+F9) US (G979+F9) auxiliary CMS 4 (D979) - US4 (A7) CMS (B) - US (J79) independent auxiliary CMS 4 ( x M874) CMS ( x E8) US 4 ( x Y798) US ( x G799) mechanically interconnected auxiliary CMS 4 ( x M874+ x J48) CMS ( x E8+ x J48) US 4 ( x Y798) + ( x J48) US ( x G799) + ( x J48) NOTE: Do not fit with more than Supply wiring bars and terminals Description jumping bar for 4 (CMS 4/US 4) poles jumping bar for (CMS 4/US 4) poles jumping bar for (CMS 4/US 4) pole jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole Single-pole terminal, side /-pole terminal, side Single-pole terminal, axial /-pole terminal, axial ber CMS4BBF4 CMS4BBF CMS4BBF CMSBBF CMSBBF TBBC TBBC TBBA TBBA Ref. Number A Z Y0 C4 B E G8 D F7 Maximum acceptable RMS current (A) 00 07/0 FG47

6 MODULOSTAR CMS4, CMS With the indicator light a blown fuse can be quickly located if power is still on Indicator light kit Carefully remove the cover with screw drivers. Slip the indicator light s top insert into the rails, being careful not to twist the contact tabs. Put the cover back on Assembly precautions in multipole assemblies When fuse holders are side by side or very near each other (less than one module apart), they must be derated again, in addition to derating for temperature Number of 7. mm modules > 0 Derating factor None = FG48 /04

7 MODULOSTAR US4, US UL fuse holders: US 4 Fuse holder compliant with IEC09- &, and tested in accordance with IEC & for fuse disconnector usage. Electrical characteristics insulation Ui AC/DC impulse withstand Uimp current Max. power dissipation per fuse Fuse rating 7 V 8 kv A 4,7 W 0 * Values shown for C ambient temperature. gg 0 Maximum current in use for,, et +N poles with FS-fuses. for 4, and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. 0gD am URD - URC URGA URGB grb glb Wiring: Rigid wire =. - mm ( - AWG) - Multistrand wire: Maximum mm (4 AWG) Tightening torque:. Nm max / 0 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat. x mm (maximum diameter mm) Recommended wire cross-section (mm ) 4 ULTRASAFE TM US 4 fuse disconnectors for 4x fuses with no striker, or with indicator light or with striker Recognized compliant with UL and CSA -, IEC &, and IEC 09- & Pole N + N * * + N + N* 4 4* Model without indicator light ready for accessories US4N US4 US4N US4 US4 US4N US44 Ref.Num S70 T7 Y7 C79 J79 Q79 Model with indicator light ready for auxiliary contact US4I US4NI US4I US4I US4NI US44I V7 Z7 D7 K79 R79 Model fitted with auxiliary contact US4M US4NM US4M US4M US4M US4M US4NM US4NM US44M US44M W7 A77 E79 G79 L797 N799 S79 V79 Model fitted with auxiliary contact & indicator light US4MI US4NMI US4MI US4MI US4MI US4MI US4NMI US4NMI US4MI US44MI X74 B78 F79 H794 M798 P79 T794 W79 Mod. (7. mm) * Two auxiliary (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers.. X74 Accessories Description Auxiliary contact kit pole US 4 Auxiliary contact kit poles US 4 auxiliary contact kit poles US 4 Auxiliary contact assembly pin (between kits) Enlargement pin for auxiliary contact Multi-pole assembly kit Indicator light kit Lock USMSW USMSW USMSW US4PTH US4BP US4PAK CMS4LHI LOCK References Y798 Z799 A7 J48 F9 X797 A M Mod. (7. mm). 0* 0* 0* * 0 per bag Auxiliary contact kit Y798 Enlargement pin for auxiliary contact - F9 Auxiliary contact assembly pin J48 07/0 FG49

8 MODULOSTAR US4, US Electrical characteristics insulation Ui AC/DC impulse withstand Uimp current Max. power dissipation per fuse 7 V 8 kv A 9. W UL fuse holders: US Fuse holder compliant with IEC09- &, and tested in accordance with IEC & for fuse disconnector usage. Fuse rating - 0/ * Values shown for C ambient temperature. gg 0 Maximum current in use for,, et +N poles with FS-fuses. for 4, and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. 0gD am URD - URC URGA URGB grb glb Wiring: Rigid wire =. - mm ( - AWG) - Multistrand wire: Maximum mm ( AWG). Tightening torque: max. Nm - 4 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat. x. mm (maximum diameter 7 mm). 0 ULTRASAFE TM US fuse disconnectors for x8 fuses with no striker, or with indicator light or with striker Recognized compliant with UL and CSA -, IEC &, and IEC 09- & F79 C79 Pole N + N * * + N + N* 4 4* Model without indicator light ready for accessories USN US USN US US USN US4 Ref.Num B79 C79 G79 L79 S794 Z Model with indicator light ready for auxiliary contact USI USNI USI USI USNI US4I D79 H797 M794 T7947 A79 * Two auxiliary (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers Model fitted with auxiliary contact USM USNM USM USM USM USM USNM USNM US4M US4M E794 J798 N794 Q7944 V7948 X79 B794 D Model fitted with auxiliary contact & indicator light USMI USNMI USMI USMI USMI USMI USNMI USNMI USMI US4MI F79 K799 P794 R794 W7949 Y79 C79 E797 Recommended wire cross-section (mm ) Mod. (7. mm).../ 4/0 /0 0/8 0/8 0/8 / /4 / / Accessories Auxiliary contact kit Y798 Enlargement pin for auxiliary contact - F9 Auxiliary contact assembly pin J48 Description Auxiliary contact kit pole US Auxiliary contact kit poles US auxiliary contact kit poles US Auxiliary contact assembly pin (between kits) Enlargement pin for auxiliary contact Multi-pole assembly kit Indicator light kit Lock USMSW4 USMSW USMSW US4PTH US4BP USPAK CMS4LHI LOCK References G799 H7 J79 J48 F9 F798 A M Mod. (7. mm). 0* 0* 0* * 0 per bag FG0 07/0

9 MODULOSTAR US4, US Mecanics for CMS/US 4 & Dimensions of CMS 4 and US 4 products Width depending Nb poles 4 on nb. of 7. mm modules modules mm Dimensions of CMS and US products Width depending Nb poles 4 on nb. of 7. mm modules modules mm /0 FG

10 MODULOSTAR US4, US Locking system Mecanics for CMS/US 4 & Locking reference: M Multipole assembly Assembly kit CMS4 & CMS : Z8 Assembly kit US 4: X797 US : F798 Each bag of kits is sufficient for: 0 multipole assemblies 0 two-pole assemblies three-pole assemblies NB: poles maximum in an assembly Mounting auxiliary four-pole assemblies Dismounting auxiliary Auxiliary microswitch functions Characteristics of the auxiliary microswitch MICRO Fuse melting: A fuse holder containing a fuse with a striker sends out a signal when the fuse element melts Min. and current for operation 0VAC-DC - 00mA current A AC and breaking capacity () at 0V A AC 0,A AC 4 0,A DC //4 M Pre-isolation: Presence: When the fuse holder opens Sends a signal when the holder is closed with no fuse in it current and breaking A DC /DC capacity () at and 4 V A AC A AC 4/DC 0,A DC 4 () as per standard IEC 947- With the fuse in the handle closed state. No fuse Fuse blown Handle open FG 07/0

11 MODULOSTAR US4, US Mecanics for CMS/US 4 & Microswitch options Auxiliary can only be mounted on previously prepared fuse disconnectors. Use of the auxiliary microswitch for fuse melting requires the use of fuses with strikers. auxiliary microswitch CMS 4 (C9) - US4 (Z799) CMS (L9) - US (H7) or auxiliary microswitch CMS 4 (M874+F9) CMS (E8+F9) US 4 (Y798+F9) US (G979+F9) auxiliary CMS 4 (D979) - US4 (A7) CMS (B) - US (J79) independent auxiliary CMS 4 ( x M874) CMS ( x E8) US 4 ( x Y798) US ( x G799) mechanically interconnected auxiliary CMS 4 ( x M874+ x J48) CMS ( x E8+ x J48) US 4 ( x Y798) + ( x J48) US ( x G799) + ( x J48) NOTE: Do not fit with more than Supply wiring bars and terminals Description jumping bar for 4 (CMS 4/US 4) poles jumping bar for (CMS 4/US 4) poles jumping bar for (CMS 4/US 4) pole jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole Single-pole terminal, side /-pole terminal, side Single-pole terminal, axial /-pole terminal, axial ber CMS4BBF4 CMS4BBF CMS4BBF CMSBBF CMSBBF TBBC TBBC TBBA TBBA Ref. Number A Z Y0 C4 B E G8 D F7 Maximum acceptable RMS current (A) 00 07/0 FG

12 MODULOSTAR US4, US With the indicator light a blown fuse can be quickly located if power is still on Indicator light kit Carefully remove the cover with screw drivers. Slip the indicator light s top insert into the rails, being careful not to twist the contact tabs. Put the cover back on Assembly precautions in multipole assemblies When fuse holders are side by side or very near each other (less than one module apart), they must be derated again, in addition to derating for temperature Number of 7. mm modules > 0 Derating factor None = FG4 /04

IEC fuse holders & fuse disconnectors: CMS 14

IEC fuse holders & fuse disconnectors: CMS 14 Modulostar CMS14, CMS22 Modulostar IEC fuse holders & fuse disconnectors: CMS 14 IEC fuse holders: CMS 14: Fuse holder compliant with IEC 60269-1 & 2, and tested in accordance with IEC 60947-1 & 3 for

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT.

Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT. MR 0 CI MR 0 MR - MR 0. Clips MR - MR 7 MR For Ferrule style Fuses ø 0 - - - 7 - SILVER-PLATED COPPER CLIPS: EXTREMELY HIGH THERMAL AND ELECTRIC CONDUCTIVITY MOUNTING TYPE: - SCREWING ON ISOLATORS - SCREWING

More information

Low voltage fusegear for cylindrical fuses. Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors

Low voltage fusegear for cylindrical fuses. Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors Low voltage fusegear for cylindrical fuses Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors FUSEGEAR FOR CYLINDRICAL FUSES Fusegear Needs and solutions IEC standard 947-

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

American Round Fuses - Form 101 range

American Round Fuses - Form 101 range Form 0 A5QS - 50 Vac A5QS- D007J 0 A5QS- E007J 0 A5QS- F0074J 0 4 A5QS4- G0075J 0 5 A5QS5- H007J 0 A5QS- J0077J 0 7 A5QS7- K0078J 0 8 A5QS8- L0079J 0 0 A5QS0- N008J 0 A5QS- P008J 0 5 A5QS5- Q008J 0 0 A5QS0-

More information

gg ferrule-style fuses

gg ferrule-style fuses gg 8.5 x 31.5-400V Size Current Voltage Cat. number Ref. number Cat. number Ref. number Voltage Ref. number Cat.number Pckg (A) (V) w/o indicator w/o indicator with indicator with indicator (V) with striker

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

ULTRASAFE Fuse Holders The safety evolution continues.

ULTRASAFE Fuse Holders The safety evolution continues. ULTRASAFE Fuse Holders The safety evolution continues. The Revolutionary Advantages Ferraz Shawmut continues to lead the safety evolution with even more improvements to our popular ULTRASAFE fuse holders.

More information

Semiconductor Fuses Microswitches & Studs

Semiconductor Fuses Microswitches & Studs MICROSWITCH SYSTEMS ADAPTED TO THE FOLLOWING FUSES: - PSC sizes 0,,, / 70, 7, 7, 7 - Blade-type PSC (PA) sizes 0-, - / 70, 7, 7, 7 - PSC sizes 000 / 00 New MS L -5 B6 MS PA -5 HIGHLY RESISTANT STUDS OFFERING

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

FERRAZ SHAWMUT IS NOW. Fuses Fusegear

FERRAZ SHAWMUT IS NOW. Fuses Fusegear FERRAZ SHAWMUT IS NOW Fuses Fusegear FOUR KEY ASSETS TO SERVE FIVE MARKETS As the global specialist in electrical and thermal protection for electrical equipment in industry, Ferraz Shawmut serves five

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw Modulostar Motor Branch 400V AC - 690V AC up to 11 kw Innovations in MODULOSTAR to control energy in motor starters Already active in the field of motor starters with rated current over 32A per phase,

More information

USCC & USM UltraSafe TM Fuseholders

USCC & USM UltraSafe TM Fuseholders USCC & USM UltraSafe TM Fuseholders UltraSafe modular fuseholders for midget and class CC fuses Mersen UltraSafe Modular Fuseholders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2

More information

Fusegear for Semiconductor Fuse

Fusegear for Semiconductor Fuse Fusegear for Semiconductor Fuse IP 20.SI Bases for PSC ranges: SI TT, SI 000/00, SI DIN SI TT for stud-type fuses SI 00 for bracket-type fuses STANDARD VERSION SI FUSEHOLDERS FOR STUD-TYPE FUSES, FOR BLADE-TYPE

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

TeSys GS. Data for Designers. Contents

TeSys GS. Data for Designers. Contents TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15 Characteristics -

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

G eneral Purpose Fuses

G eneral Purpose Fuses G eneral Purpose Fuses North American Power Fuses AMP-TRAP2000 AMP-TRAP2000 AJT Class J - Time Delay 1 to 600A - - Motor, motor controller, control transformer, and circuit back-up protection. Space saving

More information

Fuse Blocks & Holders

Fuse Blocks & Holders ULTRASAFE Fuse olders / USCC, USM & DC ULTRASAFE Fuse olders / USFM ULTRASAFE Fuse olders / US3J & US6J ULTRASAFE Fuse olders / US14 & US22 Fuse Blocks / Class J Space-Saving Fuse Blocks / SJ Series Fuse

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION: Fused CONTROL: Side control, padlockable in off position by three padlocks. Safe and reliable of contact position on handles. SWITCHING: Double isolation per phase. Complete isolation of fuse when circuit

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories ,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

fuse holders & bases

fuse holders & bases PMF Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, single-phase+neutral in only one module and multi-pole types. Available with fusing indicator

More information

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1)

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) THE COMMITMENT OF MERSEN IN SAFER AND MORE RELIABLE SOLAR PHOTOVOLTAIC INSTALLATIONS In the solar market Mersen is a driving force in the

More information

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Helio Protection.   Solar solutions designed by Ferraz Shawmut. Power generation & distribution. 1 Helio Protection Solar solutions designed by Ferraz Shawmut www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Fuse Blocks & Holders

Fuse Blocks & Holders Fuse Blocks & olders Finger-safe IEC, Traditional, Panel Mount... You name the block, we ve got it in stock. Your problem: You need a range of standard fuse blocks to meet industrial requirements. You

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

IEC Low Voltage Products Module 4

IEC Low Voltage Products Module 4 IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting

More information

TeSys GS & DF Fuse protection

TeSys GS & DF Fuse protection TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information